SAR photos

FCC ID: U4GJX2W

Test Setup Photos

Download: PDF
FCCID_2455797

          The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche
 Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-00.




                                  Appendix for the SAR Test Report
                        Dosimetric Assessment of the
              Portable Device Datalogic Joya X2 PLUS
                                                 (FCC ID: U4GJX2WB / IC: 3862E-JX2WB)

                           According to the FCC Requirements

                                                                                               November 20, 2014


                                                                                                             IMST GmbH
                                                                            Carl-Friedrich-Gauß-Str. 2 - 4
                                                                                         D-47475 Kamp-Lintfort


                                                                                                                  Customer
                                                                                                                 7layers AG
                                                                                                     Borsigstrasse 11
                                                                                                  D-40880 Ratingen




                                                                The test results only relate to the items tested.
        This report shall not bereproduced except in full without the written approval of the testing laboratory.

SAR_Report_7layers_60320_6140261_FCC_WiFi_Body_Joya_X2PLUS_Pictures_V2                                                   Page 1 of 5


                                                       SAR_Report_7layers_60320_6140261_FCC_WiFi_Body_Joya_X2PLUS_Pictures_V2       Page 2 of 5


                                                       Compliance Statement

                                                       The Datalogic Joya X2 PLUS handheld is in compliance with the following standards for
                                                       uncontrolled exposure:
                                                             47 CFR § 2.1093 [47CFR],
                                                             IEEE Std. C95.1 - 1999 [C95.1-1999],
                                                             The latest version of all relevant FCC OET KDB Procedures
                                                       SAR assessment in body worn configuration was conducted with a closest distance of
                                                       0 mm between the housing of the device and the flat phantom.

                                                       According to manufacturer information the assessed Datalogic Joya X2 PLUS (FCC:
                                                       U4GJX2WB / IC: 3862E-JX2WB) is technical identical with the Joya X2 (FCC: U4GJX2W /
                                                       IC: 3862E-JX2W) except of the integrated Bluetooth module.

                                                       Both device variants use identical motherboards but in case of Datalogic Joya X2 PLUS
                                                       the components related to Bluetooth are assembled and in case of Joya X2 not.
                                                       Accordingly the Datalogic Joya X2 PLUS was selected as worst case hardware
                                                       configuration. Since the output power for Bluetooth module is below the threshold, SAR
                                                       assessment for Bluetooth is not applicable. Therefore, it is deemed that the Joya X2 is
                                                       also in compliance with the above mentioned measurements standards.

                                                       Subject of Investigation
SAR_Report_FCC_DECT_WiFI_Head_Body_1.0/10.12.2013/AR




                                                                               Fig. 1: Pictures of the device under test.


                                                       SAR_Report_7layers_60320_6140261_FCC_WiFi_Body_Joya_X2PLUS_Pictures_V2                                        Page 3 of 5


                                                       The maximum result of SAR for the Joya X2 PLUS is as follows:

                                                                                                  WORST CASE SAR RESULTS


                                                               Frequency                        Phantom        Fig      Measured            Reported           SAR Limit
                                                                                        CH
                                                                  [MHz]                          Config.       No.    SAR1g [W/kg]        SAR1g [W/kg]               [W/kg]


                                                        IEEE 802.11 b        2462       11        Pos. 4       1           0.714              0.748            1.6       PASS




                                                       prepared by: ........................................    reviewed by: .....................................

                                                                          Alexander Rahn                                           André van den Bosch
                                                                          test engineer                                            quality assurance engineer



                                                       7.9      Pictures of the Device under Test
                                                       Figure 7 shows the device under test.
SAR_Report_FCC_DECT_WiFI_Head_Body_1.0/10.12.2013/AR




                                                                                Fig. 7:      Device under test Datalogic Joya X2 PLUS.


                                                       SAR_Report_7layers_60320_6140261_FCC_WiFi_Body_Joya_X2PLUS_Pictures_V2            Page 4 of 5


                                                       7.10   Test Positions for the Device under Test

                                                       Fig. 8 – 11 show the test positions for the SAR measurements.




                                                              Fig. 8:   Body worn configuration, position 1, front side towards the phantom.
SAR_Report_FCC_DECT_WiFI_Head_Body_1.0/10.12.2013/AR




                                                              Fig. 9:   Body worn configuration, position 2, back side towards the phantom.


                                                       SAR_Report_7layers_60320_6140261_FCC_WiFi_Body_Joya_X2PLUS_Pictures_V2          Page 5 of 5




                                                              Fig. 10: Body worn configuration, position 3, left side towards the phantom.
SAR_Report_FCC_DECT_WiFI_Head_Body_1.0/10.12.2013/AR




                                                             Fig. 11: Body worn configuration, position 4, right side towards the phantom.



Document Created: 2014-11-21 15:26:16
Document Modified: 2014-11-21 15:26:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC