User Manual

FCC ID: U5Z-RADIOBAND-TBX

Users Manual

Download: PDF
FCCID_1189819

RADIOBAND SYSTEM INSTALLATION MANUAL




     RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 1
                              JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


CONTENTS

CONTENTS ...................................................................................................................... 2
1. INTRODUCTION ......................................................................................................... 3
  1.1 System description ............................................................................................... 3
  1.2 Normative requirements ...................................................................................... 3
2. THE SYSTEM .............................................................................................................. 5
  2.1 RADIOBAND/TA, RADIOBAND/TBX................................................................... 5
  2.2 RADIOBAND/RU .................................................................................................. 8
  2.3 RADIOBAND/RC-RCS ........................................................................................ 15
3. AUTO-TEST FUNCTION........................................................................................... 19
  3.1 AUTO-TEST DESCRIPTION............................................................................... 19
  3.2 RADIOBAND/RCS CONNECTIONS................................................................... 20
4. RADIOBAND SYSTEM INSTALLATION RECOMMENDATIONS........................... 21
  4.1 Installation on roller door with control panel and RADIOBAND/RU. ............ 21
  4.2 Installation on two-leafed swing door with control panel and
  RADIOBAND/RC-RCS. .............................................................................................. 21
  4.3 Installation on horizontal sectional door with control panel and
  RADIOBAND/RU. ...................................................................................................... 22
  4.4. Installation on angled sectional door with control panel and
  RADIOBAND/RU. ...................................................................................................... 22
  4.5 Installation on stackable sectional door with control panel and
  RADIOBAND/RU. ...................................................................................................... 23
  4.6 Installation on one-leafed residential folding door with control panel with
  RADIOBAND/RC-RCS card connector. .................................................................... 23
  4.7 Installation on one-leafed folding door for communities with control panel
  and RADIOBAND/RU................................................................................................ 24
  4.8 Installation on one-leafed sliding door with control panel and
  RADIOBAND/RU. ...................................................................................................... 24
  4.9 Installation on sliding door with control panel and RADIOBAND/RC-RCS
  card connector........................................................................................................... 25
  4.10 Installation on guillotine door with control panel and RADIOBAND/RU. ... 25
5. JCM CONTROL PANEL DIAGRAM FOR CONNECTION TO THE RADIOBAND
SYSTEM.......................................................................................................................... 26




                    RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 2
                                                                     JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


1. INTRODUCTION

1.1 System description

The Radioband system is designed for installation with a safety edge in garage door
installations.
This system allows for wireless safety edge – control panel connection.

To install this system, you must follow the advice included in this manual and take
the requirements of the applicable normative into account.


1.2 Normative requirements

The directives applicable to this system are:
   - 98/37/EC Machines Directive
   - 73/23/EEC Low Voltage Directive
   - 2004/108/EC Electromagnetic Compatibility Directive
   - R&TTE 1999/5/EC Radio and telecommunication terminal equipment
       Directive

Below are some of the requirements of the applicable harmonised standards:

In accordance with the European low voltage directive, you are informed of the
following requirements:
· For permanently connected equipment, an easily accessible connection device
must be incorporated into the cabling.
· This equipment must be installed in a vertical position and firmly fixed to the
structure of the building.
· This equipment may only be handled by a specialized installer, by maintenance
staff or by a properly instructed operator.
· The instructions for use of this equipment must always remain in the possession
of the user.
· Terminals with a maximum section of 3.8mm2 must be used to connect the
cables.

- The frequency of the Radioband system does not interfere in any way with the
868 MHz remote control systems. However a signal centred at 868,9MHz may
cause a delay on the reaction of the system.
- Always connect the door structure and metal parts to an earthing connection.
- Do not share the power and signal supply.




            RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 3
                                            JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


The Radioband system is in line with the Machines Directive under EN 954-1,
Category 2.

JCM TECHNOLOGIES, S.A. declares herewith that the product
RADIOBAND/TA, RADIOBAND/TBX, RADIOBAND/RU, RADIOBAND/RC-RCS,
complies with the requirements of the 1999/5/ CEE R&TTE Directive,
89/336/EEC Directive on electromagnetic compatibility and 73/23/EEC on low
voltage and its subsequent amendment 93/68/EEC, insofar as the product is
used correctly.


CE DECLARATION OF CONFORMITY
See website www.motion-line.com


For RADIOBAND/T, RADIOBAND/TBX and RADIOBAND/R
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.

To comply with FCC rules, adjustment or modifications of this receiver and/or
transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Any other
changes made, not expressly approved by JCM Technologies, S A could void
the user’s authority to operate the equipment.




            RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 4
                                           JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


2. THE SYSTEM

2.1 RADIOBAND/TA, RADIOBAND/TBX




                                                                   RADIOBAND/TA
     Safety edge connection                          Programming button




                                                                   RADIOBAND/TBX



                                      RADIOBAND/TA                RADIOBAND/TBX
Operating frequency                                       868.90MHz
Power supply                          3V DC (2 x 1.5V LR03 AAA) 3V DC (2 x 1.5V LR6 AA)
Op. consumption                                              12mA
Radiated power                                             < 25mW
Op. temperature                                          -20ºC - +55ºC
Seal                                                         IP66
Dimensions                            85 x 53 x 36mm              160 x 53 x 20mm
Range (guaranteed)                                           10m
Battery life                                                2 years
Minimum time between two                                     7 min
RADIOBAND/TA or RADIOBAND/TBX
activations (for complying with the
R&TTE Directive)




             RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 5
                                                JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


INSTALLATION AND CONNECTIONS
Fix the back of the box to the door. Install the transmitter following the technical
manual and avoid placing metallic surfaces between the receiver and the
transmitter. Pass the cables through the bottom of the transmitter. Connect a
resistive 8K2 safety band directly to terminal B1 and ensure that the safety edge
keeps totally waterproof. Fix the front of the transmitter to the back with the screws
supplied for the purpose.
N.B.: If a non-resistive element (with a contact normally closed) needs to be
connected, the jumper JP4 must be bridged. This application does not comply with
safety standard EN 12453 for the use of motorised garage doors, since the
connection of the resistive element to the RADIOBAND/TA and RADIOBAND/TBX is
not checked.

OPERATION
The receiver checks that all the programmed bands are working properly. If a band
is activated or if there is an error in its operation, the receiver activates the output
relay.

PROGRAMMING RADIOBAND/TA, RADIOBAND/TBX
If the receiver is in programming (see MANUAL PROGRAMMING on page 10 or
16), press the transmitter button to programme it into the receiver.

TRANSMITTER BATTERY LOW INDICATOR (RADIOBAND/TA,
RADIOBAND/TBX)
If the battery of a transmitter programmed into the receiver becomes low, it will
give out 4 short signals every 20 seconds. If there is more than one transmitter
programmed, the safety band must be activated to check whether the receiver then
makes these 4 short signals. If this is the case, the transmitter connected to the
activated safety band will be the one with the low battery. Change it.

CHANGING THE BATTERY
Remove the box cover. The batteries are positioned on the back of the cover.
Replace the two used batteries with new ones, taking into account the polarity
indicated by the connector. Check that the new batteries support the same
temperature range as those they are replacing.




             RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 6
                                              JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


INSTALLATION ADVICE

Install the equipment so that
the cable outlet is at the bottom
                                                          In installations likely to have range problems
                                                          between the transmitter and the receiver,
                                                          the antenna must stand vertically from
                                                          the hole in the gland




                               Do not fit the equipment
                               at ground level




   Do not place metal surfaces between
   the transmitter and the receiver




                                                  The transmitter and receiver antenna
                                                  must be parallel to each other for
                                                  optimum signal reception




* Once the system has been installed, check it works correctly by enabling the
safety edge on the ends of the door.

               RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 7
                                                  JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


2.2 RADIOBAND/RU




Frequency                    868.90MHz
Memory                       6 RADIOBAND/TA and/or RADIOBAND/TBX (3 on
                             relay 1, 3 on relay 2)
Number of relays             2 relays
Power supply                 12/24V AC/DC
Power supply range           9-35V DC
                             8-28V AC
Relay contacts               1A
Consumption: idle/op.        18mA/80mA
Self-test input              2 0/12/24V AC/DC inputs with selectable polarity
Power                        < 25mW
Op. temperature              -20ºC to +85ºC
Seal                         IP54 (with IP65 cable seals)
Box size                     82 x 190 x 40mm
Range (guaranteed)           10 metres


              RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 8
                                          JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


INSTALLATION AND CONNECTIONS
Fix the back of the box to the wall, using the wall plugs and screws supplied.
Install the receiver, close to the door and avoid metal surfaces between the
receiver and the transmitter. Pass the cables through the bottom of the receiver.
Connect the power cables to the terminals of the printed circuit, following the
indications of the connections diagram. Store RADIOBAND/TA and/or
RADIOBAND/TBX. Fix the front of the receiver to the back with the screws supplied
for the purpose.

            1- Power supply 12/24V AC/DC: (+)
            2- Power supply 12/24V AC/DC (-)
            3,4- R1: Connection to the safety band input of the control panel
            (resistive contact 8.2kΩ) with jumper in position BS1 (see
            CONNECTIONS Figure 1). Or to the control panel safety contact input
            (NC) with jumper in position CS1 (see CONNECTION Figure 2).
            5,6- R2: Connection to a second safety band input of the control panel
            (resistive contact 8.2kΩ) with jumper in position BS2. Or to the control
            panel safety contact input (NC) with jumper in position CS2.
            7- AUTOTEST: Common connection safety self-test (-). See
                CONNECTIONS Figure 3 and table POLARIZED SELF-TEST.
            8- AUTOTEST: Self-test connection for R1. See CONNECTIONS Figure
                3 and table POLARIZED AUTO-TEST.
            9- AUTOTEST: Self-test connection for R2. See CONNECTIONS Figure
                3 and table POLARIZED AUTO-TEST.


POLARIZED AUTO-TEST
Check the auto-test output on the control panel, in standby, to see whether the
voltage is 0V (inverted test input) or 12/24V AC/DC (positive polarity). The auto-
test signal of the panel must remain at its maximum for 2 seconds.

                       Autotest    Autotest    Polarity      Jumper       ATEST1      ATEST2
                       output in   output      type          ATEST POL
                       standby     activated
Connection to a        0V          12/24V      Positive      OFF          Connecte    Connecte
equipment with                                                            d*          d*
autotest
                       12/24V      0V          inverted      ON           Connecte    Connecte
                                                                          d*          d*
Connection to a        ---         ---         ---           OFF          No          No
equipment without                                                         connected   connected
autotest**


* N.B.: Only connect the auto-test output to be used.

** Where the auto-test is not used, the system is not checked at the start of the operation,
which means that security normative EN 12453 regarding the use of motorised garage
doors is, in some cases, not complied with.


                  RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 9
                                                     JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


LIGHT INDICATORS
RADIOBAND/R     In operation                                In programming
U-RC-RCS
Relay 1 LED     Normally off.                               On. Indicates the channel to be
                Indicates the status of the relay output.   programmed.
                If R1 is not connected, on.
Relay 2 LED     Normally off.                               On. Indicates the channel to be
                Indicates the status of the relay output.   programmed.
                If R2 is not connected, on.

OPERATION
The receiver checks that all the programmed bands are working properly. If a band
is activated or if there is an error in its operation, the receiver activates the output
relay.

MANUAL PROGRAMMING
RADIOBAND/RU makes it possible to store 6 RADIOBAND/TAs and/or
RADIOBAND/TBXs (3 on Relay 1 and 3 on Relay 2).
Press the receiver programming PROG button for 1s; a sound signal will be heard.
The receiver will go into programming the first relay. If the programming button is
kept pressed, the receiver will go into programming the second relay, moving
cyclically from one really to another. Once the programming relay has been chosen
for the transmitter you want to start using, send the programming code by pressing
the transmitter. Every time a transmitter is programmed, the receiver will emit a
sound signal for 0.5s. If 10 seconds pass without programming, the receiver will
go out of programming mode, emitting two 1s sound signals. If, when
programming a transmitter, the receiver's memory is full, it will emit 7 sound
signals lasting 0.5s and come out of programming.
Note: For a right operation of the system, the transmitter has to be programmed
in one receiver only.

RADIOBAND/TA, RADIOBAND/TBX replacement: In case you need to replace a
RADIOBAND/TA or a RADIOBAND/TBX, it is necessary to reset the system (see
TOTAL RESET on next page) and reprogram all RADIOBAND/TA and/or
RADIOBAND/TBX used in the installation.

SYSTEM CHECK
This function has to be used to check the operation and range of all the devices
once the installation has been carried out.

Press the receiver’s CHECK button for at least 1 second to enter check mode. The
indicator light will come on and four beeps will be heard.
Perform a complete door opening and closing manoeuvre. During the system
check a beep will be heard every 1,5 seconds.

CORRECT OPERATION OF THE SYSTEM
If no other acoustic signal is heard on completing the manoeuvre, the system is
operating correctly. Either press the CHECK button again or wait 5 minutes and the

              RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 10
                                                     JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


RADIOBAND/RU will exit checking automatically, indicating with two beeps that
the check has been correct. The check indicator light will go out.

DETECTION OF BAND FAILURE
If the communication with a RADIOBAND/TA or a RADIOBAND/TBX fails during
checking, or the communication is deficient (for instance, too many communication
retries or poor coverage), the RADIOBAND/RU emits three consecutive beeps,
indicating that an error has occurred. Halt the door manoeuvre and press the safety
bands installed to detect what has failed.
    - If a single beep is heard on pressing a band, this means that the band is
        correct.
    - If three consecutive beeps are heard on pressing the band, this means that
        the band has failed.
        In this event, it is recommended changing the orientation of the
        transmitting-receiving aerials or installing an AED-868 or FLAT-868 outdoor
        aerial to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator
light will flash continuously.
Perform another system check until the result is correct.

Signal coverage
After pressing one of the installed bands, continuous flashes, ranging from 1 to 5,
indicate the signal coverage for this band at the time it was pressed.
 Number of check LED          Coverage          Result of check
         flashes
            1                Very weak           Band failure
            2                   Weak                  OK
            3                  Normal                 OK
            4                   Good                  OK
            5                Very good                OK

TOTAL RESET
In programming mode, keep the programming PROG button pressed down and
make a bridge with the "MR" reset jumper for 3s. The receiver will emit 10 warning
sound signals and then more at a faster frequency, indicating that the operation
has been carried out. The receiver will stay in programming mode.
If 10 seconds elapse without programming, or if you press the programming button
quickly, the receiver will go out of programming mode, emitting two 1s sound
signals.

TRANSMITTER BATTERY LOW INDICATOR (RADIOBAND/TA,
RADIOBAND/TBX)
If the battery of a transmitter programmed into the receiver becomes low, it will
give out 4 short signals every 20 seconds. If there is more than one transmitter
programmed, the safety band must be activated to check whether the receiver then
makes these 4 short signals. If this is the case, the transmitter connected to the
activated safety band will be the one with the low battery. Change it.


           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 11
                                            JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


INSTALLATION ADVICE




                               The transmitter and receiver antenna
                               must be parallel to each other for
                               optimum signal reception




                                                     Do not fit the equipment
                                                     at ground level




  Do not place metal surfaces between
  the transmitter and the receiver




                                          The transmitter and receiver antenna
                                          must be parallel to each other for
                                          optimum signal reception




           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 12
                                            JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


a) Connection to safety edge inlet




b) Connection to security contact inlet




           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 13
                                          JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


c) Auto-test connection with negative polarisation




d) Auto-test connection with positive polarisation




* Once the system has been installed, check it works correctly by enabling the
safety edge on the ends of the door.


           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 14
                                            JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


2.3 RADIOBAND/RC-RCS




Frequency                    868.90MHz
Memory                       6 RADIOBAND/TA and/or
                             RADIOBAND/TBX
Power supply                 pluggable
Power supply range           ---
Consumption: idle/op.        18mA
Self-test input              incorporated
Power                        < 25mW
Op. temperature              -20ºC to +85ºC
Seal                         IP20
Box size                     50x20x17mm
Range (guaranteed)           10 metres




            RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 15
                                      JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


INSTALLATION AND CONNECTIONS
Connection to a control panel using a connector for safety devices.

LIGHT INDICATORS
RADIOBAND/R     In operation                                In programming
U-RC-RCS
Relay 1 LED     Normally off.                               On. Indicates the channel to be
                Indicates the status of the relay output.   programmed.
                If R1 is not connected, on.
Relay 2 LED     Normally off.                               On. Indicates the channel to be
                Indicates the status of the relay output.   programmed.
                If R2 is not connected, on.

OPERATION
The receiver checks that all the programmed bands are working properly. If a band
is activated or if there is an error in its operation, the receiver activates the output
relay.

MANUAL PROGRAMMING
RADIOBAND/RC-RCS makes it possible to store 6 RADIOBAND/TAs and/or
RADIOBAND/TBXs (3 on Relay 1 and 3 on Relay 2).
Press the receiver programming PROG button for 1s; a sound signal will be heard.
The receiver will enter safety band closing programming mode (BSC). If the
programming button is kept pressed, the receiver will enter safety band opening
programming mode (BSO), moving cyclically from one really to another. Once the
programming relay has been chosen for the transmitter you want to start using,
send the programming code by pressing the transmitter. Every time a transmitter is
programmed, the receiver will emit a sound signal for 0.5s. If 10 seconds pass
without programming, the receiver will go out of programming mode, emitting two
1s sound signals. If, when programming a transmitter, the receiver's memory is full,
it will emit 7 sound signals lasting 0.5s and come out of programming.
Note: For a right operation of the system, the transmitter has to be programmed
in one receiver only.

RADIOBAND/TA, RADIOBAND/TBX replacement: In case you need to replace a
RADIOBAND/TA or a RADIOBAND/TBX, it is necessary to reset the system (see
TOTAL RESET on next page) and reprogram all RADIOBAND/TA    and/or
RADIOBAND/TBX used in the installation.

SYSTEM CHECK
This function has to be used to check the operation and range of all the devices
once the installation has been carried out.

Press the receiver’s CHECK button for at least one second to enter check mode.
The indicator light will come on and four beeps will be heard.
Perform a complete door opening and closing manoeuvre. During the system
check a beep will be heard every 1,5 seconds.

CORRECT OPERATION OF THE SYSTEM

              RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 16
                                                     JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


If no other acoustic signal is heard on completing the manoeuvre, the system is
operating correctly. Either press the CHECK button again or wait 5 minutes and the
RADIOBAND/RC-RCS will exit checking automatically, indicating with two beeps
that the check has been correct. The check indicator light will go out.


DETECTION OF BAND FAILURE
If the communication with a RADIOBAND/TA or a RADIOBAND/TBX fails during
checking, or the communication is deficient (for instance, too many communication
retries or poor coverage), the RADIOBAND/RC-RCS emits three consecutive beeps,
indicating that an error has occurred. Halt the door manoeuvre and press the safety
bands installed to detect what has failed.
    - If a single beep is heard on pressing a band, this means that the band is
        correct.
    - If three consecutive beeps are heard on pressing the band, this means that
        the band has failed.
        In this event, it is recommended changing the orientation of the
        transmitting-receiving aerials or installing an AED-868 or FLAT-868 outdoor
        aerial to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator
light will flash continuously.
Perform another system check until the result is correct.

Signal coverage
After pressing one of the installed bands, continuous flashes, ranging from 1 to 5,
indicate the signal coverage for this band at the time it was pressed.
 Number of check LED          Coverage          Result of check
         flashes
            1                Very weak           Band failure
            2                   Weak                  OK
            3                  Normal                 OK
            4                   Good                  OK
            5                Very good                OK

TOTAL RESET
In programming mode, keep the programming PROG button pressed down and
make a bridge with the "MR" reset jumper for 3s. The receiver will emit 10 warning
sound signals and then more at a faster frequency, indicating that the operation
has been carried out. The receiver will stay in programming mode.
If 10 seconds elapse without programming, or if you press the programming button
quickly, the receiver will go out of programming mode, emitting two 1s sound
signals.




           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 17
                                            JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


INSTALLATION ADVICE


                                                 An AED-868 or FLAT 868 antenna extension
                                                 to 868 MHz should be installed for greater
                                                 range.
                                                 Install the external antenna and its cable at a
                                                 place where they are protected against damage
                                                 and An   AED-868and
                                                       vibration,  or FLAT
                                                                       where868noantenna    extension
                                                                                     obstacles    are
                                                      to 868 MHz should be installed for greater range
                                                 expected between all RADIOBAND antennas.




                                                                 Where an antenna extension
                                                                 is not installed, place the receiver
                                                                 card antenna in vertical position




                  868MHz AED-868 or FLAT 868
                  antenna extension with
                  RG 58 coaxial cable




* Once the system has been installed, check it works correctly by enabling the
safety edge on the ends of the door.




           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 18
                                           JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


3. AUTO-TEST FUNCTION
3.1 AUTO-TEST DESCRIPTION

Before starting operations, the control panel must check that the entire security
system is working correctly. The control panel shall not start Auto-test during a
pressed safety edge output.
To make this check, the panel must act on the auto-test signal.

   •   AUTO-TEST timing correct


                                        Tautotest          Tend

        Autotest

                                                                                        RADIOBAND/TA status
                                                                                        Auto-test carried out

        CS = indicates
        the correct
        autotest of all
        bands
                                        Autotest OK
                                                                   The operation can now be
                                                                   carried out



   •   AUTO-TEST timing error

                                  TMAXautotest            Tend

        Autotest

                                                                                      RADIOBAND/TA status
                                                                                      Auto-test carried out



        CS = indicates
        the correct
        autotest of all
                                  Autotest Error
        bands                                                     THE OPERATION CANNOT BE STARED AS
                                                                  THE AUTO-TEST HAS NOT BEEN
                                                                  SUCCESSFULLY COMPLETED


While the auto-test is being run to learn of the status of the RADIOBAND/TA or
RADIOBAND/TBX, the RADIOBAND/RU questions the status of the different Safety
edges inputs. This process ensures the correct working order of the following
parts:
   • Safety edge input
   • RADIOBAND/TA or RADIOBAND/TBX (1 or several).
   • RF Channel (if there is any interference)

           RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 19
                                                    JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


   • RADIOBAND/RU (control and RF)
Switching off the output relay means that the control status and the correct
working order of the RADIOBAND/RU output relay has been checked.


Description                       Tmin              Ttype         Tmax
Tauto-test                        10ms                            3s
Tend                                                50 ms




3.2 RADIOBAND/RCS CONNECTIONS




   1-   Not connected
   2-   RB_S1: Outlet 1 Radioband activation
   3-   Mass
   4-   RB_S2 Outlet 2 Radioband activation
   5-   5Vdc power supply
   6-   RB_AT-1: Inlet 1 Radioband auto-test
   7-   Not connected
   8-   RB_AT-2: Inlet 2 Radioband auto-test




              RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 20
                                            JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


4. RADIOBAND SYSTEM INSTALLATION
RECOMMENDATIONS

4.1 Installation on roller door with control panel and RADIOBAND/RU.




4.2 Installation on two-leafed swing door with control panel and
RADIOBAND/RC-RCS.




         RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 21
                                    JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


4.3 Installation on horizontal sectional door with control panel and
RADIOBAND/RU.




4.4. Installation on angled sectional door with control panel and
RADIOBAND/RU.




         RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 22
                                    JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


4.5 Installation on stackable sectional door with control panel and
RADIOBAND/RU.




4.6 Installation on one-leafed residential folding door with control
panel with RADIOBAND/RC-RCS card connector.




                                         M




         RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 23
                                    JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


4.7 Installation on one-leafed folding door for communities with
control panel and RADIOBAND/RU.




4.8 Installation on one-leafed sliding door with control panel and
RADIOBAND/RU.




                                            M




         RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 24
                                   JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


4.9 Installation on sliding door       with     control     panel     and
RADIOBAND/RC-RCS card connector.




                                           M




4.10 Installation on guillotine door with control panel and
RADIOBAND/RU.




        RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 25
                                  JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


5. JCM CONTROL PANEL DIAGRAM FOR CONNECTION TO
THE RADIOBAND SYSTEM

                       SINGLE-PHASE PANELS
        JCM Control    Applications      Description             Compatibility with
        panels                                                   Radioband system
        START-EU       Roller for        Semi-automatic          RADIOBAND/RU with
                       residential and   operations. 433 or      external power supply
                       commercial        868 MHz radio card
                       use               connection. Start
                                         button and safety
                                         edge connection.
        RESIDENT+DCS      Roller for     Semi-automatic and      RADIOBAND/RU
                       residential use   automatic operations.
                                         Built-in 433 MHz
                                         receiver. Start/stop
                                         button connection,
                                         limit switches and
                                         security contact on
                                         close. Possible to
                                         connect the TBAND
                                         card. 24Vac outlet
                                         Garage light contact
           ROLLER-        Roller for     “Dead-man”              RADIOBAND/RU with
           MOTION      residential and   operations (using GO-   external power supply
                         commercial      BUTTON or GO-
                             use         SWITCH), semi-
                                         automatic. Built-in
                                         868 MHz receiver.
                                         Start button
                                         and safety edge
                                         connection.
           BASIC-EU      Sliding for     Semi-automatic and      RADIOBAND/RU
                       residential and   automatic operations.
                       community use     433 or 868 MHz
                                         radio card connector.
                                         Start, pedestrian and
                                         stop button
                                         connection. Limit
                                         switch, safety edge
                                         and security contact
                                         connection. Garage
                                         light contact 12Vdc
                                         outlet
          MAIN-1T-EU    Swing, folding   Semi-automatic and      RADIOBAND/RU
                       and sliding for   automatic operations.
                       residential and   433 or 868 MHz
                       community use     radio card connector.
                                         Start and stop button
                                         connection. Limit
                                         switch,
                                         safety edge and
                                         security contact
                                         connection. Traffic
                                         light or signal card
                                         connector.
                                         Garage light contact
                                         24Vac outlet Electro-
                                         lock connection.
          MAIN-2T-EU     Same as         Same as MAIN-1T-EU RADIOBAND/RU
                        MAIN-1T-EU       for 2 motors


      RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 26
                                           JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


     ADVANCE      Swing, folding  Semi-automatic and       RADIOBAND/RC or
                  and sliding for automatic operations.    RADIOBAND/RU with
                  residential and Digital programming.     negative polarisation auto-
                   intensive use. Gentle stop.             test function
                                  RADIOBAND and
                                  other force limiting
                                  device (FORCELIMIT
                                  and T-HALL)
                                  connector. 433 or
                                  868 MHz card
                                  connector. Start and
                                  stop button
                                  connection. Limit
                                  switch,
                                  Limit switch, safety
                                  edge and security
                                  contact connection.
                                  Electro-lock
                                  connection. Traffic
                                  light card or signal
                                  card connector.
                                  Garage light contact
                                  24Vac outlet Auto-
                                  test outlet.
   STANDARD-1T-   Swing, folding Semi-automatic and        RADIOBAND/RU
        EU        and sliding for automatic operations.
                  residential and Gentle stop. 433 or
                  community use 868 MHz radio card
                                  connector. Start,
                                  pedestrian, stop, open
                                  and close button
                                  connection. Limit
                                  switch, safety edge
                                  and security contact
                                  connection. Traffic
                                  light connector.
                                  Garage light and
                                  signal contact 24Vac
                                  outlet Electro-lock
                                  connection.
   STANDARD-2T-      Same as      Same as STANDARD-        RADIOBAND/RU
        EU         STANDARD- 1T-EU for 2 motors
                      1T-EU




RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 27
                                    JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


D.C. PANELS




                                        D.C. PANELS
                JCM Control      Applications        Description                    Compatibility with
                panels                                                              Radioband system
                CONTINUE-EU      Sectional, swing,   Semi-automatic and             RADIOBAND/RU
                                 folding and         automatic operations by
                                 sliding for         limit switch or with Hall
                                 residential and     sensor. Time control.
                                 community use       Electronic motor power
                                                     limitation without the need
                                                     for additional devices. 433
                                                     or 868 MHz radio card
                                                     connector. Start and stop
                                                     button connection. Limit
                                                     switch, safety edge and
                                                     security contact connection.
                                                     Garage light
                                                     contact. 24Vac outlet

NUA


                                 THREE-PHASE PANELS
                  JCM Control       Applications       Description                  Compatibility with
                  panels                                                            Radioband system
                  UNIVERSAL-EU      Sectional, swing Semi-automatic and             RADIOBAND/RU
                                    and guillotine for automatic operations. 433    with positive
                                    community use or 868 MHz radio card             polarisation auto-
                                                       connector. Open, start and   test function
                                                       stop button connection.
                                                       Limit switch and security
                                                       contact connection. Signal
                                                       or traffic light card
                                                       connector. Garage light
                                                       contact 24Vac outlet
                                                       Electro-lock connection.
                                                       Auto-test outlet.
                     TRIBASIC-        Winding and      “Dead-man” operations       RADIOBAND/RU
                      MOTION             sectional     Built-in 868 MHz receiver.
                                    for industrial use Open, close, start and stop
                                                       button connection. Limit
                                                       switch and security
                                                       contact connection. Signal
                                                       or traffic light card
                                                       connector.
                                                       Garage light contact 24Vac
                                                       outlet
                     TRIBASIC       Sectional, swing Semi-automatic and            RADIOBAND/RU
                                     and sliding for automatic operations. 433
                                     community use or 868 MHz radio card
                                                       connector. Start and stop
                                                       button connection. Limit
                                                       switch,
                                                       safety edge and security
                                                       contact connection. Signal
                                                       or traffic light card
                                                       connector. Garage
                                                       light contact. 24Vac outlet
                                                       Auto-test outlet.



              RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 28
                                                     JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED


     TRIBASIC-S/I       Same as        Same as TRIBASIC               RADIOBAND/RU
                       TRIBASIC        without ON/OFF switch.
                                       Auto-test outlet.
     TRIBASIC-IND        Same as       Same as TRIBASIC but in        RADIOBAND/RU
                        TRIBASIC       INDUSTRIAL box. Auto-
                                       test outlet.
     INDUSTRIAL-         Swing for     “Dead-man” operations          RADIOBAND/RU
        MAN           industrial use   433 or 868 MHz radio
                                       card connector. Open, start
                                       and stop button
                                       connection. Limit switch
                                       connection. Signal
                                       or traffic light card
                                       connector. Garage light
                                       contact 24Vac outlet
                                       Electro-lock connection.
                                       INDUSTRIAL box with
                                       general circuit breaker
                                       switch.
    INDUSTRIAL-EU          Swing,      Semi-automatic and             RADIOBAND/RU
                         sectional,    automatic operations. 433      with positive
                        sliding and    or 868 MHz radio card          polarisation auto-
                         guillotine    connector. Open, start and     test function
                    for industrial use stop button connection.
                                       Limit switch and security
                                       contact connection. Signal
                                       or traffic light card
                                       connector. Garage light
                                       contact 24Vac outlet
                                       Electro-lock connection.
                                       INDUSTRIAL box with
                                       general circuit breaker
                                       switch. Auto-test outlet.
     TRI-ADVANCE        Fast doors     Semi-automatic and             RADIOBAND/RCS
                                       automatic operations. 433      or RADIOBAND/RU
                                       or 868 MHz radio card          with negative
                                       connector. Open, start and     polarisation auto-
                                       stop button connection.        test function
                                       Limit switch, security
                                       contact and safety edge
                                       connection. Hall sensor
                                       connection. Signal or
                                       traffic light card / garage
                                       light connector. Connector
                                       for magnetic sensor card.
                                       24Vac outlet Electro-break
                                       outlet. INDUSTRIAL box
                                       with general circuit breaker
                                       switch. Auto-test outlet.




RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 29
                                    JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED



Document Created: 2009-07-29 14:21:16
Document Modified: 2009-07-29 14:21:16

© 2024 FCC.report