test report e

FCC ID: U4GFX3P

Test Report

Download: PDF
FCCID_2374988

   Final Report on
   Datalogic FALCONX3+ model 24
   FCC ID: U4GFX3P
   IC: 3862E-FX3P
   Report Reference:                       MDE_DATA_1405_FCCe

                                           acc. Title 47 CFR chapter I part 15 subpart B, Class B
   Date:                                   August 12, 2014
Test Laboratory:
7Layers AG
Borsigstr. 11
40880 Ratingen
Germany
Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7Layers AG                                         Aufsichtsratsvorsitzenderh                   Registergerichth registered in:
Borsigstrasse 11                                   Chairman of the Supervisory Board:           Düsseldorf, HRB 44096
40880 Ratingen, Germany                            Peter Mertel                                 USt-IdNr h VAT No.:
Phone: +49 (0) 2102 749 0                          Vorstandh Board:                             DE 203159652
Fax: +49 (0) 2102 749 350                          Dr. H.-J. Meckelburg                         TAX No. 147/5869/0385
www.7Layers.com                                    Dr. H. Ansorge


layers
                                                                                     Reference: MDE_DATA_1405_FCCe

                                                                   acc. Title 47 CFR chapter I part 15 subpart B, Class B


1         Administrative Data
1.1       Project Data

    Project Responsible:                                   Patrick Menge
    Date Of Test Report:                                   2014/08/12
    Date of first test:                                    2014/04/10
    Date of last test:                                     2014/06/06

1.2       Applicant Data
    Company Name:              Datalogic ADC S.r.1.
       Street:                Via S. Vitalino, 13
                              Lippo di Calderara di Reno
       City:                  40012 Bologna

    Contact Person:            Mr. Davide E. Vaccaneo
       Function:              Regulatory Engineer
       Department:            Regulatory & Reliability
       Phone:                 +39 051 314 72 16
       Fax:                   +39 051 314 75 61
       E—Mail:                davide.vaccaneo@datalogic.com



1.3       Test Laboratory Data
The following list shows all places and laboratories involved for test result generation:

    7 layers DE
       Company Name :                        7 layers AG
          Street :                           Borsigstrasse 11
          City :                             40880 Ratingen
          Country :                          Germany
       Contact Person :                      Mr. Michael Albert
          Phone :                            +49 2102 749 201
          Fax :                              +49 2102 749 444
          E Mail :                           Michael.Albert@7Layers.com

      Laboratory Details
        Lab ID       Identification          Responsible             Accreditation Info

        Lab 1        Radiated Emissions      Mr. Marco Kullik         DAkkS—Registration no. D—PL—12140—01—01
                                             Mr. Robert Machulec


1.4       Signature of the Testing Responsible




      Patrick Lomax
      responsible for tests performed in: Lab 1




                                                                                                           Page 2 of 25


7layers
                                                                                                            Reference: MDE_DATA_1405 FCCe

                                                                                          acc. Title 47 CFR chapter I part 15 subpart B, Class B


  1.5       Signature of the Accreditation Responsible




            _/v»-\)     /-\\        ;       7            '-3   "~ x :/        A       |

            (, 2      W        w#
                                        /
                                        /
                                                     I<
                                                     |
                                                                12E 7 i‘
                                                               {% L
                                                                          h
                                                                      p4i /1
             s
             \‘ "
                      XiaA/
                       y °l 14          m       =~
                                                                                  C
         Accreditation scope responsible person
         responsible for Lab 1




 2          Test Object Data
 2.1        General OUT Description
  The following section lists all OUTs (Object‘s Under Test) involved during testing.

     QOUT: Dataiogic FALCONX3+

        Type / Model / Family:                                        Datalogic FALCONX3+ model 24
                                                                      FCC ID: U4GFX3P
                                                                      IC: 3862E—FX3P
        Product Category:                                             Handheld Device
        Manufacturer:
         Company Name:                                                Datalogic ADC S.r.i.
         Street:                                                      Via San Vitalino, 13
         City:                                                        40012 Lippo di Calderara di Reno
         Country:                                                     Italy
         Company URL:                                                 http://www.datalogic.com

         Contact Person:                                              Mr. Davide Vaccaneo
            Function:                                                 Regulatory Engineer
            Phone:                                                    +39 051 314 72 16
            Fax:                                                      +39 051 314 75 61
            E—Mail:                                                   davide.vaccaneo@datalogic.com

        Parameter List:

         Parameter name                                               Value
         Parameter for Scope FCC_v2:
         AC Power Supply                                              120 V / 60 Hz




                                                                                                                                                5
                                                                                                                                   Page 3 0
                                                                                                                                           TA
                                                                                                                                           N


                                                                   Reference: MDE_DATA_1405_FCCe

                                                 acc. Title 47 CFR chapter I part 15 subpart B, Class B


2.2     Detailed Description of OUT Samples

  Sample : ac01

      OUT Identifier                 Datalogic FALCONX3+
      Sample Description             2DLongRange;Alpha;WEHH;VGA;Camer
      Serial No.                     24G
      HW Status                      P/N: 945250066
      SW Status                      1.88 and subsequent
      Low Voltage                    3.5 V              Low Temp.               0 °C
      High Voltage                   4.2 V              High Temp.              +40 °C
      Nominal Voltage                3.7 V              Normal Temp.            +20 °C


      Parameter List:

        Parameter Description        Value

        Parameter for Scope FCC_v2
        Frequency_high               2480    (MHz)
        Frequency_low                2402    (MHz)
        Frequency_mid                2441    (MHz)



  Sample : ag02

      OUT Identifier                 Datalogic FALCONX3+
      Sample Description             2DLongRange;Alpha;WEHH;VGA;Camer
      Serial No.                     24NEW
      HW Status                      P/N: 945250066
      SW Status                      1.88 and subsequent
      Date of Receipt                2014/04/11
      Low Voltage                    3.5 V              Low Temp.               0 °C
      High Voltage                   4.2 V              High Temp.              +40 °C
      Nominal Voltage                3.7 V              Normal Temp.            +20 °C


      Parameter List:

        Parameter Description        Value

        Parameter for Scope FCC_v2
        Frequency_high               2480    (MHz)
        Frequency_low                2402    (MHz)
        Frequency_mid                2441    (MHz)




                                                                                          Page 4 of 25


                                                                             Reference: MDE_DATA_1405_FCCe

                                                           acc. Title 47 CFR chapter I part 15 subpart B, Class B


2.3         OUT Features

  Features for OUT:       Datalogic FALCONX3+
       Designation Description                                    Allowed Values          Supported Value(s)

       Features for scope: FCC_v2
       AC           The OUT is powered by or connected to AC
                    Mains
       BT           EUT supports Bluetooth data rate of 1 Mbps
                    with GFSK modulation in the band 2400 MHz -
                    2483.5 MHz
       DC           The OUT is powered by or connected to DC
       EDR2         EUT supports Bluetooth using data rate of 2
                    Mbps with PI/4 DQPSK modulation in the band
                    2400 MHz - 2483.5 MHz
       EDR3         EUT supports Bluetooth using data rate of 3
                    Mbps with 8DPSK modulation in the band 2400
                    MHz - 2483.5 MHz
       Iant         Integral Antenna: permanent fixed antenna,
                    which may be built-in, designed as an
                    indispensable part of the equipment
       TantC        temporary antenna connector, which may be
                    only built-in for testing, designed as an
                    example part of the equipment
       Wb           EUT supports WLAN in mode b in the band
                    2400 MHz - 2483.5 MHz
       Wg           EUT supports WLAN in mode g in the band
                    2400 MHz - 2483.5 MHz
       WLAN         EUT supports WLAN channels 2412 MHz - 2462
                    MHz.
       Wn           EUT supports WLAN in mode n in the band
                    2400 MHz - 2483.5 MHz


2.4         Auxiliary Equipment

  AE No.          Type Designation      Serial No.        HW Status        SW Status        Description
  AE AE01         BT-26                 TW13072718                                          Battery
  AE AE94         Cherry RS6000         G 0000273 2P28                                      Keyboard
  AE AE92         Fujitsu Siemens       A30638114250                                        AC Adapter laptop
                  0335C2065
  AE AE91         Fujitsu Siemens       YK2H014267                                          Laptop
                  Amilo Pro V3205
  AE AE90         LG Flatron L1740BQ    509WANF1W607                                        TFT Display
  AE AE93         Logitech MBB48        LZC90505478                                         Mouse
  AE AE02         P/N 94A051970                                                             Cable USB
                                                                                            Handylink Client
  AE AE03         VXI                   W081121901                                          Headset



2.5         Operating Mode(s)

  Ref.-No.       Description

  08             BT TX 2441 MHz, WLAN TX 2437 MHz, USB traffic, Scanner active;
  09             WLAN TX on 2437MHz, BT on standby, video recording




                                                                                                      Page 5 of 25


                                                                                     Reference: MDE_DATA_1405_FCCe

                                                                acc. Title 47 CFR chapter I part 15 subpart B, Class B


2.6        Setups used for Testing
    For each setup a relation is given to determine if and which samples and auxiliary equipment is used.
    The left side list all OUT samples and the right side lists all auxiliary equipment for the given setup.

    Setup No.   List of OUT samples                             List of auxiliary equipment
        Sample No.               Sample Description             AE No.           AE Description

    AH01       (Different Display Type / Keypad (computer peripheral))

        Sample: ac01               2DLongRange;Alpha;WEH        AE AE01         Battery
                                   H;VGA;Camer
                                                                AE AE94         Keyboard

                                                                AE AE92         AC Adapter laptop

                                                                AE AE91         Laptop

                                                                AE AE90         TFT Display

                                                                AE AE93         Mouse

                                                                AE AE02         Cable USB Handylink Client

    AJ01       (Camera & Headset)

        Sample: ag02               2DLongRange;Alpha;WEH        AE AE01         Battery
                                   H;VGA;Camer
                                                                AE AE03         Headset


3          Results
3.1        General

       Documentation of tested                   Available at the test laboratory.
       devices:

       Interpretation of the                     The results of the inspection are described on the following
       test results:                             pages, where 'Conformity' or 'Passed' means that the
                                                 certification criteria were verified and that the tested device is
                                                 conform to the applied standard.

                                                 In cases where 'Declaration' is printed, the required documents
                                                 are available in the manufacturers product documentation.

                                                 In cases where 'not applicable' is printed, the test case
                                                 requirements are not relevant to the specific equipment
                                                 implementation.


       Note:                                     The environmental conditions are recorded and available in the
                                                 InterLab system for each performed test.


3.2        List of the Applicable Body

       (Body for Scope: FCC_v2)

           Designation                           Description
           FCC47CFRChIPART15bRADIO               Part 15, Subpart B - Unintentional Radiators
           FREQUENCY DEVICES




                                                                                                           Page 6 of 25


                                                                       Reference: MDE_DATA_1405_FCCe

                                                     acc. Title 47 CFR chapter I part 15 subpart B, Class B


3.3   List of Test Specification
      Test Specification:   FCC part 2 and 15
      Version               10-1-13 Edition
      Title:                PART 2 - GENERAL RULES AND REGULATIONS
                            PART 15 - RADIO FREQUENCY DEVICES




                                                                                              Page 7 of 25


                                                                       Reference: MDE_DATA_1405_FCCe

                                                     acc. Title 47 CFR chapter I part 15 subpart B, Class B


3.4     Summary
Test Case Identifier / Name                                                        Lab
 Test (condition)                           Result               Date of Test      Ref.        Setup

15b.2 Spurious Radiated Emissions §15.109
 15b.2; Mode = generating a high power      Passed               2014/06/06       Lab 1         AJ01
 consumption
                                            operating mode: 09
                                            Passed           2014/04/10           Lab 1         AH01
                                            operating mode: 08




                                                                                              Page 8 of 25


                                                                     Reference: MDE_DATA_1405_FCCe

                                                   acc. Title 47 CFR chapter I part 15 subpart B, Class B


3.5        Detailed Results
3.5.1         15b.2 Spurious Radiated Emissions §15.109

Test1: 15b.2; Mode = generating a high power consumption
 Result:                      Passed

 Setup No.:                   AH01

 Date of Test:                2014/04/10 22:00

 Body:                        FCC47CFRChIPART15bRADIO FREQUENCY DEVICES

 Test Specification:           FCC part 2 and 15




                                                                                            Page 9 of 25


                                                                              Reference: MDE_DATA_1405_FCCe

                                                            acc. Title 47 CFR chapter I part 15 subpart B, Class B

Detailed Results:
EMI RADIATED TEST



EUT:                   (DE1006002ab01 Setup AG01)
Manufacturer:          Datalogic
Operating Condition:   BT TX 2441 MHz, WLAN TX 2437 MHz, USB traffic, Scanner active; 120V/60Hz
Test Site:             7 layers, Ratingen
Operator:              ASO
Test Specification:    FCC part 15 b; Class B
Comment:               Horizontal EUT position
Start of Test:         10.04.2014 / 19:09:05


SCAN TABLE: "FCC part 15 b"

    Short Description:               FCC part 15 b
    Start      Stop       Step          Detector Meas.      IF      Transducer
    Frequency Frequency   Width                    Time     Bandw.
    30.0 MHz   1.0 GHz    60.0 kHz      MaxPeak    1.0 ms   120 kHz HL562




    Level [dBµV/m]
 80


 70


 60


 50


 40
                                                                 x
                                                                 xxxx
 30


 20

                                                  x
 10


    0
        30M    50M     70M    100M         200M             300M        500M 700M 1G
                                Frequency [Hz]

x       MES DAT_1405_028_fin QP
        MES DAT_1405_028_pre PK
        LIM FCC part 15 b  Field Strength QP Limit




                                                                                                   Page 10 of 25


                                                                                 Reference: MDE_DATA_1405_FCCe

                                                               acc. Title 47 CFR chapter I part 15 subpart B, Class B
 MEASUREMENT RESULT: "DAT_1405_028_fin QP"

 10.04.2014 20:05
    Frequency   Level          Transd     Limit   Margin    Height   Azimuth   Polarisation
          MHz  dBµV/m              dB    dBµV/m       dB        cm       deg

   180.000000          11.60      8.6      43.5     31.9     225.0     19.00   HORIZONTAL
   342.420000          35.60     14.2      46.0     10.4     100.0    338.00   HORIZONTAL
   343.080000          35.70     14.2      46.0     10.3     125.0    338.00   HORIZONTAL
   345.120000          31.80     14.3      46.0     14.2     134.0     20.00   HORIZONTAL
   345.840000          33.20     14.3      46.0     12.8     103.0    336.00   HORIZONTAL
   346.380000          32.40     14.3      46.0     13.6     118.0    292.00   HORIZONTAL
   346.860000          33.00     14.3      46.0     13.0     100.0    325.00   HORIZONTAL
   347.940000          32.30     14.3      46.0     13.7     113.0    334.00   HORIZONTAL
   349.980000          30.40     14.4      46.0     15.6     125.0    292.00   HORIZONTAL
   350.340000          30.40     14.4      46.0     15.6     120.0    337.00   HORIZONTAL



Test2: 15b.2; Mode = generating a high power consumption
 Result:                                Passed

 Setup No.:                             AJ01

 Date of Test:                          2014/06/06 10:21

 Body:                                  FCC47CFRChIPART15bRADIO FREQUENCY DEVICES

 Test Specification:                    FCC part 2 and 15




                                                                                                      Page 11 of 25


                                                                                Reference: MDE_DATA_1405_FCCe

                                                              acc. Title 47 CFR chapter I part 15 subpart B, Class B

Detailed Results:
EMI RADIATED TEST


EUT:                   (DE1006002ag02)
Manufacturer:          Datalogic
Operating Condition:   WLAN TX on 2437MHz, BT on standby, video recording
Test Site:             7 layers, Ratingen
Operator:              URO
Test Specification:    FCC part 15 Class B 120V / 60Hz
Comment:               Horizontal + vertical antenna polarisation
Start of Test:         06.06.2014 / 10:21:44


SCAN TABLE: "EN 55022 Field"

    Short Description:            EN 55022 Field Strength
    Start      Stop       Step       Detector Meas.     IF      Transducer
    Frequency Frequency   Width                Time     Bandw.
    30.0 MHz   1.0 GHz    60.0 kHz   MaxPeak   1.0 ms   120 kHz HL562



    Level [dBµV/m]
 80


 70


 60


 50


 40                                                                                  x


 30


 20


 10


    0
        30M      50M      70M      100M             200M        300M         500M        700M   1G
                                      Frequency [Hz]

x       MES DAT_1405_054_fin QP
        MES DAT_1405_054_pre PK
        LIM FCC part 15 b   Field Strength QP Limit


MEASUREMENT RESULT: "DAT_1405_054_fin QP"

06.06.2014 11:41
   Frequency   Level      Transd    Limit   Margin   Height   Azimuth   Polarisation
         MHz  dBµV/m          dB   dBµV/m       dB       cm       deg

    575.280000    39.60    19.8      46.0      6.4   136.0    201.00    HORIZONTAL




                                                                                                     Page 12 of 25


                                                                                 Reference: MDE_DATA_1405_FCCe

                                                               acc. Title 47 CFR chapter I part 15 subpart B, Class B


4         Test Equipment Details
4.1       List of Used Test Equipment

    The calibration, hardware and software states are shown for the testing period.


    Test Equipment Anechoic Chamber
      Lab ID:                 Lab 1
      Manufacturer:           Frankonia
      Description:            Anechoic Chamber for radiated testing
      Type:                   10.58x6.38x6.00 m³
                              Calibration Details                                      Last Execution Next Exec.
                              NSA (FCC)                                                2014/01/09     2017/01/09

      Single Devices for Anechoic Chamber
       Single Device Name     Type                                  Serial Number      Manufacturer

       Air compressor         none                                  -                  Atlas Copco
       Anechoic Chamber       10.58 x 6.38 x 6.00 m³                  none             Frankonia
                              Calibration Details                                      Last Execution Next Exec.
                              FCC listing 96716 3m Part15/18                           2014/01/09     2017/01/08

       Controller Maturo      MCU                                   961208             Maturo GmbH
       EMC camera             CE-CAM/1                                -                CE-SYS
       EMC camera Nr.2        CCD-400E                                0005033          Mitsubishi
       Filter ISDN            B84312-C110-E1                                           Siemens&Matsushita
       Filter Universal 1A    BB4312-C30-H3                           -                Siemens&Matsushita




                                                                                                      Page 13 of 25


                                                                        Reference: MDE_DATA_1405_FCCe

                                                      acc. Title 47 CFR chapter I part 15 subpart B, Class B


Test Equipment Auxiliary Equipment for Radiated emissions
 Lab ID:                Lab 1
 Description:           Equipment for emission measurements
 Serial Number:         see single devices

 Single Devices for Auxiliary Equipment for Radiated emissions
  Single Device Name    Type                              Serial Number       Manufacturer

  Antenna mast          AM 4.0                            AM4.0/180/11920 Maturo GmbH
                                                          513
  Biconical Broadband   SBA 9119                          9119-005            Schwarzbeck
  Antenna
                        Calibration Details                                   Last Execution Next Exec.
                        Standard Calibration                                  2009/06/04     2014/06/03

  Biconical dipole      VUBA 9117                         9117-108            Schwarzbeck
                        Calibration Details                                   Last Execution Next Exec.
                        Standard Calibration                                  2012/01/18     2015/01/17

  Broadband Amplifier   JS4-18002600-32-5P                849785              Miteq
  18MHz-26GHz
  Broadband Amplifier   AFS4-01000400-1Q-10P-4            -                   Miteq
  1GHz-4GHz
  Broadband Amplifier   JS4-00101800-35-5P                896037              Miteq
  30MHz-18GHz
  Cable "ESI to EMI     EcoFlex10                         W18.01-             Kabel Kusch
  Antenna"                                                2+W38.01-2
  Cable "ESI to Horn    UFB311A+UFB293C                   W18.02-             Rosenberger Micro-Coax
  Antenna"                                                2+W38.02-2
  Double-ridged horn    HF 906                            357357/001          Rohde & Schwarz GmbH &
                                                                              Co. KG
                        Calibration Details                                   Last Execution Next Exec.
                        Standard Calibration                                  2012/05/18     2015/05/17

  Double-ridged horn    HF 906                            357357/002          Rohde & Schwarz GmbH &
                                                                              Co. KG
                        Calibration Details                                   Last Execution Next Exec.
                        Standard Calibration                                  2012/06/26     2015/06/25

  High Pass Filter      4HC1600/12750-1.5-KK              9942011             Trilithic
  High Pass Filter      5HC2700/12750-1.5-KK              9942012             Trilithic
  High Pass Filter      5HC3500/12750-1.2-KK              200035008           Trilithic
  High Pass Filter      WHKX 7.0/18G-8SS                  09                  Wainwright
  Horn Antenna          BBHA 9170
  Schwarzbeck 15-26
  GHz BBHA 9170
  Log.-per. Antenna     HL 562 Ultralog                   100609              Rohde & Schwarz GmbH &
                                                                              Co. KG
                        Calibration Details                                   Last Execution Next Exec.
                        Standard Calibration                                  2012/12/18     2015/12/17

  Log.-per. Antenna     HL 562 Ultralog                   830547/003          Rohde & Schwarz GmbH &
                                                                              Co. KG
  Loop Antenna          HFH2-Z2                           829324/006          Rohde & Schwarz GmbH &
                                                                              Co. KG
                        Calibration Details                                   Last Execution Next Exec.
                        Standard calibration                                  2011/10/27     2014/10/26


                                                                                             Page 14 of 25


                                                                            Reference: MDE_DATA_1405_FCCe

                                                          acc. Title 47 CFR chapter I part 15 subpart B, Class B

 Single Devices for Auxiliary Equipment for Radiated emissions (continued)
  Single Device Name      Type                                 Serial Number      Manufacturer

  Pyramidal Horn          3160-09                              00083069           EMCO Elektronik GmbH
  Antenna 26,5 GHz
  Pyramidal Horn          3160-10                              00086675           EMCO Elektronik GmbH
  Antenna 40 GHz
  Tilt device Maturo      Antrieb TD1.5-10kg                   TD1.5-          Maturo GmbH
  (Rohacell)                                                   10kg/024/379070
                                                               9


Test Equipment Auxiliary Test Equipment
 Lab ID:                  Lab 1
 Manufacturer:            see single devices
 Description:             Single Devices for various Test Equipment
 Type:                    various
 Serial Number:           none

 Single Devices for Auxiliary Test Equipment
  Single Device Name      Type                                 Serial Number      Manufacturer

  Broadband Power         1506A / 93459                        LM390              Weinschel Associates
  Divider N (Aux)
  Broadband Power         WA1515                               A855               Weinschel Associates
  Divider SMA
  Digital Multimeter 03   Fluke 177                            86670383           Fluke Europe B.V.
  (Multimeter)
                          Calibration Details                                     Last Execution Next Exec.
                          Customized calibration                                  2013/12/04     2015/12/03

  Fibre optic link        FO RS232 Link                        181-018            Pontis
  Satellite (Aux)
  Fibre optic link        FO RS232 Link                        182-018            Pontis
  Transceiver (Aux)
  Isolating Transformer   LTS 604                              1888               Thalheimer
                                                                                  Transformatorenwerke
                                                                                  GmbH
  Notch Filter Ultra      WRCA800/960-6EEK                     24                 Wainwright
  Stable (Aux)
  Signal Analyzer         FSV30                                103005             Rohde & Schwarz GmbH &
                                                                                  Co. KG
                          Calibration Details                                     Last Execution Next Exec.
                          Standard                                                2014/02/10     2016/02/09

  Spectrum Analyser       FSP3                                 836722/011         Rohde & Schwarz GmbH &
                                                                                  Co. KG
                          Calibration Details                                     Last Execution Next Exec.
                          Standard                                                2012/06/13     2015/06/12

  Spectrum Analyser       FSU26                                200418             Rohde & Schwarz GmbH &
                                                                                  Co.KG
                          Calibration Details                                     Last Execution Next Exec.
                          Standard calibration                                    2013/07/29     2014/07/28

  Vector Signal           SMIQ 03B                             832492/061         Rohde & Schwarz GmbH &
  Generator                                                                       Co.KG




                                                                                                 Page 15 of 25


                                                                            Reference: MDE_DATA_1405_FCCe

                                                          acc. Title 47 CFR chapter I part 15 subpart B, Class B


Test Equipment Digital Signalling Devices
 Lab ID:                 Lab 1
 Description:            Signalling equipment for various wireless technologies.

 Single Devices for Digital Signalling Devices
  Single Device Name     Type                                  Serial Number       Manufacturer

  Bluetooth Signalling   CBT                                   100589              Rohde & Schwarz GmbH &
  Unit CBT                                                                         Co. KG
                         Calibration Details                                       Last Execution Next Exec.
                         Standard calibration                                      2011/11/24     2014/11/23

  CMW500                 CMW500                                107500              Rohde & Schwarz GmbH &
                                                                                   Co.KG
                         Calibration Details                                       Last Execution Next Exec.
                         Standard calibration                                      2014/01/27     2016/01/26

  Digital Radio        CMD 55                                  831050/020          Rohde & Schwarz GmbH &
  Communication Tester                                                             Co. KG
                       Calibration Details                                         Last Execution Next Exec.
                         Standard calibration                                      2011/11/28     2014/11/27

  Universal Radio      CMU 200                                 102366              Rohde & Schwarz GmbH &
  Communication Tester                                                             Co. KG
                       HW/SW Status                                                Date of Start Date of End
                         Hardware:                                                 2007/07/16
                         B11, B21V14, B21-2, B41, B52V14, B52-2,
                         B53-2, B56V14, B68 3v04, PCMCIA, U65V04
                         Software:
                         K21 4v21, K22 4v21, K23 4v21, K24 4v21, K42     4v21,
                         K43 4v21, K53 4v21, K56 4v22, K57 4v22, K58     4v22,
                         K59 4v22, K61 4v22, K62 4v22, K63 4v22, K64     4v22,
                         K65 4v22, K66 4v22, K67 4v22, K68 4v22, K69     4v22
                         Firmware:
                         µP1 8v50 02.05.06
                         ---
  Universal Radio      CMU 200                                 837983/052          Rohde & Schwarz GmbH &
  Communication Tester                                                             Co. KG
                       Calibration Details                                         Last Execution Next Exec.
                         Standard calibration                                      2011/12/07 2014/12/06
                         HW/SW Status                                              Date of Start Date of End
                         HW options:                                               2007/01/02
                         B11, B21V14, B21-2, B41, B52V14, B52-2,     B53-2,
                         B54V14, B56V14, B68 3v04, B95, PCMCIA,      U65V02
                         SW options:
                         K21 4v11, K22 4v11, K23 4v11, K24 4v11,     K27 4v10,
                         K28 4v10, K42 4v11, K43 4v11, K53 4v10,     K65 4v10,
                         K66 4v10, K68 4v10,
                         Firmware:
                         µP1 8v40 01.12.05
                         ---
                         SW:                                                       2008/11/03
                         K62, K69
  Vector Signal          SMU200A                               100912              Rohde & Schwarz GmbH &
  Generator                                                                        Co. KG




                                                                                                  Page 16 of 25


                                                                         Reference: MDE_DATA_1405_FCCe

                                                       acc. Title 47 CFR chapter I part 15 subpart B, Class B


Test Equipment Emission measurement devices
 Lab ID:               Lab 1
 Description:          Equipment for emission measurements
 Serial Number:        see single devices

 Single Devices for Emission measurement devices
  Single Device Name   Type                                Serial Number       Manufacturer

  Personal Computer    Dell                                30304832059         Dell
  Power Meter          NRVD                                828110/016          Rohde & Schwarz GmbH &
                                                                               Co.KG
                       Calibration Details                                     Last Execution Next Exec.
                       Standard calibration                                    2013/05/03     2014/05/02
                       Standard calibration                                    2014/05/13     2015/05/12

  Sensor Head A        NRV-Z1                              827753/005          Rohde & Schwarz GmbH &
                                                                               Co.KG
                       Calibration Details                                     Last Execution Next Exec.
                       Standard calibration                                    2013/04/30     2014/04/29
                       Standard calibration                                    2014/05/13     2015/05/12

  Signal Generator     SMR 20                              846834/008          Rohde & Schwarz GmbH &
                                                                               Co. KG
                       Calibration Details                                     Last Execution Next Exec.
                       standard calibration                                    2011/05/12     2014/05/11

  Spectrum Analyzer    ESIB 26                             830482/004          Rohde & Schwarz GmbH &
                                                                               Co. KG
                       Calibration Details                                     Last Execution Next Exec.
                       Standard Calibration                                    2014/01/07 2016/01/31
                       HW/SW Status                                            Date of Start Date of End
                       Firmware-Update 4.34.4 from 3.45 during calibration     2009/12/03


Test Equipment T/A Logger 13
 Lab ID:               Lab 1
 Description:          Lufft Opus10 TPR
 Type:                 Opus10 TPR
 Serial Number:        13936

 Single Devices for T/A Logger 13
  Single Device Name   Type                                Serial Number       Manufacturer

  ThermoAirpressure    Opus10 TPR (8253.00)                13936               Lufft Mess- und
  Datalogger 13                                                                Regeltechnik GmbH
  (Environ)
                       Calibration Details                                     Last Execution Next Exec.
                       Customized calibration                                  2013/02/07     2015/02/06




                                                                                              Page 17 of 25


                                                                  Reference: MDE_DATA_1405_FCCe

                                                acc. Title 47 CFR chapter I part 15 subpart B, Class B


Test Equipment T/H Logger 12
 Lab ID:               Lab 1
 Description:          Lufft Opus10
 Serial Number:        12482

 Single Devices for T/H Logger 12
  Single Device Name   Type                         Serial Number       Manufacturer

  ThermoHygro          Opus10 THI (8152.00)         12482               Lufft Mess- und
  Datalogger 12                                                         Regeltechnik GmbH
  (Environ)
                       Calibration Details                              Last Execution Next Exec.
                       Customized calibration                           2013/01/07     2015/01/06




                                                                                       Page 18 of 25


                                                            Reference: MDE_DATA_1405_FCCe

                                          acc. Title 47 CFR chapter I part 15 subpart B, Class B


5     Annex
5.1   Additional Information for Report




                                                                                 Page 19 of 25


                                                                                Reference: MDE_DATA_1405_FCCe

                                                            acc. Title 47 CFR chapter I part 15 subpart B, Class B
Test Description
_____________
_____________



_______________________________

Conducted emissions (AC power line)
_______________________________

Standard       FCC Part 15 Subpart B

The test was performed according to: ANSI C 63.4, 2009

Test Description
The test set-up was made in accordance to the general provisions of ANSI C 63.4-2009.
The Equipment Under Test (EUT) was setup in a shielded room to perform the conducted emissions
measurements in a typical installation configuration. The EUT was powered from 50µH || 50 Ohm Line
Impedance Stabilization Network (LISN) which meets the requirements of ANSI C63.4–2009, Annex B, in the
frequency range of the measurements. The LISN’s unused connections were terminated with 50 Ohm loads.

The measurement procedure consists of two steps. It is implemented into the EMI test software ES-K1 from
R&S.

Step 1: Preliminary scan
Intention of this step is, to determine the conducted EMI-profile of the EUT.
EMI receiver settings:
- Detector: Peak - Maxhold
- Frequency range: 150 kHz – 30 MHz
- Frequency steps: 5 kHz
- IF–Bandwidth: 9 kHz
- Measuring time / Frequency step: 20 ms
- Measurement on phase + neutral lines of the power cords

On basis of this preliminary scan the highest amplitudes and the corresponding frequencies relative to the
limit are identified. Emissions above the limit and emissions which are in the 10 dB range below the limit are
considered.

Step 2: Final measurement
Intention of this step is, to determine the highest emissions with the settings defined in the test specification
for the frequencies identified in step 1.
EMI receiver settings:
- Detector: Quasi-Peak
- IF - Bandwidth: 9 kHz
- Measuring time: 1 s / frequency

At   each frequency determined in step 1, four measurements are performed in the following combinations:
1)   Neutral lead - reference ground (PE grounded)
2)   Phase lead - reference ground (PE grounded)
3)   Neutral lead - reference ground (PE floating)
4)   Phase lead - reference ground (PE floating)

The highest value is reported.


Test Requirements / Limits

If not stated within the measurement plot and/or test result, class B limits are applied.

FCC Part 15, Subpart B, §15.107, Class B Limit

Frequency Range (MHz)      QP Limit (dBµV)        AV Limit (dBµV)
0.15 – 0.5                 66 to 56               56 to 46
0.5 – 5                    56                     46
5 – 30                     60                     50




                                                                                                      Page 20 of 25


                                                                             Reference: MDE_DATA_1405_FCCe

                                                           acc. Title 47 CFR chapter I part 15 subpart B, Class B



FCC Part 15, Subpart B, §15.107, Class A Limit

Frequency Range (MHz)     QP Limit (dBµV)        AV Limit (dBµV)
0.15 - 0.5                79                     66
0.5 - 30                  73                     60

Used conversion factor: Limit (dBµV) = 20 log (Limit (µV)/1µV).

NOTES:
A missing result table in the corresponding test report section means, that no final measurement was
performed because no relevant frequencies (peaks) were found in the preliminary scan.
The chosen operating mode is selected as representative mode to generate “worst-case” conditions, i.e. high
power consumption.



_______________________

Spurious radiated emissions
_______________________

Standard     FCC Part 15, Subpart B

The test was performed according to: ANSI C 63.4, 2009

Test Description

Measurement below 1 GHz:
The test set-up was made in accordance to the general provisions of ANSI C 63.4-2009.
The Equipment Under Test (EUT) was set up on a non-conductive table 1.0 x 2.0 m in the semi-anechoic
chamber. The influence of the EUT support table that is used between 30–1000 MHz was evaluated.
The test was performed at the distance of 3 m between the EUT and the receiving antenna. The
measurement procedure is implemented into the EMI test software ES-K1 from R&S. The radiated emissions
measurements were made in a typical installation configuration. Exploratory tests are performed at 3
orthogonal axes to determine the worst-case orientation of a body-worn or handheld EUT. The final test on all
kind of EUTs is performed at 2 axes. A pre-check is also performed while the EUT is powered from both AC
and DC (battery) power in order to find the worst-case operating condition.

Step 1: Preliminary scan (test to identify the highest amplitudes relative to the limit)
Intention of this step is, to determine the radiated EMI-profile of the EUT.
Settings for step 1:
- Detector: Peak-Maxhold
- Frequency range: 30 – 1000 MHz
- Frequency steps: 60 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 µs
- Turntable angle range: –180° to +180°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
On basis of this preliminary scan the highest amplitudes and the corresponding frequencies relative to the
limit are identified. Emissions above the limit and emissions which are in the 10 dB range below the limit are
considered.

Step 2:
A further measurement will be performed on the frequencies determined in step 1. Intention of this step is,
to find out the approximate turntable angle and antenna height for each frequency.
Settings for step 2:
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –180° to +180°
- Turntable step size: 45°
- Height variation range: 1 – 4 m

                                                                                                   Page 21 of 25


                                                                              Reference: MDE_DATA_1405_FCCe

                                                           acc. Title 47 CFR chapter I part 15 subpart B, Class B
- Height variation step size: 0.5 m
- Polarisation: horizontal + vertical
After this step the EMI test system has determined the following values for each frequency (of step 1):
- Frequency
- Azimuth value (of turntable)
- Antenna height
The last two values have now the following accuracy:
- Azimuth value (of turntable): 45°
- Antenna height: 0.5 m

Step 3: final measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is necessary to
find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be adjusted. The
turntable azimuth will be slowly varied by +/- 22.5° around this value. During this action the value of
emission is continuously measured. The turntable azimuth at the highest emission will be recorded and
adjusted. In this position the antenna height is also slowly varied by +/- 25 cm around the antenna height
determined. During this action the value of emission is also continuously measured. The antenna height of
the highest emission will also be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100ms
- Turntable angle range: –22.5° to +22.5° around the determined value
- Height variation range: -0.25 m to +0.25 m around the determined value

Step 4: Final measurement (with QP detector)
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak(< 1GHz)
- Measured frequencies: in step 3 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

Measurement above 1 GHz:
The following modifications apply to the measurement procedure for the frequency range above 1 GHz:
The measurement distance was reduced to 1 m. The results were extrapolated by the extrapolation factor of
20 dB/decade (inverse linear-distance for field strength measurements, inverse-linear-distance-squared for
the power density measurements). Due to the fact that in this frequency range a double ridged wave guided
horn antenna (up to 18 GHz) and a horn antenna (18–25 GHz) are used, the steps 2-4 as described before,
are omitted. Step 1 was performed at one height of the receiving antenna only.
Detector: Peak, Average (simultaneously)
RBW = VBW = 1 MHz; above 7 GHz 100 kHz


Test Requirements / Limits

If not stated within the measurement plot and/or test result, class B limits are applied.

FCC Part 15, Subpart B, §15.109, Radiated Emission Limits
Frequency Range (MHz): Class B Limit (dBµV/m)

Frequency Range (MHz)      Class B Limit (dBµV/m)
30 – 88                    40.0
88 – 216                   43.5
216 – 960                  46.0
above 960                  54.0

Frequency Range (MHz) Class A Limit (dBµV/m) / @ 3m !
30 - 88                49.5
88 - 216               54.0
216 - 960            56.9
above 960              60.0


§15.35(b)
..., there is also a limit on the radio frequency emissions, as measured using instrumentation with a peak
detector function, corresponding to 20 dB above the maximum permitted average limit....
Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)

                                                                                                   Page 22 of 25


                                                                            Reference: MDE_DATA_1405_FCCe

                                                          acc. Title 47 CFR chapter I part 15 subpart B, Class B


 NOTE: A missing result table in the corresponding test report section means, that no final measurement was
 performed because no relevant frequencies (peaks) were found in the preliminary scan.
_____________

Setup Drawings
_____________




Setup in the Anechoic chamber. For measurements below 1 GHz the ground was replaced
by a conducting ground plane.




                LISN                            Analyzer




                                                Signaling
                 EUT
                                                  UNIT

Setup in the shielded room for conducted measurements at AC mains port



                                                                                                 Page 23 of 25


                                                                  Reference: MDE_DATA_1405_FCCe

                                                acc. Title 47 CFR chapter I part 15 subpart B, Class B
___________________________________________________________

Correlation of measurement requirements from FCC and IC
___________________________________________________________



Measurement                   FCC reference                 IC reference
Conducted Emissions           §15.107                       ICES-003 Issue 5
(AC Power Line)
Radiated Spurious Emissions   §15.109                       ICES-003 Issue 5

Remarks:

1. FCC Part 15 subpart B, ICES 003 and CISPR 22 contain different definitions of Class A
   and Class B limits, i.e. which class is applicable to which kind of EUT.
   ICES 003 and CISPR 22 distinguish between the location where the EUT is intended to
   operate whilst FCC refers to the method of commercial distribution (distributive
   trades).
2. The correct assignment of the appropriate class to the concrete EUT is not scope of
   this test report!
3. A radio apparatus that is specifically subject to an Industry Canada Radio Standard
   Specification (RSS) and which contains an ITE is not subject to ICES-003 provided
   the ITE is used only to enable operation of the radio apparatus and the ITE does not
   control additional functions or capabilities.
4. ISM (Industrial, Scientific or Medical) radio frequency generators, though they may
   contain ITE, are excluded from the definition of ITE and are not subject to ICES-003.
   They are instead subject to the Interference-Causing Equipment Standard ICES-001,
   which specifically addresses ISM radio frequency generators.
5. The kind of EUT (ITE, ISM, Radio) determines which IC Standard is applicable.




                                                                                       Page 24 of 25


                                                                         Reference: MDE_DATA_1405_FCCe

                                                       acc. Title 47 CFR chapter I part 15 subpart B, Class B


6         Index
1 Administrative Data                                                                                    2

    1.1 Project Data                                                                                     2

    1.2 Applicant Data                                                                                   2

    1.3 Test Laboratory Data                                                                             2

    1.4 Signature of the Testing Responsible                                                             2

    1.5 Signature of the Accreditation Responsible                                                       3

2 Test Object Data                                                                                       3

    2.1 General OUT Description                                                                          3

    2.2 Detailed Description of OUT Samples                                                              4

    2.3 OUT Features                                                                                     5

    2.4 Auxiliary Equipment                                                                              5

    2.5 Operating Mode(s)                                                                                5

    2.6 Setups used for Testing                                                                          6

3 Results                                                                                                6

    3.1 General                                                                                          6

    3.2 List of the Applicable Body                                                                      6

    3.3 List of Test Specification                                                                       7

    3.4 Summary                                                                                          8

     3.5 Detailed Results                                                                                9

     3.5.1 15b.2 Spurious Radiated Emissions §15.109                                                     9

4 Test Equipment Details                                                                                13

    4.1 List of Used Test Equipment                                                                     13

5 Annex                                                                                                 19

    5.1 Additional Information for Report                                                               19

6 Index                                                                                                 25




                                                                                              Page 25 of 25



Document Created: 2014-08-12 15:30:38
Document Modified: 2014-08-12 15:30:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC