Test report

FCC ID: U4GFX3P

Test Report

Download: PDF
FCCID_2382521

FCC Measurement/Technical Report on
WLAN / Bluetooth transceiver
in

Mobile Handheld Computer
Datalogic Falcon X3+

FCC ID: U4GFX3P



Report Reference: MDE_DATA_1405_FCCi_Rev1




Test Laboratory:
Borsigstrasse 11
Germany
7Layers AG
40880 Ratingen

Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7 layers AG                                        Aufsichtsratsvorsitzender                    Registergericht registered in:
Borsigstrasse 11                                   Chairman of the Supervisory Board:            Düsseldorf, HRB 44096
40880 Ratingen, Germany                            Peter Mertel                                  USt-IdNr  VAT No.:
Phone: +49 (0) 2102 749 0                          Vorstand Board:                              DE 203159652
Fax: +49 (0) 2102 749 350                          Dr. H.-J. Meckelburg                          TAX No. 147/5869/0385
www.7Layers.com                                    Dr. H. Ansorge


Table of Contents

0     Applied Standards and Test Summary            3
0.1    Technical Report Summary                     3
0.2    FCC and IC Correlation Table                 4
0.3    Measurement Summary                          5

1     Administrative Data                           7
1.1    Testing Laboratory                           7
1.2    Project Data                                 7
1.3    Applicant Data                               7
1.4    Manufacturer Data                            7

2     Test object Data                              8
2.1    General EUT Description                      8
2.2    EUT Main components                          9
2.3    Ancillary Equipment                          9
2.4    Auxiliary Equipment                          9
2.5    EUT Setups                                   9
2.6    Operating Modes                             10
2.7    Special software used for testing           11
2.8    Product labelling                           11

3     Test Results                                12
3.1    Spurious radiated emissions                 12
3.2    Band edge compliance                        18

4     Test Equipment                              21

5     Photo Report                                32

6     Setup Drawings                              32




Test report Reference: MDE_DATA_1405_FCCi_Rev1   Page 2 of 32


0     Applied Standards and Test Summary

0.1   Technical Report Summary

Type of Authorization
Certification for an Intentional Radiator (Digital Device / Spread Spectrum).

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in
47 CFR Ch.1 Parts 2 and 15 (10-1-13 Edition). The following subparts are applicable to
the results in this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification


Part 15, Subpart C – Intentional Radiators

§ 15.201   Equipment authorization requirement

§ 15.207   Conducted limits

§ 15.209   Radiated emission limits; general requirements

§ 15.247   Operation within the bands 902-928 MHz, 2400-2483.5 MHz




Note:
The tests were selected and performed with reference to the FCC Public Notice “Guidance
for Performing Compliance Measurements on Digital Transmission Systems
(DTS)Operating Under §15.247, 558074 D01 DTS Meas Guidance v03r02, 2014-06-05”.

Instead of applying ANSI C63.4–1992 which is referenced in the FCC Public Note, the
newer ANSI C63.4–2009 is applied.



Summary Test Results:

The EUT complied with all performed tests as listed in chapter 0.3 Measurement
Summary.




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                  Page 3 of 32


0.2   FCC and IC Correlation Table

Correlation of measurement requirements for
DTS devices (e.g. WLAN 2.4/5 GHz) equipment

The following tables show the correlation of measurement requirements for DTS (e.g.
WLAN) equipment and Information Technology Equipment (ITE) from FCC and IC
standards.


DTS equipment

Measurement                     FCC reference                 IC reference
Conducted emissions on          § 15.207                      RSS-Gen Issue 3: 7.2.4
AC Mains
Occupied bandwidth              § 15.247 (a) (2)              RSS-210 Issue 8: A8.2 (a)
Peak power output               § 15.247 (b) (3), (4)         RSS-210 Issue 8: A8.4 (4)
Spurious RF conducted           § 15.247 (d)                  RSS-Gen Issue 3: 6;
emissions                                                     RSS-210 Issue 8: A8.5
Spurious radiated emissions     § 15.247 (d);                 RSS-Gen Issue 3: 6;
                                § 15.209 (a)                  RSS-210 Issue 8: A8.5
Band edge compliance            § 15.247 (d)                  RSS-210 Issue 8: A8.5
Power density                   § 15.247 (e)                  RSS-210 Issue 8: A8.2 (b)
Antenna requirement             § 15.203 / 15.204             RSS-Gen Issue 3: 7.1.2
Receiver spurious emissions     –                             RSS-210 Issue 8: 2.3
                                                              RSS Gen Issue 3: 6 *)

*) Receivers which are part of Transceivers are exempted with respect to Notice 2012-DRS0126.



Information Technology Equipment (ITE)

Measurement                     FCC reference                 IC reference
Conducted emissions on          § 15.107                      ICES-003 Issue 5: 6.1
AC Mains
Spurious Radiated Emissions     § 15.109                      ICES-003 Issue 5: 6.2




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                       Page 4 of 32


0.3   Measurement Summary

FCC Part 15, Subpart C                § 15.207
Conducted emissions (AC power line)
The measurement was performed according to ANSI C63.4      2009
OP-Mode            Setup              Port                 Final Result
-                  -                  AC port              N/A

FCC Part 15, Subpart C                § 15.247 (a) (1)
Occupied bandwidth
The measurement was performed according to FCC § 15.31     10-1-13 Edition
OP-Mode            Setup              Port                 Final Result
op-mode 1b         Setup_01           Temp.ant.connector   Not performed

FCC Part 15, Subpart C                § 15.247 (b) (1)
Peak power output
The measurement was performed according to FCC § 15.31     10-1-13 Edition
OP-Mode           Setup               Port                 Final Result
-                 -                   Temp.ant.connector   Not performed

FCC Part 15, Subpart C                § 15.247 (d), § 15.35 (b), § 15.207
Spurious conducted emissions
The measurement was performed according to ANSI C63.4      2009
OP-Mode             Setup             Port                 Final Result
-                   -                 Temp.ant.connector   Not performed

FCC Part 15, Subpart C                § 15.247 (d), § 15.35 (b), § 15.209
Spurious radiated emissions
The measurement was performed according to ANSI C63.4      2009
OP-Mode             Setup             Port                 Final Result
op-mode 1b          Setup_01          Enclosure            passed
op-mode 2b          Setup_01          Enclosure            passed
op-mode 3b          Setup_01          Enclosure            passed
op-mode 1g          Setup_01          Enclosure            passed
op-mode 2g          Setup_01          Enclosure            passed
op-mode 3g          Setup_01          Enclosure            passed
op-mode 1n          Setup_01          Enclosure            passed
op-mode 2n          Setup_01          Enclosure            passed
op-mode 3n          Setup_01          Enclosure            passed
op-mode BT1-BDR Setup_01              Enclosure            passed
op-mode BT2-BDR Setup_01              Enclosure            passed
op-mode BT3-BDR Setup_01              Enclosure            passed
op-mode BT1-ED1 Setup_01              Enclosure            passed
op-mode BT2-ED1 Setup_01              Enclosure            passed
op-mode BT3-ED1 Setup_01              Enclosure            passed
op-mode BT1-ED2 Setup_01              Enclosure            passed
op-mode BT2-ED2 Setup_01              Enclosure            passed
op-mode BT3-ED2 Setup_01              Enclosure            passed




Test report Reference: MDE_DATA_1405_FCCi_Rev1                            Page 5 of 32


FCC Part 15, Subpart C                § 15.247 (d)
Band edge compliance
The measurement was performed according to FCC § 15.31 /              10-1-13 Edition /
ANSI C63.4                                                            2009
OP-Mode            Setup              Port                            Final Result
op-mode 3b         Setup_01           Enclosure                       passed
op-mode 3g         Setup_01           Enclosure                       passed
op-mode 3n         Setup_01           Enclosure                       passed
op-mode BT3-BDR Setup_01              Enclosure                       passed
op-mode BT3-ED1 Setup_01              Enclosure                       passed
op-mode BT3-ED2 Setup_01              Enclosure                       passed



FCC Part 15, Subpart C                § 15.247 (e)
Power density
The measurement was performed according to FCC § 15.31                10-1-13 Edition
OP-Mode           Setup               Port                            Final Result
-                 -                   Temp.ant.connector              Not performed

N/A     not applicable (the EUT is powered by DC)




Responsible for                                  Responsible
Accreditation Scope:                             for Test Report:




0.4    Revision History

                                Report version control
 Version         Release date    Change Description                   Version validity
 FCCi            2014-08-13      Initial version                      Not valid
 FCCi_Rev1       2014-08-26      Editorial Change after TCB review:   valid
                                 Bluetooth transceiver added on
                                 frontpage and in chapter 2.2 EUT
                                 description




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                     Page 6 of 32


1     Administrative Data

1.1   Testing Laboratory

Company Name:                               7 Layers AG

Address                                     Borsigstr. 11
                                            40880 Ratingen
                                            Germany

This facility has been fully described in a report submitted to the FCC and accepted
under the registration number 96716 .

The test facility is also accredited by the following accreditation organisation:
Laboratory accreditation no.:                DAkkS D-PL-12140-01-01

Responsible for Accreditation Scope:        Dipl.-Ing.   Bernhard Retka
                                            Dipl.-Ing.   Robert Machulec
                                            Dipl.-Ing.   Thomas Hoell
                                            Dipl.-Ing.   Andreas Petz
                                            Dipl.-Ing.   Marco Kullik

Report Template Version:                    2014-08-26


1.2   Project Data

Responsible for testing and report:         Dipl.-Ing. Marco Kullik

Date of Test(s):                            2014-06-03 to 2014-07-21
Date of Report:                             2014-08-13


1.3   Applicant Data

Company Name:                               Datalogic ADC s.r.l.

Address:                                    Via S. Vitalino, 13
                                            40012 Lippo di Calderara di Reno, Bologna
                                            Italy
Contact Person:
                                            Mr. Eucarpio Guarisco


1.4   Manufacturer Data
Company Name:                               Please see applicant data

Address:


Contact Person:




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                      Page 7 of 32


2     Test object Data

2.1   General EUT Description

Equipment under Test:                 IEEE 802.11a/b/g/n WLAN & BT transceiver
Type Designation:                     Datalogic FALCON X3+
Kind of Device:                       Mobile Handheld Computer
(optional)
Voltage Type:                         DC
Voltage Level:                        5.0 V
Tested Modulation Type:               WLAN: DBPSK; OFDM:BPSK; OFDM: 64-QAM
                                      BT: GFSK, π/4-DQPSK, 8-DPSK


General product description:

The EUT is a mobile handheld computer. It runs with Windows Mobile 6 CE.


Specific product description for the EUT:

The EUT is a dual band WLAN (802.11 a/b/g/n, 2.4 and 5 GHz) and Bluetooth module
with one joint antenna connector for WLAN and Bluetooth. In IEEE 802.11n mode it only
supports 20 MHz bandwidth channels (MCS7), providing 72.2 Mbit/s transfer data rates
respectively.

The object of this test report is the BT and WLAN transceiver, consequently switched on
the IEEE 802.11 b/g/n modes, working in the 2.4 band. In IEEE 802.11n mode, it was
tested with 20 MHz channel bandwidth.


The EUT provides the following ports:

Ports
Enclosure
System-port


The main components of the EUT are listed and described in Chapter 2.2




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                   Page 8 of 32


2.2    EUT Main components

Type, S/N, Short Descriptions etc. used in this Test Report

      Short          Equipment           Type           Serial No.      HW Status         SW Status
  Description        under Test      Designation
EUT A              WLAN & BT        FALCON X3+        5M               P/N:                1.88 and
(Code:             transceiver                                         945250051          subsequent
DE1006002aa01)
Remark: EUT A is equipped with two dual-band integral antennas (2.4 & 5 GHz) frequency band with a
        maximal antenna gain of 4.2 dBi in the 4.9 – 5.9 GHz frequency range.
EUT A              WLAN & BT        FALCON X3+        9I               P/N:                1.88 and
(Code:             transceiver                                         945250055          subsequent
DE1006002ab01)
Remark: EUT A is equipped with two dual-band integral antennas (2.4 & 5 GHz) frequency band with a
        maximal antenna gain of 4.2 dBi in the 4.9 – 5.9 GHz frequency range.

NOTE: The short description used to simplify the identification of the EUT in this test report.



2.3    Ancillary Equipment

For the purposes of this test report, ancillary equipment is defined as equipment, which
is used in conjunction with the EUT to provide operational and control features to the
EUT. It is necessary to configure the system in a typical fashion, as a customer would
normally use it. But nevertheless Ancillary Equipment can influence the test results.

  Short           Equipment under        Type Designation         Serial No.          HW           SW
Description            Test                                                          Status       Status
-             –                      –                        –                  –            –




2.4    Auxiliary Equipment

For the purposes of this test report, auxiliary equipment is defined as equipment, which
is used temporarily to enable operational and control features especially used for the
tests of the EUT, which is not used during normal operation or equipment that is used
during the tests in combination with the EUT but is not subject of this test report. It is
necessary to configure the system in a typical fashion, as a customer would normally use
it. But nevertheless Auxiliary Equipment can influence the test results.

  Short           Equipment under        Type Designation         Serial No.          HW           SW
Description            Test                                                          Status       Status
-             –                      –                        –                  –            –




2.5    EUT Setups

This chapter describes the combination of EUTs and equipment used for testing. The
rationale for selecting the EUTs, ancillary and auxiliary equipment and interconnecting
cables, is to test a representative configuration meeting the requirements of the
referenced standards.

 Setup        Combination of EUTs                            Description and Rationale
Setup_01            EUT A                setup for radiated radio measurements



Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                Page 9 of 32


2.6     Operating Modes

This chapter describes the operating modes of the EUTs used for testing.


2.6.1     Test Channels

 Band:
                            WLAN 2.4 GHz ISM
 900 MHz
 902 - 928 MHz              2400 - 2483.5 MHz
 Bottom    Middle     Top   Bottom    Middle     Top
                               1        6         11
                             2412      2437      2462



 Band:
                            BT 2.4 GHz ISM
 900 MHz
 902 - 928 MHz              2400 - 2483.5 MHz
 Bottom    Middle     Top   Bottom    Middle     Top
                               0        39        78
                             2402      2441      2480




2.6.2     Datarates

 SISO:

 WLAN b-Mode; 20 MHz; 6 Mbit/s
 WLAN g-Mode; 20 MHz; 11 Mbit/s
 WLAN n-Mode; 20 MHz; 72.2 Mbit/s
 BT 1-DH1; 1 Mbit/s
 BT 2-DH1; 2 Mbit/s
 BT 3-DH1; 3 Mbit/s

WLAN:
Data rate / frequency                2412         2437      2462
b-mode, 6 Mbit/s                      1b           2b        3b
g-mode, 11 Mbit/s                     1g           2g        3g
n-Mode, 72.2 Mbit/s (MCS7)            1n           2n        3n

BT:
Data rate / frequency                2402          2441      2480
BT 1-DH1; 1 Mbit/s                 BT1-BDR       BT2-BDR   BT3-BDR
BT 2-DH1; 2 Mbit/s                 BT1-ED1       BT2-ED1   BT3-ED1
BT 3-DH1; 3 Mbit/s                 BT1-ED2       BT2-ED2   BT3-ED2




Test report Reference: MDE_DATA_1405_FCCi_Rev1                             Page 10 of 32


2.7     Special software used for testing

The Windows program “SRU” is used to control the WLAN module.



2.8     Product labelling

2.8.1    FCC ID label
Please refer to the documentation of the applicant.

2.8.2    Location of the label on the EUT
Please refer to the documentation of the applicant.




Test report Reference: MDE_DATA_1405_FCCi_Rev1                  Page 11 of 32


3       Test Results

3.1     Spurious radiated emissions

Standard       FCC Part 15, Subpart C

The test was performed according to: ANSI C63.4

3.1.1    Test Description
The test set-up was made in accordance to the general provisions of ANSI C63.4 in a
typical installation configuration. The Equipment Under Test (EUT) was set up on a non-
conductive table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT
support table that is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software ES-K1 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case
orientation of a body-worn or handheld EUT. The final test on all kind of EUTs is
performed at 2 axes. A pre-check is performed while the EUT is powered from a DC
power sourse.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.
Step 1: pre measurement
- Anechoic chamber
- Antenna distance: 10 m
- Detector: Peak-Maxhold
- Frequency range: 0.009 - 0.15 MHz and 0.15 – 30 MHz
- Frequency steps: 0.1 kHz and 5 kHz
- IF–Bandwidth: 0.2 kHz and 10 kHz
- Measuring time / Frequency step: 100 ms
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is to find the maximum
emission level.
- Open area test side
- Antenna distance: according to the Standard
- Detector: Quasi-Peak
- Frequency range: 0.009 – 30 MHz
- Frequency steps: measurement at frequencies detected in step 1
- IF–Bandwidth: 0.2 - 10 kHz
- Measuring time / Frequency step: 100 ms




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                  Page 12 of 32


2. Measurement above 30 MHz and up to 1 GHz
Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold
- Frequency range: 30 – 1000 MHz
- Frequency steps: 60 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 µs
- Turntable angle range: –180° to 180°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: second measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is, to find out the approximate
turntable angle and antenna height for each frequency.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –180° to 180°
- Turntable step size: 45°
- Height variation range: 1 – 4 m
- Height variation step size: 0.5 m
- Polarisation: horizontal + vertical
After this step, the EMI test system has determined the following values for each
frequency (of step 1):
- Frequency
- Azimuth value (of turntable)
- Antenna height
The last two values have now the following accuracy:
- Azimuth value (of turntable): 45°
- Antenna height: 0.5 m
Step 3: final measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved.
This is necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will
be adjusted. The turntable azimuth will slowly vary by ± 22.5° around this value. During
this action, the value of emission is continuously measured. The turntable azimuth at the
highest emission will be recorded and adjusted. In this position, the antenna height will
also slowly vary by ± 25 cm around the antenna height determined. During this action,
the value of emission is also continuously measured. The antenna height of the highest
emission will also be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 22.5 ° around the determined value
- Height variation range: ± 25 cm around the determined value




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                   Page 13 of 32


Step 4: final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak (< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results
of the preliminary scan and a chart with the frequencies and values of the results of the
final measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
The Equipment Under Test (EUT) was set up on a non-conductive support at 1.4 m
height in the fully-anechoic chamber. The measurement distance was reduced to 1 m.
The results were extrapolated by the extrapolation factor of 20 dB/decade (inverse
linear-distance for field strength measurements, inverse linear-distance squared for the
power reference level measurements). Due to the fact, that in this frequency range a
double-ridged wave guided horn antenna (up to 18 GHz) and a horn antenna (18–25
GHz) are used, the steps 2-4 are omitted. Step 1 was performed with one height of the
receiving antenna only.
EMI receiver settings:
- Detector: Peak, Average
- IF Bandwidth = 1 MHz

For the data rate in mode n the test is performed as worst-case-check in order to verify
that emissions have a comparable level as found at modes b and g. Typically, the
measurement is performed in the frequency range 1 to 8 GHz but it depends on the
emissions found during the test for the modes b and g. Please refer to the results for the
used frequency range.


3.1.2   Test Requirements / Limits
FCC Part 15, Subpart C, §15.247 (e)

For digitally modulated systems, the peak power spectral density conducted from the
intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band
during any time interval of continuous transmission.
…
The same method of determining the conducted output power shall be used to determine
the power spectral density.




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                 Page 14 of 32


3.1.3       Test Requirements / Limits
FCC Part 15, Subpart C, §15.247 (d)
... In addition, radiated emissions which fall in the restricted bands, as defined in Section
15.205(a), must also comply with the radiated emission limits specified in Section
15.209(a) (see Section 15.205(c)).

FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

                                    Measurement      Calculated Limits(dBµV/m
Frequency in MHz   Limit (µV/m)                                                  Limits(dBµV/m @10m)
                                    distance (m)              @10m)
0.009 – 0.49       2400/F(kHz)    300      59.1 dB   (48.5 – 13.8) + 30 dB      78.5 – 43.8
0.49 – 1.705       24000/F(kHz)   30       19.1 dB   (48.9 – 23.0) + 10 dB      58.9 – 33.0
1.705 – 30         30             30       19.1 dB   29.5 + 10 dB               39.5

                                      Measurement
Frequency in MHz   Limit (µV/m)                             Limit (dBµV/m)
                                      distance (m)
30 – 88            100            3                  40.0
88 – 216           150            3                  43.5
216 – 960          200            3                  46.0
above 960          500            3                  54.0


§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the
maximum permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                            Page 15 of 32


3.1.4     Test Protocol

Temperature:        23–27 °C
Air Pressure:       997-1011 hPa
Humidity:           33–50 %


 WLAN b-Mode; 20 MHz; 6 Mbit/s
           Channel                                                                                     Margin
            Center                           Spurious                                                     to
  Ch.     Frequency        Frequency           Level                       RBW          Limit           Limit         Limit
  No.       [MHz]            [MHz]            [dBm]         Detector       [kHz]      [dBµV/m]          [dB]          Type
   1         2412            4824.0             47.2           AV           1000         54.0            6.8           RB
   6         2437            4874.0             42.6           AV           1000         54.0           11.4           RB
  11         2462            2384.0             40.4           AV           1000         54.0           13.6           RB
  11         2462            4924.0             39.1           AV           1000         54.0           14.9           RB

 BT 1-DH1; 1
 Mbit /s
          Channel                                                                                    Margin
           Center                            Spurious                                                   to
 Ch.     Frequency         Frequency           Level                       RBW           Limit        Limit          Limit
 No.       [MHz]             [MHz]            [dBm]         Detector       [kHz]        [dBm]         [dB]           Type
  -          -                 -                 -             -             -                                         -


Note:   No (further) spurious emissions in the range 20 dB below the limit found.
        The results of the pre-test with peak detector have been similar for all three transmit frequencies in the
        frequency range 30–1000 MHz and independent from the transmit frequency. Therefore the final test
        applying the QP-(quasi-peak-)detector was perfomed only for one transmit frequency.



 WLAN g-Mode; 20 MHz; 11 Mbit/s
       Channel                                                                                         Margin
        Center               Spurious                                                                     to
 Ch.  Frequency Frequency      Level                                       RBW          Limit           Limit         Limit
 No.    [MHz]      [MHz]      [dBm]                         Detector       [kHz]      [dBµV/m]          [dB]          Type
  1      2412      2389.0       43.0                           AV           1000         54.0           11.0           RB

 WLAN n-Mode; 20 MHz; 72.2 Mbit/s

           Channel                                                                                     Margin
            Center                           Spurious                                                     to
  Ch.     Frequency        Frequency           Level                       RBW          Limit           Limit         Limit
  No.       [MHz]            [MHz]            [dBm]         Detector       [kHz]      [dBµV/m]          [dB]          Type
   1         2412            2390.0             63.1         PEAK           1000         74.0           10.9           RB
   1         2412            2390.0             45.6           AV           1000         54.0            8.4           RB




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                      Page 16 of 32


 BT 2-DH1; 2 Mbit/s

          Channel                                                                           Margin
           Center                        Spurious                                              to
 Ch.     Frequency       Frequency         Level                    RBW         Limit        Limit        Limit
 No.       [MHz]           [MHz]          [dBm]        Detector     [kHz]      [dBm]         [dB]         Type
  -          -               -               -            -           -                                     -

 BT 3-DH1; 3 Mbit/s

          Channel                                                                           Margin
           Center                        Spurious                                              to
 Ch.     Frequency       Frequency         Level                    RBW         Limit        Limit        Limit
 No.       [MHz]           [MHz]          [dBm]        Detector     [kHz]      [dBm]         [dB]         Type
  -          -               -               -            -           -                                     -


Note:   No (further) spurious emissions in the range 20 dB below the limit found.
        The measurement was performed from 1 GHz up to 8 GHz because at pre-measurements no significant
        spurious emissions have been found outside this frequency range.




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                            Page 17 of 32


3.2     Band edge compliance

Standard       FCC Part 15, Subpart C

The test was performed according to: ANSI C63.4–2009, FCC §15.31

3.2.1    Test Description
The procedure to show compliance with the band edge requirement is divided into two
measurements:

1. Show compliance of the lower and higher band edge by a conducted measurement.
For the conducted measurement, the Equipment Under Test (EUT) is placed in a shielded
room.
For the lower band edge the EUT is set to transmit as follows:
For a WLAN transmitter working in the 2.4 GHz band on lowest channel:
CH1 = 2412 MHz / CH3 = 2422 MHz for a channel bandwidth of 20 / 40 MHz.
The lower band edge is 2400 MHz for 2.4 GHz band transmitter.
For the higher band edge the EUT is set to transmit as follows:
For a WLAN transmitter working in the 2.4 GHz band on highest channel:
CH11 = 2462 MHz or CH13 = 2472 MHz / CH11= 2462 MHz for a channel bandwidth of
20 / 40 MHz.
The higher band edge is 2483.5 MHz for a 2.4 GHz band transmitter.
Analyzer settings for conducted measurement:
- Detector: Peak
- RBW / VBW = 100 / 300 kHz

2. Showing compliance of the higher band edge falls in to restricted bands by a radiated
measurement.
The radiated emissions measurements are performed in a typical installation
configuration inside the fully anechoic chamber using a horn antenna at 1 m distance.
EMI receiver settings for radiated measurement:
- Detector: Peak, Average
- IF Bandwidth = 1 MHz


3.2.2    Test Requirements / Limits
FCC Part 15.247 (d)
“In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or
digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz
bandwidth within the band that contains the highest level of the desired power, based on
either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. ...
If the transmitter complies with the conducted power limits based on the use of RMS
averaging over a time interval, as permitted under paragraph (b)(3) of this section, the
attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation
below the general limits specified in Section 15.209(a) is not required. In addition,
radiated emissions which fall in the restricted bands, as defined in Section 15.205(a),
must also comply with the radiated emission limits specified in Section 15.209(a) (see
Section 15.205(c)).”




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                Page 18 of 32


For the conducted measurement the RF power at the band edge shall be “at least 20 dB
below that in the 100 kHz bandwidth within the band that contains the highest level of
the desired power...”

For the radiated measurement of the higher band edge connected to a restricted band
the limit is “specified in Section 15.209(a)”.


3.2.3     Test Protocol

3.2.3.1    Radiated measurement, higher band edge

Temperature:     23–27 °C
Air Pressure:    997-1011 hPa
Humidity:        33–50 %

 WLAN b-Mode; 20 MHz; 6 Mbit/s

         Channel                                                                Margin
          Center                  Spurious                                         to
 Ch.    Frequency    Frequency      Level                   RBW       Limit      Limit    Limit
 No.      [MHz]        [MHz]       [dBm]         Detector   [kHz]   [dBµV/m]     [dB]     Type
 11        2462        2483.5        51.6         PEAK       1000      74.0      22.4      BE
 11        2462        2483.5        40.9           AV       1000      54.0      13.1      BE



 WLAN g-Mode; 20 MHz; 11 Mbit/s

         Channel                                                               Margin
          Center                  Spurious                                        to
 Ch.    Frequency    Frequency      Level                   RBW      Limit      Limit    Limit
 No.      [MHz]        [MHz]       [dBm]         Detector   [kHz]   [dBm]       [dB]     Type
 11        2462        2483.5        63.1         PEAK       1000    74.0       10.9      BE
 11        2462        2483.5        44.5           AV       1000    54.0        9.5      BE



 WLAN n-Mode; 20 MHz; 72.2 Mbit/s

         Channel                                                               Margin
          Center                  Spurious                                        to
 Ch.    Frequency    Frequency      Level                   RBW      Limit      Limit    Limit
 No.      [MHz]        [MHz]       [dBm]         Detector   [kHz]   [dBm]       [dB]     Type
 11        2462        2483.5        63.8         PEAK       1000    74.0       10.2      BE
 11        2462        2483.5        45.6           AV       1000    54.0        8.4      BE




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                      Page 19 of 32


 BT 1-DH1; 1 Mbit/s

            Channel                                                                                             Margin
             Center                                  Spurious                                                      to
 Ch.       Frequency           Frequency               Level                        RBW           Limit          Limit          Limit
 No.         [MHz]               [MHz]                [dBm]        Detector         [kHz]       [dBµV/m]         [dB]           Type
 78           2462               2483.5                 49.9        PEAK             1000          74.0          24.1            BE
 78           2462               2483.5                 37.6          AV             1000          54.0          16.4            BE



 BT 2-DH1; 2 Mbit/s

            Channel                                                                                             Margin
             Center                                  Spurious                                                      to
 Ch.       Frequency           Frequency               Level                        RBW           Limit          Limit          Limit
 No.         [MHz]               [MHz]                [dBm]        Detector         [kHz]       [dBµV/m]         [dB]           Type
 78           2462               2483.5                 49.5        PEAK             1000          74.0          24.5            BE
 78           2462               2483.5                 37.7          AV             1000          54.0          16.3            BE



 BT 3-DH1; 3 Mbit/s

            Channel                                                                                             Margin
             Center                                  Spurious                                                      to
 Ch.       Frequency           Frequency               Level                        RBW           Limit          Limit          Limit
 No.         [MHz]               [MHz]                [dBm]        Detector         [kHz]       [dBµV/m]         [dB]           Type
 78           2462               2483.5                 50.0        PEAK             1000          74.0          24.0            BE
 78           2462               2483.5                 37.7          AV             1000          54.0          16.3            BE




3.2.3.2         Measurement Plot (showing the highest value, “worst case”)

 M ar k er :                       2. 4835          G   Hz                 63. 81      d Bµ V/ m
 De lt a M k :                                           0   Hz          - 18. 17      dB


  L e v e l [ d Bµ V/ m        ]
80


70


60


50


40


30


20


10


  0
      2. 48G               2. 485G                           2. 49G                  2. 495G                  2. 5G
                                                  Fr e q u e n c y [ Hz ]

      M    ES     DA T _   1   4   0   5   _   039_pr e  PK
      M    ES     DA T _   1   4   0   5   _   039_pr e  AV
      LI   M      F CC     1   5   .   2   0   9 3m                  F ie ld   St r e n g t h   A V L im it
      LI   M      F CC     1   5   .   2   0   9 3m   Pe a k         F ie ld   St r e n g t h   Q - Pe a k     L im   it




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                                             Page 20 of 32


4      Test Equipment
List of Used Test Equipment


    The calibration, hardware and software states are shown for the testing period.


    Test Equipment Anechoic Chamber
     Lab ID:                    Lab 2
     Manufacturer:              Frankonia
     Description:               Anechoic Chamber for radiated testing
     Type:                      10.58x6.38x6.00 m³
                                Calibration Details                                      Last Execution    Next Exec.
                                NSA (FCC)                                                2014/01/09       2017/01/09

     Single Devices for Anechoic Chamber
       Single Device Name       Type                                     Serial Number   Manufacturer

       Air compressor           none                                     -               Atlas Copco

       Anechoic Chamber         10.58 x 6.38 x 6.00 m³                   none            Frankonia
                                Calibration Details                                      Last Execution    Next Exec.
                                FCC listing 96716 3m Part15/18                           2014/01/09       2017/01/08

       Controller Maturo        MCU                                      961208          Maturo GmbH

       EMC camera               CE-CAM/1                                 -               CE-SYS

       EMC camera Nr.2          CCD-400E                                 0005033         Mitsubishi

       Filter ISDN              B84312-C110-E1                                           Siemens&Matsushita

       Filter Universal 1A      BB4312-C30-H3                            -               Siemens&Matsushita


    Test Equipment Auxiliary Equipment for Conducted emissions
     Lab ID:                    Lab 1
     Manufacturer:              Rohde & Schwarz GmbH & Co.KG
     Description:               EMI Conducted Auxiliary Equipment

     Single Devices for Auxiliary Equipment for Conducted emissions
       Single Device Name       Type                                     Serial Number   Manufacturer

       AC Power Source          Chroma 6404                              64040001304     Chroma ATE INC.

       Cable "LISN to ESI"      RG214                                    W18.03+W48.03   Huber&Suhner

       Impedance Stabilization ISN T800                                  36159           Teseq GmbH
       Network
                               Calibration Details                                       Last Execution    Next Exec.
                                Standard Calibration                                     2014/02/06       2016/02/28

       Impedance Stabilization ISN/CDN ENY41                             100002          Rohde & Schwarz GmbH & Co.
       Network, Coupling                                                                 KG
       Decoupling Network

                                Calibration Details                                      Last Execution    Next Exec.
                                Standard calibration                                     2013/03/01       2015/03/31

       Impedance Stabilization ISN/CDN ST08                              36292           Teseq GmbH
       Network, Coupling
       Decoupling Network

                                Calibration Details                                      Last Execution    Next Exec.
                                Standard calibration                                     2014/01/10       2016/01/31




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                        Page 21 of 32


    Single Devices for Auxiliary Equipment for Conducted emissions (continued)
     Single Device Name    Type                         Serial Number   Manufacturer
     Impedance Stabilization ISN/CDN T8-Cat6            32187           Teseq GmbH
     Network, Coupling
     Decoupling Network

                           Calibration Details                          Last Execution    Next Exec.
                           Standard Calibration                         2014/01/08       2016/01/31

     One-Line V-Network    ESH 3-Z6                     100489          Rohde & Schwarz GmbH & Co.
                                                                        KG
                           Calibration Details                          Last Execution Next Exec.
                           standard calibration                         2014/06/18       2017/11/30

     One-Line V-Network    ESH 3-Z6                     100570          Rohde & Schwarz GmbH & Co.
                                                                        KG
                           Calibration Details                          Last Execution Next Exec.
                           Standard Calibration                         2013/11/25       2016/11/24

     Two-Line V-Network    ESH 3-Z5                     828304/029      Rohde & Schwarz GmbH & Co.
                                                                        KG
                           Calibration Details                          Last Execution Next Exec.
                           Standart Calibration                         2013/03/01       2015/02/28

     Two-Line V-Network    ESH 3-Z5                     829996/002      Rohde & Schwarz GmbH & Co.
                                                                        KG
                           Calibration Details                          Last Execution Next Exec.
                           Standard Calibration                         2013/03/01       2015/02/28




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                    Page 22 of 32


   Test Equipment Auxiliary Equipment for Radiated emissions
    Lab ID:                Lab 2
    Description:           Equipment for emission measurements
    Serial Number:         see single devices

    Single Devices for Auxiliary Equipment for Radiated emissions
     Single Device Name    Type                                  Serial Number    Manufacturer

     Antenna mast          AM 4.0                                AM4.0/180/119205 Maturo GmbH
                                                                 13

     Biconical Broadband   SBA 9119                              9119-005         Schwarzbeck
     Antenna

     Biconical dipole      VUBA 9117                             9117-108         Schwarzbeck
                           Calibration Details                                    Last Execution    Next Exec.
                           Standard Calibration                                   2012/01/18       2015/01/17

     Broadband Amplifier   JS4-18002600-32-5P                    849785           Miteq
     18MHz-26GHz

     Broadband Amplifier   AFS4-01000400-1Q-10P-4                -                Miteq
     1GHz-4GHz

     Broadband Amplifier   JS4-00101800-35-5P                    896037           Miteq
     30MHz-18GHz

     Cable "ESI to EMI     EcoFlex10                             W18.01-2+W38.01- Kabel Kusch
     Antenna"                                                    2

     Cable "ESI to Horn    UFB311A+UFB293C                       W18.02-2+W38.02- Rosenberger Micro-Coax
     Antenna"                                                    2

     Double-ridged horn    HF 906                                357357/001       Rohde & Schwarz GmbH & Co.
                                                                                  KG
                           Calibration Details                                    Last Execution Next Exec.
                           Standard Calibration                                   2012/05/18       2015/05/17

     Double-ridged horn    HF 906                                357357/002       Rohde & Schwarz GmbH & Co.
                                                                                  KG
                           Calibration Details                                    Last Execution Next Exec.
                           Standard Calibration                                   2012/06/26       2015/06/25

     High Pass Filter      4HC1600/12750-1.5-KK                  9942011          Trilithic

     High Pass Filter      5HC2700/12750-1.5-KK                  9942012          Trilithic

     High Pass Filter      5HC3500/12750-1.2-KK                  200035008        Trilithic

     High Pass Filter      WHKX 7.0/18G-8SS                      09               Wainwright

     Horn Antenna          BBHA 9170
     Schwarzbeck 15-26 GHz
     BBHA 9170

     Log.-per. Antenna     HL 562 Ultralog                       100609           Rohde & Schwarz GmbH & Co.
                                                                                  KG
                           Calibration Details                                    Last Execution Next Exec.
                           Standard Calibration                                   2012/12/18       2015/12/17

     Log.-per. Antenna     HL 562 Ultralog                       830547/003       Rohde & Schwarz GmbH & Co.
                                                                                  KG

     Loop Antenna          HFH2-Z2                               829324/006       Rohde & Schwarz GmbH & Co.
                                                                                  KG
                           Calibration Details                                    Last Execution Next Exec.
                           Standard calibration                                   2011/10/27       2014/10/26

     Pyramidal Horn Antenna 3160-09                              00083069         EMCO Elektronik GmbH
     26,5 GHz

     Pyramidal Horn Antenna 3160-10                              00086675         EMCO Elektronik GmbH
     40 GHz

Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                Page 23 of 32


    Single Devices for Auxiliary Equipment for Radiated emissions (continued)
     Single Device Name       Type                                    Serial Number   Manufacturer

     Tilt device Maturo       Antrieb TD1.5-10kg                      TD1.5-           Maturo GmbH
     (Rohacell)                                                       10kg/024/3790709



   Test Equipment Auxiliary Test Equipment
    Lab ID:                   Lab 2, Lab 3
    Manufacturer:             see single devices
    Description:              Single Devices for various Test Equipment
    Type:                     various
    Serial Number:            none

    Single Devices for Auxiliary Test Equipment
     Single Device Name       Type                                    Serial Number   Manufacturer

     AC Power Source          Chroma 6404                             64040001304     Chroma ATE INC.

     Broadband Power Divider 1506A / 93459                            LM390           Weinschel Associates
     N (Aux)

     Broadband Power Divider WA1515                                   A855            Weinschel Associates
     SMA

     Digital Multimeter 03    Fluke 177                               86670383        Fluke Europe B.V.
     (Multimeter)
                              Calibration Details                                     Last Execution    Next Exec.
                              Customized calibration                                  2013/12/04       2015/12/03

     Fibre optic link Satellite FO RS232 Link                         181-018         Pontis
     (Aux)

     Fibre optic link         FO RS232 Link                           182-018         Pontis
     Transceiver (Aux)

     Isolating Transformer    LTS 604                                 1888            Thalheimer
                                                                                      Transformatorenwerke GmbH


     Notch Filter Ultra Stable WRCA800/960-6EEK                       24              Wainwright
     (Aux)

     Signal Analyzer          FSV30                                   103005          Rohde & Schwarz GmbH & Co.
                                                                                      KG
                              Calibration Details                                     Last Execution Next Exec.
                              Standard                                                2014/02/10       2016/02/09

     Spectrum Analyser        FSP3                                    836722/011      Rohde & Schwarz GmbH & Co.
                                                                                      KG
                              Calibration Details                                     Last Execution Next Exec.
                              Standard                                                2012/06/13       2015/06/12

     Spectrum Analyser        FSU26                                   200418          Rohde & Schwarz GmbH &
                                                                                      Co.KG
                              Calibration Details                                     Last Execution Next Exec.
                              Standard calibration                                    2013/07/29       2014/07/28

     Vector Signal Generator SMIQ 03B                                 832492/061      Rohde & Schwarz GmbH &
                                                                                      Co.KG




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                  Page 24 of 32


   Test Equipment Digital Signalling Devices
    Lab ID:                    Lab 1, Lab 2, Lab 3
    Description:               Signalling equipment for various wireless technologies.

    Single Devices for Digital Signalling Devices
     Single Device Name        Type                                     Serial Number    Manufacturer

     Bluetooth Signalling Unit CBT                                      100589           Rohde & Schwarz GmbH & Co.
     CBT                                                                                 KG
                               Calibration Details                                       Last Execution Next Exec.
                               Standard calibration                                      2011/11/24      2014/11/23

     CMW500                    CMW500                                   107500           Rohde & Schwarz GmbH &
                                                                                         Co.KG
                               Calibration Details                                       Last Execution Next Exec.
                               Standard calibration                                      2014/01/27      2016/01/26

     Digital Radio             CMD 55                                   831050/020       Rohde & Schwarz GmbH & Co.
     Communication Tester                                                                KG
                               Calibration Details                                       Last Execution Next Exec.
                               Standard calibration                                      2011/11/28      2014/11/27

     Universal Radio           CMU 200                                  102366           Rohde & Schwarz GmbH & Co.
     Communication Tester                                                                KG
                               HW/SW Status                                              Date of Start Date of End
                               Hardware:                                                 2007/07/16
                               B11, B21V14, B21-2, B41, B52V14, B52-2,
                               B53-2, B56V14, B68 3v04, PCMCIA, U65V04
                               Software:
                               K21 4v21, K22 4v21, K23 4v21, K24 4v21, K42     4v21,
                               K43 4v21, K53 4v21, K56 4v22, K57 4v22, K58     4v22,
                               K59 4v22, K61 4v22, K62 4v22, K63 4v22, K64     4v22,
                               K65 4v22, K66 4v22, K67 4v22, K68 4v22, K69     4v22
                               Firmware:
                               µP1 8v50 02.05.06
                               ---

     Universal Radio           CMU 200                                  837983/052       Rohde & Schwarz GmbH & Co.
     Communication Tester                                                                KG
                               Calibration Details                                       Last Execution Next Exec.
                               Standard calibration                                      2011/12/07      2014/12/06
                               HW/SW Status                                              Date of Start    Date of End
                               HW options:                                               2007/01/02
                               B11, B21V14, B21-2, B41, B52V14, B52-2,    B53-2,
                               B54V14, B56V14, B68 3v04, B95, PCMCIA,     U65V02
                               SW options:
                               K21 4v11, K22 4v11, K23 4v11, K24 4v11,    K27 4v10,
                               K28 4v10, K42 4v11, K43 4v11, K53 4v10,    K65 4v10,
                               K66 4v10, K68 4v10,
                               Firmware:
                               µP1 8v40 01.12.05
                               ---
                               SW:                                                       2008/11/03
                               K62, K69

     Vector Signal Generator SMU200A                                    100912           Rohde & Schwarz GmbH & Co.
                                                                                         KG




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                     Page 25 of 32


   Test Equipment Emission measurement devices
    Lab ID:                  Lab 1, Lab 2
    Description:             Equipment for emission measurements
    Serial Number:           see single devices

    Single Devices for Emission measurement devices
     Single Device Name      Type                                   Serial Number   Manufacturer

     Personal Computer       Dell                                   30304832059     Dell

     Power Meter             NRVD                                   828110/016      Rohde & Schwarz GmbH &
                                                                                    Co.KG
                             Calibration Details                                    Last Execution Next Exec.
                             Standard calibration                                   2014/05/13       2015/05/12

     Sensor Head A           NRV-Z1                                 827753/005      Rohde & Schwarz GmbH &
                                                                                    Co.KG
                             Calibration Details                                    Last Execution Next Exec.
                             Standard calibration                                   2014/05/13       2015/05/12

     Signal Generator        SMR 20                                 846834/008      Rohde & Schwarz GmbH & Co.
                                                                                    KG

     Spectrum Analyzer       ESIB 26                                830482/004      Rohde & Schwarz GmbH & Co.
                                                                                    KG
                             Calibration Details                                    Last Execution Next Exec.
                             Standard Calibration                                   2014/01/07       2016/01/31
                             HW/SW Status                                           Date of Start     Date of End
                             Firmware-Update 4.34.4 from 3.45 during calibration    2009/12/03


   Test Equipment Multimeter 12
    Lab ID:                  Lab 4, Lab 5
    Description:             Ex-Tech 520
    Serial Number:           05157876

    Single Devices for Multimeter 12
     Single Device Name      Type                                   Serial Number   Manufacturer

     Digital Multimeter 12   EX520                                  05157876        Extech Instruments Corp.
     (Multimeter)
                             Calibration Details                                    Last Execution    Next Exec.
                             Customized calibration                                 2013/12/04       2015/12/03




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                Page 26 of 32


   Test Equipment Radio Lab Test Equipment
    Lab ID:                 Lab 3
    Description:            Radio Lab Test Equipment

    Single Devices for Radio Lab Test Equipment
     Single Device Name     Type                       Serial Number   Manufacturer

     Broadband Power Divider WA1515                    A856            Weinschel Associates
     SMA

     Coax Attenuator 10dB   4T-10                      F9401           Weinschel Associates
     SMA 2W

     Coax Attenuator 10dB   56-10                      W3702           Weinschel Associates
     SMA 2W

     Coax Attenuator 10dB   56-10                      W3711           Weinschel Associates
     SMA 2W

     Coax Cable             Sucotest 2,0m                              Huber&Suhner
     Huber&Suhner

     Coax Cable Rosenberger FA210A0010003030           54491-2         Rosenberger Micro-Coax
     Micro Coax
     FA210A0010003030
     SMA/SMA 1,0m


     Power Meter            NRVD                       828110/016      Rohde & Schwarz GmbH &
                                                                       Co.KG
                            Calibration Details                        Last Execution Next Exec.
                            Standard calibration                       2014/05/13       2015/05/12

     RF Step Attenuator RSP RSP                        833695/001      Rohde & Schwarz GmbH &
                                                                       Co.KG

     Rubidium Frequency     Datum, Model: MFS          5489/001        Datum-Beverly
     Standard
                            Calibration Details                        Last Execution    Next Exec.
                            Standard calibration                       2013/06/24       2014/07/02
                            Standard calibration                       2014/07/03       2015/07/02

     Sensor Head A          NRV-Z1                     827753/005      Rohde & Schwarz GmbH &
                                                                       Co.KG
                            Calibration Details                        Last Execution Next Exec.
                            Standard calibration                       2014/05/13       2015/05/12

     Signal Generator SME   SME03                      827460/016      Rohde & Schwarz GmbH &
                                                                       Co.KG
                            Calibration Details                        Last Execution Next Exec.
                            Standard calibration                       2011/11/25       2014/11/24

     Signal Generator SMP   SMP02                      836402/008      Rohde & Schwarz GmbH & Co.
                                                                       KG
                            Calibration Details                        Last Execution Next Exec.
                            Standard calibration                       2013/05/06       2016/05/05

     Spectrum Analyser      FSIQ26                     840061/005      Rohde & Schwarz GmbH & Co.
                                                                       KG
                            Calibration Details                        Last Execution Next Exec.
                            Standard Calibration                       2013/02/12       2015/02/11




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                   Page 27 of 32


   Test Equipment Regulatory Bluetooth RF Test Solution
    Lab ID:                    Lab 4
    Description:               Regulatory Bluetooth RF Tests
    Type:                      Bluetooth RF
    Serial Number:             001

    Single Devices for Regulatory Bluetooth RF Test Solution
     Single Device Name        Type                                  Serial Number   Manufacturer

     ADU 200 Relay Box 7       Relay Box                             A04380          Ontrak Control Systems Inc.

     Bluetooth Signalling Unit CBT                                   100302          Rohde & Schwarz GmbH &
     CBT                                                                             Co.KG
                               Calibration Details                                   Last Execution Next Exec.
                               Standard calibration                                  2013/08/28       2014/08/27

     Power Meter NRVD          NRVD                                  832025/059
                               Calibration Details                                   Last Execution    Next Exec.
                               Standard calibration                                  2013/08/26       2014/08/25

     Power Sensor NRV Z1 A PROBE                                     832279/013

                               Calibration Details                                   Last Execution    Next Exec.
                               Standard calibration                                  2013/08/28       2014/08/27

     Power Supply              NGSM 32/10                            2725
                               Calibration Details                                   Last Execution    Next Exec.
                               Standard calibration                                  2013/06/20       2015/06/19

     Rubidium Frequency        Datum MFS                             002             Datum GmbH
     Normal MFS
                               Calibration Details                                   Last Execution    Next Exec.
                               Standard calibration                                  2013/08/27       2014/08/26

     Signal Analyser FSIQ26 1119.6001.26                             832695/007      Rohde & Schwarz GmbH &
                                                                                     Co.KG

     Vector Signal Generator SMIQ03B                                 832870/017
     SMIQ03B
                             Calibration Details                                     Last Execution    Next Exec.
                               Standard calibration                                  2013/06/21       2016/06/20


   Test Equipment Shielded Room 02
    Lab ID:                    Lab 1
    Manufacturer:              Frankonia
    Description:               Shielded Room for conducted testing
    Type:                      12 qm
    Serial Number:             none


   Test Equipment Shielded Room 07
    Lab ID:                    Lab 4, Lab 5
    Description:               Shielded Room 4m x 6m




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                 Page 28 of 32


   Test Equipment T/A Logger 13
    Lab ID:                 Lab 1, Lab 2, Lab 3
    Description:            Lufft Opus10 TPR
    Type:                   Opus10 TPR
    Serial Number:          13936

    Single Devices for T/A Logger 13
     Single Device Name     Type                     Serial Number   Manufacturer

     ThermoAirpressure       Opus10 TPR (8253.00)    13936           Lufft Mess- und Regeltechnik
     Datalogger 13 (Environ)                                         GmbH

                            Calibration Details                      Last Execution    Next Exec.
                            Customized calibration                   2013/02/07       2015/02/06


   Test Equipment T/H Logger 02
    Lab ID:                 Lab 1
    Description:            Lufft Opus10
    Serial Number:          7489

    Single Devices for T/H Logger 02
     Single Device Name     Type                     Serial Number   Manufacturer

     ThermoHygro Datalogger Opus10 THI (8152.00)     7489            Lufft Mess- und Regeltechnik
     02 (Environ)                                                    GmbH

                            Calibration Details                      Last Execution    Next Exec.
                            Customized calibration                   2013/02/07       2015/02/06


   Test Equipment T/H Logger 03
    Lab ID:                 Lab 3
    Description:            Lufft Opus10
    Serial Number:          7482

    Single Devices for T/H Logger 03
     Single Device Name     Type                     Serial Number   Manufacturer

     ThermoHygro Datalogger Opus10 THI (8152.00)     7482            Lufft Mess- und Regeltechnik
     03 (Environ)                                                    GmbH

                            Calibration Details                      Last Execution    Next Exec.
                            Customized calibration                   2013/02/07       2015/02/06


   Test Equipment T/H Logger 12
    Lab ID:                 Lab 2
    Description:            Lufft Opus10
    Serial Number:          12482

    Single Devices for T/H Logger 12
     Single Device Name     Type                     Serial Number   Manufacturer

     ThermoHygro Datalogger Opus10 THI (8152.00)     12482           Lufft Mess- und Regeltechnik
     12 (Environ)                                                    GmbH

                            Calibration Details                      Last Execution    Next Exec.
                            Customized calibration                   2013/01/07       2015/01/06




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                 Page 29 of 32


   Test Equipment T/H Logger 15
    Lab ID:                Lab 4, Lab 5
    Description:           Lufft Opus10
    Serial Number:         13985

    Single Devices for T/H Logger 15
     Single Device Name    Type                             Serial Number    Manufacturer

     ThermoHygro Datalogger Opus10 THI (8152.00)            13985            Lufft Mess- und Regeltechnik
     15 (Environ)                                                            GmbH

                           Calibration Details                               Last Execution    Next Exec.
                           Customized calibration                            2013/01/07       2015/01/06


   Test Equipment Temperature Chamber 01
    Lab ID:                Lab 4, Lab 5
    Manufacturer:          see single devices
    Description:           Temperature Chamber KWP 120/70
    Type:                  Weiss
    Serial Number:         see single devices

    Single Devices for Temperature Chamber 01
     Single Device Name    Type                             Serial Number    Manufacturer

     Temperature Chamber   KWP 120/70                       59226012190010   Weiss Umwelttechnik GmbH
     Weiss 01
                           Calibration Details                               Last Execution    Next Exec.
                           Customized calibration                            2014/03/12       2016/03/11


   Test Equipment Temperature Chamber 05
    Lab ID:                Lab 3
    Manufacturer:          see single devices
    Description:           Temperature Chamber VT4002
    Type:                  Vötsch
    Serial Number:         see single devices

    Single Devices for Temperature Chamber 05
     Single Device Name    Type                             Serial Number    Manufacturer

     Temperature Chamber   VT 4002                          58566080550010   Vötsch
     Vötsch 05
                           Calibration Details                               Last Execution    Next Exec.
                           Customized calibration                            2014/03/11       2016/03/10




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                         Page 30 of 32


   Test Equipment WLAN RF Test Solution
    Lab ID:                   Lab 5
    Manufacturer:             7 layers AG
    Description:              Regulatory WLAN RF Tests
    Type:                     WLAN RF
    Serial Number:            001

    Single Devices for WLAN RF Test Solution
     Single Device Name       Type                                 Serial Number   Manufacturer

     Arbitrary Waveform       TGA12101                             284482
     Generator

     Power Meter NRVD         NRVD                                 832025/059
                              Calibration Details                                  Last Execution    Next Exec.
                              Standard calibration                                 2013/08/26       2014/08/25

     Power Sensor NRV Z1 A PROBE                                   832279/013

                              Calibration Details                                  Last Execution    Next Exec.
                              Standard calibration                                 2013/08/28       2014/08/27

     Power Supply             NGSM 32/10                           2725
                              Calibration Details                                  Last Execution    Next Exec.
                              Standard calibration                                 2013/06/20       2015/06/19

     Rubidium Frequency       Datum MFS                            002             Datum GmbH
     Normal MFS
                              Calibration Details                                  Last Execution    Next Exec.
                              Standard calibration                                 2013/08/27       2014/08/26

     Signal Analyser FSIQ26 1119.6001.26                           832695/007      Rohde & Schwarz GmbH &
                                                                                   Co.KG

     Spectrum Analyser        FSU26                                100136          Rohde & Schwarz GmbH &
                                                                                   Co.KG
                              Calibration Details                                  Last Execution Next Exec.
                              Standard Calibration                                 2014/01/06       2015/01/05
                              HW/SW Status                                         Date of Start     Date of End
                              FSU FW Update to v4.61 SP3, K5 v4.60 and K73 v4.61   2011/12/05

     Spectrum Analyser        FSU3                                 200046          Rohde & Schwarz GmbH &
                                                                                   Co.KG
                              Calibration Details                                  Last Execution Next Exec.
                              Standard calibration                                 2013/06/20       2014/06/19
                              HW/SW Status                                         Date of Start     Date of End
                              Firmware Version 4.51 SP1                            2011/12/07
                              Option FS-K72 4.50 SP1
                              Option FS-K73 4.50 SP1

     TOCT Switching Unit      Switching Unit                       040107          7 layers, Inc.

     Vector Signal Generator SMIQ03B                               832870/017
     SMIQ03B
                             Calibration Details                                   Last Execution    Next Exec.
                              Standard calibration                                 2013/06/21       2016/06/20




Test report Reference: MDE_DATA_1405_FCCi_Rev1                                                Page 31 of 32


5     Photo Report

Please refer to external report.




6     Setup Drawings




Drawing 1: Setup in the Anechoic chamber. For measurements below 1 GHz the ground
           was replaced by a conducting groundplane.




Test report Reference: MDE_DATA_1405_FCCi_Rev1                         Page 32 of 32