SAR Report Appendix B

FCC ID: U4G-Q10W

RF Exposure Info

Download: PDF
FCCID_4469184

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/3


#01_WLAN2.4GHz_802.11b 1Mbps_Left Cheek_Ch6;Ant 1


Communication System: 802.11b ; Frequency: 2437 MHz;Duty Cycle: 1:1.008
Medium: HSL_2450_190503 Medium parameters used : £= 2437 MHz; 0 = 1.802 S/m; s, = 38.936; p =
1000 kg/m*
Armbient Terperature : 23.5 °C ; Liguid Temperature : 22.5 °C

DASYS5 Configuration:
— Probe: ES3DV3 — SN3270;, ConvF(4.6, 4.6, 4.6) ; Calibrated: 2018/9/24
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE3 Sn577; Calibrated: 2018/9/19
— Phantom: SAM_Left; Type: QDO0OP40CD; Serial: TP:1477
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (921x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.434 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 13.30 V/m;, Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.723 W/kg
SAR(I g) = 0.352 W/kg; SAR(10 g) = 0.171 W/ikg
Maximum value of SAR (measured) = 0.444 W/kg

        dB
         W


        —3.00


        —6.00


        —9.00


        —12.00
                       y


        —15.00
                      E.
                    0 dB = 0.444 W/kg = —3.53 dBW/Akg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/4


#02_WLANSGHz_802.11a 6Mbps_Right Cheek_Ch60;Ant 2


Communication System: 802.11a; Frequency : 5300 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190504 Medium parameters used : £= 5300 MHz; 0 = 4.8 S/m; § = 36.023; p = 1000
kg/m3
Armbient Terperature : 23.4 °C ; Liguid Temperature : 22.4 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(5.12, 5.12, 5.12) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn1399; Calibrated: 2018/11/16
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (111x91x1); Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 1.09 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 11.70 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 1.76 W/kg
SAR(I g) = 0.476 W/ikg; SAR(10 g) = 0.169 W/ikg
Maximum value of SAR (measured) =1.11 W/kg

        dB
         W


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00      [(
                    0 dB = 1.11 W/kg = 0.45 dBW/Akg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/6


#03_WLANSGHz_802.11a 6Mbps_Right Cheek_Ch100;Ant 2


Communication System: 802.11a ; Frequency : 5500 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190506 Medium parameters used: f = 5500 MHz; 0 = 4.982 S/m; s, = 35.679; p = 1000
kg/m3
Armbient Temperature : 23.2 °C ; Liguid Temperature : 22.2 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN7515; ConvF(4.83, 4.83, 4.83) ; Calibrated: 2018/10/3
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (111x91x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.838 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 8.984 V/m;, Power Drift = 0.16 dB
Peak SAR (extrapolated) = 1.37 W/ikg
SAR(I g) = 0.338 W/kg; SAR(10 g) = 0.105 W/kg
Maximum value of SAR (measured) = 0.830 W/kg

        dB
         0


        —5.00


        —10.00


        —15.00


        —20.00


        —25.00      [1
                    0 dB = 0.830 W/kg = —0.81 dBW/Akg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/7


#04_WLANSGHz_802.11a 6Mbps_Right Cheek_Ch157;Ant 2


Communication System: 802.11a ; Frequency: 5785 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190507 Medium parameters used : £= 5785 MHz; 0 = 5.219 S/m; s = 35.868;, p = 1000
kg/m3
Armbient Terperature : 23.1 °C ; Liguid Temperature : 22.1 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.72, 4.72, 4.72) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (121x121x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.854 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 13.41 V/m;, Power Drift =—0.02 dB
Peak SAR (extrapolated) = 1.61 W/ikg
SAR(I g) = 0.350 W/kg; SAR(10 g) = 0.107 W/ikg
Maximum value of SAR (measured) = 0.916 W/kg

        dB
         0


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00      [71.
                    0 dB = 0.916 W/kg = —0.38 dBW/Akg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/3


#05_Bluetooth_1Mbps_Left Cheek_Ch39;Ant 1



Communication System: Bluetooth ; Frequency: 2441 MHz;Duty Cycle: 1:1.311
Medium: HSL_2450_190503 Medium parameters used: f = 2441 MHz; 0 = 1.806 S/m; &, = 38.922; p = 1000
kg/m3
Armbient Terperature : 23.5 °C ; Liguid Temperature : 22.5 °C

DASYS5 Configuration:
— Probe: ES3DV3 — SN3270;, ConvF(4.6, 4.6, 4.6) ; Calibrated: 2018/9/24
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE3 Sn577; Calibrated: 2018/9/19
— Phantom: SAM_Left; Type: QDO0OP40CD; Serial: TP:1477
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (101x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.0226 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 3.079 V/m;, Power Drift = 0.12 dB
Peak SAR (extrapolated) = 0.0360 W/kg
SAR(I g) = 0.018 W/kg; SAR(10 g) = 0.0078 W/ikg
Maximum value of SAR (measured) =0.0231 W/kg

        dB
         W


        —3.00


        —6.00


        —9.00


        —12.00
                       y
                      k.
        —15.00
                    0 dB =0.0231 W/kg =—16.36 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/3


#06_WLAN2.4GHz_802.11b 1Mbps_Back_10mm_Ch11;Ant 2


Communication System: 802.11b; Frequency: 2462 MHz;Duty Cycle: 1:1.008
Medium: HSL_2450_190503 Medium parameters used: f = 2462 MHz; 0 = 1.828 S/m; &, = 38.837; p = 1000
kg/m3
Armbient Terperature : 23.5 °C ; Liguid Temperature : 22.5 °C

DASYS5 Configuration:
— Probe: ES3DV3 — SN3270;, ConvF(4.6, 4.6, 4.6) ; Calibrated: 2018/9/24
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE3 Sn577; Calibrated: 2018/9/19
— Phantom: SAM_Left; Type: QDO0OP40CD; Serial: TP:1477
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (101x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.422 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 13.94 V/m;, Power Drift =—0.07 dB
Peak SAR (extrapolated) = 0.614 W/kg
SAR(I g) =0.321 W/kg; SAR(10 g) = 0.167 W/ikg
Maximum value of SAR (measured) = 0.403 W/kg

        dB
         W


        —3.00


        —6.00


                                                                            ~If
        —12.00


        —15.00        (—
                    0 dB =0.403 W/kg = —3.95 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/4


#07_WLANSGHz_802.11a 6Mbps_Back_10mm_Ch60;Ant 2


Communication System: 802.11a; Frequency : 5300 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190504 Medium parameters used : £= 5300 MHz; 0 = 4.8 S/m; s = 36.023; p = 1000
kg/m3
Armbient Terperature : 23.4 °C ; Liguid Temperature : 22.4 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(5.12, 5.12, 5.12) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn1399; Calibrated: 2018/11/16
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (101x121x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 1.85 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 13.88 V/m;, Power Drift = —0.04 dB
Peak SAR (extrapolated) = 3.38 W/kg
SAR(I g) = 0.923 W/kg; SAR(10 g) = 0.335 W/kg
Maximum value of SAR (measured) =2.10 W/kg

        dB
         o


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00        CC
                    0 dB =2.10 W/kg =3.22 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/6


#08_WLANSGHz_802.11a 6Mbps_Back_10mm_Ch144;Ant 2


Communication System: 802.11a ; Frequency: 5720 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190506 Medium parameters used: f = 5720 MHz; 0 = 5.199 S/m; s = 35.45; p = 1000
kg/m3
Armbient Temperature : 23.2 °C ; Liguid Temperature : 22.2 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.72, 4.72, 4.72) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (111x91x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) =2.22 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 16.47 V/m;, Power Drift =—0.13 dB
Peak SAR (extrapolated) = 3.55 W/kg
SAR(I g) = 0.898 W/kg; SAR(10 g) = 0.333 W/kg
Maximum value of SAR (measured) =2.07 W/kg

        dB
         0


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00        _
                    0 dB =2.22 W/kg = 3.46 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/6


#09_WLANSGHz_802.11a 6Mbps_Back_10mm_Ch157;Ant 2


Communication System: 802.11a ; Frequency: 5785 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190506 Medium parameters used : £= 5785 MHz; 0 = 5.265 S/m; s = 35.385;, p = 1000
kg/m3
Armbient Temperature : 23.2 °C ; Liguid Temperature : 22.2 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.72, 4.72, 4.72) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (111x91x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) =2.07 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 17.30 V/m;, Power Drift =—0.14 dB
Peak SAR (extrapolated) = 3.39 W/kg
SAR(I g) = 0.857 W/kg; SAR(10 g) = 0.330 W/kg
Maximum value of SAR (measured) = 1.94 W/kg

        dB
         o


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00        (—
                    0 dB =2.07 W/kg =3.16 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/3


#10_Bluetooth_1Mbps_Back_10mm_Ch39;Ant 1


Communication System: Bluetooth ; Frequency: 2441 MHz;Duty Cycle: 1:1.311
Medium: HSL_2450_190503 Medium parameters used: f = 2441 MHz; σ = 1.806 S/m; εr = 38.922; ρ = 1000
kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.5 ℃

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(4.6, 4.6, 4.6) ; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1477
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (91x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.0168 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 2.944 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.0250 W/kg
SAR(1 g) = 0.013 W/kg; SAR(10 g) = 0.00605 W/kg
Maximum value of SAR (measured) = 0.0157 W/kg




                    0 dB = 0.0157 W/kg = -18.04 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/3


#11_WLAN2.4GHz_802.11b 1Mbps_Left Side_Omm_Ch11;Ant 2


Communication System: 802.11b; Frequency: 2462 MHz;Duty Cycle: 1:1.008
Medium: HSL_2450_190503 Medium parameters used: f = 2462 MHz; 0 = 1.828 S/m; &, = 38.837; p = 1000
kg/m3
Armbient Terperature : 23.5 °C ; Liguid Temperature : 22.5 °C

DASYS5 Configuration:
— Probe: ES3DV3 — SN3270;, ConvF(4.6, 4.6, 4.6) ; Calibrated: 2018/9/24
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE3 Sn577; Calibrated: 2018/9/19
— Phantom: SAM_Left; Type: QDO0OP40CD; Serial: TP:1477
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (61x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) =2.97 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 30.78 V/m;, Power Drift = 0.05 dB
Peak SAR (extrapolated) =7.18 W/kg
SAR(I g) =2.32 W/kg; SAR(10 g) = 0.826 W/ikg
Maximum value of SAR (measured) =3.35 W/kg

        dB
         W


        —3.00


        —6.00


        —9.00


        —12.00


        —15.00        C
                    0 dB =3.35 W/kg = 5.25 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/4


#12_WLANSGHz_802.11a 6Mbps_Back_Omm_Ch60;Ant 2


Communication System: 802.11a; Frequency : 5300 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190504 Medium parameters used : £= 5300 MHz; 0 = 4.8 S/m; § = 36.023; p = 1000
kg/m3
Armbient Terperature : 23.4 °C ; Liguid Temperature : 22.4 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(5.12, 5.12, 5.12) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn1399; Calibrated: 2018/11/16
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (101x121x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 12.0 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 16.73 V/m;, Power Drift = —0.06 dB
Peak SAR (extrapolated) = 57.1 W/kg
SAR(I g) =9.1 W/kg; SAR(10 g) = 1.75 W/kg
Maximum value of SAR (measured) = 25.5 W/kg

        dB
         W


        —8.00


        —16.00


        —24.00


        —32.00


        —40.00        CC‘
                    0 dB =25.5 W/kg = 14.07 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/7


#13_WLANSGHz_802.11a 6Mbps_Back_Omm_Ch100;Ant 1


Communication System: 802.11a; Frequency : 5500 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190507 Medium parameters used: f = 5500 MHz; 0 = 4.908 S/m; & = 36.192; p = 1000
kg/m3
Armbient Terperature : 23.1 °C ; Liguid Temperature : 22.1 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.47, 4.47, 4.47) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (111x91x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 19.0 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 11.07 V/m; Power Drift = —0.18 dB
Peak SAR (extrapolated) = 44.8 W/kg
SAR(I g) =6.13 W/kg; SAR(10 g) = 1.14 W/ikg
Maximum value of SAR (measured) = 18.0 W/kg

        dB
         0


        —5.00


        —10.00


        —15.00


        —20.00


        —25.00        C
                    0 dB = 18.0 W/kg = 12.55 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/7


#14_WLANSGHz_802.11a 6Mbps_Back_Omm_Ch149;Ant 2


Communication System: 802.11a ; Frequency: 5745 MHz;Duty Cycle: 1:1.06
Medium: HSL_5G_190507 Medium parameters used : £= 5745 MHz; 0 = 5.174 S/m; § = 35.868;, p = 1000
kg/m3
Armbient Terperature : 23.1 °C ; Liguid Temperature : 22.1 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.72, 4.72, 4.72) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Right;, Type: SAM; Serial: TP:1479
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (111x91x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 11.4 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 10.92 V/m;, Power Drift = —0.04 dB
Peak SAR (extrapolated) = 32.0 W/kg
SAR(I g) =4.7 W/kg; SAR(10 g) = 0.948 W/kg
Maximum value of SAR (measured) = 14.3 W/kg

        dB
         0


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00        (_—
                    0 dB = 14.3 W/kg = 11.55 dBW/Akg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/3


#15_Bluetooth_1Mbps_Right Side_Omm__Ch39;Ant 1



Communication System: Bluetooth ; Frequency: 2441 MHz;Duty Cycle: 1:1.311
Medium: HSL_2450_190503 Medium parameters used: f = 2441 MHz; 0 = 1.806 S/m; &, = 38.922; p = 1000
kg/m3
Armbient Terperature : 23.5 °C ; Liguid Temperature : 22.5 °C

DASYS5 Configuration:
— Probe: ES3DV3 — SN3270;, ConvF(4.6, 4.6, 4.6) ; Calibrated: 2018/9/24
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE3 Sn577; Calibrated: 2018/9/19
— Phantom: SAM_Left; Type: QDO0OP40CD; Serial: TP:1477
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)



Area Scan (51x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) =0.101 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value =6.133 V/m;, Power Drift =0.12 dB
Peak SAR (extrapolated) = 0.190 W/kg
SAR(I g) = 0.071 W/kg; SAR(10 g) = 0.029 W/kg
Maximum value of SAR (measured) = 0.102 W/kg

        dB
         W


        —3.00


        —6.00


        —9.00


        —12.00


        —15.00        (—
                    0 dB = 0.102 W/kg = —9.91 dBW/Akg