ES1024-4 Final Report for FCC 15.247 and RSS-247 rev 1.pdf

FCC ID: U4A-SCYMCA1

Test Report

Download: PDF
FCCID_4198668

                                                                                                                Test Report
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS



                 Report No               ES1024-4

                        Client           ASSA ABLOY Inc.


                    Address              110 Sargent Drive
                                         New Haven, CT 06511


                       Phone             203-498-5686

             Items tested                Aperio V3 iN100
                 FCC ID                  U4A-SCYMCA1
                       IC                6982A-SCYMCA1
                     FRN                 0016550824

   Equipment Type                        Digital Transmission System
   Equipment Code                        DTS
Emission Designator                      2M77D1D

   FCC/IC Rule Parts                     CFR Title 47 FCC Part 15.247, ISED Canada RSS-247 Issue 2

                Test Dates               1/7/2019 to 1/10/2019

                     Results             As detailed within this report



             Prepared by
                                             Arik Zwirner – Sr. EMC Engineer


           Authorized by
                                             Yunus Faziloglu – Sr. EMC Engineer

                Issue Date                   2/25/2019


  Conditions of Issue                    This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’
                                         section on page 20 of this report.



Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under
Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation.
                           ____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                                                         page 1 of 21


                          Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
               ______________________________________________________________________



Contents

 Contents .................................................................................................................................. 2
 Summary and Test Methodology ............................................................................................. 3
 Product Tested - Configuration Documentation ....................................................................... 4
 Modifications Required for Compliance ................................................................................... 4
 Test Results ............................................................................................................................ 5
   Radiated Spurious Emissions .............................................................................................. 5
   AC Line Conducted Emissions ........................................................................................... 15
 Measurement Uncertainty...................................................................................................... 19
 Conditions Of Testing ............................................................................................................ 20


                                                                                                                  Form Final Report REV 12-07-15




                       ____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                           page 2 of 21


                       Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
            ______________________________________________________________________



Summary and Test Methodology

This test report supports an application for Class 2 Permissive Change for a transmitter
operating pursuant to:
CFR Title 47 FCC Part 15.247, ISED Canada RSS-247 Issue 2
EUT is the Aperio V3 iN100. It operates in the 2405MHz to 2475MHz frequency range.
All testing was performed according to the following rules/procedures/documents;
CFR Title 47 FCC Part 15.247, ISED Canada RSS-247 Issue 2, ISED Canada RSS-Gen Issue
5, FCC KDB 558074 D01 15.247 Measurement Guidance v05 and ANSI C63.10-2013.

Radiated Emissions were maximized by rotating the device around its installation axes as well
as varying the test antenna’s height and polarity. EUT antenna is internal and cannot be
maximized separately.

The EUT operating voltage is 9VDC from battery. Fresh batteries were used during testing.
The environmental conditions during each test are detailed in the results tables for each section.
Following bandwidths were used during radiated spurious and line conducted emissions testing.

         Frequency                                       RBW                                         VBW
       150kHz-30MHz                                      9kHz                                        30kHz
        30MHz-1GHz                                      120kHz                                       1MHz
          1-25GHz                                        1MHz                                        3MHz

EUT was tested for radiated spurious emissions and AC line conducted emissions and met the
corresponding requirements. Test sample was received in good condition.




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828       page 3 of 21


                               Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                    ______________________________________________________________________



Product Tested - Configuration Documentation
                                                                             EUT Configuration
           Work Order:          S1024
             Company:           Assa Abloy
       Company Address:         110 Sargent Drive
                                New Haven, CT 06511

                  Contact:      Steve Morse

                                                  MN                                                PN                                           SN
                  EUT:                iN100 (with New BT Module)                                   iN100                                          1
        EUT Description:        Aperio V3
     EUT Max Frequency:         2475 MHz
     EUT Min Frequency:         0.032 MHz

Support Equipment                                              MN                                                                   SN
AC/DC Brick                                              SYS1308-2424-W2                                                          SW-241PR
Laptop computer                                                dell
Sargent 12V Supply                                            3521                                                                 Sample 1
Sargent 24V Supply                                            3520                                                                 Sample 1

    Port Label           Port Type       # ports     # populated       cable type       shielded        ferrites   length (m)     in/out   under           comment
                                                                                                                                            test
DC Power input          Power DC        1            1               Power DC          No             No           10            in        yes        *not used for
                                                                                                                                                      emissions.
                                                                                                                                                      emissions done
                                                                                                                                                      with battery power
USB setup port          USB             1            1               USB               Yes            No           1             in        yes        *used to setup the
                                                                                                                                                      radio power and
                                                                                                                                                      channels

Software Operating Mode Description:
Commands are given to the EUT over USB, setting up the radio parameters. Then the laptop and usb are disconnected and the EUT continues operating in that mode until
battery power is removed.



                                                                              Clock Frequencies
            frequencies (MHz)      2475, 48, 32, 27.12, 18, 16, 13.56, 8, 0.125, 0.1, 0.032768, 0.03216, 0.032




Modifications Required for Compliance
None.




                             _____________________________________________________________
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                 One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                         page 4 of 21


                       Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
            ______________________________________________________________________



Test Results

Radiated Spurious Emissions
LIMITS
Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
comply with the radiated emission limits specified in Section 15.209(a).
[15.247(d)]

For the 2nd harmonic of the transmitter, duty-cycle correction factor was used to compute
average values from peak values.

Worst Case 100ms duty-cycle is 13.75% (calculated from trace data via software)
DCCF = 20*log(13.75/100) = -17.2dB




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 5 of 21


                               Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                    ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                           Work Order - S1024
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - Battery
Top Peaks Horizontal 30-1000MHz                                    Test Site - CH-1
Operator: AKZ                                                      Conditions - 23°C; 21%RH; 1023mBar
Notes:
ZigBee Channel 11



Data Taken at 11:35:42 AM, Monday, January 07, 2019
                                    Adjusted    Lim1:                            Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_1    Lim1    Lim1 Test     Margin   Cispr_Class    Lim2    Lim2 Test     Margin   Antenna     EUT
Frequency   Reading     Factor     Amplitude 09_Class_B   Margin    Results       Lim1         _B       Margin    Results       Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 30.412       32        -7.7         24.2       40         -15.8     PASS                    40.5       -16.3      PASS        -16.3     150        135
 162.284     35.4       -15.9        19.5       43.5       -24.1     PASS                    40.5        -21       PASS                  250         45
 946.189     32.3       -1.9         30.4       46         -15.6     PASS        -15.6       47.5       -17.1      PASS                  200        270


Curtis Straus - a Bureau Veritas Company                           Work Order - S1024
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - Battery
Top Peaks Vertical 30-1000MHz                                      Test Site - CH-1
Operator: AKZ                                                      Conditions - 23°C; 21%RH; 1023mBar
Notes:
ZigBee Channel 11



Data Taken at 11:35:42 AM, Monday, January 07, 2019
                                    Adjusted    Lim1:                            Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_1    Lim1    Lim1 Test     Margin   Cispr_Class    Lim2    Lim2 Test     Margin   Antenna   Turntable
Frequency   Reading     Factor     Amplitude 09_Class_B   Margin    Results       Lim1         _B       Margin    Results       Lim2     Height    Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 30.388      33.2       -7.7         25.5       40         -14.5     PASS        -14.5       40.5        -15       PASS         -15      100        315
 162.211     39.9       -15.9        23.9       43.5       -19.6     PASS                    40.5       -16.6      PASS                  100        225
 165.267     38.7       -16.1        22.6       43.5       -20.9     PASS                    40.5       -17.9      PASS                  150        225
 440.067     34.2       -10.2         24        46         -22       PASS                    47.5       -23.5      PASS                  100        180
 920.46      32.3       -2.1         30.2       46         -15.8     PASS                    47.5       -17.3      PASS                  100        270
 985.111     31.8       -1.3         30.5       54         -23.5     PASS                    47.5        -17       PASS                  200        225
                                                          30-1000MHz Low channel




                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                       page 6 of 21


                               Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                    ______________________________________________________________________



Curtis Straus - a Bureau Veritas Company                           Work Order - S1024
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - Battery
Top Peaks Horizontal 30-1000MHz                                    Test Site - CH-1
Operator: AKZ                                                      Conditions - 23°C; 21%RH; 1023mBar
Notes:
ZigBee Channel 18



Data Taken at 02:45:20 PM, Monday, January 07, 2019
                                    Adjusted    Lim1:                            Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_1    Lim1    Lim1 Test     Margin   Cispr_Class    Lim2    Lim2 Test     Margin   Antenna     EUT
Frequency   Reading     Factor     Amplitude 09_Class_B   Margin    Results       Lim1         _B       Margin    Results       Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 30.267      32.4       -7.6         24.8       40         -15.2     PASS        -15.2       40.5       -15.7      PASS        -15.7     150         90
 127.194     32.9       -14.2        18.7       43.5       -24.8     PASS                    40.5       -21.8      PASS                  250         0
 959.721      32        -1.9         30.1       46         -16       PASS                    47.5       -17.4      PASS                  250        270


Curtis Straus - a Bureau Veritas Company                           Work Order - S1024
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - Battery
Top Peaks Vertical 30-1000MHz                                      Test Site - CH-1
Operator: AKZ                                                      Conditions - 23°C; 21%RH; 1023mBar
Notes:
ZigBee Channel 18



Data Taken at 02:45:19 PM, Monday, January 07, 2019
                                    Adjusted    Lim1:                            Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_1    Lim1    Lim1 Test     Margin   Cispr_Class    Lim2    Lim2 Test     Margin   Antenna   Turntable
Frequency   Reading     Factor     Amplitude 09_Class_B   Margin    Results       Lim1         _B       Margin    Results       Lim2     Height    Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 30.703      32.8        -8          24.8        40        -15.2      PASS       -15.2       40.5       -15.7       PASS       -15.7     100        180
 162.09       39        -15.9        23.1       43.5       -20.5      PASS                   40.5       -17.4       PASS                 150        225
 165.315     39.8       -16.1        23.7       43.5       -19.9      PASS                   40.5       -16.8       PASS                 100        225
 554.431     33.6       -8.2         25.3        46        -20.7      PASS                   47.5       -22.2       PASS                 200        315
 695.371     33.7       -5.9         27.8        46        -18.2      PASS                   47.5       -19.7       PASS                 150        180
 927.371     32.4        -2          30.4        46        -15.7      PASS                   47.5       -17.1       PASS                 200        315
                                                         30-1000MHz Middle channel




                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                       page 7 of 21


                               Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                    ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                            Work Order - S1024
Radiated Emissions Electric Field 3m Distance                       EUT Power Input - Battery
Top Peaks Horizontal 30-1000MHz                                     Test Site - CH-1
Operator: AKZ                                                       Conditions - 23°C; 21%RH; 1023mBar
Notes:
ZigBee Channel 25



Data Taken at 03:38:21 PM, Monday, January 07, 2019
                                    Adjusted    Lim1:                             Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_1     Lim1    Lim1 Test     Margin   Cispr_Class    Lim2    Lim2 Test     Margin   Antenna     EUT
Frequency   Reading     Factor     Amplitude 09_Class_B    Margin    Results       Lim1         _B       Margin    Results       Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)      (dB)    (Pass/Fail)    (dB)    (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 30.461      32.4       -7.8         24.6        40        -15.4      PASS        -15.4       40.5       -15.9      PASS        -15.9     250        225
 133.548     33.4       -14.4        18.9       43.5       -24.6      PASS                    40.5       -21.6      PASS                  250         0
 162.308     36.4       -15.9        20.5       43.5        -23       PASS                    40.5        -20       PASS                  200         45
 921.115     31.9       -2.1         29.8        46        -16.2      PASS                    47.5       -17.7      PASS                  200        135
 972.112     32.2       -1.7         30.5        54        -23.4      PASS                    47.5        -17       PASS                  150        270
Curtis Straus - a Bureau Veritas Company                            Work Order - S1024
Radiated Emissions Electric Field 3m Distance                       EUT Power Input - Battery
Top Peaks Vertical 30-1000MHz                                       Test Site - CH-1
Operator: AKZ                                                       Conditions - 23°C; 21%RH; 1023mBar
Notes:
ZigBee Channel 25



Data Taken at 03:38:21 PM, Monday, January 07, 2019
                                    Adjusted    Lim1:                             Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_1    Lim1     Lim1 Test     Margin   Cispr_Class    Lim2    Lim2 Test     Margin   Antenna   Turntable
Frequency   Reading     Factor     Amplitude 09_Class_B   Margin     Results       Lim1         _B       Margin    Results       Lim2     Height    Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)      (dB)    (Pass/Fail)    (dB)    (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 30.703      33.1        -8          25.1       40         -14.9      PASS        -14.9       40.5       -15.4      PASS        -15.4     150        315
 162.041     39.8       -15.9        23.9       43.5       -19.6      PASS                    40.5       -16.6      PASS                  100        225
 165.267     40.7       -16.1        24.6       43.5       -18.9      PASS                    40.5       -15.9      PASS                  150        225
 168.249     38.8       -16.3        22.5       43.5        -21       PASS                    40.5        -18       PASS                  100        225
 778.84       33        -4.2         28.7       46         -17.3      PASS                    47.5       -18.8      PASS                  100         0
 947.523     32.1       -1.9         30.2       46         -15.8      PASS                    47.5       -17.3      PASS                  100        180
                                                          30-1000MHz High channel




                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                        page 8 of 21


                                  Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                       ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                                Work Order - S1024
Radiated Emissions Electric Field 3m Distance                           EUT Power Input - Battery
1-6GHz Horizontal Data                                                  Test Site - CH-1
Operator: AKZ                                                           Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 11, BLE Channel 19                                       DCCF: -17.2dB


Data Taken at 11:20:17 AM, Wednesday, January 09, 2019
                                         Adjusted   Pk Lim:                                                                                   Adjusted   Av Lim:
            Raw Peak     Correction        Peak   FCC_pt15_2              Peak               Peak        Worst Peak                             Avg    FCC_pt15_2                                            A nt e nna
Frequency    Reading       Factor       Amplitude  09_Peak               Margin             Results       Margin              DCCF           Amplitude 09_Average Avg Margin Avg Results                      H e i ght     EU T A z i m ut h

  (MHz)       (dBµV)      (dB/m)        (dBµV/m)       (dBµV/m)              (dB)          (Pass/Fail)         (dB)           (dB)           (dBµV/m)       (dBµV/m)            (dB)        (Pass/Fail)        ( c m)        ( de gr e e s)


  4810         57.7        -1.3            56.3               74             -17.7            PASS           -17.7            -17.2            39.1               54            -14.9          PASS             220                53


Curtis Straus - a Bureau Veritas Company                                            Work Order - S1024
Radiated Emissions Electric Field 3m Distance                                       EUT Power Input - Battery
1-6GHz Vertical Data                                                                Test Site - CH-1
Operator: AKZ                                                                       Conditions - 24°C; 21%RH; 1001mBar
Notes:                                                                              0
ZigBee Channel 11, BLE Channel 19                                                   0



Data Taken at 11:20:17 AM, Wednesday, January 09, 2019
                                                    Adjusted   Pk Lim:                                                       Adjusted   Av Lim:
            Raw Peak    Raw Avg       Correction     Peak    FCC_pt15_2               Peak            Peak       Worst Peak    Avg    FCC_pt15_2                        Worst Avg                              A nt e nna
Frequency    Reading    Reading         Factor     Amplitude  09_Peak                Margin          Results      Margin    Amplitude 09_Average Avg Margin Avg Results  Margin                                 H e i ght    EU T A z i m ut h

  (MHz)      (dBµV)     (dBµV)         (dB/m)        (dBµV/m)      (dBµV/m)            (dB)       (Pass/Fail)         (dB)       (dBµV/m)        (dBµV/m)              (dB)     (Pass/Fail)          (dB)        ( c m)       ( de gr e e s)


 2122.4       44.5       35.4            -5            39.4             74            -34.6           PASS                            30.4            54           -23.6             PASS                         275               71


  4810        50.5       47.8           -1.3           49.2             74            -24.8           PASS            -24.8           46.5            54               -7.5          PASS            -7.5         125              327


 5481.3       42.2       32.7            1.1           43.3             74            -30.7           PASS                            33.8            54           -20.2             PASS                         105              230



                                                                                     1-6GHz Low Channel

Curtis Straus - a Bureau Veritas Company                                Work Order - S1024
Radiated Emissions Electric Field 3m Distance                           EUT Power Input - Battery
1-6GHz Horizontal Data                                                  Test Site - CH-1
Operator: AKZ                                                           Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 18, BLE Channel 19                                       DCCF: -17.2dB


Data Taken at 01:16:05 PM, Wednesday, January 09, 2019
                                         Adjusted   Pk Lim:                                                                                   Adjusted   Av Lim:
            Raw Peak     Correction        Peak   FCC_pt15_2              Peak               Peak        Worst Peak                             Avg    FCC_pt15_2                                            A nt e nna
Frequency    Reading       Factor       Amplitude  09_Peak               Margin             Results       Margin              DCCF           Amplitude 09_Average Avg Margin Avg Results                      H e i ght     EU T A z i m ut h


  (MHz)       (dBµV)      (dB/m)        (dBµV/m)       (dBµV/m)              (dB)          (Pass/Fail)         (dB)           (dB)           (dBµV/m)       (dBµV/m)            (dB)        (Pass/Fail)        ( c m)        ( de gr e e s)


 4880.1        59.4        -0.7            58.8               74             -15.2            PASS           -15.2            -17.2            41.6               54            -12.4          Pass             225                48


Curtis Straus - a Bureau Veritas Company                                                        Work Order - S1024
Radiated Emissions Electric Field 3m Distance                                                   EUT Power Input - Battery
Top Peaks Vertical 1-6GHz                                                                       Test Site - CH-1
Operator: AKZ                                                                                   Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 18, BLE Channel 19



Data Taken at 01:16:05 PM, Wednesday, January 09, 2019
                                            Adjusted   Pk Lim:                          Peak Limit   Av Lim:  Margin to                                                   Average     Average
             Raw Peak     Correction         Peak    FCC_pt15_2 Margin to Peak Limit      Worst    FCC_pt15_2 Average                                                    Limit Test Limit Worst             Antenna           EUT
Frequency     Reading       Factor         Amplitude  09_Peak   Peak Limit Test Results   Margin 09_Average    Limit                                                       Result     Margin                 Height         Azimuth
  (MHz)        (dBµV)       (dB/m)         (dBµV/m)           (dBµV/m)              (dB)        (Pass/Fail)            (dB)          (dBµV/m)              (dB)          (Pass/Fail)          (dB)           (cm)           (degrees)
 2131.25        47.8            -5              42.8               74               -31.2            PASS                               54                 -11.2              PASS                           300                 47
   4880         48.2         -0.7               47.6               74               -26.4            PASS                               54                 -6.4               PASS                           100                 47
 5762.75        47.2            0.9             48                 74                -26             PASS              -26              54                  -6                PASS            -6             200                146
                                                                                      1-6GHz Mid Channel


                                 _____________________________________________________________
                     Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                     One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                                                           page 9 of 21


                                  Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                       ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                     Work Order - S1024
Radiated Emissions Electric Field 3m Distance                EUT Power Input - Battery
1-6GHz Horizontal Data                                       Test Site - CH-1
Operator: AKZ                                                Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 25, BLE Channel 19                            DCCF: -17.2dB


Data Taken at 01:46:25 PM, Wednesday, January 09, 2019
                                       Adjusted   Pk Lim:                                                                Adjusted   Av Lim:
            Raw Peak    Correction       Peak   FCC_pt15_2     Peak            Peak        Worst Peak                      Avg    FCC_pt15_2                                A nt e nna
Frequency    Reading      Factor      Amplitude  09_Peak      Margin          Results       Margin           DCCF       Amplitude 09_Average Avg Margin Avg Results          H e i ght   EU T A z i m ut h

  (MHz)      (dBµV)      (dB/m)       (dBµV/m)   (dBµV/m)      (dB)          (Pass/Fail)      (dB)           (dB)       (dBµV/m)    (dBµV/m)         (dB)    (Pass/Fail)      ( c m)      ( de gr e e s)


 4950.1       58.2        -0.3          57.9       74          -16.1           PASS          -16.1           -17.2         40.7           54         -13.3     Pass             211             18


Curtis Straus - a Bureau Veritas Company                                          Work Order - S1024
Radiated Emissions Electric Field 3m Distance                                     EUT Power Input - Battery
Top Peaks Vertical 1-6GHz                                                         Test Site - CH-1
Operator: AKZ                                                                     Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 25, BLE Channel 19



Data Taken at 01:46:25 PM, Wednesday, January 09, 2019
                                         Adjusted   Pk Lim:                          Peak Limit   Av Lim:  Margin to                            Average     Average
            Raw Peak     Correction       Peak    FCC_pt15_2 Margin to Peak Limit      Worst    FCC_pt15_2 Average                             Limit Test Limit Worst      Antenna         EUT
Frequency    Reading       Factor       Amplitude  09_Peak   Peak Limit Test Results   Margin 09_Average    Limit                                Result     Margin          Height       Azimuth
  (MHz)       (dBµV)       (dB/m)       (dBµV/m)    (dBµV/m)          (dB)        (Pass/Fail)        (dB)           (dBµV/m)       (dB)        (Pass/Fail)   (dB)           (cm)         (degrees)
 2107.25       47.5         -5.2          42.3          74            -31.7           PASS                            54           -11.7         PASS                       100             315
 2883.38       47.8         -3.2          44.6          74            -29.4           PASS                            54           -9.4          PASS                       200             315
 3972.88       45.7         -1.3          44.4          74            -29.6           PASS                            54           -9.6          PASS                       300             218
 4949.88       50.1         -0.3          49.8          74            -24.2           PASS           -24.2            54           -4.2          PASS        -4.2           100             315
 5413.13       45.5          1.1          46.6          74            -27.4           PASS                            54           -7.4          PASS                       200             146
                                                                       1-6GHz High Channel




                              _____________________________________________________________
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                 One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                            page 10 of 21


                                  Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                       ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                              Work Order - S1024
Radiated Emissions Electric Field 1m Distance                         EUT Power Input - Battery
Top Peaks Horizontal 6-18GHz                                          Test Site - CH-1
Operator: AKZ                                                         Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 11, BLE Channel 19



Data Taken at 03:34:07 PM, Wednesday, January 09, 2019
                                      Adjusted   Pk Lim:                          Peak Limit   Av Lim:                                       Avg Limit
            Raw Peak    Correction      Peak   FCC_pt15_2 Margin to Peak Limit      Worst    FCC_pt15_2             Margin to Avg Limit       Worst      Antenna     EUT
Frequency    Reading      Factor     Amplitude  09_Peak   Peak Limit Test Results  Margin 09_Average       DCCF     Avg Limit Test Results    Margin      Height   Azimuth
  (MHz)      (dBµV)      (dB/m)      (dBµV/m)   (dBµV/m)      (dB)    (Pass/Fail)   (dB)     (dBµV/m)     -17.2dB     (dB)     (Pass/Fail)     (dB)       (cm)     (degrees)
  7215        60.1         5.1         65.1       83.5       -18.4       PASS       -18.4      63.5       -17.2      -15.6        PASS                    200         22
 7320.3       53.5          5          58.5       83.5        -25        PASS                  63.5                    -5         PASS                    200        292
 9620.1       54.3         6.8         61.1       83.5       -22.4       PASS                  63.5                   -2.4        PASS         -2.4       200         71
 12024.9      50.7         9.4         60.1       83.5       -23.4       PASS                  63.5                   -3.4        PASS                    200         47
 14007.9      45.3        13.8         59.1       83.5       -24.4       PASS                  63.5                   -4.4        PASS                    100         97
Curtis Straus - a Bureau Veritas Company                              Work Order - S1024
Radiated Emissions Electric Field 1m Distance                         EUT Power Input - Battery
Top Peaks Vertical 6-18GHz                                            Test Site - CH-1
Operator: AKZ                                                         Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 11, BLE Channel 19



Data Taken at 03:34:07 PM, Wednesday, January 09, 2019
                                      Adjusted   Pk Lim:                          Peak Limit   Av Lim:                                       Avg Limit
            Raw Peak    Correction      Peak   FCC_pt15_2 Margin to Peak Limit      Worst    FCC_pt15_2             Margin to Avg Limit       Worst      Antenna     EUT
Frequency    Reading      Factor     Amplitude  09_Peak   Peak Limit Test Results  Margin 09_Average       DCCF     Avg Limit Test Results    Margin      Height   Azimuth
  (MHz)      (dBµV)      (dB/m)      (dBµV/m)   (dBµV/m)      (dB)    (Pass/Fail)   (dB)     (dBµV/m)     -17.2dB     (dB)     (Pass/Fail)     (dB)       (cm)     (degrees)
  7215        62.3         5.1         67.3       83.5       -16.2       PASS       -16.2      63.5       -17.2      -13.4        PASS                    175         0
 7320.3       51.8          5          56.9       83.5       -26.6       PASS                  63.5                   -6.6        PASS                    200         23
 9620.1       53.9         6.8         60.7       83.5       -22.8       PASS                  63.5                   -2.8        PASS         -2.8       150         47
 14376.3      46.9         13          59.9       83.5       -23.6       PASS                  63.5                   -3.6        PASS                    150        195

                                                                     6-18GHz Low Channel




                                _____________________________________________________________
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                 One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                      page 11 of 21


                                  Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                       ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                              Work Order - S1024
Radiated Emissions Electric Field 1m Distance                         EUT Power Input - Battery
Top Peaks Horizontal 6-18GHz                                          Test Site - CH-1
Operator: AKZ                                                         Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 18, BLE Channel 19



Data Taken at 04:34:34 PM, Wednesday, January 09, 2019
                                      Adjusted   Pk Lim:                          Peak Limit   Av Lim:                                       Avg Limit
            Raw Peak    Correction      Peak   FCC_pt15_2 Margin to Peak Limit      Worst    FCC_pt15_2             Margin to Avg Limit       Worst      Antenna     EUT
Frequency    Reading      Factor     Amplitude  09_Peak   Peak Limit Test Results  Margin 09_Average       DCCF     Avg Limit Test Results    Margin      Height   Azimuth
  (MHz)      (dBµV)      (dB/m)      (dBµV/m)   (dBµV/m)      (dB)    (Pass/Fail)   (dB)     (dBµV/m)     -17.2dB     (dB)     (Pass/Fail)     (dB)       (cm)     (degrees)
  7320        62.1          5          67.1       83.5       -16.4       PASS       -16.4      63.5       -17.2      -13.6        PASS                    200        300
 9760.2       54.5         7.3         61.7       83.5       -21.8       PASS                  63.5                   -1.8        PASS         -1.8       200         55
 13971.3      46.4        13.5         59.8       83.5       -23.7       PASS                  63.5                   -3.7        PASS                    125         74
Curtis Straus - a Bureau Veritas Company                              Work Order - S1024
Radiated Emissions Electric Field 1m Distance                         EUT Power Input - Battery
Top Peaks Vertical 6-18GHz                                            Test Site - CH-1
Operator: AKZ                                                         Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 18, BLE Channel 19



Data Taken at 04:34:34 PM, Wednesday, January 09, 2019
                                      Adjusted   Pk Lim:                          Peak Limit   Av Lim:                                       Avg Limit
            Raw Peak    Correction      Peak   FCC_pt15_2 Margin to Peak Limit      Worst    FCC_pt15_2             Margin to Avg Limit       Worst      Antenna     EUT
Frequency    Reading      Factor     Amplitude  09_Peak   Peak Limit Test Results  Margin 09_Average       DCCF     Avg Limit Test Results    Margin      Height   Azimuth
  (MHz)      (dBµV)      (dB/m)      (dBµV/m)   (dBµV/m)      (dB)    (Pass/Fail)   (dB)     (dBµV/m)     -17.2dB     (dB)     (Pass/Fail)     (dB)       (cm)     (degrees)
  7320        64            5           69        83.5       -14.5       PASS       -14.5      63.5       -17.2      -11.7        PASS                    175         0
 9760.2       52.1         7.3         59.4       83.5       -24.1       PASS                  63.5                   -4.1        PASS                    175         72
 14257.8      46.3        13.1         59.4       83.5       -24.1       PASS                  63.5                   -4.1        PASS         -4.1       150        145

                                                                     6-18GHz Mid Channel




                                _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                    page 12 of 21


                                      Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                           ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                                                  Work Order - S1024
Radiated Emissions Electric Field 1m Distance                                             EUT Power Input - Battery
6-18GHz Horizontal Data                                                                   Test Site - CH-1
Operator: AKZ                                                                             Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 25, BLE Channel 19



Data Taken at 09:59:41 AM, Thursday, January 10, 2019
                                                            Adjusted   Pk Lim:                                              Adjusted   Av Lim:
                Raw Peak     Raw Avg         Correction      Peak    FCC_pt15_2             Peak      Peak Test Worst Peak    Avg    FCC_pt15_2                                       Avg Test      Worst Avg       Antenna            EUT
Frequency        Reading     Reading           Factor      Amplitude  09_Peak              Margin      Results   Margin    Amplitude 09_Average Avg Margin                             Results       Margin          Height          Azimuth
  (MHz)          (dBµV)      (dBµV)           (dB/m)       (dBµV/m)          (dBµV/m)       (dB)      (Pass/Fail)      (dB)          (dBµV/m)     (dBµV/m)                (dB)       (Pass/Fail)        (dB)           (cm)         (degrees)
  7425            58.3         56.9             5.6            63.9            83.5         -19.6       PASS          -19.6            62.5              63.5             -1            PASS             -1            199              18
 17868.7          42.9         34.2            19.8            62.7            83.5         -20.8       PASS                           54                63.5             -9.5          PASS                           100              333
Curtis Straus - a Bureau Veritas Company                                                  Work Order - S1024
Radiated Emissions Electric Field 1m Distance                                             EUT Power Input - Battery
6-18GHz Vertical Data                                                                     Test Site - CH-1
Operator: AKZ                                                                             Conditions - 24°C; 21%RH; 1001mBar
Notes:
ZigBee Channel 25, BLE Channel 19



Data Taken at 09:59:41 AM, Thursday, January 10, 2019
                                                            Adjusted   Pk Lim:                                                  Adjusted   Av Lim:
                Raw Peak     Raw Avg         Correction      Peak    FCC_pt15_2             Peak        Peak        Worst Peak    Avg    FCC_pt15_2                        Worst Avg                                Antenna            EUT
Frequency        Reading     Reading           Factor      Amplitude  09_Peak              Margin      Results       Margin    Amplitude 09_Average Avg Margin Avg Results  Margin                                   Height          Azimuth
  (MHz)          (dBµV)      (dBµV)           (dB/m)       (dBµV/m)          (dBµV/m)       (dB)      (Pass/Fail)      (dB)          (dBµV/m)     (dBµV/m)                (dB)       (Pass/Fail)        (dB)           (cm)         (degrees)
  7425            42.8         32.7             5.6            48.4            83.5         -35.1       PASS                           38.3              63.5         -25.2             PASS                           200              218
 17852.1          43.7         34.3            19.9            63.6            83.5         -19.9       PASS          -19.9            54.2              63.5             -9.3          PASS            -9.3           200              340

                                                                                          6-18GHz High Channel

Radiated Emissions Table                                                                                                                                        CSsoft Radiated Emissions Calculator                       v 1.017.211
          Date: 10-Jan-19                                      Company: Assa Abloy                                                                                                                             Work Order: S1024
   Engineer: AKZ                                                                                                                                                                 EUT Operating Voltage/Frequency: Battery
       Temp: 24°C                                               Humidity: 21%                                                 Pressure: 991mbar
                                      Frequency Range: 18-25GHz                                                                                                                  Measurement Distance: 0.1 m
        Notes: ZigBee Channels 11, 18, & 25. BLE Channel 19

                                                                                                                                              FCC Class B High Frequency -                          FCC Class B High Frequency -
   Antenna                            Peak        Average        Pream p        Antenna      Cable      Adjusted          Adjusted                       Peak                                                 Average
 Polarization      Frequency      Reading          Reading        Factor         Factor      Factor   Peak Reading      Avg Reading             Lim it            Margin            Result          Lim it        Margin             Result
    (H / V)          (MHz)        (dBµV)              (dBµV)          (dB)       (dB/m)       (dB)       (dBµV/m)         (dBµV/m)            (dBµV/m)             (dB)           (Pass/Fail)      (dBµV/m)         (dB)           (Pass/Fail)
                                                                    ---      ---      ---                   ---                ---               ---               ---         ---        ---                       ---                ---
NO EMISSIONS WITHIN 20dB OF THE LIMIT.                              ---      ---      ---                   ---                ---               ---               ---         ---        ---                       ---                ---
                                                                    ---      ---      ---                   ---                ---               ---               ---         ---        ---                       ---                ---
    Test Site: EMI Chamber 1                                     Cable 1: Asset #2324                                                                             Cable 2: ---                                    Cable 3: ---
    Analyzer: Gold                                               Preamp: 18-26.5GHz                                                                              Antenna: 18-26.5GHz Horn                      Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.211                                                                                                                                                               Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor

                                                                                          18-25GHz All Channels




                                      _____________________________________________________________
                         Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                         One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                                                              page 13 of 21


                                   Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                        ______________________________________________________________________

Rev. 1/5/2019
Spectrum Analyzers / Receivers /Preselectors                         Range             MN                Mfr                  SN         Asset Cat Calibration Due Calibrated on
                2093 MXE EMI Receiver                           20Hz-26.5GHz N9038A                    Agilent         MY51210181 2093                 I            11/21/2019          11/21/2018
_
              Radiated Emissions Sites                             FCC Code         IC Code         VCCI Code              Range         Asset Cat Calibration Due Calibrated on
                      EMI Chamber 1                                  719150         2762A-6            A-0015           30-1000MHz 1685                I             12/7/2020           12/7/2018
                      EMI Chamber 1                                  719150         2762A-6            A-0015             1-18GHz            1685      I             12/7/2020           12/7/2018
_
         Meteorological Meters/Chambers                                                MN                Mfr                  SN         Asset Cat Calibration Due Calibrated on
            Weather Clock (Pressure Only)                                            BA928 Oregon Scientific              C3166-1            831       I             5/15/2020           5/15/2018
                         TH A#2082                                                    HTC-1             HDE                                  2082      II            3/23/2019           3/23/2018
_
                           Cables                                    Range                               Mfr                                          Cat Calibration Due Calibrated on
                       Asset #2456                               9KHz-18GHz                         MegaPhase                                          II           10/31/2019          10/31/2018
                       Asset #2464                               9KHz-18GHz                         MegaPhase                                          II           10/31/2019          10/31/2018
                       Asset #2480                               9KHz-18GHz                         MegaPhase                                          II           10/29/2019          10/29/2018
                         2489(6dB)                               9KHz-18GHz                                                                            II           11/27/2019          11/27/2018
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.



Rev. 2/5/2019
      Spectrum Analyzers / Receivers /Preselectors                   Range              MN             Mfr             SN              Asset        Cat           Calibration Due       Calibrated on
                   2093 MXE EMI Receiver                        20Hz-26.5GHz          N9038A         Agilent     MY51210181            2093          I              11/21/2019           11/21/2018
_
                 Radiated Emissions Sites                         FCC Code           IC Code      VCCI Code          Range             Asset        Cat           Calibration Due       Calibrated on
                        EMI Chamber 1                                719150          2762A-6         A-0015       30-1000MHz           1685          I               12/7/2020            12/7/2018
                        EMI Chamber 1                                719150          2762A-6         A-0015         1-18GHz            1685          I               12/7/2020            12/7/2018
_
         Preamps /Couplers Attenuators / Filters                     Range              MN             Mfr             SN              Asset        Cat           Calibration Due       Calibrated on
                      8449B HF Preamp                               1-18GHz           8449B          Agilent        1149055                          II             11/26/2019           11/26/2018
                          2116 BRF                             0.009-18000MHz BRM50702 Micro-Tronics                  G226             2116          II              11/8/2019            11/8/2018
_
                          Antennas                                   Range              MN             Mfr             SN              Asset        Cat           Calibration Due       Calibrated on
                         Orange Horn                                1-18GHz            3115          EMCO          0004-6123            390          I               11/6/2020            11/6/2018
_
            Meteorological Meters/Chambers                                              MN             Mfr             SN              Asset        Cat           Calibration Due       Calibrated on
                          TH A#2077                                                    HTC-1           HDE                             2077          II              3/23/2019            3/23/2018
                          TH A#2082                                                    HTC-1           HDE                             2082          II              3/23/2019            3/23/2018
_
                            Cables                                   Range                             Mfr                                          Cat           Calibration Due       Calibrated on
                         Asset #2464                             9KHz-18GHz                       MegaPhase                                          II             10/31/2019           10/31/2018
                         Asset #2465                             9KHz-18GHz                       MegaPhase                                          II             10/31/2019           10/31/2018
                         Asset #2480                             9KHz-18GHz                       MegaPhase                                          II             10/29/2019           10/29/2018
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.



Rev. 2/5/2019
      Spectrum Analyzers / Receivers /Preselectors                   Range                    MN                     Mfr             SN       Asset        Cat      Calibration Due      Calibrated on
                             Gold                              100Hz-26.5 GHz               E4407B                 Agilent      MY45113816    1284          I          3/19/2019           3/19/2018
_
                 Radiated Emissions Sites                         FCC Code                 IC Code               VCCI Code         Range      Asset        Cat      Calibration Due      Calibrated on
                        EMI Chamber 1                                719150                2762A-6                 A-0015       30-1000MHz    1685          I          12/7/2020           12/7/2018
                        EMI Chamber 1                                719150                2762A-6                 A-0015         1-18GHz     1685          I          12/7/2020           12/7/2018
_
         Preamps /Couplers Attenuators / Filters                     Range                    MN                     Mfr             SN       Asset        Cat      Calibration Due      Calibrated on
                          HF (Yellow)                             18-26.5GHz       AFS4-18002650-60-8P-4             CS            467559     1266          II        10/24/2019          10/24/2018
_
                          Antennas                                   Range                    MN                     Mfr             SN       Asset        Cat      Calibration Due      Calibrated on
                       HF (White) Horn                            18-26.5GHz              801-WLM                  Waveline          758       758          III     Verify before Use     date of test
_
            Meteorological Meters/Chambers                                                    MN                     Mfr             SN       Asset        Cat      Calibration Due      Calibrated on
               Weather Clock (Pressure Only)                                                BA928             Oregon Scientific   C3166-1      831          I          5/15/2020           5/15/2018
                          TH A#2082                                                          HTC-1                  HDE                       2082          II         3/23/2019           3/23/2018
_
                            Cables                                   Range                                           Mfr                                   Cat      Calibration Due      Calibrated on
                         Asset #2324                               1-26.5GHz           TM26-S1S1-120            MEGAPHASE 17139101 001        2324          II          8/9/2019           8/9/2018
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                 _____________________________________________________________
                    Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                             page 14 of 21


                       Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
            ______________________________________________________________________



AC Line Conducted Emissions
LIMITS

            Frequency of    Quasi-peak limit      Average limit
           emission (MHz)        (dBµV)             (dBµV)
                   0.15-0.5     66 to 56*          56 to 46*
                      0.5-5         56                 46
                       5-30         60                 50
         *Decreases with the logarithm of the frequency.
[47 CFR 15.207(a)]




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 15 of 21


                           Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                ______________________________________________________________________


MEASUREMENTS / RESULTS

Curtis Straus - a Bureau Veritas Company                                           Work Order # - S1024
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 120VAC/ 60Hz
Peak Detector Data                                                                 Test Site - CEMI-3
Notes:                                                                             Conditions: - 19.4°C; 35%RH; 1003mBar
EUT Line tested: 120VAC/60Hz; Neutral (line 0)                                     Test Engineer - Patrick Crozier
                                                                                   Witnessed by - Steve Morse



Data Taken at 05:03:45 PM, Friday, January 11, 2019

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.15              36              20.7            56.7             66.0             -9.3            PASS
    0.167            33.8             20.8            54.6             65.1            -10.5            PASS
    0.213            29.9             20.8            50.7             63.1            -12.4            PASS
    0.251            32.8             20.8            53.5             61.7             -8.2            PASS             -8.2
    0.315            26.6             20.8            47.3             59.8            -12.5            PASS
    0.51             20.1             20.8            40.8             56.0            -15.2            PASS


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S1024
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 120VAC/ 60Hz
Quick Average Detector Data                                                        Test Site - CEMI-3
Notes:                                                                             Conditions: - 19.4°C; 35%RH; 1003mBar
EUT Line tested: 120VAC/60Hz; Neutral (line 0)                                     Test Engineer - Patrick Crozier
                                                                                   Witnessed by - Steve Morse



Data Taken at 05:03:45 PM, Friday, January 11, 2019

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.155            26.2             20.7            46.9             55.7             -8.8            PASS
    0.251            22.9             20.8            43.6             51.7             -8.1            PASS             -8.1
    0.312            20.5             20.8            41.2             49.9             -8.7            PASS
    0.337            18.5             20.8            39.2             49.3            -10.1            PASS
    0.505            12.3             20.8            33.1             46.0            -12.9            PASS
    0.582            12.2             20.8            32.9             46.0            -13.1            PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 16 of 21


                           Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                ______________________________________________________________________



Curtis Straus - a Bureau Veritas Company                                           Work Order # - S1024
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 120VAC/ 60Hz
Peak Detector Data                                                                 Test Site - CEMI-3
Notes:                                                                             Conditions: - 19.4°C; 35%RH; 1003mBar
EUT Line tested: 120VAC/60Hz; Phase (line 1)                                       Test Engineer - Patrick Crozier
                                                                                   Witnessed by - Steve Morse



Data Taken at 04:43:22 PM, Friday, January 11, 2019

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.153             37              20.7            57.8             65.8             -8.0            PASS             -8.0
    0.184            31.5             20.8            52.2             64.3            -12.1            PASS
    0.25             28.5             20.7            49.3             61.8            -12.5            PASS
    0.332            24.7             20.7            45.4             59.4            -14.0            PASS
    0.508            19.2             20.8             40              56.0            -16.0            PASS
    0.617             19              20.8            39.7             56.0            -16.3            PASS


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S1024
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 120VAC/ 60Hz
Quick Average Detector Data                                                        Test Site - CEMI-3
Notes:                                                                             Conditions: - 19.4°C; 35%RH; 1003mBar
EUT Line tested: 120VAC/60Hz; Phase (line 1)                                       Test Engineer - Patrick Crozier
                                                                                   Witnessed by - Steve Morse



Data Taken at 04:43:22 PM, Friday, January 11, 2019

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.15             26.7             20.7            47.4             56.0             -8.6            PASS
    0.253            23.4             20.7            44.1             51.7             -7.6            PASS             -7.6
    0.306             21              20.7            41.8             50.1             -8.3            PASS
    0.513            12.3             20.8             33              46.0            -13.0            PASS
    0.546            11.9             20.8            32.7             46.0            -13.3            PASS
    0.602            11.4             20.8            32.1             46.0            -13.9            PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 17 of 21


                                  Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                       ______________________________________________________________________

Rev. 1/5/2019
     Spectrum Analyzers / Receivers /Preselectors                   Range               MN                 Mfr              SN       Asset   Cat   Calibration Due   Calibrated on
             Rental MXE EMI Receiver(1168255)                    20Hz-8.4GHz         N9038A              Agilent        MY53290009 1168255    I       8/23/2019        8/23/2018
_
                LISNs/Measurement Probes                            Range               MN                 Mfr              SN       Asset   Cat   Calibration Due   Calibrated on
                      LISN Asset 2092                            9KHz-30MHz         NNLK 8121         Schwarzbeck       NNLK 8121-662 2092    I       7/31/2019        7/31/2018
_
           Conducted Test Sites (Mains / Telco)                   FCC Code                             VCCI Code                             Cat   Calibration Due   Calibrated on
                           CEMI 3                                   719150                               A-0015                              III         NA              N/A
_
            Meteorological Meters/Chambers                                              MN                 Mfr              SN       Asset   Cat   Calibration Due   Calibrated on
                Weather Clock (Pressure Only)                                         BA928         Oregon Scientific     C3166-1     831     I       5/15/2020        5/15/2018
                         TH A#2077                                                    HTC-1               HDE                         2077    II      3/23/2019        3/23/2018
_
                           Cables                                   Range                                  Mfr                               Cat   Calibration Due   Calibrated on
                          CEMI-18                                9kHz - 2GHz                               C-S                                II      11/5/2019        11/5/2018
_
                         Attenuators                                Range               MN                 Mfr              SN       Asset   Cat   Calibration Due   Calibrated on
                     20dB Attenuator-64                          9kHz-2GHz                                                  N/A               II     11/15/2019       11/15/2018
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                 _____________________________________________________________
                    Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                          page 18 of 21


                             Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                  ______________________________________________________________________



Measurement Uncertainty

The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note
that the uncertainty values are provided for informational purposes only and are not used in determining
the PASS/FAIL results.

                                 Measurement                                   Expanded Uncertainty k=2   Maximum allowable uncertainty
                       Radiated Emissions (30-1000MHz)
                                    NIST                                                5.6dB                          N/A
                                   CISPR                                                4.6dB                     5.2dB (Ucispr)
                        Radiated Emissions (1-26.5GHz)                                  4.6dB                          N/A

                      Radiated Emissions (above 26.5GHz)                                4.9dB                          N/A

                          Magnetic Radiated Emissions                                   5.6dB                          N/A
                             Conducted Emissions
                                    NIST                                                3.9dB                          N/A
                                   CISPR                                                3.6dB                     3.6dB (Ucispr)
                      Telco Conducted Emissions (Current)                               2.9dB                          N/A

                      Telco Conducted Emissions (Voltage)                               4.4dB                          N/A

                             Electrostatic Discharge                                    11.5%                          N/A

                      Radiated RF Immunity (Uniform Field)                              1.6dB                          N/A

                            Electrical Fast Transients                                  23.1%                          N/A

                                     Surge                                              23.1%                          N/A

                            Conducted RF Immunity                                        3dB                           N/A

                               Magnetic Immunity                                        12.8%                          N/A

                               Dips and Interrupts                          2.3V                                       N/A

                                   Harmonics                                            3.5%                           N/A

                                     Flicker                                            3.5%                           N/A

                                                                                                  -8
                          Radio frequency (@ 2.4GHz)                                  3.23 x 10                      1 x 10-7

                              RF power, conducted                                       0.40dB                       0.75dB
    Maximum frequency deviation:
              Within 300Hz and 6kHz of audio frequency / Within 6kHz and               3.4%                           5%
               25kHz of audio frequency                                                 0.3dB                          3dB
                            Adjacent channel power                                      1.9dB                          3dB

        Conducted spurious emission of transmitter, valid up to 12.75GHz                2.39dB                         3dB

                        Conducted emission of receivers                                 1.3dB                          3dB

              Radiated emission of transmitter, valid up to 26.5GHz                     3.9dB                          6dB

               Radiated emission of transmitter, valid up to 80GHz                      3.3dB                          6dB

               Radiated emission of receiver, valid up to 26.5GHz                       3.9dB                          6dB

                Radiated emission of receiver, valid up to 80GHz                        3.3dB                          6dB

                                    Humidity                                            2.37%                          5%

                                  Temperature                                           0.7°C                         1.0°C

                                      Time                                              4.1%                          10%

                         RF Power Density, Conducted                                    0.4dB                          3dB

                         DC and low frequency voltages                                  1.3%                           3%

                             Voltage (AC, <10kHz)                                       1.3%                           2%

                                  Voltage (DC)                                          0.62%                          1%

    The above reflects a 95% confidence level


                           _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                              page 19 of 21


                             Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                  ______________________________________________________________________



Conditions Of Testing
     [Bureau Veritas Consumer Products Services, Inc., a Massachusetts corporation], and/or its affiliates (collectively, the
"Company") will conduct, at the request of the Submitter (“Client”), the tests specified on the submitted Test Request Form or equivalent in
accordance with, and subject to, the following terms and conditions (collectively, “Conditions”):
1. All orders for tests are subject to acceptance by the Company, and no order will constitute a binding commitment of the Company unless
and until such order is accepted by it, as evidenced by the issuance of a written report (“Test Report”) by the Company. The Test Report is
issued solely by the Company, is intended for the exclusive use of Client and shall not be published, used for advertising purposes, copied or
replicated for distribution to any other person or entity or otherwise publicly disclosed without the prior written consent of the Company. By
submitting a request for services to the Company, Client consents to the disclosure to accreditation bodies of those records of Client relevant
to the accreditation body's assessment of the Company's competence and compliance with relevant accreditation criteria. The Company
shall not be liable for any loss or damage whatsoever resulting from the failure of the Company to provide its services within any time period
for completion estimated by the Company. If Client anticipates using the Test Report in any legal proceeding, arbitration, dispute resolution
forum or other proceeding, it shall so notify the Company prior to submitting the Test Report in such proceeding. The Company has no
obligation to provide a fact or expert witness at such proceeding unless the Company agrees in advance to do so for a separate and
additional fee.
2. The Test Report will set forth the findings of the Company solely with respect to the test samples identified therein. Unless specifically
and expressly indicated in the Test Report, the results set forth in such Test Report are not intended to be indicative or representative of the
quality or characteristics of the lot from which a test sample is taken, and Client shall not rely upon the Test Report as being so indicative or
representative of the lot or of the tested product in general. The Test Report will reflect the findings of the Company at the time of testing
only, and the Company shall have no obligation to update the Test Report after its issuance. The Test Report will set forth the results of the
tests performed by the Company based upon the written information provided to the Company. The Test Report will be based solely on the
samples and written information submitted to the Company by Client, and the Company shall not be obligated to conduct any independent
investigation or inquiry with respect thereto.
3. The Company may, in its sole discretion, destroy samples which have been furnished to the Company for testing and which have not
been destroyed in the course of testing. The Company may delegate the performance of all or a portion of the services contemplated
hereunder to an affiliate, agent or subcontractor of the Company, and Client consents to such delegation.
4. These Conditions and the Test Report represent the entire understanding of the parties hereto with respect to the subject matter hereof
and of the Test Report, and no modification, variance or extrapolation with respect thereto shall be permitted without the prior written consent
of the Company.
5. The names, service marks, trademarks and copyrights of the Company and its affiliates, including the names “BUREAU VERITAS,”
“BUREAU VERITAS CONSUMER PRODUCTS SERVICES,” “BVCPS”, “MTL”, “ACTS”, “MTL-ACTS” and CURTIS-STRAUS
(collectively, the “Marks”) are and shall remain the sole property of the Company or its affiliates and shall not be used by Client except solely
to the extent that Client obtains the prior written approval of the Company and then only in the manner prescribed by the Company. Client
shall not contest the validity of the Marks or take any action that might impair the value or goodwill associated with the Marks or the image or
reputation of the Company or its affiliates.
6. Payment in full shall be due 30 days after the date of invoice. Interest shall be due on overdue amounts from the due date until paid at an
interest rate of 1.5% per month or, if less, the maximum rate permitted by law. The Company reserves the right, at any time and from time to
time, to revoke any credit extended to Client. Client shall reimburse the Company for any costs it incurs in collecting past due amounts,
including court costs and fees and expenses of attorneys and collection agencies. The Test Report may not be used or relied upon by Client
if and for so long as Client fails to pay when due any invoice issued by the Company or any affiliate of it to Client or any affiliate or subsidiary
of Client together with interest and penalties, if any, accrued thereon.
7. The Company disclaims any and all responsibility or liability arising out of or in connection with e-mail transmissions of such information.
8. Client understands and agrees that the Company is neither an insurer nor a guarantor, that the Company does not take the place of Client
or any designer, manufacturer, agent, buyer, distributor or transportation or shipping company, and that the Company disclaims all liability in
such capacities. Client further understands that if it seeks assurance against loss or damage, it should obtain appropriate insurance.
9. Client agrees that the Company, by providing the services, does not take the place of Client nor any third party, nor does the Company
release them from any of their obligations, nor does the Company otherwise assume, abridge, abrogate or undertake to discharge any duty
of any third party to Client or any duty of Client or any third party to any other third party, and Client will not release any third party from its
obligations and duties with respect to the tested goods.
10. Client shall, on a timely basis, (a) provide adequate instructions to the Company in order to enable the Company to perform properly its
services, (b) provide, or cause Client's suppliers and contractors to provide, the Company with all documents necessary to enable the
Company to perform its services, (c) furnish the Company with all relevant information regarding Client's intended use and purposes of the
tested goods, (d) advise the Company of essential dates and deadlines relevant to the tested goods and (e) fully exercise all rights and
remedies available to Client against third parties in respect of the tested goods.
11. The Company shall undertake due care and ordinary skill in the performance of its services to Client, and the Company shall accept
responsibility only were such skill has not been exercised and, even in such event, only to the extent of the limitation of liability set forth
herein.
12. If Client desires to assert a claim arising from or relating to (i) the performance, purported performance or non-performance of any
services by the Company or (ii) the sale, resale, manufacture, distribution or use of any tested goods, it must submit that claim to the
Company in a writing that sets forth with particularity the basis for such claim within 60 days from discovery of the potential claim and not
more than six months after the date of issuance of the Test Report to Client. Client waives any and all such claims including, without
limitation, claims that the Test Report is inaccurate, incomplete or misleading or that additional or different testing is required, unless and
then only to the extent that Client submits a written claim to the Company within both such time periods.
13. CLIENT SHALL, EXCEPT TO THE EXTENT OF COMPANY’S LIABILITY TO CLIENT HEREUNDER (WHICH IN NO EVENT SHALL
EXCEED THE LIMITATION OF LIABILITY HEREIN), HOLD HARMLESS AND INDEMNIFY THE COMPANY, ITS AFFILIATES AND THEIR
RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, AGENTS AND SUBCONTRACTORS AGAINST ALL ACTUAL OR ALLEGED
THIRD PARTY CLAIMS FOR LOSS, DAMAGE OR EXPENSE OF WHATSOEVER NATURE AND HOWSOEVER ARISING FROM OR
RELATING TO (i) THE PERFORMANCE, PURPORTED PERFORMANCE OR NON-PERFORMANCE OF ANY SERVICES BY THE
COMPANY OR (ii) THE SALE, RESALE, MANUFACTURE, DISTRIBUTION OR USE OF ANY TESTED GOODS.
14. EXCEPT AS MAY OTHERWISE BE EXPRESSLY AGREED TO IN WRITING BY THE COMPANY AND NOTWITHSTANDING ANY
PROVISION TO THE CONTRARY CONTAINED HEREIN OR IN ANY TEST REPORT, NO WARRANTY OR GUARANTEE, EXPRESS OR
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE, IS MADE.
                         _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                               page 20 of 21


                             Test Report for ASSA ABLOY Inc.  Report No. ES1024-4   February 28, 2019
                  ______________________________________________________________________

15. (A) IN NO EVENT WHATSOEVER SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL,
EXEMPLARY OR PUNITIVE DAMAGES IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE TEST REPORT OR THE
SERVICES PROVIDED BY THE COMPANY HEREUNDER, INCLUDING WITHOUT LIMITATION LOSS OF OR DAMAGE TO PROPERTY;
LOSS OF INCOME, PROFIT OR USE; OR ANY CLAIMS OR DEMANDS MADE AGAINST CLIENT OR ANY OTHER PERSON BY ANY
THIRD PARTY IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE SERVICES PROVIDED BY THE COMPANY
HEREUNDER.
  (B)NOTWITHSTANDING ANY PROVISION TO THE CONTRARY CONTAINED HEREIN, AND IN RECOGNITION OF THE RELATIVE
RISKS AND BENEFITS TO CLIENT AND THE COMPANY ASSOCIATED WITH THE TESTING SERVICES CONTEMPLATED HEREBY,
THE RISKS HAVE BEEN ALLOCATED SUCH THAT UNDER NO CIRCUMSTANCES WHATSOEVER SHALL THE LIABILITY OF THE
COMPANY TO CLIENT OR ANY THIRD PARTY IN RESPECT OF ANY CLAIM FOR LOSS, DAMAGE OR EXPENSE, OF WHATSOEVER
NATURE OR MAGNITUDE, AND HOWSOEVER ARISING, EXCEED AN AMOUNT EQUAL TO FIVE (5) TIMES THE AMOUNT OF THE
FEES PAID TO THE COMPANY FOR THE SPECIFIC SERVICES WHICH GAVE RISE TO SUCH CLAIM OR U.S.$10,000, WHICHEVER IS
THE LESSER AMOUNT.
16. The Company shall not be liable for any loss or damage resulting from any delay or failure in performance of its obligations hereunder
resulting directly or indirectly from any event of force majeure or any event outside the control of the Company. If any such event occurs, the
Company may immediately cancel or suspend its performance hereunder without incurring any liability whatsoever to Client.
 17. Company’s services, including these Conditions, shall be governed by, and construed in accordance with, the local laws of the country
where the Company performs the tests or, in the case of tests performed in the United States of America, the laws of Massachusetts without
regard to conflicts of laws principles. If any aspect(s) of these Conditions is found to be illegal or unenforceable, the validity, legality and
enforceability of all remaining aspects of these Conditions shall not in any way be affected or impaired thereby. Any proceeding related to
the subject matter hereof shall be brought, if at all, in the courts of the country where the Company performs the tests or, in the case of tests
performed in the United States of America, in the courts of Massachusetts. Client waives the right to interpose any counterclaim or setoffs of
any nature in any litigation arising hereunder.
The complete list of the Approved Subcontractors Curtis-Straus may use to delegate the performance of work can be provided upon request.
Rev.160009121(2)_#684340 v14CS




                         _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                             page 21 of 21



Document Created: 2019-02-28 10:10:27