Test report Bluetooth LE - FCC report

FCC ID: U4GFX4WB

Test Report

Download: PDF
FCCID_3768877

                                        PARTIAL T E S T R E P O R T
                                          No.: 17-1-0180901T11a


                                                                According to:

                                                             FCC Regulations
                                                               Part 15.205
                                                               Part 15.209
                                                               Part 15.247



                                                                 for

                                                      Datalogic S.r.l.


                                            FALCON X4
                                     Type: E00ANM4HS0GF0A4
                                                     FCC ID: U4GFX4WB


                                             Laboratory Accreditation and Listings




                                                                                                      Voluntary Controls for
                                                                               Industry Canada      Electromagnetic Emissions
                                                                              Reg. No.: 3462D-1             Reg. No.:
                                                       MRA US-EU 0003         Reg. No.: 3462D-2          R-2666 C-2914,
                                                                              Reg. No.: 3462D-3          T-1967, G-301




                                       accredited according to DIN EN ISO/IEC 17025
                                                     CETECOM GmbH
                                Laboratory Radio Communications & Electromagnetic Compatibility
                                            Im Teelbruch 116 • 45219 Essen • Germany
                                   Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                     E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                              Page 1 of 31
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written
approval of the testing laboratory                                                  © Copyright: All rights reserved by CETECOM


Test Report 17-1-0180901T11a, Page 2 of 31


Table of contents
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. Tests measurement overview according to FCC Standard .............................................................................. 3
2. ADMINISTRATIVE DATA ............................................................................................................................... 5
  2.1. Identification of the testing laboratory ............................................................................................................. 5
  2.2. Test location .................................................................................................................................................... 5
  2.3. Organizational items ........................................................................................................................................ 5
  2.4. Applicant’s details ........................................................................................................................................... 5
  2.5. Manufacturer’s details ..................................................................................................................................... 5
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 6
  3.1. Certification Data of Main EUT declared by Applicant .................................................................................. 6
  3.2. Bluetooth LE Technical Data of Main EUT as Declared by Applicant ........................................................... 7
  3.3. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 8
  3.4. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 8
  3.5. EUT set-ups ..................................................................................................................................................... 8
  3.6. EUT operating modes ...................................................................................................................................... 9
  3.7. Configuration of cables used for testing .......................................................................................................... 9
4. DESCRIPTION OF TEST SYSTEM SET-UP’S .............................................................................................. 10
  4.1. Test system set-up for conducted measurements on antenna port ................................................................... 10
  4.2. Test system set-up for radiated magnetic field measurements below 30 MHz ................................................ 11
  4.3. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz ............................................... 12
  4.4. Test system set-up for radiated electric field measurement above 1 GHz ....................................................... 13
5. MEASUREMENTS ............................................................................................................................................. 14
  5.1. Duty-Cycle....................................................................................................................................................... 14
  5.2. RF-Parameter – RF Power conducted.............................................................................................................. 16
  5.3. General Limit - Radiated field strength emissions below 30 MHz .................................................................. 18
  5.4. General Limit - Radiated field strength emissions. 30 MHz - 1 GHz .............................................................. 20
  5.5. General Limit - Radiated emissions. above 1 GHz .......................................................................................... 22
  5.6. RF-Parameter - Radiated Band Edge compliance measurements .................................................................... 24
  5.7. Measurement uncertainties .............................................................................................................................. 26
6. ABBREVIATIONS USED IN THIS REPORT ................................................................................................. 27
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 27
8. INSTRUMENTS AND ANCILLARY ................................................................................................................ 28
  TC” ......................................................................................................................................................................... 28
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................. 31


                                                                    Table of Annex
  Annex No.                      Contents                            Reference Description                                                              Total Pages
   Annex 1                      Test results               CETECOM_TR17-1-0180901T11a-A1                                                                    20
   Annex 2             External photographs of EUT         CETECOM_TR17-1-0180901T11a-A2                                                                     9
   Annex 2             Internal photographs of EUT         CETECOM_TR17-1-0180901T11a-A3                                                                    12
   Annex 4                Test set-up photographs          CETECOM_TR17-1-0180901T11a-A4                                                                    10
                                    The listed attachments are an integral part of this report.




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 3 of 31



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.


The test results apply exclusively to the test samples as presented in this report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveillance tests.

The presented Equipment Under Test(in this report, hereinafter referred as EUT) : FALCON X4 integrates total
1 of pre-certified module WL18MODGI (FCC ID: Z64-WL18DBMOD) & supports following technologies :

EUT supported Technologies which are not tested within this test report

              EUT supported Technology                                           Test Report Reference
 Bluetooth FHSS (BR-EDR) Modes: 2402 – 2480 MHz                              CETECOM_TR17-1-0180901T10a
 WLAN 802.11b/g/n(HT20) Modes: 2412 – 2462 MHz                               CETECOM_TR17-1-0180901T12a
 WLAN 802.11a/n(HT20)/n(HT40)Modes: 5150–5850 MHz                            CETECOM_TR17-1-0180901T16a
 AC Power Lines - Internal Battery Charging                                  CETECOM_TR17-1-0180901T18a

EUT supported Technologies which are tested within this test report
 - 2.4 GHz Bluetooth Low Energy Modes : 2402 – 2480 MHz

Following test cases have been performed to show compliance with valid Part 15.205/15.209/15.247 of the FCC
CFR Title 47 Rules, Edition 4th November 2016.

1.1. Tests measurement overview according to FCC Standard
                                                  References and Limits                          EUT
                                                                                         EUT
    Test cases               Port                                                                 op.    Result
                                          FCC Standard               Test limit         set-up
                                                                                                 mode
                                                           TX-Mode
       6 dB            Antenna terminal
                                          §15.247 (a) (2)       At least 500 kHz          --      --    Remark 2)
     bandwidth           (conducted)

   99% occupied        Antenna terminal
                                             2.1049(h)        99% Power bandwidth         --      --    Remark 2)
    bandwidth            (conducted)

  Transmitter Peak     Antenna terminal
                                          §15.247 (b) (3)              <1W                2       1       Pass
    output power         (conducted)

   Power Spectral      Antenna terminal
                                             §15.247 (e)      < 8 dBm in 3 kHz band       --      --    Remark 2)
      Density            (conducted)
                                                                 Operation within
     Transmitter       Antenna terminal
                                                 --           designated operational      --      --    Not tested
 frequency stability     (conducted)
                                                                       band
  Transmitter Peak                                              < 1 W for antenna
                          Enclosure
    output power                          §15.247 (b) (3)      with directional gain      --      --    Remark 2)
                          (radiated)
      radiated                                                   less than 6 dBi.
                                                                20 dBc Conducted
 Out-Of-Band RF-       Antenna terminal
                                             §15.247 (d)      Emissions in restricted     --      --    Remark 2)
    emissions            (conducted)
                                                                       bands




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 4 of 31

                                                                              Emissions in restricted
       Band-Edge                        Enclosure                              bands must meet the
                                                                §15.247 (d)                                    1               1                   Pass
       emissions                        (radiated)                             general field strength
                                                                                  radiated limits

     General field                   Enclosure +                              Emissions in restricted
                                                                §15.247 (d)
  strength emissions               Interconnecting                             bands must meet the
                                                                 §15.205                                       1               1                   Pass
      + restricted                      cables                                general field-strength
                                                                 §15.209
         bands                        (radiated)                                  radiated limits


   AC-Power Lines                  AC-Power lines
                                                                                  AC Power line
     Conducted                            or                    §15.207(a)                                     --              --             Remark 1)
                                                                                 conducted limits
     Emissions                     Battery Charger

Remark 1) : Not tested in this report as Bluetooth test configuration was operated using fully charged internal battery
Refer separate report CETECOM_TR17-1-0180901T18a
Remark 2): Refer WL18MODGI (FCC ID: Z64-WL18DBMOD) Report No. FR4O0971B, Rev.01, issue date Dec 19,2014




                                                  Specific Absorption Rate (SAR) Measurements
                                          (separation distance user to RF-radiating element within 20cm)
                                                                   References & Limits                                          EUT
                                                                                                                    EUT
    Test cases                    Port                                                                                           op.               Result
                                                           FCC Standard               Test Limit                   set-up
                                                                                                                                mode
                                                                                Specific Absorption
                                                              §2.1091
                                                                                   Rate (SAR) for
                              Cabinet                         §2.1093
                                                                                 Devices Used by the
    Specific                     +                                                                                                            Refer separate
                                                                                   General Public
   Absorption                  Inter-                            +                                                                                report
                                                                                   (Uncontrolled                     --             --      CETECOM_TR17-
   Rate (SAR)                connecting                    IEEE 1528-2013
                                                                                   Environment)                                              1-0180901T09a
  requirements                 cables                            +
                                                                                    : 1.6 W/Kg as
                               (radiated)                KDB 865664D01v0r04
                                                                                averaged over any 1 g
                                                                                         tissue




......................................................                                                  ....................................................
Dipl.-Ing. Niels Jeß                                                                                                        M.Sc. Ajit Phadtare
Responsible for test section                                                                                      Responsible for test report




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 5 of 31


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report and
Project leader:                                                       M.Sc. Ajit Phadtare
Receipt of EUT:                                                       2017-10-20
Date(s) of test:                                                      2017-10-12 to 2017-12-25
Date of report:                                                       2017-12-27
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     Datalogic S.r.l.
Address:                                                              Via S. Vitalino, 13
                                                                      40012, Lippo di Calderara di Reno (BO)
                                                                      ITALY

Contact:                                                              Mr. Francesco Rossi

2.5. Manufacturer’s details

Manufacturer’s name:                                                  same as Applicant

Address:                                                              same as Applicant




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 6 of 31


3. Equipment under test (EUT)
3.1. Certification Data of Main EUT declared by Applicant


EUT Model                           FALCON X4
EUT Model Type                      E00ANM4HS0GF0A4
EUT Type                            Portable Mobile Computer
EUT Applications                    Shopping Applications & General Purpose Mobile Computer
FCC ID                              U4GFX4WB
                                  Additional Information: Integrated Module
Integrated Module                   WL18MODGI
Module Certification FCC ID         Z64-WL18DBMOD
Number of Integrated Modules 1
                                Additional Information : Supported Technologies
Technology                          Modes                   Frequency Range               Remarks
Bluetooth LE                 Bluetooth Low Energy        2402 MHz – 2480 MHz           refer chapter 3.2
Bluetooth FHSS                Bluetooth BR-EDR           2402 MHz – 2480 MHz not tested under this report
WLAN 2.4 GHz            WLAN 802.11b/g/n(HT20)           2412 MHz – 2462 MHz not tested under this report
WLAN 5 GHz          WLAN 802.11a/n(HT20)/n(HT40)         5150 MHz –5850 MHz       not tested under this report




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 7 of 31

3.2. Bluetooth LE Technical Data of Main EUT as Declared by Applicant


EUT Model                      FALCON X4
EUT Model Type                 E00ANM4HS0GF0A4
EUT Type                       Portable Mobile Computer
EUT Applications               Shopping applications & general purpose mobile computer
Hardware Version               BETA
Software Version               Android 4.4.4
Firmware Version               2.01.46.20180109
Frequency Band                 2.4 GHz ISM Band (2400 MHz - 2483.5 MHz)
Frequency Channels (Range)     Channel 37: 2402 MHz to Channel 39: 2480 MHz
Number of Channels             40 (37 Hopping + 3 Advertising)
Channels Power Settings         +7 dBm (According to Applicant’s Declaration Max. Rated Power Values)
Nominal Channel Bandwidth      1 MHz
Type of DSSS Mode              Low Energy (LE) Mode :
Modulation | Data Rate           BT 4.0: GFSK | 1 Mbps
Antenna Details                Integrated (ANT1 & ANT2)
Antenna Connections            Primary Antenna : ANT1 (BT LE)                Secondary Antenna: ANT2 not used
Antenna Type                   Laird PCBA Antenna
ANT1 Gain (Peak)               3.04 dBi (2400 MHz – 2500 MHz) (According to Applicant’s Declaration)
ANT2 Gain (Peak)               2.80 dBi (2400 MHz – 2500 MHz) (According to Applicant’s Declaration)
Total Number of Modules        1 (WL18MODGI Module FCC ID: Z64-WL18DBMOD)
Total Number of Antennas       2     Primary Antenna : ANT1 (BT LE)             Secondary Antenna: ANT2 not used
Test Mode Settings              Datalogic RFTest Application
MAX Field Strength                                                 Average Value: 97.392 dBµV/m
                               Peak Value : 98.058 dBµV/m
(Radiated@3m)                                                      with Duty Cycle Correction : 1.99 dB
                                Internal Battery : BT-26 | Li-ion|3.7- 4.2VDC 5200mAh
Power Supply
                                                             (2 Cylindrical Cells)
Special EMI Components         --
EUT Sample Type                 Production              Pre-Production  Engineering
Firmware                        for normal use  Special version for test execution : Datalogic RFTest
FCC label attached              Yes                     No
                For further details refer Applicants Declaration & following technical documents
 Description of Reference Document (supplied by applicant)                     Version                  Total Pages
FALCON X4_Test-Tools_Quick_Start_Instructions                        Rev: 0 Date: 14/09/2017                45
                                                                       822002580 Rev: A
FALCON X4_Quick Start Guide                                                                                 2
                                                                         December 2017
FALCON X4 Hardware Modifications                                         December 2017                      7
Datalogic Falcon FX4 Antenna_Rev E                                   Rev:E Date : 30/10/2017                15




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 8 of 31

3.3. EUT: Type, S/N etc. and short descriptions used in this test report
   Short
                                                                              Serial       Hardware        Software
  Descrip-
                             EUT                        Type                 Number         Status          Status
   tion*)
                                                                                              HW         SW Version:
                                                                                            Version:     Android 4.4.4
                                                                                             BETA
   EUT A               FALCON X4               E00ANM4HS0GF0A4 Z17P02008                                   Firmware
                                                                                             P/N:          Version:
                                                                                          945550001      2.01.46.2018
                                                                                                             0109
                                                                                              HW         SW Version:
                                                                                            Version:     Android 4.4.4
                                                                                             BETA
   EUT B               FALCON X4               E00ANM4HS0GF0A4 Z17P02012                                   Firmware
                                                                                             P/N:          Version:
                                                                                          945550001      2.01.46.2018
                                                                                                             0109
*) EUT short description is used to simplify the identification of the EUT in this test report.


3.4. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
    AE
   short                                                                                                       SW
                                                                     S/N                    HW
 descrip- Auxiliary Equipment                 Type                                                           software
                                                                serial number          hardware status
  tion *)                                                                                                     status

  AE 1                --                        --                    --                      --                 --

*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.


3.5. EUT set-ups

 EUT set-
                 Combination of EUT and AE                                      Description
 up no.*)

   set. 1                    EUT A                                         Radiated measurements


   set. 2        EUT B + Cable 1 + Cable 2                             Conducted measurements

*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 9 of 31

3.6. EUT operating modes

   EUT
                  Description of                                 Additional information
 operating
                 operating modes
mode no.*)
                                       For Bluetooth Low Energy Modes tests are carried out with different
                                       Channels | Modulation | Data Rate Combinations with help of Datalogic
                                       RFTest Application.

                                   The EUT was put to Fixed Channel (Modulated) Continuous
                                   transmissions mode | Pattern Length : 37 | PRBS9 with help of
              Bluetooth Low Energy
                                   Datalogic RFTest Application.
                     Modes*
    op. 1
                                       (Channel Type | Frequency | Power Settings)
                TX-Fixed Channel
                                       Lowest Channel : 0 : 2402 MHz | Power : +7 dBm
                  (Modulated)
                                       Middle Channel :19: 2440 MHz | Power : +7 dBm
                                       Highest Channel :39: 2480 MHz | Power : +7 dBm

                                       *Other supported wireless technologies were put in idle mode using
                                       special test software


              Bluetooth Low Energy The EUT was put to Fixed Channel (Modulated) Continuous
                     Modes*        receiving mode with help of Datalogic RFTest Application.
    op. 2
                RX-Fixed Channel       *Other supported wireless technologies were put in idle mode using
                  (Modulated)          special test software

*) EUT operating mode no. is used to simplify the test report.


3.7. Configuration of cables used for testing

 Cable number            Description                             Connections                    Cable length

    Cable 1           RF –SMA Cable                     EUT ANT1 to Power Meter                    0.08 m

    Cable 2           RF –SMA Cable                   EUT ANT2 to 50 Ω Termination                 0.08 m




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 10 of 31


4. Description of test system set-up’s
4.1. Test system set-up for conducted measurements on antenna port
                                    Bluetooth conducted RF-Setup 1 (BT1 Set-up)

 General description:           The EUT‘s RF-signal is coupled out by a suitable antenna coupling connector (1). The
                                signal is first attenuated (2) then connected to the power meter (3) for conducted power
                                measurements. The specific attenuation loss is determined prior to the measurement within
                                a set-up attenuation measurement. These are then taken into account by correcting the
                                measurement readings.
 Schematic:




 Testing method:                ANSI C63.10:2013, KDB 558074 D01 DTS Meas.Guidance v04

 Used Equipment                    Passive Elements          Test Equipment         Remark:

                                 20 dB Attenuator        Power Meter              See List of equipment under each test
                                 Low loss RF-cables      DC-Power Supply          case and chapter 8 for calibration
                                                          Spectrum- Analyser       info


 Measurement uncertainty        See chapter 5.7




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 11 of 31

4.2. Test system set-up for radiated magnetic field measurements below 30 MHz


 Specification:              ANSI C63.10-2013 chapter 6.4 (§6.4.4.2)

 General Description:        Evaluating the radiated field emissions are done first by an exploratory emission
                             measurement and a final measurement for most critical frequencies determined.
                             The loop antenna was placed at 1 m height above ground plane and 3 m
                             measurement distance from set-up for investigations. Because of reduced
                             measurement distance, correction data were applied, as stated in chapter “General
                             Limit - Radiated field strength emissions below 30 MHz“. The tests are performed
                             in the semi anechoic room recognized by the regulatory commission.

 Schematic:




 Testing method:             Exploratory, preliminary measurement                 Final measurement on critical frequencies
                             The EUT and it’s associated accessories are          Based on the exploratory measurements, the most
                             placed on a non-conductive position manipulator      critical frequencies are re-measured by main-
                             (tipping device) of 0.8 m height which is placed     taining the EUT’s worst-case operation mode,
                             on the turntable. By rotating the turntable (step    cable position, etc.
                             90°, range 0°to 360°) and the EUT itself either on
                             3-orthogonal axis (portable equipment) or 2-         First a frequency zoom around the critical
                             orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                             EUT), the emission spectrum was recorded. The        precisely. After this step, for all identified critical
                             loop antenna was moved at least to                   frequencies, the maximum peak was determined.
                             2-perpendicular axes (antenna vector in direction
                             of EUT and parallel to EUT) in order to maximize     Following parameters were varied: the turntable
                             the emissions. The results are documented in a       angle continuously in the range 0 to 360 degree,
                             diagram. Critical frequencies (low margin to         the EUT itself either over 3-orthogonal axis (not
                             limit) are saved within a data reduction table for   defined usage position) or 2-orthogonal axis
                             further investigations. If various operating modes   (defined usage position).
                             are supported, further investigations are made to
                             find the worst-case. Also the interconnection        On the determined worst-case position, a final
                             cables and equipment position were varied in         measurement with necessary bandwidth and
                             order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                    EC = ER + AF + CL + DF - GA               AF =Antenna factor
                                                                       CL = Cable loss
                             M = LT-EC                                 DF= Distance correction factor
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA= Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.

 Distance correction:
                             Reference for applied correction (extrapolating) factors due to reduced
                             measurement distance:
                             ANSI C63.10:2013, §6.4.4.2 - Equations (2) + (3) + (4)




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 12 of 31

4.3. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz


 Specification:              ANSI C63.4-2014 chapter 8.2.3, ANSI C63.10-2013 chapter 6.5

 General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                             regulatory commissions.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                             turntable. By rotating the turntable (range 0° to    position, etc. either on 10m OATS or 3m semi-
                             360°, step 90°) and the EUT itself either on 3-      anechoic room.
                             orthogonal axis (portable equipment) or 2-
                             orthogonal axis (defined operational position of     First a frequency zoom around the critical frequency
                             EUT) the emission spectrum and it’s                  is done to locate the frequency more precisely. After
                             characteristics was recorded with an EMI-            this step, for all identified critical frequencies, the
                             receiver, broadband antenna and software.            maximum peak was determined.

                             Measurement antenna: horizontal and vertical,        Following parameters were varied: the turntable
                             heights: 1,0 m and 1,82 m as worst-case              angle continuously in the range 0 to 360 degree, the
                             determined by an exploratory emission                EUT itself either over 3-orthogonal axis (not
                             measurements. The results are documented in a        defined usage position) or 2-orthogonal axis
                             diagram. Critical frequencies (low margin to         (defined usage position). The measurement antenna
                             limit) are saved within a table for further          height between 1 m and 4 m.
                             investigations. If various operating modes are
                             supported, further investigations are made to find   On the determined worst-case position, a final
                             the worst-case of them. Also the interconnection     measurement with necessary bandwidth and
                             cables and equipment position were varied in         detector according standard has been carried out.
                             order to maximize the emissions.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                       CL = Cable loss
                             M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA = Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 13 of 31

4.4. Test system set-up for radiated electric field measurement above 1 GHz


 Specification:              ANSI C63.4-2014 chapter 8.3, ANSI C63.10-2013 chapter 6.6.3.3 & 6.6.4

 General Description:        Evaluating the emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a CISPR 16-1-4:2010 compliant fully anechoic room (FAR)
                             recognized by the regulatory commission. The measurement distance was set to 3
                             meter for frequencies up to 18 GHz and 2 meter above 18 GHz. A logarithmic
                             periodic antenna is used for the frequency range 30 MHz to 1 GHz. Horn antennas
                             are used for frequency range 1 GHz to 40 GHz. The EUT is aligned within 3 dB
                             beam width of the measurement antenna with three orthogonal axis measurements
                             on the EUT.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 1.55 m height which is placed on the      taining the EUT’s worst-case operation mode,
                             turntable. By rotating the turntable (range 0° to    cable position, etc.
                             360°, step 15°) and the EUT itself either on 3-
                             orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical
                             orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                             EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                             characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                             receiver, broadband antenna and software.            Following parameters were varied: the turntable
                             The measurements are performed in horizontal         angle continuously in the range 0 to 360 degree,
                             and vertical polarization of the measurement         the EUT itself over 3-orthogonal axis and the
                             antennas. The results are documented in a            height for EUT with large dimensions.
                             diagram. Critical frequencies (low margin to
                             limit) are saved within a table for further          On the determined worst-case position, a final
                             investigations. If various operating modes are       measurement with necessary bandwidth and
                             supported, further investigations are made to find   detector according standard has been carried out.
                             the worst-case of them. Also the interconnection     On the determined worst-case position, a final
                             cables and equipment position were varied in         measurement with necessary bandwidth and
                             order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                             M = LT - EC         (2)                   M = Margin
                                                                       LT = Limit
                                                                       AF = Antenna factor
                                                                       CL = Cable loss
                                                                       DF = Distance correction factor (if used)
                                                                       GA = Gain of pre-amplifier (if used)
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR17-1-0180901T11a


 Test Report 17-1-0180901T11a, Page 14 of 31


 5. Measurements
 5.1. Duty-Cycle
 5.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
Ambient Climatic conditions                Temperature: (22±2)°C     Rel. humidity: (45±15)%
Test Site        441 EMI SAR  348 EMI cond.  443 EMI FAR  347 Radio.lab.                 337 OATS     
Equipment        331 HC 4055                                                                          
Spectr. Analys.  683 FSU26         120 FSEM        264 FSEK        693 TS8997                         
Power Meter      262 NRV-S         266 NRV-Z31  265 NRV-Z33  261 NRV-Z55                 356 NRV-Z1   
Multimeter       341 Fluke 112                                                                        
DC Power         086 LNG50-10  087 EA3013          354 NGPE 40  349 car battery  350 Car battery       463 HP3245A
Supply Voltage  230 V 50 Hz via public mains       4.20 V DC (fully charged internal battery)
Otherwise               Attenuator
                 530               K4 Cable
                        10dB

 Method of measurement:                  conducted
                                         radiated

 A special firmware program is used for test purposes. In contrast to normal operating mode a higher duty-
 cycle is set in order to facilitate the measurements. This is maximized at the extent possible.

 The necessary duty-cycle correction factor is determined on nominal conditions on 1 channel for all sub-bands. It
 is assumed that no noticeable changes occur when tested on other channels or climatic conditions.
 Calculated with following formulas:


                                        x
                                                Txon                                                         1
          Duty cycle:                                                     Duty cycle factor [dB]:      10 log 
                                             Txon  Txoff                                                    x




 CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 15 of 31

Results:

  Set-up No.:                                                                         2
  Op. Mode:                                                                           1


                                                 DUTY-CYCLE Measurement
                                                               TX ON        TX OFF                        Correction-
 BT-LE GFSK      Marker 1        Marker 2      Marker 3       Marker 2 -    Marker 3 -      Duty Cycle      Factor:      Plot No.
                                                              Marker 1      Marker 2                     100log(1/DC)

   Data Rate         ms             ms             ms             ms            ms              (%)          (dB)       (Remark 1)

                                        BT-LEMode| B.W. 1 MHz | SISO | Ch 19 (2440 MHz) | 7 dBm
     1MBit            0,669872       1,067308       1,298077    0,39744        0,23077          63,27        1,99           1



 Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1

 The results were corrected in order to evaluate for worst-case result each time when average values are
  necessary for example average radiated emissions or similar
 No correction necessary: Duty-Cycle > 98%




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 16 of 31

5.2. RF-Parameter – RF Power conducted
5.2.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location       CETECOM Essen (Chapter. 2.2.1)    443 System CTC-FAR-EMI-               Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA         337 OATS          347 Radio.lab.                       
 receiver           377 ESCS30        001 ESS        683 FSU 26                                             
 spectr. analys.    489 ESU           120 FSEM       264 FSEK                                               
 power supply       456 EA 3013A  457 EA 3013A       459 EA 2032-50  4.20 V DC (fully charged internal battery)
 otherwise          613 20dB Attenuator                                  Directional Coupler 1539R-10
Power meter         600 NRVD Power meter                                 266 NRV-Z31 Peak Power Sensor
 Supply voltage     230 V 50 Hz via public mains                        



5.2.2. Requirements:

 FCC                          §15.247 (b) (3) + KDB 558074 D01 DTS Meas.Guidance v04

 ANSI                         C63.10-2013 Chapter 6.101



5.2.3. Reference: EUT antenna characteristics:
 Directional Gain < 6 dBi (measured: difference between measured conducted and radiated eirp. power)
 Directional Gain > 6 dBi (measured / applicant’s declaration) -> conducted power reduction necessary

5.2.4. EUT settings:
For FHHS-systems hopping mode was switched-off so fixed three different channels could be measured. The EUT
was instructed to send with maximum power (if adjustable) according applicants instructions. Different modulation
characteristics have been checked, e.g. data rates which EUT can operate.


5.2.5. Measurement method:
The measurement was performed in non-hopping transmission mode with the carrier set to lowest/middle and
highest channel. The power was also checked for different data rates, modulation scheme or packet types if
applicable.


5.2.6. Settings on Spectrum-Analyzer:
 Center Frequency                       Nominal channel frequency
 Span                                   8 MHz
 Resolution Bandwidth (RBW)             3 MHz > 20dB-Bandwidth of the signal
 Video Bandwidth (VBW)                  3 times the resolution bandwidth = 10MHz
 Sweep time                             coupled
 Detector                               Peak, Max hold mode
 Sweep Mode                             Repetitive mode




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 17 of 31

5.2.7. Conducted measurement: Max. Peak Power

    Applicant’s declared Maximum Directional ANT1 Peak Gain : 3.04 dBi



                                Conducted Max Peak Power Measurements [dBm]

    Set-up no.:    2                    Low channel = 0      Middle channel = 19        High channel = 78
    Op-Mode:       1                      (2402 MHz)            (2440 MHz)                (2480 MHz)
          Bluetooth LE Mode
             GFSK| 1 Mbps                     0.12                   0.29                        0.39
       Pattern Length:37 | PRBS9

    Remark : Measurements results are only valid and compliant with power setting: +7 dBm

    Maximum Conducted value                       0.39 dBm                            0.00109 W

    Maximum antenna ANT1 gain                                        3.04 dBi

    Maximum e.i.r.p. value                        3.43 dBm                            0.00220 W

    FCC 15.247 Limit                             30.00 dBm                                  1W




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 18 of 31

5.3. General Limit - Radiated field strength emissions below 30 MHz
5.3.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)       Please see Chapter. 2.2.2                  Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA            347 Radio.lab.                                             
 receiver           377 ESCS30        001 ESS                                                                     
 spectr. analys.    584 FSU           120 FSEM          264 FSEK                                                  
 antenna            574 BTA-L         021 EMCO6502      302 BBHA9170  289 CBL 6141                030 HFH-Z2  477 GPS
 signaling          392 MT8820A  371 CBT32              547 CMU           594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E        110 USB LWL  482 Filter Matrix            378 RadiSense
 DC power           671 EA-3013S  457 EA 3013A          459 EA 2032-50  268 EA- 3050              494 AG6632A  498 NGPE 40
 Supply voltage     230 V 50 Hz via public mains         4.2 V DC (fully charged internal battery)



5.3.2. Requirements
         FCC             Part 15. Subpart C. §15.205 & §15.209                    Part 15.247 (d)
         ANSI           C63.10-2013
      Frequency                    Field strength limit           Distance
                                                                                                           Remarks
        [MHz]              [μV/m]                [dBμV/m]           [m]
    0.009 – 0.490         2400/f (kHz)    67.6 – 20Log(f) (kHz)     300        Correction factor used due to measurement distance of 3 m
    0.490 – 1.705        24000/f (kHz)    87.6 – 20Log(f) (kHz)      30        Correction factor used due to measurement distance of 3 m
      1.705 – 30               30                 29.5               30        Correction factor used due to measurement distance of 3 m



5.3.3. Test condition and test set-up
 Signal link to test system (if used):      air link      cable connection        none
 EUT-grounding                              none          with power supply  additional connection
 Equipment set up                           table top                              floor standing
 Climatic conditions                       Temperature: (22±3°C)                   Rel. humidity: (40±20)%
                                            9 – 150 kHz             RBW/VBW = 200 Hz           Scan step = 80 Hz
                      Scan data             150 kHz – 30 MHz RBW/VBW = 9 kHz                   Scan step = 4 kHz
                                            other:
 EMI-Receiver or Scan-Mode                  6 dB EMI-Receiver Mode  3dB Spectrum analyser Mode
 Analyzer Settings Detector                Peak (pre-measurement) and Quasi-PK/Average (final if applicable)
                   Mode:                   Repetitive-Scan. max-hold
                   Sweep-Time              Coupled – calibrated display if continuous signal otherwise adapted to EUT’s individual
                                           transmission duty-cycle
General measurement procedures             Please see chapter “Test system set-up radiated magnetic field measurements below 30 MHz”

5.3.4. Radiated Field Strength Emissions – 9 kHz to 30 MHz Results




                   Radiated Field Strength Emissions – 9 kHz to 30 MHz
  Temperature :+21 °C                      Technology: Bluetooth LE Modes                         TX-Fixed Channel (Modulated)
   Diagram                                                                                 Set-   OP-           Used detector
                                            Test Settings
     No.                                                                                    up    mode                             Verdict
   (Remark 1)            Modulation | Data Rate| Pattern Details | Test Channel
                                                                                           no.     no.         PK     AV    QP
                             GFSK | 1 Mbps | Pattern Length:37 | PRBS9
     2.54                                                                                   1          1                            Pass
                                    Lowest Channel 0: 2402 MHz
                             GFSK | 1 Mbps | Pattern Length:37 | PRBS9
     2.55                                                                                   1          1                            Pass
                                    Middle Channel 19: 2440 MHz
                             GFSK | 1 Mbps | Pattern Length:37 | PRBS9
     2.56                                                                                   1          1                            Pass
                                   Highest Channel 39: 2480 MHz

 Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1
 Remark 2: Measurements results are only valid and compliant with power setting: +7 dBm




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 19 of 31

5.3.5. Correction factors due to reduced meas. distance (f< 30 MHz)

The used correction factors when the measurement distance is reduced compared to regulatory measurement
distance. are calculated according Extrapolation formulas valid for EUT’s with maximum dimension of
0.625xLambda. Formula 2+3+4 as presented in ANSI C63.10. Chapter 6.4.4 are used for the calculations of
proper extrapolation factors.




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 20 of 31

5.4. General Limit - Radiated field strength emissions. 30 MHz - 1 GHz
5.4.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)         Please see Chapter. 2.2.2             Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA
 receiver           377 ESCS30        001 ESS             489 ESU 40        620 ESU 26
 spectr. analys.    584 FSU           120 FSEM            264 FSEK
 antenna            574 BTA-L         133 EMCO3115        302 BBHA9170  289 CBL 6141              030 HFH-Z2  477 GPS
 signaling          392 MT8820A  371 CBT32                547 CMU           594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E          110 USB LWL  482 Filter Matrix
 DC power           671 EA-3013S  457 EA 3013A            459 EA 2032-50  268 EA- 3050            494 AG6632A  498 NGPE
 Supply voltage     230 V 50 Hz via public mains           4.2 V DC (fully charged internal battery)



5.4.2. Requirements/Limits
                                              Part 15 Subpart B. §15.109. class B
                     FCC                      Part 15 Subpart C. §15.209 @ frequencies defined in §15.205
                                              Part 15.247 (d)

                                              C63.4-2014
                     ANSI
                                              C63.10-2013
                                                                     Radiated emissions limits. 3 meters
                      Frequency [MHz]
                                                       QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                           30 - 88                           100                                         40.0
     Limit
                          88 - 216                           150                                         43.5
                         216 - 960                           200                                         46.0
                         above 960                           500                                         54.0



5.4.3. Restricted bands of operation (FCC §15.205)
               MHz                               MHz                                     MHz                          GHz
  0.090-0.110                        16.42-16.423                       399.9-410                       4.5-5.15
  0.495-0.505                        16.69475-16.69525                  608-614                         5.35-5.46
  2.1735-2.1905                      16.80425-16.80475                  960-1240                        7.25-7.75
  4.125-4.128                        25.5-25.67                         1300-1427                       8.025-8.5
  4.20725-4.20775                    37.5-38.25                         1645.5-1646.5                   9.3-9.5
  6.215-6.218                        73-74.6                            1660-1710                       10.6-12.7
  6.26775-6.26825                    74.8-75.2                          1718.8-1722.2                   13.25-13.4
  6.31175-6.31225                    108-121.94                         2200-2300                       14.47-14.5
  8.291-8.294                        123-138                            2310-2390                       15.35-16.2
  8.362-8.366                        149.9-150.05                       2483.5-2500                     17.7-21.4
  8.37625-8.38675                    156.52475-156.52525                2690-2900                       22.01-23.12
  8.41425-8.41475                    156.7-156.9                        3260-3267                       23.6-24.0
  12.29-12.293                       162.0125-167.17                    3332-3339                       31.2-31.8
  12.51975-12.52025                  167.72-173.2                       3345.8-3358                     36.43-36.5
  12.57675-12.57725                  240-285                            3600-4400                       --
  13.36-13.41                        322-335.4                          --                              --




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 21 of 31

5.4.4. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan. max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
 General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”



5.4.5. Radiated Field Strength Emissions – 30 MHz to 1 GHz Results




                Radiated Field Strength Emissions – 30 MHz to 1 GHz
  Temperature :+21 °C                         Technology: Bluetooth LE Modes                          TX-Fixed Channel (Modulated)
  Diagram                                                                                      Set-    OP-          Used detector
                                          Test Settings
    No.                                                                                         up     mode                                Verdict
  (Remark 1)           Modulation | Data Rate| Pattern Details | Test Channel
                                                                                               no.      no.        PK      AV     QP
                           GFSK | 1 Mbps | Pattern Length:37 | PRBS9
     3.54                                                                                        1        1                              Pass
                                  Lowest Channel 0: 2402 MHz
                           GFSK | 1 Mbps | Pattern Length:37 | PRBS9
     3.55                                                                                        1        1                              Pass
                                  Middle Channel 19: 2440 MHz
                           GFSK | 1 Mbps | Pattern Length:37 | PRBS9
     3.56                                                                                        1        1                              Pass
                                 Highest Channel 39: 2480 MHz

 Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1
 Remark 2: Measurements results are only valid and compliant with power setting: +7 dBm




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 22 of 31

5.5. General Limit - Radiated emissions. above 1 GHz
5.5.1. Test location and equipment FAR
 test site          441   EMI SAR        348   EMI cond.    443   EMI FAR      347  Radio.lab.  337 OATS             
 spectr. analys.    584   FSU            120   FSEM         264   FSEK         489  ESU 40                           
 antenna meas       574   BTA-L          289   CBL 6141     608   HL 562       549  HL025        302 BBHA9170         477 GPS
 antenna meas       123   HUF-Z2         132   HUF-Z3       030   HFH-Z2       376  BBHA9120E                         
 antenna subst      071   HUF-Z2         020   EMCO3115     063   LP 3146      303  BBHA9170                          
 multimeter         341   Fluke 112                                                                                  
 signaling          392   MT8820A        371   CBT32        547  CMU           594  CMW
 DCpower                                                                                car
                    611 E3632A           087 EA3013         354 NGPE 40  349                     350 Car battery     
                                                                                        battery
Supply voltage  230 V 50 Hz via public mains                 4.2 V DC (fully charged internal battery)



5.5.2. Requirements/Limits (CLASS B equipment)

                             Part 15 Subpart B. §15.109 class B
          FCC                Part 15 Subpart C. §15.209 for frequencies defined in §15.205
                             Part 15.247 (d)


                             C63.4-2014
         ANSI
                             C63.10-2013
                                                                                  Limits
       Frequency                         AV                             AV                         Peak                      Peak
         [MHz]                         [µV/m]                        [dBµV/m]                     [µV/m]                  [dBµV/m] or
                                                                                                                          [dBm/MHz]
    RSS-Gen.. Issue
                                         500                           54.0                        5000                   74.0 dBµV/m
   4. §8.10 - Table 6



5.5.3. Test condition and measurement test set-up
 Signal link to test system (if used):            air link      cable connection       none
 EUT-grounding                                    none          with power supply  additional connection
 Equipment set up                                 table top 1.5m height                 floor standing
 Climatic conditions                             Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan frequency range:                   1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer      Scan-Mode                           6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                           Peak and Average
              RBW/VBW                            1 MHz / 3 MHz
              Mode:                              Repetitive-Scan. max-hold
              Scan step                          400 kHz
              Sweep-Time                         Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
General measurement procedures                   Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 23 of 31

5.5.4. Radiated Field Strength Emissions – 1 GHz to 18 GHz Results




               Radiated Field Strength Emissions – 1 GHz to 18 GHz
  Temperature :+21 °C               Technology: Bluetooth LE Modes                TX-Fixed Channel (Modulated)
  Diagram                                                                  Set-   OP-     Used detector
                                     Test Settings
    No.                                                                     up    mode                     Verdict
  (Remark 1)      Modulation | Data Rate| Pattern Details | Test Channel
                                                                           no.     no.    PK    AV    QP
                     GFSK | 1 Mbps | Pattern Length:37 | PRBS9
    4.54                                                                    1       1                    Pass
                            Lowest Channel 0: 2402 MHz
                     GFSK | 1 Mbps | Pattern Length:37 | PRBS9
    4.55                                                                    1       1                    Pass
                            Middle Channel 19: 2440 MHz
                     GFSK | 1 Mbps | Pattern Length:37 | PRBS9
    4.56                                                                    1       1                    Pass
                           Highest Channel 39: 2480 MHz

 Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1
 Remark 2: Measurements results are only valid and compliant with power setting: +7 dBm



5.5.5. Radiated Field Strength Emissions – 18 GHz to 25 GHz Results




               Radiated Field Strength Emissions – 18 GHz to 25 GHz
  Temperature :+21 °C               Technology: Bluetooth LE Modes                TX-Fixed Channel (Modulated)
  Diagram                                                                  Set-   OP-     Used detector
                                     Test Settings
    No.                                                                     up    mode                     Verdict
  (Remark 1)      Modulation | Data Rate| Pattern Details | Test Channel
                                                                           no.     no.    PK    AV    QP
                     GFSK | 1 Mbps | Pattern Length:37 | PRBS9
    4.54a                                                                   1       1                    Pass
                            Lowest Channel 0: 2402 MHz
                     GFSK | 1 Mbps | Pattern Length:37 | PRBS9
    4.55a                                                                   1       1                    Pass
                            Middle Channel 19: 2440 MHz
                     GFSK | 1 Mbps | Pattern Length:37 | PRBS9
    4.56a                                                                   1       1                    Pass
                           Highest Channel 39: 2480 MHz

 Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1
 Remark 2: Measurements results are only valid and compliant with power setting: +7 dBm




CETECOM_TR17-1-0180901T11a


    Test Report 17-1-0180901T11a, Page 24 of 31

    5.6. RF-Parameter - Radiated Band Edge compliance measurements
5.6.1. Test location and equipment FAR
    test site           441   EMI SAR       348   EMI cond.    443   EMI FAR      347   Radio.lab.  337 OATS        
     spectr. analys.    584   FSU           120   FSEM         264   FSEK         489   ESU 40                      
     antenna meas       574   BTA-L         289   CBL 6141     608   HL 562       549   HL025       302 BBHA9170  477 GPS
     antenna meas       123   HUF-Z2        132   HUF-Z3       030   HFH-Z2       376   BBHA9120E                    
     antenna subst      071   HUF-Z2        020   EMCO3115     063   LP 3146      303   BBHA9170                     
     multimeter         341   Fluke 112                                                                             
     signaling          392   MT8820A       371   CBT32        547   CMU          594   CMW
     DCpower            611   E3632A        087   EA3013       354   NGPE 40      349   carbattery  350 Car battery 
    sSupply
                        230 V 50 Hz via public mains            4.2 V DC (fully charged internal battery)
    voltage

5.6.2. Requirements/Limits
                           Part 15 Subpart B. §15.109 class B
           FCC             Part 15 subpart C. §15.209 @ frequencies defined in §15.205
                           Part 15.247 (d)


           ANSI            C63.4-2009  C63.4-2014  C63.10-2009  C63.10-2013. Chapter 6.10.6



    5.6.3. Test condition and measurement test set-up
     Signal ink to test system (if used):            air link      cable connection       none
     EUT-grounding                                   none          with power supply  additional connection
     Equipment set up                                table top 1.5m height                 floor standing
     Climatic conditions                            Temperature: (22±3°C)                  Rel. humidity: (40±20)%
    Spectrum- Scan frequency range:                  1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other: see diagrams
    Analyzer      Scan-Mode                          6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
    settings      Detector                          Peak and Average
                  RBW/VBW                           Left band-edge: 100kHz/300kHz
                                                    Right band-edge: 1 MHz / 3 MHz
               Mode:                                Repetitive-Scan. max-hold
               Scan step                            40kHz or 400 kHz
               Sweep-Time                           Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
    General measurement procedures                  Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”
                                                    for general measurements procedures in anechoic chamber.

5.6.4. Measurement Method
     For uncritical results where a measurement resolution bandwidth of 1MHz can clearly show the compliance
     without influencing the results. a field strength measurement was performed to show compliance.

    For critical results a Marker-Delta marker method was used for showing compliance to restricted bands. The
    method is according ANSI C63.10:2013. Chapter 6.10.6 “Marker-Delta method”.. The method consists of three
    independent steps:
    1. Step: Prior to the measurement the fundamental radiated In-Band field strength was performed. The determined
             value is used as reference value.
    2. Step: Second step consist of finding the relative attenuation between the fundamental emission and the
             maximum local out-of-band emission (within 2 MHz range around the band edge either on the band-edge
             directly or some modulation product if the level is greater than that on the band-edge) when measured
             with lower resolution bandwidth.
    3. Step: The delta value recorded in step 2 will be subtracted from value recorded in step 1. thus giving the required
             field strength at the band-edge. This value must fulfil the requirements for radiated spurious emissions in
             restricted bands in FCC §15.205 with the general limits of FCC §15.209.

    5.6.5. EUT settings
    The EUT was set in Hopping OFF mode with maximum power (if adjustable) according to applicants instructions.




    CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 25 of 31

5.6.6. Results: for non-restricted bands near-by
5.6.6.1. Non-restricted bands near-by - limits according FCC §15.247

  Set-up No.:                                                                                                          1

  Op. Mode:                                                                                                            1

                                                    Fundamental Value
                                                                                      Peak-Value                                                                                Remark:
                                                        [dBuV/m]
            Channel           Restricted                                                at Band-         Difference          Limit         Margin
Diagram No.                                                       Average -Value +                                                                Verdict
              No.              band ?                                                     Edge              [dB]            [dBc]           [dB]
                                              Peak-Value             Duty Cycle                                                                                     Data Rate | Power | Hopping ?
                                                                     Correction        [dBuV/m]


    9.57             0            NO                96,24               86,13             51,41              44,83           20,00           24,83   PASS   LE Mode | GFSK | 1 Mbps |+7 dBm | Hopping OFF




  Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1
  Remark 2: Measurements results are only valid and compliant with power setting: +7 dBm




5.6.6.2. Restricted bands near-by §15.205 with limits accord. FCC §15.209


  Set-up No.:                                                                                                         1

  Op. Mode:                                                                                                           1

                                          Fundamental Value             Value at Band-Edge               Limits                   Margin
                                                                                                                                                                              Remark:
                                              [dBuV/m]                       [dBuV/m]                  [dBuV/m]                    [dB]
              Channel    Restricted
Diagram No.                                                                           Average -                                                 Verdict
                no.       band ?                     Average -Value +
                                                                          Peak       Value + Duty    Peak    Average
                                       Peak-Value       Duty Cycle                                                         Peak      Average                        Data Rate | Power | Hopping ?
                                                                         -Value         Cycle       -Value    -Value
                                                        Correction
                                                                                      Correction


   9.58         39          YES         98,058           97,392          58,11         48,79        74,00     54,00       15,89       5,21      PASS         LE Mode | GFSK | 1 Mbps |+7 dBm | Hopping OFF




  Remark 1: For further details please refer  Annex 1: Test results - CETECOM_TR17-1-0180901T11a-A1
  Remark 2: Measurements results are only valid and compliant with power setting: +7 dBm




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 26 of 31

5.7. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k. such that a confidence level of approximately 95% is achieved.
For uncertainty determination. each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
     RF-Measurement           Reference         Frequency range                                                  Remarks
                                                                           confidence level of 95%
 Conducted emissions                      9 kHz - 150 kHz          4.0 dB
                             CISPR 16-2-1                                                                            -
 (U CISPR)                                150 kHz - 30 MHz         3.6 dB
 Radiated emissions                       30 MHz - 1 GHz           4.2 dB
                             CISPR 16-2-3                                                                         E-Field
 Enclosure                                1 GHz - 18 GHz           5.1 dB
 Disturbance power           CISPR 16-2-2 30 MHz - 300 MHz         -                                                 -
                                                                                                                Substitution
 Power Output radiated            -           30 MHz - 4 GHz       3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                              Set-up No.                        BT1 W1          W2         --
                                                                    C1     C2
 Power Output conducted           -           9 kHz - 12.75 GHz    N/A 0.60 0.7 0.25           N/A         --        -
                                              12.75 - 26.5GHz      N/A 0.82      --   N/A      N/A         --
 Conducted emissions              -           9 kHz - 2.8 GHz      0.70 N/A 0.70 N/A           0.69        --    N/A - not
 on RF-port                                   2.8 GHz - 12.75GHz   1.48 N/A 1.51 N/A           1.43        --    applicable
                                              12.75 GHz - 18GHz    1.81 N/A 1.83 N/A           1.77        --
                                              18 GHz - 26.5GHz     1.83 N/A 1.85 N/A           1.79        --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
 Occupied bandwidth               -           9 kHz - 4 GHz                                                     error
                                                                   1.0 dB                                       Power
                                  -                                0.1272 ppm (Delta Marker)                    Frequency
 Emission bandwidth                           9 kHz - 4 GHz                                                     error
                                  -                                See above: 0.70 dB                           Power
 Frequency stability              -           9 kHz - 20 GHz       0.0636 ppm                                         -
                                              150 kHz - 30 MHz     5.0 dB                                       Magnetic
 Radiated emissions                           30 MHz - 1 GHz       4.2 dB                                       field
                                  -
 Enclosure                                    1 GHz - 20 GHz       3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties. valid for conducted/radiated measurements




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 27 of 31


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV . AVG. CAV           Average detector
 EIRP                    Equivalent isotropically radiated power. determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission. USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification. Documents from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS. Deutsche
                         All laboratories and test sites of CETECOM GmbH. Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz. 3 m / 10 m (OATS)
                                                                                              FCC. Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz. 3 m (SAR)
      (MRA US-EU                                                                              Commission
 558                 Radiated Measurements above 1 GHz. 3 m (FAR)
          0003)                                                                               Laboratory Division. USA
 348                 Mains Ports Conducted Interference Measurements
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz. 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz. 3 m (SAR)                         IC. Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz. 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz. 3 m (FAR)
 487     R-2666      Radiated Measurements 30 MHz to 1 GHz. 3 m (SAR)
                                                                                              VCCI. Voluntary Control Council
 550     G-301       Radiated Measurements 1 GHz to 6 GHz. 3 m (SAR)
                                                                                              for Interference by Information
 348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment. Japan
 348     T-1967      Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site. SAR = Semi Anechoic Room. FAR = Fully Anechoic Room




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 28 of 31


8. Instruments and Ancillary
TC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053          Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140          Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355          Power Meter                               URV 5                    891310/027          Firm.= 1.31
365          10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
598          Spectrum Analyzer                         FSEM 30                  831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
607          Signal Generator                          SMR 20                   832033/011          V1.25
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670          Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689          Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 29 of 31

8.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                              calibration
                                                                                                                              Interval of



                                                                                                                                                Remark
                           Equipment                             Type               Serial-No.             Manufacturer                                      Cal
                                                                                                                                                             due

001         EMI Test Receiver                         ESS                     825132/017              Rohde & Schwarz         12 M          -            16.05.2018
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005              Rohde & Schwarz         12 M          -            15.05.2018
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002              Rohde & Schwarz         12 M          -            17.05.2018
009         Power Meter (EMS-radiated)                NRV                     863056/017              Rohde & Schwarz         24 M          -            15.05.2019
016         Line Impedance Simulating Network         Op. 24-D                B6366                   Spitzenberger+Spies     36 M          -            30.05.2019
021         Loop Antenna (H-Field)                    6502                    9206-2770               EMCO                    36 M          -            30.04.2018
030         Loop Antenna (H-field)                    HFH-Z2                  879604/026              Rohde & Schwarz         36 M          -            30.04.2018
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18               Rohde & Schwarz         24 M          -            15.05.2019
057         relay-switch-unit (EMS system)            RSU                     494440/002              Rohde & Schwarz         pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                B6363                   Spitzenberger+Spies     -             3
086         DC - power supply, 0 -10 A                LNG 50-10               -                       Heinzinger Electronic   pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S               -                       Elektro Automatik       pre-m         2
091         USB-LWL-Converter                         OLS-1                   007/2006                Ing. Büro Scheiba       -             4
099         passive voltage probe                     ESH2-Z3                 299.7810.52             Rohde & Schwarz         36 M          -            30.04.2018
100         passive voltage probe                     Probe TK 9416           without                 Schwarzbeck             36 M          -            30.04.2018
110         USB-LWL-Converter                         OLS-1                   -                       Ing. Büro Scheiba       -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547                  BOCONSULT               36 M          -            30.05.2019
133         horn antenna 18 GHz (Meas 1)              3115                    9012-3629               EMCO                    36 M          1c           10.03.2020
134         horn antenna 18 GHz (Subst 2)             3115                    9005-3414               EMCO                    36 M          -            10.03.2020
136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697               EMCO                    36 M          -            30.04.2018
140         Signal Generator                          SMHU                    831314/006              Rohde & Schwarz         24 M          -            30.05.2018
248         attenuator                                SMA 6dB 2W              -                       Radiall                 pre-m         2
249         attenuator                                SMA 10dB 10W            -                       Radiall                 pre-m         2
252         attenuator                                N 6dB 12W               -                       Radiall                 pre-m         2
256         attenuator                                SMA 3dB 2W              -                       Radiall                 pre-m         2
257         hybrid                                    4031C                   04491                   Narda                   pre-m         2
260         hybrid coupler                            4032C                   11342                   Narda                   pre-m         2
261         Thermal Power Sensor                      NRV-Z55                 825083/0008             Rohde & Schwarz         24 M          -            30.05.2018
262         Power Meter                               NRV-S                   825770/0010             Rohde & Schwarz         24 M          -            30.05.2018
263         Signal Generator                          SMP 04                  826190/0007             Rohde & Schwarz         36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04       840414/009              Rohde & Schwarz         24 M          -            30.05.2018
266         Peak Power Sensor                         NRV-Z31, Model 04       843383/016              Rohde & Schwarz         24 M          -            30.05.2018
267         notch filter GSM 850                      WRCA 800/960-6EEK       9                       Wainwright GmbH         pre-m         2
270         termination                               1418 N                  BB6935                  Weinschel               pre-m         2
271         termination                               1418 N                  BE6384                  Weinschel               pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                BF6239                  Weinschel               pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                BF9229                  Weinschel               pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321                  Weinschel               pre-m         2
275         DC-Block                                  Model 7003 (N)          C5129                   Weinschel               pre-m         2
276         DC-Block                                  Model 7006 (SMA)        C7061                   Weinschel               pre-m         2
279         power divider                             1515 (SMA)              LH855                   Weinschel               pre-m         2
298         Univ. Radio Communication Tester          CMU 200                 832221/091              Rohde & Schwarz         pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020             Rohde & Schwarz         12 M          -            17.05.2018
301         attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272                  Lucas Weinschel         pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                155                     Schwarzbeck             36 M          -            14.03.2020
303         horn antenna 40 GHz (Subst 1)             BBHA9170                156                     Schwarzbeck             36 M          -            20.03.2020
331         Climatic Test Chamber -40/+180 Grad       HC 4055                 43146                   Heraeus Vötsch          24 M          -            30.10.2018
341         Digital Multimeter                        Fluke 112               81650455                Fluke                   24 M          -            30.05.2018
342         Digital Multimeter                        Voltcraft M-4660A       IB 255466               Voltcraft               24 M          -            17.05.2019
347         laboratory site                           radio lab.              -                       -                       -             5
348         laboratory site                           EMI conducted           -                       -                       -             5
354         DC - Power Supply 40A                     NGPE 40/40              448                     Rohde & Schwarz         pre-m         2
355         Power Meter                               URV 5                   891310/027              Rohde & Schwarz         24 M          -            30.05.2018
357         power sensor                              NRV-Z1                  861761/002              Rohde & Schwarz         24 M          -            24.05.2019
371         Bluetooth Tester                          CBT32                   100153                  R&S                     36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535                  Rohde & Schwarz         12 M          -            17.05.2018
377         EMI Test Receiver                         ESCS 30                 100160                  Rohde & Schwarz         12 M          -            15.05.2018
392         Radio Communication Tester                MT8820A                 6K00000788              Anritsu                 12 M          -            18.05.2018
                                                                              126.0604.0003.3.3.3.2   LUFFT Mess u.
405         Thermo-/Hygrometer                        OPUS 10 THI                                                             24 M          -            30.03.2019
                                                                              2                       Regeltechnik
431         Model 7405                                Near-Field Probe Set    9305-2457               EMCO                    -             4
436         Univ. Radio Communication Tester          CMU 200                 103083                  Rohde & Schwarz         12 M          -            24.05.2018
439         UltraLog-Antenna                          HL 562                  100248                  Rohde & Schwarz         36 M          -            10.03.2020
454         Oscilloscope                              HM 205-3                9210 P 29661            Hameg                   -             4
456         DC-Power supply 0-5 A                     EA 3013 S               207810                  Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50           910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                 108901                  Rohde & Schwarz         12 M          -            16.06.2018
463         Universal source                          HP3245A                 2831A03472              Agilent                 -             4
466         Digital Multimeter                        Fluke 112               89210157                Fluke USA               24 M          -            30.05.2018


CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 30 of 31
 Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                             Equipment                           Type                     Serial-No.            Manufacturer                                      Cal
                                                                                                                                                                  due

467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA                36 M          -            30.04.2018
468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA                36 M          -            30.04.2018
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink    -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz          24 M          -            16.05.2019
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)            -             1d
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                                24 M          -            31.03.2019
                                                      NSA                                                 CETECOM
489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz          12 M          -            18.05.2019
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright               pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright               pre-m         2
                                                      WRCA 800/960-02/40-
512         notch filter GSM 850                                                  SN 24                   Wainwrght                12 M          1c           30.06.2017
                                                      6EEK
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                 pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                  24 M          -            18.05.2019
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel                pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                        pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                      12 M          -            30.03.2018
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz          12 M          -            05.07.2018
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz          36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                               -                                                24 M          -            30.03.2019
            EMI                                       VSWR                                                Lindgren/CETECOM
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                      24 M          -            08.08.2019
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia                36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz          pre-m         -
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz          pre-m         -
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz          24 M          -            17.05.2019
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz          24 M          -            15.05.2019
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz          24 M          -
611         DC power supply                           E3632A                      KR 75305854             Agilent                  pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                  pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                  pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                    24 M          -            30.05.2018
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits            -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA       -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA      -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz            12 M          -            16.05.2018
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz          pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                  -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH            24 M          -            30.03.2019
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz          pre-m         2
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                 -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                 -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                 -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                 -             2
642         Wideband Radio Communication Tester       CMW 500                     126089                  Rohde&Schwarz            12 M          -            24.05.2018
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits            -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz          24 M          -            30.05.2018
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik        pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz            pre-m         -
683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz          12 M          -            17.05.2018
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                       24 M          -            29.03.2019
                                                                                                          Solutions
687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz            12 M          -            17.05.2018
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                    pre-m         -
690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz            12 M          -            16.05.2018
691         OSP120 Base Unit                          OSP120                      101183                  Rohde & Schwarz          12 M          -            22.05.2018
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz          36 M          -            29.05.2020
697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits            -             2
                                                      MA 4010-KT080-XPET-         MA4170-KT100-
703         INNCO Antennen Mast                                                                           INNCO                    pre-m         -
                                                      ZSS3                        XPET-
                                                                                  CO3000/933/3841051
704         INNCON Controller                         CO 3000-4port                                       INNCO Systems GmBh       pre-m         -
                                                                                  6/L
711         Harmonic Mixer 90 GHz - 140GHz            RPG FS-Z140                 101004                  RPG                      12 M          -            22.02.2018
712         Harmonic Mixer 75 GHz - 110GHz            FS-Z110                     101468                  Rohde & Schwarz          12 M          -            22.02.2018
713         Harmonic Mixer, 50 GHz - 75GHz            FS-Z75                      101022                  Rohde & Schwarz          12 M          -            22.05.2018
714         Signal Analyzer 67GHz                     FSW67                       104023                  Rohde & Schwarz          24 M          -            03.03.2019
                                                                                                          RPG Radiometer
715         Harmonic Mixer, 140 GHz - 220GHz          FS-Z220                     101009                                           12 M          -            03.08.2018
                                                                                                          Physics
716         Harmonic Mixer 220 GHz to 325 GHZ         FS-Z325                     101005                  RPG Radiometer Physics   12 M          -            13.02.2018
747         Spectrum Analyzer                         FSU 26                      200152                  Rohde & Schwarz          12 M          -            18.05.2018


CETECOM_TR17-1-0180901T11a


Test Report 17-1-0180901T11a, Page 31 of 31
 Ref.-No.




                                                                                                                                        calibration
                                                                                                                                        Interval of



                                                                                                                                                          Remark
                           Equipment                             Type                    Serial-No.              Manufacturer                                      Cal
                                                                                                                                                                   due

748         Pickett-Potter Horn Antenna               FH-PP 4060                   010001                   Radiometer Physiscs         -             -
749         Pickett-potter Horn Antenna               FH-PP 60-90                  010003                   Radiometer Physics          -             -
750         Pickett-Potter Horn Antenna               FH-PP 140-220                010011                   Radiometer Physics          -             -




8.1.3. Legend
 Note / remarks                            Calibrated during system calibration:
                                 1a        System CTC-SAR-EMS (Ref.-No. 442)
                                 1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                                 1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                 1d        System CTC-SAR-EMI (Ref.-No . 441)
                                 1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                 1f        System CTC-CTIA-OTA (Ref.-No . 420)
                                 1g        System CTC-FAR-EMS (Ref.-No . 444)
                                 2         Calibration or equipment check immediately before measurement
                                 3         Regulatory maintained equipment for functional check or support purpose
                                 4         calibration of this equipment
                                           Ancillary equipment   without has no effect
                                                                         calibration   onmechanical
                                                                                     e.g. measuring result
                                                                                                    equipment or monitoring equipment
                                 5         Test System


Interval of calibration          12 M      12 month
                                 24 M      24 month
                                 36 M      36 month
                                 24/12 M   Calibration every 24 months. between this every 12 months internal validation
                                 36/12 M   Calibration every 36 months. between this every 12 months internal validation
                                 Pre-m     Check before starting the measurement
                                 -         Without calibration




9. Versions of test reports (change history)

            Version            Applied changes                                                                                      Date of release
              --               Inital release                                                                                        2017-12-27
              --               --                                                                                                         --
              --               --                                                                                                         --




CETECOM_TR17-1-0180901T11a



Document Created: 2018-01-30 00:39:56
Document Modified: 2018-01-30 00:39:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC