Test Report

FCC ID: U5Z-MUV

Test Report

Download: PDF
FCCID_3280266

AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456


            FCC LISTED, REGISTRATION                                                                                         Informe de ensayo nº:
            NUMBER: 720267
                                                                                                                                Test report No:
            IC LISTED REGISTRATION NUMBER
            IC 4621A-2                                                                                                       NIE: 51368RRF.001

                                                                                         Test report
                                                                    USA FCC Part 15.231, 15.209
                                                                    CANADA RSS-210, RSS-Gen
                Radio Frequency Devices. Periodic operation in the band 40.66-40.70 MHz and above 70
                                                        MHz.
                   Licence-Exempt Radio Apparatus (All Frequency Bands): Category I Equipment.
                    General Requirements and Information for the Certification of Radio Apparatus.
            Identificación del objeto ensayado......................:                     Transmitter
            Identification of item tested

            Marca ...................................................................:    JCM TECHNOLOGIES, S.A.
            Trademark

            Modelo y/o referencia tipo ..................................:                MUV2 FCC / MUV4 FCC / MUVEVO4HID-CIS
            Model and /or type reference

            Other identification of the product ....................:                     FCC ID: U5Z-MUV
                                                                                          IC: 8572A-MUV
            Final HW version ................................................:            2000538 (S-MUV2 FCC-EL) / 2000539 (S-MUV4 FCC-EL)
            Final SW version .................................................:           GONOAPS_RFPIC_03090000
            Características .....................................................:        Not provided data
            Features

            Fabricante ............................................................:      JCM TECHNOLOGIES,S.A.
            Manufacturer
                                                                                          C/ Morgades,46 Bajos, 08500, Vic, Barcelona. SPAIN
            Método de ensayo solicitado, norma...................:                        USA FCC Part 15.231 10-1-15 Edition: Periodic operation in
            Test method requested, standard                                               the band 40.66-40.70 MHz and above 70 MHz.
                                                                                          USA FCC Part 15.209 10-1-15 Edition: Radiated emission
                                                                                          limits; general requirements.
                                                                                          CANADA RSS-210 Issue 9 (August 2016).
                                                                                          CANADA RSS-Gen Issue 4 (November 2014).
                                                                                          ANSI C63.10-2013: American National Standard for Testing
                                                                                          Unlicensed Wireless Devices.
            Resultado ..............................................................:     IN COMPLIANCE
            Summary

            Aprobado por (nombre / cargo y firma) ...........:                            A. Llamas / RF Lab. Manager
                                                                                                                                        Firmado
            Approved by (name / position & signature)                                                                                   digitalmente por
                                                                                                                                        ALEJANDRO LLAMAS
                                                                                                                                        RODRIGUEZ
            Fecha de realización ...........................................:             2016-12-19                                    Fecha: 2016.12.19
            Date of issue                                                                                                               12:45:21 +01'00'


            Formato de informe No. ......................................:                FDT08_17
            Report template No




Report No: (NIE)
51368RRF.001                                                                                                                                       2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




        Index
    Competences and guarantees .........................................................................................................................3
    General conditions .........................................................................................................................................3
    Uncertainty ....................................................................................................................................................3
    Usage of samples ...........................................................................................................................................3
    Test sample description .................................................................................................................................4
    Identification of the client .............................................................................................................................4
    Testing period ................................................................................................................................................4
    Environmental conditions..............................................................................................................................5
    Remarks and comments .................................................................................................................................6
    Testing verdicts .............................................................................................................................................8
    Appendix A – Test result...............................................................................................................................9




Report No: (NIE)
51368RRF.001                                                                   Page 2 of 22                                                                     2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




    Competences and guarantees
    AT4 wireless is a laboratory with a measurement facility in compliance with the requirements of Section 2.948 of the
    FCC rules and has been added to the list of facilities whose measurements data will be accepted in conjuction with
    applications for Certification under Parts 15 or 18 of the Commission's Rules. Registration Number: 720267.
    AT4 wireless is a laboratory with a measurement site in compliance with the requirements of RSS 212, Issue 1
    (Provisional) and has been added to the list of filed sites of the Canadian Certification and Engineering Bureau.
    Reference File Number: IC 4621A-2.
    In order to assure the traceability to other national and international laboratories, AT4 wireless has a calibration and
    maintenance program for its measurement equipment.
    AT4 wireless guarantees the reliability of the data presented in this report, which is the result of the measurements and
    the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on
    the knowledge and technical facilities available at AT4 wireless at the time of performance of the test.
    AT4 wireless is liable to the client for the maintenance of the confidentiality of all information related to the item
    under test and the results of the test.
    The results presented in this Test Report apply only to the particular item under test established in this document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of AT4 wireless.

    General conditions
         1. This report is only referred to the item that has undergone the test.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
            competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written permission of
            AT4 wireless.
         4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written
            permission of AT4 wireless and the Accreditation Bodies.

    Uncertainty
    Uncertainty (factor k=2) was calculated according to the AT4 wireless internal document PODT000.

    Usage of samples
    Samples undergoing test have been selected by: the client
    Sample M/01 is composed of the following elements:

        Control Nº                       Description                Model                Serial Nº          Date of reception

        51368/029                        Transmitter             MUV2 FCC            1016003 851612            2016-10-27

         1. Sample M/01 has undergone following test(s) in appendix A:
             Section 15.231 Subclause (c) / RSS-210 A.1.3: 20 dB Emission Bandwidth and Occupied Bandwidth.




Report No: (NIE)
51368RRF.001                                                 Page 3 of 22                                                  2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




    Sample M/02 is composed of the following elements:

        Control Nº                       Description               Model               Serial Nº        Date of reception

        51368/028                        Transmitter            MUV2 FCC            1016003 851614         2016-10-27

         1. Sample M/02 has undergone following test(s) in appendix A:
             Section 15.231 Subclause (b) & 15.209 / RSS-210 A.1.2. & RSS-Gen: Field strength and Emission limitations
             radiated (Transmitter).


    Sample M/03 is composed of the following elements:

        Control Nº                       Description               Model               Serial Nº        Date of reception

        51368/030                        Transmitter            MUV2 FCC            1016003 851613         2016-10-27

         1. Sample M/03 has undergone following test(s) in appendix A:
             Section 15.231 Subclause (a) (1) / RSS-210 A.1.1.: Transmitter deactivation.



    Test sample description
    The test sample consists of an 868MHz radio transmitter with high security rolling code and side-prog system.

    Identification of the client
    JCM TECHNOLOGIES,S.A.
    C/ Morgades, 46 Bajos, 08500, Vic, Barcelona SPAIN

    Testing period
    The performed test started on 2015-11-24 and finished on 2015-11-25.
    The tests have been performed at AT4 wireless.




Report No: (NIE)
51368RRF.001                                                Page 4 of 22                                            2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




    Environmental conditions
    In the control chamber, the following limits were not exceeded during the test:


                                                          Min. = 15 ºC
              Temperature
                                                          Max. = 35 ºC
                                                          Min. = 20 %
              Relative humidity
                                                          Max. = 75 %
              Shielding effectiveness                     > 100 dB
              Electric insulation                         > 10 kΩ
              Reference resistance to earth               <1Ω


    In the semianechoic chamber, the following limits were not exceeded during the test.

                                                          Min. = 15 ºC
              Temperature
                                                          Max. = 35 ºC
                                                          Min. = 20 %
              Relative humidity
                                                          Max. = 75 %
                                                          Min. = 860 mbar
              Air pressure
                                                          Max. = 1060 mbar
              Shielding effectiveness                     > 100 dB
              Electric insulation                         > 10 kΩ
              Reference resistance to earth               <1Ω
                                                          < ±4 dB at 10 m distance between item under test and
              Normal site attenuation (NSA)
                                                          receiver antenna, (30 MHz to 1000 MHz)
                                                          More than 75% of illuminated surface is between 0 and 6
              Field homogeneity
                                                          dB (26 MHz to 1000 MHz).


    In the chamber for conducted measurements, the following limits were not exceeded during the test:

              Temperature                                   Min. = 15 ºC
                                                            Max. = 35 ºC
              Relative humidity                             Min. = 20 %
                                                            Max. = 35 %
              Air pressure                                  Min. = 860 mbar
                                                            Max. = 1060 mbar
              Shielding effectiveness                       > 100 dB
              Electric insulation                           > 10 kΩ
              Reference resistance to earth                 <1Ω




Report No: (NIE)
51368RRF.001                                               Page 5 of 22                                             2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




    Remarks and comments
    1: Used instrumentation:
        Conducted Measurements
                                                                      Last Cal. date   Cal. due date
          1.      Spectrum analyser Agilent E4440A                      2015/10          2017/10
          2.      DC power supply R&S NGPE 40/40                        2014/11          2017/11


         Radiated Measurements

                                                                      Last Cal. date   Cal. due date
                  Semianechoic Absorber Lined Chamber ETS FACT3
          1.                                                              N.A.             N.A.
                  200STP
          2.      BiconicalLog antenna ETS LINDGREN 3142E               2014/03          2017/03
          3.      Multi Device Controller EMCO 2090                      N.A.             N.A.
                  Double-ridge Guide Horn antenna 1-18 GHz
          4.                                                            2013/11          2016/11
                  SCHWARZBECK BBHA 9120 D
                  Broadband      Horn      antenna   18-40    GHz
          5.                                                            2014/03          2017/03
                  SCHWARZBECK BBHA 9170
          6.      EMI Test Receiver R&S ESU 40                          2016/03          2018/03
          7.      Spectrum analyser Rohde & Schwarz FSW50               2015/12          2017/12
                  RF pre-amplifier 10 MHz-6 GHz SCHWARZBECK
          8.                                                            2016/04          2017/04
                  BBV9743
                  RF pre-amplifier 1-18 GHz Bonn Elektronik BLMA
          9.                                                            2016/02          2018/02
                  0118-1M


    2: Testing has been carried out on model MUV2 FCC which, according to manufacturer’s declaration, presents no RF and
    EMC functional differences with respect to models MUV4 FCC and MUVEVO4HID-CIS. See declaration below.




Report No: (NIE)
51368RRF.001                                           Page 6 of 22                                           2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




Report No: (NIE)
51368RRF.001                                          Page 7 of 22   2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




    Testing verdicts
                           Not applicable ......................................................................... :           N/A

                           Pass .......................................................................................... :     P

                           Fail ........................................................................................... :    F

                           Not measured .......................................................................... :            N/M




                                         FCC PART 15 PARAGRAPH / RSS-210                                                                   VERDICT
                                                                                                                                      NA    P   F NM
  Section 15.231 Subclause (a) (1) / RSS-210 A.1.1.                                         Transmitter deactivation                        P
  Section 15.231 Subclause (c) / RSS-210 A.1.3. ..                                          Bandwidth                                       P
  Section 15.231 Subclause (b) / 15.209 / RSS-210 A.1.2.
  / RSS-Gen                                                                                Field strength and Emission limitations          P
                                                                                           radiated (Transmitter)




Report No: (NIE)
51368RRF.001                                                                       Page 8 of 22                                                 2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




    Appendix A – Test result




Report No: (NIE)
51368RRF.001                                          Page 9 of 22   2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456


                                                                                   INDEX


      TEST CONDITIONS ......................................................................................................................................................... 11

      Section 15.231 Subclause (a) (1) / RSS-210 A.1.1. Transmitter deactivation. .................................................................... 13

      Section 15.231 Subclause (c) / RSS-210 A.1.3. Bandwidth ................................................................................................ 14

      Occupied Bandwidth ........................................................................................................................................................... 15

      Section 15.231 Subclause (b) /15.209 / RSS-210 A.1.2. / RSS-Gen. Field strength and Emission limitations radiated
      (Transmitter) ........................................................................................................................................................................ 16




Report No: (NIE)
51368RRF.001                                                                         Page 10 of 22                                                                             2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456


                                                      TEST CONDITIONS


Power supply (V):
      Vnominal = 3.0 Vdc
Type of power supply = CR2032 battery.
Type of antenna = Integral antenna




TEST FREQUENCIES:
The equipment transmits at the nominal frequency of 868.32 MHz.


CONDUCTED MEASUREMENTS
The equipment under test was set up in a shielded room and it is directly connected to the spectrum analyzer.




RADIATED MEASUREMENTS
The equipment under test was scanned for spurious emissions in the frequency range 30 to 10000 MHz.
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a
distance of 3 m for the frequency range 30 MHz-1000 MHz (30 MHz-1000 MHz Bilog antenna) and at a
distance of 1m for the frequency range 1 GHz-10 GHz (1 GHz-18 GHz Double ridge horn antenna).
For radiated emissions in the range 1 GHz-10 GHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for
determining compliance. The sample is prepared so that transmits continuously when the batteries are
connected
The equipment under test was set up on a non-conductive platform above the ground plane and the situation
and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna
height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.




Report No: (NIE)
51368RRF.001                                             Page 11 of 22                                    2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456



Radiated measurements setup f < 1 GHz




Radiated measurements setup f > 1 GHz




Report No: (NIE)
51368RRF.001                                          Page 12 of 22   2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




                         Section 15.231 Subclause (a) (1) / RSS-210 A.1.1. Transmitter deactivation.


SPECIFICATION
A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within
not more than 5 seconds of being released.


RESULTS
The equipment can only operate in manual mode.
The transmission is activated by pressing a button and ceases after releasing it in less than 5 seconds (see next
plot).




Verdict: Pass




Report No: (NIE)
51368RRF.001                                             Page 13 of 22                                      2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




                                      Section 15.231 Subclause (c) / RSS-210 A.1.3. Bandwidth


SPECIFICATION
FCC 15.231: The bandwidth of the emission shall be no wider than 0.25 % of the centre frequency for devices
operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB down from the
modulated carrier.

RESULTS (see next plots)
Nominal centre frequency = 868.32 MHz
Limit of spectrum bandwidth = 0.25 % of 868.32 MHz = 2170.80 kHz




             Measured 20 dB Bandwidth (kHz)                                      32.60
               Measurement uncertainty (kHz)                                    <±0.85




Verdict: PASS




Report No: (NIE)
51368RRF.001                                                Page 14 of 22                             2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




                                                      Occupied Bandwidth
SPECIFICATION
RSS-210. A.1.3.: the 99% bandwidth shall be no wider than 0.25% of the centre frequency for devices
operating between 70 MHz and 900 MHz.

RESULTS (see next plots).
Nominal centre frequency = 868.32 MHz
Limit of spectrum bandwidth = 0.25 % of 868.32 MHz = 2170.80 kHz




                      99% bandwidth (kHz)                                  42.672
                    -26 dBc bandwidth (kHz)                                43.835
               Measurement uncertainty (kHz)                               <±0.42




Report No: (NIE)
51368RRF.001                                              Page 15 of 22                       2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




   Section 15.231 Subclause (b) /15.209 / RSS-210 A.1.2. / RSS-Gen. Field strength and Emission limitations
                                            radiated (Transmitter)


SPECIFICATION

The field strength of emissions from intentional radiators shall not exceed the following:

                     Fundamental                  Field strength of fundamental   Field strength of spurious
                   frequency (MHz)                           (µV/m)                   emissions (µV/m)
                     40.66 – 40.70                           2,250                           225
                        70 – 130                             1,250                           125
                        130 - 174                      1,250 to 3,750 **               125 to 375 **
                        174 - 260                            3,750                           375
                        260 - 470                      3,750 to 12,500 **              375 to 1,250 **
                 Above 470                   12,500                           1,250
**: Linear Interpolations. The maximum permitted unwanted emission level is 20dB below the maximum
permitted fundamental level.

Spurious emissions shall be attenuated to the limits shown in the above table or to the general limits shown in
Section 15.209/RSS-Gen, whichever limit permits a higher field strength.
For average radiated emission measurements above 1000 MHz, there is also a limit corresponding to 20 dB above
the indicated values in the table is specified when measuring with peak detector function.




RESULTS:


The field strength is calculated by adding correction factor to the measured level from the spectrum analyser.
This correction factor includes antenna factor, cable loss and pre-amplifiers gain.
The transmission is pulsed so the average values of transmitter fundamental and spurious emissions are
calculated from the measured peak values using the duty cycle correction factor δ as indicated in standard
ANSI C63.10-2013.




Report No: (NIE)
51368RRF.001                                                     Page 16 of 22                                 2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




Computation of duty-cycle correction factor




Number of pulses within 100 ms: 95

Sub-part1:




Report No: (NIE)
51368RRF.001                                          Page 17 of 22   2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456


Sub-part2:




Duty-cycle correction factor calculation.
Sub-part 1
Sub-pulse                  Duration (ms)                           Number of pulses   Sub-pulse    “On
                                                                                      Time” (ms)
1                                    0.3505                        19                 6.6595
2                                    0.4005                        21                 8.4105
3                                    0.8011                        4                  3.2044
4                                    0.7510                        4                  3.0040
                                                                   TOTAL ON TIME      21.2784
                                                                   Sub-part 1:

Sub-part 2
Sub-pulse                            Duration (ms)                 Number of pulses   Sub-pulse    “On
                                                                                      Time” (ms)
1                                    0.3505                        11                 3.8555
2                                    0.4005                        21                 8.4105
3                                    0.8011                        7                  5.6077
4                                    0.7510                        8                  6.0080
                                                                   TOTAL ON TIME      23.8817
                                                                   Sub-part 2:

Sub-part                                              Sub-pulse “On Time” (ms)
1                                                     21.2784
2                                                     23.8817
TOTAL ON TIME:                                        45.1601

Duty cycle correction factor δ = 45.1601 / 100 = 0.4516
δ = 20 log (0.4516) = -6.90 dB


Report No: (NIE)
51368RRF.001                                                      Page 18 of 22                          2016-12-19


  AT4 wireless, S.A.U.
  Parque Tecnológico de Andalucía,
  c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
  España
  www.at4wireless.com · C.I.F. A29 507 456


  Frequency range 30 MHz-1000 MHz (see next plots)


             Frequency (MHz)                   Polarization           Detector         Emission Level        Limits (µV/m)
                                                                                          (µV/m)
                                                                                                           15.231 (b) / 15.209
                     868.322                            V                  Peak           26,091.55         125,000 (101.84
                                                                                                             dBµV/m) / ---
                (Fundamental)


  Calculation for average level

Spurious frequency             Emission Level                   Duty-cycle            Corrected Emission           Limits (µV/m)
      (MHz)                    (dBµV/m) Peak                correction factor δ             Level
                                                                                                                 15.231 (b) / 15.209
                                                                   (dB)               (dBµV/m) Average

     868.322
                                      88.33                        -6.90                    81.43           12,500 (81.94 dBµV/m) / ---
  (Fundamental)



  Measurement uncertainty (dB): ±3.88 dB.



  Frequency range 1 GHz-10 GHz (see next plots)

  Highest spurious levels.

           Frequency (GHz)                  Polarization            Detector          Emission Level         Limits (µV/m)
                                                                                        (dBµV/m)
                                                                                                           15.231 (b) / 15.209
                                                                                                        12,500 (81.94 dBµV/m) /
                  1.73665                           H                 Peak                52.73
                                                                                                           5,000 (74 dBµV/m)
                                                                                                        12,500 (81.94 dBµV/m) /
                  2.60485                           V                 Peak                53.06
                                                                                                           5,000 (74 dBµV/m)
                                                                                                        12,500 (81.94 dBµV/m) /
                  3.47305                           V                 Peak                55.69
                                                                                                           5,000 (74 dBµV/m)
                                                                                                        12,500 (81.94 dBµV/m) /
                  4.34155                           H                 Peak                65.69
                                                                                                           5,000 (74 dBµV/m)
                                                                                                        12,500 (81.94 dBµV/m) /
                  5.21005                           V                 Peak                49.41
                                                                                                           5,000 (74 dBµV/m)




  Report No: (NIE)
  51368RRF.001                                                        Page 19 of 22                                           2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456


Calculation for average level

Spurious frequency Emission Level                         Duty-cycle            Corrected Emission       Limits (µV/m)
      (GHz)        (dBµV/m) Peak                      correction factor δ             Level
                                                                                                       15.231 (b) / 15.209
                                                             (dB)               (dBµV/m) Average

                                                                                                     1,250 (61.94 dBµV/m) /
       3.47305                        55.69                  -6.90                    48.79
                                                                                                        500 (54 dBµV/m)


                                                                                                     1,250 (61.94 dBµV/m) /
       4.34155                        65.69                  -6.90                    58.79
                                                                                                        500 (54 dBµV/m)



All other peak values are below the average limits.

Measurement uncertainty (dB): ±4.87 dB.


Verdict: PASS.




Report No: (NIE)
51368RRF.001                                                    Page 20 of 22                                     2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456




FREQUENCY RANGE 30 MHz-1000 MHz




Note: The peak shown in the plot is the carrier frequency.




Report No: (NIE)
51368RRF.001                                          Page 21 of 22   2016-12-19


AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456



FREQUENCY RANGE 1 GHz to 10 GHz




Report No: (NIE)
51368RRF.001                                          Page 22 of 22   2016-12-19



Document Created: 2016-12-19 12:45:21
Document Modified: 2016-12-19 12:45:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC