           Client : Datalogic S.r.l.
      Production : Smartphone
     Model Name : MEMOR 10

     Brand Name : Datalogic

         FCC ID : U4GDL35US

Hardware Version : V00 (US)

Software Version : 2.00.05.20190726

          Issued : 2019-10-29


                                                                 Report No.I19D00137-SRD06




                                             NOTE
1. The test results in this test report relate only to the devices specified in this report.
2. This report shall not be reproduced except in full without the written approval of
   East China Institute of Telecommunications.
3. KDB 971168 D01 has not been accredited by A2LA.
4. For the test results, the uncertainty of measurement is not taken into account when
   judging the compliance with specification, and the results of measurement or the
   average value of measurement results are taken as the criterion of the compliance
   with specification directly.




Test Laboratory:
East China Institute of Telecommunications
Add: 7-8F, G Area, No.668, Beijing East Road, Huangpu District, Shanghai, P. R. China
Tel: +86 21 63843300
FAX: +86 21 63843301
E-Mail: welcome@ecit.org.cn


East China Institute of Telecommunications                                   Page Number: 2 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                         Report Issued Date: Oct.29.2019


                                                              Report No.I19D00137-SRD06



                                        Revision Version
        Report Number               Revision      Date                  Memo
       I19D00137-SRD06                 00      2019-08-14    Initial creation of test report
       I19D00137-SRD06                 01      2019-10-29   Second creation of test report




East China Institute of Telecommunications                               Page Number: 3 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                     Report Issued Date: Oct.29.2019


                                                                                                             Report No.I19D00137-SRD06




                                                                CONTENTS
1.     TEST LABORATORY............................................................................................................................ 5

1.1.   TESTING LOCATION............................................................................................................................ 5

1.2.   TESTING ENVIRONMENT................................................................................................................... 5

1.3.   PROJECT DATA.................................................................................................................................... 5

1.4.   SIGNATURE............................................................................................................................................ 5

2.     CLIENT INFORMATION....................................................................................................................... 6

2.1.   APPLICANT INFORMATION...............................................................................................................6

2.2.   MANUFACTURER INFORMATION....................................................................................................6

3.     EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE)................................ 7

3.1.   ABOUT EUT............................................................................................................................................7

3.2.   INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST............................................ 7

3.3.   INTERNAL IDENTIFICATION OF AE USED DURING THE TEST............................................... 7

4.     REFERENCE DOCUMENTS................................................................................................................8

4.1.   REFERENCE DOCUMENTS FOR TESTING....................................................................................8

5.     TEST RESULTS......................................................................................................................................9

5.1.   SUMMARY OF TEST RESULTS......................................................................................................... 9

5.2.   STATEMENTS....................................................................................................................................... 11

6.     TEST EQUIPMENT UTILIZED...........................................................................................................12

7.     TEST ENVIRONMENT........................................................................................................................ 14

8.     MEASUREMENT UNCERTAINTY.................................................................................................... 15

ANNEX A.             MEASUREMENT RESULTS..............................................................................................16

ANNEX A.1.           OUTPUT POWER................................................................................................................ 16

ANNEX A.2.           EMISSION LIMT...................................................................................................................21

ANNEX B. ACCREDITATION CERTIFICATE........................................................................................... 24
 East China Institute of Telecommunications                                                                              Page Number: 4 of 24
 TEL: +86 21 63843300 FAX: +86 21 63843301                                                                    Report Issued Date: Oct.29.2019


                                                                       Report No.I19D00137-SRD06



Test Laboratory

1.1. Testing Location

 Company Name               ECIT Shanghai, East China Institute of Telecommunications
 Address                    7-8/F., Area G, No.668, Beijing East Road, Shanghai, China
 Postal Code                200001
 Telephone                  (+86)-021-63843300
 Fax                        (+86)-021-63843301
 FCC registration No        958356


1.2. Testing Environment

 Normal Temperature          15℃-35℃
 Relative Humidity           25%-75%


1.3. Project data

 Project Leader              Yu Anlu
 Testing Start Date          2019-06-22
 Testing End Date            2019-06-24


1.4. Signature




             Wang Liang                                                  Fan Songyan
       (Prepared this test report)                                 (Reviewed this test report)




                                         Zheng Zhongbin
                                     (Approved this test report)




East China Institute of Telecommunications                                        Page Number: 5 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                              Report Issued Date: Oct.29.2019


                                                                    Report No.I19D00137-SRD06



2. Client Information

2.1. Applicant Information

Company Name              Datalogic S.r.l.
Address                   Via San Vitalino no. 13, Calderara di Reno – 40012 (BO) - Italy
Telephone                 +39 051 314 72 16
Postcode                  /


2.2. Manufacturer Information

Company Name              Datalogic S.r.l.
Address                   Via San Vitalino no. 13, Calderara di Reno – 40012 (BO) - Italy
Telephone                 +39 051 314 72 16
Postcode                  /




East China Institute of Telecommunications                                      Page Number: 6 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                            Report Issued Date: Oct.29.2019


                                                                       Report No.I19D00137-SRD06



3. Equipment Under Test (EUT) and Ancillary Equipment (AE)
3.1. About EUT

 Production                           Smartphone
 Model name                           MEMOR 10
 LTE Frequency Band                   LTE2/4/5/7/12/13/17/25/26
 LTE CA Frequency Band                CA_4A_4A/CA_4C/CA_7A-7A/CA_7C(Downlink Only)
 Extreme Temperature                  -30/+50℃
 Nominal Voltage                      3.80V
 Extreme High Voltage                 4.35V
 Extreme Low Voltage                  3.60V
 Note:
a. Photographs of EUT are shown in ANNEX A of this test report.
b. The value of the antenna gain is provided by the customer. For specific antenna information,
   please check the antenna specifications of the customer.


3.2. Internal Identification of EUT used during the test

 EUT ID*      SN or IMEI              HW Version          SW Version                Date of receipt
 N01          359737090067954         V00 (US)            2.00.05.20190726          2019-06-18
 N03          359737090067947         V00 (US)            2.00.05.20190726          2019-06-18
*EUT ID: is used to identify the test sample in the lab internally.


3.3. Internal Identification of AE used during the test

 AE ID*          Description                                             SN
 AE1             RF cable                                                ---
*AE ID: is used to identify the test sample in the lab internally.




East China Institute of Telecommunications                                        Page Number: 7 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                              Report Issued Date: Oct.29.2019


                                                                      Report No.I19D00137-SRD06



4. Reference Documents

4.1. Reference Documents for testing
The following documents listed in this section are referred for testing.


      Reference                                      Title                                 Version
                         FREQUENCY ALLOCATIONS AND RADIO TREATY
      FCC Part 2                                                                         2018-10-01
                         MATTERS; GENERAL RULES AND REGULATIONS
     FCC Part 22         PUBLIC MOBILE SERVICES                                          2018-10-01
     FCC Part 24         PERSONAL COMMUNICATIONS SERVICES                                2018-10-01
                         MISCELLANEOUS WIRELESS COMMUNICATIONS
     FCC Part 27                                                                         2018-10-01
                         SERVICES
     FCC Part 90         PRIVATE LAND MOBILE RADIO SERVICES                              2018-10-01
                         Land Mobile FM or PM Communications Equipment
   ANSI/TIA-603-E                                                                           2016
                         Measurement and Performance Standards
                         American National Standard of Procedures for Compliance
     ANSI C63.26                                                                            2015
                         Testing of Licensed Transmitters Used in Licensed Radio
                         Measurement Guidance for Certification of Licensed Digital
   KDB 971168 D01                                                                          v03r01
                         Transmitters




East China Institute of Telecommunications                                        Page Number: 8 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                              Report Issued Date: Oct.29.2019


                                                                     Report No.I19D00137-SRD06



5. Test Results
5.1. Summary of Test Results
          LTE Band 2
                                                            Section in
                                                 FCC
            Items         Test Name                            this         Verdict
                                              Sub-clause
                                                             report
              1      Output Power            24.232(c)         A.1              P
                                             24.238(a),
              2      Emission Limit                            A.2              P
                                             2.1051
          LTE Band 4
                                                            Section in
                                                FCC
            Items         Test Name                            this         Verdict
                                             Sub-clause
                                                             report
              1      Output Power            27.50(d)(4)       A.1              P
                                             27.53(h),
              2      Emission Limit                            A.2              P
                                             2.1051
          LTE Band 5
                                                            Section in
                                                 FCC
            Items         Test Name                            this         Verdict
                                              Sub-clause
                                                             report
                                             §2.1046(a),
              1      Output Power                              A.1              P
                                             22.913(a)
                                             22.917,
              2      Emission Limit                            A.2              P
                                             2.1051
          LTE Band 7
                                                            Section in
                                                FCC
            Items         Test Name                            this         Verdict
                                             Sub-clause
                                                             report
              1      Output Power            27.50(h)(2)       A.1             P
                                             27.53(m),
              2      Emission Limit                            A.2             P
                                             2.1051
          LTE Band 12
                                                            Section in
                                                FCC
            Items         Test Name                            this         Verdict
                                             Sub-clause
                                                             report
               1     Output Power            27.50(c)(10)      A.1             P
                                             27.53(g),
               2     Emission Limit                            A.2             P
                                             2.1051



           LTE Band 13
                                                             Section in
                                                 FCC
             Items        Test Name                             this         Verdict
                                              Sub-clause
                                                              report
East China Institute of Telecommunications                                      Page Number: 9 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                            Report Issued Date: Oct.29.2019


                                                                          Report No.I19D00137-SRD06



                 1   Output Power            27.50(b)(10)           A.1              P
                                             27.53(c),
                 2   Emission Limit                                 A.2              P
                                             2.1051
           LTE Band 17
                                                              Section in
                                                 FCC
             Items         Test Name                             this             Verdict
                                              Sub-clause
                                                               report
                 1    Output Power           27.50(c)(10)        A.1                 P
                                             27.53(g),
                 2    Emission Limit                                A.2              P
                                             2.1051
           LTE Band 25
                                                              Section in
                                                 FCC
             Items         Test Name                             this             Verdict
                                              Sub-clause
                                                               report
                 1    Output Power           27.50(c)(10)        A.1                 P
                                             27.53(g),
                 2    Emission Limit                                A.2              P
                                             2.1051
          LTE Band 26
                                                              Section in
                                                 FCC
             Items        Test Name                              this            Verdict
                                              Sub-clause
                                                               report
                      Equivalent             2.1046/90.13
                 1    Isotropically          21                     A.1              P
                      Radiated Power
                      Peak EIRP Power        2.1046/90.13
                 2                                                  A.2              P
                      Density                21

           The following terms are used in the above table.
                     Pass,the EUT complies with the essential requirements in the
             P
                     standard.
             NM      Not measure, the test was not measured by ECIT.
             NA      Not applicable, the test was not applicable.
                     Fail, the EUT does not comply with the essential requirements in
             F
                     the standard.




East China Institute of Telecommunications                                           Page Number: 10 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                                 Report Issued Date: Oct.29.2019


                                                                      Report No.I19D00137-SRD06



5.2. Statements
The MEMOR 10,supporting GSM/WCDMA/LTE.etc,manufactured by Datalogic S.r.l. is a variant
product for testing.ECIT only performed test cases which identified with Pass/Fail/Inc result in
section 5.

ECIT has verified that the compliance of the tested device specified in section 3 of this test report
is successfully evaluated according to the procedure and test methods as defined in type
certification requirement listed in section 4 of this test report.

Note: This project is a variant of I18D00022-SRD06 original report. We only retest and report the
EIRP and radiation test data. For other information, please refer to the original report.




East China Institute of Telecommunications                                        Page Number: 11 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                              Report Issued Date: Oct.29.2019


                                                                    Report No.I19D00137-SRD06



6. Test Equipment Utilized

Climate chamber

  No.     Equipment         Model             SN     Manufacturer     Cal.date       Cal.interval

            Climate
   1                       SH-641       92012011       ESPEC         2017-12-25        2 years
            chamber



Radiated emission test system
The test equipment and ancillaries used are as follows.

  No.     Equipment         Model             SN     Manufacturer     Cal.date       Cal.interval

           Universal
            Radio
   1                      CMW500         104178           R&S        2019-05-10         1 year
         Communicatio
           n Tester

   2     Test Receiver      ESU40        100307           R&S        2019-05-10         1 year

           TRILOG
                          VULB916      VULB9163
   3      Broadband                                  Schwarzbeck     2017-02-25        3 years
                             3           -515
           Antenna

            Double
                           ETS-311
   4     Ridged Guide                    135890           ETS        2017-01-11        3 years
                              7
           Antenna

             2-Line
   5                       ENV216        101380           R&S        2019-05-10         1 year
           V-Network

         Substitution A    ETS-311
   6                                    00135890          ETS       2017-01-11         3 years
            ntenna            7

           RF Signal       SMF100
   7                                     102314           R&S        2019-05-10         1 year
           Generator         A

         Substitution A   VUBA911
   8                                    9117-266     Schwarzbeck     2017-11-18        3 years
            ntenna           7


   9        Amplifier       SCU08            10146        R&S        2019-05-10         1 year




East China Institute of Telecommunications                                     Page Number: 12 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                           Report Issued Date: Oct.29.2019


                                                                     Report No.I19D00137-SRD06



Conducted test system

  No.      Equipment          Model           SN      Manufacturer     Cal.date       Cal.interval


          Vector Signal
   1                         FSQ40           200063       R&S         2019-05-10         1 year
            Analyser

           Wireless
         communication
   2                        CMW500           148904       R&S         2019-05-10         1 year
         comprehensive
            tester

            DC Power        ZUP60-1      LOC-220Z
   3                                                  TDL-Lambda      2019-05-10         1 year
             Supply            4         006-0007



Software
                       Name                                            Version

          Eagle FCC LTE auto test system                                 V3.0

                       EMC32                                            V9.15




East China Institute of Telecommunications                                      Page Number: 13 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                            Report Issued Date: Oct.29.2019


                                                                  Report No.I19D00137-SRD06



7. Test Environment

Shielding Room1 (6.0 meters×3.0 meters×2.7 meters) did not exceed following limits along the
conducted RF performance testing:

              Temperature                                 Min. = 15 ℃, Max. = 35 ℃

            Relative humidity                              Min. = 20%, Max. = 75 %

         Shielding effectiveness                                      > 100 dB

       Ground system resistance                                         < 0.5

Control room did not exceed following limits along the EMC testing:

             Temperature                                   Min. = 15 ℃, Max. = 35 ℃

            Relative humidity                              Min. =25 %, Max. =75 %

       Shielding effectiveness                                > 100 dB

         Electrical insulation                                 > 10 k

       Ground system resistance                               < 0.5

Fully-anechoic chamber1 (6.9 meters×10.9 meters×5.4 meters) did not exceed following limits
along the EMC testing:

                Temperature                             Min. = 15 ℃, Max. = 35 ℃

              Relative humidity                          Min. = 25 %, Max. = 75 %

           Shielding effectiveness                               > 100 dB

             Electrical insulation                                    > 10 k

         Ground system resistance                                     < 0.5

                   VSWR                          Between 0 and 6 dB, from 1GHz to 18GHz

          Site Attenuation Deviation               Between -4 and 4 dB,30MHz to 1GHz

         Uniformity of field strength          Between 0 and 6 dB, from 80MHz to 3000 MHz




East China Institute of Telecommunications                                       Page Number: 14 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                             Report Issued Date: Oct.29.2019


                                                                  Report No.I19D00137-SRD06



8. Measurement Uncertainty
Measurement uncertainty for all the testing in this report are within the limit specified in ECIT
documents. The detailed measurement uncertainty to see the column, k=2
                                                               Confidence       Calculated
          Measurement Items                      Range
                                                                 Level          Uncertainty

    Maximum Peak Output Power                30MHz-3600MHz         95%          ±0.544dB

    EBW and VBW                              30MHz-3600MHz         95%          ±62.04Hz

    Transmitter Spurious
                                              30MHz-2GHz           95%           ±0.90dB
    Emission-Conducted
    Transmitter Spurious
                                              2GHz-3.6GHz          95%           ±0.88dB
    Emission-Conducted
    Transmitter Spurious
                                              3.6GHz-8GHz          95%           ±0.96dB
    Emission-Conducted
    Transmitter Spurious
                                              8GHz-20GHz           95%           ±0.94dB
    Emission-Conducted
    Transmitter Spurious
                                              9KHz-30MHz           95%           ±5.66dB
    Emission-Radiated
    Transmitter Spurious
                                             30MHz-1000MHz         95%           ±4.98dB
    Emission-Radiated
    Transmitter Spurious
                                        1000MHz -18000MHz          95%           ±5.06dB
    Emission-Radiated
    Transmitter Spurious
                                       18000MHz -40000MHz          95%           ±5.20dB
    Emission-Radiated
    Frequency stability                       1MHz-16GHz           95%          ±62.04Hz




East China Institute of Telecommunications                                    Page Number: 15 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                          Report Issued Date: Oct.29.2019


                                                                    Report No.I19D00137-SRD06



ANNEX A.          MEASUREMENT RESULTS

ANNEX A.1.        OUTPUT POWER

A.1.1. Summary
During the process of testing, the EUT was controlled via Rhode & Schwarz Digital Radio
Communication tester (CMW500) to ensure max power transmission and proper modulation.
In all cases, output power is within the specified limits.
CMW500 setting:
1: CMW500 is connected to the DUT
2; Set RX Expected PEP to 30 dbm

A.1.2 Radiated

A.1.2.1 Description
This is the test for the maximum radiated power from the EUT.
Rule Part 24.232(b) specifies, "Mobile/portable stations are limited to 2 watts e.i.r.p. Peak power"
and 24.232(c) specifies that "Peak transmit power must be measured over any interval of
continuous transmission using instrumentation calibrated in terms of an rms-equivalent voltage."
Rule Part 27.50(d) specifies “Fixed, mobile, and portable (handheld) stations operating in the
1710–1755 MHz band are limited to 1 watt EIRP”.
Rule Part 27.50(h)(2) specifies “Mobile stations are limited to 2.0 watts EIRP.”.
Rule Part 27.50(c) specifies “Portable stations (hand-held de-vices) are limited to 3 watts ERP.”.

A.1.2.2 Method of Measurement
The measurements procedures in TIA-603E-2016 are used.
1. EUT was placed on a 1.5 meter high non-conductive stand at a 3 meter test distance from the
    receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT
    for emission measurements. The height of receiving antenna is 1.5m. The test setup refers to
    figure below. Detected emissions were maximized at each frequency by rotating the EUT
    through 360° and adjusting the receiving antenna polarization. The radiated emission
    measurements of all transmit frequencies in three channels (High, Middle, Low) were
    measured with peak detector.




East China Institute of Telecommunications                                      Page Number: 16 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                            Report Issued Date: Oct.29.2019


                                                                      Report No.I19D00137-SRD06



2. The EUT is then put into continuously transmitting mode at its maximum power level during
   the test. And the maximum value of the receiver should be recorded as (Pr).
3. The EUT shall be replaced by a substitution antenna. The test setup refers to figure below.




   In the chamber, a substitution antenna for the frequency band of interest is placed at the
   reference point of the chamber. An RF signal source for the frequency band of interest is
   connected to the substitution antenna with a cable that has been constructed to not interfere
   with the radiation pattern of the antenna. A power (PMea) is applied to the input of the
   substitution antenna. Adjust the level of the signal generator output until the value of the
   receiver reaches the previously recorded (Pr). The power of signal source (PMea) is recorded.
   The test should be performed by rotating the test item and adjusting the receiving antenna
   polarization.
4. An amplifier should be connected to the Signal Source output port. And the cable should be
   connected between the amplifier and the substitution antenna.
   The cable loss (Pcl), the substitution antenna Gain (Ga) and the amplifier Gain (PAg) should be
   recorded after test.
   The measurement results are obtained as described below:
   Power (EIRP) = PMea + PAg - Pcl + Ga
5. This value is EIRP since the measurement is calibrated using an antenna of known gain (unit
   dBi) and known input power.
6. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP = EIRP -2.15.

A.1.2.3 Measurement result
LTE Band 2- EIRP 24. 232(b)
Limits: ≤33dBm (2W)
LTE Band 2_3MHz_QPSK
           Frequency                          EIRP            Limit
                                                                                  Polarization
             (MHz)                           (dBm)           (dBm)
             1908.5                          21.29           33.00                     H
LTE Band 2_20MHz_16QAM
           Frequency                          EIRP            Limit
                                                                                  Polarization
             (MHz)                           (dBm)           (dBm)
              1900                           21.97           33.00                      H

East China Institute of Telecommunications                                       Page Number: 17 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                             Report Issued Date: Oct.29.2019


                                                             Report No.I19D00137-SRD06



 LTE Band 4- EIRP 27.50(d)
Limits: ≤30m (1W)
LTE Band 4_20MHz_QPSK
          Frequency                       EIRP       Limit
                                                                         Polarization
            (MHz)                        (dBm)      (dBm)
             1720                        23.37      30.00                      H
LTE Band 4_3MHz_16QAM
          Frequency                       EIRP       Limit
                                                                         Polarization
            (MHz)                        (dBm)      (dBm)
            1711.5                       23.49      30.00                      H
LTE Band5-EIRP 27.50(d)
Limits: ≤33Bm (2W)
LTE Band 5_3MHz_QPSK
          Frequency                       EIRP       Limit
                                                                         Polarization
            (MHz)                        (dBm)      (dBm)
            825.50                       21.72      38.45                      H
LTE Band 5_3MHz_16QAM
          Frequency                       EIRP       Limit
                                                                          Polarization
            (MHz)                        (dBm)      (dBm)
            825.50                       21.69      38.45                      H
LTE Band 7- EIRP 27.50(h)(2)
Limits: ≤33 dBm (2W)
LTE Band 7_15MHz_QPSK
          Frequency                       EIRP       Limit
                                                                          Polarization
            (MHz)                        (dBm)      (dBm)
           2562.50                       23.34      33.00                      H
LTE Band 7_20MHz_16QAM
          Frequency                       EIRP       Limit
                                                                          Polarization
            (MHz)                        (dBm)      (dBm)
            2510.00                      24.59      33.00                      H
LTE Band 12 - EIRP 27.50(c)(10)
Limits: ≤34.77dBm (3W)
LTE Band 12_1.4MHz_QPSK
           Frequency                      EIRP       Limit
                                                                          Polarization
             (MHz)                       (dBm)      (dBm)
             715.30                          21.7   34.77                      H
LTE Band 12_1.4MHz_16QAM
          Frequency                       EIRP       Limit
                                                                          Polarization
            (MHz)                        (dBm)      (dBm)
            715.30                       21.89      34.77                      H
LTE Band 13 - EIRP 27.50(c)(10)
Limits: ≤34.77dBm (3W)
LTE Band 13_10MHz_QPSK
East China Institute of Telecommunications                              Page Number: 18 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                    Report Issued Date: Oct.29.2019


                                                           Report No.I19D00137-SRD06



          Frequency                      EIRP      Limit
                                                                        Polarization
            (MHz)                       (dBm)     (dBm)
              782                        20.28    34.77                      H
LTE Band 13_10MHz_16QAM
          Frequency                      EIRP      Limit
                                                                        Polarization
            (MHz)                       (dBm)     (dBm)
              782                        20.16    34.77                      H
LTE Band 17- EIRP 27.50(c)(10)
Limits: ≤34.77dBm (3W)
LTE Band 17_5MHz_QPSK
          Frequency                      EIRP     Limit
                                                                       Polarization
            (MHz)                       (dBm)    (dBm)
            713.50                      21.72    34.77                       H
LTE Band 17_5MHz_16QAM
          Frequency                     EIRP      Limit
                                                                       Polarization
            (MHz)                      (dBm)     (dBm)
            713.50                      21.68    34.77                       H




East China Institute of Telecommunications                            Page Number: 19 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                  Report Issued Date: Oct.29.2019


                                                                Report No.I19D00137-SRD06



LTE Band 25 - EIRP 27.50(c)(10)
Limits: ≤34.77dBm (3W)
LTE Band 25_3MHz_QPSK
           Frequency                      EIRP          Limit
                                                                              Polarization
             (MHz)                       (dBm)         (dBm)
             1913.5                      22.12         34.77                       H
LTE Band 25_3MHz_16QAM
          Frequency                      EIRP          Limit
                                                                             Polarization
            (MHz)                       (dBm)         (dBm)
            1913.5                       22.1         34.77                       H
LTE Band 26 - EIRP 27.50(c)(10)
Limits: ≤34.77dBm (3W)
LTE Band 26_3MHz_QPSK
          Frequency                       EIRP           Limit
                                                                              Polarization
            (MHz)                        (dBm)          (dBm)
             815.5                       22.53          34.77                      H
LTE Band 26_3MHz_16QAM
          Frequency                      EIRP           Limit
                                                                              Polarization
            (MHz)                       (dBm)          (dBm)
             815.5                       22.58          34.77                      H
ANALYZER SETTINGS:
RBW = VBW = 8MHz for occupied bandwdiths equal to or less than 5MHz.
RBW = VBW = 20MHz for occupied bandwidths equal to or greater than 10MHz.




East China Institute of Telecommunications                                  Page Number: 20 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                        Report Issued Date: Oct.29.2019


                                                                     Report No.I19D00137-SRD06



ANNEX A.2.        EMISSION LIMT
Reference
FCC: CFR 2.1051, 22.917,24.238(a), 27.53(g), 27.53(h) , 27.53(m).
A.2.1 Measurement Method
The measurements procedures in TIA-603E-2016 are used. This measurement is carried out in
fully-anechoic chamber FAC-3.
The spectrum was scanned from 30 MHz to the 10th harmonic of the highest frequency generated
within the equipment, which is the transmitted carrier. The resolution bandwidth is set 1MHz as
outlined in Part 22.917,Part 24.238(a), Part 27.53(g), Part 27.53(h), Part 27.53(m). The spectrum
was scanned with the mobile station transmitting at carrier frequencies that pertain to low, mid and
high channels of the LTE Band 12.

The procedure of radiated spurious emissions is as follows:
1. EUT was placed on a 1.5 meter high non-conductive stand at a 3 meter test distance from the
    receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT
    for emission measurements. The height of receiving antenna is 1.5m. The test setup refers to
    figure below. Detected emissions were maximized at each frequency by rotating the EUT
    through 360° and adjusting the receiving antenna polarization. The radiated emission
    measurements of all non-harmonic and harmonics of the transmit frequency through the 10th
    harmonic were measured with peak detector.




2.   The EUT is then put into continuously transmitting mode at its maximum power level during
     the test. And the maximum value of the receiver should be recorded as (Pr).
3.   The EUT shall be replaced by a substitution antenna. The test setup refers to figure below.




East China Institute of Telecommunications                                       Page Number: 21 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                             Report Issued Date: Oct.29.2019


                                                                     Report No.I19D00137-SRD06



   In the chamber, an substitution antenna for the frequency band of interest is placed at the
   reference point of the chamber. An RF Signal source for the frequency band of interest is
   connected to the substitution antenna with a cable that has been constructed to not interfere
   with the radiation pattern of the antenna. A power (PMea) is applied to the input of the
   substitution antenna. Adjust the level of the signal generator output until the value of the
   receiver reaches the previously recorded (Pr). The power of signal source (PMea) is recorded.
   The test should be performed by rotating the test item and adjusting the receiving antenna
   polarization.
4. The Path loss (Ppl) between the Signal Source with the Substitution Antenna and the
    Substitution Antenna Gain (Ga) should be recorded after test.
   An amplifier should be connected in for the test.
   The Path loss (Ppl) is the summation of the cable loss and the gain of the amplifier.
   The measurement results are obtained as described below:
   Power (EIRP)=PMea- Ppl + Ga
5. This value is EIRP since the measurement is calibrated using an antenna of known gain (unit:
    dBi) and known input power.
6. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP = EIRP -2.15dB.

A.2.2 Measurement Limit
Part 22.917,Part 24.238(a), Part 27.53(g), Part 27.53(h), Part 27.53(m) all specify that the power
of any emission outside of the authorized operating frequency ranges must be attenuated below
the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The specification that
emissions shall be attenuated below the transmitter power (P) by at least 43 + 10 log (P) dB,
translates in the relevant power range (1 to 0.001 W) to -13 dBm. At 1 W the specified minimum
attenuation becomes 43 dB and relative to a 30 dBm (1 W) carrier becomes a limit of -13 dBm. At
0.001 W (0 dBm) the minimum attenuation is 13 dB, which again yields a limit of -13 dBm. In this
way a translation of the specification from relative to absolute terms is carried out.

A.2.3 Measurement Results
7. Radiated emissions measurements were made only at the upper, middle, and lower carrier
    frequencies of the LTE Bands 12. It was decided that measurements at these three carrier
    frequencies would be sufficient to demonstrate compliance with emissions limits because it
    was seen that all the significant spurs occur well outside the band and no radiation was seen
    from a carrier in one block of the LTE Band 12 into any of the other blocks. The equipment
    must still, however, meet emissions requirements with the carrier at all frequencies over
    which it is capable of operating and it is the manufacturer's responsibility to verify this. The
    evaluated frequency range is from 30MHz to 26GHz.




East China Institute of Telecommunications                                      Page Number: 22 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                            Report Issued Date: Oct.29.2019


                                                                Report No.I19D00137-SRD06



LTE Band 12, 10 MHz, QPSK, Channel 20775
Frequency       PMea          Pcl                   Peak ERP    Limit
                                        Ga (dBd)                            Polarization
  (MHz)         (dBm)       (dBm)                    (dBm)     (dBm)
  1278.6        -48.12        3.9            2.0     -50.02     -13               H

  2123.8        -34.21        4.9            2.8     -36.31     -13               H

  3541.6        -47.02        6.4            4.7     -48.72     -13               V

  4580.4        -51.19        7.4            7.3     -51.29     -13               H

  6034.0        -52.56        8.6            10.4    -50.76     -13               V

  7983.1          -55         9.9            16.6     -48.3     -13               V
LTE Band 12, 10 MHz, QPSK, Channel 21100
Frequency       PMea          Pcl                   Peak ERP    Limit
                                        Ga (dBd)                            Polarization
  (MHz)         (dBm)       (dBm)                    (dBm)     (dBm)
  1673.6        -42.02        4.3            2.9     -43.42     -13               H

  2544.6        -36.07        5.4            3.7     -37.77     -13               V

  3687.7        -49.37        6.6            7.7     -48.27     -13               V

  5468.1        -49.37        8.1            9.5     -47.97     -13               V

  6269.2        -49.08        8.8            10.8    -47.08     -13               H

  6936.9        -50.07        9.3            12.9    -46.47     -13               H
LTE Band 12, 5 MHz, QPSK, Channel 21425
Frequency       PMea          Pcl                   Peak ERP    Limit
                                        Ga (dBd)                            Polarization
  (MHz)         (dBm)       (dBm)                    (dBm)     (dBm)
  2145.4        -35.67        5.0            3.3     -37.37     -13               H

  2960.0        -35.53        5.8            4.7     -36.63     -13               H

  3576.4        -40.95        6.5            4.7     -42.75     -13               V

  4567.6        -51.29        7.4            7.3     -51.39     -13               H

  5964.0        -52.97        8.5            10.4    -51.07     -13               V

  7870.9        -53.11        9.9            15.3    -47.71     -13               V




East China Institute of Telecommunications                                 Page Number: 23 of 24
TEL: +86 21 63843300 FAX: +86 21 63843301                       Report Issued Date: Oct.29.2019


                                                                    Report No.I19D00137-SRD06



ANNEX B. Accreditation Certificate




                                **********END OF REPORT**********