 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA




                                                  FCC TEST REPORT

                                                                FOR

                                                          NUM AXES

        CLASSIC DOG FENCE TRANSMITTER/CAT & SMALL DOG FENCE
                            TRANSMITTER

                                              Test Model: PFFUGFIL085

        Additional Model No.: PFFUGFIL061, PFFUGFIL079,PFFUGFIL060




Prepared for                            :    NUM AXES
Address                                 :    745, rue de la Bergeresse ZAC des Aulnaies, OLIVET 45161, France


Prepared by                             :   Shenzhen LCS Compliance Testing Laboratory Ltd
                                            1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an
Address                                 :
                                            District, Shenzhen, Guangdong, China
Tel                                     :   (+86)755-82591330
Fax                                     :   (+86)755-82591332
Web                                     :   www.LCS-cert.com
Mail                                    :   webmaster@LCS-cert.com


Date of receipt of test sample          :    April 02, 2018
Number of tested samples                :    1
Sample number                           :    180402140A
Date of Test                            :    April 02, 2018~May 03, 2018
Date of Report                          :    December 25, 2018




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: U5O-FIL085         Report No.:LCS180402140AEA


                                                            FCC TEST REPORT
                                                         FCC CFR 47 PART 15 C
Report Reference No. ................. : LCS180402140AEA

Date of Issue................................... : Dec 25, 2018

Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                         1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
Address ........................................... :
                                                         Bao’an District, Shenzhen, Guangdong, China
                                                         Full application of Harmonised standards ■
                                                     :
Testing Location/ Procedure ..........                   Partial application of Harmonised standards □
                                                         Other standard testing method □
Applicant’s Name ......................... : NUM AXES
                                                         745, rue de la Bergeresse ZAC des Aulnaies, OLIVET 45161,
Address ........................................... :
                                                         France

Test Specification

Standard ......................................... : FCC CFR 47 PART 15 C / ANSI C63.10: 2013

Test Report Form No. ..................... : LCSEMC-1.0

TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF ..................................... : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
                                                         CLASSIC DOG FENCE TRANSMITTER/CAT & SMALL DOG
Test Item Description. .................. :
                                                         FENCE TRANSMITTER

Trade Mark ..................................... :

Test Model ...................................... : PFFUGFIL085
                                                         DC 15V/150mA by power adapter
Ratings ............................................ :
                                                         Adapter input: AC120V,60Hz
Result ........................................... : Positive



             Compiled by:                                        Supervised by:                            Approved by:




   Calvin Weng/ Administrators                             Dick Su / Technique principal              Gavin Liang/ Manager

  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085           Report No.:LCS180402140AEA


                                                   FCC -- TEST REPORT

                                                                                              December 25, 2018
      Test Report No. :                            LCS180402140AEA
                                                                                                Date of issue




   Test Model..............................         : PFFUGFIL061


                                                        CLASSIC DOG FENCE TRANSMITTER/CAT & SMALL DOG
   EUT.........................................     :
                                                        FENCE TRANSMITTER

   Applicant...............................         : NUM AXES
                                                        745, rue de la Bergeresse ZAC des Aulnaies, OLIVET 45161,
   Address..................................        :
                                                        France
   Telephone...............................         : /

   Fax..........................................    : /


   Manufacturer........................             : NUM AXES
                                                        745, rue de la Bergeresse ZAC des Aulnaies, OLIVET 45161,
   Address...................................       :
                                                        France
   Telephone...............................         : /

   Fax..........................................    : /




                              Test Result                                                        Positive


  The test report merely corresponds to the test sample.
  It is not permitted to copy extracts of these test result without the written permission of the test
  laboratory.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 3 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: U5O-FIL085            Report No.:LCS180402140AEA


                                                 Revision History
         Revision                     Issue Date                            Revisions                        Revised By
           000                     December 25, 2018                       Initial Issue                     Gavin Liang




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 4 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                     FCC ID: U5O-FIL085                   Report No.:LCS180402140AEA


                                                  TABLE OF CONTENTS
   1. GENERAL INFORMATION ................................................................................................................ 6
       1.1. Description of Device (EUT) ...................................................................................................................... 6
       1.2. Support Equipment List .............................................................................................................................. 6
       1.3. External I/O .................................................................................................................................................. 6
       1.4. Description of Test Facility ........................................................................................................................ 6
       1.5. Statement of the measurement uncertainty............................................................................................ 7
       1.6. Measurement Uncertainty.......................................................................................................................... 7
       1.7. Description of Test Modes ......................................................................................................................... 7
   2. TEST METHODOLOGY ...................................................................................................................... 8
       2.1. EUT Configuration ...................................................................................................................................... 8
       2.2. EUT Exercise ............................................................................................................................................... 8
       2.3. General Test Procedures........................................................................................................................... 8
       2.3.1 Conducted Emissions .............................................................................................................................. 8
       2.3.2 Radiated Emissions .................................................................................................................................. 8
   3. CONNECTION DIAGRAM OF TEST SYSTEM............................................................................... 9
       3.1. Justification .................................................................................................................................................. 9
       3.2. EUT Exercise Software .............................................................................................................................. 9
       3.3. Special Accessories.................................................................................................................................... 9
       3.4. Block Diagram/Schematics ....................................................................................................................... 9
       3.5. Equipment Modifications ............................................................................................................................ 9
       3.6. Test Setup .................................................................................................................................................... 9
   4. SUMMARY OF TEST RESULTS ..................................................................................................... 10
   5. POWER LINE CONDUCTED EMISSIONS.................................................................................... 11
   6. RADIATED EMISSION MEASUREMENT...................................................................................... 13
   7. 99% AND 20 DB BANDWIDTH MEASUREMENT ....................................................................... 19
   8. ANTENNA REQUIREMENTS .......................................................................................................... 21
   9. LIST OF MEASURING EQUIPMENT ............................................................................................. 22
   10. TEST SETUP PHOTOGRAPHS .................................................................................................... 23
   11. EXTERIOR HOTOGRAPHS ........................................................................................................... 23
   12. INTERIOR PHOTOGRAPHS ......................................................................................................... 23




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 5 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA



1. GENERAL INFORMATION
1.1. Description of Device (EUT)

                                               CLASSIC DOG FENCE TRANSMITTER/CAT & SMALL
           EUT
                                               DOG FENCE TRANSMITTER
           Test Model                          PFFUGFIL085
           Additional Model(s)                 PFFUGFIL061, PFFUGFIL079, PFFUGFIL060
                                               All the structure, PCB is the same except the model name
           Model Declaration
                                               is different, so no additional model is tested.
           Hardware Version                    CPSSECAR143
           Software Version                    CPELEPRG086 Version Géné-2-H
                                               DC 15V/150mA by power adapter
           Power Supply
                                               Adapter input: AC120V,60Hz
           Wireless technology
           Frequency Range                     20KHz
           Channel Spacing                     N/A
           Channel Number                      1 channel
           Modulation Type                     OOK
           Antenna Description                 External Antenna, 0dBi (Max.)

1.2. Support Equipment List

               Manufacturer                Description               Model            Serial Number           Certificate
            HON KWANG
                                         Power adapter            D7300-01                     --             FCC VOC
          ELECTRIC CO LTD
                 --                              --                     --                     --                   --


1.3. External I/O

               I/O Port Description                            Quantity                                 Cable
                    DC in port                                   1                                       N/A

1.4. Description of Test Facility
     FCC Registration Number. is 254912.
     Industry Canada Registration Number. is 9642A-1.
     ESMD Registration Number. is ARCB0108.
     UL Registration Number. is 100571-492.
     TUV SUD Registration Number. is SCN1081.
     TUV RH Registration Number. is UA 50296516-001
     NVLAP Registration Code is 600167-0
     The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
     16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 6 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA

1.5. Statement of the measurement uncertainty
     The data and results referenced in this document are true and accurate. The reader is cautioned that
     there may be errors within the calibration limits of the equipment and facilities. The measurement
     uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
     “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
     Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. to DIN EN
     ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
     result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
     the device.

1.6. Measurement Uncertainty

                    Test Item                       Frequency Range                      Uncertainty               Note
                                                      9KHz~30MHz                          3.10dB                    (1)
                                                    30MHz~200MHz                          2.96dB                    (1)
            Radiation Uncertainty            :
                                                   200MHz~1000MHz                         3.10dB                    (1)
                                                     1GHz~26.5GHz                         4.00dB                    (1)
           Conduction Uncertainty            :       150kHz~30MHz                         1.63dB                    (1)
             Power disturbance               :      30MHz~300MHz                          1.60dB                    (1)


(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.

1.7. Description of Test Modes
     The EUT operates at 20 KHz. The following operating modes were applied for the related test items.
     All test modes were tested, only the result of the worst case was recorded in the report.
     It was pre-tested on the positioned of each 3 axis. The worst case was found positioned on X-plane.

                                                                               Transmitting Frequency
                                Mode of Operations
                                                                                       (KHz)
                                          OOK                                             20
                                                          For Conducted Emission
                                      Test Mode                                                   TX Mode
                                                           For Radiated Emission
                                      Test Mode                                                   TX Mode


     ***Note: Using a temporary antenna connector for the EUT when the conducted measurements are
     performed.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: U5O-FIL085            Report No.:LCS180402140AEA



2. TEST METHODOLOGY
    All measurements contained in this report were conducted with ANSI C63.10: 2013, American
    National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
    The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
    conducted emissions measurement was performed at Shenzhen LCS Compliance Testing
    Laboratory Ltd.

2.1. EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the
    Commissions requirement and operating in a manner that intends to maximize its emission
    characteristics in a continuous normal application.

2.2. EUT Exercise
    The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of
    the measurements.
    According to its specifications, the EUT must comply with the requirements of the Section 15.201,
    15.203, 15.205, 15.207, 15.209 under the FCC Rules Part 15 Subpart C.

2.3. General Test Procedures

2.3.1 Conducted Emissions
    According to the requirements in Section 6.2 of ANSI C63.10: 2013, AC power-line conducted
    emissions shall be measured in the frequency range between 0.15 MHz and 30MHz using
    Quasi-peak and average detector modes.

2.3.2 Radiated Emissions
    The EUT is placed on a turn table and the turntable shall rotate 360 degrees to determine the
    position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied
    from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by
    changing the polarization of receiving antenna both horizontal and vertical. In order to find out the
    maximum emissions, exploratory radiated emission measurements were made according to the
    requirements in Section 6.3 of ANSI C63.10: 2013.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 8 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA



3. CONNECTION DIAGRAM OF TEST SYSTEM

3.1. Justification

     The system was configured for testing in a continuous transmitting condition.

3.2. EUT Exercise Software


     Powered on the EUT then the EUT will transmit at 20 KHz.

3.3. Special Accessories

     N/A

3.4. Block Diagram/Schematics

     Please refer to the related document

3.5. Equipment Modifications

     Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

3.6. Test Setup

     Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 9 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA


4. SUMMARY OF TEST RESULTS

                               Applied Standard: FCC Part 15 Subpart C
                FCC Rules                      Description Of Test                                        Result
                 §15.203                   Antenna Requirement                                           Compliant
                §15.207(a)            Power Line Conducted Emissions                                     Compliant
          §15.201(a), §15.205(a),
                                     Radiated Emissions Measurement                                      Compliant
          §15.209(a), §15.215(a)
                 §2.1049
                                         99% and 20dB Bandwidth                                          Compliant
                 §15.215


Remark:
Note 1 --- Test results inside test report.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 10 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA



5. POWER LINE CONDUCTED EMISSIONS

5.1 Standard Applicable

     According to §15.207 (a): For an intentional radiator which is designed to be connected to the public
     utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on
     any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts
     (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz).
     The limits at specific frequency range is listed as follows:

         Frequency Range                                                  Limits (dBμV)
               (MHz)                                 Quasi-peak                                       Average
            0.15 to 0.50                              66 to 56                                        56 to 46
             0.50 to 5                                  56                                              46
              5 to 30                                   60                                              50

               * Decreasing linearly with the logarithm of the frequency

5.2 Block Diagram of Test Setup




5.3 Test Results

     PASS.
     The test data please refer to following page.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 11 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA

AC Conducted Emission of charge from power adapter mode @ AC 120V/60Hz @ (worst case)

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report.

  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 12 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA


6. RADIATED EMISSION MEASUREMENT

6.1. Standard Applicable

     According to FCC §15.201 (a) “Intentional radiators operated as carrier current systems, devices
     operated under the provisions of §§15.211, 15.213, and 15.221, and devices operating below 490
     kHz in which all emissions are at least 40 dB below the limits in §15.209 are subject to Suppliers
     Declaration of Conformity pursuant to the procedures in subpart J of part 2 of this chapter prior to
     marketing.”

               Frequencies                              Field Strength                        Measurement Distance
                   (MHz)                              (microvolts/meter)                            (meters)
               0.009~0.490                               2400/F(KHz)                                  300
               0.490~1.705                              24000/F(KHz)                                  30
                1.705~30.0                                    30                                      30
                  30~88                                      100                                       3
                  88~216                                     150                                       3
                 216~960                                     200                                       3
                Above 960                                    500                                       3

6.2. Instruments Setting

     Please refer to of equipment list in this report. The following table is the setting of spectrum analyzer
     and receiver.

    Spectrum Parameter                                       Setting
    Attenuation                                              Auto
    Start Frequency                                          1000 MHz
    Stop Frequency                                           10th carrier harmonic
    RB / VB (Emission in restricted band)                    1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average
    RB / VB (Emission in non-restricted band)                1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average

   Receiver Parameter                                           Setting
   Attenuation                                                  Auto
   Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
   Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
   Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 13 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA

6.3. Test Procedure


     1) Sequence of testing 9 kHz to 30 MHz


     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
     --- If the EUT is a floor standing device, it is placed on the ground.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.

     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna height is 0.8 meter.
     --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
     emissions

     Final measurement:
     --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
     position (0° to 360°) and by rotating the elevation axes (0° to 360°).
     --- The final measurement will be done in the position (turntable and elevation) causing the highest
     emissions with QPK detector.
     --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor,
     margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and
     the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 14 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: U5O-FIL085            Report No.:LCS180402140AEA




    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
    plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in
    peak to find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software
    maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
    meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
    turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
    graph of the premeasurement with marked maximum final measurements and the limit will be stored.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 15 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA

6.4. Block Diagram of Test Setup




     Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
     dB/decade form 3m to 1m.
     Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1m]) (dB);
     Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

6.5. EUT Operation during Test

     The EUT was programmed to be in continuously transmitting mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 16 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA

6.6. Results of Radiated Emissions (9 KHz~30MHz)




     Note:
     The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
     value has no need to be reported.
     Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
     Limit line = specific limits (dBuV) + distance extrapolation factor.

6.7. Results of Radiated Emissions (30 MHz~1000 MHz)


     PASS.
     Only record the worst test result in this report.
     The test data please refer to following page.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 17 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA

Horizontal




Vertical




***Note:
1). Pre-scan all modes and recorded the worst case results in this report (TX).
2). Emission level (dBuV/m) = 20 log Emission level (uV/m).
3). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.

  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 18 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA


7. 99% AND 20 DB BANDWIDTH MEASUREMENT

7.1. Standard Applicable

     According to §15.215, device must be designed to ensure that the 20 dB bandwidth of the emission,
     or whatever bandwidth may otherwise be specified in the specific rule section under which the
     equipment operates, is contained within the frequency band designated in the rule section under
     which the equipment is operated.
     According to §2.1049, The occupied bandwidth, that is the frequency bandwidth such that, below its
     lower and above its upper frequency limits, the mean powers radiated are each equal to 0.5 percent
     of the total mean power radiated by a given emission shall be measured under the following
     conditions as applicable.

7.2. Block Diagram of Test Setup




7.3. Test Procedure

     Use the following spectrum analyzer settings:
     Span = 3 KHz
     RBW = 100 Hz
     VBW = 300 Hz
     Sweep = auto
     Detector function = peak
     Trace = max hold
     The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
     marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function
     to measure 20 dB down one side of the emission. Reset the marker-delta function, and move the
     marker to the other side of the emission, until it is (as close as possible to) even with the reference
     marker level. The marker-delta reading at this point is the 20 dB bandwidth of the emission. If this
     value varies with different modes of operation (e.g., data rate, modulation format, etc.), repeat this
     test for each variation. The limit is specified in one of the subparagraphs of this Section. Submit this
     plot(s).

7.4. Test Results

                               Test Result Of 99% and 20dB Bandwidth Measurement
        Test Frequency                 99% Bandwidth           20dB Bandwidth                                       Limit
             (KHz)                           (Hz)                    (Hz)                                          (MHz)
             20.00                          209.00                  247.00                                        No Limit

Remark:
1. Test results including cable loss;
2. Please refer to following test plots;


  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 19 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: U5O-FIL085            Report No.:LCS180402140AEA




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 20 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: U5O-FIL085            Report No.:LCS180402140AEA



8. ANTENNA REQUIREMENTS

8.1 Standard Applicable

     According to antenna requirement of §15.203, an intentional radiator shall be designed to ensure that
     no antenna other than that furnished by the responsible party shall be used with the device. The use
     of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional
     radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer
     may design the unit so that a broken antenna can be re-placed by the user, but the use of a standard
     antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current
     devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or
     15.221. Further, this requirement does not apply to intentional radiators that must be professionally
     installed, such as perimeter protection systems and some field disturbance sensors, or to other
     intentional radiators which, in accordance with Section 15.31(d), must be measured at the installation
     site. However, the installer shall be responsible for ensuring that the proper antenna is employed so
     that the limits in this Part are not exceeded.

8.2 Antenna Connected Construction


8.2.1. Standard Applicable

     According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than
     that furnished by the responsible party shall be used with the device.

8.2.2. Antenna Connector Construction

     The antenna gain used for transmitting is 0dBi, the EUT use external antenna and a unique antenna
     connector. Please see EUT photo for details.

8.2.3. Results: Compliance.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 21 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: U5O-FIL085            Report No.:LCS180402140AEA


9. LIST OF MEASURING EQUIPMENT
Item          Equipment           Manufacturer    Model No.    Serial No.                                 Last Cal.          Next Cal.
  1          Power Meter               R&S          NRVS        100444                                   2017-06-17         2018-06-16
  2         Power Sensor               R&S        NRV-Z81       100458                                   2017-06-17         2018-06-16
  3         Power Sensor               R&S        NRV-Z32        10057                                   2017-06-17         2018-06-16
         EPM Series Power
 4                                    Agilent      E4419B     MY45104493                                 2017-06-17         2018-06-16
                  Meter
           E-SERIES AVG
 5                                    Agilent      E9301H     MY41495234                                 2017-06-17         2018-06-16
         POWER SENSOR
           ESA-E SERIES
 6           SPECTRUM                 Agilent      E4407B     MY41440754                                 2017-11-18         2018-11-17
             ANALYZER
 7      MXA Signal Analyzer           Agilent      N9020A     MY49100040                                 2017-06-17         2018-06-16
             SPECTRUM
 8                                     R&S           FSP        100503                                   2017-06-17         2018-06-16
             ANALYZER
         3m Semi Anechoic
 9                              SIDT FRANKONIA    SAC-3M      03CH03-HY                                  2017-06-17         2018-06-16
               Chamber
10      Positioning Controller         MF         MF-7082           /                                    2017-06-17         2018-06-16
11       EMI Test Software            AUDIX           E3           N/A                                      N/A                N/A
12       EMI Test Receiver     ROHDE & SCHWARZ      ESR 7       101181                                   2017-06-17         2018-06-16
13           AMPLIFIER              QuieTek     QTK-A2525G   CHM10809065                                 2017-11-18         2018-11-17
14      Active Loop Antenna     SCHWARZBECK     FMZB 1519B       00005                                   2017-06-23         2018-06-22
15         By-log Antenna       SCHWARZBECK      VULB9163      9163-470                                  2017-05-02         2018-05-01
16          Horn Antenna              EMCO          3115          6741                                   2017-06-23         2018-06-22
17         RF Cable-R03m             Jye Bao       RG142        CB021                                    2017-06-17         2018-06-16
18         RF Cable-HIGH            SUHNER     SUCOFLEX 106   03CH03-HY                                  2017-06-17         2018-06-16
19        TEST RECEIVER                R&S          ESCI        101142                                   2017-06-17         2018-06-16
20         RF Cable-CON             UTIFLEX     3102-26886-4    CB049                                    2017-06-17         2018-06-16
21         10dB Attenuator      SCHWARZBECK     MTS-IMP136 261115-001-0032                               2017-06-17         2018-06-16
22          Artificial Mains           R&S         ENV216       101288                                   2017-06-17         2018-06-16
       X-series USB Peak and
23     Average Power Sensor           Agilent     U2021XA     MY54080022                                 2017-10-27         2018-10-26
                 Aglient
        4 CH. Simultaneous
24                                    Agilent      U2531A     MY54080016                                 2017-10-27         2018-10-26
       Sampling 14 Bits 2MS/s
25          Test Software           Ascentest    AT890-SW      20160630                                     N/A                N/A
26         RF Control Unit          Ascentest    AT890-RFB         N/A                                   2017-06-17         2018-06-16




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 22 of 23


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: U5O-FIL085            Report No.:LCS180402140AEA


10. TEST SETUP PHOTOGRAPHS

    Please refer to separated files for Test Setup Photos of the EUT.


11. EXTERIOR HOTOGRAPHS

    Please refer to separated files for External Photos of the EUT.


12. INTERIOR PHOTOGRAPHS

    Please refer to separated files for Internal Photos of the EUT.




                          ------------THE END OF TEST REPORT----------