Test report

FCC ID: U4GJX2WB

Test Report

Download: PDF
FCCID_2438157

FCC Measurement/Technical Report on
WLAN transceiver
incorporated in
Mobile Handheld Computer
Datalogic Joya X2 BASIC
Wifi with DE2011 reader
FCC ID: U4GJX2W
IC: 3862E-JX2W

and
WLAN transceiver
incorporated in
Datalogic Joya X2 PLUS
Wifi + BT with SE4500 reader
FCC ID: U4GJX2WB
IC: 3862E-JX2WB

Report Reference: MDE_DATA_1408_FCCe




Test Laboratory:
Borsigstrasse 11
Germany
7Layers AG
40880 Ratingen

Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7 layers AG                                        Aufsichtsratsvorsitzender                   Registergericht registered in:
Borsigstrasse 11                                   Chairman of the Supervisory Board:           Düsseldorf, HRB 44096
40880 Ratingen, Germany                            Peter Mertel                                 USt-IdNr  VAT No.:
Phone: +49 (0) 2102 749 0                          Vorstand Board:                             DE 203159652
Fax: +49 (0) 2102 749 350                          Dr. H.-J. Meckelburg                         TAX No. 147/5869/0385
www.7Layers.com                                    Dr. H. Ansorge


Table of Contents

0     Applied Standards and Test Summary       3
0.1    Technical Report Summary                3
0.2    FCC and IC Correlation Table            4
0.3    Measurement Summary                     5
0.4    Revision History                        6

1     Administrative Data                      7
1.1    Testing Laboratory                      7
1.2    Project Data                            7
1.3    Applicant Data                          7
1.4    Manufacturer Data                       7

2     Test object Data                         8
2.1    General EUT Description                 8
2.2    EUT Main components                     9
2.3    Ancillary Equipment                     9
2.4    Auxiliary Equipment                     9
2.5    EUT Setups                              9
2.6    Operating Modes                        10
2.7    Special software used for testing      11
2.8    Product labelling                      11

3     Test Results                           12
3.1    Spurious radiated emissions            12
3.2    Band edge compliance                   20

4     Test Equipment                         23

5     Photo Report                           31

6     Setup Drawings                         31




Test report Reference: MDE_DATA_1408_FCCe   Page 2 of 31


0     Applied Standards and Test Summary

0.1   Technical Report Summary

Type of Authorization
Certification for an Intentional Radiator (Digital Device / Spread Spectrum).

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in
47 CFR Ch.1 Parts 2 and 15 (10-1-13 Edition). The following subparts are applicable to
the results in this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification


Part 15, Subpart C – Intentional Radiators

§ 15.201    Equipment authorization requirement

§ 15.207    Conducted limits

§ 15.209    Radiated emission limits; general requirements

§ 15.247    Operation within the bands 902-928 MHz, 2400-2483.5 MHz




Note:
The tests were selected and performed with reference to the FCC Public Notice “Guidance
for Performing Compliance Measurements on Digital Transmission Systems
(DTS)Operating Under §15.247, 558074 D01 DTS Meas Guidance v03r02, 2014-06-05”.

Instead of applying ANSI C63.4–1992 which is referenced in the FCC Public Note, the
newer ANSI C63.4–2009 is applied.



Summary Test Results:

The EUT complied with all performed tests as listed in chapter 0.3 Measurement
Summary.




Test report Reference: MDE_DATA_1408_FCCe                                       Page 3 of 31


0.2   FCC and IC Correlation Table

Correlation of measurement requirements for
DTS devices (e.g. WLAN 2.4/5 GHz) equipment

The following tables show the correlation of measurement requirements for DTS (e.g.
WLAN) equipment and Information Technology Equipment (ITE) from FCC and IC
standards.


DTS equipment

Measurement                      FCC reference                IC reference
Conducted emissions on           § 15.207                     RSS-Gen Issue 3: 7.2.4
AC Mains
Occupied bandwidth               § 15.247 (a) (2)             RSS-210 Issue 8: A8.2 (a)
Peak power output                § 15.247 (b) (3), (4)        RSS-210 Issue 8: A8.4 (4)
Spurious RF conducted            § 15.247 (d)                 RSS-Gen Issue 3: 6;
emissions                                                     RSS-210 Issue 8: A8.5
Spurious radiated emissions      § 15.247 (d);                RSS-Gen Issue 3: 6;
                                 § 15.209 (a)                 RSS-210 Issue 8: A8.5
Band edge compliance             § 15.247 (d)                 RSS-210 Issue 8: A8.5
Power density                    § 15.247 (e)                 RSS-210 Issue 8: A8.2 (b)
Antenna requirement              § 15.203 / 15.204            RSS-Gen Issue 3: 7.1.2
Receiver spurious emissions      –                            RSS-210 Issue 8: 2.3
                                                              RSS Gen Issue 3: 6 *)

*) Receivers which are part of Transceivers are exempted with respect to Notice 2012-DRS0126.



Information Technology Equipment (ITE)

Measurement                      FCC reference                IC reference
Conducted emissions on           § 15.107                     ICES-003 Issue 5: 6.1
AC Mains
Spurious Radiated Emissions      § 15.109                     ICES-003 Issue 5: 6.2




Test report Reference: MDE_DATA_1408_FCCe                                            Page 4 of 31


0.3   Measurement Summary

FCC Part 15, Subpart C                § 15.207
Conducted emissions (AC power line)
The measurement was performed according to ANSI C63.4      2009
                   Setup              Port                 Final Result
                   -                  AC port              N/A

FCC Part 15, Subpart C                § 15.247 (a) (1)
Occupied bandwidth
The measurement was performed according to FCC § 15.31     10-1-13 Edition
                   Setup              Port                 Final Result
                   Setup_01           Temp.ant.connector   Not performed

FCC Part 15, Subpart C                § 15.247 (b) (1)
Peak power output
The measurement was performed according to FCC § 15.31     10-1-13 Edition
                  Setup               Port                 Final Result
                  -                   Temp.ant.connector   Not performed

FCC Part 15, Subpart C                § 15.247 (d), § 15.35 (b), § 15.207
Spurious conducted emissions
The measurement was performed according to ANSI C63.4      2009
                    Setup             Port                 Final Result
                    -                 Temp.ant.connector   Not performed

FCC Part 15, Subpart C                § 15.247 (d), § 15.35 (b), § 15.209
Spurious radiated emissions
The measurement was performed according to ANSI C63.4      2009
                    Setup             Port                 Final Result
                    Setup_01          Enclosure            passed
                    Setup_02          Enclosure            passed

FCC Part 15, Subpart C                § 15.247 (d)
Band edge compliance
The measurement was performed according to FCC § 15.31 /   10-1-13 Edition /
ANSI C63.4                                                 2009
                   Setup              Port                 Final Result
                   Setup_01           Enclosure            passed
                   Setup_02           Enclosure            passed



FCC Part 15, Subpart C                § 15.247 (e)
Power density
The measurement was performed according to FCC § 15.31     10-1-13 Edition
                  Setup               Port                 Final Result
                  -                   Temp.ant.connector   Not performed

N/A    not applicable (the EUT is powered by DC)




Test report Reference: MDE_DATA_1408_FCCe                                 Page 5 of 31


layers
testing for a smarter world




                                                                            /
Responsible for                   f                 Responsible         Q               /(/
Accreditation Scope:          .                     for Test Report:     "




This report contains only the applicable radiated tests.
The applicable conducted tests were tested and reported by another laboratory.




0.4    Revision History

                                      Report version control
 Version         Release date          Change Description                       Version validity
 Initial         2014—10—10            &=                                       Not valid
 RevO1           2014—10—22           test results for Bluetooth removed;       valid
                                      editorial corrections




Test report Reference: MDE_DATA_1408_FCCe                                                     Page 6 of 31


1     Administrative Data

1.1   Testing Laboratory

Company Name:                               7 Layers AG

Address                                     Borsigstr. 11
                                            40880 Ratingen
                                            Germany

This facility has been fully described in a report submitted to the FCC and accepted
under the registration number 96716 .

The test facility is also accredited by the following accreditation organisation:
Laboratory accreditation no.:                DAkkS D-PL-12140-01-01

Responsible for Accreditation Scope:        Dipl.-Ing.   Bernhard Retka
                                            Dipl.-Ing.   Robert Machulec
                                            Dipl.-Ing.   Thomas Hoell
                                            Dipl.-Ing.   Andreas Petz
                                            Dipl.-Ing.   Marco Kullik

Report Template Version:                    2014-08-26


1.2   Project Data

Responsible for testing and report:         Dipl.-Ing. Daniel Gall

Date of Test(s):                            2014-05-27 to 2014-07-25
Date of Report:                             2014-10-22


1.3   Applicant Data

Company Name:                               Datalogic ADC s.r.l.

Address:                                    Via S. Vitalino, 13
                                            40012 Lippo di Calderara di Reno, Bologna
                                            Italy
Contact Person:
                                            Mr. Eucarpio Guarisco


1.4   Manufacturer Data
Company Name:                               Please see applicant data

Address:


Contact Person:




Test report Reference: MDE_DATA_1408_FCCe                                           Page 7 of 31


2     Test object Data

2.1   General EUT Description

Equipment under Test:                  IEEE 802.11b/g/n WLAN transceiver
Type Designation:                      Datalogic Joya X2 and Joya X2 PLUS
Kind of Device:                        Mobile Handheld Computer
(optional)
Voltage Type:                          DC
Voltage Level:                         3.7 V
Tested Modulation Type:                WLAN: DBPSK; OFDM:BPSK



General product description:

The WLAN transceiver is incorporated in a mobile handheld computer, which runs with
Windows Mobile 6 CE.


Specific product description for the EUT:

The focus of this test report is the WLAN transceiver of the Datalogic Joya X2 family,
consequently switched on the IEEE 802.11 b/g/n modes, working in the 2.4 GHz band.
The tested representative variants are “PLUS” including WLAN and Bluetooth and “BASIC”
containing WLAN radio only.


The EUT provides the following ports:

Ports
Enclosure
System-port


The main components of the EUT are listed and described in Chapter 2.2




Test report Reference: MDE_DATA_1408_FCCe                                   Page 8 of 31


2.2    EUT Main components

Type, S/N, Short Descriptions etc. used in this Test Report

      Short            Equipment             Type           Serial No.      HW Status           SW Status
  Description          under Test        Designation
EUT A                WLAN (& BT)        Datalogic Joya    Z14P00157        P/N:                1.80.024.04-
(Code:               transceiver        X2 PLUS Wifi                       911300127              SS000
DE1006006ba01)                          + BT with
                                        SE4500 reader
Remark: EUT A is   equipped with two integral antennas. For Bluetooth an integrated chip antenna with a gain
        of about   2dB is used. For Wifi a single band antenna with a gain of 3.7dB is used.
EUT B                WLAN               Datalogic Joya    Z14P00100        P/N:                1.80.024.04-
(Code:               transceiver        X2 BASIC Wifi                      911300120              SS000
DE1006006da01)                          with DE2011
                                        reader
Remark: EUT B is   equipped with one integral. A single band antenna with a gain of 3.7dB is used.

NOTE: The short description used to simplify the identification of the EUT in this test report.


2.3    Ancillary Equipment

For the purposes of this test report, ancillary equipment is defined as equipment, which
is used in conjunction with the EUT to provide operational and control features to the
EUT. It is necessary to configure the system in a typical fashion, as a customer would
normally use it. But nevertheless Ancillary Equipment can influence the test results.

  Short           Equipment under           Type Designation         Serial No.           HW             SW
Description            Test                                                              Status         Status
-             –                         –                        –                   –              –


2.4    Auxiliary Equipment

For the purposes of this test report, auxiliary equipment is defined as equipment, which
is used temporarily to enable operational and control features especially used for the
tests of the EUT, which is not used during normal operation or equipment that is used
during the tests in combination with the EUT but is not subject of this test report. It is
necessary to configure the system in a typical fashion, as a customer would normally use
it. But nevertheless Auxiliary Equipment can influence the test results.

  Short           Equipment under           Type Designation         Serial No.           HW             SW
Description            Test                                                              Status         Status
-             –                         –                        –                   –              –




2.5    EUT Setups

This chapter describes the combination of EUTs and equipment used for testing. The
rationale for selecting the EUTs, ancillary and auxiliary equipment and interconnecting
cables, is to test a representative configuration meeting the requirements of the
referenced standards.

 Setup        Combination of EUTs                               Description and Rationale
Setup_01            EUT A                   Setup for radiated radio measurements variant “PLUS”
Setup_02            EUT B                   Setup for radiated radio measurements variant “BASIC”



Test report Reference: MDE_DATA_1408_FCCe                                                           Page 9 of 31


2.6     Operating Modes

This chapter describes the operating modes of the EUTs used for testing.


2.6.1    Test Channels

 Band:
 WLAN 2.4 GHz ISM


 2400 - 2483.5 MHz
 Bottom    Middle    Top
    1         6       11
  2412      2437     2462




2.6.2    Datarates

 SISO:
 WLAN b-mode; 20 MHz; 1 Mbit/s; DSSS Modulation
 WLAN g-mode; 20 MHz; 6 Mbit/s; OFDM Modulation
 WLAN n-mode; 20 MHz; 6.5 Mbit/s; OFDM Modulation

The g-mode was selected as “worst case” for OFDM Modulation.
Consequently the testing was performed in b-mode and in g-Mode (and not in n-mode).




Test report Reference: MDE_DATA_1408_FCCe                                  Page 10 of 31


2.7     Special software used for testing

The Windows program “SRU” is used to control the WLAN module which was provided by
the applicant.



2.8     Product labelling

2.8.1    FCC ID label
Please refer to the documentation of the applicant.

2.8.2    Location of the label on the EUT
Please refer to the documentation of the applicant.




Test report Reference: MDE_DATA_1408_FCCe                               Page 11 of 31


3       Test Results

3.1     Spurious radiated emissions

Standard       FCC Part 15, Subpart C

The test was performed according to: ANSI C63.4

3.1.1    Test Description
The test set-up was made in accordance to the general provisions of ANSI C63.4 in a
typical installation configuration. The Equipment Under Test (EUT) was set up on a non-
conductive table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT
support table that is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software ES-K1 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case
orientation of a body-worn or handheld EUT. The final test on all kind of EUTs is
performed at 2 axes. A pre-check is performed while the EUT is powered from a DC
power sourse.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.
Step 1: pre measurement
- Anechoic chamber
- Antenna distance: 10 m
- Detector: Peak-Maxhold
- Frequency range: 0.009 - 0.15 MHz and 0.15 – 30 MHz
- Frequency steps: 0.1 kHz and 5 kHz
- IF–Bandwidth: 0.2 kHz and 10 kHz
- Measuring time / Frequency step: 100 ms
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is to find the maximum
emission level.
- Open area test side
- Antenna distance: according to the Standard
- Detector: Quasi-Peak
- Frequency range: 0.009 – 30 MHz
- Frequency steps: measurement at frequencies detected in step 1
- IF–Bandwidth: 0.2 - 10 kHz
- Measuring time / Frequency step: 100 ms




Test report Reference: MDE_DATA_1408_FCCe                                       Page 12 of 31


2. Measurement above 30 MHz and up to 1 GHz
Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold
- Frequency range: 30 – 1000 MHz
- Frequency steps: 60 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 µs
- Turntable angle range: –180° to 180°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: second measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is, to find out the approximate
turntable angle and antenna height for each frequency.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –180° to 180°
- Turntable step size: 45°
- Height variation range: 1 – 4 m
- Height variation step size: 0.5 m
- Polarisation: horizontal + vertical
After this step, the EMI test system has determined the following values for each
frequency (of step 1):
- Frequency
- Azimuth value (of turntable)
- Antenna height
The last two values have now the following accuracy:
- Azimuth value (of turntable): 45°
- Antenna height: 0.5 m
Step 3: final measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved.
This is necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will
be adjusted. The turntable azimuth will slowly vary by ± 22.5° around this value. During
this action, the value of emission is continuously measured. The turntable azimuth at the
highest emission will be recorded and adjusted. In this position, the antenna height will
also slowly vary by ± 25 cm around the antenna height determined. During this action,
the value of emission is also continuously measured. The antenna height of the highest
emission will also be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 22.5 ° around the determined value
- Height variation range: ± 25 cm around the determined value




Test report Reference: MDE_DATA_1408_FCCe                                        Page 13 of 31


Step 4: final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak (< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results
of the preliminary scan and a chart with the frequencies and values of the results of the
final measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
The Equipment Under Test (EUT) was set up on a non-conductive support at 1.4 m
height in the fully-anechoic chamber. The measurement distance was reduced to 1 m.
The results were extrapolated by the extrapolation factor of 20 dB/decade (inverse
linear-distance for field strength measurements, inverse linear-distance squared for the
power reference level measurements). Due to the fact, that in this frequency range a
double-ridged wave guided horn antenna (up to 18 GHz) and a horn antenna (18–25
GHz) are used, the steps 2-4 are omitted. Step 1 was performed with one height of the
receiving antenna only.
EMI receiver settings:
- Detector: Peak, Average
- IF Bandwidth = 1 MHz

For the data rate in mode n the test is performed as worst-case-check in order to verify
that emissions have a comparable level as found at modes b and g. Typically, the
measurement is performed in the frequency range 1 to 8 GHz but it depends on the
emissions found during the test for the modes b and g. Please refer to the results for the
used frequency range.


3.1.2    Test Requirements / Limits
FCC Part 15, Subpart C, §15.247 (e)

For digitally modulated systems, the peak power spectral density conducted from the
intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band
during any time interval of continuous transmission.
…
The same method of determining the conducted output power shall be used to determine
the power spectral density.




Test report Reference: MDE_DATA_1408_FCCe                                      Page 14 of 31


3.1.3       Test Requirements / Limits
FCC Part 15, Subpart C, §15.247 (d)
... In addition, radiated emissions which fall in the restricted bands, as defined in Section
15.205(a), must also comply with the radiated emission limits specified in Section
15.209(a) (see Section 15.205(c)).

FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

                                    Measurement      Calculated Limits(dBµV/m
Frequency in MHz   Limit (µV/m)                                                  Limits(dBµV/m @10m)
                                    distance (m)              @10m)
0.009 – 0.49       2400/F(kHz)    300      59.1 dB   (48.5 – 13.8) + 30 dB      78.5 – 43.8
0.49 – 1.705       24000/F(kHz)   30       19.1 dB   (48.9 – 23.0) + 10 dB      58.9 – 33.0
1.705 – 30         30             30       19.1 dB   29.5 + 10 dB               39.5

                                      Measurement
Frequency in MHz   Limit (µV/m)                             Limit (dBµV/m)
                                      distance (m)
30 – 88            100            3                  40.0
88 – 216           150            3                  43.5
216 – 960          200            3                  46.0
above 960          500            3                  54.0


§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the
maximum permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)




Test report Reference: MDE_DATA_1408_FCCe                                                 Page 15 of 31


3.1.4     Test Protocol

Temperature:       23–27 °C
Air Pressure:      997-1011 hPa
Humidity:          33–50 %


 WLAN b-Mode; 20 MHz; 1 Mbit/s
           Channel
            Center                          Spurious                                                 Margin
  Ch.     Frequency       Frequency           Level                       RBW          Limit         to Limit
  No.       [MHz]           [MHz]            [dBm]      Detector          [kHz]      [dBµV/m]          [dB]
                                           Joya X2 Variant “PLUS”
 1/78     2412/2480          2333.0            50.4         PK             1000          74.0         23.6
 1/78     2412/2480          2333.0            41.2         AV             1000          54.0         12.8
 1/78     2412/2480          2491.0            56.0         PK             1000          74.0         18.0
 1/78     2412/2480          2491.0            48.6         AV             1000          54.0          5.4
 1/78     2412/2480          4824.0           41.35         PK             1000          74.0         32.65
 1/78     2412/2480          4824.0           34.85         AV             1000          54.0         19.15
 6/39     2437/2441          2358.0            52.2         PK             1000          74.0         21.8
 6/39     2437/2441          2358.0            42.0         AV             1000          54.0         12.0
 6/39     2437/2441          7312.0           44.33         PK             1000          74.0         29.67
 6/39     2437/2441          7312.0           36.36         AV             1000          54.0         17.64
 11/0     2462/2402          1602.0            47.5         PK             1000          74.0         26.5
 11/0     2462/2402          1602.0            37.8         AV             1000          54.0         16.2
 11/0     2462/2402          2383.0            52.8         PK             1000          74.0         21.2
 11/0     2462/2402          2383.0            43.8         AV             1000          54.0         10.2
 11/0     2462/2402          2483.0            50.5         PK             1000          74.0         23.5
 11/0     2462/2402          2483.0            39.3         AV             1000          54.0         14.7
 11/0     2462/2402          7385.0            45.6         PK             1000          74.0         28.4
 11/0     2462/2402          7385.0            38.2         AV             1000          54.0         15.8


Note:   No (further) spurious emissions in the range 20 dB below the limit found.
        During testing also the Bluetooth Transceiver was switched on (BT FSK modulation, 1-DH1).




Test report Reference: MDE_DATA_1408_FCCe                                                     Page 16 of 31


 WLAN b-Mode; 20 MHz; 1 Mbit/s
           Channel
            Center                       Spurious                                                 Margin
  Ch.     Frequency       Frequency        Level                       RBW         Limit          to Limit
  No.       [MHz]           [MHz]         [dBm]      Detector          [kHz]     [dBµV/m]           [dB]
                                        Joya X2 Variant “BASIC”
  1          2412           1235.0          45.3        PEAK            1000         74.0           28.7
  1          2412           2333.0          35.7         AV             1000         54.0           18.4
  1          2412           2333.0          52.1        PEAK            1000         74.0           21.9
  1          2412           2333.0          43.7         AV             1000         54.0           10.3
  1          2412           2387.0          51.5        PEAK            1000         74.0           22.6
  1          2412           2387.0          42.1         AV             1000         54.0           11.9
  1          2412           2491.0          58.1        PEAK            1000         74.0           15.9
  1          2412           2491.0          51.7         AV             1000         54.0           2.3
  1          2412           4824.0          41.8        PEAK            1000         74.0           32.2
  1          2412           4824.0          37.4         AV             1000         54.0           16.6
  6          2437           1235.0          45.5        PEAK            1000         74.0           28.5
  6          2437           1235.0          35.7         AV             1000         54.0           18.3
  6          2437           2356.0          53.7        PEAK            1000         74.0           20.3
  6          2437           2356.0          44.9         AV             1000         54.0           9.1
  6          2437           4874.0          41.3        PEAK            1000         74.0           32.7
  6          2437           4874.0          36.5         AV             1000         54.0           17.5
  6          2437           7310.0          44.6        PEAK            1000         74.0           29.5
  6          2437           7310.0          35.3         AV             1000         54.0           18.7
  11         2462           1235.0          46.1        PEAK            1000         74.0           27.9
  11         2462           1235.0          35.7         AV             1000         54.0           18.4
  11         2462           2383.0          53.1        PEAK            1000         74.0           20.9
  11         2462           2383.0          44.7         AV             1000         54.0           9.3
  11         2462           2487.0          51.2        PEAK            1000         74.0           22.9
  11         2462           2487.0          40.0         AV             1000         54.0           14.0
  11         2462           7387.0          44.1        PEAK            1000         74.0           29.9
  11         2462           7387.0          36.0         AV             1000         54.0           18.0


Note:   No (further) spurious emissions in the range 20 dB below the limit found.
        The measurement was performed from 9 kHz up to 8 GHz because at pre-measurements no significant
        spurious emissions have been found outside this frequency range.




Test report Reference: MDE_DATA_1408_FCCe                                                  Page 17 of 31


 WLAN g-Mode; 20 MHz; 6 Mbit/s
       Channel                                                                                  Margin
        Center               Spurious                                                              to
 Ch.  Frequency Frequency      Level                                  RBW         Limit          Limit
 No.    [MHz]      [MHz]      [dBm]      Detector                     [kHz]     [dBµV/m]         [dB]
                           Joya X2 Variant “PLUS”
 1/78 2412/2480    2338.0       50.9       PEAK                        1000         74.0            23.1
 1/78 2412/2480    2338.0       39.2        AV                         1000         54.0            14.8
 1/78 2412/2480    2390.0       60.6       PEAK                        1000         74.0            13.4
 1/78 2412/2480    2390.0       46.0        AV                         1000         54.0            8.0
 1/78 2412/2480    2488.0       58.3       PEAK                        1000         74.0            15.7
 1/78 2412/2480    2488.0       47.6        AV                         1000         54.0            6.4
 6/39 2437/2441    2360.0       52.7       PEAK                        1000         74.0            21.3
 6/39 2437/2441    2360.0       41.1        AV                         1000         54.0            12.9
 6/39 2437/2441    2483.5       51.7       PEAK                        1000         74.0            22.3
 6/39 2437/2441    2483.5       39.3        AV                         1000         54.0            14.7
 6/39 2437/2441    7312.0       51.1       PEAK                        1000         74.0            22.9
 6/39 2437/2441    7312.0       36.0        AV                         1000         54.0            18.0
 11/0 2462/2402    1602.0       47.3       PEAK                        1000         74.0            26.7
 11/0 2462/2402    1602.0       37.8        AV                         1000         54.0            16.2
 11/0 2462/2402    2383.0       51.1       PEAK                        1000         74.0            22.9
 11/0 2462/2402    2383.0       39.9        AV                         1000         54.0            14.1
 11/0 2462/2402    2483.0       60.8       PEAK                        1000         74.0            13.2
 11/0 2462/2402    2483.0       44.8        AV                         1000         54.0            9.2

Note:   No (further) spurious emissions in the range 20 dB below the limit found.
        The measurements were performed from 1 GHz up to 8 GHz because at pre-measurements no
        significant spurious emissions have been found outside this frequency range.
        During testing also the Bluetooth Transceiver was switched on (BT PSK modulation, 2-DH1).




Test report Reference: MDE_DATA_1408_FCCe                                                   Page 18 of 31


 WLAN g-Mode; 20 MHz; 6 Mbit/s
       Channel                                                                              Margin
        Center               Spurious                                                          to
 Ch.  Frequency Frequency      Level                               RBW         Limit         Limit
 No.    [MHz]      [MHz]      [dBm]     Detector                   [kHz]     [dBµV/m]        [dB]
                          Joya X2 Variant “BASIC”
  1      2412      1235.0       45.1       PEAK                     1000        74.0            28.9
  1      2412      1235.0       35.4        AV                      1000        54.0            18.6
  1      2412      2333.0       51.2       PEAK                     1000        74.0            22.9
  1      2412      2333.0       40.0        AV                      1000        54.0            14.0
  1      2412      2390.0       62.5       PEAK                     1000        74.0            11.5
  1      2412      2390.0       47.0        AV                      1000        54.0            7.0
  1      2412      2493.0       57.7       PEAK                     1000        74.0            16.3
  1      2412      2493.0       46.9        AV                      1000        54.0            7.1
  6      2437      1235.0       45.6       PEAK                     1000        74.0            28.4
  6      2437      1235.0       35.7        AV                      1000        54.0            18.4
  6      2437      2356.0       54.9       PEAK                     1000        74.0            19.2
  6      2437      2356.0       44.2        AV                      1000        54.0            9.8
  6      2437      2483.5       52.6       PEAK                     1000        74.0            21.4
  6      2437      2483.5       40.9        AV                      1000        54.0            13.2
  11     2462      1235.0       45.0       PEAK                     1000        74.0            29.0
  11     2462      1235.0       35.5        AV                      1000        54.0            18.5
  11     2462      2383.0       53.3       PEAK                     1000        74.0            20.7
  11     2462      2383.0       41.8        AV                      1000        54.0            12.2
  11     2462      2483.5       64.5       PEAK                     1000        74.0            9.5
  11     2462      2483.5       47.9        AV                      1000        54.0            6.1

Note:   No (further) spurious emissions in the range 20 dB below the limit found.
        The measurements were performed from 1 GHz up to 8 GHz because at pre-measurements no
        significant spurious emissions have been found outside this frequency range.




Test report Reference: MDE_DATA_1408_FCCe                                               Page 19 of 31


3.2     Band edge compliance

Standard       FCC Part 15, Subpart C

The test was performed according to: ANSI C63.4–2009, FCC §15.31

3.2.1    Test Description
The procedure to show compliance with the band edge requirement is divided into two
measurements:

1. Show compliance of the lower and higher band edge by a conducted measurement.
For the conducted measurement, the Equipment Under Test (EUT) is placed in a shielded
room.
For the lower band edge the EUT is set to transmit as follows:
For a WLAN transmitter working in the 2.4 GHz band on lowest channel:
CH1 = 2412 MHz / CH3 = 2422 MHz for a channel bandwidth of 20 / 40 MHz.
The lower band edge is 2400 MHz for 2.4 GHz band transmitter.
For the higher band edge the EUT is set to transmit as follows:
For a WLAN transmitter working in the 2.4 GHz band on highest channel:
CH11 = 2462 MHz or CH13 = 2472 MHz / CH11= 2462 MHz for a channel bandwidth of
20 / 40 MHz.
The higher band edge is 2483.5 MHz for a 2.4 GHz band transmitter.
Analyzer settings for conducted measurement:
- Detector: Peak
- RBW / VBW = 100 / 300 kHz

2. Showing compliance of the higher band edge falls in to restricted bands by a radiated
measurement.
The radiated emissions measurements are performed in a typical installation
configuration inside the fully anechoic chamber using a horn antenna at 1 m distance.
EMI receiver settings for radiated measurement:
- Detector: Peak, Average
- IF Bandwidth = 1 MHz


3.2.2    Test Requirements / Limits
FCC Part 15.247 (d)
“In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or
digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz
bandwidth within the band that contains the highest level of the desired power, based on
either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. ...
If the transmitter complies with the conducted power limits based on the use of RMS
averaging over a time interval, as permitted under paragraph (b)(3) of this section, the
attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation
below the general limits specified in Section 15.209(a) is not required. In addition,
radiated emissions which fall in the restricted bands, as defined in Section 15.205(a),
must also comply with the radiated emission limits specified in Section 15.209(a) (see
Section 15.205(c)).”




Test report Reference: MDE_DATA_1408_FCCe                                     Page 20 of 31


For the conducted measurement the RF power at the band edge shall be “at least 20 dB
below that in the 100 kHz bandwidth within the band that contains the highest level of
the desired power...”

For the radiated measurement of the higher band edge connected to a restricted band
the limit is “specified in Section 15.209(a)”.


3.2.3     Test Protocol

3.2.3.1    Radiated measurement, higher band edge

Temperature:       23–27 °C
Air Pressure:      997-1011 hPa
Humidity:          33–50 %

 WLAN b-Mode; 20 MHz; 1 Mbit/s
           Channel
            Center                  Spurious                           Limit
  Ch.     Frequency   Frequency       Level                  RBW     [dBµV/m    Margin to Limit
  No.       [MHz]       [MHz]        [dBm]      Detector     [kHz]       ]           [dB]
                                       Joya X2 Variant “BASIC”
  11        2462         2483.5        50.7        PEAK       1000     74.0          23.3
  11        2462         2483.5        39.8         AV        1000     54.0          14.2
                                      Joya X2 Variant “PLUS”
  11        2462        2483.5        50.5       PEAK      1000       74.0           23.5
  11        2462        2483.5        39.3        AV       1000       54.0           14.7


 WLAN g-Mode; 20 MHz; 6 Mbit/s

           Channel
            Center                  Spurious
  Ch.     Frequency   Frequency       Level                  RBW       Limit    Margin to Limit
  No.       [MHz]       [MHz]        [dBm]      Detector     [kHz]   [dBµV/m]        [dB]
                                       Joya X2 Variant “BASIC”
  11        2462        2483.5        64.5       PEAK       1000       74.0           9.5
  11        2462        2483.5        47.9        AV        1000       54.0           6.1
                                       Joya X2 Variant “PLUS”
  11        2462        2483.5        60.8       PEAK        1000      74.0           13.2
  11        2462        2483.5        44.8         AV        1000      54.0            9.2




Test report Reference: MDE_DATA_1408_FCCe                                        Page 21 of 31


3.2.3.2       Measurement Plot (showing the highest value, “worst case”)

 Marker:                2.4835 GHz                          64.52 dBµV/m
 Delta Mk:                    0 Hz                         -16.66 dB


  Level [dBµV/m]
 80


 70


 60


 50


 40


 30


 20


 10


  0
      2.48G             2.485G                    2.49G                    2.495G        2.5G
                                       Frequency [Hz]

      MES DAT_1408_041_pre PK
      MES DAT_1408_041_pre AV
      LIM FCC 15.209 3m     Field Strength AV Limit
      LIM FCC 15.209 3m Peak Field Strength Q-Peak Limit

                                  WLAN mode g variant “BASIC”




Test report Reference: MDE_DATA_1408_FCCe                                           Page 22 of 31


4      Test Equipment
List of Used Test Equipment


    The calibration, hardware and software states are shown for the testing period.


    Test Equipment Anechoic Chamber
     Lab ID:                    Lab 2
     Manufacturer:              Frankonia
     Description:               Anechoic Chamber for radiated testing
     Type:                      10.58x6.38x6.00 m³
                                Calibration Details                                      Last Execution    Next Exec.
                                NSA (FCC)                                                2014/01/09       2017/01/09

     Single Devices for Anechoic Chamber
       Single Device Name       Type                                     Serial Number   Manufacturer

       Air compressor           none                                     -               Atlas Copco

       Anechoic Chamber         10.58 x 6.38 x 6.00 m³                   none            Frankonia
                                Calibration Details                                      Last Execution    Next Exec.
                                FCC listing 96716 3m Part15/18                           2014/01/09       2017/01/08

       Controller Maturo        MCU                                      961208          Maturo GmbH

       EMC camera               CE-CAM/1                                 -               CE-SYS

       EMC camera Nr.2          CCD-400E                                 0005033         Mitsubishi

       Filter ISDN              B84312-C110-E1                                           Siemens&Matsushita

       Filter Universal 1A      BB4312-C30-H3                            -               Siemens&Matsushita


    Test Equipment Auxiliary Equipment for Conducted emissions
     Lab ID:                    Lab 1
     Manufacturer:              Rohde & Schwarz GmbH & Co.KG
     Description:               EMI Conducted Auxiliary Equipment

     Single Devices for Auxiliary Equipment for Conducted emissions
       Single Device Name       Type                                     Serial Number   Manufacturer

       AC Power Source          Chroma 6404                              64040001304     Chroma ATE INC.

       Cable "LISN to ESI"      RG214                                    W18.03+W48.03   Huber&Suhner

       Impedance Stabilization ISN T800                                  36159           Teseq GmbH
       Network
                               Calibration Details                                       Last Execution    Next Exec.
                                Standard Calibration                                     2014/02/06       2016/02/28

       Impedance Stabilization ISN/CDN ENY41                             100002          Rohde & Schwarz GmbH & Co.
       Network, Coupling                                                                 KG
       Decoupling Network

                                Calibration Details                                      Last Execution    Next Exec.
                                Standard calibration                                     2013/03/01       2015/03/31

       Impedance Stabilization ISN/CDN ST08                              36292           Teseq GmbH
       Network, Coupling
       Decoupling Network

                                Calibration Details                                      Last Execution    Next Exec.
                                Standard calibration                                     2014/01/10       2016/01/31




Test report Reference: MDE_DATA_1408_FCCe                                                             Page 23 of 31


    Single Devices for Auxiliary Equipment for Conducted emissions (continued)
      Single Device Name    Type                        Serial Number   Manufacturer
      Impedance Stabilization ISN/CDN T8-Cat6           32187           Teseq GmbH
      Network, Coupling
      Decoupling Network

                            Calibration Details                         Last Execution    Next Exec.
                            Standard Calibration                        2014/01/08       2016/01/31

      One-Line V-Network    ESH 3-Z6                    100489          Rohde & Schwarz GmbH & Co.
                                                                        KG
                            Calibration Details                         Last Execution Next Exec.
                            standard calibration                        2014/06/18       2017/11/30

      One-Line V-Network     ESH 3-Z6                   100570          Rohde & Schwarz GmbH & Co.
                                                                        KG
                            Calibration Details                         Last Execution Next Exec.
                            Standard Calibration                        2013/11/25       2016/11/24

      Two-Line V-Network    ESH 3-Z5                    828304/029      Rohde & Schwarz GmbH & Co.
                                                                        KG
                            Calibration Details                         Last Execution Next Exec.
                            Standart Calibration                        2013/03/01       2015/02/28

      Two-Line V-Network    ESH 3-Z5                    829996/002      Rohde & Schwarz GmbH & Co.
                                                                        KG
                            Calibration Details                         Last Execution Next Exec.
                            Standard Calibration                        2013/03/01       2015/02/28




Test report Reference: MDE_DATA_1408_FCCe                                         Page 24 of 31


   Test Equipment Auxiliary Equipment for Radiated emissions
    Lab ID:                 Lab 2
    Description:            Equipment for emission measurements
    Serial Number:          see single devices

    Single Devices for Auxiliary Equipment for Radiated emissions
      Single Device Name    Type                                  Serial Number    Manufacturer

      Antenna mast          AM 4.0                                AM4.0/180/119205 Maturo GmbH
                                                                  13




      Biconical dipole      VUBA 9117                             9117-108         Schwarzbeck
                            Calibration Details                                    Last Execution    Next Exec.
                            Standard Calibration                                   2012/01/18       2015/01/17

      Broadband Amplifier   JS4-18002600-32-5P                    849785           Miteq
      18MHz-26GHz

      Broadband Amplifier   AFS4-01000400-1Q-10P-4                -                Miteq
      1GHz-4GHz

      Broadband Amplifier   JS4-00101800-35-5P                    896037           Miteq
      30MHz-18GHz

      Cable "ESI to EMI     EcoFlex10                             W18.01-2+W38.01- Kabel Kusch
      Antenna"                                                    2

      Cable "ESI to Horn    UFB311A+UFB293C                       W18.02-2+W38.02- Rosenberger Micro-Coax
      Antenna"                                                    2

      Double-ridged horn    HF 906                                357357/001       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Calibration Details                                    Last Execution Next Exec.
                            Standard Calibration                                   2012/05/18       2015/05/17

      Double-ridged horn    HF 906                                357357/002       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Calibration Details                                    Last Execution Next Exec.
                            Standard Calibration                                   2012/06/26       2015/06/25

      High Pass Filter      4HC1600/12750-1.5-KK                  9942011          Trilithic

      High Pass Filter      5HC2700/12750-1.5-KK                  9942012          Trilithic

      High Pass Filter      5HC3500/12750-1.2-KK                  200035008        Trilithic

      High Pass Filter      WHKX 7.0/18G-8SS                      09               Wainwright

      Horn Antenna          BBHA 9170
      Schwarzbeck 15-26 GHz
      BBHA 9170

      Log.-per. Antenna     HL 562 Ultralog                       100609           Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Calibration Details                                    Last Execution Next Exec.
                            Standard Calibration                                   2012/12/18       2015/12/17

      Log.-per. Antenna     HL 562 Ultralog                       830547/003       Rohde & Schwarz GmbH & Co.
                                                                                   KG

      Loop Antenna          HFH2-Z2                               829324/006       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Calibration Details                                    Last Execution Next Exec.
                            Standard calibration                                   2011/10/27       2014/10/26

      Pyramidal Horn Antenna 3160-09                              00083069         EMCO Elektronik GmbH
      26,5 GHz

      Pyramidal Horn Antenna 3160-10                              00086675         EMCO Elektronik GmbH
      40 GHz

Test report Reference: MDE_DATA_1408_FCCe                                                      Page 25 of 31


    Single Devices for Auxiliary Equipment for Radiated emissions (continued)
      Single Device Name       Type                                    Serial Number   Manufacturer

      Tilt device Maturo       Antrieb TD1.5-10kg                      TD1.5-           Maturo GmbH
      (Rohacell)                                                       10kg/024/3790709




   Test Equipment Auxiliary Test Equipment
    Lab ID:                    Lab 2, Lab 3
    Manufacturer:              see single devices
    Description:               Single Devices for various Test Equipment
    Type:                      various
    Serial Number:             none

    Single Devices for Auxiliary Test Equipment
      Single Device Name       Type                                    Serial Number   Manufacturer

      AC Power Source          Chroma 6404                             64040001304     Chroma ATE INC.

      Broadband Power Divider 1506A / 93459                            LM390           Weinschel Associates
      N (Aux)

      Broadband Power Divider WA1515                                   A855            Weinschel Associates
      SMA

      Digital Multimeter 03    Fluke 177                               86670383        Fluke Europe B.V.
      (Multimeter)
                               Calibration Details                                     Last Execution    Next Exec.
                               Customized calibration                                  2013/12/04       2015/12/03

      Fibre optic link Satellite FO RS232 Link                         181-018         Pontis
      (Aux)

      Fibre optic link         FO RS232 Link                           182-018         Pontis
      Transceiver (Aux)

      Isolating Transformer    LTS 604                                 1888            Thalheimer
                                                                                       Transformatorenwerke GmbH


      Notch Filter Ultra Stable WRCA800/960-6EEK                       24              Wainwright
      (Aux)

      Signal Analyzer          FSV30                                   103005          Rohde & Schwarz GmbH & Co.
                                                                                       KG
                               Calibration Details                                     Last Execution Next Exec.
                               Standard                                                2014/02/10       2016/02/09

      Spectrum Analyser        FSP3                                    836722/011      Rohde & Schwarz GmbH & Co.
                                                                                       KG
                               Calibration Details                                     Last Execution Next Exec.
                               Standard                                                2012/06/13       2015/06/12

      Spectrum Analyser        FSU26                                   200418          Rohde & Schwarz GmbH &
                                                                                       Co.KG
                               Calibration Details                                     Last Execution Next Exec.
                               Standard calibration                                    2013/07/29       2014/07/28

      Vector Signal Generator SMIQ 03B                                 832492/061      Rohde & Schwarz GmbH &
                                                                                       Co.KG




Test report Reference: MDE_DATA_1408_FCCe                                                        Page 26 of 31


   Test Equipment Digital Signalling Devices
    Lab ID:                     Lab 1, Lab 2, Lab 3
    Description:                Signalling equipment for various wireless technologies.

    Single Devices for Digital Signalling Devices
      Single Device Name        Type                                     Serial Number    Manufacturer

      Bluetooth Signalling Unit CBT                                      100589           Rohde & Schwarz GmbH & Co.
      CBT                                                                                 KG
                                Calibration Details                                       Last Execution Next Exec.
                                Standard calibration                                      2011/11/24      2014/11/23

      CMW500                    CMW500                                   107500           Rohde & Schwarz GmbH &
                                                                                          Co.KG
                                Calibration Details                                       Last Execution Next Exec.
                                Standard calibration                                      2014/01/27      2016/01/26

      Digital Radio             CMD 55                                   831050/020       Rohde & Schwarz GmbH & Co.
      Communication Tester                                                                KG
                                Calibration Details                                       Last Execution Next Exec.
                                Standard calibration                                      2011/11/28      2014/11/27

      Universal Radio           CMU 200                                  102366           Rohde & Schwarz GmbH & Co.
      Communication Tester                                                                KG
                                HW/SW Status                                              Date of Start Date of End
                                Hardware:                                                 2007/07/16
                                B11, B21V14, B21-2, B41, B52V14, B52-2,
                                B53-2, B56V14, B68 3v04, PCMCIA, U65V04
                                Software:
                                K21 4v21, K22 4v21, K23 4v21, K24 4v21, K42     4v21,
                                K43 4v21, K53 4v21, K56 4v22, K57 4v22, K58     4v22,
                                K59 4v22, K61 4v22, K62 4v22, K63 4v22, K64     4v22,
                                K65 4v22, K66 4v22, K67 4v22, K68 4v22, K69     4v22
                                Firmware:
                                µP1 8v50 02.05.06
                                ---

      Universal Radio           CMU 200                                  837983/052       Rohde & Schwarz GmbH & Co.
      Communication Tester                                                                KG
                                Calibration Details                                       Last Execution Next Exec.
                                Standard calibration                                      2011/12/07      2014/12/06
                                HW/SW Status                                              Date of Start    Date of End
                                HW options:                                               2007/01/02
                                B11, B21V14, B21-2, B41, B52V14, B52-2,    B53-2,
                                B54V14, B56V14, B68 3v04, B95, PCMCIA,     U65V02
                                SW options:
                                K21 4v11, K22 4v11, K23 4v11, K24 4v11,    K27 4v10,
                                K28 4v10, K42 4v11, K43 4v11, K53 4v10,    K65 4v10,
                                K66 4v10, K68 4v10,
                                Firmware:
                                µP1 8v40 01.12.05
                                ---
                                SW:                                                       2008/11/03
                                K62, K69

      Vector Signal Generator SMU200A                                    100912           Rohde & Schwarz GmbH & Co.
                                                                                          KG




Test report Reference: MDE_DATA_1408_FCCe                                                           Page 27 of 31


   Test Equipment Emission measurement devices
    Lab ID:                   Lab 1, Lab 2
    Description:              Equipment for emission measurements
    Serial Number:            see single devices

    Single Devices for Emission measurement devices
      Single Device Name      Type                                   Serial Number   Manufacturer

      Personal Computer       Dell                                   30304832059     Dell

      Power Meter             NRVD                                   828110/016      Rohde & Schwarz GmbH &
                                                                                     Co.KG
                              Calibration Details                                    Last Execution Next Exec.
                              Standard calibration                                   2014/05/13       2015/05/12

      Sensor Head A           NRV-Z1                                 827753/005      Rohde & Schwarz GmbH &
                                                                                     Co.KG
                              Calibration Details                                    Last Execution Next Exec.
                              Standard calibration                                   2014/05/13       2015/05/12

      Signal Generator        SMR 20                                 846834/008      Rohde & Schwarz GmbH & Co.
                                                                                     KG

      Spectrum Analyzer       ESIB 26                                830482/004      Rohde & Schwarz GmbH & Co.
                                                                                     KG
                              Calibration Details                                    Last Execution Next Exec.
                              Standard Calibration                                   2014/01/07       2016/01/31
                              HW/SW Status                                           Date of Start     Date of End
                              Firmware-Update 4.34.4 from 3.45 during calibration    2009/12/03



   Test Equipment Multimeter 12
    Lab ID:                   Lab 4, Lab 5
    Description:              Ex-Tech 520
    Serial Number:            05157876

    Single Devices for Multimeter 12
      Single Device Name      Type                                   Serial Number   Manufacturer

      Digital Multimeter 12   EX520                                  05157876        Extech Instruments Corp.
      (Multimeter)
                              Calibration Details                                    Last Execution    Next Exec.
                              Customized calibration                                 2013/12/04       2015/12/03




Test report Reference: MDE_DATA_1408_FCCe                                                      Page 28 of 31


   Test Equipment T/A Logger 13
    Lab ID:                  Lab 1, Lab 2, Lab 3
    Description:             Lufft Opus10 TPR
    Type:                    Opus10 TPR
    Serial Number:           13936

    Single Devices for T/A Logger 13
      Single Device Name     Type                     Serial Number   Manufacturer

      ThermoAirpressure       Opus10 TPR (8253.00)    13936           Lufft Mess- und Regeltechnik
      Datalogger 13 (Environ)                                         GmbH

                             Calibration Details                      Last Execution    Next Exec.
                             Customized calibration                   2013/02/07       2015/02/06


   Test Equipment T/H Logger 02
    Lab ID:                  Lab 1
    Description:             Lufft Opus10
    Serial Number:           7489

    Single Devices for T/H Logger 02
      Single Device Name     Type                     Serial Number   Manufacturer

      ThermoHygro Datalogger Opus10 THI (8152.00)     7489            Lufft Mess- und Regeltechnik
      02 (Environ)                                                    GmbH

                             Calibration Details                      Last Execution    Next Exec.
                             Customized calibration                   2013/02/07       2015/02/06


   Test Equipment T/H Logger 03
    Lab ID:                  Lab 3
    Description:             Lufft Opus10
    Serial Number:           7482

    Single Devices for T/H Logger 03
      Single Device Name     Type                     Serial Number   Manufacturer

      ThermoHygro Datalogger Opus10 THI (8152.00)     7482            Lufft Mess- und Regeltechnik
      03 (Environ)                                                    GmbH

                             Calibration Details                      Last Execution    Next Exec.
                             Customized calibration                   2013/02/07       2015/02/06


   Test Equipment T/H Logger 12
    Lab ID:                  Lab 2
    Description:             Lufft Opus10
    Serial Number:           12482

    Single Devices for T/H Logger 12
      Single Device Name     Type                     Serial Number   Manufacturer

      ThermoHygro Datalogger Opus10 THI (8152.00)     12482           Lufft Mess- und Regeltechnik
      12 (Environ)                                                    GmbH

                             Calibration Details                      Last Execution    Next Exec.
                             Customized calibration                   2013/01/07       2015/01/06




Test report Reference: MDE_DATA_1408_FCCe                                       Page 29 of 31


   Test Equipment T/H Logger 15
    Lab ID:                 Lab 4, Lab 5
    Description:            Lufft Opus10
    Serial Number:          13985

    Single Devices for T/H Logger 15
      Single Device Name    Type                     Serial Number   Manufacturer

      ThermoHygro Datalogger Opus10 THI (8152.00)    13985           Lufft Mess- und Regeltechnik
      15 (Environ)                                                   GmbH

                            Calibration Details                      Last Execution    Next Exec.
                            Customized calibration                   2013/01/07       2015/01/06




Test report Reference: MDE_DATA_1408_FCCe                                      Page 30 of 31


5     Photo Report

Please refer to external report.




6     Setup Drawings




Drawing 1: Setup in the Anechoic chamber. For measurements below 1 GHz the ground
           was replaced by a conducting groundplane.




Test report Reference: MDE_DATA_1408_FCCe                              Page 31 of 31



Document Created: 2019-10-05 05:06:22
Document Modified: 2019-10-05 05:06:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC