MPE Calculation

FCC ID: U5Z-RB-TX10

RF Exposure Info

Download: PDF
FCCID_3410258

                                             CMC Centro Misure Compatibilità S.r.l.
                                                       Via della Fisica, 20
                                                   36016 Thiene (VI) – ITALY
                                                   Tel./Fax +39 0445 367702
                                                www.cmclab.it - info@cmclab.it

                                                    Independent Testing Laboratory




                               MAXIMUM PERMISSIBLE EXPOSURE

Products:           TRANSMITTER FOR AUTOMATIC DOOR SAFETY EDGES
Model:              RB-TX10
FCC ID:             U5Z-RB-TX10


Nominal frequencies .................................................... : 902,30 MHz
                                                                     915,65 MHz
                                                                     927,70 MHz



Acceptance limits                                 F/1500 mW/cm2 on range 300 – 1500 MHz
                                                  1 mW/cm2 on range 1500 – 10000 MHz



                      Maximum permissible exposure for maximum measured power level
     Frequency                 Maximum                     Maximum                  Power Density at    Power Density
        (MHz)                measured power              measured power             20 cm (mW/cm2)     Limit (mW/cm2)
                               (dBµV/m)                      (dBm)
        902,30                       68,80                      -26,43                  4,53E-07            0,602
        915,65                       68,68                      -26,55                  4,40E-07            0,610
        927,70                       67,83                      -27,40                  3,62E-07            0,618
Remarks: Power Density = (P x G) / (4πR2)



                   Maximum permissible exposure for declared maximum specified power
  Operating frequency                Maximum specified                Power Density at 20 cm       Power Density Limit
     range (MHz)                       power (dBm)                          (mW/cm2)                  (mW/cm2)
          902 – 928                             5,00                            6,29E-04                 0,601
Remarks: Power Density = (P x G) /              (4πR2)


Thiene, May 18th, 2017




Ing. Renzo Beghetto
(Laboratory Manager)


                                                                                                                 Page 1 of 1



Document Created: 2017-05-18 10:24:14