Manual - YRT210-ZB

FCC ID: U4A-YRHCPZB0

Users Manual

Download: PDF
FCCID_1641560

                          Certification Exhibit



                          FCC ID: U4A-YRHCPZB0
                           IC: 6982A-YRHCPZB0

                     FCC Rule Part: 15.247
           IC Radio Standards Specification: RSS-210

                      ACS Project Number: 12-0001

                Manufacturer: Assa Abloy Inc.
Models: YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB




                      Manual – YRT210-ZB




       5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                   Yale Real Living™ Push Button Lever
                                 Installation and Programming Instructions


                                                                             NOTE TO INSTALLER

                                                                             FAILURE TO FOLLOW THESE INSTRUCTIONS
                                                                             COULD RESULT IN DAMAGE TO THE PRODUCT
                                                                             AND VOID THE FACTORY WARRANTY




                                   For Technical Assistance call Yale at 1-800-810-WIRE (9473)

                 This document is available on our website in printed Spanish and French. Go to www.yalecommercial.com.
                            Click "Product Information & Documentation" and then "Installation Instructions".

               Este documento está disponible en español en nuestra página de internet. Vaya a www.yalecommercial.com.
                      Presione "Información del Producto y Documentación" y luego "Instrucciones de Instalación".

                Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalecommercial.com.
                     Cliquez sur le " ; Information sur le produit et Documentation" et puis " Installation Instructions".


                                                                                                           P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                          TABLE OF CONTENTS

            Warnings..........................................................................................................................2
                 Return Lock to Factory Default.................................................................................3
            Introduction......................................................................................................................3
            Installation
                 Components and Tools..............................................................................................4
                 Prepare Lock for Installation.................................................................................. 5-6
                 Install Lock........................................................................................................... 6-11
            Programming
                 Programming Features-Menus-Keys-Definitions.............................................. 12-13
                 Lock Operation.................................................................................................. 14-15
            Miscellaneous Information
                 Hardware Troubleshooting.......................................................................................17
                 Programming Troubleshooting................................................................................18
                 Installing the Network Module ...............................................................................19
                 Change Lever Handing .................................................................................... 20-21
                 Installing/Replacing Cylinder ................................................................................ 22
                 Sample Pin Code Management Sheets............................................................ 23-24

                                                                  WARNINGS
             Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc.
             could void the user's authority to operate the equipment.
            IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and
            security of this product. Misalignment can cause performance degradation and a lessening of
            security.
            Finish Care: This lockset is designed to provide the highest standard of product quality and perfor-
            mance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp
            cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coat-
            ing and result in tarnishing.

            FCC:
            FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)
            Model(s): YRT210-ZW, YRT210-ZB
            This equipment has been tested and found to comply with the limits for a Class B digital device,
            pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
            harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
            frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
            interference to radio communications. However, there is no guarantee that interference will not occur in a
            particular installation. If this equipment does cause harmful Interference to radio or television reception,
            which can be determined by turning the equipment off and on, the user is encouraged to try to correct
            the interference by one or more of the following measures:
                 • Reorient or relocate the receiving antenna.
                  •    Increase the separation between the equipment and receiver.
                  •    Connect the equipment into an outlet on a circuit different from that to which the receiver
                       is connected.
                  •    Consult the dealer or an experienced radio/TV technician for help.

                                                                                                                                                  2
                                                                                                                         P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


             To reset the lock to factory default, see the following:
                     Reset Lock to Factory Default
                                                                                              Reset Button
               The following procedure returns the lock to its factory defaults
               by deleting all user codes (including the Master PIN code*) and
               returning all programming features to their original default settings
               (see below).
               1. Remove the batteries and then remove the inside escutcheon
                  to access the reset button.
               2. The reset button (see image at right) is located above the
                  PCB cable connector.
               3. Hold down the reset button for a minimum of 3 seconds and
                  then reinstall the batteries; once the batteries are properly
                  installed, release the reset button.
               All features, including adjustable settings** (see below) should
               now be returned to factory default.
               Upon reset, Master Code Registration is the only option available
               and must be performed prior to any other programming of the lock.
               See "Operation" later in this manual for programming instructions.              Inside Escutcheon



                    Factory Default Settings
                                             Settings                    Factory Default

                                           Master Code                Registration required

                                           Auto Re-lock                     Enabled

                                        One Touch Re-Lock                   Enabled

                                               Audio                        Enabled

                                        Auto Re-lock Time                **30 Seconds

                                      Wrong Code Entry Limit               **5 Times

                                          Shutdown Time                  **60 Seconds

                                   **Adjustable only when using Network Module




                                                                                                                     3
                                                                                              P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


          Industry Canada:
          Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)
          Model(s): YRT210-ZW, YRT210-ZB

          This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment
          Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful
          interference, and (2) this device must accept any interference received, including interference that may
          cause undesired operation.

          Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne
          causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce
          dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle
          interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

          For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:
          “This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
          environment. This equipment should be installed and operated with minimum distance 20cm between
          the radiator and your body. This transmitter must not be co-located or operating in conjunction with any
          other antenna or transmitter.”

          Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate
          using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
          Canada. To reduce potential radio interference to other users, the antenna type and its gain should be
          so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
          successful communication.
          En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne
          d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour
          réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies
          de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
          pour une communication réussie.
          Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s).
          Operation is subject to the following two conditions: 1) this device may not cause interference, and 2)
          this device must accept any interference, including interference that may cause undesired operation of
          the device.
          Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
          fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des
          interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
          causer un mauvais fonctionnement du dispositif.

                                                   INTRODUCTION
      The Yale Real Living™ Stand-alone Push Button Lever Lock combines a robust lockset with a
      contemporary electronic aesthetic.
      Users benefit from an interactive Push Button keypad that makes day-to-day access effortless for
      simple updates to user information in the event of staffing changes or security breaches.
      Yale Real Living™ is engineered for quick and easy installation and fits in place of a standard lever
      lock door prep (ANSI/BHMA A156.115).
      If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network
      controller. That distance is influenced by objects between the lock and the controller and may be
      expanded depending on proximity to other RF network devices. Also, if the lock is connected to a
      network controller, it is recommended that it is programmed through the centralized user interface
      (PC or hand-held device) to ensure communication between the lock and the controller unit.
                                                                                                                            4
                                                                                                     P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                      INSTALLATION

                                                     COMPONENTS AND TOOLS

            Included in the box. . .
                 Installation Instructions                 Inside Mounting Plate                        Keys
                 Template                                  (with gasket)                                Cylinder
                 Latch Bolt                                Inside Escutcheon                            Battery Cover
                 Strike Plate                              Outside Escutcheon                           Allen Wrench
                                                           (2) Screw Packs (see below)                  4 AA Alkaline Batteries



            Parts Illustrations



                                                                                                                           4 AA Alkaline
                                                                                                                             Batteries
                                                                                                    Battery Cover


                                                 Latch Bolt


                              Outside                                                             Network Module
                                                                                                     (Optional)
                            Escutcheon                                      Inside                                          Latch bolt
                                                                          Escutcheon                                          Strike
                                            Allen Wrench                                         Keys
                                         (2) Hex Set Screws


                                                               (2) Inside Mounting Plate Screws                            Cylinder



     Inside Mounting Plate        Outside & Inside Lever
          with Gasket                    Handles                                                            (4) Inside Escutcheon
    (back of Inside Escutcheon)                                 (2) Latch & (2) Strike Plate Mounting         Mounting Screws
                                                                                Screws



              Tools Needed
            Door Prep                                                   Lock Installation
              ƒƒ 2-1/8" (54mm) hole saw                                   ƒƒ #2 Phillips screw driver
              ƒƒ 1" (26mm) boring bit                                     ƒƒ Allen wrench (3mm) - provided
              ƒƒ 7/64" (2.5mm) drill bit
              ƒƒ Chisel & hammer


                                                                                                                                           5
                                                                                                                    P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                    INSTALL LOCK


               Install Latch
              The lock is packed representative of how it will install on the door.
              Before installing the lock on the door:
        A. Remove the latch (Fig. 1) and strike plate from the packaging.
        NOTE: Latch ships with backset in 2-3/8" position (Fig. 1).
                   Backset is the measurement from door edge to center
                   of 2-1/8" diameter hole (see template supplied with lock).
        If required, pull to extend to 2-3/4" backset position (Detail 1A).
        NOTE: Different holes are used for (2) through bolts depending on backset (see Detail 1A).


                                                                                  2-3/8" through bolt posts




                                       Figure 1
                                                                                  2-3/4" through bolt posts



                                                                                          Detail 1A


        NOTE: Make sure door has been prepped according to specifications in template included
              with lock.
        NOTE: The latch bolt (and strike) can be installed in only one of two ways -
              with the bevel (slope) of latch facing out or facing in while standing
              outside of the door.
        If the door opens in, the bevel will face the outside; if the doors opens out, the
        bevel will face in.
        The strike plate is installed according to the orientation of the latch bolt. See
        Figures 1 & 2 for an example of a RH door that opens in.

        NOTE: Both latch face and strike plate have adhesive-backed covers to
              prevent marring and should be removed upon installation.

      B. Install latch bolt in door.
        1. Attach with two (2) M4 x 25.4mm screws supplied.
      C. Install strike on the door frame, using two (2) M4 x 25mm                          (4) M4 x 25.4mm      Figure 2
         screws supplied, making sure to allow for the latch to be                          Flat Head
                                                                                            Combination Screws
         centered in the strike.

                                                                                                                            6
                                                                                                   P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                            Install Outside Escutcheon

              NOTE: The "tops" of both the square drive tube and the hub (in the shank) are marked to
                    indicate their orientation for proper installation (Figures A & B).




                                              Outside Escutcheon                                  Outside of Door
                                                 (with gasket)

                             Do not remove clip from Outside Escutcheon shank until correct handing has
                             been determined and Outside Lever Handle is to be installed.
                             (See page 9)

               1. From outside of door, position the outside escutcheon by first routing the cable
                  through 2-1/8" diameter hole and under the latch (Fig. 3A & B), then insert
                  posts* and tailpiece into the latch.



                                                                     Inside of Door
                                                                                                      "Top" of Drive Tube
                                                                                                       (marked WHITE)




                                                                                      Figure 1B
                    Tailpiece
                                 Outside of Door                    NOTE: Cable goes
                                Figure 1A
                                                                   under latch (Fig. 1A & 1B).


                  *Posts are inserted in holes according to
                  backset adjustment. (Refer back to Detail 1A
                  under "Install Lock")




                                                                                                                                   7
                                                                                                            P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


        3. Install outside escutcheon.
            A. Position the outside escutcheon by routing the             Outside of Door
               cable through 2-1/8" diameter hole (Fig. 3A),                                      Square
                                                                                                Drive Tube
               under the latch.                                                                 is marked
                                                                                                (WHITE) to
                                                                                                 indicate
           NOTE: The "tops" of both the square drive tube and the                                  "top"
             tailpiece it contains are marked to indicate their
             proper orientation (Fig. 3A & 3B).
            B. Ensure tailpiece is oriented in the horizontal position
              (Fig. 3B) and insert tailpiece through center of latch
              so that outside escutcheon is flush to the surface of
              the door.                                                                Figure 3A




                        NOTE: Cable goes           Inside of Door
                        under latch (Fig. 3B).                            "Top" of Drive Tube
                                                                           (marked WHITE)

                            Tailpiece must be in
                             horizontal position
                            RED mark indicates
                                    "top"

                                                            Figure 3B




          4. Holding the outside escutcheon flush to the door,
             position the inside mounting plate by routing the
             cable/connector through the mounting plate's 1/2"
             rectangular hole below center hole and then route
             through left upper slot, then behind center rib (Fig. 4A).


          5. Secure both assemblies using (2) M4 x 25mm pan
             head machine screws (Fig. 4A).
               Ensure that outside escutcheon is vertically aligned.
               Tighten securely with a #2 Phillips screwdriver.
               Do not over-tighten.
                                                                                                 Figure 4A




                                                                                                                         8
                                                                                                  P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


       6. Attach cable assembly to the inside escutcheon printed circuit board (PCB) by lining up
          notches on top of cable connector to slots on PCB connector (Fig. 6A & 6B).
            Press connector in firmly using thumbs until completely seated (properly seated position
            indicated by arrows on PCB as in Fig. 6A and 6B).
                                    Route cable
                                   as indicated -
                                   do not cover
                                        holes




                                                                              Figure 6B




                                    Figure 6A

                      CAUTION:
                     Use care when assembling to ensure that the cable lies against the back recessed
                     area of the inside escutcheon (Fig. 6A).
                     Position and bend cable, as shown in Fig. 6A to prevent binding when installing the
                     escutcheon over the mounting plate.


         7. Install inside escutcheon:
             A. Ensure that thumb turn on inside escutcheon is positioned
                vertically (Fig. 7).
             B. Install and secure inside escutcheon to inside mounting plate
                using (4) M4 x 8mm [8-32 x 5/16"] pan head machine screws
                through the inside escutcheon into the mounting plate.


        NOTE: Make sure cable does not obstruct path of the mounting
              screws and is not being pinched by any metal parts.



                                                           Vertical




                                                                                                                    9
                                                                                             P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


               Determine Lever Handing

            Before proceeding with the next step, determine that the handing of the lever is correct.
             ƒƒ Both outside and inside lever handles should always point toward the door hinges.




            8. Attach outside lever handle to the outside escutcheon:

                A. Once correct handing is determined, remove the
                   clip from the shank (Fig. 8A) that has held the
                   hub in its correct position.
                Do not rotate cam from its original position.
                B. Install hex set screw




                                                                                       Figure 8A
                                                                                                            Detail 8A1


                  NOTE: For correct lever handing, the
                        hex set screw for the outside
                        lever shank must be installed
                        as shown (Fig. 8B).                                              Hex Set
                                                                                         Screw




                                                     Figure 8B
                                                                              RH/RHR               LH/LHR


               C. Install cylinder in outside lever as indicated (Fig. 8C).

                Note correct "swoop" of lever handle (Fig. 8C)



                            Correct

                                                 Figure 8C

                                                                                       Incorrect

                                                                                                                            10
                                                                                                      P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


              D. Insert key in cylinder (outside lever handle); rotate key 90° clockwise (Fig. 8E).
              E. Insert allen wrench (included) in set screw on side of shank (toward edge of
                 door); turn clockwise to allow placement of lever handle over shank; do not overtighten.
              F. Push lever handle/key/cylinder in until hole on handle aligns with set screw.




                                                                              Hinge side of Door
                                                         F
                                                                        90°



                                                                                            D


                                                     Figure 8E
                                          E



               G. Insert allen wrench and tighten set screw by turning counter-clockwise (Fig. 8F).
               H. Turn key 90° counter-clockwise; pull to remove key and test operation of lever
                  handle, ensuring that the latch moves smoothly.




                                                              90°




                                              G

                                                                    H
                                                  Figure 8F



                                                                                                                          11
                                                                                                   P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


             9. Attach inside lever handle:
                 A. Rotate thumbturn counter-clockwise to horizontal position (Fig. 9A).




                                               Figure 9A



                 B. Insert allen wrench (included) in set screw        C. Turn set screw counter-clockwise
                     on side of shank (toward edge of door);              to tighten.
                     turn clockwise to allow placement of
                     inside lever handle over shank.




                                                           Figure 9B
                                                                                Figure 9C



                 IMPORTANT: Before installing the batteries, test the mechanical operation of lock
                 by rotating the outside and inside lever handles. Also try using both the thumbturn and
                 key. The movement of the latch should be smooth and unobstructed.
                 If operation is not smooth, review the previous steps to ensure proper installation, while
                 maintaining proper alignment of escutcheons.

              10. Insert four (4) AA alkaline batteries; the lock
                  will flash and beep several times..


               11. Note: Refer to programming instructions prior to
                   completion of this step.
                    Install battery cover and tighten Phillips
                    head screw.




                                                                                                                    12
                                                                                              P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                                PROGRAMMING

                  Programming Features-Menus-Keys-Definitions.............................................. 12-13
                  Operation........................................................................................................... 14-15


                                 PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS


              Outside                                                                               Inside
                                                                           Hex Screw
                                                                                                                   Battery Cover
             Status Indicator                                                                                                                        Network Module Slot


                                                                Numbers

                                                                                                                                                         Alkaline Batteries
                                                                                                                                                         4 AA Type




             Cylinder




                Menu and Icons Used in This Guide

                  ~               Click the indicated number.                           M               Enter Master PIN code* (4-8 digits in length).


                                  Press the Star key on the keypad to Enter or          U               Enter User PIN. Can be 4-8 digits in length.
                                  Accept entry.
                                  Press the Pound key on the keypad to enter                            User Number (1 - 25);
                                  Menu mode.                                                            RF Controlled (1 - 250).

          *The Master Pin Code must be registered prior to any further programming of the lock.



               Status Indicators
                      1   Low Battery Warning                        2   Lockout Mode                               3   Return to previous step


                                                RED                                         RED &                                                 BLUE
                                                                                            BLUE




                                                                                                                                                                         13
                                                                                                                                           P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


             Definitions
              Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all
              user PIN code access. When attempting to enter a code while the unit is in Lockout, the
              Status Indicator flashes RED and BLUE; the keypad flashes as well.
              Low Battery: When battery power is low, the Status Indicator flashes RED. If battery
              power is completely lost, use the key override.
              Master PIN Code: The Master code is used for programming and for feature settings.
              NOTE: The Master Pin Code must be registered prior to programming the lock. The
              Master code will also operate the lock.
              Auto Re-Lock Time: After successful code entry and the unit unlocks, it will automati-
              cally re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5)
              to thirty (30) seconds.
              One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt
              (during Auto Re-Lock duration or when Auto Re-Lock is disabled).
              Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow
              operation after the wrong code entry limit has been met. When the unit is in Shutdown,
              the Status Indicator flashes RED and BLUE; the keypad flashes as well.
              Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone
              playback for use in quiet areas. Audio mode is enabled or disabled through feature pro-
              gramming by the Master code.
              Status LED: Located on inside escutcheon.
              User PIN Code: The User code operates the lock. Maximum number of user codes is
              250 with Network Module; without Network Module, maximum is 25 user codes.
              Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering
              a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is
              adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no
              RF network enabled - default is 5; 10 with RF network enabled).




                             Factory Default Settings

                                          Settings                   Factory Default

                                        Master Code                Registration required

                                        Auto Re-lock                     Enabled

                                     One Touch Re-Lock                   Enabled

                                           Audio                         Enabled

                                     Auto Re-lock Time                **30 Seconds

                                   Wrong Code Entry Limit               **5 Times

                                      Shutdown Time                   **60 Seconds

                                 *Adjustable with Network Module




                                                                                                                      14
                                                                                                P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                              OPERATION



            Register Master Code Before Programming*
             1. Press the        key to enter Master Code Registration.
             2. Enter a 4-8 digit Master PIN code followed by the                  key.


                            11                                       2
                             Press the  key to enter Master           Enter a 4-8 digit Master PIN code
                             Code Registration.
                                                                      followed by the     key.




             PIN code structure

          Maximum number of user codes is 250 with Network Module; without Network Module,
          maximum is 25 user codes.

            User Pin Code Registration
              User Codes can only be programmed through the Master Code*.
              1. Enter the 4-8 digit Master PIN code followed by the    key.
              2. Enter    followed by the     key.
              3. Enter the User number to be registered (1-25) followed by the                     key.
              4. Enter a 4-8 digit PIN code for the User number followed by the                     key.

                Note: When registering User codes, the code must be entered within 20 seconds.
                If time expires, no codes are registered and the process must be re-started.

              *Master PIN Code must be registered prior to programming the lock.




                                                                                                                                  15
                                                                                                           P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                  Feature Programming Through Menu Mode Using Master PIN code*

           1. Enter the 4-8 digit Master PIN code followed by the                        key.
           2. Enter digit corresponding to the function to be performed followed by the                                             key.
               Note: If the lock is connected to a network controller, it is recommended that it is
               programmed through the centralized user interface (PC or hand-held device) to
               ensure communication between the lock and the controller unit.
            *The Master PIN code must be registered prior to programming of the lock.


                                                                                              User Number (UN)
                1                    2
                                                                                                ƒƒ 1~25: without network module
                                                                                                ƒƒ 1~250: with network module
        M                   Master PIN Registration   M
                                                                                          U
                                                              Register                                       Complete
                             User PIN Registration


                                                              Delete
                                                                                          Complete




                                                             Advanced Lock Settings             Auto Re-lock Setting                        Enable


                                                                                                                                            Disable



                                                                                                 Inside Escutcheon LED                      Enable


                                                                                                                                            Disable



                                                                                               One Touch Locking Setting                   Enable


                                                                                                                                           Disable




                                                                   Audio Mode                 Enable

                                                                                                                       For quiet areas, select Disable (3)
                                                                                                                       in Audio Mode.


                                                                                              Disable



                                                                         N/A




                                                                All Code Lockout              Enable


                                                                                              Disable



                                                              **Network Module Setting        Register                 Note: If the lock is connected to a
                                                                                                                       network controller, it is recommended
                                                                                                                       that it is programmed through the
                                                          **This function appears                                      centralized user interface (PC or hand-
                                                                                              Delete
                                                          only with RF network                                         held device) to ensure communication
                                                          module installed.                                            between the lock and the controller unit.




                                                                                                                                                                   16
                                                                                                                                    P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                   Open Door with PIN Code

                        1                    2                         3
                        Enter PIN code.      Complete the code entry   Unlock.
                                             by pressing the  key.




                                                                                                        17
                                                                                 P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                                          MISCELLANEOUS
             Hardware Troubleshooting.......................................................................................17
             Programming Troubleshooting................................................................................18
             Installing the Network Module . ..............................................................................19
             Change Lever Handing .................................................................................... 20-21
             Replace/Install Cylinder . ........................................................................................22
             Sample Pin Code Management Sheets............................................................ 23-24



                                                               TROUBLESHOOTING


             Hardware Troubleshooting
        Cycle the lock in both the locked and the unlocked positions. If problems are found:

                            Symptom                                                                 Suggested Action
         Door is binding                                  a. Check that door and frame are properly aligned and door is free swinging.
                                                          b. Check hinges: They should not be loose or have excessive wear on knuckles.
         Latch bolt will not deadlock                     a. Check for sufficient clearance of the latch bolt within the strike-side jamb. Correct this by
                                                             increasing the depth of the pocket for the latch bolt.
                                                          b. Check for misalignment of latch bolt and/or strike which may be preventing latch bolt from
                                                            properly entering the strike. With the door open, extend and retract the latch bolt; if it is
                                                            smooth, check the strike alignment.


         Latch bolt does not extend or retract smoothly   a. Latch bolt and strike are misaligned, see above.
                                                          b. Check the backset of door relative to adjustments already made to latch bolt.
                                                          c. Verify proper door preparation and re-bore holes that are too small or misaligned.
                                                          d. Verify keypad cable/connector is routed under the latch bolt (see Fig. A).
                                                          e. Verify latch bolt is installed with correct side up (Fig. A).



                                                                                      Inside of Door




                                                                                            Figure A




                                                                                                                                                             18
                                                                                                                                       P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


           Programming Troubleshooting

                       Symptom                                                         Suggested Action
       Lock does not respond – door is           •   Press each keypad button to see if they respond when pressed.
       open and accessible.                      •   Check batteries are installed and oriented correctly (polarity) in the battery case.
                                                 •   Check batteries are in good condition; replace batteries* if discharged.
                                                 •   Check to see if cable is fully connected and not pinched.
       Lock does not respond – door is           •   Batteries may be completely discharged.
       locked and inaccessible.                      •    Use mechanical key to gain entry and replace batteries*.
       Unit chimes to indicate code accep-       •   Check to see if there is another locking device on the door.
       tance, but the door will not open.        •   Check the door gaps for any foreign objects between door and frame.
                                                 •   Check that the cable is firmly connected to the PC board.
       Unit operates to allow access, but will   •   Check to see if Auto Re-lock Mode is enabled.
       not automatically re-lock.                    •     Disable Auto Re-lock Mode to lock the door (automatically).
                                                 •   If low battery indicator is lit (see below), change batteries*.
       PIN codes will not register.              •   PIN codes must consist of 4 to 8 digits to register.
                                                 •   The same PIN code cannot be used for multiple users.
                                                 •   Registration/management of PIN codes is set by the authority of the Master Code.
                                                     •    Contact the Master user
                                                 •   User codes must be entered within 20 seconds or the process will have to be restarted.
                                                 •   The star     (*) or pound      (#) cannot be used as part of the PIN code.
       Upon entering a PIN code and press-       •   Lockout Mode is enabled.
       ing the star (*) key, the lock gives      •   Only the Master can enable/disable Lockout Mode.
       a series of beeps, flashes red and
       blue LEDs seven times, and does not           •    Contact the Master user.
       unlock.
       Upon entering a PIN code and press-       •   Check to see if the lock is set to Lockout Mode.
       ing the (*) key, there are different      •   Setting/managing Lockout Mode is done through Master Code only. Contact the Master
       tones.                                        user.

       The unit operates, but it makes           •   Enable Audio Mode.
       no sound.

       The unit displays intermittent RED        •   This is the Low Battery indicator alerting that it is time to replace the batteries. Replace
       flashes.                                      all four (4) batteries* with new AA Alkaline batteries.

       Upon entering a PIN code and press-       •   The digits entered were incorrect or incomplete. Re-enter the correct code followed by
       ing the star (*) key, the unit responds       the star     key.
       with a series of beeps and the keypad
       flashes three times.


      * When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface; it is
        recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
      ** Network module units only




                                                                                                                                                    19
                                                                                                                           P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                 Installing the Network Module

                 IMPORTANT: The batteries must be removed prior to removing and/or inserting the
                 network module:

                            • Remove batteries

                            • Remove and/or insert network module

                            • Reinstall batteries




                   Use Feature Programming step 7 (page 15) for enrollment of the
                   Network Module.




                                                                                                              20
                                                                                        P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


           How to Change Handing of Lever (Reverse Levers)

        1. Remove the outside lever handle:
             A. Insert key in cylinder (outside lever handle); rotate key 90° clockwise.
             B. Insert allen wrench (included) in set screw on side of lever (toward edge of
                door); turn clockwise to loosen lever handle.
             C. Pull to remove lever handle/key/cylinder.




                                          90°




                                                                                                  C

                                                    A
                              B
                                                                                                      90°




                                                                                                                      21
                                                                                               P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


              2. Remove the inside lever handle:

                       A. Insert allen wrench (included) in set screw on side of lever
                           (towards edge of door); turn clockwise to loosen handle.
                       B. Pull to remove lever handle.




                                                                                 B




                                   A



                3. Change the lever handing:
                       A. Remove and switch handles (inside to outside, outside to inside).
                       B. Remove cylinder from outside lever handle.
                       C. Insert cylinder in "new" outside lever (Fig. 3A).
                       D. Push handle in allowing holes for set screw to align.
                       E. Insert set screw and tighten lever handle by turning set screw
                       counter-clockwise.



                                    Correct

                                                             Figure 3A




                                                                                         Figure 3B

                                                                 Incorrect


                                                    NOTE: "Swoop" of lever handle
                                                  must be oriented in upward direction
                                                          as shown in Fig. 3A



                                                                                                                           22
                                                                                                     P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                 How to Replace or Install Cylinder

              1. Remove cylinder:
                 A. Repeat previous steps for removing the outside lever handle.
                 B. Remove cylinder.



              2. Install new cylinder:
                    A. Insert cylinder in "new" outside lever.
                    B. Push handle in allowing holes for set screw to align.
                    C. Insert set screw and tighten by turning set screw counter-clockwise.
                    D. Verify that new cylinder fits and rotates freely.
                    E. Test operation of the new cylinder/key.




                                                                                                                23
                                                                                         P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                        PIN CODE MANAGEMENT SAMPLE SHEETS

                                           PIN Code Management (No Network Module - Up to 25 Users)
       Location:                          Door Number:                    User                User Name    User #   PIN Code

         User Type          User Name           User #     PIN Code

         Master                                                         User 13
         User 01                                                        User 14
         User 02                                                        User 15
         User 03                                                        User 16
         User 04                                                        User 17
         User 05                                                        User 18
         User 06                                                        User 19
         User 07                                                        User 20
         User 08                                                        User 21
         User 09                                                        User 22
         User 10                                                        User 23
         User 11                                                        User 24
         User 12                                                        User 25




                                                                                                                                24
                                                                                                          P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                            PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries
         User Type          User Name               User #     PIN Code          User                  User Name              User #   PIN Code

          Master                                                              User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
                                                                                                                                                  25
                                                                                                                          P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand


                                              ONLINE LITERATURE AND TEMPLATES

                                     For the latest information on Yale products visit our website at
                                     www.yalelocks.com. Click on the “Literature” button to find the
                                     most up-to-date catalogs, parts manuals, templates, specifica-
                                     tions and installation instructions.




                                                       Yale Locks & Hardware
                  100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
                               Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
      Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of
       Copyright © 2012, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express
                                  written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited.

       YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family
                                                               and personal belongings.

         ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
                                                                                                                           P/N AYRT-210-INST-FUL Rev A
An ASSA ABLOY Group brand



Document Created: 2012-02-14 10:06:01
Document Modified: 2012-02-14 10:06:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC