                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 1 of 27




                ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT
                                          UN-INTENTIONAL RADIATOR CERTIFICATION TO
                                FCC PART 18 SUBPART C VERIFICATION REQUIREMENT
                                                                                                      OF

                               Product Name:                                Joya Touch Single Slot Dock Charge Only

                               Brand Name:                                 DATALOGIC

                               Model No.:                                  Joya Touch Single Slot Dock Charge Only

                               Added Model(s): N/A
                               Based on SGS
                                                                           E1/2017/70205
                               EMC Report No.:

                               Issue Date:                                 Feb. 26, 2018

                               FCC Rule Part:                              FCC Rules and Regulatiens Part 18(2016)

                               Prepared for:                               Datalogic S.r.l.
                                                                           Via S. Vitalino, 13-40012 Lippo di
                                                                           Calderara di Reno (BO) - Italy
                               Prepared by:                                SGS Taiwan Ltd.
                                                                           Electronics & Communication Laboratory
                                                                           No.2, Keji 1st Rd., Guishan Dist., Taoyuan
                                                                           City 333, Taiwan (R.O.C.)




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 2 of 27




                                                              DECLARATION OF COMPLIANCE

              Applicant:                                              Datalogic S.r.l.
                                                                      Via S. Vitalino, 13-40012 Lippo di Calderara di Reno (BO) - Italy
              Manufacturer:                                           Datalogic S.r.l.
                                                                      Via S. Vitalino, 13-40012 Lippo di Calderara di Reno (BO) - Italy
              Equipment Under Test:                                   Joya Touch Single Slot Dock Charge Only
              Brand Name:                                             DATALOGIC
              Model No.:                                              Joya Touch Single Slot Dock Charge Only
              Added Model(s) :                                        N/A
              Model Difference:                                       N/A
              File Number:                                            MH/2018/10207
              Date of EUT Received:                                   Jan. 19, 2018
             For the configuration tested, the EUT complied with the standards specified on Page 1.
             Remarks:
              We hereby certify that:
                  The above equipment was tested by SGS Taiwan Ltd. The test data, data evaluation, test procedures,
              and equipment configurations shown in this report were made in accordance with the procedures given in
              ANSI C63.4 :2014, MP-5 and the energy emitted by the sample EUT tested as described in this report is in
              compliance with conducted and radiated emission limits of FCC Rules Part 18
              The test results of this report relate only to the tested sample identified in this report.




               Approved By                                                                                              Date                           Feb. 26, 2018


                                                    Tony Hsu (Asst. Manager)




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 3 of 27




                                                                                                    Version

                Report Number                                         Version No.                                  Description                                    Date
                  E1/2017/70205                                         00                                       Original report                                    Oct. 26, 2017
                                                                                                                   Added FCC ID:
                  MH/2018/10207                                         01                                                                                         Feb. 26, 2018
                                                                                                                   U4GJNGSSDLITE




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 4 of 27




                                                                                     Contents
             1. GENERAL INFORMATION ..................................................................................................................... 5

                  1.1 APPLICANT & MANUFACTURER INFORMATION ....................................................................................... 5
                  1.2 GENERAL DESCRIPTION OF EUT .......................................................................................................... 5
                  1.3 DETAILS OF EUT ................................................................................................................................. 5
                  1.4 OPERATION PROCEDURE ..................................................................................................................... 6
                  1.5 DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 6
                  1.6 MODIFICATION LIST .............................................................................................................................. 6
                  1.7 ACCESSORIES CABLE LIST ................................................................................................................... 6
                  1.8 TEST SET-UP CONFIGURATION ............................................................................................................. 6
                  1.9 MEASURMENT PROCEDURE .................................................................................................................. 7
                  1.10 STANDARDS APPLICABLE FOR TESTING ............................................................................................... 7
                  1.11 SUMMARY OF RESULTS ...................................................................................................................... 7

             2. EMISSION ............................................................................................................................................... 8

                  2.1 TEST RESULTS .................................................................................................................................... 8
                  2.2 FREQUENCY RANGE............................................................................................................................. 8
                  2.3 LIMITS OF CONDUCTED AND RADIATED EMISSION .................................................................................. 9
                  2.3.1 LIMITS OF CONDUCTED EMISSION FOR FCC PART 18, SUBPART C ..................................................... 9
                  2.3.2 LIMITS OF RADIATED EMISSIONS FOR FCC PART 18, SUBPART C ..................................................... 11
                  2.4.TEST OF CONDUCTED EMISSION......................................................................................................... 13
                  2.4.1 TEST EQUIPMENTS ......................................................................................................................... 13
                  2.4.2 OPERATING ENVIRONMENT ............................................................................................................. 13
                  2.4.3 MEASUREMENT DATA...................................................................................................................... 14
                  2.5 TEST OF RADIATED EMISSION ............................................................................................................. 16
                  2.5.1 TEST INSTRUMENTS ........................................................................................................................ 16
                  2.5.2 OPERATING ENVIRONMENT ............................................................................................................. 16
                  2.5.3 MEASUREMENT DATA (3M METHOD) ................................................................................................ 17

             3. PHOTOGRAPHS OF TEST .................................................................................................................. 21

             4. PHOTOGRAPHS OF PRODUCT.......................................................................................................... 23




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 5 of 27




                                                        1. General Information

                   1.1 Applicant & Manufacturer Information
                          Applicant                                                   : Datalogic S.r.l.
                          Address of Applicant         : Via S. Vitalino, 13-40012 Lippo di Calderara di
                                                         Reno (BO) - Italy
                          e-mail Address of Applicant: : Ruggero.Cacioppo@datalogic.com
                          Manufacturer                                                : Datalogic S.r.l.
                          Address of Manufacturer                                     : Via S. Vitalino, 13-40012 Lippo di Calderara di
                                                                                        Reno (BO) - Italy


                   1.2 General Description of EUT
                          Product Name                                                   : Joya Touch Single Slot Dock Charge Only
                          Brand Name                                                     : DATALOGIC
                          Model No.                                                      : Joya Touch Single Slot Dock Charge Only
                          Added Model(s)                                                 : N/A
                          Model Difference                                               : N/A
                          Maximum Energy Generated                                       : Charger:0 ~ 5W
                          FCC ID                                                         : U4GJNGSSDLITE


                   1.3 Details of EUT
                          Power Supply                                                   : AC 100~240V, 50~60Hz
                          Modes/Function                                                 : Mode 1. Charger mode
                          Worst case                                                     : CE, Below RE worst case :
                                                                                           Mode 1. Charger mode
                          Highest operate description                                    : 200 kHz
                          Adapter                                                        : Model No.: BI24-050300-I
                                                                                           I/P : AC 100-240V, 50/60Hz, 0.8A
                                                                                           O/P : DC 5V, 3A



Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 6 of 27




                   1.4 Operation Procedure
                          Mode 1
                          1. Let EUT connect to the transformer and peripheral PDA plug in the EUT to charge.
                          2. Start the test.


                   1.5 Description of Support Units
                        PRODUCT                                    MANUFACTURER                                            MODEL NO.                                 SERIAL NO.
                       Scanner PDA                                   DATALOGIC                                            JOYA TOUCH                                 E17E17511

                           Support Equipment Used in Tested Cable
             Cable Type                                       Core                 Length                                       Shielding/Non-shielding
             N/A                                              N/A                   N/A                                                   N/A


                   1.6 Modification List

                          No modification was made by SGS Taiwan Electronics & Communication Laboratory.


                   1.7 Accessories Cable List
             Cable Type                                                   Core               Length                                 Shielding/Non-shielding
             adapter dc output                                            N/A                 1.8m                                       Non-shielding


                   1.8 Test Set-Up Configuration
                          Mode 1
                                                                                                                 Scanner PDA




                                                                                                                       Dock
                                                          Adapter                                                     (EUT)
                                                           (EUT)




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 7 of 27




                   1.9 Measurment Procedure
                               Conducted Emission Testing was performed according MP-5 in a shielded room
                          with peripherals placed on a table, 0.8m high over a metal floor. It was located more
                          than required distance away from the shielded room wall.


                              Radiated Emission Testing was performed according to MP-5 at the semi-
                          anechoic chamber (10m) or 966 semi-anechoic chamber (3m) test site. The EUT
                          was placed on a 0.8m high table along with the peripherals. The turn table was
                          separated 3m from the antenna. Cables were placed in a position to produce
                          maximum emissions as determined by experimentation, and operation mode was
                          selected for production of maximum emission.


                               The frequencies and amplitudes of maximum emission were measured at
                          varying azimuths, antenna heights and antenna polarities. Maximum emission levels
                          are then reported.


                   1.10 Standards Applicable for Testing
                          Tests to be carried out under FCC Part 18, Subpart C
                                                                Test Standards                                                                             Status
                              FCC Part 18, Subpart C                                                                                                    Applicable
                              Deviation from Standard                                                                                                 No deviation


                   1.11 Summary of Results


                                                                            Highest Emission
                             Standard                                    Test Type  Result Phase/Pol.                                       Frequency(MHz)                    Margin(dB)
                                                                                              Line                                              10.7300                      -14.80 (AVG)
                                                            Conducted Emission      PASS
             FCC Part 18 Subpart C                                                           Neutral                                            0.1500                       -13.48 (AVG)
                                                            Radiated Emission       PASS      Hor.                                              0.0138                       -30.57 (QP)


                          Note: The EUT is non-comsumer / medical diathermy product. Refer to user manual
                                for detail information.



Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 8 of 27




                                                                             2. EMISSION
                   2.1 Test Results
                                                                                                                                               Results
                                     Conducted Emission                                                                                          Pass
                                     Radiated Emission                                                                                           Pass


                   2.2 Frequency Range
                          Conducted Emission : 9 kHz - 30 MHz
                          Radiated Emission :




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 9 of 27




                   2.3 Limits of Conducted and Radiated Emission

                   2.3.1 Limits of Conducted Emission for FCC Part 18, Subpart C
                              According to conduction limits stated in 18.307, when equipment designed to be
                          connected to the public utility (AC) power line, the radio frequency voltage that is
                          conducted back onto the AC power line on any frequency or frequencies shall not
                          exceed the limits in the following tables. Compliance with the provisions of this
                          paragraph shall be based on the measurement of the radio frequency voltage
                          between each power line and ground at the power terminal using a 50 μH/50 ohms
                          line impedance stabilization network (LISN).
                                   (a)        All induction cooking ranges and ultrasonic equipment:

                                        Frequency of                                        Conducted limit (dBμV)
                                      emission (MHz)                              Quasi-peak                                    Average

                                         0.009 – 0.05                                     110                                           -
                                          0.05 – 0.15                                90 – 80*                                           -
                                           0.15 – 0.5                                66 – 56*                                   56 – 46*
                                               0.5 - 5                                     56                                         46
                                                5 - 30                                     60                                         50
                                   *Decreases with the logarithm of the frequency




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 10 of 27



                                   (b)        All other part 18 consumer devices:

                                   Frequency of emission                                               Conducted limit (dBμV)
                                          (MHz)                                              Quasi-peak                                 Average
                                                0.15 – 0.5                                      66 – 56*                                56 – 46*
                                                   0.5 - 5                                            56                                      46
                                                    5 - 30                                            60                                      50
                                   *Decreases with the logarithm of the frequency
                                   (c)        RF lighting devices:

                                           Frequency                         Emissions                                        Emissions
                                              MHz                              (μV)                                            (dBμV)
                                                                       Non-consumer equipment:

                                            0.45 - 1.6                                   1000                                         60
                                             1.6 - 3.0                                   3000                                      69.54
                                                                           Consumer equipment:
                                          0.45 – 2.51                                     250                                         48
                                           2.51 – 3.0                                    3000                                       69.5
                                              3.0 - 30                                    250                                         48




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 11 of 27




                   2.3.2 Limits of Radiated Emissions for FCC Part 18, Subpart C
                               According to 18.305 (b), the field strength levels of emissions which lie outside
                          the bands specified in §18.301, unless otherwise indicated, shall not exceed the
                          following:

                                                     Operating              RF Power                Field Strength Limit                   Distance            Field Strength Limit @
                       Equipment                     Frequancy                 (watts)                        (μV/m)                       (Meters)                   3m (dBμV/m)
                                                                                                                                                                          68
                 Any type unless                                            Below 500                             25                           300
                                                      Any ISM
               otherwise specified
                                                     frequancy                                                                                1                       20 log(25x
                 (miscellaneous)                                          500 or more 25xSQRT(power/500)                                        300
                                                                                                                                                                  √(power/500)2)+40
                                                        Any                                                                                                              63.5
                                                                            Below 500                             15                           300
                                                      non-ISM
                                                     frequancy                                                                                                       20 log(25x
                                                                          500 or more 15xAQRT(power/500)                                       300                           2)
                                                                                                                                                                 √(power/500) +52.7
                                    On or below
                Industrial heaters                  Any                                                           10                          1,600                           64.5
                                     5,725 MHz
              and RF stabilized arc
                                    Above 5,725
                    welders                         Any                                                           (2)                             (2)                           ---
                                        MHz
                                      Any ISM
                                                    Any                                                           25                           300                              68
                                     frequency
               Medical diathermy
                                    Any non-ISM     Any                                                           15                           300                            63.5
                                     frequency
                                     Below 490                                                         2,400/F(kHz)                            300           20 log(2,400/F(kHz))+40
                                                 Below 500
                                        kHz                                                        2,400/F(kHz)×SQRT
                                                500 or more
                                                                                                       (power/500)                             300             20 log(2,400/F(kHz)) x
                                                                                                                                                                             2
                                                   490 to 1,600                                                                                                 √(power/500) )+60.8
                       Ultrasonic                                                Any
                                                       kHz                                               2,400/F(kHz)
                                                                                                                                                  30         20 log(2,400/F(kHz))+20
                                                     Above
                                                                                 Any
                                                    1,600kHz                                                      15                              30                          43.5
                                                    Below 90                                                                                    4
                                                       kHz                       Any                                                              30                          83.5
                                                                                                               1,500
                 Induction cooking
                                                   On or above
                      ranges
                                                     90 kHz                      Any                             300                            4                             69.5
                                                                                                                                                  30




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 12 of 27



                                   1 Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment operating
                                       below 1000 MHz is not permitted the increase in field strength otherwise permitted here for
                                       power over 500 watts.
                                   2 Reduced to the greatest extent possible.
                                   3 Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment is not permitted
                                       the increase in field strength otherwise permitted here for over 500 watts.
                                   4 Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field
                                       strength limits for miscellaneous ISM equipment.



                                   According to 18.305 (c), the field strength limits for RF lighting devices shall be
                          the following:


                                            Frequency                       Distance              Field Strength                    Field Strength Limit @ 3m
                                                (MHz)                       (Meters)                Limit (μV/m)                                  (dBμV/m)

                                                                                       Non-consumer equipment:
                                              30 - 88                            30                         30                                       49.54
                                              88 - 216                           30                         50                                          54
                                            216 - 1000                           30                         70                                        56.9
                                                                                          Consumer equipment:

                                              30 - 88                            30                         10                                          40
                                              88 - 216                           30                         15                                        43.5
                                            216 - 1000                           30                         20                                        46.1



                               According to 18.307(f): For ultrasonic equipment, compliance with the
                          conducted limits shall preclude the need to show compliance with the field strength
                          limits below 30 MHz unless requested by the Commission.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 13 of 27




                   2.4.Test of Conducted Emission

                   2.4.1 Test Equipments
                                   SGS Conducted_Emission HWAYA Conducted Room No.A_EMC
                                                                                               Calibration                                                                      Calibration
              EQUIPMENT TYPE            Manufacturer         Model Number        Serial Number
                                                                                                 Date                                                                              Due
               EMI Test Receiver            R&S                  ESCI 3             101311     2017/6/23                                                                        2018/6/22
                                      EMC Instruments
                 Coaxial Cables                         EMCRG58-BM-BM-3000          160812     2016/8/30                                                                         2017/8/29
                                            Corp
                      LISN            SCHWARZBECK              NSLK 8127           8127-648    2017/6/18                                                                         2018/6/17
                  Pulse Limiter         Narda S.T.S.           PMM PL01           1110X30602 2016/8/12                                                                           2017/8/11
                      LISN              Schwarzbeck            NSLK 8128        NSLK8128-300 2017/8/4                                                                            2018/8/3
                                                                                   Ver. SGS-
                    Test S/W               Farad                EZ-EMC                          N.C.R.                                                                             N.C.R.
                                                                                     03A2
             SGS Taiwan LTD. Electronics & Communication Laboratory
             No.2, Keji 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.)
             Measurement Uncertainty of Conducted Emission
             Expanded uncertainty (K=2) of conducted emission is 2.25 dB
             Expanded uncertainty (K=2) of ISN conducted emission is 2.57 dB



                   2.4.2 Operating Environment
                               Temperature : 25 degree C                                                       Humidity : 64 %RH
                               Atmospheric Pressure : 992 hpa




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 14 of 27




                   2.4.3 Measurement Data

                                                Model No.:Joya Touch Single Slot Dock Charge Only
                                                                   Mode_1_L




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 15 of 27




                                                                                             Mode_1_N




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 16 of 27




                   2.5 Test of Radiated Emission

                   2.5.1 Test Instruments
                                                               SGS Radiated_Below_1GHz HWAYA 966B_EMC
                 EQUIPMENT
                                                 Manufacturer                    Model Number                    Serial Number Calibration Date Calibration Due
                    TYPE
                  EMI Test
                                                        R&S                             ESR 7                         101507                     2017/5/27                   2018/5/26
                  Receiver
                  Biconical
                                                     TESEQ                          CBL 6112D                          35241                    2017/12/20                  2018/12/19
                   Antenna
                  Biconical
                                             SCHWARZBECK                           VHBB 9124                         9124-560                   2017/12/25                  2018/12/24
                   Antenna
                                             EMC Instruments
                 Pre Amplifier                                                       EMC330H                          980215                     2017/9/30                   2018/9/29
                                                  Corp.
               Coaxial Cable                 EMC Instruments
                                                     EMC8D-NM-NM           140919       2017/9/30         2018/9/29
               Coaxial Cable                 EMC Instruments
                                                     EMC8D-NM-NM           140921       2017/9/30         2018/9/29
                 DC LISN                     SCHWARZBECK
                                                      NNBM 8124           8124-564      2017/12/6         2018/12/5
                 DC LISN                     SCHWARZBECK
                                                      NNBM 8124           8124-565      2017/12/6         2018/12/5
              Communication
                                       R&S              CMU200             119988       2018/2/22         2019/2/21
                  Tester
              Communication
                                       R&S              CMW500             152303       2018/2/21         2019/2/20
                  Tester
              Communication
                                      Anritsu           MT8820C          6201465315     2017/12/10        2018/12/9
                  Tester
                 Controller             MF              MF-7802              N/A           N.C.R.           N.C.R.
              Antenna Master            MF                 N/A               N/A           N.C.R.           N.C.R.
                Turn Table             MF                  N/A               N/A           N.C.R.           N.C.R.
                 Site NSA              SGS           966 Chamber B         SAC-B        2017/10/8         2018/10/7
                 Test S/W             Farad             EZ-EMC           6201107337        N.C.R.           N.C.R.
               Loop Antenna       COM-POWER              AL-130            121060       2017/5/15         2018/5/14
             SGS Taiwan LTD. Electronics & Communication Laboratory
             No.2, Keji 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.)
             Measurement Uncertainty of Radiated Emission
             Expanded uncertainty Ulab (k=2) of radiated emission measurement is 4.59 dB. (30-1000MHz)
             Theory values uncertainty Ucispr 16-4-2:2011+A1:2014 (K=2) of radiated emission is 5.24 dB. (30MHz ~
             1000MHz)



                   2.5.2 Operating Environment
                              Temperature : 23 degree C                                                   Humidity : 68 %RH
                              Atmospheric Pressure : 1002 hpa




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 17 of 27




                   2.5.3 Measurement Data

                                                Model No.:Joya Touch Single Slot Dock Charge Only
                                                                   Mode_1_H




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 18 of 27




                                                                                             Mode_1_V




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 19 of 27




                                                                                0.150MHz ~ 30.000MHz
                                                                                     Mode_1_H




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                         Report No.: MH/2018/10207
                                                                    FCC ID: U4GJNGSSDLITE                                                Page: 20 of 27




                                                                                             Mode_1_V




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group



Document Created: 2018-03-19 13:11:42
Document Modified: 2018-03-19 13:11:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC