User Manual

FCC ID: U4A-YRHCPZB0

Users Manual

Download: PDF
FCCID_1468402

                                  Yale Real Living™ Touchscreen Deadbolt
                                 Installation and Programming Instructions


                                                                              NOTE TO INSTALLER

                                                                              FAILURE TO FOLLOW THESE INSTRUCTIONS
                                                                              COULD RESULT IN DAMAGE TO THE PRODUCT
                                                                              AND VOID THE FACTORY WARRANTY




                                    For Technical Assistance call Yale at 1-800-810-WIRE (9473)

                  This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.
                            Click “Product Information & Documentation” and then “Installation Instructions”.

                 Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.
                       Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”.

                  Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com.
                      Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.


                                                                                                             P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                                          TABLE OF CONTENTS

            Warnings...................................................................................................................... 2-3
            Introduction......................................................................................................................3
            Installation
                 Components and Tools..............................................................................................4
                 Prepare Lock for Installation......................................................................................5
                 Install Lock............................................................................................................. 6-7
            Programming
                 Programming Features-Menu Keys-Definitions.................................................... 8-9
                 Operation........................................................................................................... 10-12
            Miscellaneous Information
                 Return Lock to Programming Defaults....................................................................13
                 Hardware Troubleshooting.......................................................................................13
                 Programming Troubleshooting................................................................................14
                 Replace/Install Cylinder...........................................................................................15
                 Sample Pin Code Management Sheets............................................................ 16-17

                                                                    WARNINGS
               Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc.
               could void the user's authority to operate the equipment.
              IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and
              security of this product. Misalignment can cause performance degradation and a lessening of
              security.
              Finish Care: This lockset is designed to provide the highest standard of product quality and
              performance. Care should be taken to ensure a long-lasting finish. When cleaning is required
              use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes
              could damage the coating and result in tarnishing.
              FCC:
              FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)
              Model(s): YRDZW, YRDZB
              This equipment has been tested and found to comply with the limits for a Class B digital
              device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
              protection against harmful interference in a residential installation. This equipment generates,
              uses, and can radiate radio frequency energy and, if not installed and used in accordance with
              the instructions, may cause harmful interference to radio communications. However, there is
              no guarantee that interference will not occur in a particular installation. If this equipment does
              cause harmful Interference to radio or television reception, which can be determined by turning
              the equipment off and on, the user is encouraged to try to correct the interference by one or
              more of the following measures:
                  • Reorient or relocate the receiving antenna.
                  • Increase the separation between the equipment and receiver.
                  • Connect the equipment into an outlet on a circuit different from that to which the
                      receiver is connected.
                  • Consult the dealer or an experienced radio/TV technician for help.

                                                                                                                                                  2
                                                                                                                         P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


            Industry Canada:
            Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)
            Model(s): YRDZW, YRDZB

            This Class B digital apparatus meets all requirements of the Canadian Interference Causing
            Equipment Regulations. Operation is subject to the following two conditions: (1) this device
            may not cause harmful interference, and (2) this device must accept any interference received,
            including interference that may cause undesired operation.

            Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence
            canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions
            suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif
            doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer
            l’opération peu désirée.

            “This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
            environment. This equipment should be installed and operated with minimum distance 20cm
            between the radiator and your body. This transmitter must not be co-located or operating in
            conjunction with any other antenna or transmitter.”

            Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only
            operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter
            by Industry Canada. To reduce potential radio interference to other users, the antenna type
            and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not
            more than that necessary for successful communication.
            En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec
            une antenne d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par
            Industrie Canada. Pour réduire le risque d'interférence aux autres utilisateurs, le type d'antenne
            et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente
            (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie.
            Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS
            standard(s). Operation is subject to the following two conditions: 1) this device may not cause
            interference, and 2) this device must accept any interference, including interference that may
            cause undesired operation of the device.
            Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
            fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des
            interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui
            peuvent causer un mauvais fonctionnement du dispositif.

                                                     INTRODUCTION

           The Yale Real Living™ Stand-alone Touchscreen Deadbolt Lock combines a robust lockset with a
           contemporary electronic aesthetic.
           Users benefit from an interactive touchscreen that makes day-to-day access effortless, as well as
           offering voice-guided programming for simple updates to user information in the event of staffing
           changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and
           fits in place of a standard deadbolt lock door prep (ANSI/BHMA A156.115).
           If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network
           controller. That distance is influenced by objects between the lock and the controller and may be
           expanded depending on proximity to other RF network devices. Also, if the lock is connected to a
           network controller, it is recommended that it is programmed through the centralized user interface
           (PC or hand-held device) to ensure communication between the lock and the controller unit.
                                                                                                                   3
                                                                                             P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                                    INSTALLATION

                                                    COMPONENTS AND TOOLS


            Included in the box. . .
                Quick Start Guide                    Inside Escutcheon                      Bolt
                Installation Instructions            Inside Mounting Plate                  Strike Plate
                Door Marker                          Battery Cover                          Screw Pack (see below)
                Outside Escutcheon                   4 AA Alkaline Batteries                Keys




            Parts Illustrations




                                                                                                              Bolt
                                                                                  Battery Cover




                                                               Inside
                    Outside              Inside               Mounting            4 AA Alkaline
                  Escutcheon           Escutcheon               Plate                                      Strike Plate
                                                                                    Batteries




                                  (3) Mounting                                                               (4) Screws
               (2) Through           screws
                   bolts                                        Keys



              Tools Needed
            Door Prep                                             Lock Installation
              ƒƒ 2-1/8" (54mm) hole saw                              ƒƒ #2 Phillips screwdriver
              ƒƒ 1" (26mm) boring bit
              ƒƒ 7/64" (2.5mm) drill bit
              ƒƒ Chisel & hammer



                                                                                                                            4
                                                                                                      P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                              PREPARE LOCK FOR INSTALLATION

                Unpack the Lock

           The lock is packed representative of how it will install
           on the door.
           Before installing the lock on the door:
           A. Inside escutcheon
                1. Loosen the screw (Phillips #2) holding the battery
                   cover. (The screw remains attached to battery                                                 Battery Cover
                   cover)
                                                                                                                       2
                2. Slide the battery cover up and out (note the two tabs
                   at bottom of battery cover).
                3. Remove the inside mounting plate (with gasket) from              Inside Escutcheon
                   the back (door side) of the inside escutcheon.                            1




                                                       a. Ensure that gasket
                                                          on inside mounting
                                                          plate is properly
                                                          fitted. Note the
                                                          positioning of the
                                                          gasket's five rubber
                                                          nubs (Figure 3A) .

             Inside Escutcheon & Mounting Plate
             (with gasket)
                                                                                                 Figure 3A
                            3



             B. Bolt
             Note: Bolt ships with backset in 2-3/4" posi-
             tion. If required, press small black button
             on underside of bolt and push to shorten to                         Figure 3B
             2-3/8" backset position.
                            Image (Fig. 3B) shows proper orientation
                            when installing the bolt.




              C. The outside escutcheon (with gasket) remains assembled.




                                                                                                  Outside Escutcheon


                                                                                                                                 5
                                                                                                        P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                                     INSTALL LOCK

                                                                                1
            1. Install bolt in door.
             NOTE: The bolt must be in a retracted (unlocked) position
             when installing the lockset.
                                                                               (2) M4 x 25.4mm
             Attach with two (2) M4 x 25.4mm [8-32 x 1"] screws supplied.             [8-32 x 1"]
                                                                                       Flat Head
                                                                             Combination Screws

                                                                                         2
            2. Install strike on the door frame, making sure to allow
               for the bolt to be centered in the strike.

                                                                             (2) M4 x 25.4mm
                                                                             [8-32 x 1"]
                                                                             Flat Head
                                                                             Combination Screws




            3. Install outside escutcheon.
                 As you position the outside escutcheon, route the
                 cable through 2-1/8" diameter hole (Figure 3A).
            NOTE: Cable must go under bolt and through (Fig. 3B).
             Ensure that the tailpiece is oriented correctly
             (see arrows Fig. 3B).



                                                                                    Figure 3A


            4. Holding the outside escutcheon flush to the door,
               position the inside mounting plate by first routing
               the cable and connector through the mounting
               plate's 1/2" hole (Fig. 4A) and then inserting the
               mounting plate “tongue” into the bottom slot of the
               outside escutcheon (Fig. 4B).
                                                                                             Figure 3B




                                                      “Tongue”
                            Figure 4A
                                                                 Figure 4B

                                                                                                                   6
                                                                                             P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


        5. Secure both assemblies using (2) M6 x 59.5mm pan
           head machine screws, making sure that outside
           escutcheon is vertically aligned.
            Tighten securely with a #2 Phillips screwdriver.
            Do not over-tighten.
        6. Attach cable assembly to the inside escutcheon
           printed circuit board (PCB) by lining up notches on
           top of cable connector to slots on PCB connector
           (Fig. 6B). Press connector in firmly using thumbs
           until completely seated (proper position indicated
           by arrows on PCB as in Figures 6A and 6B).
              CAUTION:
              Use care when assembling to ensure that
              the cable lies against the back recessed
              area of the inside escutcheon (Fig. 6A).                  Harness
                                                                          clip
              Position and bend cable, using the harness
              clip as shown in Fig. 6A to prevent binding
              when installing the escutcheon over the
              mounting plate.



                                                                     Figure 6A




                                Figure 6B


         7. Install inside escutcheon on inside mounting plate.
            Note in Fig. 7A the horizontal orientation of the tail   Figure 7A
            piece as you insert the inside escutcheon (thumb
            turn should be vertical).
         8. Install and secure using (3) M4 x 8mm [8-32 x 5/16"]
            pan head screws through the inside escutcheon into
            the mounting plate.
         IMPORTANT: Before installing the batteries, test
         the mechanical operation of the lock by using
         both thumb turn and the key. The movement of the
         bolt should be smooth and unobstructed. If
         operation is not smooth, review the previous steps
         to ensure proper installation.
         9. Insert four (4) AA alkaline batteries. Lock responds,
            “Welcome to Yale Real Living™” and will adjust for
            proper handing of the lock.
         Note: Refer to programming instructions prior to
         completion of step 10.
       10. Install battery cover and tighten Phillips head
           screw.
                                                                                                       7
                                                                                 P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                                      PROGRAMMING

                  Programming Features-Menus-Keys-Definitions.................................................. 8-9
                  Operation........................................................................................................... 10-12


                                PROGRAMMING FEATURES - MENU KEYS - DEFINITIONS


               Outside                                                               Inside


             Touchscreen                          “ P ” Key                                          Phillips Screw
                                                  (Return to Previous)
                                                                                                      Battery Cover

                                                                                                                       Network Module Slot

                                                  Numbers
             Low Battery                                                                                               Alkaline Batteries
               Indicator                                                                                               4 AA Type
                                                  Lockout Mode
                                                                                                                       Status Indicator
                                                  Cylinder
                                                                                    Thumb Turn


                                                                                                                       Privacy Mode Button




                                               Speaker Hole



                  Menu Keys and Icons Used in This Guide

                                    Touch the screen with back of hand or                        Repeat operation using settings indicated.
                                    fingers to begin and end actions.                            Enter Value 1 -10 (times or seconds).

                                    Press the indicated number.                     M            Enter Master PIN code (4-8 digits in
                            ~                                                                    length). Factory default: 12345678.
                                    Press the Star key on the touchscreen to         U           Enter User PIN code. Can be 4-8 digits
                                    Enter or Accept entry.                                       in length.
                                    Press the Pound key on the touchscreen                       User Number (1-25);
                                    to enter Menu mode.                                          RF Network-Controlled (1-250).
                                    Press this key to return to the previous
                                    step or menu setting.




                                                                                                                                               8
                                                                                                                       P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


             Status Indicators
                  1   Low Battery Warning                 2     Lock-out Mode                       3   Return to previous step




             Definitions
            All Code Lockout: This feature is enabled by the Master code. When enabled, it restricts all user PIN code access.
            When the unit is in Lockout Mode, the red locked padlock will appear on the screen when attempting to enter a code.
            Low Battery: When battery power is low, the low battery icon will begin blinking. If battery power is completely lost,
            use the key override.
            Master Code: The Master code is used for programming and for feature settings. NOTE: The default Master Pin
            Code must be changed prior to any further programming of the lock. The Master code will also operate the lock.
            Privacy Mode : This button located under the thumb turn on the inside escutcheon, activates/deactivates the voice
            response and keypad and is indicated by a blue LED flash every ten (10) seconds. It is also overridden by mechani-
            cally operating the thumb turn or key.
            Auto Re-lock: After successful code entry and the unit unlocks, it will automatically re-lock after a default of thirty
            (30) seconds. Re-lock time is adjustable from five (5) to thirty (30) seconds.
            OneTouch Re-Lock: When the bolt is retracted electronically, activating the keypad will extend the bolt (during
            Auto Re-Lock duration or when Auto Re-Lock is disabled).
            Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow operation after the wrong
            code entry limit has been met. When the unit is in Shutdown, the red locked padlock icon will flash every ten (10)
            seconds.
            Silent Mode: Enabling Silent mode shuts off the code confirmation tone playback for use in quiet areas. Silent mode
            is selected in the Volume feature (4) of Menu Mode. There are three levels (High/Low/Silent).
            Status LED: Located on inside escutcheon.
            User Code: The User code operates the lock. Maximum number of user codes is 250 with Network Module; without
            Network Module, maximum is 25 user codes.
            Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a valid PIN code the unit
            will shut down and not allow operation. Wrong code entry limit is adjustable from three (3) to ten (10) times through
            feature settings (up to 5 times with no RF network enabled - default is 5; 10 with RF network enabled).

               Factory Defaults
                             Settings                 Factory Defaults

                            Master Code                  12345678

                        Auto Re-lock                      Enabled

                              Volume                          High

                      Auto Re-lock Time                 *30 Seconds

                   Wrong Code Entry Limit                 *5 Times

                       Shutdown Time                    *60 Seconds

                             Language                     ENGLISH

               *Adjustable only when using Network Module                                                                                           9
                                                                                                                              P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                                              OPERATION

           Lock Activation

    The touchscreen can be activated in several ways:



        Touch lock with                              Touch lock with                           Press the       key to
        back of hand or                              fingers spread to                         activate.
        fingers to activate.                         activate.




           Lock Operation

           Change Default Master Code Before Programming*

           1. Touch the screen with the back of your hand or fingers to activate                           .
           2. Enter the 8-digit default Master PIN code (12345678) followed by the                             key.
                Lock Response: “Menu mode, enter number, press the                             key to continue.”
           3. Enter “1” followed by the                key.
           4. Enter new 4-8 digit Master PIN code followed by the                          key.

           *This step is required prior to any other programming of the lock.


          1
            Enter default Master PIN code,               Enter '1' to change Master PIN code       Enter the new Master PIN code (4~8
            followed by the   key.                       followed by the    key.                   digits), followed by the key.




                                                                                                                                           10
                                                                                                                      P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                PIN code structure

             Maximum number of user codes is 250 with Network Module; without Network Module,
             maximum is 25 user codes

               Set Up User Codes
                 User Codes can only be programmed through the Master PIN Code*.
                 1. Touch the screen with the back of your hand or fingers to activate    .
                 2. Enter the 4-8 digit Master PIN code followed by the    key.
                    Lock Response: “Menu mode, enter number, press the        key to continue.”
                 3. Enter “2” followed by the    key.
                 4. Enter “1” followed by the    key.
                 5. Enter the User Number to be registered (1-25) followed by the     key.
                 6. Enter a 4-8 digit PIN code for the User number followed by the     key.
                 7. To continue adding users press the     key.
                 8. Press the     key to complete the process and conclude the programming session.
                     Note: When registering User codes, the code must be entered within 20 seconds or
                     time expires, Lock Response: “Time expired”, no codes are registered and the process
                     must be re-started.

               *Master pin code must be changed from the default before User codes can be added.


                 Open Door with PIN Code

                1                                     2                                3
               Touch lock with                        Enter PIN code.                      Press the    key
               back of hand or                                                             to confirm the
               fingers to activate.                                                        selection.




                Privacy Mode vs. All Code Lockout Mode
                    ƒƒ Lockout is a Menu feature (6) that restricts Pin code access (except Master).
                    ƒƒ Privacy mode is set by pressing and holding the button (found below thumb turn) for a
                       duration of four beeps. This deactivates the keypad and sound, and because it is set from
                       the inside, provides a secure and silent lock for the convenience of the occupant(s).


                                                                                                                                         11
                                                                                                                   P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


             Feature Programming Through Menu Mode Using Master Code

               1. Touch the screen with the back of your hand or fingers to acitivate                            .
               2. Enter the 8-digit Master PIN code* followed by the                         key.
                   Lock Response: “Menu mode, enter number, press the                               key to continue.”
               3. Enter digit corresponding to the function to be performed followed by the                                     key.
                   Follow the voice commands.
                    Note: If the lock is connected to a network controller, it is recommended that
                    it is programmed through the centralized user interface (PC or hand-held device)
                    to ensure communication between the lock and the controller unit.
                     *The default Master pin code must be changed prior to programming of the lock.



                      1             2                    3                                      User Number (UN)

                            M                                                 M                     ƒƒ 1~25: without network module
                                                  Master PIN Code Setting
                                                                                                    ƒƒ 1~250: with network module
                                                 User PIN Code Registration       Register
                                                                                                             U
                                                                                                                                       Continue


                                                                                                                                       Complete


                                                                                  Delete                             Continue


                                                                                                                     Complete




                                                   Auto Re-lock Setting           Enable


                                                                                  Disable



                                                     Volume Setting                High


                                                                                    Low


                                                                                   Silent


                                                   Language Setting mode          English


                                                                                  Spanish


                                                                                  French



                                                     All Code Lockout             Enable


                                                                                  Disable



                                                   *HCP Module Setting            Register

                                              *This function appears only
                                              with RF network module              Delete
                                              installed.




                                                                                                                                                  12
                                                                                                                           P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                                       MISCELLANEOUS
             Return Lock to Programming Defaults....................................................................13
             Hardware Troubleshooting.......................................................................................13
             Programming Troubleshooting................................................................................14
             Replace/Install Cylinder . ........................................................................................15
             Sample Pin Code Management Sheets............................................................ 16-17




             Return Lock to Programming Defaults
                                                                                                                     Reset Button
         To return the lock to programming defaults:
         1. Disassemble the lock using pages 6 and 7.
         2. The reset button (see arrow) is located above the PCB cable                                                                        Cable
            connector.
         3. Hold down the reset button while reinstalling the batteries*.
         4. Reassemble the lock using pages 6 and 7.
             All programming should now be returned to factory defaults.
          *This procedure also clears the automatic handing for the
          Yale Real Living™ locks (see item 9, page 7).



                                                         TROUBLESHOOTING


             Hardware Troubleshooting
        Cycle the lock in both the locked and the unlocked positions. If problems are found:

            Symptom                                     Suggested Action
            Door is binding                             a. Check that door and frame are properly aligned and door is free swinging.
                                                        b. Check hinges: They should not be loose or have excessive wear on knuckles.

            Bolt will not deadlock                      a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing
                                                           the depth of the pocket for the bolt.
                                                        b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly
                                                           entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the
                                                           strike alignment.

            Bolt does not extend or retract smoothly    a. Bolt and strike are misaligned, see above.
                                                        b. Check the backset of door relative to adjustments already made to bolt.
                                                        c. Verify proper door preparation and re-bore holes that are too small or misaligned.




                                                                                                                                                                13
                                                                                                                                P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


             Programming Troubleshooting

         Symptom                                   Suggested Action
        Lock does not respond – door is open      The touchscreen will become active when pressed with the back of hand or fingers in at least
        and accessible.                           3 areas simultaneously.
                                                  Use a larger area of the hand or fingers and verify contact with at least 3 areas.
                                                  If touchscreen numbers are visible, check to see if they respond when pressed.
                                                  Check batteries are installed and oriented correctly in the battery case.
                                                  Check batteries are in good condition; replace batteries* if discharged.
                                                  Check to see if touchscreen cable is properly connected and not pinched.
        Lock does not respond – door is           Lock may be in Privacy mode (set from inside room). Mechanical key will grant access.
        locked and inaccessible.
                                                  Batteries may be completely discharged.
                                                  Use mechanical key to gain entry and replace batteries*.
        The unit is on for a while, and then      The batteries do not have enough power. Replace the batteries*.
        shows no reaction. Lights dim.

        Unit chimes to indicate code accep-       Check to see if there is an existing lock device on the door.
        tance, but the door will not open.
                                                  Check the door gaps for any foreign objects between door and frame.
                                                  Check that the cable is firmly connected to the PCB.
        Unit operates to allow access, but will   Check to see if Passage Mode** is enabled (Network module units only).
        not automatically re-lock.
                                                  If the Passage Mode icon on the touchscreen and the status indicator on the
                                                  interior escutcheon flicker for several seconds, it is set at Passage Mode.
                                                  Disable Passage Mode to lock the door.
                                                  If low battery indicator is lit, replace batteries*.
        PIN codes will not register.              PIN codes must consist of 4 to 8 digits to register.
                                                  The same PIN code cannot be used for multiple users.
                                                  Registration/management of PIN codes is set at the authority of Master.
                                                  Contact the Master user.
                                                  User codes must be entered within 20 seconds (while the touchscreen is active) or the
                                                  process will have to be restarted.
                                                  The star      (*) or pound       (#) can not be used as part of the PIN code.
        Upon entering a PIN code and press-       Lockout Mode is enabled.
        ing the star (*) key, the unit displays
        an “invalid code” error or the lock       Only the Master can enable Lockout Mode.
        times out without responding.
                                                  Contact the Master user.
        Upon entering a PIN code and press-       Check to see if either you or your group** is set at Lockout Mode.
        ing the (*) key, the red padlock icon
        appears and there are different tones.    Setting/managing Lockout Mode is up to Master. Contact the Master user.

        The unit operates, but it makes           Check to see if Silent Mode is enabled (pages 8, 11).
        no sound.
        The unit responds “Low Battery”           This is the voice alarm alerting that it is time to replace the batteries. Replace all four (4)
                                                  batteries with new AA Alkaline batteries*.

        Upon entering a PIN code and press-       The digits entered were incorrect or incomplete. Re-enter the correct code.
        ing the star (*) key, the unit responds
        “Wrong number of digits.”

        * When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface (UI); it is
          recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).

        ** Network module units only




                                                                                                                                                    14
                                                                                                                               P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


            How to Replace or Install Cylinder

         1. Remove cylinder:                                                                                              A
              A. Remove outside escutcheon from door.
                                                                                                  B
              B. Remove rubber gasket.
              C. Remove two screws holding plastic guide
                 in place.
              D. Remove plastic guide.
              E. Remove screw with washer holding cylinder in
                 place (visible after plastic guide is removed).
                                                                                                                              E
              F. Remove cylinder by pulling towards the
                 door side of escutcheon.
                                                                                                                              F
              G. Remove cylinder ring from cylinder.
              Note position of ring flange in relation to cylinder.


                            Flange                                                                                    G
                     G




                D




                                                 C


             2. Slide new cylinder into sleeve.


                                                     2-5/8" (66.5) For 6 pin cylinders, 1-3/8" thick doors
                                                     2-7/8" (73) For 6 pin cylinders, 1-3/4" thick doors ONLY
                                                     1-3/16" (30) For 6 pin cylinders, 1-3/8" thick doors
                                                     1-7/16" (36.5) For 6 pin cylinders, 1-3/4" thick doors ONLY




           CAUTION: The cylinders furnished for use in 1-3/8" doors have a tailpiece that is 1/4" shorter
           than the standard cylinders that are furnished for 1-3/4" doors. Trying to install a standard
           cylinder in 1-3/8" will DAMAGE the lock body.
                                                                                                                                      15
                                                                                                                P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                        PIN CODE MANAGEMENT SAMPLE SHEETS

                                           PIN Code Management (No Network Module - Up to 25 Users)
       Location:                          Door Number:                    User                User Name   User #    PIN Code

         User Type          User Name           User #     PIN Code

         Master                                                         User 13
         User 01                                                        User 14
         User 02                                                        User 15
         User 03                                                        User 16
         User 04                                                        User 17
         User 05                                                        User 18
         User 06                                                        User 19
         User 07                                                        User 20
         User 08                                                        User 21
         User 09                                                        User 22
         User 10                                                        User 23
         User 11                                                        User 24
         User 12                                                        User 25




                                                                                                                               16
                                                                                                          P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                            PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries
         User Type          User Name               User #     PIN Code          User                  User Name              User #   PIN Code

          Master                                                              User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___

         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
         User ___                                                             User ___
                                                                                                                                                  17
                                                                                                                          P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand


                                              ONLINE LITERATURE AND TEMPLATES

                                     For the latest information on Yale products visit our website at
                                     www.yalelocks.com. Click on the “Literature” button to find the
                                     most up-to-date catalogs, parts manuals, templates, specifica-
                                     tions and installation instructions.
                                     Look for the     symbol and click on it to register for an
                                     ebusiness account.




                                                       Yale Locks & Hardware
                  100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
                               Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
      Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of
       Copyright © 2011, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express
                                  written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited.

       YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family
                                                               and personal belongings.

         ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
                                                                                                                            P/N AYRD220-INST-FUL Rev B
An ASSA ABLOY Group brand



Document Created: 2011-05-04 16:12:55
Document Modified: 2011-05-04 16:12:55

© 2024 FCC.report