Manual - YRT220-ZB

FCC ID: U4A-YRHCPZB0

Users Manual

Download: PDF
FCCID_1641561

                          Certification Exhibit



                          FCC ID: U4A-YRHCPZB0
                           IC: 6982A-YRHCPZB0

                     FCC Rule Part: 15.247
           IC Radio Standards Specification: RSS-210

                      ACS Project Number: 12-0001

                Manufacturer: Assa Abloy Inc.
Models: YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB




                      Manual – YRT220-ZB




       5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                 Yale Real Living™ Touchscreen Lever
                               Installation and Programming Instructions


                                                                             NOTE TO INSTALLER

                                                                             FAILURE TO FOLLOW THESE INSTRUCTIONS
                                                                             COULD RESULT IN DAMAGE TO THE PRODUCT
                                                                             AND VOID THE FACTORY WARRANTY




                                   For Technical Assistance call Yale at 1-800-810-WIRE (9473)

                  This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.
                            Click "Product Information & Documentation" and then "Installation Instructions".

                 Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.
                       Presione "Información del Producto y Documentación" y luego "Instrucciones de Instalación".

                  Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com.
                       Cliquez sur le "Information sur le produit et Documentation" et puis "Installation Instructions".


                                                                                                            P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                          TABLE OF CONTENTS

            Warnings..........................................................................................................................2
                 Return Lock to Factory Default.................................................................................3
            Introduction......................................................................................................................3
            Installation
                 Components and Tools..............................................................................................4
                 Prepare Lock for Installation.................................................................................. 5-6
                 Install Lock........................................................................................................... 6-11
            Programming
                 Programming Features-Menus-Keys-Definitions.............................................. 12-13
                 Operation........................................................................................................... 14-16
            Miscellaneous Information
                 Hardware Troubleshooting .....................................................................................17
                 Programming Troubleshooting................................................................................18
                 Installing the Network Module ...............................................................................19
                 Sample Pin Code Management Sheets............................................................ 23-24

                                                                   WARNINGS

             Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc.
             could void the user's authority to operate the equipment.
            IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and
            security of this product. Misalignment can cause performance degradation and a lessening of
            security.
            Finish Care: This lockset is designed to provide the highest standard of product quality and perfor-
            mance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp
            cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coat-
            ing and result in tarnishing.

            FCC:
            FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)
            Model(s): YRT220-ZW, YRT220-ZB
            This equipment has been tested and found to comply with the limits for a Class B digital device,
            pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
            harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
            frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
            interference to radio communications. However, there is no guarantee that interference will not occur in a
            particular installation. If this equipment does cause harmful Interference to radio or television reception,
            which can be determined by turning the equipment off and on, the user is encouraged to try to correct
            the interference by one or more of the following measures:
                 • Reorient or relocate the receiving antenna.
                  •     Increase the separation between the equipment and receiver.
                  •     Connect the equipment into an outlet on a circuit different from that to which the receiver
                        is connected.
                  •     Consult the dealer or an experienced radio/TV technician for help.



                                                                                                                                                  2
                                                                                                                         P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


            To reset the lock to factory default, see the following:
                    Reset Lock to Factory Default
                                                                                              Reset Button
               The following procedure returns the lock to its factory defaults
               by deleting all user codes (including the Master PIN code*) and
               returning all programming features to their original default settings
               (see below).
               1. Remove the batteries and then remove the inside escutcheon
                  to access the reset button.
               2. The reset button (see image at right) is located above the
                  PCB cable connector.
               3. Hold down the reset button for a minimum of 3 seconds and
                  then reinstall the batteries; once the batteries are properly
                  installed, release the reset button.
               All features (including adjustable settings** (see below) should
               now be returned to factory default.
               Upon reset, Master Code Registration is the only option available
               and must be performed prior to any other programming of the lock.
               See "Operation" later in this manual for programming instructions.              Inside Escutcheon



                    Factory Default Settings
                                             Settings                    Factory Default

                                           Master Code                Registration required

                                           Auto Re-lock                     Enabled

                                        One Touch Re-Lock                   Enabled

                                               Audio                        Enabled

                                        Auto Re-lock Time                **30 Seconds

                                      Wrong Code Entry Limit               **5 Times

                                          Shutdown Time                  **60 Seconds

                                   **Adjustable only when using Network Module




                                                                                                                      3
                                                                                               P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


        Industry Canada:
        Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)
        Model(s): YRT220-ZW, YRT220-ZB

        This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment
        Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful
        interference, and (2) this device must accept any interference received, including interference that may
        cause undesired operation.

        Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne
        causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce
        dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle
        interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

        For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:
        “This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
        environment. This equipment should be installed and operated with minimum distance 20cm between
        the radiator and your body. This transmitter must not be co-located or operating in conjunction with any
        other antenna or transmitter.”

        Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate
        using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
        Canada. To reduce potential radio interference to other users, the antenna type and its gain should be
        so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
        successful communication.
        En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne
        d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour
        réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies
        de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
        pour une communication réussie.
        Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s).
        Operation is subject to the following two conditions: 1) this device may not cause interference, and 2)
        this device must accept any interference, including interference that may cause undesired operation of
        the device.
        Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
        fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des
        interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
        causer un mauvais fonctionnement du dispositif.

                                                     INTRODUCTION

       The Yale Real Living™ Stand-alone Touchscreen Deadbolt Lock combines a robust lockset with a
       contemporary electronic aesthetic.
       Users benefit from an interactive touchscreen that makes day-to-day access effortless, as well as
       offering voice-guided programming for simple updates to user information in the event of staffing
       changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and
       fits in place of a standard deadbolt lock door prep (ANSI/BHMA A156.115).
       If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network
       controller. That distance is influenced by objects between the lock and the controller and may be
       expanded depending on proximity to other RF network devices. Also, if the lock is connected to a
       network controller, it is recommended that it is programmed through the centralized user interface
       (PC or hand-held device) to ensure communication between the lock and the controller unit.
                                                                                                                           4
                                                                                                    P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                      INSTALLATION

                                                     COMPONENTS AND TOOLS

              Included in the box. . .
                 Installation Instructions              Inside Mounting Plate                               Keys
                                                        (with gasket)                                       Cylinder
                 Template
                                                        Inside Escutcheon                                   Battery Cover
                 Latch Bolt
                                                        Outside Escutcheon                                  Allen Wrench
                 Strike Plate
                                                        (2) Screw Packs (see below)                         4 AA Alkaline Batteries




              Parts Illustrations




                                                                                                                                 4 AA Alkaline
                                                                                                                                   Batteries
                                                                                                        Battery Cover


                                                      Latch




                                                                                 Inside              Network Module
                                   Outside                                                              (Optional)               Latch bolt
                                                                               Escutcheon
                                 Escutcheon                                                                                        Strike
                                                  Allen Wrench                                       Keys
                                               (2) Hex Set Screws
                                                     (Pack 1)


                                                                     (2) Inside Mounting Plate Screws
      Inside Mounting Plate                                                      (Pack 1)                                       Cylinder
           with Gasket
   (back of Inside Escutcheon)       Outside & Inside Lever
                                            Handles
                                                                                                               (4) Inside Escutcheon
                                                                    (2) Latch & (2) Strike Plate Mounting        Mounting Screws
                                                                              Screws (Pack 2)                          (Pack 1)

               Tools Needed
            Door Prep                                                    Lock Installation
              ƒƒ 2-1/8" (54mm) hole saw                                    ƒƒ #2 Phillips screw driver
              ƒƒ 1" (26mm) boring bit                                      ƒƒ Allen wrench (3mm) - provided
              ƒƒ 7/64" (2.5mm) drill bit
              ƒƒ Chisel & hammer


                                                                                                                                                 5
                                                                                                                        P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                     INSTALL LOCK


               Install Latch
              The lock is packed representative of how it will install on the door.
              Before installing the lock on the door:
        A. Remove the latch (Fig. 1) and strike plate from the packaging.
         NOTE: Latch ships with backset in 2-3/8" position (Fig. 1).
                    Backset is the measurement from door edge to center
                    of 2-1/8" diameter hole (see template supplied with lock).
        If required, pull to extend to 2-3/4" backset position (Detail 1A).
        NOTE: Different holes are used for (2) through bolts depending on backset (see Detail 1A).


                                                                                  2-3/8" through bolt posts




                                       Figure 1
                                                                                  2-3/4" through bolt posts



                                                                                          Detail 1A


        NOTE: Make sure door has been prepped according to specifications in template included
              with lock.
        NOTE: The latch bolt (and strike) can be installed in only one of two ways -
              with the bevel (slope) of latch facing out or facing in while standing
              outside of the door.
        If the door opens in, the bevel will face the outside; if the doors opens out, the
        bevel will face in.
        The strike plate is installed according to the orientation of the latch bolt. See
        Figures 1 & 2 for an example of a RH door that opens in.

        NOTE: Both latch face and strike plate have adhesive-backed covers to
              prevent marring and should be removed upon installation.

      B. Install latch bolt in door.
        1. Attach with two (2) M4 x 25.4mm screws supplied.
      C. Install strike on the door frame, using two (2) M4 x 25mm                          (4) M4 x 25.4mm      Figure 2
         screws supplied, making sure to allow for the latch to be                          Flat Head
                                                                                            Combination Screws
         centered in the strike.

                                                                                                                            6
                                                                                                  P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                  Install Outside Escutcheon

             NOTE: The "tops" of both the square drive tube and the hub (in the shank) are marked to
                   indicate their orientation for proper installation (Figures A & B).




                                                                                            NOTE: RED marking
                                                                                           indicates "top" of hub
                                                                                                                        Clip




                  Shank
                                                                      Square
                                                                    Drive Tube
                                                                    is marked
                                                                    (WHITE) to
                                                                     indicate
                                                                       "top"
                                                                                              Shank
                                                      Figure A                                             Figure B
                      Outside Escutcheon
                         (with gasket)


                               Do not remove clip from Outside Escutcheon shank until correct handing has
                               been determined and Outside Lever Handle is to be installed.
                               (See page 9)

                  1. From outside of door, position the outside escutcheon by first routing the cable
                     through 2-1/8" diameter hole and under the latch (Fig. 3A & B), then insert
                     posts* and tailpiece into the latch.



                                                                          Inside of Door
                                                                                                              "Top" of Drive Tube
                                                                                                               (marked WHITE)




                                                                                               Figure 1B
                       Tailpiece
                                    Outside of Door                     NOTE: Cable goes
                                   Figure 1A
                                                                       under latch (Fig. 1A & 1B).


                     *Posts are inserted in holes according to
                     backset adjustment. (Refer back to Detail 1A
                     under "Install Lock")


                                                                                                                                           7
                                                                                                                    P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                  Install Outside Escutcheon
              2. Remove the inside mounting plate (with gasket) from
                 the back (door side) of the inside escutcheon (Fig. 2A).



                                                                 A. Ensure that gasket on
                                                                    inside mounting plate
                                                                    is properly fitted (Fig. 2B).




                                                            Figure 2A




                            Inside Escutcheon & Mounting Plate                                               Figure 2B
                                       (with gasket)


              3. Remove the battery cover from the back of the inside escutcheon (Fig. 3) by loosening
                 the captive Phillips head screw.


                                                                                                    Screw




                                                                                          Battery Cover


                                                          Figure 3                                                Inside of Door



               4. Holding the outside escutcheon flush to the door,
                  position the inside mounting plate by routing the
                  cable/connector through the mounting plate's 1/2"
                  rectangular hole below center hole (Fig. 4A).
               5. Secure both assemblies by inserting (2) M4 x 25mm
                  pan head machine screws through the mounting
                                                                                                                      Figure 4A
                  plate and into the slightly extended through posts of
                  the outside escutcheon (Fig. 4B).
                    Ensure that outside escutcheon is vertically aligned.                            Through posts here

                    Tighten securely with a #2 Phillips screwdriver.
                    Do not over-tighten.
                6. Finish routing the cable and connector through the left
                   upper slot, then behind center rib as shown in Fig. 4A.
                                                                                                          Figure 4B




                                                                                                                                      8
                                                                                                               P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


            7. Attach cable assembly to the inside escutcheon printed circuit board (PCB) by lining up
               notches on top of cable connector to slots on PCB connector (Fig. 7A & 7B).
                 Press connector in firmly using thumbs until completely seated (properly seated position
                 indicated by arrows on PCB as in Fig. 7B).

                                                     Reset Button


                 Inside Escutcheon




         Cable Connector




                                                                      Figure 7B



                                         Figure 7A


              8. Install and secure inside escutcheon to inside mounting plate using (4) M4 x 8mm
                 [8-32 x 5/16"] pan head machine screws through the inside escutcheon into the
                 mounting plate (Fig. 8).
                  NOTE: Make sure cable does not obstruct path of the mounting screws.




                                                                         Figure 8




                                                                                                                   9
                                                                                            P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


           Determine Lever Handing




                            Hinges on Right                            Hinges on Left
                            Right handed                               Left handed
                            lever position                             lever position
              RH                                                                                   LH
              RHR                                                                                  LHR
              Lever               ƒƒ Both outside and inside lever handles should                  Lever
                                     always point toward the door hinges.




            Determine Lever Position




                                  Correct "curved" position       Correct "curved" position




                             Incorrect                                                Incorrect



            Before proceeding with the next step, ensure correct lever handing for proper installation.




                                                                                                                    10
                                                                                              P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                Install the Exterior Lever (Right Hand shown)

            1. Install cylinder in exterior lever.                                                         Tailpiece



                    (If necessary, remove key from cylinder)
               A. Drop cylinder in exterior lever handle as shown.
                                                                                    Figure 1A



               B. Insert key in cylinder.
                   While supporting cylinder tailpiece (with finger);                    90°

                   rotate key 90° clockwise (CW) to vertical position
                   (Figure 1B).
                                                                                                     Figure 1B
                   NOTE: RH shown; with LH lever, rotate key 90°
                   counter-clockwise (CCW)

            2. Remove clip from shank.

                A. Once correct handing is determined, remove the
                   clip that has held the hub in its correct position by
                   spreading clip ends to extract clip from shank as
                   shown in Figure 1C with detail.
                Do not rotate cam from its original position.
                		          ("top" is marked RED)


                                                                                               Figure 1C
            3. Install hex set screw.
                   NOTE: For correct lever handing, the
                         hex set screw for the outside
                         lever shank must be installed
                         as shown (Fig. 8B).
                   A. Place set screw in hole on side of 		                             Hex Screw
                      shank toward edge of door (opposite
                      lever handle); turn CW to allow placement
                      of lever handle over shank.
                      Do not overtighten.
                                                                               RH/RHR                  LH/LHR



                                                                        Figure 8B




                                                                                         CW



                                                                                                                           11
                                                                                                    P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


         E. Push lever handle (with key & cylinder)
            over shank until hole on handle aligns
            with set screw in shank (Figure 1E).




                                                                                  E




                                                                                      Figure 1E




         F. Secure lever handle by inserting allen wrench and rotating set screw CCW (Fig. 1F).
             Do not overtighten.
         G. Turn key 90° CCW; pull to remove key and test operation of lever handle, ensuring
            that the latch moves smoothly.




                                                             90°
                                                 CCW




                            Figure 1F
                                                  F

                                                                   G



                                                                                                                   12
                                                                                             P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                 Install the Exterior Lever (Right Hand shown)
                   1. Rotate thumbturn counter-clockwise to horizontal position (Fig. 9A).




                                                    Figure 9A



                   2. Insert set screw on side of shank (toward        3. Turn set screw CCW to tighten
                      edge of door); turn CW to allow placement            and secure lever handle to shank.
                      of inside lever handle over shank.




                                                        Figure 9B                                  Figure 9C




                   IMPORTANT: Before installing the batteries, test the mechanical operation of lock
                   by rotating both the outside and inside lever handles. Also try using both the thumbturn
                   and key. The movement of the latch should be smooth and unobstructed.
                   If operation is not smooth, review the previous steps to ensure proper installation, while
                   maintaining proper alignment of escutcheons.

                       Install Batteries

                  1. Insert four (4) AA alkaline batteries; the lock
                     will flash and beep several times.


                   2. Install battery cover and tighten Phillips
                      head screw.




                                                                                                                      13
                                                                                               P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                        PROGRAMMING

                  Programming Features-Menus-Keys-Definitions.............................................. 12-13
                  Operation........................................................................................................... 14-17


                             PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS


               Outside                                                                 Inside

                                                     " P " Key
           Touch Screen                                                                                Phillips Screw
                                                     (Return to Previous)
                                                                                                         Battery Cover

                                                                                                                            Network Module Slot

                                                     Numbers
           Low Battery                                                                                                      Alkaline Batteries
             Indicator
                                                     Lockout Mode                                                           4 AA Type
                                                                                                                            Status Indicator
                                                     Cylinder
                                                                                   Inside Handle




                                                Speaker Hole




                Menu and Icons

                                   Touch the screen with palm of hand or                           Repeat operation using settings indicated.
                                   fingers to begin and end actions.                               Enter Value 1 -10 (times or seconds).
                                                                                   M            Enter Master PIN code* (4-8 digits in length).
                         ~         Click the indicated number.
                                                                                                Advanced Mode only.

                                   Press the Star key on the touchscreen to        U            Enter User PIN. Can be 4-8 digits in length.
                                   Enter or Accept entry.
                                   Press the Pound key on the touchscreen to                    User Serial Number (01 - 25);
                                   enter Menu mode.                                             RF Controlled (01-250).
                                   Press this key to return to the previous
                                   step or menu setting.




             *The Master Pin Code must be registered prior to any further programming of the lock.




                                                                                                                                                  14
                                                                                                                            P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


             Status Indicators
                  1   Low Battery Warning                       2    Lockout Mode                           3   Return to previous step




            Definitions
             Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user PIN
             code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator
             flashes RED and BLUE; the keypad flashes as well.
             Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power is
             completely lost, use the key override.
             Master PIN Code: The Master code is used for programming and for feature settings. NOTE: The
             Master Pin Code must be registered prior to programming the lock. The Master code will also
             operate the lock.
             Auto Re-lock Time: After successful code entry and the unit unlocks, it will automatically re-lock
             after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to thirty (30) seconds.
            One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt
            (during Auto Re-Lock duration or when Auto Re-Lock is disabled).
             Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow operation
             after the wrong code entry limit has been met. When the unit is in Shutdown, the Status Indicator
             flashes RED and BLUE; the keypad flashes as well.
             Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone playback
             for use in quiet areas. Audio mode is enabled or disabled through feature programming by the
             Master code.
             Status LED: Located on inside escutcheon.
             User PIN Code: The User code operates the lock. Maximum number of user codes is 250 with
             Network Module; without Network Module, maximum is 25 user codes.
             Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a valid
             PIN code the unit will shut down and not allow operation. Wrong code entry limit is adjustable from
             three (3) to ten (10) times through feature settings (up to 5 times with no RF network enabled - de-
             fault is 5; 10 with RF network enabled).

                                      Factory Default Settings
                                                   Settings                           Factory Default
                                                 Master Code                        Registration required
                                                 Auto Re-lock                             Enabled
                                              One Touch Re-Lock                           Enabled
                                                    Audio                                 Enabled
                                              Auto Re-lock Time                        **30 Seconds
                                            Wrong Code Entry Limit                       **5 Times
                                               Shutdown Time                           **60 Seconds
                                                                                                                                                             15
                                     *Adjustable with Network Module                                                                  P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                                   OPERATION


             Lock Activation

      The touchscreen can be activated in several ways:



          Touch lock with                              Touch lock with                     Press the            key to
          back of hand or                              fingers spread to                   activate.
          fingers to activate.                         activate.




              Lock Operation

              Master Code Set*
               1. Touch the screen with the back of your hand or fingers to activate                    .
               2. Press the          key.
                   Lock Response: “Register Master Code; press the                   key to continue.”
               3. Press the          key.
                   Lock Response: “Enter a 4 to 8 digit pin code followed by the pound key."
               4. Enter new 4-8 digit Master PIN code followed by the                  key.
               Lock visually confirms pin code selection, announces "Handing lock", the motor engages
               and the lock responds, "Completed".
             *This step is required prior to programming of the lock.

                            1
                             Press the      key.                           Enter the new Master PIN code (4~8
                                                                           digits), followed by the key.




                                                                                                                                       16
                                                                                                                 P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


               PIN code structure

             Maximum number of user codes is 250 with Network Module; without Network Module,
             maximum is 25 user codes.

              Set Up User PIN Codes
                User PIN Codes can only be programmed through the Master PIN Code*.
                1. Touch the screen with the back of your hand or fingers to activate    .
                2. Enter the 4-8 digit Master PIN code followed by the    key.
                   Lock Response: “Menu mode, enter number, press the        key to continue.”
                3. Enter “2” followed by the    key.
                4. Enter “1” followed by the    key.
                5. Enter the User Number to be registered (1-25) followed by the     key.
                6. Enter a 4-8 digit PIN code for the User number followed by the     key.
                7. To continue adding users press the     key.
                8. Press the     key to complete the process and conclude the programming session.
                    Note: When registering User codes, the code must be entered within 20 seconds or
                    time expires, Lock Response: “Time expired”, no codes are registered and the process
                    must be re-started.

               *Master PIN code must be registered before User codes can be added.


                Open Door with PIN Code

               1                                          2                          3
               Touch lock with                            Enter PIN code.            Press the    key
               back of hand or                                                       to confirm the
               fingers to activate.                                                  selection.




                                                                                                                               17
                                                                                                        P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                Feature Programming Through Menu Mode Using Master PIN code*

         1. Touch the screen with the back of your hand or fingers to activate                                             .
         2. Enter the 4-8 digit Master PIN code* followed by the                                    key.
             Lock Response: “Menu mode, enter number, press the                                         key to continue.”
         3. Enter digit corresponding to the function to be performed followed by the                                                     key.
             Follow the voice commands.
            *The Master PIN code must be registered prior to any other programming of the lock.


               1            2                   3                                                    User Number (UN)

                      M                                               M                               ƒƒ 1~25: without network module
                                          Master PIN Code Setting
                                                                                                      ƒƒ 1~250: with network module
                                         User PIN Code Registration       Register
                                                                                                                      U
                                                                                                                                             Continue


                                                                                                                                             Complete


                                                                          Delete                                               Continue


                                                                                                                               Complete



                                         Advanced Lock Settings              Auto Re-lock Setting                         Enable


                                                                                                                          Disable


                                                                              Inside Escutcheon LED                       Enable


                                                                                                                          Disable




                                                                            One Touch Locking Setting                     Enable


                                                                                                                          Disable




                                              Volume Setting                 High


                                                                             Low


                                                                            Silent


                                           Language Setting mode           English


                                                                           Spanish


                                                                           French



                                              Lockout Mode                  Enable


                                                                            Disable



                                           **Network Module Setting        Register                   Note: If the lock is connected to a network controller, it is
                                                                                                      recommended that it is programmed through the central-
                                       **This function appears                                        ized user interface (PC or hand-held device) to ensure
                                       only with RF network                 Delete                    communication between the lock and the controller unit.
                                       module installed.


                                                                                                                                                                      18
                                                                                                                                           P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                    MISCELLANEOUS
                 Hardware Troubleshooting.......................................................................................17
                 Programming Troubleshooting................................................................................18
                 Installing the Network Module . ..............................................................................19
                 Change Lever Handing .................................................................................... 20-21
                 Replace/Install Cylinder . ........................................................................................22
                 Sample Pin Code Management Sheets............................................................ 23-24

                                                          TROUBLESHOOTING

            Hardware Troubleshooting
        Cycle the lock in both the locked and the unlocked positions. If problems are found:

                            Symptom                                                            Suggested Action
        Door is binding                              a. Check that door and frame are properly aligned and door is free swinging.
                                                     b. Check hinges: They should not be loose or have excessive wear on knuckles.
        Latch will not deadlock                      a. Check for sufficient clearance of the latch within the strike-side jamb. Correct this by
                                                        increasing the depth of the pocket for the latch.
                                                     b. Check for misalignment of latch and/or strike which may be preventing latch from
                                                       properly entering the strike. With the door open, extend and retract the latch; if it is
                                                       smooth, check the strike alignment.


        Latch does not extend or retract smoothly    a. Latch and strike are misaligned, see above.
                                                     b. Check the backset of door relative to adjustments already made to latch.
                                                     c. Verify proper door preparation and re-bore holes that are too small or misaligned.
                                                     d. Verify keypad cable/connector is routed under the latch (see Fig. A).
                                                     e. Verify latch is installed with correct side up (Fig. A).



                                                                                 Inside of Door




                                                                                       Figure A




                                                                                                                                                         19
                                                                                                                                  P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


            Programming Troubleshooting

                        Symptom                                                                      Suggested Action
       Lock does not respond – door is open and      The touchscreen will become active when pressed with the back of hand or fingers in at least 3 areas
       accessible.                                   simultaneously.
                                                     Use a larger area of the hand or fingers and verify contact with at least 3 areas.
                                                     If touchscreen numbers are visible, check to see if they respond when pressed.
                                                     Check batteries are installed and oriented correctly in the battery case.
                                                     Check batteries are in good condition; replace batteries* if discharged.
                                                     Check to see if touchscreen cable is fully connected and not pinched.
       Lock does not respond – door is locked and    Mechanical key will grant access.
       inaccessible.
                                                     Batteries may be completely discharged.
                                                     Use mechanical key to gain entry and replace batteries*.
       The unit is on for a while, and then shows    The batteries do not have enough power. Replace the batteries*.
       no reaction. Lights dim.

       Unit chimes to indicate code acceptance,      Check to see if there is an existing lock device on the door.
       but the door will not open.
                                                     Check the door gaps for any foreign objects between door and frame.
                                                     Check that the cable is firmly connected to the PCB.
       Unit operates to allow access, but will not   Check to see if Passage Mode** is enabled (Network module units only).
       automatically re-lock.
                                                     If the Passage Mode icon on the touchscreen and the status indicator on the
                                                     interior escutcheon flicker for several seconds, it is set at Passage Mode.
                                                     Disable Passage Mode to lock the door.
                                                     If low battery indicator is lit, replace batteries*.
       PIN codes will not register.                  PIN codes must consist of 4 to 8 digits to register.
                                                     The same PIN code cannot be used for multiple users.
                                                     Registration/management of PIN codes is set by the authority of Master Code.
                                                     The Master PIN code must be registered prior to adding any users.
                                                     Contact the Master user.
                                                     User codes must be entered within 20 seconds (while the touchscreen is active) or the process will have
                                                     to be restarted.
                                                     The star       (*) or pound        (#) can not be used as part of the PIN code.

       Upon entering a PIN code and pressing the     Lockout Mode is enabled.
       star (*) key, the unit displays an “invalid
       code” error or the lock times out without     Only the Master Code can enable Lockout Mode.
       responding.
                                                     Contact the Master user.

       Upon entering a PIN code and pressing the     Check to see if lock is set** at Lockout Mode.
       (*) key, the red padlock icon appears and
       there are different tones.                    Setting/managing Lockout Mode is done through Master Code only. Contact the Master user.

       The unit operates, but it makes               Check to see if Silent Mode is enabled (pages 8, 11).
       no sound.

       The unit responds “Low Battery”               This is the voice alarm alerting that it is time to replace the batteries. Replace all four (4) batteries with
                                                     new AA Alkaline batteries*.

       Upon entering a PIN code and pressing         The digits entered were incorrect or incomplete. Re-enter the correct code.
       the star (*) key, the unit responds “Wrong
       number of digits.”

       * When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface; it is
         recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
       ** Network module units only




                                                                                                                                                                      20
                                                                                                                                             P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                 Installing the Network Module

                 IMPORTANT: The batteries must be removed prior to removing and/or inserting the
                 network module:

                            • Remove batteries

                            • Remove and/or insert network module

                            • Reinstall batteries




                   Use Feature Programming step 7 (page 16) for enrollment of the Network Module.




                                                                                                                  21
                                                                                           P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                   How to Change Handing of Lever (Reverse Levers)

                1. Remove the outside lever handle:
                      A. Insert key in cylinder (outside lever handle); rotate key 90° clockwise.
                      B. Insert allen wrench (included) in set screw on side of lever (toward edge of
                         door); turn clockwise to loosen.
                      C. Pull to remove lever handle/key/cylinder.




                                                  90°
                                    CCW




                                                             A
                                     B




                                                                                                    90°

                                                                                      F

                                                                                                                        C




                                                                                                                          22
                                                                                                    P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


              2. Remove the inside lever handle:

                       A. Insert allen wrench (included) in set screw on side of lever
                           (towards edge of door); turn clockwise to loosen lever handle.
                       B. Pull to remove lever handle.




                                                                                 B




                                   A



                3. Change the lever handing:
                       A. Remove and switch handles (inside to outside, outside to inside).
                       B. Remove cylinder from outside lever handle.
                       C. Insert cylinder in "new" outside lever (Fig. 3A).
                       D. Push handle in allowing holes for set screw to align.
                       E. Insert set screw and tighten by turning set screw counter-clockwise.




                                    Correct

                                                             Figure 3A




                                                                                         Figure 3B

                                                                 Incorrect


                                                    NOTE: "Swoop" of lever handle
                                                  must be oriented in upward direction
                                                          as shown in Fig. 3A




                                                                                                                            23
                                                                                                     P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                        How to Replace or Install Cylinder

                     1. Remove cylinder:
                        A. Repeat previous steps for removing the outside lever handle.
                        B. Remove cylinder.



                     2. Install new cylinder:
                            A. Insert cylinder in "new" outside lever.
                            B. Push handle in allowing holes for set screw to align.
                            C. Insert set screw and tighten by turning set screw counter-clockwise.
                            D. Verify that new cylinder fits and rotates freely.
                            E. Test operation of the new cylinder/key.`




                                                                                                                   24
                                                                                             P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                        PIN CODE MANAGEMENT SAMPLE SHEETS

                                           PIN Code Management (No Network Module - Up to 25 Users)
       Location:                          Door Number:                    User                User Name    User #    PIN Code

         User Type          User Name           User #     PIN Code

         Master                                                         User 13
         User 01                                                        User 14
         User 02                                                        User 15
         User 03                                                        User 16
         User 04                                                        User 17
         User 05                                                        User 18
         User 06                                                        User 19
         User 07                                                        User 20
         User 08                                                        User 21
         User 09                                                        User 22
         User 10                                                        User 23
         User 11                                                        User 24
         User 12                                                        User 25




                                                                                                                                 25
                                                                                                          P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                            PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries
         User Type          User Name               User #     PIN Code          User                  User Name                 User #   PIN Code

          Master                                                              User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
                                                                                                                                                     26
                                                                                                                              P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand


                                              ONLINE LITERATURE AND TEMPLATES

                                     For the latest information on Yale products visit our website at
                                     www.yalelocks.com. Click on the “Literature” button to find the
                                     most up-to-date catalogs, parts manuals, templates, specifica-
                                     tions and installation instructions.




                                                       Yale Locks & Hardware
                  100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
                               Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
      Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of
       Copyright © 2012, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express
                                  written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited.

       YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family
                                                               and personal belongings.

         ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
                                                                                                                           P/N AYRT-220-INST-FUL Rev A
An ASSA ABLOY Group brand



Document Created: 2012-02-14 10:05:12
Document Modified: 2012-02-14 10:05:12

© 2024 FCC.report