Test report RFID

FCC ID: U4GJNG3SD

Test Report

Download: PDF
FCCID_3230204

                                           TEST REPORT
                                          No.: 2-20842790-15-11a

                                                       According to:
                                                     FCC Regulations
                                                            Part 15.225
                                                            Part 15.207
                                                            Part 15.209
                                                       IC Regulations
                                                        RSS-210, Issue 9
                                                        RSS-Gen Issue 4


                                                              for

                                      Datalogic ADC S.r.l.
                                 JOYA TOUCH 3-SLOT CRADLE
                                                 FCC-ID: U4GJNG3SD
                                                  IC: 3862E-JNG3SD
                                          PMN: JOYA TOUCH 3-SLOT CRADLE
                                                    HVIN: 3SD WPT




                                           Laboratory Accreditation and Listings




                                                                                                  Voluntary Controls for
                                                                            Industry Canada    Electromagnetic Emissions

                                                                           Reg. No.: 3462D-2           Reg. No.:
                                                     MRA US-EU 0003                                 R-2666 C-2914,
                                                                           Reg. No.: 3462D-3
                                                                                                    T-1967, G-301




                                     accredited according to DIN EN ISO/IEC 17025
                                                   CETECOM GmbH
                              Laboratory Radio Communications & Electromagnetic Compatibility
                                          Im Teelbruch 116 • 45219 Essen • Germany
                                 Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                               Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                   E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                    Page 1 of 25
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without
the written approval of the testing laboratory                                  © Copyright: All rights reserved by CETECOM


Test Report 2-20842790-15-11a, Page 2 of 25



TABLE OF CONTENTS
1. SUMMARY OF TEST RESULTS ..................................................................................................................... 3
  1.1. Tests overview according CFR47, Part 15, Subpart C .................................................................................... 3
2. ADMINISTRATIVE DATA .............................................................................................................................. 4
  2.1. Identification of the testing laboratory ............................................................................................................ 4
  2.2. Test location ................................................................................................................................................... 4
  2.3. Organizational items ....................................................................................................................................... 4
  2.4. Applicant’s details .......................................................................................................................................... 4
  2.5. Manufacturer’s details .................................................................................................................................... 4
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................ 5
  3.1. Technical data of main EUT declared by applicant ........................................................................................ 5
  3.2. EUT: Type, S/N etc. and short descriptions used in this test report ............................................................... 5
  3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ................................................................. 6
  3.4. EUT set-ups .................................................................................................................................................... 6
  3.5. EUT operating modes ..................................................................................................................................... 6
4. DESCRIPTION OF TEST SYSTEM SET-UP’S ............................................................................................. 7
  4.1. Test system set-up for AC power-line conducted emission measurements .................................................... 7
  4.2. Test system set-up for conducted measurements on antenna port ................................................................... 8
  4.3. Test system set-up for radiated magnetic field measurements below 30 MHz ................................................ 9
  4.4. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz .............................................. 10
5. MEASUREMENTS ............................................................................................................................................ 11
  5.1. General Limit - Conducted emissions on AC-Power lines ............................................................................. 11
  5.2. Radiated field strength emission mask at 13.110-14.010MHz ....................................................................... 12
  5.3. General Limit - Radiated field strength emissions below 30 MHz ................................................................. 13
  5.4. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz ............................................................. 15
  5.5. Frequency error (tolerance) ............................................................................................................................ 17
  5.6. Measurement uncertainties ............................................................................................................................. 20
6. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ........................ 21
7. INSTRUMENTS AND ANCILLARY ............................................................................................................... 22
  7.1. Used equipment “CTC” .................................................................................................................................. 22
8. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................ 25

 Table of annex                       The listed attachments are an integral part of this report                                                     Total pages
Annex 1: Test result diagrams (separate document) TR2-20842790-15-11a-A1                                                                                            32
Annex 2: External photographs of EUT (separate document) TR2-20842790-15-11a-A2                                                                                       5
Annex 3: Internal photographs of EUT (separate document) TR2-20842790-15-11a-A3                                                                                     12
Annex 4: Test set-up photographs (separate document) TR2-20842790-15-11a-A4                                                                                           9
Operational Description_JOYA TOUCH 3-SLOT CRADLE_20160530_rev03 (supplied by applicant)                                                                               7
JOYANG_TEST-TOOLS_QUICK_START_INSTRUCTIONS_REV20160530 (supplied by applicant)                                                                                      41
Operational Description_JOYA TOUCH_20160530_rev05 (supplied by applicant)                                                                                           10




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 3 of 25




1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does
not assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a radio transmitting device with a
integrated RFID Transmitter at nominal 13.56MHz.


1.1. Tests overview according CFR47, Part 15, Subpart C

                                                               REFERENCES & LIMITS                                            EUT
                                                                                                             EUT             opera-
TEST CASES                    PORT                       FCC Standard                                                                              Result
                                                                                 TEST LIMIT                 set-up            ting
                                                         RSS Standard                                                        mode
      FIELD                                                  §2.1046          FCC Part 15.225 limits
    STRENGTH                                                 §15.225
 (radiated in 30m                                             (a)(b)
                              Cabinet                                                                            1               1                    Pass
   measurement                                                (c)(d)
    distance) &
EMISSION MASK                                            RSS-210 , Issue9         IC: Annex B.6

                                                              §2.202                99% Power
                             Antenna                                                                                                               For
99% OCCUPIED                                                 §2.1049
                             coupling                                                                            2               1             information
 BANDWIDTH                     (radiated)                                                                                                          only
                                                         RSS-Gen Issue 4          IC: Chapter 6.6

                              Cabinet                       §15.209(a)       FCC:2400/F(kHz) µV/m
   SPURIOUS                       +                                           24000/F(kHz) µV/m
   EMISSIONS                  Intercon                                             30 µV/m                       1               1                    Pass
       (radiated)              necting
                               cables                    RSS-Gen Issue 4          IC: Chapter 8.9
                               (radiated)



                                                             §2.1055              FCC: ±100ppm
  FREQUENCY                  Antenna                        §15.225(e)
                             coupling                                                                            2               2                    Pass
   STABILITY                   (radiated)
                                                         RSS-210 , Issue 9   IC: ±0.01% (±100 ppm).


 AC-Power Lines
                                AC-                          §15.207            FCC §15.207 limits
                               Power                                                                             3               1                    Pass
     Conducted
                                lines                    RSS-Gen Issue 4     IC: Table 4, Chapter 7.2.4
     Emissions




                            Digitally signed by
                            christian.                                                                                            Digital unterschrieben von
                            lorenz@cetecom.com                                                                                    Ajit Phadtare
                                                                                                                                  DN: cn=Ajit Phadtare,
                            DN: cn=christian.                                                                                     o=CETECOM GmbH, ou=RC-
                            lorenz@cetecom.com                                                                                    EMC,
                                                                                                                                  email=ajit.phadtare@ceteco
                            Date: 2016.12.05 10:33:13                                                                             m.com, c=DE
                                                                                                                                  Datum: 2016.12.05 10:27:35
                            +01'00'                                                                                               +01'00'
......................................................                                                 ....................................................
Dipl.-Ing. Ch. Lorenz                                                                                                       MSc. Ajit Phadtare
Responsible for test section                                                                                     Responsible for test report




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 4 of 25




2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report :                                         MSc. Ajit Phadtare
Project leader:                                                       Dipl.-Ing. V. Krueger
Receipt of EUT:                                                       2016-02-29
Date(s) of test:                                                      2016-04-21 to 2016-06-28
Date of report:                                                       2016-12-05
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     Datalogic ADC S.r.l.
Address:                                                              Via S. Vitalino, 13
                                                                      40012, Lippo di Calderara di Reno (BO)

                                                                      ITALY
Contact person:                                                       Mr.Eucarpio Guarisco



2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 5 of 25




3. Equipment under test (EUT)
3.1. Technical data of main EUT declared by applicant
Main function                         Wireless charger for JOYA TOCUH Terminals
Type                                  JOYA TOUCH 3-SLOT CRADLE
Frequency range and channels
                                      13.553 -13.567 MHz
(US/Canada -bands)
Type of modulation (packet types)     ASK (Amplitude Shift Keying)
Occupied bandwidth                    38.94 kHz
Number of channels
                                      1 nominal channel at 13.56MHz
(USA/Canada -bands)
                                       Integrated
Antenna Type                           External, no RF- connector
                                       External, separate RF-connector
Antenna Gain                          No information from applicant
MAX Field strength (radiated):        26.73 dBμV/m Peak@30m distance
Installed options                      battery charging option (WPC) (not tested within this test report)

Power supply                           12 V DC using AC/DC adapter: 120V/60 Hz

Special EMI components                --
EUT sample type                        Production       Pre-Production   Engineering
Firmware                                                 for normal use  Special version for test execution
FCC label attached                     yes              no


3.2. EUT: Type, S/N etc. and short descriptions used in this test report
Short
                                                                   S/N              HW                 SW
descrip-              EUT                     Type
                                                                  serial       hardware status    software status
tion*)
                                                                 number
                                                                                 Beta 2 HW
                                                                                                    Firmware
               JOYA TOUCH                                                         Version
EUT A                                         N/A              Z15P00993                            Version:
             3- SLOT CRADLE
                                                                              P/N:91ACC0043         99.99.99
*) EUT short description is used to simplify the identification of the EUT in this test report.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 6 of 25



3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

   AE
                                                                S/N                 HW                   SW
  short     Auxiliary Equipment           Type
                                                           serial number       hardware status      software status
descrip-
 tion *)
                                                                                                        SW
                                                                                  Beta HW
                                    P00AN04HL0H                                                    Version:WEC7
  AE 1         JOYA TOUCH                                   Z16P00044             Version
                                      T0W7-GR0                                                       Firmware
                                                                               P/N:911350015
                                                                                                    Version: 2.16
                                                                                                        SW
                                                                                  Beta HW
                                    P00AN04HL0G                                                    Version:WEC7
  AE 2         JOYA TOUCH                                   Z16P00014              Version
                                     T0W7-GRR                                                        Firmware
                                                                               P/N:9113500013
                                                                                                    Version: 2.16
              AC/DC Adapter
                                                                               120 V AC 60 Hz
  AE 3         EDACPOWER             EA10681U-120        331210680014C3                                    --
                                                                                to 12VDC 6 A
                  ELEC
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.4. EUT set-ups

EUT set-up
                        Combination of EUT and AE                                    Remarks
  no.*)

   set. 1                   EUT A + AE 1+AE 3                        Radiated Measurements table top set up

   set. 2                   EUT A + AE 2+AE 3                  Conducted Measurements Antenna coupling set up

   set. 3                   EUT A + AE 1+AE 3                     AC-Power Lines Conducted Emissions set up
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.


3.5. EUT operating modes

   EUT
                 Description of
 operating                                                       Additional information
                operating modes
mode no.*)
                                    Continuous NFC (13.56 MHz) Tx mode activated between EUT A & AE 1
                                    using Cradle Test application.
                      TX-Mode
    op. 1                               - modulated signal with maximum output power
                      Modulated
                                        - Duty-Cycle greater than 98%.
                                        - AE1 used for exchanging the RF information.
                                    Continuous NFC (13.56 MHz) Tx mode activated in only EUT A
                   TX-Mode              - unmodulated signal with maximum output power
    op. 2
                  Unmodulated           - Duty-Cycle greater than 98%.
                                        - AE1 used only to maintain unmodulated NFC signal
*) EUT operating mode no. is used to simplify the test report.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 7 of 25




4. Description of test system set-up’s
4.1. Test system set-up for AC power-line conducted emission measurements


Specification:             ANSI C63.4-2009 chapter 7, ANSI C63.10-2013 chapter 6.2

General Description:       The radio frequency voltage conducted back into the AC power line in the
                           frequency range 150 kHz to 30 MHz has to be investigated. Compliance should be
                           tested by measuring the radio frequency voltage between each power line and
                           ground at the power terminals in the stated frequency range.
                           A 50 Ohm / 50 µH line impedance stabilization network (LISN) is used coupling
                           the interface to the measurement equipment. The EUT power input leads are
                           connected through the LISN to the AC-power source. The LISN enclosure is
                           electrically connected to the ground plane. The measuring instrument is connected
                           to the coaxial output of the LISN.
                           Tabletop devices were set-up on a 80 cm height above reference ground plane,
                           floor standing equipment 10 cm raised above ground plane. Measurements have
                           been performed on each phase line and neutral line of the devices AC-power lines.
                           The EUT was power supplied with 110 V/60 Hz. The EUT was tested in the
                           defined operating mode and installed (connected) to accessory equipment
                           according the general description of use given by the applicant.

Schematic:




                           Only schematic view, we refer to figure 6, 7 and 8 of ANSI C63.4-2009 for more details.



Testing method:            Exploratory, preliminary measure-                  Final testing for power phases and
                           ments as a first step, determines the              critical frequencies (Margin to AV- or
                           worst-case phase line (neutral or phase)           QP limit lower than 3 dB) as a second
                           as well as the most critical operating             step includes measurements with
                           mode of the equipment. A complete                  receivers detector set to Quasi-Peak and
                           frequency-sweep with PK-Detector is                Average.
                           performed on each current-carrying
                           conductor.

Formula:                   VC= VR + CL (1)                          VC = measured Voltage –corrected value
                           M= LT-VC (2)                             VR = Receiver reading
                                                                    CL = Cable loss
                                                                    M = Margin
                                                                    LT = Limit
                           Values are in dB, positive margin means value is below limit.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 8 of 25


4.2. Test system set-up for conducted measurements on antenna port


Specification:             ANSI 63.10:2013

Schematic:                 In case an external connector is not available, the coupling unit consists of a
                           near-field antenna which is directly connected to the spectrum analyzer.




Testing method:            ANSI 63.10:2013, Chapter 6.7




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 9 of 25


4.3. Test system set-up for radiated magnetic field measurements below 30 MHz


Specification:             ANSI C63.4-2009 chapter 8.2.1, ANSI C63.10-2013 chapter 6.4

General Description:       Evaluating the radiated field emissions are done first by an exploratory emission
                           measurement and a final measurement for most critical frequencies determined.
                           The loop antenna was placed at 1 m height above ground plane and 3 m
                           measurement distance from set-up for investigations. Because of reduced
                           measurement distance, correction data were applied, as stated in chapter “General
                           Limit - Radiated field strength emissions below 30 MHz“. The tests are
                           performed in the semi anechoic room recognized by the regulatory commission.

Schematic:




Testing method:            Exploratory, preliminary measurement                Final measurement on critical frequencies
                           The EUT and it’s associated accessories are         Based on the exploratory measurements, the most
                           placed on a non-conductive position manipulator     critical frequencies are re-measured by main-
                           (tipping device) of 0.8 m height which is placed    taining the EUT’s worst-case operation mode,
                           on the turntable. By rotating the turntable (step   cable position, etc.
                           90°, range 0°to 360°) and the EUT itself either
                           on 3-orthogonal axis (portable equipment) or 2-     First a frequency zoom around the critical
                           orthogonal axis (defined operational position of    frequency is done to locate the frequency more
                           EUT), the emission spectrum was recorded. The       precisely. After this step, for all identified critical
                           loop antenna was moved at least to                  frequencies, the maximum peak was determined.
                           2-perpendicular axes (antenna vector in direction
                           of EUT and parallel to EUT) in order to             Following parameters were varied: the turntable
                           maximize the emissions. The results are             angle continuously in the range 0 to 360 degree,
                           documented in a diagram. Critical frequencies       the EUT itself either over 3-orthogonal axis (not
                           (low margin to limit) are saved within a data       defined usage position) or 2-orthogonal axis
                           reduction table for further investigations. If      (defined usage position).
                           various operating modes are supported, further
                           investigations are made to find the worst-case.     On the determined worst-case position, a final
                           Also the interconnection cables and equipment       measurement with necessary bandwidth and
                           position were varied in order to maximize the       detector according standard has been carried out.
                           emissions.

Formula:                   EC = ER + AF + CL + DF - GA               AF =Antenna factor
                                                                     CL = Cable loss
                           M = LT-EC                                 DF= Distance correction factor
                                                                     EC = Electrical field – corrected value
                                                                     ER = Receiver reading
                                                                     GA= Gain of pre-amplifier (if used)
                                                                     LT = Limit
                                                                     M = Margin
                           All units are dB-units, positive margin means value is below limit.

Distance correction:       Reference for applied correction (extrapolating) factors:
                           IEEC Transaction EMC, Vol. 47, No. 3 , Aug. 2005, Journal Paper
                           “Extrapolating Near-field emissions of low frequency loop transmitters”.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 10 of 25


4.4. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz


Specification:             ANSI C63.4-2009 chapter 8, ANSI C63.10-2013 chapter 6.5

General Description:       Evaluating the field emissions have to be done first by an exploratory emissions
                           measurement and a final measurement for most critical frequencies. The tests are
                           performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                           regulatory commissions.

Schematic:




Testing method:            Exploratory, preliminary measurements                Final measurement on critical frequencies
                           The EUT and its associated accessories are           Based on the exploratory measurements, the most
                           placed on a non-conductive position manipulator      critical frequencies are re-measured by main-
                           (tipping device) of 0.8 m height which is placed     taining the EUT’s worst-case operation mode,
                           on the turntable. By rotating the turntable (range   cable position, etc.
                           0° to 360°, step 90°) and the EUT itself either on
                           3-orthogonal axis (portable equipment) or 2-         First a frequency zoom around the critical
                           orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                           EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                           characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                           receiver, broadband antenna and software.
                                                                                Following parameters were varied: the turntable
                           Measurement antenna: horizontal and vertical,        angle continuously in the range 0 to 360 degree,
                           heights: 1,0 m and 1,82 m as worst-case              the EUT itself either over 3-orthogonal axis (not
                           determined by an exploratory emission                defined usage position) or 2-orthogonal axis
                           measurements. The results are documented in a        (defined usage position). The measurement
                           diagram. Critical frequencies (low margin to         antenna height between 1 m and 4 m.
                           limit) are saved within a table for further
                           investigations. If various operating modes are       On the determined worst-case position, a final
                           supported, further investigations are made to find   measurement with necessary bandwidth and
                           the worst-case of them. Also the interconnection     detector according standard has been carried out.
                           cables and equipment position were varied in
                           order to maximize the emissions.

Formula:                   EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                     CL = Cable loss
                           M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                     EC = Electrical field – corrected value
                                                                     ER = Receiver reading
                                                                     GA = Gain of pre-amplifier (if used)
                                                                     LT = Limit
                                                                     M = Margin
                           All units are dB-units, positive margin means value is below limit.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 11 of 25




5. Measurements
5.1. General Limit - Conducted emissions on AC-Power lines
5.1.1. Test location and equipment
test location    CETECOM Essen (Chapter 2.2.1)     Please see Chapter 2.2.2          Please see Chapter 2.2.3
 test site       333 EMI field  348 EMI cond.
 receiver        001 ESS         377 ESCS 30      489 ESU 40        620 ESU 26
 LISN            005 ESH2-Z5  007 ESH3-Z6         300 ESH3-Z5 & 50 used for AE     no LISN for AE
 signaling       392 MT8820A  436 CMU             547 CMU           594 CMW
 line voltage    12 VDC (for EUT A supplied from AE3)                 060 120 V 60 Hz via PAS 5000 (for AE3)

5.1.2. Requirements
          FCC                  Part 15, Subpart B, §15.207
           IC                  RSS-Gen Issue 4, Chapter 8.8, Table 3
          ANSI                 C63.10-2013
              Frequency
    Limit     [MHz]                         QUASI-Peak [dBµV]                                    AVERAGE [dBµV]

              0.15 – 0.5                        66 to 56*                                             56 to 46*
  Class B       0.5 – 5                            56                                                    46
                5 – 30                             60                                                    50
 Remark: * decreases with the logarithm of the frequency

5.1.3. Test condition and test set-up
Signal link to test system (if used):         air link  cable connection  none
EUT-grounding                                 none  with power supply  additional connection
Equipment set up                              table top                        floor standing
                                             (40 cm distance to reference       EUT stands isolated on reference ground plane (floor)
                                             ground plane (wall)
Climatic conditions                          Temperature: (22±3°C)             Rel. humidity: (40±20)%
                                              9 – 150 kHz,            RBW = 200 Hz, Step = 61 Hz
                   Scan data                  150 kHz – 30 MHz        RBW = 9 kHz,       Step = 4 kHz
 EMI-Receiver or                              other:
 Analyzer settings Scan-Mode                 6 dB EMI-Receiver Mode
                   Pre-measurement           Peak detector, Repetitive-Scan, max-hold, sweep-time 50 µs per frequency point
                   Final measurement         Average & Quasi-peak detector at critical frequencies
General measurement procedures               Please see chapter “Test system set-up for AC power line conducted emissions measurements”

5.1.4. Measurement results
The results are presented below in summary form only. For more information please see the diagrams
                             Set-up no.:3                                                  EUT OP-mode no.: 1
 Diagram-                                    Power                                                                        Result
                    Used Detector                           Additional (scan-) information           Remarks
   No.                                        line
                                                  Measurement performed with NFC
                 Peak (pre-scan)
                                                  antenna in normal operating mode. For Remark 1)
   1.01          CAV (final)           L1/ N                                                         Inconclusive
                                                  compliance further investigations are Remark 2)
                 QP   (final)
                                                  necessary.
            Peak (pre-scan)                      Measurement performed without NFC
  1.01b     CAV (final)                L1/ N     antenna & NFC output port             Remark 1)         Pass
            QP      (final)                      terminated with 50 Ohm impedance.
Remark: 1.) For further details please refer diagrams in separate annex A1
         2.) Reference Measurement diagram No .1.01 is valid only in combination with Measurement diagram No .1.01b




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 12 of 25




5.2. Radiated field strength emission mask at 13.110-14.010MHz
5.2.1.TEST LOCATION AND EQUIPMENT (for reference numbers please see chapter 'List of test
equipment')
 test location       CETECOM Essen (Chapter. 2.2.1)     Please see Chapter. 2.2.2           Please see Chapter. 2.2.3
 test site           441 EMI SAR  487 SAR NSA  337 OATS                  347 Radio.lab.                    
 receiver            377 ESCS30      001 ESS                                                               
 spectr. analys.     120 FSEM        264 FSEK                                                              
 antenna             048 EMCO3143  133 EMCO3115  302 BBHA9170  289 CBL 6141               030 HFH-Z2 
 power supply        087 EA 3013 S  457 EA 3013A  459 EA 2032-50  268 EA- 3050            494 AG6632A  498 NGPE 40
 otherwise           400 FTC40x15E  401 FTC40x15E  110 USB LWL  482 Filter Matrix  477 GPS                 
line voltage         12 VDC (for EUT A supplied from AE3)                   060 120 V 60 Hz via PAS 5000 (for AE3)

5.2.2. STANDARDS AND LIMITS: CFR 47, §15.225(a)(b)(c)(d) & RSS-210, Issue 9 Annex B.6
                                           Field strength                   Measurement
      Frequency
                                                                             distance                          Remarks
        [MHz]                     [μV/m]                 [dBuV/m]            [meters]
    13.553 -13.567
                                  15.848                    84.00                30
   (allocated band)
    13.410-13.710                  334                      50.47                30            Correction factor used due to measurement
    13.110-14.010                  106                      40.50                30                          distance of 3m
     Outside band
                                   30                       29.5                 30
    13.110-14.010

5.2.3. TEST CONDITION AND MEASUREMENT TEST SET-UP
link to test system (if used):                 air link  cable connection          
EUT-grounding                                  none         with power supply  additional connection
Equipment set up                               table top                             floor standing
Climatic conditions                           Temperature: (22±3°C)                  Rel. humidity: (40±20)%
EMI-Receiver (Analyzer) Settings              Span/Range:     9kHz to 150kHz; 150 kHz to 30 MHz
                                              RBW/VBW:        200Hz/auto; 10 kHz/ auto (ANSI63.10/CISPR#16)
                                              Detector/ Mode: PEAK, TRACE max-hold mode, repetitive scan for exploratory measurements
                                                              Quasi-Peak, for final measurement on critical frequencies (f<1GHz)

5.2.4. GENERAL MEASUREMENT PROCEDURES:

The measurement test set-up and test procedure are in accordance with the provisions described in ANSI 63.10:
2013
The Equipment under Test (EUT) was set-up to defined operating mode and installed (connected) to accessory
equipment according the general description of use given by the applicant.

The measurement loop antenna was situated in 3m distance to the EUT. Between EUT and measurement antenna
absorbers are covering the GND-Plane. Radiated magnetic emission measurements were made with the antenna
situated in 1 meter height. The loop antenna was moved at least to 2-perpendicular axes (antenna vector in
direction of EUT and parallel to EUT) in order to maximize the emissions, the EUT itself either over 3-
orthogonal axes (no defined usage position) or 2-orthogonal axis (defined usage position).

According the standard the compliance should be checked in 30m measurement distance. Therefore an additional
extrapolation factor was used in order to normalize the measurement data. The frequency dependent
extrapolation factor used for this reduced measurement distance, can be found in the chapter 5.3.4.1

5.2.5. MEASUREMENT RESULTS: CARRIER FIELD STRENGTH (EMISSION MASK)

                    Carrier                         Set-      OP-
Diagram                            Frequency                                                                   Used detector
                    Channel                          up       mode                    Remark                                      Result
  No.                                range
                                                    no.        no.
                   Range   No.                                                                                PK AV        QP

   2.05       nominal         1   12 - 15 MHz        1             1   Carrier field strength:26.73 dBuV/m                      Pass
Remark: 1.) For further details please refer diagrams in separate annex A1


5.2.6. VERDICT: Pass



TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 13 of 25


5.3. General Limit - Radiated field strength emissions below 30 MHz
5.3.1. Test location and equipment
test location       CETECOM Essen (Chapter. 2.2.1)     Please see Chapter. 2.2.2          Please see Chapter. 2.2.3
test site           441 EMI SAR  487 SAR NSA  347 Radio.lab.                                               
receiver            377 ESCS30      001 ESS                                                               
spectr. analys.     584 FSU         120 FSEM          264 FSEK                                            
antenna             574 BTA-L       133 EMCO3115  302 BBHA9170  289 CBL 6141            030 HFH-Z2  477 GPS
signaling           392 MT8820A  371 CBT32            547 CMU           594 CMW
otherwise           400 FTC40x15E  401 FTC40x15E  110 USB LWL  482 Filter Matrix  378 RadiSense
DC power            087 EA 3013S  457 EA 3013A  459 EA 2032-50  268 EA- 3050            494 AG6632A  498 NGPE 40
line voltage        12 VDC (for EUT A supplied from AE3)                  060 120 V 60 Hz via PAS 5000 (for AE3)



5.3.2. Requirements
       FCC             Part 15, Subpart C, §15.205 & §15.209
        IC             RSS-Gen., Issue 4: Chapter 8.9, Table 5
       ANSI            C63.10-2013
    Frequency                     Field strength limit                Distance
                                                                                                          Remarks
      [MHz]                [μV/m]               [dBμV/m]                [m]
  0.009 – 0.490            2400/f (kHz)   67.6 – 20Log(f) (kHz)         300       Correction factor used due to measurement distance of 3 m
  0.490 – 1.705        24000/f (kHz)      87.6 – 20Log(f) (kHz)         30        Correction factor used due to measurement distance of 3 m
    1.705 – 30                 30                  29.5                 30        Correction factor used due to measurement distance of 3 m



5.3.3. Test condition and test set-up
Signal link to test system (if used):         air link      cable connection        none
EUT-grounding                                 none          with power supply  additional connection
Equipment set up                              table top                              floor standing
Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
                                              9 – 150 kHz             RBW/VBW = 200 Hz           Scan step = 80 Hz
                      Scan data               150 kHz – 30 MHz RBW/VBW = 9 kHz                   Scan step = 4 kHz
                                              other:
 EMI-Receiver or Scan-Mode                    6 dB EMI-Receiver Mode  3dB Spectrum analyser Mode
 Analyzer Settings Detector                  Peak (pre-measurement) and Quasi-PK/Average (final if applicable)
                   Mode:                     Repetitive-Scan, max-hold
                   Sweep-Time                Coupled – calibrated display if continuous signal otherwise adapted to EUT’s individual
                                             transmission duty-cycle
General measurement procedures               Please see chapter “Test system set-up radiated magnetic field measurements below 30 MHz”



5.3.4. Measurement Results

The results are presented below in summary form only. The EUT is put on operation on nominal channel.
Table of measurement results:
                  Carrier                             Set-       OP-
Diagram                                                                                                          Used detector
                  Channel        Frequency range       up        mode                 Remark                                        Result
  No.
                                                      no.         no.
                   Range                                                                                        PK AV        QP

                                                                             13.56 MHz NFC Carrier on
   2.06           Nominal       9 kHz-30 MHz              1       1                                                               Pass
                                                                          diagram: Not relevant for verdict
Remark: 1.) For further details please refer diagrams in separate annex A1




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 14 of 25


5.3.4.1. Correction factors due to reduced meas. distance (f< 30 MHz)

The used correction factors when the measurement distance is reduced compared to regulatory measurement
distance, are calculated according Extrapolation formulas valid for EUT’s with maximum dimension of
0.625xLambda. Formula 2+3+4 as presented in ANSI C63.10, Chapter 6.4.4 are used for the calculations of
proper extrapolation factors.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 15 of 25


5.4. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.4.1. Test location and equipment
test location       CETECOM Essen (Chapter. 2.2.1)      Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
test site           441 EMI SAR  487 SAR NSA
receiver            377 ESCS30      001 ESS            489 ESU 40        620 ESU 26
spectr. analys.     584 FSU         120 FSEM           264 FSEK
antenna             574 BTA-L       133 EMCO3115  302 BBHA9170  289 CBL 6141                    030 HFH-Z2          477 GPS
signaling           392 MT8820A  371 CBT32             547 CMU           594 CMW
otherwise           400 FTC40x15E  401 FTC40x15E  110 USB LWL  482 Filter Matrix
DC power            087 EA 3013S  457 EA 3013A  459 EA 2032-50  268 EA- 3050                    494 AG6632A  498 NGPE
line voltage        12 VDC (for EUT A supplied from AE3)                  060 120 V 60 Hz        via PAS 5000 (for AE3)



5.4.2. Requirements/Limits
                                             Part 15 Subpart B, §15.109, class B
                    FCC
                                             Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                             RSS-Gen., Issue 4, Chapter 8.9, Table 4
                        IC
                                             C63.4-2009
                    ANSI
                                             C63.10-2013
                                                                     Radiated emissions limits, 3 meters
                     Frequency [MHz]
                                                       QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                              30 - 88                        100                                         40.0
   Limit
                              88 - 216                       150                                         43.5
                             216 - 960                       200                                         46.0
                             above 960                       500                                         49.0



5.4.3. Restricted bands of operation, §15.205
                  MHz                            MHz                                MHz                                 GHz
 0.090-0.110                      16.42-16.423                         399.9-410                          4.5-5.15
 0.495-0.505                      16.69475-16.69525                    608-614                            5.35-5.46
 2.1735-2.1905                    16.80425-16.80475                    960-1240                           7.25-7.75
 4.125-4.128                      25.5-25.67                           1300-1427                          8.025-8.5
 4.20725-4.20775                  37.5-38.25                           1645.5-1646.5                      9.3-9.5
 6.215-6.218                      73-74.6                              1660-1710                          10.6-12.7
 6.26775-6.26825                  74.8-75.2                            1718.8-1722.2                      13.25-13.4
 6.31175-6.31225                  108-121.94                           2200-2300                          14.47-14.5
 8.291-8.294                      123-138                              2310-2390                          15.35-16.2
 8.362-8.366                      149.9-150.05                         2483.5-2500                        17.7-21.4
 8.37625-8.38675                  156.52475-156.52525                  2690-2900                          22.01-23.12
 8.41425-8.41475                  156.7-156.9                          3260-3267                          23.6-24.0
 12.29-12.293                     162.0125-167.17                      3332-3339                          31.2-31.8
 12.51975-12.52025                167.72-173.2                         3345.8-3358                        36.43-36.5
 12.57675-12.57725                240-285                              3600-4400                          --
 13.36-13.41                      322-335.4                            --                                 --
 Remark: only spurious emissions are allowed within these frequency bands not exceeding the limits per §15.209




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 16 of 25


5.4.4. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
General measurement procedures                Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”



5.4.5. MEASUREMENT RESULTS

The results are presented below in summary form only. For more information please see diagrams.

Table of measurement results:

  Dia-      Carrier Channel                                 Set-        OP-                                  Used detector         Result
  gram                            Frequency range            up         mode             Remark
   no.                                                      no.          no.
                  Range                                                                                     PK      AV     QP

  3.06          Nominal           30 MHz – 1 GHz              1           1                 --                                    Pass

Remark: 1.) For further details please refer diagrams in separate annex A1




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 17 of 25


5.5. Frequency error (tolerance)
5.5.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location      CETECOM Essen (Chapter. 2.2.1)      Please see Chapter. 2.2.2              Please see Chapter. 2.2.3
test site          441 EMI SAR  487 SAR NSA           337 OATS          347 Radio.lab.                      
receiver           377 ESCS30        001 ESS                                                                
spectr. analys.    489 ESU40         584 FSU8                                                               
antenna            048 EMCO3143  133 EMCO3115         302 BBHA9170  289 CBL 6141            030 HFH-Z2  431 Model 7405
signaling          298 CMU           460 CMU          295 RACAL         392 MT8820A                         
power supply       456 EA 3013A  457 EA 3013A         459 EA 2032-50  268 EA- 3050          494 AG6632A  498 NGPE 40
otherwise          331 HC4055        401 FTC40x15E    627 OPUS1                              477 GPS         
line voltage       230 V 50 Hz via public mains        060 120 V 60 Hz via PAS 5000

5.5.2. Standards and Limits: CFR 47, §15.225, ANSI 63.10: 2009 & RSS-210, Issue 9 Annex B.6
     Frequency             Frequency tolerance
                                                                          Remarks
       [MHz]           [%]        [ppm]        [Hz]
  13.553 -13.567      ±0.01        ±100       ±1356.7                         --


5.5.3. TEST SET-UP
A sniffer antenna acts like a coupling antenna for measuring the fundamental frequency. This is placed closed
the equipment which is situated inside an climatic chamber. Also connecting cables at the equipment are avoided
on the extent possible in order not to degrade the resonance frequency of the equipment and integral antenna.


5.5.4. EQUIPMENT SETTINGS

The measurements is made on nominal carrier frequency within operational band. Further settings on the
Spectrum-analyser can be checked on the screenshots attached.


5.5.5. TEST METHOD

A trace with low RBW function was recorded. The maximum peak within the span was found, then the
frequency deviation was recorded with the build-in frequency counter within the spectrum-analyser ESU40 to
minimize the measurement uncertainty.

The frequency deviation was recorded at switching on point of the equipment and on 2 minutes, 5 minutes and
10 minutes after at in accordance with ANSI 63.10: 2013, Chapter 6.8
All measurements data in graphical format are enclosed in annex 1.




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 18 of 25


5.5.5.1. Frequency shift of carrier against temperature at constant power supply voltage
1.) Use a full loaded battery for tests according this chapter
2.) determine the carrier frequency at room temperature and nominal voltage [20°C] after a long run of the
     device equipment (EUT). This frequency is taken as reference for all other measured frequencies.
3.) Perform the carrier frequencies measurements in 10°C increments from 50°C down to -20°C as required by
     the standards. The stabilization period was about 1 hour after thermal reach of the required temperature.

5.5.5.1.1. Results
                             Temperature Variation at Nominal Primary Supply Voltage
    Frequency error (tolerance) §15.225 & RSS 210                Set- up no.2        EUT OP-mode no. 2
                                                Nominal Conditions
   Vnom = 12.V DC                   Reference                            Limit->
   (from AE3 120 V AC / 60 Hz)                   13.5599346 MHz                      1355.99346      Hz
   Tnom = 21°C                      frequency                            100ppm:
                                         Extreme Temperature Conditions
                                  Measurement
                                     period        Frequency
         Temperature                                                         Frequency Error
                                  after power-      measured
                                  up the EUT
                                                     [MHz]              [Hz]           [%]          [ppm]
                                   on StartUp      13.5599127       21.9000000      0.000162         1.62
                                   2 Minutes       13.5599041       30.5000000      0.000225         2.25
          Tmax=50°C
                                   5 Minutes       13.5599016       33.0000000      0.000243         2.43
                                   10 Minutes      13.5598999       34.7000000      0.000256         2.56

                                   on StartUp       13.5599277          6.9000000      0.000051      0.51
                                   2 Minutes        13.5599160         18.6000000      0.000137      1.37
             T=40°C
                                   5 Minutes        13.5599129         21.7000000      0.000160      1.60
                                   10 Minutes       13.5599117         22.9000000      0.000169      1.69

                                   on StartUp       13.5599256          9.0000000      0.000066      0.66
                                   2 Minutes        13.5599252          9.4000000      0.000134      0.69
             T=30°C
                                   5 Minutes        13.5599249          9.7000000      0.000072      0.72
                                   10 Minutes       13.5599249          9.7000000      0.000072      0.72

                                   on StartUp       13.5599159          18.7000000     0.000138      1.38
                                   2 Minutes        13.5599742         -39.6000000     -0.000292    -2.92
             T=10°C
                                   5 Minutes        13.5599780         -43.4000000     -0.000320    -3.20
                                   10 Minutes       13.5599716         -37.0000000     -0.000273    -2.73

                                    StartUp         13.5599663         -31.7000000     -0.000234    -2.34
                                   2 Minutes        13.5600051         -70.5000000     -0.000520    -5.20
             T=0°C
                                   5 Minutes        13.5600036         -69.0000000     -0.000509    -5.09
                                   10 Minutes       13.5600029         -68.3000000     -0.000504    -5.04

                                    StartUp         13.5600037         -69.1000000     -0.000510    -5.10
                                   2 Minutes        13.5600114         -76.8000000     -0.000566    -5.66
            T=-10°C
                                   5 Minutes        13.5600120         -77.4000000     -0.000571    -5.71
                                   10 Minutes       13.5600122         -77.6000000     -0.000572    -5.72

                                  StartUp          13.5599891          -54.5000000     -0.000402    -4.02
                                 2 Minutes         13.5599936          -59.0000000     -0.000435    -4.35
         T=-20°C
                                 5 Minutes         13.5599979          -63.3000000     -0.000467    -4.67
                                10 Minutes          13.560001          -66.4000000     -0.000490    -4.90
Remark: 1.) For further details please refer diagrams in separate annex A1
VERDICT:        Pass




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 19 of 25


                               Variation in the Supply Voltage at Temperature of 20°C
   Frequency error (tolerance) §15.225 & RSS 210                  Set- up no.2          EUT OP-mode no. 2
                                                 Nominal Conditions
   Vnom = 12.V DC                   Reference                              Limit->
   (from AE3)                                     13.5599346 MHz                        1355.99346     Hz
   Tnom = 20°C                      frequency                              100ppm:
                        Extreme Voltage Conditions of Rated Primary Supply Voltage
                              Measurement
                                  period        Frequency
      Supply Voltage                                                       Frequency Error
                              after power-       measured
                              up the EUT
                                                  [MHz]               [Hz]           [%]              [ppm]
                               on StartUp       13.5599253         9.3000000      0.000069             0.69
   85% of Rated Primary         2 Minutes       13.5599250         9.6000000      0.000071             0.71
      Supply Voltage            5 Minutes       13.5599246        10.0000000      0.000074             0.74
    (AE3: 108 V AC / 60 Hz)
                               10 Minutes       13.5599247         9.9000000      0.000073             0.73

       115% of Rated                on StartUp       13.5599269           7.7000000      0.000057     0.57
       Primary Supply               2 Minutes        13.5599252           9.4000000      0.000069     0.69
          Voltages                  5 Minutes        13.5599241          10.5000000      0.000077     0.77
     (AE3: 138 V AC / 60 Hz)        10 Minutes       13.5599238          10.8000000      0.000080     0.80

Remark: 1.) For further details please refer diagrams in separate annex A1
VERDICT:        Pass




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 20 of 25


5.6. Measurement uncertainties
The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved. For uncertainty determination,
each component used in the concrete measurement set-up was taken in account and it contribution to the overall
uncertainty according it’s statistical distribution calculated.

                                                       Calculated uncertainty based
     RF-Measurement          Reference         Frequency range                                       Remarks
                                                       on a confidence level of 95%
Conducted emissions                 9 kHz - 150 kHz  4.0 dB
                       CISPR 16-2-1                                                                      -
(U CISPR)                           150 kHz - 30 MHz 3.6 dB
Radiated emissions                  30 MHz - 1 GHz   4.2 dB
                       CISPR 16-2-3                                                                   E-Field
Enclosure                           1 GHz - 18 GHz   5.1 dB
Disturbance power      CISPR 16-2-2 30 MHz - 300 MHz -                                                   -
Power Output radiated       -       30 MHz - 4 GHz   3.17 dB                                     Substitution
Power Output conducted      -       9 kHz - 20 GHz   1.0 dB                                              -
Conducted emissions         -       9 kHz - 20 GHz   1.0 dB                                              -
on antenna ports                    20 GHz - 40 GHz
                                                     0.1272 ppm (Delta Marker)                   Frequency error
Occupied bandwidth          -       9 kHz - 4 GHz
                                                     1.0 dB                                      Power
                            -                        0.1272 ppm (Delta Marker)                   Frequency error
Emission bandwidth                  9 kHz - 4 GHz
                            -                        1.0 dB                                      Power
Frequency stability         -       9 kHz - 20 GHz   0.0636 ppm                                          -
                                    150 kHz - 30 MHz 5.0 dB                                      Magnetic field
Radiated emissions
                            -       30 MHz - 1 GHz   4.2 dB                                      E-field
Enclosure
                                    1 GHz - 20 GHz   3.17 dB                                     Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 21 of 25




6. Accreditation details of CETECOM’s laboratories and test sites

Ref.-   Accreditation                Valid for laboratory area or test site
No.      Certificate                                                                    Accreditation Body
-          D-PL-                                                                  DAkkS, Deutsche
                        All laboratories and test sites of CETECOM GmbH, Essen
        12047-01-01                                                               Akkreditierungsstelle GmbH
337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                  FCC, Federal Communications
487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
     MRA US-EU                                                                    Commission
558                 Radiated Measurements above 1 GHz, 3 m (FAR)
         0003                                                                     Laboratory Division, USA
348                 Mains Ports Conducted Interference Measurements
348                 Telecommunication Ports Conducted Interference Measurem.
337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)              IC, Industry Canada Certification
550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)               and Engineering Bureau
558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                  VCCI, Voluntary Control Council
550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                  for Interference by Information
348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                  Technology Equipment, Japan
348     T-1967      Telecommunication Ports Conducted Interference Measurem.
OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 22 of 25




7. Instruments and Ancillary
7.1. Used equipment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


7.1.1. Test software and firmware of equipment
 Ref.-No.




                           Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                   UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295         Racal Digital Radio Test Set              6103                     1572
                                                                                                   SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                   R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                   all band used
323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                   Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                   4.52#002
                                                                                                   R&S Test Firmware Base=5.14, Mess-Software=
436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                   GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                      System CTC-FAR-EMI-
443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                      RSE
444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                   R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                   f. all band used, GSM = 5.14 WCDMA: = 5.14
584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                   R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                   not installed, Mainboard= µP1=V.850
598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670         Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689         Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                   CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692         Bluetooth Tester                          CBT 32                   100236
                                                                                                   RF)




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 23 of 25



7.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                          calibration
                                                                                                                          Interval of



                                                                                                                                            Remark
                           Equipment                           Type                 Serial-No.        Manufacturer                                       Cal
                                                                                                                                                         due

001         EMI Test Receiver                         ESS                      825132/017        Rohde & Schwarz          12 M          -            30.05.2017
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                  861741/005        Rohde & Schwarz          12 M          -            30.05.2017
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  892563/002        Rohde & Schwarz          12 M          -            30.05.2017
009         Power Meter (EMS-radiated)                NRV                      863056/017        Rohde & Schwarz          24 M          -            30.04.2017
016         Line Impedance Simulating Network         Op. 24-D                 B6366             Spitzenberger+Spies      36 M          -            30.05.2019
020         Horn Antenna 18 GHz (Subst 1)             3115                     9107-3699         EMCO                     36/12 M       -            31.03.2017
021         Loop Antenna (H-Field)                    6502                     9206-2770         EMCO                     36 M          -            30.04.2018
030         Loop Antenna (H-field)                    HFH-Z2                   879604/026        Rohde & Schwarz          36 M          -            30.04.2018
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                  879581/18         Rohde & Schwarz          24 M          -            30.04.2017
057         relay-switch-unit (EMS system)            RSU                      494440/002        Rohde & Schwarz          pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                 B6363             Spitzenberger+Spies      -             3
                                                      WRCT 1900/2200-5/40-
066         notch filter (WCDMA; FDD1)                                         5                 Wainwright GmbH          12 M          1g           30.06.2016
                                                      10EEK
086         DC - power supply, 0 -10 A                LNG 50-10                -                 Heinzinger Electronic    pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S                -                 Elektro Automatik        pre-m         2
091         USB-LWL-Converter                         OLS-1                    007/2006          Ing. Büro Scheiba        -             4
099         passive voltage probe                     ESH2-Z3                  299.7810.52       Rohde & Schwarz          36 M          -            30.04.2018
100         passive voltage probe                     Probe TK 9416            without           Schwarzbeck              36 M          -            30.04.2018
110         USB-LWL-Converter                         OLS-1                    -                 Ing. Büro Scheiba        -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547            BOCONSULT                36 M          -            30.05.2019
136         adjustable dipole antenna (Dipole 1)      3121C-DB4                9105-0697         EMCO                     36 M          -            30.04.2018
140         Signal Generator                          SMHU                     831314/006        Rohde & Schwarz          24 M          -            30.05.2018
248         attenuator                                SMA 6dB 2W               -                 Radiall                  pre-m         2
249         attenuator                                SMA 10dB 10W             -                 Radiall                  pre-m         2
252         attenuator                                N 6dB 12W                -                 Radiall                  pre-m         2
256         attenuator                                SMA 3dB 2W               -                 Radiall                  pre-m         2
257         hybrid                                    4031C                    04491             Narda                    pre-m         2
260         hybrid coupler                            4032C                    11342             Narda                    pre-m         2
261         Thermal Power Sensor                      NRV-Z55                  825083/0008       Rohde & Schwarz          24 M          -            30.05.2018
262         Power Meter                               NRV-S                    825770/0010       Rohde & Schwarz          24 M          -            30.05.2018
263         Signal Generator                          SMP 04                   826190/0007       Rohde & Schwarz          36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04        840414/009        Rohde & Schwarz          24 M          -            30.05.2018
266         Peak Power Sensor                         NRV-Z31, Model 04        843383/016        Rohde & Schwarz          24 M          -            30.05.2018
267         notch filter GSM 850                      WRCA 800/960-6EEK        9                 Wainwright GmbH          pre-m         2
270         termination                               1418 N                   BB6935            Weinschel                pre-m         2
271         termination                               1418 N                   BE6384            Weinschel                pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                 BF6239            Weinschel                pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                 BF9229            Weinschel                pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W    BG0321            Weinschel                pre-m         2
275         DC-Block                                  Model 7003 (N)           C5129             Weinschel                pre-m         2
276         DC-Block                                  Model 7006 (SMA)         C7061             Weinschel                pre-m         2
279         power divider                             1515 (SMA)               LH855             Weinschel                pre-m         2
287         pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P     379418            Miteq                    12 M          1c           30.06.2017
291         high pass filter GSM 850/900              WHJ 2200-4EE             14                Wainwright GmbH          12 M          1c           30.06.2017
298         Univ. Radio Communication Tester          CMU 200                  832221/091        Rohde & Schwarz          pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                  892 239/020       Rohde & Schwarz          12 M          -            30.05.2017
301         attenuator (20 dB) 50W, 18GHz             47-20-33                 AW0272            Lucas Weinschel          pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                 155               Schwarzbeck              36 M          -            31.03.2017
303         horn antenna 40 GHz (Subst 1)             BBHA9170                 156               Schwarzbeck              36 M          -            31.03.2017
331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146             Heraeus Vötsch           Pre-m         2
341         Digital Multimeter                        Fluke 112                81650455          Fluke                    24 M          -            30.05.2018
342         Digital Multimeter                        Voltcraft M-4660A        IB 255466         Voltcraft                24 M          -            30.04.2017
347         laboratory site                           radio lab.               -                 -                        -             5
348         laboratory site                           EMI conducted            -                 -                        -             5
354         DC - Power Supply 40A                     NGPE 40/40               448               Rohde & Schwarz          pre-m         2
355         Power Meter                               URV 5                    891310/027        Rohde & Schwarz          24 M          -            30.05.2018
357         power sensor                              NRV-Z1                   861761/002        Rohde & Schwarz          24 M          -            30.04.2017
371         Bluetooth Tester                          CBT32                    100153            R&S                      36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  100535            Rohde & Schwarz          12 M          -            30.05.2017
377         EMI Test Receiver                         ESCS 30                  100160            Rohde & Schwarz          12 M          -            30.05.2017
389         Digital Multimeter                        Keithley 2000            0583926           Keithley                 24 M          -            30.04.2017
392         Radio Communication Tester                MT8820A                  6K00000788        Anritsu                  12 M          -            30.05.2017
431         Model 7405                                Near-Field Probe Set     9305-2457         EMCO                     -             4
436         Univ. Radio Communication Tester          CMU 200                  103083            Rohde & Schwarz          12 M          -            30.04.2017
439         UltraLog-Antenna                          HL 562                   100248            Rohde & Schwarz          36 M          -            31.03.2017
                                                      System CTC-FAR-EMI-                        ETS-Lindgren /
443         CTC-FAR-EMI-RSE                                                    -                                          12 M          5            30.06.2017
                                                      RSE                                        CETECOM
                                                      WRCT 1850.0/2170.0-                        Wainwright Instruments
448         notch filter WCDMA_FDD II                                          5                                          12 M          1c           30.06.2017
                                                      5/40-                                      GmbH
                                                      WRCT 824.0/894.0-5/40-
449         notch filter WCDMA FDD V                                           1                 Wainwright               12 M          1c           30.06.2017
                                                      8SSK



TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 24 of 25


 Ref.-No.




                                                                                                                                  calibration
                                                                                                                                  Interval of



                                                                                                                                                    Remark
                             Equipment                           Type                     Serial-No.              Manufacturer                                   Cal
                                                                                                                                                                 due

454         Oscilloscope                              HM 205-3                    9210 P 29661            Hameg                   -             4
456         DC-Power supply 0-5 A                     EA 3013 S                   207810                  Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50               910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                     108901                  Rohde & Schwarz         12 M          -            30.04.2017
463         Universal source                          HP3245A                     2831A03472              Agilent                 -             4
466         Digital Multimeter                        Fluke 112                   89210157                Fluke USA               24 M          -            30.05.2018
467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA               36 M          -            30.04.2018
468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA               36 M          -            30.04.2018
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink   -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz         24 M          -            30.04.2017
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)           -             1d
                                                      AMF-5D-02501800-25-
484         pre-amplifier 2,5 - 18 GHz                                            1244554                 Miteq                   12 M          -            30.06.2017
                                                      10P
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                               24 M          -            31.07.2017
                                                      NSA                                                 CETECOM
489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz         12 M          -            30.05.2017
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright              pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright              pre-m         2
                                                      WRCA 800/960-02/40-
512         notch filter GSM 850                                                  SN 24                   Wainwrght               12 M          1c           30.06.2017
                                                      6EEK
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                 24 M          -            30.04.2017
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel               pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                       pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                     12 M          -            30.05.2017
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz         12 M          -            30.04.2017
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz         36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                               -                                               24 M          -            31.07.2017
            EMI                                       VSWR                                                Lindgren/CETECOM
552         high pass filter 2,8-18GHz                WHKX 2.8/18G-10SS           4                       Wainwright              12 M          1c           30.06.2017
557         System CTC-OTA-2                          R&S TS8991                  -                       Rohde & Schwarz         12 M          5            30.09.2016
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                     24 M          -            19.04.2017
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia               36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz         pre-m         -
594         Wideband Radio Communication Tester       CMW 500                     101757                  Rohde & Schwarz         12 M          -            30.04.2017
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz         pre-m         -
598         Spectrum Analyzer                         FSEM 30 (Reserve)           831259/013              Rohde & Schwarz         24 M          -            30.04.2017
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz         24 M          -            30.04.2017
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz         24 M          -            30.04.2017
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz         24 M          -
611         DC power supply                           E3632A                      KR 75305854             Agilent                 pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                 pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                 pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                   24 M          -            30.05.2018
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits           -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA      -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA     -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz           12 M          -            30.05.2017
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz         pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                 -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH           24 M          -            30.04.2017
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz         pre-m         2
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                -             2
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits           -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz         24 M          -            30.05.2018
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik       pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz           pre-m         -
683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz         12 M          -            30.05.2017
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                      24 M          -            30.04.2017
                                                                                                          Solutions
687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz           12 M          -            30.05.2017
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                   pre-m         -
690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz           12 M          -            30.05.2017
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz         36 M          -            31.03.2017
697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits           -             2




TR2-20842790-15-11a


Test Report 2-20842790-15-11a, Page 25 of 25



      7.1.3. Legend


Note / remarks                       Calibrated during system calibration:
                           1a        System CTC-SAR-EMS (Ref.-No. 442)
                           1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                           1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                           1d        System CTC-SAR-EMI (Ref.-No . 441)
                           1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                           1f        System CTC-CTIA-OTA (Ref.-No . 420)
                           1g        System CTC-FAR-EMS (Ref.-No . 444)
                           2         Calibration or equipment check immediately before measurement
                           3         Regulatory maintained equipment for functional check or support purpose
                           4         calibration of this equipment
                                     Ancillary equipment   without has no effect
                                                                   calibration   onmechanical
                                                                               e.g. measuring result
                                                                                              equipment or monitoring equipment
                           5         Test System


Interval of calibration    12 M      12 month
                           24 M      24 month
                           36 M      36 month
                           24/12 M   Calibration every 24 months, between this every 12 months internal validation
                           36/12 M   Calibration every 36 months, between this every 12 months internal validation
                           Pre-m     Check before starting the measurement
                           -         Without calibration




8. Versions of test reports (change history)

      Version             Applied changes                                                                                         Date of release
        --                Initial release                                                                                          2016-12-05
        --                --                                                                                                            --




TR2-20842790-15-11a



Document Created: 2016-12-05 10:33:13
Document Modified: 2016-12-05 10:33:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC