Test Report Part 18

FCC ID: U4GJNGSSD

Test Report

Download: PDF
FCCID_3720069

                        FCC Test Report

       Product Name              WIRELESS POWER TRANSMISSION SYSTEM
       Model No.                 JOYA TOUCH SINGLE SLOT DOCK LOCKING




Applicant         DATALOGIC SRL
Address           Via S. Vitalino 13, 40012 Lippo di Calderara di Reno (BO) – Italy




                       Date of Receipt             2017/08/14
                       Report No.                  1780285R-ITUSP04V00
                       Issued Date                 2017/10/27
                       Report Version              V2.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF or any agency of the Government.
The test report shall not be reproduced except in full without the written approval of DEKRA Testing and
Certification Co., Ltd.


Report No: 1780285R-ITUSP04V00



                     Te st Re p o r t Ce r ti f ic at i on
                                                         Issued Date     : 2017/10/27
                                                         Report No.     : 1780285R-ITUSP04V00




      Product Name          :    WIRELESS POWER TRANSMISSION SYSTEM
      Applicant             :    DATALOGIC SRL
      Address               :    Via S. Vitalino 13, 40012 Lippo di Calderara di Reno
                                 (BO) –   Italy
      Manufacturer          :    DATALOGIC SRL
      Model No.             :    JOYA TOUCH SINGLE SLOT DOCK LOCKING
      EUT Voltage           :    AC 100-240V, 50/60Hz
      Trade Name            :    Datalogic
      Applicable Standard   :    FCC Part 18: 2015, MP-5: 1986,
                                 RSS-216 Issue 2: 2016
                                 ANSI C63.4: 2014,
                                 ICES-001 Issue 4: 2006
      Test Result           :    Complied
      Laboratory Name       :    Hsin Chu Laboratory
      Address               :    No.372-2, Sec. 4, Zhongxing Rd., Zhudong Township,
                                 Hsinchu County 310, Taiwan, R.O.C.
                                 TEL: +886-3-582-8001 / FAX: +886-3-582-8958




      Documented By          :

                                          ( Lyla Yang / Engineering Adm. Specialist )


      Tested By              :

                                                  ( Hornet Liu / Senior Engineer )

      Approved By            :

                                                  ( Arthur Liu / Deputy Manager )




                                          Page: 2 of 34


Report No: 1780285R-ITUSP04V00


Laboratory Information

We , DEKRA Testing and Certification Co., Ltd., are an independent EMC and safety
consultancy that was established the whole facility in our laboratories. The test facility has been
accredited/accepted (audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scopes:


     Taiwan R.O.C.        :   BSMI, NCC, TAF
     USA                  :   FCC
     Japan                :   VCCI

The related certificate for our laboratories about the test site and management system can be downloaded
from DEKRA Testing and Certification Co., Ltd. Web Site:
http://www.dekra.com.tw/english/about/certificates.aspx?bval=5
The address and introduction of DEKRA Testing and Certification Co., Ltd. laboratories can be founded in
our Web site : http://www.dekra.com.tw/index_en.aspx

If you have any comments, Please don’t hesitate to contact us. Our test sites as below:

 1    No. 75-2, 3rd Lin, WangYe Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan (R.O.C.)
      TEL:+886-3-592-8858 / FAX:+886-3-592-8859        E-Mail : info.tw@dekra.com
 2    No.372, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County 31061, Taiwan, R.O.C.
      TEL: +886-3-582-8001 / FAX: +886-3-582-8958       E-Mail : info.tw@dekra.com
 3    No.372-2, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County 31061, Taiwan, R.O.C.
      TEL: +886-3-582-8001 / FAX: +886-3-582-8958       E-Mail : info.tw@dekra.com




                                              Page: 3 of 34


Report No: 1780285R-ITUSP04V00


                                               TABLE OF CONTENTS
Description                                                                                                                                Page
1.     General Information ................................................................................................................. 5
1.1.      EUT Description ................................................................................................................... 5
1.2.      Mode of Operation ............................................................................................................... 6
1.3.      Tested System Details .......................................................................................................... 7
1.4.      Configuration of Tested System ........................................................................................... 7
1.5.      EUT Exercise Software ........................................................................................................ 7
2.     Technical Test........................................................................................................................... 8
2.1.      Summary of Test Result ....................................................................................................... 8
2.2.      List of Test Equipment .......................................................................................................... 9
2.3.      Measurement Uncertainty .................................................................................................. 10
2.4.      Test Environment ............................................................................................................... 10
3.     Conducted Emission .............................................................................................................. 11
3.1.      Test Specification ............................................................................................................... 11
3.2.      Test Setup .......................................................................................................................... 11
3.3.      Limit.................................................................................................................................... 12
3.4.      Test Procedure ................................................................................................................... 12
3.5.      Test Result ......................................................................................................................... 14
3.6.      Test Photograph ................................................................................................................. 18
4.     Radiated Emission ................................................................................................................. 19
4.1.      Test Specification ............................................................................................................... 20
4.2.      Test Setup .......................................................................................................................... 20
4.3.      Limit.................................................................................................................................... 21
4.4.      Test Procedure ................................................................................................................... 23
4.5.      Test Result ......................................................................................................................... 24
4.6.      Test Photograph ................................................................................................................. 28
5.     Attachment ............................................................................................................................. 30
          EUT Photograph ................................................................................................................ 30




                                                                Page: 4 of 34


Report No: 1780285R-ITUSP04V00


1. General Information

1.1. EUT Description


    Product Name           WIRELESS POWER TRANSMISSION SYSTEM
    Trade Name             Datalogic
    Model No.              JOYA TOUCH SINGLE SLOT DOCK LOCKING

    Component
    Power Adapter          EDAC, EA10681U-120
                           I/P: 100-240V~2.0A, 50-60Hz
                           O/P: 12V    6A
                           Cable Out: Non-Shielded, 1.2m, two ferrite cores bonded.
                           Power Cord: Non-Shielded, 2m.

    Note:
     1. This EUT is a WIRELESS POWER TRANSMISSION SYSTEM.
     2. This device is a composite device in accordance with Part 18 regulations. The function for
         the transmitting was measured and made a test report that number is
         1780285R-RFUSP17V01, certified under FCC ID: U4GJNGSSD, IC ID: 3862E-JNGSSD.




                                          Page: 5 of 34


Report No: 1780285R-ITUSP04V00


1.2. Mode of Operation

DEKRA has verified the construction and function in typical operation. All the test modes were
carried out with the EUT in normal operation, which was shown in this test report and defined as:


 Pre-Test Mode
 Mode 1: Normal Operation (WPT+NFC)
 Final Test Mode
 Emission      Mode 1: Normal Operation (WPT+NFC)




                                          Page: 6 of 34


Report No: 1780285R-ITUSP04V00


1.3. Tested System Details

The types for all equipment, plus descriptions of all cables used in the tested system (including
inserted cards) are:


Product          Manufacturer       Model No.      Serial No.      FCC ID     Power Cord
 1 N/A


1.4. Configuration of Tested System

                                        Connection Diagram




1.5. EUT Exercise Software

  1   Test system is in accord with EUT user manual (refer to 1.4 configuration of tested system).
  2   Turn on the power of all equipment.
  3   Verify the model operation.




                                            Page: 7 of 34


Report No: 1780285R-ITUSP04V00


2. Technical Test

2.1. Summary of Test Result

    No deviations from the test standards
    Deviations from the test standards as below description:


Emission
                                                                  Test
Performed Item             Normative References                             Deviation   Test Site
                                                                Performed
Conducted Emission         FCC Part 18: 2015, RSS-216,            Yes          No          3
                           MP-5: 1986, ANSI C63.4: 2014
Radiated Emission          FCC Part 18: 2015, RSS-216,            Yes          No          2
                           MP-5: 1986, ANSI C63.4: 2014
Note: Test site information refers to Laboratory Information.




                                                Page: 8 of 34


Report No: 1780285R-ITUSP04V00


2.2. List of Test Equipment

Conducted Emission / SR2-H
Instrument                 Manufacturer   Model No.       Serial No.   Cal. Date    Next Cal. Date
Test Receiver              R&S            ESCS 30         836858/022   2017/04/12   2018/04/11
Artificial Mains Network   R&S            ENV4200         848411/010   2017/02/06   2018/02/05
LISN                       R&S            ENV216          100092       2017/07/31   2018/07/30
Coaxial Cable              Harbour        RG-400          SR2-H        2017/08/15   2018/08/14
Quietek EMI system         Quietek        Version 2.2     SR2-H        N/A          N/A


Radiated Emission / CB1-H (Under 1GHz)
Instrument                 Manufacturer   Model No.       Serial No.   Cal. Date    Next Cal. Date
EMI Test Receiver          R&S            ESR7            101762       2016/11/29   2017/11/28
EMI Test Receiver          R&S            ESR7            101761       2016/11/29   2017/11/28
Pre-Amplifier              QuieTek        AP-025C         CHM-0706049 2016/12/19    2017/12/18
Pre-Amplifier              QuieTek        AP-025C         CHM-0503002 2017/08/16    2018/08/15
Bilog Antenna              Schaffner      CBL6112B        2891         2017/08/15   2018/08/14
Bilog Antenna              Schaffner      CBL6112B        2914         2017/08/15   2018/08/14
                           Chase
Coaxial cable              Suhner         SF106_104_      10m-A        2016/12/05   2017/12/04
                                          SPUMA600
Coaxial cable              Suhner         SF106_104_      10m-B        2016/12/05   2017/12/04
                                          SPUMA600
Coaxial cable              Suhner         SF106_104       3m-A         2016/12/05   2017/12/04
Coaxial cable              Suhner         SF106_104       3m-B         2016/12/05   2017/12/04
Dr.E EMI system            World Pallas   Version 3.5     CB1-H        N/A          N/A


Radiated Emission (Loop) / SR2-H
Instrument                 Manufacturer   Model No.       Serial No.   Cal. Date    Next Cal. Date
Test Receiver              R&S            ESCS 30         836858/022   2017/04/12   2018/04/11
Triple Loop Antenna        Schwarzbeck    HXYZ 9170       D-69250      2016/11/22   2017/11/21
Quietek EMI system         Quietek        Version 2.2     SR2-H        N/A          N/A




                                          Page: 9 of 34


Report No: 1780285R-ITUSP04V00


2.3. Measurement Uncertainty


 Conducted Emission
     The measurement uncertainty is evaluated as ± 2.26 dB.
 Radiated Emission (Under 1GHz)
     The measurement uncertainty is evaluated as ± 3.43 dB.
 Radiated Emission (Under 30MHz)
     The measurement uncertainty is evaluated as ± 2.04 dB.




2.4. Test Environment


Performed Item        Items                           Required   Actual
                      Temperature ( C)                15-35      25
Conducted Emission Humidity (%RH)                     25-75      50
                      Barometric pressure (mbar)      860-1060   950-1000
                      Temperature ( C)                15-35      25
Radiated Emission
                      Humidity (%RH)                  25-75      65
(Under 1GHz)
                      Barometric pressure (mbar)      860-1060   950-1000
                      Temperature ( C)                15-35      25
Radiated Emission
                      Humidity (%RH)                  25-75      50
(Under 30MHz)
                      Barometric pressure (mbar)      860-1060   950-1000




                                         Page: 10 of 34


Report No: 1780285R-ITUSP04V00


3. Conducted Emission

3.1. Test Specification

     According to Standard : FCC Part 18, RSS-216, MP-5, ANSI C63.4


3.2. Test Setup




                                       Page: 11 of 34


Report No: 1780285R-ITUSP04V00


3.3. Limit

    FCC Part 18

                                           Limits

              Frequency                      QP                         AV
                (MHz)                      (dBuV)                     (dBuV)

             0.15 – 0.50                  66 – 56                     56 – 46


              0.50 – 5.0                     56                          46


               5.0 – 30                      60                          50

     Remarks: In the above table, the tighter limit applies at the band edges.


    RSS-216




                                          Page: 12 of 34


Report No: 1780285R-ITUSP04V00


3.4. Test Procedure

    FCC Part 18
     The EUT and simulators are connected to the main power through a line impedance
     stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the
     measuring equipment. The peripheral devices are also connected to the main power through
     a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination.
     (Please refers to the block diagram of the test setup and photographs.)
     Both sides of A.C. line are checked for maximum conducted interference. In order to find the
     maximum emission, the relative positions of equipment and all of the interface cables must
     be changed on conducted measurement.
     Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using
     a receiver bandwidth of 9kHz.


    RSS-216
     The EUT and simulators are connected to the main power through a line impedance
     stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the
     measuring equipment. The peripheral devices are also connected to the main power through
     a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination.
     (Please refers to the block diagram of the test setup and photographs.)
     Both sides of A.C. line are checked for maximum conducted interference. In order to find the
     maximum emission, the relative positions of equipment and all of the interface cables must
     be changed on conducted measurement.
     Conducted emissions were invested over the frequency range from 0.009MHz to 30MHz
     using a receiver, where the resolution bandwidth of the receiver is set as 200Hz at frequency
     range from 0.009MHz to 0.15MHz and set as 9KHz at frequency range from 0.15MHz to
     30MHz.




                                          Page: 13 of 34


Report No: 1780285R-ITUSP04V00


3.5. Test Result
FCC Part 18
Site : SR2-H                                                   Time : 2017/08/17

Limit : CISPR_B_00M_QP                                         Margin : 10

Probe : SR2_LISN(16A)-6_0712 - Line1                           Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                       Note : Mode 1: Normal Operation (WPT+NFC)




            Frequency      Correct Factor     Reading Level      Measure Level     Margin     Limit      Detector Type
               (MHz)           (dB)              (dBuV)             (dBuV)          (dB)      (dBuV)

   1    *          0.154              9.747           45.320             55.066     -10.720     65.786   QUASIPEAK

   2               0.154              9.747           22.700             32.446     -23.340     55.786      AVERAGE

   3               0.240              9.746           35.140             44.886     -17.216     62.102   QUASIPEAK

   4               0.240              9.746           16.830             26.576     -25.526     52.102      AVERAGE

   5               0.283              9.742           28.120             37.862     -22.871     60.733   QUASIPEAK

   6               0.283              9.742            9.940             19.682     -31.051     50.733      AVERAGE

   7               1.170              9.827           18.760             28.587     -27.413     56.000   QUASIPEAK

   8               1.170              9.827           17.190             27.017     -18.983     46.000      AVERAGE

   9               3.252              9.898           19.590             29.488     -26.512     56.000   QUASIPEAK

  10               3.252              9.898           18.430             28.328     -17.672     46.000      AVERAGE

  11              19.513           10.328              9.950             20.278     -39.722     60.000   QUASIPEAK

  12              19.513           10.328              2.980             13.308     -36.692     50.000      AVERAGE



Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor.


                                                    Page: 14 of 34


Report No: 1780285R-ITUSP04V00




Site : SR2-H                                                   Time : 2017/08/17

Limit : CISPR_B_00M_QP                                         Margin : 10

Probe : SR2_LISN(16A)-6_0712 - Line2                           Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                       Note : Mode 1: Normal Operation (WPT+NFC)




            Frequency      Correct Factor     Reading Level      Measure Level     Margin     Limit      Detector Type

               (MHz)           (dB)              (dBuV)             (dBuV)          (dB)      (dBuV)

   1               0.166              9.753           36.050             45.803     -19.374     65.177   QUASIPEAK

   2               0.166              9.753            8.860             18.613     -36.564     55.177      AVERAGE

   3    *          0.205              9.751           37.400             47.151     -16.268     63.418   QUASIPEAK

   4               0.205              9.751           15.470             25.221     -28.198     53.418      AVERAGE

   5               0.236              9.750           34.670             44.420     -17.818     62.238   QUASIPEAK

   6               0.236              9.750           15.250             25.000     -27.238     52.238      AVERAGE

   7               0.302              9.750           26.220             35.970     -24.208     60.178   QUASIPEAK

   8               0.302              9.750            7.670             17.420     -32.758     50.178      AVERAGE

   9               0.385              9.750           20.850             30.600     -27.576     58.176   QUASIPEAK

  10               0.385              9.750           12.010             21.760     -26.416     48.176      AVERAGE

  11               0.646              9.767           17.610             27.377     -28.623     56.000   QUASIPEAK

  12               0.646              9.767           13.370             23.137     -22.863     46.000      AVERAGE



Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor.



                                                    Page: 15 of 34


Report No: 1780285R-ITUSP04V00


RSS-216
Site : SR2-H                                                   Time : 2017/10/27

Limit : CNS13803_QP                                            Margin : 10

Probe : SR2_LISN(16A)-7_0731 - Line1                           Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                       Note : Mode 1: Normal Operation (WPT+NFC)




            Frequency      Correct Factor     Reading Level      Measure Level     Margin     Limit      Detector Type
               (MHz)           (dB)              (dBuV)             (dBuV)          (dB)      (dBuV)
   1               0.030              9.766           53.440             63.206     -46.794   110.000    QUASIPEAK
   2               0.050              9.629           44.580             54.209     -55.791   110.000    QUASIPEAK
   3               0.080              9.598           40.800             50.398     -36.602     87.000   QUASIPEAK
   4    *          0.166              9.690           41.810             51.500     -14.043     65.543   QUASIPEAK
   5               0.166              9.690           22.800             32.490     -33.053     65.543      AVERAGE
   6               0.181              9.690           38.510             48.200     -16.914     65.114   QUASIPEAK
   7               0.181              9.690           27.860             37.550     -27.564     65.114      AVERAGE
   8               0.267              9.690           25.460             35.150     -27.507     62.657   QUASIPEAK
   9               0.267              9.690            9.460             19.150     -43.507     62.657      AVERAGE
  10               0.330              9.690           19.480             29.170     -31.687     60.857   QUASIPEAK
  11               0.330              9.690           12.210             21.900     -38.957     60.857      AVERAGE
  12               4.834              9.827           16.420             26.247     -29.753     56.000   QUASIPEAK
  13               4.834              9.827           14.890             24.717     -31.283     56.000      AVERAGE
  14              19.591           10.281             20.420             30.701     -29.299     60.000   QUASIPEAK
  15              19.591           10.281             16.120             26.401     -33.599     60.000      AVERAGE


Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor.


                                                    Page: 16 of 34


Report No: 1780285R-ITUSP04V00




Site : SR2-H                                                   Time : 2017/10/27

Limit : CNS13803_QP                                            Margin : 10

Probe : SR2_LISN(16A)-7_0731 - Line2                           Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                       Note : Mode 1: Normal Operation (WPT+NFC)




            Frequency      Correct Factor     Reading Level      Measure Level     Margin     Limit      Detector Type
               (MHz)           (dB)              (dBuV)             (dBuV)          (dB)      (dBuV)
   1               0.030              9.735           52.960             62.695     -47.305   110.000    QUASIPEAK
   2               0.053              9.608           51.960             61.568     -28.132     89.700   QUASIPEAK
   3               0.076              9.589           38.680             48.269     -39.131     87.400   QUASIPEAK
   4    *          0.158              9.677           42.650             52.327     -13.444     65.771   QUASIPEAK
   5               0.158              9.677           24.380             34.057     -31.714     65.771      AVERAGE
   6               0.173              9.680           35.570             45.250     -20.093     65.343   QUASIPEAK
   7               0.173              9.680           27.000             36.680     -28.663     65.343      AVERAGE
   8               0.189              9.680           37.500             47.180     -17.706     64.886   QUASIPEAK
   9               0.189              9.680           27.390             37.070     -27.816     64.886      AVERAGE
  10               0.259              9.680           26.490             36.170     -26.716     62.886   QUASIPEAK
  11               0.259              9.680            9.300             18.980     -43.906     62.886      AVERAGE
  12               4.306              9.814           17.160             26.974     -29.026     56.000   QUASIPEAK
  13               4.306              9.814           16.050             25.864     -30.136     56.000      AVERAGE
  14              19.845           10.405             23.610             34.015     -25.985     60.000   QUASIPEAK
  15              19.845           10.405             23.600             34.005     -25.995     60.000      AVERAGE


Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor.


                                                    Page: 17 of 34


Report No: 1780285R-ITUSP04V00


3.6. Test Photograph
    FCC Part 18
      Test Mode   : Mode 1: Normal Operation (WPT+NFC)
      Description : Front View of Conducted Emission Test Setup




      Test Mode   : Mode 1: Normal Operation (WPT+NFC)
      Description : Back View of Conducted Emission Test Setup




                                        Page: 18 of 34


Report No: 1780285R-ITUSP04V00


    RSS-216
      Test Mode   : Mode 1: Normal Operation (WPT+NFC)
      Description : Front View of Conducted Emission Test Setup




      Test Mode   : Mode 1: Normal Operation (WPT+NFC)
      Description : Back View of Conducted Emission Test Setup




                                        Page: 19 of 34


Report No: 1780285R-ITUSP04V00


4. Radiated Emission

4.1. Test Specification

     According to EMC Standard : FCC Part 18, RSS-216, MP-5, ANSI C63.4

4.2. Test Setup

     FCC Part 18




     RSS-216




                                      Page: 20 of 34


Report No: 1780285R-ITUSP04V00


4.3. Limit
     FCC Part 18
        (a) ISM equipment operating on a frequency specified in §18.301 is permitted unlimited
             radiated energy in the band specified for that frequency:
        §18.301
        ISM frequency      Tolerance     ISM frequency       Tolerance    ISM frequency        Tolerance
           6.78 MHz        ± 15.0 kHz      13.56 MHz         ± 7.0 kHz      27.12 MHz      ± 163.0 kHz
          40.68 MHz        ± 20.0 kHz      915 MHz          ± 13.0 MHz      2,450 MHz      ± 50.0 MHz
          5,800 MHz       ± 75.0 MHz      24,125 MHz        ± 125.0 MHz     61.25 GHz     ± 250.0 MHz
          122.50 GHz      ± 500.0 MHz     245.00 GHz         ± 1.0 GHz
         Remark:      The use of the 6.78 MHz ± 15.0 kHz frequency band is subject to the
                      condition of footnote 524 of the Table of Allocations.


        (b) The field strength level of emissions which lie outside the bands specified in §18.301,
             unless otherwise indicated, shall not exceed the following:
                                                       RF Power
                                                       generated        Field strength limit     Distance
            Equipment         Operating frequency
                                                           by                 (uV/m)             (meters)
                                                       equipment
        Any type unless Any ISM frequency             Below 500 25                                 300
                                                                                                   1
        otherwise                                     500 or more 25*SQRT(power/500)                300
        specified          AnyNon-ISM frequency Below 500 15                                       300
                                                                                                   1
        (miscellaneous).                              500 or more 15*SQRT(power/500)                300
        Industrial heaters
                           ON or below 5.725MHz Any                 10                             1600
        and RF stabilized                                           (2)                                (2)
                           Above 5.725MHz             Any
        arc welders.
        Medical diathermy Any ISM frequency           Any           25                             300
                           Any Non-ISM frequency Any                15                             300
                           Below 490 kHz              Below 500 2400/F(kHz)                        300
                                                                                                   3
        Ultrasonic                                    500 or more 2400/F(kHz)*                      300
                                                                        SQRT(power/500)
                           490 to 1600 kHz            Any           24000/F(kHz)                       30
                           Above 1600 kHz             Any           15                                 30
                                                                                                    4
        Induction cooking Below 90 kHz                 Any           1500                              30
                                                                                                    4
        ranges            On or above 90 kHz           Any           300                               30
        Remark:
                    1. Field strength may not exceed 10 uV/m at 1600 meters. Consumer equipment
                        operating below 1000 MHz is not permitted the increase in field strength
                        otherwise permitted here for power over 500watts.
                    2. Reduced to the greatest extend possible.
                    3. Field strength may not exceed 10 uV/m at 1600 meters. Consumer equipment is
                        not permitted the increase in field strength otherwise permitted here for over
                        500watts.
                    4. Induction cooking ranges manufactured prior to February 1, 1980, shall not be
                        subject to the field strength limits for miscellaneous ISM equipment.

                                           Page: 21 of 34


Report No: 1780285R-ITUSP04V00


        (c) The field strength limits for RF lighting devices shall be the following:

                 Frequency                        Field strength limit at 30 meters (uV/m)
                    MHz                            (uV/m)                        (dBuV/m)
        Non-consumer equipment:
                   30 – 88                           30                             29.5
                  88 – 216                           50                                 34
                 216 – 1000                          70                             36.9
        Consumer equipment:
                   30 – 88                           10                                 20
                  88 – 216                           15                             23.5
                 216 – 1000                          20                                 26


       Note:
       1. The tighter limits shall apply at the boundary between two frequency ranges.
       2. Testing for compliance with these limits may be made at closer distances, provided
          a sufficient number of measurements are taken to plot the radiation pattern, to
          determine the major lobes of radiation, and to determine the expected field strength
          level at 30, 300, or 1600 meters. Alternatively, if measurements are made at only
          one closer fixed distance, then the permissible field strength limits shall be adjusted
          using 1/d as attenuation factor.


     RSS-216




                                             Page: 22 of 34


Report No: 1780285R-ITUSP04V00


4.4. Test Procedure
       FCC Part 18
        The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.
        The turn table can rotate 360 degrees to determine the position of the maximum emission
        level.
        The EUT was positioned such that the distance from antenna to the EUT was 10 meters.
        The antenna can move up and down between 1 meter and 4 meters to find out the
        maximum emission level.
        Both horizontal and vertical polarization of the antenna are set on measurement. In order
        to find the maximum emission, all of the interface cables must be manipulated according
        to ANSI C63.4: 2014 on radiated measurement.
        Radiated emissions were invested over the frequency range from 30MHz to1GHz using a
        receiver bandwidth of 120kHz. Radiated was performed at an antenna to EUT distance of
        3 meters.


       RSS-216
        The magnetic component is measured by means of a loop antenna. The EUT is placed in
        the centre of the antenna. The induced current in the loop antenna is measured by means
        of a current probe (1 V/A) and the measuring receiver.
        Radiated emissions were investigated over the frequency range from 0.009MHz to
        30MHz using a receiver, where the resolution bandwidth of the receiver is set as 200Hz at
        frequency range from 0.009MHz to 0.15MHz and set as 9KHz at frequency range from
        0.15MHz to 30MHz.




                                         Page: 23 of 34


Report No: 1780285R-ITUSP04V00


4.5. Test Result
FCC Part 18
Site : CB1-H                                                    Time : 2017/08/22

Limit : FCC_PART18_03M_QP                                       Margin : 6

Probe : CB1_0208 - HORIZONTAL                                   Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                        Note : Mode 1: Normal Operation (WPT+NFC)




           Frequency       Correct Factor      Reading Level      Measure Level       Margin      Limit      Detector Type
               (MHz)           (dB)               (dBuV)            (dBuV/m)           (dB)      (dBuV/m)

   1              36.929           -18.903             57.000                38.097    -29.803      67.900   QUASIPEAK

   2             189.870           -22.864             60.000                37.136    -30.764      67.900   QUASIPEAK

   3             216.990           -20.354             60.000                39.646    -28.254      67.900   QUASIPEAK

   4   *         404.143           -13.457             58.900                45.443    -22.457      67.900   QUASIPEAK

   5             455.000           -12.328             56.300                43.973    -23.927      67.900   QUASIPEAK

   6             520.000           -12.082             55.600                43.518    -24.382      67.900   QUASIPEAK

   7             550.000           -11.234             54.800                43.566    -24.334      67.900   QUASIPEAK

   8             779.671              -8.961           50.900                41.939    -25.961      67.900   QUASIPEAK



  Note:
     1. All Reading Levels are Quasi-Peak value.
     2. “ * ”, means this data is the worst emission level.
     3. Measurement Level = Reading Level + Correct Factor.




                                                     Page: 24 of 34


Report No: 1780285R-ITUSP04V00




Site : CB1-H                                                    Time : 2017/08/22

Limit : FCC_PART18_03M_QP                                       Margin : 6

Probe : CB1_0208 - VERTICAL                                     Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                        Note : Mode 1: Normal Operation (WPT+NFC)




           Frequency       Correct Factor      Reading Level      Measure Level       Margin      Limit      Detector Type

               (MHz)           (dB)               (dBuV)            (dBuV/m)           (dB)      (dBuV/m)

   1              42.471           -17.839             53.400                35.562    -32.338      67.900   QUASIPEAK

   2              54.280           -23.634             61.500                37.866    -30.034      67.900   QUASIPEAK

   3              81.271           -18.951             57.400                38.450    -29.450      67.900   QUASIPEAK

   4             107.600           -18.469             56.000                37.531    -30.369      67.900   QUASIPEAK

   5   *         189.840           -17.496             60.300                42.804    -25.096      67.900   QUASIPEAK

   6   *         217.000           -17.080             60.200                43.120    -24.780      67.900   QUASIPEAK

   7             519.157           -13.992             54.200                40.208    -27.692      67.900   QUASIPEAK

   8             671.586           -11.116             53.200                42.084    -25.816      67.900   QUASIPEAK

   9             678.514           -11.085             52.400                41.315    -26.585      67.900   QUASIPEAK

  10             733.943              -7.975           47.600                39.626    -28.274      67.900   QUASIPEAK


  Note:
     1. All Reading Levels are Quasi-Peak value.
     2. “ * ”, means this data is the worst emission level.
     3. Measurement Level = Reading Level + Correct Factor.




                                                     Page: 25 of 34


Report No: 1780285R-ITUSP04V00


RSS-216
Site : SR2-H                                                   Time : 2017/10/27

Limit : CNS_13803_2M_H_RE_00M_QP                               Margin : 0

Probe :    - HORIZONTAL                                        Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                       Note : Mode 1: Normal Operation (WPT+NFC)




           Frequency       Correct Factor     Reading Level      Measure Level       Margin      Limit      Detector Type
               (MHz)           (dB)              (dBuA)            (dBuA/m)           (dB)      (dBuA/m)
   1               0.047              0.000           15.680                15.680    -72.320      88.000   QUASIPEAK
   2               0.094              0.000            7.720                 7.720    -71.049      78.769   QUASIPEAK
   3               0.130              0.058           31.070                31.128    -33.795      64.923   QUASIPEAK
   4               0.150              0.086           11.930                12.016    -45.982      57.998   QUASIPEAK
   5               0.396              0.100           11.180                11.280    -46.421      57.701   QUASIPEAK
   6               0.443              0.100            9.450                 9.550    -48.094      57.644   QUASIPEAK
   7   *          22.474              0.600            8.330                 8.930    -22.146      31.076   QUASIPEAK


  Note:
     1. All Reading Levels are Quasi-Peak value.
     2. “ * ”, means this data is the worst emission level.
     3. Measurement Level = Reading Level + Correct Factor.




                                                    Page: 26 of 34


Report No: 1780285R-ITUSP04V00




Site : SR2-H                                                   Time : 2017/10/27

Limit : CNS_13803_2M_V_RE_00M_QP                               Margin : 0

Probe :    - VERTICAL                                          Power : AC 120V/60Hz

EUT : WIRELESS POWER TRANSMISSION SYSTEM                       Note : Mode 1: Normal Operation (WPT+NFC)




           Frequency       Correct Factor     Reading Level      Measure Level       Margin      Limit      Detector Type
               (MHz)           (dB)              (dBuA)            (dBuA/m)           (dB)      (dBuA/m)

   1               0.047              0.000           14.730                14.730    -91.270    106.000    QUASIPEAK

   2               0.084              0.000            5.000                 5.000    -95.615    100.615    QUASIPEAK

   3   *           0.130              0.058           52.260                52.318    -30.605      82.923   QUASIPEAK

   4               0.248              0.100           12.950                13.050    -62.829      75.879   QUASIPEAK

   5               0.392              0.100           26.060                26.160    -49.546      75.706   QUASIPEAK

   6               0.650              0.130           14.670                14.800    -60.595      75.395   QUASIPEAK


  Note:
     1. All Reading Levels are Quasi-Peak value.
     2. “ * ”, means this data is the worst emission level.
     3. Measurement Level = Reading Level + Correct Factor.




                                                    Page: 27 of 34



Document Created: 2017-10-31 09:16:42
Document Modified: 2017-10-31 09:16:42

© 2024 FCC.report