test report_15.207_rss gen conducted emissions ac power

FCC ID: U4GJNGW

Test Report

Download: PDF
FCCID_3211617

                                      PARTIAL T E S T R E P O R T
                                        No.: 2-20842790-15-10d

                                                           According to:
                                                         FCC Regulations
                                                      Subpart 15C, Part 15.207

                                                           IC-Regulations
                                                          RSS-Gen, Issue 4




                                                                 for

                                                Datalogic ADC S.r.l.
                        JOYA TOUCH: P00AN04HL0HT0W7-GR0
                      JOYA TOUCH Type : P00AN04HL0GT0W7-GRR
                        JOYA TOUCH: P00AN04HL0GT0W7-GRR
                                                  FCC-ID: U4GJNGWB
                                                   IC: 3862E-JNGWB
                                                  PMN: JOYA TOUCH
                                              HVIN: JNG P HH / JNG P GUN

                                            Laboratory Accreditation and Listings




                                                                                                     Voluntary Controls for
                                                                              Industry Canada     Electromagnetic Emissions
                                                                                                          Reg. No.:
                                                       MRA US-EU 0003        Reg. No.: 3462D-2         R-2666 C-2914,
                                                                             Reg. No.: 3462D-3         T-1967, G-301




                                      accredited according to DIN EN ISO/IEC 17025
                                                    CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                       Page 1 of 17
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 2-20842790-15-10d, Page 2 of 17


Table of contents
1. SUMMARY OF TEST RESULTS................................................................................................................... 3
  1.1. TEST OVERVIEW ACCORDING FCC PART 15B AND CANADIAN RSS- OR ICES STANDARDS . 3
2. ADMINISTRATIVE DATA ............................................................................................................................ 4
  2.1. Identification of the testing laboratory .......................................................................................................... 4
  2.2. Test location ................................................................................................................................................. 4
  2.3. Organizational items ..................................................................................................................................... 4
  2.4. Applicant’s details ........................................................................................................................................ 4
  2.5. Manufacturer’s details .................................................................................................................................. 4
3. EQUIPMENT UNDER TEST (EUT) .............................................................................................................. 5
  3.1. EUT: Type, S/N etc. and short descriptions used in this test report ............................................................. 5
  3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ............................................................... 5
  3.3. EUT set-ups .................................................................................................................................................. 5
  3.4. EUT operating modes ................................................................................................................................... 6
  3.5. Additional declaration and description of AE1............................................................................................. 6
  3.6. Configuration of cables used for testing ....................................................................................................... 7
4. DESCRIPTION OF TEST SYSTEM SET-UP’S ........................................................................................... 8
  4.1. Test system set-up for AC power-line conducted emission measurements .................................................. 8
5. MEASUREMENTS .......................................................................................................................................... 9
  5.1. General Limit - Conducted emissions on AC-Power lines ...................................................................... 9
6. MEASUREMENT UNCERTAINTIES......................................................................................................... 10
7. ABBREVIATIONS USED IN THIS REPORT ............................................................................................ 11
8. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES .................... 11
9. INSTRUMENTS AND ANCILLARY ........................................................................................................... 12
  9.1. Used equiment “CTC” ................................................................................................................................ 12
10. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ...................................................................... 15
11. MEASUREMENT DIAGRAMS .................................................................................................................. 16



Table of annex                        The listed attachments are an integral part of this report                                                Total pages
Annex 1: External photographs of EUT (separate document TR2-20842790-15-10d-Annex1)                                                                                   9
Annex 2: Internal photographs of EUT (separate document)                                                                                                        none
Annex 3: Test set-up photographs (separate document TR2-20842790-15-10d-Annex 3)                                                                                      3

The listed attachments are an integral part of this report.




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 3 of 17



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.


The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveilance tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a digital device with support of
radiofrequency technologies. A typical operating mode was tested according intended use of the equipment.

Following tests have been performed to show compliance with applicable FCC Part 15, Subpart C (Intentional
Radiators) of the CFR 47 Rules, Edition 4th November 2015 and Canadian RSS-Gen, Issue 4 standard.

1.1. TEST OVERVIEW ACCORDING FCC PART 15B AND CANADIAN RSS- OR
ICES STANDARDS
   No. of                                                                     References, Standards & Limits                                 EUT
                             Test                                                                                               EUT
  Diagram                                                       Port                                                                          op-              Result
                             Cases                                      FCC              IC              Limits                set-up
   group                                                                                                                                     mode
                           AC
                        Power Lines
                                                                                  RSS-Gen, Issue 4
                                                          AC                                            Class A
        1                                                              §15.207      Chapter 8.8 ,                                 1              1               Pass
                        Conducted                      Power lines                                      Class B
                                                                                      Table 3
                         emissions
                      0.15 – 30 MHz
Remark:

                           Digital unterschrieben von Rachid                                                                             Digitally signed by christian.
                           Acharkaoui                                                                                                    lorenz@cetecom.com
                           DN: cn=Rachid Acharkaoui,                                                                                     DN: cn=christian.
                           o=CETECOM GmbH, ou=RC&EMC,
                           email=rachid.acharkaoui@cetecom.
                                                                                                                                         lorenz@cetecom.com
                           com, c=DE                                                                                                     Date: 2016.10.28 11:38:51
                           Datum: 2016.10.31 11:38:56 +01'00'                                                                            +02'00'
......................................................                                                         ....................................................
Dipl.-Ing. Rachid Acharkaoui                                                                                                      Dipl.-Ing. C. Lorenz
Responsible for test section                                                                                             Responsible for test report




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 4 of 17


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report :                                         MSc. Ajit Phadtare
Project leader:                                                       Dipl.-Ing. V. Krueger
Receipt of EUT:                                                       2016-02-29
Date(s) of test:                                                      2016-03-03 to 2016-10-10
Date of report:                                                       2016-10-28
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     Datalogic ADC S.r.l.
Address:                                                              Via S. Vitalino, 13
                                                                      40012, Lippo di Calderara di Reno (BO)
                                                                      ITALY

Contact person:                                                       Mr. Eucarpio Guarisco

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 5 of 17


3. Equipment under test (EUT)
3.1. EUT: Type, S/N etc. and short descriptions used in this test report

 Short
                                                                     S/N              HW                  SW
 descrip-             EUT                      Type
                                                                serial number    hardware status     software status
 tion*)
                                                                                                     SW
                                            Type :                                  Beta HW
                                                                                                Version:WEC7
  EUT A       JOYA TOUCH              P00AN04HL0GT0W7           Z16P00014           Version
                                                                                                  Firmware
                                            -GRR                                 P/N:911350013
                                                                                                 Version: 2.16
                                                                                                     SW
                                                                                    Beta HW
                                     P00AN04HL0HT0W7                                            Version:WEC7
  EUT B       JOYA TOUCH                                        Z16P00044            Version
                                              -GR0                                                Firmware
                                                                                P/N:911350015
                                                                                                 Version: 2.16
                                                                                                     SW
                                                                                    Beta HW
                                     P00AN04HL0GT0W7                                            Version:WEC7
  EUT C       JOYA TOUCH                                        Z16P00015            Version
                                              -GRR                                                Firmware
                                                                               P/N: 9113500013
                                                                                                 Version: 2.16
*) EUT short description is used to simplify the identification of the EUT in this test report.



3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

    AE
                                                                      S/N              HW                 SW
   short     Auxiliary Equipment               Type
                                                                 serial number    hardware status    software status
 descrip-
  tion *)
                                                                                    Beta 2 HW
                                            Type :                                   Version
              JOYA TOUCH 3-                                                                           Firmware
  AE 1                                P00AN04HL0GT0W7             Z15P00991
               SLOT CRADLE                                                         P/N:91ACC00       Version: 1.1.1
                                            -GRR
                                                                                        43

               AC/DC Adapter                                                  230 V AC 50
                                                                331210680014
  AE 2                                   EA10681U-120                        Hz to 12VDC 6                  --
             EDACPOWER ELEC                                          C3
                                                                                    A
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.3. EUT set-ups

 EUT set-up
                        Combination of EUT and AE                                     Remarks
   no.*)

                      EUT A + EUT B + EUT C + AE 1             AC Power Lines Conducted emissions. All 3 EUTs
    set. 1
                                + AE 2                                 were set in the craddle (AE1).
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 6 of 17

3.4. EUT operating modes

    EUT
                      Description of
  operating                                                             Additional information
                     operating modes
 mode no.*)
                                           With help of Instructions given in “JOYANG_Test-
                                           Tools_Quick_Start_Instructions_rev20160422”

                                           Activated transmitters on EUT A to EUT B in order to check for
                                           repercussion on AC-mains emission, if wireless modes are activated:
                                                    WLAN 2.4 GHz transmitter functions
                       Transmitter
     op. 1                                          WLAN 5 GHz transmitter functions
                     Functions Mode
                                                    Bluetooth transmitter functions

                                   Other possible wireless technologies were completely deactivated in this
                                   mode
                                    NFC (not tested within this test report)
                                    battery charging option (WPC) (not tested within this test report)
*) EUT operating mode no. is used to simplify the test report.



3.5. Additional declaration and description of AE1
(Applicant's declaration,  = not selected,  = selected)
                                                             table-top           typical use           typical operating
                                                                                                        cycle of EUT.
 EUT A to EUT C                                              floor-standing  portable use              < 0.5 sec.
                                                             wall-mounted  fixed use                   :
                                                             not defined       vehicular use
                                                             Residential, commercial and light industry
 Place of use                                                Industrial environment
                                                             vehicular uses
 Highest internal frequency generated by EUT                 less than 108 MHz       -> up to 1 GHz
 and required upper frequency of radiated                    108 MHz - 500 MHz       -> up to 2 GHz**
 disturbance measurement                                    (**Assumed frequency range     No declaration from manufacturer)
                                                             500 MHz - 1 GHz              -> up to 5 or 6 GHz
 Power line:                                                EUT-grounding:
             L1,  L2,         L3,      N                 none                              (in case of deviation during tests the
  AC
            120 V AC 60 Hz (for AE 1)                                                              single details are described on
             24V,  120V,  400V                            with power supply                               chapter 4)
  DC
             12V for EUT A (from AE1)                       additional:
 Other Ports                                                 possible total cable length           shielding         connected
                                                                                                                     during test
 (description of interconnecting cables)
                               Connector
                                                  < 3m         > 3m               screened                           yes
                --                            --
                                                  : other                          unscreened                         no
 Does EUT contain devices susceptible to magnetic fields, e.g. Hall elements, electrodynamics                           yes
 microphones, etc.?                                                                                                     no
                                                                                                                        yes
 Is mounting position / usual operating position defined?
                                                                                                                        no




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 7 of 17

3.6. Configuration of cables used for testing
  Cable
                                                          S/N             HW           Cable length
 number               Item                    Type
                                                     serial number   hardware status
Cable 1                --                      --         --               --               --




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 8 of 17


4. Description of test system set-up’s

4.1. Test system set-up for AC power-line conducted emission measurements


 Specification:              ANSI C63.4-2014 chapter 7, ANSI C63.10-2013chapter 6.2

 General Description:        The radio frequency voltage conducted back into the AC power line in the frequency
                             range 150 kHz to 30 MHz has to be investigated. Compliance should be tested by
                             measuring the radio frequency voltage between each power line and ground at the
                             power terminals in the stated frequency range.
                             A 50 Ohm / 50 µH line impedance stabilization network (LISN) is used coupling the
                             interface to the measurement equipment. The EUT power input leads are connected
                             through the LISN to the AC-power source. The LISN enclosure is electrically
                             connected to the ground plane. The measuring instrument is connected to the coaxial
                             output of the LISN.
                             Tabletop devices were set-up on a 80 cm height above reference ground plane, floor
                             standing equipment 10 cm raised above ground plane. Measurements have been
                             performed on each phase line and neutral line of the devices AC-power lines. The
                             EUT was power supplied with 110 V/60 Hz. The EUT was tested in the defined
                             operating mode and installed (connected) to accessory equipment according the
                             general description of use given by the applicant.

 Schematic:




                             Only schematic view, we refer to figure 6, 7 and 8 of ANSI C63.4-2009 for more details.



 Testing method:             Exploratory, preliminary measure-                  Final testing for power phases and
                             ments as a first step, determines the              critical frequencies (Margin to AV- or QP
                             worst-case phase line (neutral or phase)           limit lower than 3 dB) as a second step
                             as well as the most critical operating             includes measurements with receivers
                             mode of the equipment. A complete                  detector set to Quasi-Peak and Average.
                             frequency-sweep with PK-Detector is
                             performed on each current-carrying
                             conductor.
 Formula:                    VC= VR + CL (1)                          VC = measured Voltage –corrected value
                             M= LT-VC (2)                             VR = Receiver reading
                                                                      CL = Cable loss
                                                                      M = Margin
                                                                      LT = Limit
                             Values are in dB, positive margin means value is below limit.




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 9 of 17


5. Measurements
5.1. General Limit - Conducted emissions on AC-Power lines
5.1.1. Test location and equipment
test location    CETECOM Essen (Chapter 2.2.1)      Please see Chapter 2.2.2           Please see Chapter 2.2.3
 test site       333 EMI field  348 EMI cond.
 receiver        001 ESS         377 ESCS 30       489 ESU 40        620 ESU 26
 LISN            005 ESH2-Z5  007 ESH3-Z6  300 ESH3-Z5 & 50 used for AE              no LISN for AE
 signaling       392 MT8820A  436 CMU              547 CMU           594 CMW
 line voltage    12 VDC (for EUT A to EUT C supplied from AE1)          060 120 V 60 Hz via PAS 5000 (for AE1)



5.1.2. Requirements
          FCC               Part 15, Subpart C,
           IC               §15.207 Issue 4, Chapter 8.8, Table 3
                            RSS-Gen
         ANSI               C63.4-2014, § 5.2, 6, 7
              Frequency  Conducted limit Class B
                [MHz]               QUASI-Peak [dBµV]                                       AVERAGE [dBµV]
   Limit      0.15 – 0.5                  66 to 56*                                            56 to 46*
                0.5 – 5                       56                                                  46
                5 – 30                        60                                                  50
 Remark: * decreases with the logarithm of the frequency

5.1.3. Test condition and test set-up
Signal link to test system (if used):          air link  cable connection  none
EUT-grounding                                  none  with power supply  additional connection
Equipment set up                               table top                        floor standing
                                              (40 cm distance to reference       EUT stands isolated on reference ground plane (floor)
                                              ground plane (wall)
Climatic conditions                           Temperature: (22±3°C)             Rel. humidity: (40±20)%
                                               9 – 150 kHz,            RBW = 200 Hz, Step = 61 Hz
                   Scan data                   150 kHz – 30 MHz        RBW = 9 kHz,       Step = 4 kHz
 EMI-Receiver or                               other:
 Analyzer settings Scan-Mode                  6 dB EMI-Receiver Mode
                   Pre-measurement            Peak detector, Repetitive-Scan, max-hold, sweep-time 50 µs per frequency point
                   Final measurement          Average & Quasi-peak detector at critical frequencies
General measurement procedures                Please see chapter “Test system set-up for AC power line conducted emissions measurements”

5.1.4. Measurement results
The results are presented below in summary form only. For more information please see the diagrams
                              Set-up no.: 1                                                 EUT OP-mode no.: 1
  Diagram-                                    Power                                                                        Result
                      Used Detector                          Additional (scan-) information            Remarks
    No.                                        line
                                                         Activated Transmitters on EUT
                 Peak (pre-scan)                        A to EUT C:
    1.01         AV (final)                  L1/ N           o      WLAN 2.4 GHz                     Remark 1)             Pass
                 QP   (final)                                 o      WLAN 5 GHz
                                                                 o      Bluetooth
 Remarks:
 1.) For further details please refer chapter 11.1 for test result diagrams
 2.) Please refer Annex TR2-20842790-15-10d-Annex3 for relevant test setup photographs




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 10 of 17


 6. Measurement uncertainties
The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                        Calculated uncertainty based on a
      RF-Measurement          Reference          Frequency range                                                  Remarks
                                                                            confidence level of 95%
 Conducted emissions                     9 kHz - 150 kHz            4.0 dB
                            CISPR 16-2-1                                                                              -
 (U CISPR)                               150 kHz - 30 MHz           3.6 dB
 Radiated emissions                      30 MHz - 1 GHz             4.2 dB
                            CISPR 16-2-3                                                                           E-Field
 Enclosure                               1 GHz - 18 GHz             5.1 dB
 Disturbance power          CISPR 16-2-2 30 MHz - 300 MHz           -                                                 -
                                                                                                                 Substitution
 Power Output radiated             -           30 MHz - 4 GHz       3.17 dB
                                                                                                                 method
                                                                    Cel- Cel-
                                               Set-up No.                        BT1 W1          W2         --
                                                                     C1     C2
 Power Output conducted            -           9 kHz - 12.75 GHz    N/A 0.60 0.7 0.25           N/A         --        -
                                               12.75 - 26.5GHz      N/A 0.82      --   N/A      N/A         --
 Conducted emissions               -           9 kHz - 2.8 GHz      0.70 N/A 0.70 N/A           0.69        --    N/A - not
 on RF-port                                    2.8 GHz - 12.75GHz   1.48 N/A 1.51 N/A           1.43        --    applicable
                                               12.75 GHz - 18GHz    1.81 N/A 1.83 N/A           1.77        --
                                               18 GHz - 26.5GHz     1.83 N/A 1.85 N/A           1.79        --
                                                                    0.1272 ppm (Delta Marker)                    Frequency
 Occupied bandwidth                -           9 kHz - 4 GHz                                                     error
                                                                    1.0 dB                                       Power
                                   -                                0.1272 ppm (Delta Marker)                    Frequency
 Emission bandwidth                            9 kHz - 4 GHz                                                     error
                                   -                                See above: 0.70 dB                           Power
 Frequency stability               -           9 kHz - 20 GHz       0.0636 ppm                                         -
                                               150 kHz - 30 MHz     5.0 dB                                       Magnetic
 Radiated emissions                            30 MHz - 1 GHz       4.2 dB                                       field
                                   -
 Enclosure                                     1 GHz - 20 GHz       3.17 dB                                      E-field
                                                                                                                 Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 11 of 17


7. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




8. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                              FCC, Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
      (MRA US-EU                                                                              Commission
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)
          0003)                                                                               Laboratory Division, USA
 348                 Mains Ports Conducted Interference Measurements
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-1967      Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 12 of 17


9. Instruments and Ancillary
9.1. Used equiment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


9.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053          Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140          Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355          Power Meter                               URV 5                    891310/027          Firm.= 1.31
365          10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
598          Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670          Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689          Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 13 of 17



9.1.2. Single instruments and test systems
  Ref.-No.




                                                                                                                          calibration
                                                                                                                          Interval of



                                                                                                                                            Remark
                            Equipment                           Type                Serial-No.        Manufacturer                                       Cal
                                                                                                                                                         due

001          EMI Test Receiver                         ESS                     825132/017        Rohde & Schwarz          12 M          -            30.05.2017
005          AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005        Rohde & Schwarz          12 M          -            30.05.2017
007          Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002        Rohde & Schwarz          12 M          -            30.05.2017
009          Power Meter (EMS-radiated)                NRV                     863056/017        Rohde & Schwarz          24 M          -            30.04.2017
016          Line Impedance Simulating Network         Op. 24-D                B6366             Spitzenberger+Spies      36 M          -            30.05.2019
020          Horn Antenna 18 GHz (Subst 1)             3115                    9107-3699         EMCO                     36/12 M       -            31.03.2017
021          Loop Antenna (H-Field)                    6502                    9206-2770         EMCO                     36 M          -            30.04.2018
030          Loop Antenna (H-field)                    HFH-Z2                  879604/026        Rohde & Schwarz          36 M          -            30.04.2018
033          RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18         Rohde & Schwarz          24 M          -            30.04.2017
057          relay-switch-unit (EMS system)            RSU                     494440/002        Rohde & Schwarz          pre-m         1a
060          power amplifier (DC-2kHz)                 PAS 5000                B6363             Spitzenberger+Spies      -             3
                                                       WRCT 1900/2200-5/40-
066          notch filter (WCDMA; FDD1)                                        5                 Wainwright GmbH          12 M          1g           30.06.2016
                                                       10EEK
086          DC - power supply, 0 -10 A                LNG 50-10               -                 Heinzinger Electronic    pre-m         2
087          DC - power supply, 0 -5 A                 EA-3013 S               -                 Elektro Automatik        pre-m         2
091          USB-LWL-Converter                         OLS-1                   007/2006          Ing. Büro Scheiba        -             4
099          passive voltage probe                     ESH2-Z3                 299.7810.52       Rohde & Schwarz          36 M          -            30.04.2018
100          passive voltage probe                     Probe TK 9416           without           Schwarzbeck              36 M          -            30.04.2018
110          USB-LWL-Converter                         OLS-1                   -                 Ing. Büro Scheiba        -             4
119          RT Harmonics Analyzer dig. Flickermeter   B10                     G60547            BOCONSULT                36 M          -            30.05.2019
136          adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697         EMCO                     36 M          -            30.04.2018
140          Signal Generator                          SMHU                    831314/006        Rohde & Schwarz          24 M          -            30.05.2018
248          attenuator                                SMA 6dB 2W              -                 Radiall                  pre-m         2
249          attenuator                                SMA 10dB 10W            -                 Radiall                  pre-m         2
252          attenuator                                N 6dB 12W               -                 Radiall                  pre-m         2
256          attenuator                                SMA 3dB 2W              -                 Radiall                  pre-m         2
257          hybrid                                    4031C                   04491             Narda                    pre-m         2
260          hybrid coupler                            4032C                   11342             Narda                    pre-m         2
261          Thermal Power Sensor                      NRV-Z55                 825083/0008       Rohde & Schwarz          24 M          -            30.05.2018
262          Power Meter                               NRV-S                   825770/0010       Rohde & Schwarz          24 M          -            30.05.2018
263          Signal Generator                          SMP 04                  826190/0007       Rohde & Schwarz          36 M          -            30.05.2019
265          peak power sensor                         NRV-Z33, Model 04       840414/009        Rohde & Schwarz          24 M          -            30.05.2018
266          Peak Power Sensor                         NRV-Z31, Model 04       843383/016        Rohde & Schwarz          24 M          -            30.05.2018
267          notch filter GSM 850                      WRCA 800/960-6EEK       9                 Wainwright GmbH          pre-m         2
270          termination                               1418 N                  BB6935            Weinschel                pre-m         2
271          termination                               1418 N                  BE6384            Weinschel                pre-m         2
272          attenuator (20 dB) 50 W                   Model 47                BF6239            Weinschel                pre-m         2
273          attenuator (10 dB) 100 W                  Model 48                BF9229            Weinschel                pre-m         2
274          attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321            Weinschel                pre-m         2
275          DC-Block                                  Model 7003 (N)          C5129             Weinschel                pre-m         2
276          DC-Block                                  Model 7006 (SMA)        C7061             Weinschel                pre-m         2
279          power divider                             1515 (SMA)              LH855             Weinschel                pre-m         2
287          pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P    379418            Miteq                    12 M          1c           30.06.2017
291          high pass filter GSM 850/900              WHJ 2200-4EE            14                Wainwright GmbH          12 M          1c           30.06.2017
298          Univ. Radio Communication Tester          CMU 200                 832221/091        Rohde & Schwarz          pre-m         3
300          AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020       Rohde & Schwarz          12 M          -            30.05.2017
301          attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272            Lucas Weinschel          pre-m         2
302          horn antenna 40 GHz (Meas 1)              BBHA9170                155               Schwarzbeck              36 M          -            31.03.2017
303          horn antenna 40 GHz (Subst 1)             BBHA9170                156               Schwarzbeck              36 M          -            31.03.2017
331          Climatic Test Chamber -40/+80 Grad        HC 4055                 43146             Heraeus Vötsch           Pre-m         2
341          Digital Multimeter                        Fluke 112               81650455          Fluke                    24 M          -            30.05.2018
342          Digital Multimeter                        Voltcraft M-4660A       IB 255466         Voltcraft                24 M          -            30.04.2017
347          laboratory site                           radio lab.              -                 -                        -             5
348          laboratory site                           EMI conducted           -                 -                        -             5
354          DC - Power Supply 40A                     NGPE 40/40              448               Rohde & Schwarz          pre-m         2
355          Power Meter                               URV 5                   891310/027        Rohde & Schwarz          24 M          -            30.05.2018
357          power sensor                              NRV-Z1                  861761/002        Rohde & Schwarz          24 M          -            30.04.2017
371          Bluetooth Tester                          CBT32                   100153            R&S                      36 M          -            30.05.2019
373          Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535            Rohde & Schwarz          12 M          -            30.05.2017
377          EMI Test Receiver                         ESCS 30                 100160            Rohde & Schwarz          12 M          -            30.05.2017
389          Digital Multimeter                        Keithley 2000           0583926           Keithley                 24 M          -            30.04.2017
392          Radio Communication Tester                MT8820A                 6K00000788        Anritsu                  12 M          -            30.05.2017
431          Model 7405                                Near-Field Probe Set    9305-2457         EMCO                     -             4
436          Univ. Radio Communication Tester          CMU 200                 103083            Rohde & Schwarz          12 M          -            30.04.2017
439          UltraLog-Antenna                          HL 562                  100248            Rohde & Schwarz          36 M          -            31.03.2017
                                                       System CTC-FAR-EMI-                       ETS-Lindgren /
443          CTC-FAR-EMI-RSE                                                   -                                          12 M          5            30.06.2017
                                                       RSE                                       CETECOM
                                                       WRCT 1850.0/2170.0-                       Wainwright Instruments
448          notch filter WCDMA_FDD II                                         5                                          12 M          1c           30.06.2017
                                                       5/40-                                     GmbH


TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 14 of 17
  Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                              Equipment                           Type                     Serial-No.              Manufacturer                                   Cal
                                                                                                                                                                  due

                                                       WRCT 824.0/894.0-5/40-
449          notch filter WCDMA FDD V                                              1                       Wainwright              12 M          1c           30.06.2017
                                                       8SSK
454          Oscilloscope                              HM 205-3                    9210 P 29661            Hameg                   -             4
456          DC-Power supply 0-5 A                     EA 3013 S                   207810                  Elektro Automatik       pre-m         2
459          DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50               910722                  Elektro Automatik       pre-m         2
460          Univ. Radio Communication Tester          CMU 200                     108901                  Rohde & Schwarz         12 M          -            30.04.2017
463          Universal source                          HP3245A                     2831A03472              Agilent                 -             4
466          Digital Multimeter                        Fluke 112                   89210157                Fluke USA               24 M          -            30.05.2018
467          Digital Multimeter                        Fluke 112                   89680306                Fluke USA               36 M          -            30.04.2018
468          Digital Multimeter                        Fluke 112                   90090455                Fluke USA               36 M          -            30.04.2018
477          ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink   -             3
480          power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz         24 M          -            30.04.2017
482          filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)           -             1d
                                                       AMF-5D-02501800-25-
484          pre-amplifier 2,5 - 18 GHz                                            1244554                 Miteq                   12 M          -            30.06.2017
                                                       10P
                                                       System EMI field (SAR)                              ETS Lindgren /
487          System CTC NSA-Verification SAR-EMI                                   -                                               24 M          -            31.07.2017
                                                       NSA                                                 CETECOM
489          EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz         12 M          -            30.05.2017
                                                       WRCG 1709/1786-
502          band reject filter                                                    SN 9                    Wainwright              pre-m         2
                                                       1699/1796-
503          band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright              pre-m         2
                                                       WRCA 800/960-02/40-
512          notch filter GSM 850                                                  SN 24                   Wainwrght               12 M          1c           30.06.2017
                                                       6EEK
517          relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                pre-m         2
523          Digital Multimeter                        L4411A                      MY46000154              Agilent                 24 M          -            30.04.2017
529          6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel               pre-m         2
530          10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                       pre-m         2
546          Univ. Radio Communication Tester          CMU 200                     106436                  R&S                     12 M          -            30.05.2017
547          Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz         12 M          -            30.04.2017
549          Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz         36/12 M       -            31.07.2018
             System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                                -                                               24 M          -            31.07.2017
             EMI                                       VSWR                                                Lindgren/CETECOM
552          high pass filter 2,8-18GHz                WHKX 2.8/18G-10SS           4                       Wainwright              12 M          1c           30.06.2017
557          System CTC-OTA-2                          R&S TS8991                  -                       Rohde & Schwarz         12 M          5            30.09.2016
                                                       System CTC FAR S-
558          System CTC FAR S-VSWR                                                 -                       CTC                     24 M          -            19.04.2017
                                                       VSWR
574          Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia               36/12 M       -            31.03.2019
584          Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz         pre-m         -
594          Wideband Radio Communication Tester       CMW 500                     101757                  Rohde & Schwarz         12 M          -            30.04.2017
597          Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz         pre-m         -
598          Spectrum Analyzer                         FSEM 30 (Reserve)           831259/013              Rohde & Schwarz         24 M          -            30.04.2017
600          power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz         24 M          -            30.04.2017
601          medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz         24 M          -            30.04.2017
602          peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz         24 M          -
611          DC power supply                           E3632A                      KR 75305854             Agilent                 pre-m         2
612          DC power supply                           E3632A                      MY 40001321             Agilent                 pre-m         2
613          Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                 pre-m         2
616          Digitalmultimeter                         Fluke 177                   88900339                Fluke                   24 M          -            30.05.2018
617          Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits           -             2
618          Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA      -             2
619          Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA     -             3
620          EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz           12 M          -            30.05.2017
621          Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz         pre-m         2
625          Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                 -             2
                                                                                   201.0999.9302.6.4.1.4
627          data logger                               OPUS 1                                              G. Lufft GmbH           24 M          -            30.04.2017
                                                                                   3
634          Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz         pre-m         2
                                                       HDMI cable with Ethernet
637          High Speed HDMI with Ethernet 1m                                      -                       KogiLink                -             2
                                                       1m
638          HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                -             2
640          HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                -             2
641          HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                -             2
644          Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits           -             -
670          Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz         24 M          -            30.05.2018
671          DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik       pre-m         2
678          Power Meter                               NRP                         101638                  Rohde&Schwarz           pre-m         -
683          Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz         12 M          -            30.05.2017
                                                                                                           Narda Safety Test
686          Field Analyzer                            EHP-200A                    160WX30702                                      24 M          -            30.04.2017
                                                                                                           Solutions
687          Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz           12 M          -            30.05.2017
688          Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                   pre-m         -
690          Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz           12 M          -            30.05.2017
692          Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz         36 M          -            31.03.2017


TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 15 of 17
  Ref.-No.




                                                                                                                                          calibration
                                                                                                                                          Interval of



                                                                                                                                                            Remark
                              Equipment                            Type                    Serial-No.              Manufacturer                                      Cal
                                                                                                                                                                     due

697          Power Splitter                             ZN4PD-642W-S+                165001445                Mini-Circuits               -             2




9.1.3. Legend

Note / remarks                               Calibrated during system calibration:
                                   1a        System CTC-SAR-EMS (Ref.-No. 442)
                                   1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                                   1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                   1d        System CTC-SAR-EMI (Ref.-No . 441)
                                   1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                   1f        System CTC-CTIA-OTA (Ref.-No . 420)
                                   1g        System CTC-FAR-EMS (Ref.-No . 444)
                                   2         Calibration or equipment check immediately before measurement
                                   3         Regulatory maintained equipment for functional check or support purpose
                                   4         calibrationequipment
                                             Ancillary   of this equipment
                                                                   without has no effect
                                                                           calibration   onmechanical
                                                                                       e.g. measuring equipment
                                                                                                      result    or monitoring equipment
                                   5         Test System


Interval of calibration            12 M      12 month
                                   24 M      24 month
                                   36 M      36 month
                                   24/12 M   Calibration every 24 months, between this every 12 months internal validation
                                   36/12 M   Calibration every 36 months, between this every 12 months internal validation
                                   Pre-m     Check before starting the measurement
                                   -         Without calibration




10. Versions of test reports (change history)

             Version             Applied changes                                                                                      Date of release
               --                Initial release                                                                                       2016-10-28
               --                --                                                                                                         --
               --                --                                                                                                         --




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 16 of 17


11. Measurement diagrams

                              Diagram No.: 1.01_Transmitter Functions_ Conducted emissions
Common Information
  Test Description:                                     Conducted Voltage Measurement Class B
  Test Site & Location:                                 Conducted Emission, CETECOM GmbH Essen
  Test Software:                                        R&S EMC32 v9.15
  Test Specification:                                   FCC 15.207
  Operating Mode:                                       Transmitter Functions Mode ( WLAN 2.4 GHz +WLAN 5GHz +Bluetooth)
  Measured on line:                                     N/L1
  Diagram details:                                      Shows the peak values as a sum of measured ports in maxhold mode
  Environmental Conditions:                             Humidity: 48%rH; Temperature: 21°C
  Operator:                                             HLa
  Test Mode:                                            Cradle with AC/DC Power Supply & Fully charged terminals inserted in all
                                                        three slots
  JOYA TOUCHTerminals:                                  Slot 1: EUT Type :P00AN04HL0HT0W7-GR0 | S/N:Z16P00044
                                                        Slot 2:EUT Type :P00AN04HL0GT0W7-GRR | S/N:Z16P00014
                                                        Slot 3:EUT Type :P00AN04HL0GT0W7-GRR | S/N:Z16P00015

EUT Information
  Manufacturer:                                         Datalogic ADCL S.r.l.
  MODEL:                                                JOYA TOUCH 3-SLOT CRADLE
  EuT Type:                                             --
  P/N:                                                  91ACC0043
  S/N:                                                  Z15P00991
  HW Version:                                           Beta 2
  Firmware Version:                                     1.1.1
  Input:                                                12VDC 6 A using AC/DC Adapter
  AC/DC Adapter Type:                                   100-240 VAC-2.0A 50-60Hz to 12VDC 6 A
  AC/DC Adapter Model:                                  EA10681U-120
  AC/DC Manufacturer:                                   EDACPOWER ELEC.
  EuT Mode:                                             Transmitter Functions Mode ( WLAN 2.4 GHz +WLAN 5GHz +Bluetooth)

                                                                   F u ll S p e c tru m


                         90


                         80


                         70

                                                                                                           C la s s B V o lta g e Q P
                         60
         Level in dBµV




                                                                                                            C la s s B V o lta g e A V
                         50


                         40


                         30


                         20


                         10


                         0
                         150k        3 0 0 4 0 05 0 0   8 0 01 M           2M      3M 4M 5M 6        8 10M            20M    30M
                                                                     F re q u e n c y in H z




TR2_20842790_15_10d


Test Report 2-20842790-15-10d, Page 17 of 17

Final_Result
        Frequency          QuasiPeak       CAverage     Limit   Margin
                                                                         Line   PE
          (MHz)             (dBµV)          (dBµV)     (dBµV)    (dB)
         0.181250              ---             39.88   54.43    14.55    L1     GND
         0.181250            45.78              ---    64.43    18.65    L1     GND
         0.200781              ---             38.07   53.58    15.51    L1     GND
         0.200781            44.32              ---    63.58    19.26    L1     GND
         0.239844              ---             38.16   52.10    13.94    L1     GND
         0.239844            43.40              ---    62.10    18.70    L1     GND
         0.263281              ---             34.43   51.33    16.90    L1     GND
         0.263281            39.76              ---    61.33    21.57    L1     GND
         0.298438              ---             33.80   50.29    16.49    L1     GND
         0.298438            39.09              ---    60.29    21.20    L1     GND
         0.427344              ---             34.50   47.30    12.80    L1     GND
         0.427344            39.71              ---    57.30    17.59    L1     GND
         0.474219              ---             35.13   46.44    11.31    L1     GND
         0.474219            40.37              ---    56.44    16.07    L1     GND
         1.278906              ---             25.55   46.00    20.45    L1     GND
         1.278906            29.92              ---    56.00    26.08    L1     GND
         6.181250            38.89              ---    60.00    21.11     N     GND
         6.181250              ---             34.63   50.00    15.37     N     GND
         18.060156           30.74              ---    60.00    29.26    L1     GND
         18.060156             ---             26.39   50.00    23.61    L1     GND




TR2_20842790_15_10d