5GHz report JNG B GUN radiated

FCC ID: U4GJNGW

Test Report

Download: PDF
FCCID_3211621

                                    PARTIAL TEST REPORT
                                       No.: 2-20842790-15-8b



                                                                According to:
                                                             FCC Regulations
                                                          Part 15.407, Part 15.207

                                                               IC-Regulations
                                                              RSS-Gen, Issue 4
                                                              RSS-247, Issue 1



                                                                 for

                                                 Datalogic ADC S.r.l.

                                              JOYA TOUCH
                                      Type:B00AN00HL0GT0W7-GRR
                                                         FCC-ID: U4GJNGW
                                                          IC: 3862E-JNGW
                                                         PMN: JOYA TOUCH
                                                          HVIN: JNG B GUN



                                             Laboratory Accreditation and Listings




                                                                                                       Voluntary Controls for
                                                                               Industry Canada      Electromagnetic Emissions

                                                                              Reg. No.: 3462D-2             Reg. No.:
                                                       MRA US-EU 0003         Reg. No.: 3462D-3          R-2666 C-2914,
                                                                                                         T-1967, G-301




                                       accredited according to DIN EN ISO/IEC 17025
                                                     CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                              Page 1 of 32
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written
approval of the testing laboratory                                                  © Copyright: All rights reserved by CETECOM


Test Report 2-20842790-15-8b, Page 2 of 32


Table of contents
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. Tests measurement overview according of US CFR Title 47, Subpart 15C and Canada RSS-Standards: ...... 3
  1.2. Attestation:....................................................................................................................................................... 4
2. ADMINISTRATIVE DATA ............................................................................................................................... 5
  2.1. Identification of the testing laboratory ............................................................................................................. 5
  2.2. Test location .................................................................................................................................................... 5
  2.3. Organizational items ........................................................................................................................................ 5
  2.4. Applicant’s details ........................................................................................................................................... 5
  2.5. Manufacturer’s details ..................................................................................................................................... 5
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 6
  3.1. Technical 5GHz W-LAN data of main EUT declared by applicant ................................................................ 6
  3.2. IEEE 802.11 OVERVIEW: MODULATION AND DATA RATES .............................................................. 7
  3.3. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 7
  3.4. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 7
  3.5. EUT set-ups ..................................................................................................................................................... 7
  3.6. EUT operating modes ...................................................................................................................................... 8
  3.7. EUT power level configurations ...................................................................................................................... 8
  3.8. Configuration of cables used for testing .......................................................................................................... 8
4. DESCRIPTION OF TEST SYSTEM SET-UP’S .............................................................................................. 9
  4.1. Test system set-up for conducted measurements on antenna port ................................................................... 9
  4.2. Test system set-up for radiated magnetic field measurements below 30 MHz ................................................ 11
  4.3. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz ............................................... 12
  4.4. Test system set-up for radiated electric field measurement above 1 GHz ....................................................... 13
5. MEASUREMENTS ............................................................................................................................................. 14
  5.1. Duty-Cycle....................................................................................................................................................... 14
  5.2. RF-Parameter - Transmitter Peak output power (conducted and radiated) ...................................................... 15
  5.3. RF-Parameter - Power Spectral Density .......................................................................................................... 17
  5.4. General Limit - Radiated field strength emissions below 30 MHz .................................................................. 19
  5.5. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz .............................................................. 21
  5.6. General Limit - Radiated emissions, above 1 GHz .......................................................................................... 23
  5.7. General Limit - Band-edge compliance measurements ................................................................................... 25
  5.8. Measurement uncertainties .............................................................................................................................. 27
6. ABBREVIATIONS USED IN THIS REPORT ................................................................................................. 28
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 28
8. INSTRUMENTS AND ANCILLARY ................................................................................................................ 29
  8.1. Used equipment “CTC” ................................................................................................................................ 29
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................. 32

Table of annex                        The listed attachments are an integral part of this report                                                               Total pages
Annex 1: Test result diagrams (separate document) TR2-20842790-15-8b-A1                                                                                               77
Annex 2: External photographs of EUT (separate document) TR2-20842790-15-8b-A2                                                                                          6
Annex 3: Internal photographs of EUT (separate document) TR2-20842790-15-8b-A3                                                                                        12
Annex 4: Test set-up photographs (separate document) TR2-20842790-15-8b-A4                                                                                            12
Tune-up procedure for SSD45_JOYA TOUCH Basic_rev20160621 (supplied by applicant)                                                                                        2
JOYANG_TEST-TOOLS_QUICK_START_INSTRUCTIONS_REV20160530 (supplied by applicant)                                                                                        41
JOYANG_ WLAN Antenna Final Report (22-Feb-2016) (supplied by applicant)                                                                                               11
Operational Description_JOYA TOUCH_20160530_rev05 (supplied by applicant)                                                                                             10

TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 3 of 32


1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or samples of
the type of the item presented to tests.
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does
not assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests. Also we refer on special conditions which the applicant should
fulfill according §2.927 to §2.948, special focus regarding modification of the equipment and availability of
sample equipment for market surveillance tests.

The presented Equipment Under Test (in this report, hereinafter referred as EUT) supports radiofrequency technologies
with WLAN technology and operating frequency range at 5150 to 5850 GHz according to IEEE 802.11 a/ac. Other
implemented wireless technologies were not considered within this test report.
The build-in W-LAN module is already approved with FCC ID: SQG-SSD45N and IC:3147A-SSD45N.

Following test cases have been performed to show compliance with valid Part 15.209/15.407 of the FCC CFR Title 47
Rules, Edition 4th November 2015 and IC RSS-247 Issue 1/RSS-Gen Issue 4 standards.

1.1. Tests measurement overview according of US CFR Title 47, Subpart 15C and Canada
RSS-Standards:
                                                 References and Limits                           EUT
                                                                                        EUT
   Test cases           Port         FCC          RSS-                                            op.       Result
                                                                  Test limit           set-up
                                   Standard     Standard                                         mode
                                                      TX-Mode
                       Antenna
  99% occupied                                  RSS-Gen,
                       terminal    2.1049(h)                  99% Power bandwidth         --       --      Remark 1.)
   bandwidth                                     Issue 4
                     (conducted)
                                                               No pass/fail criteria
                       Antenna
                                                              To be reported accord.
   Duty-Cycle          terminal        --          --                                     2        1       Remark 4.)
                                                              KDB789033 or ANSI
                     (conducted)
                                                                  C63.10:2013
                                                RSS-247,
                                                             (1) lesser of 200mW or
                                                 Issue 1
                                                                 10dBm+10logB
                       Antenna                   chapter
   Maximum                         §15.407(a)                (2): lesser of 250mW or                         Pass
                       terminal                  6.2.1(1)                                 2        1
  output power                      (1)(2)(3)                    11dBm+10logB                              Remark 4.)
                     (conducted)                 6.2.2(1)
                                                             (3): lesser of 250mW or
                                                 6.2.3(1)
                                                                 11dBm+10logB
                                                 6.2.4(1)
                                                RSS-247,
                                                 Issue 1
                       Antenna                   chapter        (1): 10dBm/MHz
   Peak Power                      §15.407(a)                                                                Pass
                       terminal                  6.2.1(1)       (2): 11dBm/MHz            2        1
 Spectral density                   (1)(2)(3)                                                              Remark 4.)
                     (conducted)                 6.2.2(1)       (3): 11dBm/MHz
                                                 6.2.3(1)
                                                 6.2.4(1)
                                                RSS-247,
                                                 Issue 1
                       Antenna                   chapter                                                     See
  Antenna gain                     §15.407(a)                 < 6dBi or reduction of
                       terminal                  6.2.1(1)                                 --       --     Applicant’s
  information                       (1)(2)(3)                 power/power density
                     (conducted)                 6.2.2(1)                                                 declaration
                                                 6.2.3(1)
                                                 6.2.4(1)




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 4 of 32

   General field             Enclosure +                                                 FCC/IC: Emissions in
     strength                                            §15.407(6)
    emissions
                               Inter-                    §15.407(b)
                                                                                      restricted bands must meet
                             connecting                                                the general field-strength             1              1                   Pass
      within                                              §15.205      RSS-247,
                               cables                                                        radiated limits
    restricted                                            §15.209       Issue 1
                                 (radiated)                                          IC: Chapter 8.9 Table 4+5+6
      bands                                                             chapter
                                                                        6.2.1(2)     Emissions in restricted bands
                                                          §15.205       6.2.2(2)     must meet the general field-
                                                                                                                              1              1                   Pass
                                                          §15.209       6.2.3(2)       strength radiated limits
                             Enclosure +                                6.2.4(2)         chapter 8.9 Table 6
     Band-Edge                 Inter-                                                 Out-of-band emission EIRP
     compliance              connecting                                                   < -27dBm/MHz or
       radiated                cables                                 RSS-Gen.,
                                                                                            -17dBm/MHz
                                 (radiated)              §15.407(b)    Issue 4                                                1              1                   Pass
                                                                                            If applicable
                                                                                      (EIRP>200mW): Elevation
                                                                                       Mask of radiation pattern

                                                                                               IC: A9.3
      Dynamic                   Antenna                                RSS-247,
                                                                                             (a) General
     frequency                  terminal                  §15.407       Issue 1                                               --             --             Remark 2.)
                                                                                     (b) Operational requirements
  selection (DFS)             (conducted)                             chapter 6.3
                                                                                                   --

     AC-Power                                                                               FCC §15.107
                                                                       RSS-Gen,
      Lines                                                                                 class B limits
                               AC-Power                                 Issue 4:
                                                          §15.207                           §15.207 limits                    --             --             Remark 3.)
                                 lines                                Chapter 8.8,
     Conducted
                                                                        Table 3
     Emissions                                                                               IC: Table 3
Remark:
1.) Please refer integrated SSD45N W-LAN Module’s reports
     FCC ID: SQG-SSD45N Report No.FR442904-01AN Version Rev.01, issued Sep. 15, 2015
     Report No.FR442904-01AI Version Rev.01, issued Sep. 15, 2015
     IC:3147A-SSD45N Report No.CR442904-02AN Version Rev.01, issued Nov. 03, 2015
2.) Please refer separate Report No.1-1858_16-02-03 issued on 25.05.2016
3.) Please refer separate test report TR2-20842790-15-10d, performed on EUT with FCC-ID: U4GJNGWB and IC: 3862E-JNGWB due to same
  charging circuit design – see applicants documents
4.) Conducted Tests performed only on Worst-Case JOYA TOUCH Variant Type: P00AN04HL0GT0W7-GRR
  (see test report TR2-20842790-15-10b)


                 RF-Exposure Evaluation (separation distance user to RF-radiating element greater 20cm)

                                                                      References & Limits                                              EUT
                                                                                                                       EUT            opera-
    Test cases                    Port                     FCC                                                                                              Result
                                                                         RSS Section           Test Limit             set-up           ting
                                                         Standard                                                                     mode
                                                                                                RF-Field
                              Cabinet                                                       Strength Limits:
       Radio
                                 +                                                           FCC: “general                                               See separate
    frequency                                        §1.1310(b)
                               Inter-                                      RSS-102             population/                                                test report
     radiation                                        §2.1091                                                             1                1
                             connecting                                     Issue 5           uncontrolled”                                              1-1858_16-
     exposure                                         §2.1093                                                                                               01-04
                               cables                                                         environment
  requirements
                               (radiated)                                                        Table 1
                                                                                               IC: Table 4
1.2. Attestation:
I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct
to my best knowledge and belief to Industry Canada standards. All requirements as shown in above table are met in accordance with enumerated
standards.
                                                                                                                                       Digitally signed by christian.
                                                                                                                                       lorenz@cetecom.com
                                                                                                                                       DN: cn=christian.
                                                                                                                                       lorenz@cetecom.com
                                                                                                                                       Date: 2016.10.31 11:17:12
                                                                                                                                       +01'00'
......................................................                                                       ....................................................
Dipl.-Ing. Rachid Acharkaoui                                                                                         Dipl:-Ing. Christian Lorenz
Responsible for test section                                                                                           Responsible for test report



TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 5 of 32


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report :                                         Dipl:-Ing. Christian Lorenz
Project leader:                                                       Dipl.-Ing. V. Krueger
Receipt of EUT:                                                       2016-02-29
Date(s) of test:                                                      2016-03-02 to 2016-10-10
Date of report:                                                       2016-10-12
           -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     Datalogic ADC S.r.l.
Address:                                                              Via S. Vitalino, 13
                                                                      40012, Lippo di Calderara di Reno (BO)

                                                                      ITALY
Contact person:                                                       Mr. Eucarpio Guarisco

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 6 of 32


3. Equipment under test (EUT)
3.1. Technical 5GHz W-LAN data of main EUT declared by applicant
                       U-NII 1         Ch. 36 to Ch. 48 (Nominal 20MHz signal bandwidth)
                       (5150-5250MHz)  Ch. 38 to Ch. 46 (Nominal 40MHz signal bandwidth)
                       U-NII2A         Ch. 52 to Ch. 64 (Nominal 20MHz signal bandwidth)
 Frequency range       (5250-5350MHz)  Ch. 54 to Ch. 62 (Nominal 40MHz signal bandwidth)
 and channels          U-NII 2C        Ch. 100 to 140 (Nominal 20MHz signal bandwidth)
                       (5470-5725MHz)  Ch. 102 to 134 (Nominal 40MHz signal bandwidth)
                                       Ch. 149 to 165 (Nominal 20MHz signal bandwidth)
                       U-NII-3
                                       Ch. 151 to 159 (Nominal 40MHz signal bandwidth)
                                               BPSK
                                               QPSK
 Type of modulation (packet types)             16-QAM
                                               64-QAM
                                               256-QAM
                                       20MHz bandwidth: 36/40/44/48/52/56/60/64/100/104/108/112/116
 Number of channels
                                      132/136/138/140/149/153/157/161/165
 (USA/Canada -bands)
                                       40MHz bandwidth: 38/46/54/62/102/110/118/134/151/159
                                       Integrated
 Antenna Type                          External, no RF- connector
                                       External, separate RF-connector
                                      According to Applicant’s declaration
                                      5150 to 5250 MHz: 5.88 dBi
 Antenna Gain                         5250 to 5350 MHz: 5.88 dBi
                                      5470 to 5700 MHz: 5.88 dBi
                                      5725 to 5850 MHz: 5.88 dBi
                                       W-LAN 2.4 GHz(not tested within this test report)
                                       Bluetooth©(not tested within this test report)
 Installed options
                                       NFC (not tested within this test report)
                                       battery charging option (WPC) (not tested within this test report)
                                       Internal battery Li-Io 3.41V DC to 4.35 V DC (nominal 3.75 V DC)
 Power supply                          over AC/DC adapter: 120V/60 Hz
                                       DC power only:
 Special EMI components               --
 EUT sample type                       Production  Pre-Production  Engineering
 Firmware                              for normal use                       Special version for test execution
 FCC label attached                    yes              no
Please refer Applicants declaration for further details




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 7 of 32

3.2. IEEE 802.11 OVERVIEW: MODULATION AND DATA RATES
The modulations and data rates defined for 802.11 a/n transmitters are identified in the table below. Also it shows
which operational mode is possible for the device under test (EUT) according applicant’s information.

                                       802.11a-Mode (OFDM system)
  Brutto data rate [MBps]               Modulation type of subcarriers                           Supported by EUT
            6/9                                      BPSK                                              Yes
           12 /18                                    QPSK                                              Yes
           24 / 36                                 16-QAM                                              Yes
           48 / 54                                 64-QAM                                              Yes
Remark: 52 sub-carriers which can be modulated at different data-rates.


                                                802.11n-Mode (OFDM)
             Brutto data rate [MBps]                       Modulation type                       Supported by EUT
   7.2/14.4/21.7/28.9/43.3/57.8/65/72.2 Mbps        HT20 (MCS0..MCS7)                                  Yes
   14.444/28.889/43.333/57.778/86.667/              HT20 (MCS8..MCS15)
                                                                                                       No
   115.556/130/144.444 Mbps
   15/30/45/60/90/120/135/150 Mbps                    HT40 (MCS0..MCS7)                                No
   30/60 Mbps                                         HT40 (MCS8..MCS9)                                No
   90/120/180/240/270/300 Mbps                        HT40 (MCS10..MCS15)                              No



3.3. EUT: Type, S/N etc. and short descriptions used in this test report

 Short
                                                                   S/N                HW                   SW
 descrip-            EUT                      Type
                                                              serial number      hardware status      software status
 tion*)
                                                                                                          SW
                                                                                    Beta HW
                                      B00AN00HL0GT0                                                  Version:WEC7
 EUT A          JOYA TOUCH                                     Z16P00218             Version
                                         W7-GRR                                                        Firmware
                                                                                 P/N: 911350024
                                                                                                      Version: 2.16
*) EUT short description is used to simplify the identification of the EUT in this test report


3.4. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

    AE
   short                                                             S/N              HW                   SW
 descrip-    Auxiliary Equipment               Type             serial number    hardware status      software status
  tion *)
   AE 1                --                        --                   --                 --                 --
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.


3.5. EUT set-ups

 EUT set-up
                       Combination of EUT and AE                                      Remarks
   no.*)

    set. 1                         EUT A                                   Radiated measurements Set-up

    set. 2                   EUT A + Cable 1                               Conducted measurements Set-up
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 8 of 32

3.6. EUT operating modes

    EUT
                      Description of
  operating                                                     Additional information
                     operating modes
 mode no.*)
                                   With help of installed Datalogic test firmware version 2.16 a continuous TX-
                                   a/n (HT20) Mode can be established on
    op. 1         TX- Mode
                                   -desired channels, modulation data rates in LRU Application
                                   -maximum 90% power level in LMU application.
*) EUT operating mode no. is used to simplify the test report.



3.7. EUT power level configurations

    EUT
                      Description of
  operating                                                     Power level information
                     operating modes
 mode no.*)
                                       With help of installed Datalogic test firmware version 2.16 maximum 90%
                                       power level in LMU application is configured for all measurements included
                                       in this report.
     op. 1             TX- Mode
                                       This Power level will now be considered as a Nominal Power level
                                       throughout this report & shall be used for compliance purposes.


3.8. Configuration of cables used for testing
  Cable
                                                                     S/N             HW            Cable length
 number                 Item                   Type
                                                                serial number   hardware status
 Cable 1        RF –SMA Cable                    --                   --                 --             --




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 9 of 32


4. Description of test system set-up’s
4.1. Test system set-up for conducted measurements on antenna port
Conducted Set-up W1

                                      W-LAN conducted RF-Setup 1 (W1 Set-up)

 General description:              The EUT‘s RF-signal is coupled out by a suitable antenna coupling connector (1). The
                                   signal is first attenuated (2) then connected to the power meter (3) for conducted power
                                   measurements. The specific attenuation loss is determined prior to the measurement
                                   within a set-up attenuation measurement. These are then taken into account by correcting
                                   the measurement readings.
 Schematic:




 Testing method:                   ANSI C63.10: 2013 Chapter 12.3.3.1+ FCC KDB 789033v01r03

 Used Equipment                      Passive Elements        Test Equipment        Remark:

                                    20 dB Attenuator      Power Meter            See List of equipment under each test
                                    Low loss RF-          DC-Power Supply        case and chapter 8 for calibration info
                                     cables
                                                           Spectrum-Analyser


 Measurement uncertainty           See chapter 5.8




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 10 of 32

Conducted Set-up W2

                                      W-LAN conducted RF-Setup 2 (W2 Set-up)

 General description:              The EUT‘s RF-signal is coupled out by a suitable antenna coupling connector (1). The
                                   signal is first attenuated (2) then connected to spectrum-analyzer (4) for RF-conducted
                                   measurements. The specific attenuation loss is determined prior to the measurement
                                   within a set-up attenuation measurement. These are then taken into account by correcting
                                   the measurement readings of the spectrum-analyzer.
 Schematic:




 Testing method:                   ANSI C63.10:2013, FCC KDB 789033v01r03

 Used Equipment                      Passive Elements        Test Equipment        Remark:

                                    20 dB Attenuator      Power Meter            See List of equipment under each test
                                    Low loss RF-          DC-Power Supply        case and chapter 8 for calibration info
                                     cables
                                                           Spectrum-Analyser


 Measurement uncertainty           See chapter 5.8


 Testing method for DTS-           ANSI C63.10: 2013 Chapter 11.9.2.3.1+ FCC KDB 789033v01r03
 devices:




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 11 of 32

4.2. Test system set-up for radiated magnetic field measurements below 30 MHz

 Specification:              ANSI C63.10-2013 chapter 6.4 (§6.4.4.2)

 General Description:        Evaluating the radiated field emissions are done first by an exploratory emission
                             measurement and a final measurement for most critical frequencies determined.
                             The loop antenna was placed at 1 m height above ground plane and 3 m
                             measurement distance from set-up for investigations. Because of reduced
                             measurement distance, correction data were applied, as stated in chapter “General
                             Limit - Radiated field strength emissions below 30 MHz“. The tests are performed
                             in the semi anechoic room recognized by the regulatory commission.

 Schematic:




 Testing method:             Exploratory, preliminary measurement                 Final measurement on critical frequencies
                             The EUT and it’s associated accessories are          Based on the exploratory measurements, the most
                             placed on a non-conductive position manipulator      critical frequencies are re-measured by main-
                             (tipping device) of 0.8 m height which is placed     taining the EUT’s worst-case operation mode,
                             on the turntable. By rotating the turntable (step    cable position, etc.
                             90°, range 0°to 360°) and the EUT itself either on
                             3-orthogonal axis (portable equipment) or 2-         First a frequency zoom around the critical
                             orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                             EUT), the emission spectrum was recorded. The        precisely. After this step, for all identified critical
                             loop antenna was moved at least to                   frequencies, the maximum peak was determined.
                             2-perpendicular axes (antenna vector in direction
                             of EUT and parallel to EUT) in order to maximize     Following parameters were varied: the turntable
                             the emissions. The results are documented in a       angle continuously in the range 0 to 360 degree,
                             diagram. Critical frequencies (low margin to         the EUT itself either over 3-orthogonal axis (not
                             limit) are saved within a data reduction table for   defined usage position) or 2-orthogonal axis
                             further investigations. If various operating modes   (defined usage position).
                             are supported, further investigations are made to
                             find the worst-case. Also the interconnection        On the determined worst-case position, a final
                             cables and equipment position were varied in         measurement with necessary bandwidth and
                             order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                    EC = ER + AF + CL + DF - GA               AF =Antenna factor
                                                                       CL = Cable loss
                             M = LT-EC                                 DF= Distance correction factor
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA= Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.

 Distance correction:
                             Reference for applied correction (extrapolating) factors due to reduced
                             measurement distance:
                             ANSI C63.10:2013, §6.4.4.2 - Equations (2) + (3) + (4)




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 12 of 32

4.3. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz


 Specification:              ANSI C63.4-2014 chapter 8.2.3, ANSI C63.10-2013 chapter 6.5

 General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                             regulatory commissions.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                             turntable. By rotating the turntable (range 0° to    position, etc. either on 10m OATS or 3m semi-
                             360°, step 90°) and the EUT itself either on 3-      anechoic room.
                             orthogonal axis (portable equipment) or 2-
                             orthogonal axis (defined operational position of     First a frequency zoom around the critical frequency
                             EUT) the emission spectrum and it’s                  is done to locate the frequency more precisely. After
                             characteristics was recorded with an EMI-            this step, for all identified critical frequencies, the
                             receiver, broadband antenna and software.            maximum peak was determined.

                             Measurement antenna: horizontal and vertical,        Following parameters were varied: the turntable
                             heights: 1,0 m and 1,82 m as worst-case              angle continuously in the range 0 to 360 degree, the
                             determined by an exploratory emission                EUT itself either over 3-orthogonal axis (not
                             measurements. The results are documented in a        defined usage position) or 2-orthogonal axis
                             diagram. Critical frequencies (low margin to         (defined usage position). The measurement antenna
                             limit) are saved within a table for further          height between 1 m and 4 m.
                             investigations. If various operating modes are
                             supported, further investigations are made to find   On the determined worst-case position, a final
                             the worst-case of them. Also the interconnection     measurement with necessary bandwidth and
                             cables and equipment position were varied in         detector according standard has been carried out.
                             order to maximize the emissions.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                       CL = Cable loss
                             M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA = Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 13 of 32

4.4. Test system set-up for radiated electric field measurement above 1 GHz


 Specification:              ANSI C63.4-2014 chapter 8.3, ANSI C63.10-2013 chapter 6.6.3.3 & 6.6.4

 General Description:        Evaluating the emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a CISPR 16-1-4:2010 compliant fully anechoic room (FAR)
                             recognized by the regulatory commission. The measurement distance was set to 3
                             meter for frequencies up to 18 GHz and 2 meter above 18 GHz. A logarithmic
                             periodic antenna is used for the frequency range 30 MHz to 1 GHz. Horn antennas
                             are used for frequency range 1 GHz to 40 GHz. The EUT is aligned within 3 dB
                             beam width of the measurement antenna with three orthogonal axis measurements
                             on the EUT.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 1.55 m height which is placed on the      taining the EUT’s worst-case operation mode,
                             turntable. By rotating the turntable (range 0° to    cable position, etc.
                             360°, step 15°) and the EUT itself either on 3-
                             orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical
                             orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                             EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                             characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                             receiver, broadband antenna and software.            Following parameters were varied: the turntable
                             The measurements are performed in horizontal         angle continuously in the range 0 to 360 degree,
                             and vertical polarization of the measurement         the EUT itself over 3-orthogonal axis and the
                             antennas. The results are documented in a            height for EUT with large dimensions.
                             diagram. Critical frequencies (low margin to
                             limit) are saved within a table for further          On the determined worst-case position, a final
                             investigations. If various operating modes are       measurement with necessary bandwidth and
                             supported, further investigations are made to find   detector according standard has been carried out.
                             the worst-case of them. Also the interconnection     On the determined worst-case position, a final
                             cables and equipment position were varied in         measurement with necessary bandwidth and
                             order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                             M = LT - EC         (2)                   M = Margin
                                                                       LT = Limit
                                                                       AF = Antenna factor
                                                                       CL = Cable loss
                                                                       DF = Distance correction factor (if used)
                                                                       GA = Gain of pre-amplifier (if used)
                             All units are dB-units, positive margin means value is below limit.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 14 of 32


5. Measurements
5.1. Duty-Cycle
5.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
Ambient Climatic conditions               Temperature: (22±2)°C      Rel. humidity: (45±15)%
 test site        441 EMI SAR  348 EMI cond.  443 EMI FAR  347 Radio.lab.               337 OATS      
 equipment        331 HC 4055                                                                         
 spectr. analys.  683 FSU26      120 FSEM         264 FSEK                                            
 power meter  262 NRV-S          266 NRV-Z31  265 NRV-Z33  261 NRV-Z55                  356 NRV-Z1    
 multimeter       341 Fluke 112                                                                       
 DC power         086 LNG50-10  087 EA3013        354 NGPE 40  349 car battery  350 Car battery        463 HP3245A
 line voltage  230 V 50 Hz via public mains        4.35 V DC (fully charged internal battery)
otherwise        K4 Cable                          530 Attenuator 10dB


Method of measurement:               conducted
                                     radiated
A special firmware program is used for test purposes. In opposite to normal operating mode a higher duty-cycle
is set in order to facilitate the measurements. This is maximized at the extent possible.

The necessary duty-cycle correction factor is determined on nominal conditions on middle channel only. It is assumed
that no noticeable changes occur when tested on other channels or climatic conditions. The Duty-Cycle was constant,
means without variations. Minimum and maximum modulation index was tested, the duty cycle is to be found therefore
between a minimum and maximum values.

                                                      DUT Y-CYCLE M e asure me nt

                WLAN            Marker 1            Marker 2
                                                                 T X on        T X off                            Correction-
              Channel 36        [RX ON]            [BTS ON']                                 Converted to
                                                                                                                    Factor:
                                                                                                 DC
                                    ms                  ms          ms            ms                             100log(1/DC)
                                                                                                 (%)
              Modulation                                                                                             (dB)




Results:
Calculated with following formulas:

           Duty cycle:                x
                                               Tx on                                                            1
                                                                          Duty cycle factor [dB]:         10 log 
                                           Tx on  Tx off                                                       x


The results were corrected in order to evaluate for worst-case result each time when average values are necessary for
example average radiated emissions or similar.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 15 of 32

5.2. RF-Parameter - Transmitter Peak output power (conducted and radiated)
5.2.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
 test location      CETECOM Essen (Chapter. 2.2.1)          443 System CTC-FAR-EMI-            Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA  337 OATS                     347 Radio.lab.                    
 receiver           377 ESCS30         001 ESS             489 ESU 40      620 ESU 26                        
otherwise           600 NRVD           357 NRV-Z1          693 TS8997
 spectr. analys.    215 FSU            120 FSEM            264 FSEK                                         
 power supply       456 EA 3013A  457 EA 3013A  459 EA 2032-50  268 EA- 3050                 494 AG6632A  498 NGPE 40
                                              6 dB                Power                               20dB
 otherwise          693 TS8997         248                 529             - cable OTA20     613             K5 Cable
                                              Attenuator          divider                             Attenuator
 line voltage       4.35 V DC (fully charged internal battery)



5.2.2. Reference:
   FCC                                        Part 15 Subpart C, §15.407(a)(1)(2)(3)

   IC                                         RSS-247, Issue 1

   ANSI                                       C63.10-2013
                                              789033 D02 General UNII test procedures v01r03: Subchapter E, Method PM (3)(a)
   KDB Guidance no.
                                              U-NII 1: 5.15-5.25 GHz:
                                             FCC Outdoor access point: 1W + antenna gain max. 6dBi + Elevation > 30° 21 dBm EIRP
                                             FCC Indoor Access Point: 1W + antenna gain max. 6dBi
                                             FCC Mobile & Portable client: 250mW + antenna gain max. 6dBi

                                             IC: E.I.R.P. max. 200mW or 10+10log10(B) whichever power less
                                              U-NII2: 5.25-5.35 GHz:
                                             FCC: 250mW or 11dBm+10log10(B)
                                             IC: 250mW or 11dBm+10log10(B) + EIRP Elevation Mask requirements if max.
   Limits                                        EIRP>200mW
                                                 Max. EIRP 1Watt or 17+10log10(B) whichever power less
                                              U-NII2extension: 5.470-5.725 GHz:
                                             FCC/IC: Lesser of: 250mW or 11dBm+10log10(B) whichever power less
                                                     Max. EIRP 1Watt or 17+10log10(B) whichever power less

                                              U-NII3 : 5.475-5.85 GHz:
                                             FCC/IC: Max. EIRP 1Watt

Remark: --


5.2.3. Antenna characteristics:
According §15.407(a)(1)(2):
 directional gain < 6 dBi (measured: difference between measured conducted and radiated eirp. power)
 directional gain > 6 dBi (measured / applicant’s declaration) -> conducted power reduction necessary
 Maximum declared antenna gain [isotropic]: 5.88 dBi



5.2.4. EUT settings:

The EUT was instructed to send with maximum power (if adjustable) according applicants instructions.
Different modulation characteristics have been checked, e.g. data rates which EUT can operate.
Different frequencies within each operating band have been selected.


5.2.5. Measurement method:

The power was also checked for different data rates, modulation scheme or packet types if applicable.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 16 of 32

5.2.6. Conducted power measurement and EIRP calculation

         Duty-Cycle Correction applicable according. to KDB 789033v01r03

                                             Max. Peak Power (conducted)
                                                        [dBm]
   Set-up no: 2                      U-NII 1               U-NII-A             U-NII2C          U-NII-3
   Op-Mode: 1                    (5150-5250MHz)        (5250-5350MHz)      (5470-5725MHz)   (5725-5825MHz)
        Measured Level
                                         14.46                 13.88           12.13            12.82
              a-Mode
         Measured Level
                                         14.46                 13.74           12.15            12.77
          n(HT20)-Mode
      Measured Max. Level                14.46                 13.88           12.15            12.82
                                   23.98 (Outdoor use 21.0
    Conducted Limit [dBm]:          dBm e.i.r.p. for azimuth
                                            angles
                                                                  23.98           23.98          30.0
                                      > 30° over horizon)
Remark:
   1.) Only maximum values among all data rates and modulations are given above.
       For other data rates please refer measurement table in separate annex A1
   2.) Above values are inclusive Duty cycle correction factors.
       For further details please refer measurement table in separate annex A1
   3.) Conducted Tests performed only on Worst-Case JOYA TOUCH Variant Type: P00AN04HL0GT0W7-GRR
       ( see test report TR2-20842790-15-10b )



5.2.7. Verdict: Pass




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 17 of 32

5.3. RF-Parameter - Power Spectral Density
5.3.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location       CETECOM Essen (Chapter. 2.2.1)          Please see Chapter. 2.2.2          Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA  337 OATS                       347 Radio.lab.                  
 receiver           377 ESCS30         001 ESS             489 ESU           683 FSU26                       
 spectr. analys.    489 ESU            120 FSEM            264 FSEK                                          
 power supply       463 HP3245A  457 EA 3013A  463                           268 EA- 3050    494 AG6632A  498 NGPE 40
                    4.35 V DC (fully charged internal battery)                 060 110 V 60 Hz via PAS 5000
 otherwise         530 10dB Attenuator                                         cable K4

5.3.2. REFERENCES: §15.247(e), RSS-247, Chapter 5.2(2)
(e) For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be
greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be
determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.

5.3.3. TEST CONDITION AND MEASUREMENT TEST SET-UP

Signal ink to test system (if used):       air link      cable connection       none
EUT-grounding                              none          with power supply  additional connection
Equipment set up                           table top                             floor standing
Climatic conditions                       Temperature: (22±3°C)                  Rel. humidity: (40±20)%
General measurement procedures            Please see chapter “Test system set-up for conducted RF-measurement at antenna Port” (W2
                                          Set-up)

5.3.4. EUT SETTINGS:
The EUT was instructed to send with maximum power (if adjustable) according applicants instructions.
Different modulation characteristics have been checked, e.g. data rates which EUT can operate.

5.3.5. MEASUREMENT METHOD/ SPECTRUM-ANALYZER SETTINGS

   Measurement Method                                 ANSI 63.10:2009                 PKPSD-Method
                                                                                       AVGPSD Method
                                                      FCC KDB 789033v01r03
   Center Frequency                                  Nominal channel frequency
   Span                                              5..30% higher than the EBW measured before
   Resolution Bandwidth (RBW)                        > 3 kHz (at least 3 times RBW) - pls. see diagram
   Video Bandwidth (VBW)                             > 10 kHz - pls. see diagram
   Sweep time                                        coupled
   Detector                                          Peak, Max hold mode for method PKPSD or RMS method AVGPSD
   Sweep Mode                                        Repetitive mode, allow trace to stabilize (PKPSD) or single (AVGPSD)
   Addition of correction factors                    external measuring set-up path-loss
Remarks:--




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 18 of 32



5.3.6. RESULTS


                                                     Power Spectral Density

          Test conditions                            Set-up no: 2                                     Op-Mode: 1

            RBW Units                                          dBm/1MHz                                             dBm/500kHz
                                       U-NII 1                    U-NII-A                  U-NII2C                    U-NII-3
         Operating Bands
                                   (5150-5250MHz)             (5250-5350MHz)           (5470-5725MHz)             (5725-5825MHz)
         Channel Number             36        40      48      52     56         64     100    116         140     149     157     165

    Channel Frequency (MHz)        5180       5200   5240    5260   5280    5320       5500   5580        5700    5745    5785    5825

            a-Mode                 3.01       2.21    2.24   2.17   1.33        1.22   0.68   0.86        -0.32   -2.78   -1.78   -1.89
   Measured Conducted (dBm)
        n(HT20)-Mode               2.65       2.68    2.37   1.99   1.95        1.02   0.45   0.43        -0.53   -2.83   -1.90   -2.05
   Measured Conducted (dBm)
     Max. Conducted Value
                                            3.01                    2.17                      0.86                        -1.78
             (dBm)
    Conducted Limits (dBm)                    11                           11                        11                    30

        Antenna Gain (dBi)                  5.88                    5.88                      5.88                        5.88
          Max. E.I.R.P.
                                            8.89                    8.05                      6.74                        4.10
         Calculated(dBm)
                                              11 +
           Limits (dBm)                   Antenna Gain                     17                        17                    30
                                            (< 6 dBi)
Remarks:
   1.) Measurements are performed only for modes with relevant data rates and modulations having maximum
       conducted power values among available a / n(HT20) modes, other data rates and modulations.
       For further details & other data rates please refer diagrams in separate annex A1
   2.) Max. E.I.R.P. Calculated(dBm) = Max. Conducted Value (dBm) + Applicant’s declared Antenna Gain (dBi)
   3.) Conducted Tests performed only on Worst-Case JOYA TOUCH Variant Type: P00AN04HL0GT0W7-GRR
       ( see test report TR2-20842790-15-10b )




5.3.7. VERDICT: Pass




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 19 of 32

5.4. General Limit - Radiated field strength emissions below 30 MHz
5.4.1. Test location and equipment
 test location        CETECOM Essen (Chapter. 2.2.1)          Please see Chapter. 2.2.2               Please see Chapter. 2.2.3
 test site            441 EMI SAR  487 SAR NSA  347 Radio.lab.                                                       
 receiver             377 ESCS30         001 ESS                                                                    
 spectr. analys.      584 FSU            120 FSEM            264 FSEK                                               
 antenna              574 BTA-L          133 EMCO3115  302 BBHA9170  289 CBL 6141                   030 HFH-Z2  477 GPS
 signaling            392 MT8820A  371 CBT32                 547 CMU           594 CMW
 otherwise            400 FTC40x15E  401 FTC40x15E  110 USB LWL  482 Filter Matrix                  378 RadiSense
 DC power             456 EA 3013A  457 EA 3013A  459 EA 2032-50  268 EA- 3050                      494 AG6632A  498 NGPE 40
 line voltage         4.35 V DC (fully charged internal battery)

5.4.2. Requirements
         FCC                 Part 15, Subpart C, §15.205 & §15.209
          IC                 RSS-Gen: Issue 4: §8.9 Table 5
         ANSI                C63.10-2013
      Frequency                         Field strength limit            Distance
                                                                                                             Remarks
        [MHz]                    [μV/m]               [dBμV/m]            [m]
    0.009 – 0.490             2400/f (kHz)     67.6 – 20Log(f) (kHz)        300      Correction factor used due to measurement distance of 3 m
    0.490 – 1.705            24000/f (kHz)     87.6 – 20Log(f) (kHz)        30       Correction factor used due to measurement distance of 3 m
      1.705 – 30                     30                  29.5               30       Correction factor used due to measurement distance of 3 m


5.4.3. Test condition and test set-up
 Signal link to test system (if used):            air link      cable connection        none
 EUT-grounding                                    none          with power supply  additional connection
 Equipment set up                                 table top                              floor standing
 Climatic conditions                             Temperature: (22±3°C)                   Rel. humidity: (40±20)%
                                                  9 – 150 kHz             RBW/VBW = 200 Hz           Scan step = 80 Hz
                           Scan data              150 kHz – 30 MHz RBW/VBW = 9 kHz                   Scan step = 4 kHz
                                                  other:
 EMI-Receiver or Scan-Mode                        6 dB EMI-Receiver Mode  3dB Spectrum analyser Mode
 Analyzer Settings Detector                      Peak (pre-measurement) and Quasi-PK/Average (final if applicable)
                   Mode:                         Repetitive-Scan, max-hold
                   Sweep-Time                    Coupled – calibrated display if continuous signal otherwise adapted to EUT’s individual
                                                 transmission duty-cycle
General measurement procedures                   Please see chapter “Test system set-up radiated magnetic field measurements below 30 MHz”

5.4.4. Measurement Results

The EUT is put on operation on middle channel only. If critical peaks are found (Margin <10 dB) the lowest and
highest channels will be performed too.For more information please see the diagrams.

Table of measurement results:
                     Carrier                                    Set-   OP-
 Diagram                                   Frequency                                                              Used detector
                     Channel                                     up    mode                Remark                                     Result
   No.                                       range
                                                                no.     no.
                   Range       No.                                                                               PK AV       QP

    2.07      Middle            40        9 kHz-30 MHz           1      1           a mode, 6Mbps, Ch40                             Pass


    2.08           High        140        9 kHz-30 MHz           1      1          a mode, 6Mbps, Ch140                             Pass

                                                                                   n(HT20) Mode, MCS0,
    2.10      Middle            40        9 kHz-30 MHz           1      1
                                                                                          Ch40
                                                                                                                                    Pass

                                                                                   n(HT20) Mode, MCS0,
    2.11           Low         100        9 kHz-30 MHz           1      1
                                                                                         Ch100
                                                                                                                                    Pass

                                                                                   n(HT20) Mode, MCS0,
    2.12           Low         149        9 kHz-30 MHz           1      1
                                                                                         Ch149
                                                                                                                                    Pass

Remark: For further details please refer diagrams in separate annex A1




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 20 of 32

5.4.5. Correction factors due to reduced meas. distance (f< 30 MHz)
The used correction factors when the measurement distance is reduced compared to regulatory measurement distance,
are calculated according Extrapolation formulas valid for EUT’s with maximum dimension of 0.625xLambda.
Formula 2+3+4 as presented in ANSI C63.10, Chapter 6.4.4 are used for the calculations of proper extrapolation
factors.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 21 of 32

5.5. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.5.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)           Please see Chapter. 2.2.2      Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA
 receiver           377 ESCS30         001 ESS              489 ESU 40        620 ESU 26
 spectr. analys.    584 FSU            120 FSEM             264 FSEK
 antenna            574 BTA-L          133 EMCO3115  302 BBHA9170  289 CBL 6141           030 HFH-Z2  477 GPS
 signaling          392 MT8820A  371 CBT32                  547 CMU           594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E  110 USB LWL  482 Filter Matrix
 DC power           456 EA 3013A  457 EA 3013A  459 EA 2032-50  268 EA- 3050              494 AG6632A  498 NGPE
 line voltage       4.35 V DC (fully charged internal battery)



5.5.2. Requirements/Limits
                                              Part 15 Subpart B, §15.109, class B
                     FCC
                                              Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                              RSS-Gen., Issue 4, Chapter 8.9, Table 4+6 (licence-exempt radio apparatus)
                                              RSS-Gen., Issue 4, Chapter 7.1.2, Table 2 (receiver)
                         IC
                                              ICES-003, Issue 6, Table 5 (Class B)
                                              RSS-247, Issue 1, Chapter 5
                                              C63.4-2014
                     ANSI
                                              C63.10-2013
                                                                       Radiated emissions limits, 3 meters
                         Frequency [MHz]
                                                         QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                               30 - 88                         100                                         40.0
     Limit
                               88 - 216                        150                                         43.5
                              216 - 960                        200                                         46.0
                              above 960                        500                                         54.0



5.5.3. Restricted bands of operation (FCC §15.205/ RSS-Gen, Issue 4 Chapter 8.9, Table 4)
                   MHz                            MHz                                MHz                                 GHz
  0.090-0.110                      16.42-16.423                         399.9-410                          4.5-5.15
  0.495-0.505                      16.69475-16.69525                    608-614                            5.35-5.46
  2.1735-2.1905                    16.80425-16.80475                    960-1240                           7.25-7.75
  4.125-4.128                      25.5-25.67                           1300-1427                          8.025-8.5
  4.20725-4.20775                  37.5-38.25                           1645.5-1646.5                      9.3-9.5
  6.215-6.218                      73-74.6                              1660-1710                          10.6-12.7
  6.26775-6.26825                  74.8-75.2                            1718.8-1722.2                      13.25-13.4
  6.31175-6.31225                  108-121.94                           2200-2300                          14.47-14.5
  8.291-8.294                      123-138                              2310-2390                          15.35-16.2
  8.362-8.366                      149.9-150.05                         2483.5-2500                        17.7-21.4
  8.37625-8.38675                  156.52475-156.52525                  2690-2900                          22.01-23.12
  8.41425-8.41475                  156.7-156.9                          3260-3267                          23.6-24.0
  12.29-12.293                     162.0125-167.17                      3332-3339                          31.2-31.8
  12.51975-12.52025                167.72-173.2                         3345.8-3358                        36.43-36.5
  12.57675-12.57725                240-285                              3600-4400                          --
  13.36-13.41                      322-335.4                            --                                 --
  Remark: only spurious emissions are allowed within these frequency bands not exceeding the limits per §15.209




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 22 of 32

5.5.4. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
 General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”



5.5.5. MEASUREMENT RESULTS

The results are presented below in summary form only. For more information please consult the diagrams included in
annex 1.

Table of measurement results:

  Dia-     Carrier Channel                          Set-      OP-                                            Used detector         Result
                                  Frequency
  gram                                               up       mode                  Remark
                                    range
   no.                                              no.        no.
            Range        No.                                                                                PK     AV     QP
                                  30 MHz –
  3.07     Middle        40                           1          1          a mode, 6Mbps, Ch40                                  Pass
                                   1 GHz
                                  30 MHz –
  3.08      High        140                           1          1          a mode, 6Mbps, Ch140                                 Pass
                                   1 GHz
                                  30 MHz –                                  n(HT20) Mode, MCS0,
  3.10     Middle        40                           1          1                                                               Pass
                                   1 GHz                                           Ch40
                                  30 MHz –                                  n(HT20) Mode, MCS0,
  3.11      Low         100                           1          1                                                      s        Pass
                                   1 GHz                                          Ch100
                                  30 MHz –                                  n(HT20) Mode, MCS0,
  3.12      Low         149                           1          1                                                      s        Pass
                                   1 GHz                                          Ch149
Remark: For further details please refer diagrams in separate annex A1




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 23 of 32

5.6. General Limit - Radiated emissions, above 1 GHz
5.6.1. Test location and equipment FAR
 test site          441 EMI SAR  348 EMI cond.  443             EMI FAR      347     Radio.lab.  337 OATS          
 spectr. analys.    584 FSU          120 FSEM             264   FSEK         489     ESU 40                        
 antenna meas       574 BTA-L        289 CBL 6141  608          HL 562       549     HL025       302 BBHA9170       477 GPS
 antenna meas       123 HUF-Z2       132 HUF-Z3           030   HFH-Z2       376     BBHA9120E                      
 antenna subst      071 HUF-Z2       020 EMCO3115  063          LP 3146      303     BBHA9170                      
 multimeter         341 Fluke 112                                                                                  
 signaling          392 MT8820A  371 CBT32                547   CMU          594     CMW
 DCpower            086 LNG50-10  087 EA3013              354   NGPE 40      349     car battery 350 Car battery   
 line voltage       4.35 V DC (fully charged internal battery)



5.6.2. Requirements/Limits (CLASS B equipment)
                            Part 15 Subpart B, §15.109 class B
          FCC               Part 15 Subpart C, §15.209 for frequencies defined in §15.205
                            Part 15 Subpart C, §15.407(b)(1)(2)(3) 9

                            RSS-Gen., Issue 4, Chapter 8.9, Table 4+6 (transmitter licence excempt)
                            RSS-Gen., Issue 4, Chapter 8.9, Table 2 (receiver)
           IC
                            ICES-003, Issue 6, Chapter 6.2.2, Table 7 (class B)
                            RSS-247, Issue 1, Chapter 6

                            C63.4-2014
         ANSI
                            C63.10-2013
                                                                                Limits
       Frequency                       AV                             AV                          Peak                      Peak
         [MHz]                       [µV/m]                        [dBµV/m]                      [µV/m]                  [dBµV/m] or
                                                                                                                         [dBm/MHz]
      above 1 GHz
   for frequencies as
       defined in
         §15.205                         500                         54.0                         5000                   74.0 dBµV/m
           or
    RSS-Gen., Issue
   4, §8.10 - Table 6
                                                                                                                         -27dBm/MHz
     §15.407(b)                                                                                                         (68.5 dBµV/m)
         Or                              --                           --                            --                         or
   RSS-247, Issue 1                                                                                                      -17dBm/MHz
                                                                                                                        (78.5 dBµV/m)



5.6.3. Test condition and measurement test set-up
 Signal link to test system (if used):          air link      cable connection       none
 EUT-grounding                                  none          with power supply  additional connection
 Equipment set up                               table top 1.5m height                 floor standing
 Climatic conditions                           Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan frequency range:                 1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer      Scan-Mode                         6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                         Peak and Average
              RBW/VBW                          1 MHz / 3 MHz
              Mode:                            Repetitive-Scan, max-hold
              Scan step                        400 kHz
              Sweep-Time                       Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
General measurement procedures                 Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 24 of 32

5.6.4. Measurement Results

The results are presented below in summary form only. For more information please consult the diagrams included in
annex 1.


   Dia-     Carrier Channel               Set-   OP-                                  Used detector    Result
                              Frequency
   gram                                    up    mode             Remark
                                range
    no.                                   no.     no.
            Range     No.                                                            PK    AV    QP

   4.07    Middle      40      1-7GHz      1       1        a mode, 6Mbps, Ch40                     Pass

  4.07a    Middle      40     7-18GHz      1       1        a mode, 6Mbps, Ch40                     Pass


  4.07b    Middle      40     18-40GHz     1       1        a mode, 6Mbps, Ch40                     Pass


   4.08     High      140      1-7GHz      1       1       a mode, 6Mbps, Ch140                     Pass


  4.08a     High      140     7-18GHz      1       1       a mode, 6Mbps, Ch140                     Pass


  4.08b     High      140     18-40GHz     1       1       a mode, 6Mbps, Ch140                     Pass

                                                           n(HT20) Mode, MCS0,
   4.10    Middle      40      1-7GHz      1       1                                                Pass
                                                                   Ch40
                                                           n(HT20) Mode, MCS0,
  4.10a    Middle      40     7-18GHz      1       1                                                Pass
                                                                   Ch40
                                                           n(HT20) Mode, MCS0,
  4.10b    Middle      40     18-40GHz     1       1                                                Pass
                                                                   Ch40
                                                           n(HT20) Mode, MCS0,
   4.11      Low      100      1-7GHz      1       1                                                Pass
                                                                  Ch100
                                                           n(HT20) Mode, MCS0,
  4.11a      Low      100     7-18GHz      1       1                                                Pass
                                                                  Ch100
                                                           n(HT20) Mode, MCS0,
  4.11b      Low      100     18-40GHz     1       1                                                Pass
                                                                  Ch100
                                                           n(HT20) Mode, MCS0,
   4.12      Low      149      1-7GHz      1       1                                                Pass
                                                                  Ch149
                                                           n(HT20) Mode, MCS0,
  4.12a      Low      149     7-18GHz      1       1                                                Pass
                                                                  Ch149
                                                           n(HT20) Mode, MCS0,
  4.12b      Low      149     18-40GHz     1       1                                                Pass
                                                                  Ch149
Remark: 1.) For further details please refer diagrams in separate annex A1
      2.)As no critical harmonics within 6 dB margin from limits have been observed;
      hence measurements from 18 GHz-40 GHz have been not tested.




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 25 of 32

5.7. General Limit - Band-edge compliance measurements
5.7.1. Test location and equipment FAR
 test site          441 EMI SAR  348 EMI cond.  443             EMI FAR      347   Radio.lab.   337 OATS           
 spectr. analys.    584 FSU          120 FSEM             264   FSEK         489   ESU 40                          
 antenna meas       574 BTA-L        289 CBL 6141  608          HL 562       549   HL025        302 BBHA9170        477 GPS
 antenna meas       123 HUF-Z2       132 HUF-Z3           030   HFH-Z2                                             
 antenna subst      071 HUF-Z2       020 EMCO3115  063          LP 3146      303   BBHA9170                        
 multimeter         341 Fluke 112                                                                                  
 signaling          392 MT8820A  371 CBT32                547   CMU          594   CMW
 DC power           086 LNG50-10  087 EA3013              354   NGPE 40      349   car battery  350 Car battery    
 line voltage       4.35 V DC (fully charged internal battery)



5.7.2. Test condition and measurement test set-up
 Signal ink to test system (if used):         air link      cable connection      none
 EUT-grounding                                none          with power supply  additional connection
 Equipment set up                             table top 1.5m height                floor standing
 Climatic conditions                         Temperature: (22±3°C)                 Rel. humidity: (40±20)%
Spectrum- Scan frequency range:               1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other: see diagrams
Analyzer      Scan-Mode                       6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                       Peak and Average
              RBW/VBW                        Band-edge: 1 MHz / 3 MHz
                                             Repetitive-Scan, max-hold
           Mode:                             40kHz or 400 kHz
           Scan step                         Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
           Sweep-Time
General measurement procedures               Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”
                                             for general measurements procedures in anechoic chamber.



5.7.3. Requirements/ Limits
                                                 Part 15 Subpart C, §15.407(b)(1)(2)(3)
   FCC
                                                 Part 15 subpart C, §15.209 @ frequencies defined in §15.205
                                                 RSS-247, Issue 1, Chapter 5.5; RSS-Gen: Issue 4: §8.9 Table 4+5+6
   IC
                                                 RSS-Gen: Issue 4: §8.9, Table 4+6
                                                 C63.10-2009 for TX-mode
   ANSI
                                                 C63.10-2013, Chapter 6.10.6
   KDB Guidance no.                              789033 D01 General UNII test procedures v01r03’: G(2)(c)(d), G(3)(d)
   Limits                                                             AV                                             Peak
   accord.         Above 1GHz                                      [dBµV/m]                                       [dBµV/m]
   §15.205                                                            54.0                                            74.0
                                                                       EIRP – limit for outside operating frequency band
                   Carrier operating
                                                               Peak [dBm]                                     Peak [dBµV/m]1.)
                   frequency band [MHz]
                                                            30 MHz to 40 GHz                               30 MHz to 40 GHz@3m
                   5.15 – 5.25 GHz                                   -27.0                                           68.2
   Limits          5.25 – 5.35 GHz                                   -27.0                                           68.2
   accord.         5.47 – 5.725 GHz                                  -27.0                                           68.2
   §15.407
                                                                  -27.0                                              68.2
                                                 (10 MHz greater above/below band edge)             (10 MHz greater above/below band edge)
                   5.725 – 5.825 GHz
                                                                  -17.0                                              78.2
                                                   (within 10 MHz offset to band-edge)                (within 10 MHz offset to band-edge)

Remark: 1.) Conversion formula between EIRP and field strength used (Please read measurement method).

5.7.4. Measurement method

For uncritical results where a measurement bandwidth of 1MHz can clearly show the compliance without influencing
the results, a field strength measurement was performed only.

For critical results a Marker-Delta marker method was used for showing compliance to restricted bands according
§15.205. The method is according ANSI 63.10:2013 “Marker-Delta method”, §6.9.3. The method consists of three
independent steps:
    1. Step: Prior to the measurement the fundamental radiated In-Band field strength was performed. The determined
         value is used as reference value.



TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 26 of 32

    2.      Step: Second step consist of finding the relative attenuation between the fundamental emission and the
            maximum local out-of-band emission (within 2 MHz range around the band edge either on the band-edge
            directly or some modulation product if the level is greater than that on the band-edge) when measured with
            lower resolution bandwidth.
    3.      Step: The delta value recorded in step 2 will be subtracted from value recorded in step 1, thus giving the
            required field strength at the band-edge. This value must fulfil the requirements for radiated spurious emissions
            in restricted bands in §15.205 with the general limits of §15.209.

The formula EIRP[dBm] = E [dBµV/m] - 95.2 for radiated measurements, which used field strength at 3 meters to
convert the value in dBm.

5.7.5. EUT settings
The EUT was instructed to send with maximum intended power levels according to applicants instructions.

5.7.6. Results:

5.7.6.1. Non-restricted bands near-by - limits according FCC §15.407 and RSS-247, Issue 1, Chapter 5.5

                                                     Fundamental Value
  Diagram       Channel        Restricted                [dBuV/m]              Peak-Value at Band-     Limit      Margin
                                                                                                                                 Verdict              Remark:
    No.           No.           band ?                             Average-      Edge [dBuV/m]       [dBuV/m]      [dB]
                                                 Peak-Value
                                                                    Value
                                                                                                                                                   a mode, 6 Mbps,
   9.15          100              No                104.94         97.6              55.70             68.2       12.5           Pass                  CH100

                                                                                                                                             n(HT20) mode, MCS0,
   9.19          100              No                106.10         97.21             57.20             68.2       11.0           Pass               CH100

                                                                                                                                                   a mode, 6 Mbps,
   9.16          140              No                104.80         97.74             59.80             68.2       8.40           Pass                  CH140

                                                                                                                                             n(HT20) mode, MCS0,
   9.20          140              No                106.13         96.9              59.66             68.2       8.54           Pass               CH140

                                                                                                                                             n(HT20) mode, MCS0,
   9.21          149              No                105.86         96.71             65.26             78.2      12.94           Pass               CH149

                                                                                                                                             n(HT20) mode, MCS0,
   9.22          165              No                106.81         97.96             62.76             78.2      15.44           Pass               CH165




5.7.6.2. Restricted bands near-by
(§15.205 with limits accord. FCC §15.209) and (RSS-Gen, Issue 4, Chapter 8.10)

                                            Fundamental Value         Value of Band-Edge          Limits                Margin
 Diagram     Channel      Restricted            [dBuV/m]                  [dBuV/m]              [dBuV/m]                 [dB]           Verdict:         Remark:
   No.         No.         band ?           Peak-       Average-       Peak-     Average-    Peak-   Average-   Peak-       Average-
                                            Value        Value         Value      Value      Value    Value     Value        Value
                                                                                                                                                        a mode, 6
  9.13         36           Yes         105.14          98.00         54.60      44.60       74        54       19.40        9.40          Pass        Mbps, CH36
                                                                                                                                                         n(HT20)
  9.17         36           Yes         107.69          98.63         57.21      45.90       74        54       16.79        8.10          Pass        mode, MCS0,
                                                                                                                                                          CH36
                                                                                                                                                        a mode, 6
  9.14         64           Yes         104.59           97.5           54       44.76       74        54        20          9.24          Pass        Mbps, CH64
                                                                                                                                                         n(HT20)
  9.18         64           Yes         106.28          97.38         53.96      44.71       74        54       20.04        9.29          Pass        mode, MCS0,
                                                                                                                                                          CH64
Remark: Please refer chapter 5.1 for applicable duty-cycle correction factor




5.7.7. Verdict: Pass




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 27 of 32

 5.8. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate coverage
factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and it’s
contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
      RF-Measurement          Reference         Frequency range                                                  Remarks
                                                                           confidence level of 95%
  Conducted emissions                    9 kHz - 150 kHz           4.0 dB
                            CISPR 16-2-1                                                                             -
  (U CISPR)                              150 kHz - 30 MHz          3.6 dB
  Radiated emissions                     30 MHz - 1 GHz            4.2 dB
                            CISPR 16-2-3                                                                          E-Field
  Enclosure                              1 GHz - 18 GHz            5.1 dB
  Disturbance power         CISPR 16-2-2 30 MHz - 300 MHz          -                                                 -
                                                                                                                Substitution
  Power Output radiated            -          30 MHz - 4 GHz       3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                              Set-up No.                        BT1 W1          W2         --
                                                                    C1     C2
  Power Output conducted           -          9 kHz - 12.75 GHz    N/A 0.60 0.7 0.25            N/A        --        -
                                              12.75 - 26.5GHz      N/A 0.82      --   N/A       N/A        --
  Conducted emissions              -          9 kHz - 2.8 GHz      0.70 N/A 0.70 N/A            0.69       --    N/A - not
  on RF-port                                  2.8 GHz - 12.75GHz   1.48 N/A 1.51 N/A            1.43       --    applicable
                                              12.75 GHz - 18GHz    1.81 N/A 1.83 N/A            1.77       --
                                              18 GHz - 26.5GHz     1.83 N/A 1.85 N/A            1.79       --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
  Occupied bandwidth               -          9 kHz - 4 GHz                                                     error
                                                                   1.0 dB                                       Power
                                   -                               0.1272 ppm (Delta Marker)                    Frequency
  Emission bandwidth                          9 kHz - 4 GHz                                                     error
                                   -                               See above: 0.70 dB                           Power
  Frequency stability              -          9 kHz - 20 GHz       0.0636 ppm                                         -
                                              150 kHz - 30 MHz     5.0 dB                                       Magnetic
  Radiated emissions                          30 MHz - 1 GHz       4.2 dB                                       field
                                   -
  Enclosure                                   1 GHz - 20 GHz       3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 28 of 32


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                              FCC, Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
      MRA US-EU                                                                               Commission
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)
          0003                                                                                Laboratory Division, USA
 348                 Mains Ports Conducted Interference Measurements
                                                                                              (MRA US-EU 0003)
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-1967      Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 29 of 32


8. Instruments and Ancillary
8.1. Used equipment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory equipment.


8.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


 001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
 012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
 013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
 017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
 053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
 119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
 140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
 261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
 262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
 263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
 295         Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
 298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
 323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
 335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
 340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
 355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
 365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
 366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
 371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
 377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
 378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
 389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
 392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
 436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
 441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
 442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
 443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
 444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
 460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
 489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
 491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
 524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
 526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
 527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
 528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
 546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
 547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
 584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
 597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
 598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
 620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
 642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
 670         Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
 689         Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
 692         Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 30 of 32



8.1.2. Single instruments and test systems
  Ref.-No.




                                                                                                                          calibration
                                                                                                                          Interval of



                                                                                                                                            Remark
                            Equipment                           Type                Serial-No.        Manufacturer                                       Cal
                                                                                                                                                         due

 001         EMI Test Receiver                         ESS                     825132/017        Rohde & Schwarz          12 M          -            30.05.2017
 005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005        Rohde & Schwarz          12 M          -            30.05.2017
 007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002        Rohde & Schwarz          12 M          -            30.05.2017
 009         Power Meter (EMS-radiated)                NRV                     863056/017        Rohde & Schwarz          24 M          -            30.04.2017
 016         Line Impedance Simulating Network         Op. 24-D                B6366             Spitzenberger+Spies      36 M          -            30.05.2019
 020         Horn Antenna 18 GHz (Subst 1)             3115                    9107-3699         EMCO                     36/12 M       -            31.03.2017
 021         Loop Antenna (H-Field)                    6502                    9206-2770         EMCO                     36 M          -            30.04.2018
 030         Loop Antenna (H-field)                    HFH-Z2                  879604/026        Rohde & Schwarz          36 M          -            30.04.2018
 033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18         Rohde & Schwarz          24 M          -            30.04.2017
 057         relay-switch-unit (EMS system)            RSU                     494440/002        Rohde & Schwarz          pre-m         1a
 060         power amplifier (DC-2kHz)                 PAS 5000                B6363             Spitzenberger+Spies      -             3
                                                       WRCT 1900/2200-5/40-
 066         notch filter (WCDMA; FDD1)                                        5                 Wainwright GmbH          12 M          1g           30.06.2016
                                                       10EEK
 086         DC - power supply, 0 -10 A                LNG 50-10               -                 Heinzinger Electronic    pre-m         2
 087         DC - power supply, 0 -5 A                 EA-3013 S               -                 Elektro Automatik        pre-m         2
 091         USB-LWL-Converter                         OLS-1                   007/2006          Ing. Büro Scheiba        -             4
 099         passive voltage probe                     ESH2-Z3                 299.7810.52       Rohde & Schwarz          36 M          -            30.04.2018
 100         passive voltage probe                     Probe TK 9416           without           Schwarzbeck              36 M          -            30.04.2018
 110         USB-LWL-Converter                         OLS-1                   -                 Ing. Büro Scheiba        -             4
 119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547            BOCONSULT                36 M          -            30.05.2019
 136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697         EMCO                     36 M          -            30.04.2018
 140         Signal Generator                          SMHU                    831314/006        Rohde & Schwarz          24 M          -            30.05.2018
 248         attenuator                                SMA 6dB 2W              -                 Radiall                  pre-m         2
 249         attenuator                                SMA 10dB 10W            -                 Radiall                  pre-m         2
 252         attenuator                                N 6dB 12W               -                 Radiall                  pre-m         2
 256         attenuator                                SMA 3dB 2W              -                 Radiall                  pre-m         2
 257         hybrid                                    4031C                   04491             Narda                    pre-m         2
 260         hybrid coupler                            4032C                   11342             Narda                    pre-m         2
 261         Thermal Power Sensor                      NRV-Z55                 825083/0008       Rohde & Schwarz          24 M          -            30.05.2018
 262         Power Meter                               NRV-S                   825770/0010       Rohde & Schwarz          24 M          -            30.05.2018
 263         Signal Generator                          SMP 04                  826190/0007       Rohde & Schwarz          36 M          -            30.05.2019
 265         peak power sensor                         NRV-Z33, Model 04       840414/009        Rohde & Schwarz          24 M          -            30.05.2018
 266         Peak Power Sensor                         NRV-Z31, Model 04       843383/016        Rohde & Schwarz          24 M          -            30.05.2018
 267         notch filter GSM 850                      WRCA 800/960-6EEK       9                 Wainwright GmbH          pre-m         2
 270         termination                               1418 N                  BB6935            Weinschel                pre-m         2
 271         termination                               1418 N                  BE6384            Weinschel                pre-m         2
 272         attenuator (20 dB) 50 W                   Model 47                BF6239            Weinschel                pre-m         2
 273         attenuator (10 dB) 100 W                  Model 48                BF9229            Weinschel                pre-m         2
 274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321            Weinschel                pre-m         2
 275         DC-Block                                  Model 7003 (N)          C5129             Weinschel                pre-m         2
 276         DC-Block                                  Model 7006 (SMA)        C7061             Weinschel                pre-m         2
 279         power divider                             1515 (SMA)              LH855             Weinschel                pre-m         2
 287         pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P    379418            Miteq                    12 M          1c           30.06.2017
 291         high pass filter GSM 850/900              WHJ 2200-4EE            14                Wainwright GmbH          12 M          1c           30.06.2017
 298         Univ. Radio Communication Tester          CMU 200                 832221/091        Rohde & Schwarz          pre-m         3
 300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020       Rohde & Schwarz          12 M          -            30.05.2017
 301         attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272            Lucas Weinschel          pre-m         2
 302         horn antenna 40 GHz (Meas 1)              BBHA9170                155               Schwarzbeck              36 M          -            31.03.2017
 303         horn antenna 40 GHz (Subst 1)             BBHA9170                156               Schwarzbeck              36 M          -            31.03.2017
 331         Climatic Test Chamber -40/+80 Grad        HC 4055                 43146             Heraeus Vötsch           Pre-m         2
 341         Digital Multimeter                        Fluke 112               81650455          Fluke                    24 M          -            30.05.2018
 342         Digital Multimeter                        Voltcraft M-4660A       IB 255466         Voltcraft                24 M          -            30.04.2017
 347         laboratory site                           radio lab.              -                 -                        -             5
 348         laboratory site                           EMI conducted           -                 -                        -             5
 354         DC - Power Supply 40A                     NGPE 40/40              448               Rohde & Schwarz          pre-m         2
 355         Power Meter                               URV 5                   891310/027        Rohde & Schwarz          24 M          -            30.05.2018
 357         power sensor                              NRV-Z1                  861761/002        Rohde & Schwarz          24 M          -            30.04.2017
 371         Bluetooth Tester                          CBT32                   100153            R&S                      36 M          -            30.05.2019
 373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535            Rohde & Schwarz          12 M          -            30.05.2017
 377         EMI Test Receiver                         ESCS 30                 100160            Rohde & Schwarz          12 M          -            30.05.2017
 389         Digital Multimeter                        Keithley 2000           0583926           Keithley                 24 M          -            30.04.2017
 392         Radio Communication Tester                MT8820A                 6K00000788        Anritsu                  12 M          -            30.05.2017
 431         Model 7405                                Near-Field Probe Set    9305-2457         EMCO                     -             4
 436         Univ. Radio Communication Tester          CMU 200                 103083            Rohde & Schwarz          12 M          -            30.04.2017
 439         UltraLog-Antenna                          HL 562                  100248            Rohde & Schwarz          36 M          -            31.03.2017
                                                       System CTC-FAR-EMI-                       ETS-Lindgren /
 443         CTC-FAR-EMI-RSE                                                   -                                          12 M          5            30.06.2017
                                                       RSE                                       CETECOM
                                                       WRCT 1850.0/2170.0-                       Wainwright Instruments
 448         notch filter WCDMA_FDD II                                         5                                          12 M          1c           30.06.2017
                                                       5/40-                                     GmbH


TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 31 of 32
  Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                              Equipment                           Type                     Serial-No.              Manufacturer                                   Cal
                                                                                                                                                                  due

                                                       WRCT 824.0/894.0-5/40-
 449         notch filter WCDMA FDD V                                              1                       Wainwright              12 M          1c           30.06.2017
                                                       8SSK
 454         Oscilloscope                              HM 205-3                    9210 P 29661            Hameg                   -             4
 456         DC-Power supply 0-5 A                     EA 3013 S                   207810                  Elektro Automatik       pre-m         2
 459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50               910722                  Elektro Automatik       pre-m         2
 460         Univ. Radio Communication Tester          CMU 200                     108901                  Rohde & Schwarz         12 M          -            30.04.2017
 463         Universal source                          HP3245A                     2831A03472              Agilent                 -             4
 466         Digital Multimeter                        Fluke 112                   89210157                Fluke USA               24 M          -            30.05.2018
 467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA               36 M          -            30.04.2018
 468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA               36 M          -            30.04.2018
 477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink   -             3
 480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz         24 M          -            30.04.2017
 482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)           -             1d
                                                       AMF-5D-02501800-25-
 484         pre-amplifier 2,5 - 18 GHz                                            1244554                 Miteq                   12 M          -            30.06.2017
                                                       10P
                                                       System EMI field (SAR)                              ETS Lindgren /
 487         System CTC NSA-Verification SAR-EMI                                   -                                               24 M          -            31.07.2017
                                                       NSA                                                 CETECOM
 489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz         12 M          -            30.05.2017
                                                       WRCG 1709/1786-
 502         band reject filter                                                    SN 9                    Wainwright              pre-m         2
                                                       1699/1796-
 503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright              pre-m         2
                                                       WRCA 800/960-02/40-
 512         notch filter GSM 850                                                  SN 24                   Wainwrght               12 M          1c           30.06.2017
                                                       6EEK
 517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                pre-m         2
 523         Digital Multimeter                        L4411A                      MY46000154              Agilent                 24 M          -            30.04.2017
 529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel               pre-m         2
 530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                       pre-m         2
 546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                     12 M          -            30.05.2017
 547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz         12 M          -            30.04.2017
 549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz         36/12 M       -            31.07.2018
             System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
 550                                                                               -                                               24 M          -            31.07.2017
             EMI                                       VSWR                                                Lindgren/CETECOM
 552         high pass filter 2,8-18GHz                WHKX 2.8/18G-10SS           4                       Wainwright              12 M          1c           30.06.2017
 557         System CTC-OTA-2                          R&S TS8991                  -                       Rohde & Schwarz         12 M          5            30.09.2016
                                                       System CTC FAR S-
 558         System CTC FAR S-VSWR                                                 -                       CTC                     24 M          -            19.04.2017
                                                       VSWR
 574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia               36/12 M       -            31.03.2019
 584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz         pre-m         -
 594         Wideband Radio Communication Tester       CMW 500                     101757                  Rohde & Schwarz         12 M          -            30.04.2017
 597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz         pre-m         -
 598         Spectrum Analyzer                         FSEM 30 (Reserve)           831259/013              Rohde & Schwarz         24 M          -            30.04.2017
 600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz         24 M          -            30.04.2017
 601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz         24 M          -            30.04.2017
 602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz         24 M          -
 611         DC power supply                           E3632A                      KR 75305854             Agilent                 pre-m         2
 612         DC power supply                           E3632A                      MY 40001321             Agilent                 pre-m         2
 613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                 pre-m         2
 616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                   24 M          -            30.05.2018
 617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits           -             2
 618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA      -             2
 619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA     -             3
 620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz           12 M          -            30.05.2017
 621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz         pre-m         2
 625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                 -             2
                                                                                   201.0999.9302.6.4.1.4
 627         data logger                               OPUS 1                                              G. Lufft GmbH           24 M          -            30.04.2017
                                                                                   3
 634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz         pre-m         2
                                                       HDMI cable with Ethernet
 637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                -             2
                                                       1m
 638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                -             2
 640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                -             2
 641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                -             2
 644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits           -             -
 670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz         24 M          -            30.05.2018
 671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik       pre-m         2
 678         Power Meter                               NRP                         101638                  Rohde&Schwarz           pre-m         -
 683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz         12 M          -            30.05.2017
                                                                                                           Narda Safety Test
 686         Field Analyzer                            EHP-200A                    160WX30702                                      24 M          -            30.04.2017
                                                                                                           Solutions
 687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz           12 M          -            30.05.2017
 688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                   pre-m         -
 690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz           12 M          -            30.05.2017
 692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz         36 M          -            31.03.2017


TR2-20842790-15-8b


Test Report 2-20842790-15-8b, Page 32 of 32
  Ref.-No.




                                                                                                                                          calibration
                                                                                                                                          Interval of



                                                                                                                                                            Remark
                              Equipment                            Type                    Serial-No.              Manufacturer                                      Cal
                                                                                                                                                                     due

 697         Power Splitter                             ZN4PD-642W-S+                165001445                Mini-Circuits               -             2




             8.1.3. Legend


 Note / remarks                              Calibrated during system calibration:
                                   1a        System CTC-SAR-EMS (Ref.-No. 442)
                                   1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                                   1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                   1d        System CTC-SAR-EMI (Ref.-No . 441)
                                   1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                   1f        System CTC-CTIA-OTA (Ref.-No . 420)
                                   1g        System CTC-FAR-EMS (Ref.-No . 444)
                                   2         Calibration or equipment check immediately before measurement
                                   3         Regulatory maintained equipment for functional check or support purpose
                                   4         calibration of this equipment
                                             Ancillary equipment   without has no effect
                                                                           calibration   onmechanical
                                                                                       e.g. measuring result
                                                                                                      equipment or monitoring equipment
                                   5         Test System


 Interval of calibration           12 M      12 month
                                   24 M      24 month
                                   36 M      36 month
                                   24/12 M   Calibration every 24 months, between this every 12 months internal validation
                                   36/12 M   Calibration every 36 months, between this every 12 months internal validation
                                   Pre-m     Check before starting the measurement
                                   -         Without calibration




9. Versions of test reports (change history)

              Version             Applied changes                                                                                                Date of release
                --                Initial release                                                                                                 2016-10-12
                --                --                                                                                                                   --




TR2-20842790-15-8b



Document Created: 2016-10-31 11:33:48
Document Modified: 2016-10-31 11:33:48

© 2024 FCC.report