Test Report

FCC ID: U5Z-RB-TX10B

Test Report

Download: PDF
FCCID_4072358

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



                                                             FCC LISTED,
                                                             REGISTRATION NUMBER:
                                                             720267                              Test report No:

                                                             ISED LISTED                       NIE: 59091RRF.001
                                                             REGISTRATION NUMBER
                                                             ISED 4621A-4

          Test report
         USA FCC Part 15.249 & 15.209
         CANADA RSS-210, RSS-Gen
         Radio Frequency Devices. Operation within the bands 902 - 928 MHz,
         2400 -2483.5 MHz, 5725 - 5875 MHz, and 24.0 – 24.25 GHz.


           Identification of item tested                        Safety edge wireless system consisting in a transmitter


           Trademark                                            JCM


           Model and /or type reference                         RB-TX10B


           Other identification of the product                  FCC ID: U5Z-RB-TX10B
                                                                IC: 8572A-RBTX10B

           Features                                             Power supply: 3,6Vdc (2x3,6Vdc ER14505 AA)
                                                                Frequency: Multifrequency system 916MHz auto-
                                                                adjustable
                                                                Operating consumption: 12mA
                                                                Radiated power < 25mW
                                                                Range (in open field): 50m
                                                                Battery life (approximately): 2 years

           Applicant                                            JCM TECHNOLOGIES, S.A.
                                                                C/Morgades, 46 Bajos, 08500, Vic, Barcelona (SPAIN)

           Test method requested, standard                      USA FCC Part 15.249 10-1-17 Edition: Operation within
                                                                the bands 902 - 928 MHz, 2400 -2483.5 MHz, 5725 -
                                                                5875 MHz, and 24.0 – 24.25 GHz.
                                                                USA FCC Part 15.209 10-1-17 Edition: Radiated
                                                                emission limits; general requirements.
                                                                CANADA RSS-210 Issue 9 (August 2016).
                                                                CANADA RSS-Gen Issue 5 (April 2018).
                                                                ANSI C63.10-2013: American National Standard for
                                                                Testing Unlicensed Wireless Devices.
           Summary                                              IN COMPLIANCE
           Approved by (name / position & signature)            A. Llamas                              Firmado digitalmente
                                                                                                       por ALEJANDRO
                                                                RF Lab. Manager                        LLAMAS RODRIGUEZ
                                                                                                       Fecha: 2018.10.31
                                                                                                       09:37:02 +01'00'


Report No: (NIE) 59091RRF.001                                                                                             2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




            Date of issue                                    2018-10-31


            Report template No                               FDT08_21




 Report No: (NIE) 59091RRF.001                               Page 2 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    Index
    Competences and guarantees .................................................................................................... 4
    General conditions ...................................................................................................................... 4
    Uncertainty ................................................................................................................................. 4
    Usage of samples ....................................................................................................................... 5
    Test sample description .............................................................................................................. 5
    Identification of the client............................................................................................................. 6
    Testing period and place ............................................................................................................. 6
    Document history ........................................................................................................................ 6
    Environmental conditions ............................................................................................................ 6
    Remarks and comments ............................................................................................................. 7
    Testing verdicts........................................................................................................................... 8
    Summary .................................................................................................................................... 8
    Appendix A: Test results ............................................................................................................. 9




 Report No: (NIE) 59091RRF.001                                        Page 3 of 28                                                            2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Competences and guarantees
    DEKRA Testing and Certification is a testing laboratory accredited by the National Accreditation Body (ENAC -
    Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
    DEKRA Testing and Certification is a laboratory with a measurement facility in compliance with the
    requirements of Section 2.948 of the FCC rules and has been added to the list of facilities whose measurements
    data will be accepted in conjuction with applications for Certification under Parts 15 or 18 of the Commission's
    Rules. Registration Number: 720267.
    DEKRA Testing and Certification is a laboratory with a measurement site in compliance with the requirements of
    RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian Certification and
    Engineering Bureau. Reference File Number: ISED 4621A-4.
    In order to assure the traceability to other national and international laboratories, DEKRA Testing and
    Certification has a calibration and maintenance program for its measurement equipment.
    DEKRA Testing and Certification guarantees the reliability of the data presented in this report, which is the
    result of the measurements and the tests performed to the item under test on the date and under the conditions
    stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and
    Certification at the time of performance of the test.
    DEKRA Testing and Certification is liable to the client for the maintenance of the confidentiality of all information
    related to the item under test and the results of the test.
    The results presented in this Test Report apply only to the particular item under test established in this
    document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of DEKRA Testing and Certification.


General conditions
         1. This report is only referred to the item that has undergone the test.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
            or competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written
            permission of DEKRA Testing and Certification.
         4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
            previous written permission of DEKRA Testing and Certification and the Accreditation Bodies.




Uncertainty
    Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification internal document
    PODT000.




 Report No: (NIE) 59091RRF.001                               Page 4 of 28                                     2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Usage of samples
     Samples undergoing test have been selected by: the client.
     Sample S/01 is composed of the following elements:

        Control Nº                          Description                      Model            Serial Nº       Date of reception

        59091/001                            Transmitter                   RB-TX10B              ---              2018-10-11

          1. Sample S/01 has undergone the following test(s):
          All radiated tests indicated in Appendix A.


     Sample S/02 is composed of the following elements:

        Control Nº                          Description                      Model            Serial Nº       Date of reception

        59091/003                 Transmitter with antenna                 RB-TX10B              ---              2018-10-11
                                        connector

          1. Sample S/02 has undergone the following test(s):
          All conducted tests indicated in Appendix A.




Test sample description
  Description of product ................. :               916MHz multifrequency transmitter for safety edge connection
  Rated power supply .................... :              Voltage and Frequency

                                                                AC:

                                                                DC: 3.6 Vdc.

  Software version ......................... :           RBAND3T_ULMEP_02.04.11.00
  Hardware version ........................ :            S-RB3T-MEN-EL
  Mounting position ........................ :                  Table top equipment
                                                                Wall/Ceiling mounted equipment
                                                                Floor standing equipment
                                                                Hand-held equipment
                                                                Other: Door installation
  Accessories (not part of the test                      Description                                   Type       Manufacturer
  item) ............................................ :




 Report No: (NIE) 59091RRF.001                                         Page 5 of 28                                       2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Identification of the client
JCM TECHNOLOGIES, S.A.
C/Morgades, 46 Bajos, 08500, Vic, Barcelona (SPAIN).


Testing period and place
       Test Location               DEKRA Testing and Certification S.A.U.
         Date (start)              2018-10-15
        Date (finish)              2018-10-15


Document history
    Report number                     Date                                               Description
    59091RRF.001                 2018-10-31           First release




Environmental conditions
    In the control chamber, the following limits were not exceeded during the test:

                                                                      Min. = 15 ºC
              Temperature
                                                                      Max. = 35 ºC
                                                                      Min. = 20 %
              Relative humidity
                                                                      Max. = 75 %
              Shielding effectiveness                                 > 100 dB
              Electric insulation                                     > 10 k
              Reference resistance to earth                           <1



    In the semianechoic chamber, the following limits were not exceeded during the test.

                                                                      Min. = 15 ºC
              Temperature
                                                                      Max. = 35 ºC
                                                                      Min. = 20 %
              Relative humidity
                                                                      Max. = 75 %
                                                                      Min. = 860 mbar
              Air pressure
                                                                      Max. = 1060 mbar
              Shielding effectiveness                                 > 100 dB
              Electric insulation                                     > 10 k
              Reference resistance to earth                           <1
                                                                      < ±4 dB at 10 m distance between item under test
              Normal site attenuation (NSA)
                                                                      and receiver antenna, (30 MHz to 1000 MHz)
                                                                      More than 75% of illuminated surface is between 0
              Field homogeneity
                                                                      and 6 dB (26 MHz to 1000 MHz).



 Report No: (NIE) 59091RRF.001                                        Page 6 of 28                                        2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    In the chamber for conducted measurements, the following limits were not exceeded during the test:


                 Temperature                                  Min. = 15 ºC
                                                              Max. = 35 ºC
                 Relative humidity                            Min. = 20 %
                                                              Max. = 35 %
                 Air pressure                                 Min. = 860 mbar
                                                              Max. = 1060 mbar
                 Shielding effectiveness                      > 100 dB
                 Electric insulation                          > 10 k
                 Reference resistance to earth                <1




Remarks and comments
    The tests have been performed by the technical personnel: José Alberto Aranda and Miguel Ángel Torres.
    Used instrumentation:

         Conducted Measurements
                                                                            Last Cal. date   Cal. due date
            1.     Spectrum analyser Agilent E4440A                           2017/10          2019/10


         Radiated Measurements
                                                                            Last Cal. date    Cal. due date
                   Semianechoic Absorber Lined Chamber
           1.                                                                   N.A.              N.A.
                   ETS FACT3 200STP
                   BiconicalLog antenna ETS LINDGREN                          2018/07            2021/07
           2.
                   3142E
                   Multi Device Controller   MESSTECHNIK
           3.                                                                   N.A.              N.A.
                   DAV-RR
                   Double-ridge Guide Horn antenna 1-18 GHz
           4.                                                                 2018/01            2021/01
                   SCHWARZBECK BBHA 9120 D
                   Spectrum analyser Rohde & Schwarz                          2018/02            2020/02
           5.
                   FSV40
           6.      EMI Test Receiver R&S ESR7                                 2017/08            2019/08
                   RF pre-amplifier 30 MHz-6 GHz Bonn
           7.                                                                 2018/07            2019/07
                   Elektronik BLNA 0360-01N
                   RF pre-amplifier 1-18 GHz Bonn Elektronik
           8.                                                                 2018/03            2019/03
                   BLMA 0118-3A




 Report No: (NIE) 59091RRF.001                               Page 7 of 28                                     2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Testing verdicts

                            Not applicable :                                         N/A

                            Pass       :                                             P

                            Fail       :                                             F

                            Not measured :                                           N/M



Summary

                                                   FCC PART 15 / RSS-210 PARAGRAPH
                                           Requirement – Test case                         Verdict   Remark
  FCC 15.249 Subclause (a) / RSS-210 B.10. (a) Field strength of fundamental and
                                                                                             P
                                               harmonics emissions
  FCC 15.249 Subclause (d) / RSS-210 B.10. (b) Emissions radiated outside of the
                                                                                             P
                                               specific frequency bands
  Supplementary information and remarks:
  None.




 Report No: (NIE) 59091RRF.001                                Page 8 of 28                            2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix A: Test results




 Report No: (NIE) 59091RRF.001                               Page 9 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                                 INDEX

    TEST CONDITIONS ...............................................................................................................................................11
    Occupied Bandwidth ...............................................................................................................................................13
    Duty cycle ...............................................................................................................................................................16
    Section 15.249 Subclause (a) / RSS-210 B.10. (a) Field strength of Fundamental. ..............................................18
    Section 15.249 Subclause (a) and (d) / RSS-210 B.10 (b) Emissions limitations radiated (Transmitter). .............21




 Report No: (NIE) 59091RRF.001                                                 Page 10 of 28                                                                     2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


                                                             TEST CONDITIONS


Power supply (V):
Vnominal = 3.6 Vdc
Type of power supply = 2x3,6Vdc ER14505 AA.
Type of antenna = Printed in circuit.
Declared Gain for antenna = 0 dBi


TEST FREQUENCIES:
Lowest channel: 902.30 MHz
Middle channel: 915.65 MHz
Highest channel: 927.70 MHz



CONDUCTED MEASUREMENTS
The equipment under test was set up inside a climatic chamber and it is connected to the spectrum analyzer using
low loss RF cable.




The measurements are corrected taking into account the cable loss.




RADIATED MEASUREMENTS
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a distance
of 3 m for the frequency range 30 MHz-1000 MHz (30 MHz-1000 MHz Bilog antenna) and at a distance of 1m for
the frequency range 1 GHz-10 GHz (1 GHz-18 GHz Double ridge horn antenna).
For radiated emissions in the range 1 GHz-10 GHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for
determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation and
orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna height was
varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.




 Report No: (NIE) 59091RRF.001                                  Page 11 of 28                           2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated measurements setup f < 1 GHz




Radiated measurements setup f > 1 GHz




 Report No: (NIE) 59091RRF.001                               Page 12 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                             Occupied Bandwidth


RESULTS

(see next plots).


                                                               Lowest frequency   Middle frequency   Highest frequency
                                                                 902.30 MHz         915.65 MHz         927.70 MHz
                      99% bandwidth (kHz)                          207.035            204.949            206.034
                    -26 dBc bandwidth (kHz)                        220.956            220.336            220.951
                Measurement uncertainty (kHz)                                         <±0.83




 Report No: (NIE) 59091RRF.001                                    Page 13 of 28                                     2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Lowest Channel




Middle Channel




 Report No: (NIE) 59091RRF.001                               Page 14 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Highest channel




 Report No: (NIE) 59091RRF.001                               Page 15 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                             Duty cycle

Computation of duty-cycle correction factor

Number of pulses within 100 ms: 1




Pulse duration: 2.090 ms.




 Report No: (NIE) 59091RRF.001                               Page 16 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Duty-cycle correction factor calculation.

Sub-pulse                            Duration (ms)            Number of pulses   Sub-pulse    “On
                                                                                 Time” (ms)
1                                    2.090                    1                  2.090
                                                              TOTAL ON TIME      2.090

Duty cycle correction factor δ = 2.090/ 100 = 0.0209
δ = 20 log (0.0209) = -33.60 dB




 Report No: (NIE) 59091RRF.001                               Page 17 of 28                          2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


           Section 15.249 Subclause (a) / RSS-210 B.10. (a) Field strength of Fundamental.


SPECIFICATION

The field strength of emissions from intentional radiators shall comply with the following

       Fundamental                    Field strength of                   Field strength            Measurement
     frequency (MHz)                fundamental (mV/m)                      (dBµV/m)                distance (m)
          902 - 928                               50                           93.98                     3
      2400 – 2483.5                               50                           93.98                     3
        5725 - 5875                               50                           93.98                     3
       24000-24250                               250                          107.96                     3

For frequencies above 1000 MHz, the above field strength limits are based on average limits. However,
the peak field strength of any emission shall not exceed the maximum permitted average limits specified
above by more than 20 dB under any condition of modulation.




RESULTS

The transmission is pulsed so the average values of transmitter fundamental emissions are
calculated from the measured peak values using the duty cycle correction factor δ as indicated in
standard ANSI C63.10-2013.


                                                       Lowest frequency          Middle frequency     Highest frequency
                                                             902.30 MHz             915.65 MHz          927.70 MHz
   Field strength (dBµV/m) peak                               109.09                    110.20               109.64
   Duty cycle correction factor δ                              -33.60                   -33.60               -33.60
Field strength (dBµV/m) average                                75.49                    76.60                76.04
  Measurement uncertainty (dB)                                                          <±3.88



Verdict: PASS




 Report No: (NIE) 59091RRF.001                                          Page 18 of 28                                     2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


FIELD STRENGTH
Lowest Channel




Middle Channel




 Report No: (NIE) 59091RRF.001                               Page 19 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Highest Channel




 Report No: (NIE) 59091RRF.001                               Page 20 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    Section 15.249 Subclause (a) and (d) / RSS-210 B.10 (b) Emissions limitations radiated
                                        (Transmitter).

SPECIFICATION

The field strength of harmonics from intentional radiators shall comply with the following

       Fundamental                     Field strength of     Field strength of   Measurement
     frequency (MHz)                  harmonics (µV/m)          harmonics        distance (m)
                                                                (dBµV/m)
          902 - 928                              500                  54              3
      2400 – 2483.5                              500                  54              3
        5725 - 5875                              500                  54              3
       24000-24250                              2500                67.96             3
Emissions radiated outside of the specific frequency bands, except for harmonics, shall be attenuated by
at least 50 dB below the level of fundamental or to the general radiated emission limits specified in
section 15.209:

    Frequency Range                Field strength (µV/m)       Field strength    Measurement
         (MHz)                                                   (dBµV/m)        distance (m)
        0.009-0.490                       2400/F(kHz)                  -             300
        0.490-1.705                      24000/F(kHz)                  -             30
        1.705 - 30.0                              30                   -             30
            30 - 88                              100                  40              3
           88 - 216                              150                 43.5             3
          216 - 960                              200                  46              3
        960 - 25000                              500                  54              3
Whichever is the lesser attenuation.


RESULTS:
The situation and orientation was varied to find the maximum radiated emission. It was also rotated 360º
and the antenna height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.
All tests were performed in a semi-anechoic chamber at a distance of 3 m for the frequency range 30
MHz-1000 MHz and at distance of 1m for the frequency range 1 GHz-10 GHz.
The field strength is calculated by adding correction factor to the measured level from the spectrum
analyzer. This correction factor includes antenna factor, cable loss and pre-amplifiers gain.

The transmission is pulsed so the average values of spurious emissions are calculated from the
measured peak values using the duty cycle correction factor δ as indicated in standard ANSI C63.10-
2013.

 Report No: (NIE) 59091RRF.001                               Page 21 of 28                      2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Frequency range 30 MHz-1000 MHz.

1. CHANNEL: LOWEST (902.30 MHz).

                  Spurious                    Polarization     Detector      Emission Level   Measurement
              frequency (MHz)                                                  (dBµV/m)        Uncertainty
                                                                                                  (dB)
                     642.314                          V      Quasi-Peak          28.5           <±3.88
                     694.243                          V      Quasi-Peak          28.0           <±3.88
                     746.364                          V      Quasi-Peak          28.2           <±3.88
                     850.316                          V      Quasi-Peak          33.9           <±3.88
                     928.268                          V      Quasi-Peak          38.4           <±3.88
                     954.304                          V      Quasi-Peak          35.4           <±3.88




2. CHANNEL: MIDDLE (915.65 MHz).

                  Spurious                    Polarization     Detector      Emission Level   Measurement
              frequency (MHz)                                                  (dBµV/m)        Uncertainty
                                                                                                  (dB)
                     655.699                          V      Quasi-Peak          28.7           <±3.88
                     707.658                          V      Quasi-Peak          27.9           <±3.88
                     746.620                          V      Quasi-Peak          28.7           <±3.88
                     759.650                          V      Quasi-Peak          28.6           <±3.88
                     837.671                          V      Quasi-Peak          31.5           <±3.88
                     889.695                          V      Quasi-Peak          39.2           <±3.88
                     941.622                          V      Quasi-Peak          39.9           <±3.88




 Report No: (NIE) 59091RRF.001                               Page 22 of 28                                   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


3. CHANNEL: HIGHEST (927.70 MHz).

                  Spurious                    Polarization     Detector      Emission Level   Measurement
              frequency (MHz)                                                  (dBµV/m)        Uncertainty
                                                                                                  (dB)
                     667.695                          V      Quasi-Peak          29.9           <±3.88
                     716.726                          V      Quasi-Peak          26.9           <±3.88
                     758.736                          V      Quasi-Peak          28.1           <±3.88
                     849.663                          V      Quasi-Peak          31.2           <±3.88
                     901.657                          V      Quasi-Peak          41.1           <±3.88
                     932.602                          V      Quasi-Peak          42.6           <±3.88
                     940.716                          V      Quasi-Peak          38.5           <±3.88
                     953.678                          V      Quasi-Peak          37.9           <±3.88



Frequency range 1 GHz-10 GHz

All detected signals are harmonics of the fundamental emission.

1. CHANNEL: LOWEST (902.30 MHz).

                  Spurious                    Polarization     Detector      Emission Level   Measurement
              frequency (GHz)                                                  (dBµV/m)        Uncertainty
                                                                                                  (dB)
                                                                 Peak            54.62          <±4.87
                     1.80475                          V
                                                             Average (*)         21.02          <±4.87
                                                                 Peak            60.05          <±4.87
                     5.41345                          V
                                                             Average (*)         26.45          <±4.87
                                                                 Peak            57.95          <±4.87
                     7.21855                          H
                                                             Average (*)         24.35          <±4.87
                                                                 Peak            54.17          <±4.87
                     8.12095                          H
                                               Average (*)     20.57           <±4.87
(*): The average values are calculated from the measured peak values using the duty cycle correction
factor δ.
All other peaks are more than 20 dB below the limit.




 Report No: (NIE) 59091RRF.001                               Page 23 of 28                                   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




2. CHANNEL: MIDDLE (915.65 MHz).

                  Spurious                    Polarization     Detector      Emission Level   Measurement
              frequency (GHz)                                                  (dBµV/m)        Uncertainty
                                                                                                  (dB)
                                                                 Peak            54.27          <±4.87
                     1.83115                          V
                                                             Average (*)         20.67          <±4.87
                                                                 Peak            60.01          <±4.87
                     5.49355                          H
                                                             Average (*)         26.41          <±4.87
                                                                 Peak            55.51          <±4.87
                     6.40915                          H
                                                             Average (*)         21.91          <±4.87
                                                                 Peak            57.29          <±4.87
                     7.32475                          H
                                               Average (*)      23.69           <±4.87
 (*): The average values are calculated from the measured peak values using the duty cycle correction
factor δ.
All other peaks are more than 20 dB below the limit.


3. CHANNEL: HIGHEST (927.70 MHz).

                  Spurious                    Polarization     Detector      Emission Level   Measurement
              frequency (GHz)                                                  (dBµV/m)        Uncertainty
                                                                                                  (dB)
                                                                 Peak            56.87          <±4.87
                     4.63885                          H
                                                             Average (*)         23.27          <±4.87
                                                                 Peak            60.2           <±4.87
                     5.56585                          H
                                                             Average (*)         26.6           <±4.87
                                                                 Peak            61.82          <±4.87
                     6.49405                          H
                                                             Average (*)         28.22          <±4.87
                                                                 Peak            57.02          <±4.87
                     7.42105                          H
                                               Average (*)      23.42           <±4.87
 (*): The average values are calculated from the measured peak values using the duty cycle correction
factor δ.
All other peaks are more than 20 dB below the limit.




Verdict: PASS




 Report No: (NIE) 59091RRF.001                               Page 24 of 28                                   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


FREQUENCY RANGE 30 MHz-1000 MHz.

CHANNEL: Lowest (902.30 MHz).




Note: The carrier was attenuated using a notch filter. The peak shown in the plot above the limit is the
carrier frequency.


CHANNEL: Middle (915.65 MHz).




Note: The carrier was attenuated using a notch filter. The peak shown in the plot above the limit is the
carrier frequency.

 Report No: (NIE) 59091RRF.001                               Page 25 of 28                         2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



CHANNEL: Highest (927.70 MHz).




Note: The carrier was attenuated using a notch filter. The peak shown in the plot above the limit is the
carrier frequency.




 Report No: (NIE) 59091RRF.001                               Page 26 of 28                         2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



FREQUENCY RANGE 1 GHz to 10 GHz.

CHANNEL: Lowest (902.30 MHz).




CHANNEL: Middle (915.65 MHz).




 Report No: (NIE) 59091RRF.001                               Page 27 of 28   2018-10-31


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



CHANNEL: Highest (927.70 MHz).




 Report No: (NIE) 59091RRF.001                               Page 28 of 28   2018-10-31



Document Created: 2018-10-31 09:37:02
Document Modified: 2018-10-31 09:37:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC