Test report - FCC 15.225 Technical Report

FCC ID: U4A-SCYMCA1

Test Report

Download: PDF
FCCID_3061096

                                                                                                             Test Report
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS



                 Report No               EQ1125-1

                        Client           ASSA ABLOY Inc.


                    Address              110 Sargent Drive
                                         New Haven, CT, 06511

                       Phone             203-499-6836

             Items tested                Aperio V3 iN100
                 FCC ID                  U4A-SCYMCA1
                       IC                6982A-SCYMCA1
                     FRN                 0016550824

   Equipment Type                        Part 15 Low Power Communication Device Transmitter
   Equipment Code                        DXX
Emission Designator                      354KA1D

        FCC Rule Parts                   47 CFR 15.225, RSS-210 Issue 8

                Test Dates               05/16/2016 through 05/26/2016

                     Results             As detailed within this report



             Prepared by

                                             Jason Haley – Test Engineer

           Authorized by

                                             Yunus Faziloglu – Sr. EMC Engineer
                Issue Date
                                             7/11/2016

  Conditions of Issue                    This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’
                                         section on page 17 of this report.




Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under
Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation.
                           ____________________________________________________________
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                 One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                                                         page 1 of 18


                              Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
               ______________________________________________________________________




Contents

 Contents .................................................................................................................................. 2
 Summary ................................................................................................................................. 3
 Test Methodology .................................................................................................................... 4
 Product Tested - Configuration Documentation ....................................................................... 5
 Test Results ............................................................................................................................ 6
   Fundamental Emission......................................................................................................... 6
   Radiated Spurious Emissions .............................................................................................. 8
   Frequency Tolerance ......................................................................................................... 12
   99% Occupied Bandwidth .................................................................................................. 13
 Measurement Uncertainty...................................................................................................... 16
   Conditions Of Testing ........................................................................................................ 17


                                                                                                              Form Final Report REV 7-20-07 (DW)




                       ____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                            page 2 of 18


                              Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
               ______________________________________________________________________



Summary

This test report supports a “Limited Modular Approval” certification application of a transmitter
operating pursuant to 47 CFR 15.225 and RSS-210. The product is the Aperio V3 iN100. Its
operating frequency is 13.56MHz.

We found that the product met the above requirements without modifications. Steve Morse from
ASSA ABLOY Inc. was present during testing. The test sample was received in good condition.




Release Control Record
 Issue No.      Reason for change                 Date Issued
     1         Original Release                   July 11, 2016

                     _____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                            page 3 of 18


                              Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
               ______________________________________________________________________



Test Methodology

All testing was performed according to the following rules/procedures/documents;
CFR 47 Part 15.225, RSS-210 Issue 8, RSS-Gen Issue 4 and ANSI C63.10-2013.
Radiated Emissions were maximized by rotating the device around three orthogonal axes as
well as varying the test antenna’s height and polarity. The device antenna cannot be maximized
separately.

The EUT operating voltage is 9VDC from battery. Fresh batteries were used during testing.
The environmental conditions during each test are detailed in the results tables for each section.
The following bandwidths were used during radiated spurious and line conducted emissions.
            Frequency                                       RBW                                         VBW
           0.15-30MHz                                       9kHz                                        30kHz
           30-1000MHz                                      120kHz                                       1MHz
             1-25GHz                                        1MHz                                        3MHz

.




Release Control Record
 Issue No.      Reason for change                 Date Issued
     1         Original Release                   July 11, 2016

                     _____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                                page 4 of 18


                                  Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                   ______________________________________________________________________



Product Tested - Configuration Documentation
                                                                           EUT Configuration
           Work Order:         Q1125
             Company:          ASSA ABLOY Inc.
       Company Address:        110 Sargent Drive
                               New Haven, CT, 06511

                   Contact:    Steve Morse

                                                    MN                                             PN                                               SN
                  EUT:                             IN100                                          IN100                                              1
        EUT Description:       Aperio V3
     EUT Max Frequency:        2475 MHz
     EUT Min Frequency:        0.032 MHz

Support Equipment                                             MN                                                                        SN
Laptop computer                                               dell
Sargent 12V Supply                                           3521                                                                    Sample 1
Sargent 24V Supply                                           3520                                                                    Sample 1
AC/DC Brick                                             SYS1308-2424-W2                                                             SW-241PR

    Port Label           Port Type       # ports    # populated       cable type       shielded       ferrites      length (m)      in/out    under          comment
                                                                                                                                               test
DC Power input          Power DC        1           1               Power DC          No            No             10              in         yes        *not used for
                                                                                                                                                         emissions.
                                                                                                                                                         emissions done
                                                                                                                                                         with battery power
USB setup port          USB             1           1               USB               Yes           No             1               in         yes        *used to setup the
                                                                                                                                                         radio power and
                                                                                                                                                         channels

Software Operating Mode Description:
For emissions testing, the EUT will be operated by the client. Commands are given to the EUT over USB, setting up the radio parameters. Then the laptop and usb are
disconnected and the EUT continues operating in that mode until battery power is removed.

Performance Criteria:
Client operated




                          _____________________________________________________________
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                 One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                         page 5 of 18


                                    Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                     ______________________________________________________________________


Test Results

Fundamental Emission
LIMIT
The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848
microvolts/meter at 30 meters, (124 dBuV/m at 3m.)
[15.225 (a)]

MEASUREMENTS / RESULTS

Fundamental Radiated Emissions Table                                                               CSsoft Radiated Emissions Calculator               v 1.017.162
           Date: 17-May-16               Company: AssaAbloy                                                                              Work Order: Q1125
   Engineer: Jason Haley                 EUT Desc: Aperio V3 iN100                                            EUT Operating Voltage/Frequency: Battery
        Temp: 22°C                       Humidity: 27%                       Pressure: 1013mBar
                      Frequency Range: 1-30MHz                                                                Measurement Distance: 3 m
        Notes: Peak Readings                                                                                             EUT Max Freq: 13.56MHz

                                                                                                                                         FCC Part 15.225
   Antenna                                Pream p   Antenna   Cable     Adjusted
 Polarization     Frequency    Reading     Factor    Factor   Factor     Reading         Lim it      Margin      Result        Lim it        Margin             Result
   (0° - 90°)       (MHz)       (dBµV)      (dB)     (dB/m)    (dB)     (dBµV/m)        (dBµV/m)      (dB)     (Pass/Fail)    (dBµV/m)         (dB)           (Pass/Fail)
       0            13.56       26.8        0.0       39.2     0.4           66.4         ---          ---         ---         124.0          -57.6             Pass
      90            13.56       23.8        0.0       39.2     0.4           63.4         ---          ---         ---         124.0          -60.6             Pass

       Table Result:           Pass          by       -57.6 dB                                                            Worst Freq:           13.56 MHz
    Test Site: EMI Chamber 1             Cable 1: Asset #2051                                        Cable 2: Asset #1785                   Cable 3: ---
    Analyzer: MXE                        Preamp: none                                               Antenna: Sm Loop (high)              Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.162                                                                                          Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor




                              _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                               page 6 of 18


                 Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
  ______________________________________________________________________




        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 7 of 18


                                    Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                     ______________________________________________________________________



Radiated Spurious Emissions
LIMITS
The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not
exceed the general radiated emission limits in §15.209.
[15.225(d)]

MEASUREMENTS / RESULTS
Radiated Emissions Table                                                                           CSsoft Radiated Emissions Calculator               v 1.017.162
          Date: 17-May-16                Company: AssaAbloy                                                                              Work Order: Q1125
   Engineer: Jason Haley                 EUT Desc: Aperio V3 iN100                                            EUT Operating Voltage/Frequency: Battery
        Temp: 22°C                       Humidity: 27%                       Pressure: 1013mBar
                     Frequency Range: 9kHz-30MHz                                                              Measurement Distance: 3 m
        Notes: Peak Readings                                                                                             EUT Max Freq: 13.56MHz

                                                                                                                                         FCC Part 15.209
   Antenna                                Pream p   Antenna   Cable     Adjusted
 Polarization    Frequency     Reading     Factor    Factor   Factor     Reading         Lim it      Margin      Result        Lim it        Margin             Result
   (0° - 90°)      (MHz)       (dBµV)       (dB)     (dB/m)    (dB)     (dBµV/m)        (dBµV/m)      (dB)     (Pass/Fail)    (dBµV/m)         (dB)           (Pass/Fail)
      0           0.0135        24.3        0.0       82.2     0.0           106.5        ---          ---         ---         125.0          -18.5             Pass
     90           0.01279       25.8        0.0       82.6     0.0           108.4        ---          ---         ---         125.5          -17.1             Pass
      0           0.0143        24.8        0.0       81.8     0.0           106.6        ---          ---         ---         124.5          -17.9             Pass
      0           0.02597       23.7        0.0       77.2     0.0           100.9        ---          ---         ---         119.3          -18.4             Pass
     90           0.03279       29.2        0.0       75.5     0.0           104.7        ---          ---         ---         117.3          -12.6             Pass
      0           0.0441        27.7        0.0       72.6     0.0           100.3        ---          ---         ---         114.7          -14.4             Pass
     90           0.06275       24.1        0.0       69.0     0.0            93.1        ---          ---         ---         111.7          -18.6             Pass
      0           0.06281       24.7        0.0       69.0     0.0            93.7        ---          ---         ---         111.6          -17.9             Pass
     90           0.12162       14.8        0.0       63.7     0.1            78.6        ---          ---         ---         105.9          -27.3             Pass
      0           0.13152       15.2        0.0       63.2     0.1            78.5        ---          ---         ---         105.2          -26.7             Pass
   90, n.f.        0.296        15.9        0.0       57.0     0.1            73.0        ---          ---         ---          98.2          -25.2             Pass
    0, n.f.        0.296        14.7        0.0       57.0     0.1            71.8        ---          ---         ---          98.2          -26.4             Pass
   90, n.f.        6.319        11.2        0.0       42.5     0.3            54.0        ---          ---         ---          69.5          -15.5             Pass
    0, n.f.        6.412        10.7        0.0       42.4     0.3            53.4        ---          ---         ---          69.5          -16.1             Pass
    0, n.f.         20.5        13.0        0.0       37.7     0.4            51.1        ---          ---         ---          69.5          -18.4             Pass
   90, n.f.        29.58        12.6        0.0       36.7     0.5            49.8        ---          ---         ---          69.5          -19.7             Pass

       Table Result:           Pass          by       -12.6 dB                                                            Worst Freq:       0.03279 MHz
    Test Site: EMI Chamber 1             Cable 1: Asset #2051                                        Cable 2: Asset #1785                   Cable 3: ---
    Analyzer: MXE                        Preamp: none                                               Antenna: Sm Loop (high)              Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.162                                                                                          Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor




                             _____________________________________________________________
                  Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                  One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                page 8 of 18


                                        Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                         ______________________________________________________________________


Radiated Emissions Table                                                                                                   CSsoft Radiated Emissions Calculator                                     v 1.017.162
              Date: 17-May-16                         Company: AssaAbloy                                                                                                            Work Order: Q1125
    Engineer: Jason Haley                             EUT Desc: Aperio V3 iN100                                                           EUT Operating Voltage/Frequency: Battery
         Temp: 22°C                                       Humidity: 27%                           Pressure: 1013mBar
                             Frequency Range: 30-1000MHz                                                                                 Measurement Distance: 3 m
         Notes: Peak Readings                                                                                                                            EUT Max Freq: 13.56MHz

                                                                                                                                 ---                                                     FCC Class B
   Antenna                                                 Pream p       Antenna     Cable      Adjusted
 Polarization        Frequency           Reading           Factor        Factor      Factor      Reading          Lim it      Margin          Result                   Lim it              Margin              Result
    (H / V)             (MHz)             (dBµV)            (dB)          (dB/m)      (dB)       (dBµV/m)       (dBµV/m)        (dB)        (Pass/Fail)           (dBµV/m)                   (dB)            (Pass/Fail)
     Vert              257.65              42.4             25.5          11.9        1.2          30.0            ---           ---              ---                  46.0                 -16.0               Pass
     Vert              161.73              41.6             25.9          12.2        1.0          28.9            ---           ---              ---                  43.5                 -14.6               Pass
     Vert              501.74              41.3             25.3          18.1        1.4          35.5            ---           ---              ---                  46.0                 -10.5               Pass
     Vert              158.67              40.5             25.9          12.3        1.0          27.9            ---           ---              ---                  43.5                 -15.6               Pass
     Vert              528.86              40.2             25.3          17.9        1.8          34.6            ---           ---              ---                  46.0                 -11.4               Pass
     Vert              298.32              39.7             25.5          13.4        1.2          28.8            ---           ---              ---                  46.0                 -17.2               Pass
     Horiz             257.65              51.0             25.5          11.9        1.2          38.6            ---           ---              ---                  46.0                  -7.4               Pass
     Horiz             271.21              46.2             25.6          13.3        1.1          35.0            ---           ---              ---                  46.0                 -11.0               Pass
     Horiz             298.32              46.2             25.5          13.4        1.2          35.3            ---           ---              ---                  46.0                 -10.7               Pass
     Horiz             176.31              45.6             25.9          11.2        1.1          32.0            ---           ---              ---                  43.5                 -11.5               Pass
     Horiz             162.75              42.7             25.9          12.1        1.0          29.9            ---           ---              ---                  43.5                 -13.6               Pass
     Horiz              244.1              41.9             25.7          11.7        1.2          29.1            ---           ---              ---                  46.0                 -16.9               Pass

        Table Result:                    Pass                by              -7.4 dB                                                                     Worst Freq:                        257.65 MHz
    Test Site: EMI Chamber 1             Cable 1: Asset #2051                                                                 Cable 2: Asset #1785                                     Cable 3: ---
    Analyzer: MXE                        Preamp: Red-White                                                                   Antenna: Red-Brown                                     Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.162                                                                                                                                        Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor


Radiated Emissions Table                                                                                                               CSsoft Radiated Emissions Calculator                             v 1.017.162
         Date: 17-May-16                                    Company: AssaAbloy                                                                                                             Work Order: Q1125
   Engineer: Jason Haley                                    EUT Desc: Aperio V3 iN100                                                                   EUT Operating Voltage/Frequency: Battery
       Temp: 22°C                                            Humidity: 27%                                      Pressure: 1013mBar
                                  Frequency Range: 1-6GHz                                                                                               Measurement Distance: 3 m
        Notes: Noise Floor Readings                                                                                                                               EUT Max Freq: 13.56MHz
               13.56MHz Radio Active
                                                                                                                           FCC Class B High Frequency -                         FCC Class B High Frequency -
   Antenna                        Peak        Average         Pream p     Antenna    Cable     Adjusted       Adjusted                Peak                                                Average
 Polarization      Frequency     Reading      Reading          Factor      Factor    Factor   Peak Reading   Avg Reading    Lim it       Margin            Result               Lim it          Margin            Result
    (H / V)          (MHz)       (dBµV)           (dBµV)          (dB)      (dB/m)     (dB)     (dBµV/m)      (dBµV/m)     (dBµV/m)       (dB)           (Pass/Fail)       (dBµV/m)              (dB)           (Pass/Fail)
    Vert            1000.0       30.2              20.0           20.9      24.2       2.2       35.7           25.5        74.0          -38.3            Pass                 54.0             -28.5            Pass
    Vert            2000.0       27.0              17.3           19.1      28.0       3.0       38.9           29.2        74.0          -35.1            Pass                 54.0             -24.8            Pass
    Vert            3000.0       28.2              17.9           19.9      29.9       3.6       41.8           31.5        74.0          -32.2            Pass                 54.0             -22.5            Pass
    Vert            4000.0       28.6              17.5           18.9      32.6       4.5       46.8           35.7        74.0          -27.2            Pass                 54.0             -18.3            Pass
    Vert            5000.0       27.9              17.0           17.9      33.0       5.0       48.0           37.1        74.0          -26.0            Pass                 54.0             -16.9            Pass
    Vert            6000.0       28.7              16.8           17.5      34.1       6.4       51.7           39.8        74.0          -22.3            Pass                 54.0             -14.2            Pass
    Horz            1500.0       26.95             18.7           19.0      25.5       2.7       36.2           27.9        74.0          -37.8            Pass                 54.0             -26.1            Pass
    Horz            2500.0       27.5              18.9           20.2      28.5       3.6       39.4           30.8        74.0          -34.6            Pass                 54.0             -23.2            Pass
    Horz            3500.0       28.3              18.6           19.2      31.3       4.0       44.4           34.7        74.0          -29.6            Pass                 54.0             -19.3            Pass
    Horz            4500.0       28.0              17.4           17.9      32.4       4.7       47.2           36.6        74.0          -26.8            Pass                 54.0             -17.4            Pass
    Horz            5500.0       28.6              16.7           17.6      33.9       5.6       50.5           38.6        74.0          -23.5            Pass                 54.0             -15.4            Pass

       Table Result:                          Pass                 by        -14.2 dB                                                                               Worst Freq:                  6000.0 MHz
    Test Site: EMI Chamber 1                        Cable 1: Asset #2051                                                                 Cable 2: Asset #1785                                 Cable 3: ---
    Analyzer: MXE                                  Preamp: Asset #1517                                                                  Antenna: Orange Horn                               Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.162                                                                                                                                            Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor




                                   _____________________________________________________________
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                      One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                                           page 9 of 18


                                      Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                       ______________________________________________________________________

Radiated Emissions Table                                                                                                    CSsoft Radiated Emissions Calculator                  v 1.017.162
         Date: 17-May-16                           Company: AssaAbloy                                                                                                 Work Order: Q1125
   Engineer: Jason Haley                           EUT Desc: Aperio V3 iN100                                                              EUT Operating Voltage/Frequency: Battery
       Temp: 22°C                                  Humidity: 27%                                      Pressure: 1013mBar
                                Frequency Range: 6-18GHz                                                                               Measurement Distance: 1 m
        Notes: Noise Floor Readings                                                                                                                 EUT Max Freq: 13.56MHz
               13.56MHz Radio Active
                                                                                                                 FCC Class B High Frequency -                FCC Class B High Frequency -
   Antenna                     Peak     Average     Pream p   Antenna    Cable       Adjusted       Adjusted                Peak                                       Average
 Polarization   Frequency     Reading    Reading     Factor    Factor    Factor     Peak Reading   Avg Reading    Lim it      Margin        Result           Lim it      Margin             Result
    (H / V)        (MHz)       (dBµV)    (dBµV)       (dB)     (dB/m)        (dB)     (dBµV/m)      (dBµV/m)     (dBµV/m)       (dB)       (Pass/Fail)     (dBµV/m)        (dB)           (Pass/Fail)
    Vert         6000.0        27.3       17.8        17.5      34.8         6.4       51.0           41.5        83.5         -32.5         Pass            63.5          -22.0            Pass
    Horz         7000.0        27.91      16.7        16.3      36.0         6.7       54.3           43.1        83.5         -29.2         Pass            63.5          -20.4            Pass
    Vert         8000.0        27.1       17.0        16.5      37.4         6.3       54.3           44.2        83.5         -29.2         Pass            63.5          -19.3            Pass
    Horz         9000.0        27.92      17.2        17.4      37.9         6.7       55.1           44.4        83.5         -28.4         Pass            63.5          -19.1            Pass
    Vert         10000.0       27.8       17.2        17.1      38.4         8.4       57.5           46.9        83.5         -26.0         Pass            63.5          -16.6            Pass
    Horz         11000.0       26.2       17.4        16.5      38.5         8.1       56.3           47.5        83.5         -27.2         Pass            63.5          -16.0            Pass
    Vert         13000.0       28.2       17.6        15.6      40.7         9.6       62.9           52.3        83.5         -20.6         Pass            63.5          -11.2            Pass
    Horz         14000.0       30.3       18.2        16.5      42.3         8.6       64.7           52.6        83.5         -18.8         Pass            63.5          -10.9            Pass
    Horz         15000.0       30.3       19.1        17.0      39.5         8.7       61.5           50.3        83.5         -22.0         Pass            63.5          -13.2            Pass
    Vert         16000.0       31.6       20.8        16.5      37.9         9.1       62.1           51.3        83.5         -21.4         Pass            63.5          -12.2            Pass
    Horz         17000.0       30.2       20.1        16.3      43.0         9.3       66.2           56.1        83.5         -17.3         Pass            63.5           -7.4            Pass

       Table Result:                     Pass          by          -7.4 dB                                                                           Worst Freq:        17000.0 MHz
    Test Site: EMI Chamber 1                        Cable 1: Asset #2051                                                      Cable 2: Asset #1785                       Cable 3: ---
    Analyzer: MXE                                  Preamp: Asset #1517                                                       Antenna: Orange Horn                     Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.162                                                                                                                      Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor


Rev. 5/13/2016
      Spectrum Analyzers / Receivers /Preselectors                  Range               MN               Mfr            SN        Asset      Cat         Calibration Due           Calibrated on
                      MXE EMI Receiver                          20Hz-26.5GHz          N9038A           Agilent     MY51210181     2093        I             7/21/2016                7/21/2015
_
                 Radiated Emissions Sites                         FCC Code           IC Code        VCCI Code        Range                   Cat         Calibration Due           Calibrated on
                        EMI Chamber 1                               719150           2762A-6           A-0015      30-1000MHz                 II            3/21/2017                3/21/2015
_
         Preamps /Couplers Attenuators / Filters                    Range               MN               Mfr            SN        Asset      Cat         Calibration Due           Calibrated on
                          Red-White                            0.009-2000MHz ZFL-1000-LN                 CS            N/A        1258        II           12/27/2016               12/27/2015
_
                          Antennas                                  Range               MN               Mfr            SN        Asset      Cat         Calibration Due           Calibrated on
                       Red-Brown Bilog                           30-2000MHz             JB1             Sunol       A0032406      1218        I             12/4/2016                12/4/2014
                          Small Loop                            10kHz-30MHz         PLA-130/A           ARA            1024        755        I             5/29/2016                5/29/2014
_
                  Meteorological Meters                                                 MN               Mfr            SN        Asset      Cat         Calibration Due           Calibrated on
               Weather Clock (Pressure Only)                                          BA928      Oregon Scientific   C3166-1       831        I             4/28/2017                4/28/2016
                          TH A#2080                                                    HTC-1            HDE                       2080        II             4/5/2017                4/5/2016
_
                            Cables                                  Range                                Mfr                                 Cat         Calibration Due           Calibrated on
                         Asset #1785                            9kHz - 18GHz                         Florida RF                               II             1/5/2017                1/5/2016
                         Asset #2051                            9kHz - 18GHz                         Florida RF                               II             3/2/2017                3/2/2016
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.



Radiated Emissions Table                                                                                                    CSsoft Radiated Emissions Calculator                  v 1.017.162
         Date: 17-May-16                           Company: AssaAbloy                                                                                                 Work Order: Q1125
   Engineer: Jason Haley                           EUT Desc: Aperio V3 iN100                                                              EUT Operating Voltage/Frequency: Battery
       Temp: 22°C                                  Humidity: 27%                                      Pressure: 1013mBar
                                Frequency Range: 18-25GHz                                                                              Measurement Distance: 0.1 m
        Notes: Noise Floor Readings                                                                                                                 EUT Max Freq: 13.56MHz
               13.56MHz radio active
                                                                                                                 FCC Class B High Frequency -                FCC Class B High Frequency -
   Antenna                     Peak     Average     Pream p   Antenna    Cable       Adjusted       Adjusted                Peak                                       Average
 Polarization   Frequency     Reading    Reading     Factor    Factor    Factor     Peak Reading   Avg Reading    Lim it      Margin        Result           Lim it      Margin             Result
    (H / V)        (MHz)       (dBµV)    (dBµV)       (dB)     (dB/m)        (dB)     (dBµV/m)      (dBµV/m)     (dBµV/m)       (dB)       (Pass/Fail)     (dBµV/m)        (dB)           (Pass/Fail)
  Maximized      24135.0       41.9       41.9        40.9      40.3         6.9       48.2           48.2        103.5        -55.3         Pass            83.5          -35.3            Pass
  Maximized      18000.0       37.3       37.3        39.4      40.1         5.6       43.6           43.6        103.5        -59.9         Pass            83.5          -39.9            Pass
  Maximized      20000.0       37.9       37.9        41.6      40.2         6.1       42.6           42.6        103.5        -60.9         Pass            83.5          -40.9            Pass
  Maximized      22000.0       39.4       39.4        42.0      40.5         6.7       44.6           44.6        103.5        -58.9         Pass            83.5          -38.9            Pass
  Maximized      25000.0       39.6       39.6        40.9      40.3         7.0       46.0           46.0        103.5        -57.5         Pass            83.5          -37.5            Pass

       Table Result:                     Pass          by        -35.3 dB                                                                            Worst Freq:        24135.0 MHz
    Test Site: EMI Chamber 1                        Cable 1: EMIR-HIGH-07                                                     Cable 2: ---                               Cable 3: ---
    Analyzer: MXE                                  Preamp: 18-26.5GHz                                                        Antenna: 18-26.5GHz Horn                 Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.162                                                                                                                      Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor




                                _____________________________________________________________
                    Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                       page 10 of 18


                                        Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                         ______________________________________________________________________

Rev. 5/13/2016
      Spectrum Analyzers / Receivers /Preselectors                  Range                   MN                      Mfr            SN       Asset   Cat    Calibration Due     Calibrated on
                      MXE EMI Receiver                         20Hz-26.5GHz               N9038A                  Agilent      MY51210181   2093     I        7/21/2016          7/21/2015
_
                 Radiated Emissions Sites                        FCC Code                IC Code               VCCI Code         Range              Cat    Calibration Due     Calibrated on
                        EMI Chamber 1                               719150               2762A-6                  A-0015        1-18GHz              I        5/23/2017          5/23/2015
_
         Preamps /Couplers Attenuators / Filters                    Range                   MN                      Mfr            SN       Asset   Cat    Calibration Due     Calibrated on
                          HF (Yellow)                            18-26.5GHz      AFS4-18002650-60-8P-4              CS           467559     1266     II        3/8/2017          3/8/2016
_
                          Antennas                                  Range                   MN                      Mfr            SN       Asset   Cat    Calibration Due     Calibrated on
                       HF (White) Horn                           18-26.5GHz             801-WLM                  Waveline          758       758     III   Verify before Use    date of test
_                                                                                                                                                                                5/29/2014
                  Meteorological Meters                                                     MN                      Mfr            SN       Asset   Cat    Calibration Due     Calibrated on
               Weather Clock (Pressure Only)                                              BA928              Oregon Scientific  C3166-1      831     I        4/28/2017          4/28/2016
                          TH A#2080                                                        HTC-1                   HDE                      2080     II        4/5/2017          4/5/2016
_                                                                                                                                                                                4/5/2016
                            Cables                                  Range                                           Mfr                             Cat    Calibration Due     Calibrated on
                         REMI-High-07                            1 - 26.5GHz         TRU-21B0707-120               TRU                               II        8/7/2016          8/7/2015
_                                                                                                                                                                                1/5/2016
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.                                                               3/2/2016




                                   _____________________________________________________________
                     Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                     One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                          page 11 of 18


                                     Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                      ______________________________________________________________________



Frequency Tolerance
LIMITS
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating
frequency over a temperature variation of −20 degrees to + 50 degrees C at normal supply
voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply
voltage at a temperature of 20 degrees C. For battery operated equipment, the equipment tests
shall be performed using a new battery.
[15.225(e)]

MEASUREMENTS / RESULTS
Frequency Tolerance Table                                                                                   CSsoft Radiated Emissions Calculator            v 1.017.162
           Date: 18-May-16                 Company: AssaAbloy                                                                                     Work Order: Q1125
   Engineer: Jason Haley                   EUT Desc: Aperio V3 iN100                                                      EUT Operating Voltage/Frequency: Nominal is 12-24Vdc
       Temp: 22°C                          Humidity: 27%                              Pressure: 1013mBar
                      Frequency Range: 13.56MHz
        Notes: Peak Readings                                                                                                      EUT Max Freq: 13.56MHz
               RBW=100Hz, VBW=680Hz, Span=200Hz
                                                                                                                                  FCC Part 15.225
                             EUT            Measured Transm it
 Tem perature            Voltage                Frequency                    Lim it                   Upper Lim it              Low er Lim it                      Result
  (degrees C)                (V)                  (MHz)                 (+/- percentage)                 (MHz)                     (MHz)                          (Pass/Fail)
   20 (For
 Reference                   12.0             13.560120770                   N/A                           N/A                        N/A                             N/A
 Frequency)
     20                      10.2             13.560120230                  0.010                    13.56147678                13.55876476                         Pass
     20                      27.6             13.560119900                  0.010                    13.56147678                13.55876476                         Pass
     -20                     12.0             13.560141510                  0.010                    13.56147678                13.55876476                         Pass
      50                     12.0             13.560084580                  0.010                    13.56147678                13.55876476                         Pass

       Table Result:                Pass
    Test Site: EMI Chamber 1                Cable 1: Asset #2051                                                  Cable 2: Asset #1785                Cable 3: ---
    Analyzer: MXE                           Preamp: Red-White                                                    Antenna: Red-Brown                Preselector: ---
                                                                                                                                                             Co pyright Curtis-Straus LLC 2000




Rev. 5/13/2016
      Spectrum Analyzers / Receivers /Preselectors                 Range             MN              Mfr             SN       Asset      Cat    Calibration Due        Calibrated on
                      MXE EMI Receiver                         20Hz-26.5GHz        N9038A          Agilent       MY51210181   2093        I        7/21/2016             7/21/2015
_
                          Antennas                                 Range             MN              Mfr             SN       Asset      Cat    Calibration Due        Calibrated on
                          Small Loop                           10kHz-30MHz PLA-130/A                ARA             1024       755        I        5/29/2016             5/29/2014
_
                  Meteorological Meters                                              MN              Mfr             SN       Asset      Cat    Calibration Due        Calibrated on
               Weather Clock (Pressure Only)                                       BA928     Oregon Scientific     C3166-1     831        I        4/28/2017             4/28/2016
                          TH A#2086                                                 HTC-1           HDE                       2086        II        4/5/2017             4/5/2016
_
                            Cables                                 Range                             Mfr                                 Cat    Calibration Due        Calibrated on
                         Asset #1786                           9kHz - 18GHz                      Florida RF                               II        3/7/2017             3/7/2016
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                    _____________________________________________________________
                    Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                page 12 of 18


                                    Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                     ______________________________________________________________________



99% Occupied Bandwidth

REQUIREMENT
When an occupied bandwidth is not specified in the applicable RSS, the transmitted signal
bandwidth to be reported is to be its 99% emission bandwidth, as calculated or measured.
[RSS-GEN 4.6.1]

99% Occupied Bandwidth
    Date: 29-Jun-16                      Company: AssaAbloy                                                                     Work Order: Q1125
Engineer: Yunus Faziloglu                EUT Desc: Aperio V3 iN100                                         EUT Operating Voltage/Frequency: Battery
   Temp: 24.4°C                          Humidity: 54%                           Pressure: 1001mBar
                   Fundamental Frequency: 13.56MHz

                   Frequency                                                     Measured 99% Occupied Bandw idth
                     (MHz)                                                                    (kHz)
                     13.56                                                                    354.3
Test Site: CEMI1                          Cable 1: EMIR-15           Analyzer:        1510             Antenna: A00755                Cable 3: ---
                                                                                                                                Co pyright Curtis-Straus LLC 2000




                               _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                   page 13 of 18


                                      Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                       ______________________________________________________________________


Rev. 6/29/2016
                   Meteorological Meters                                           MN              Mfr                 SN      Asset   Cat   Calibration Due   Calibrated on
                 Weather Clock (Pressure Only)                                    BA928      Oregon Scientific       C3166-1    831     I       4/28/2018        4/28/2016
                          TH A#2082                                               HTC-1           HDE                          2082     II       4/5/2017        4/5/2016
_
     Spectrum Analyzers / Receivers /Preselectors                 Range             MN              Mfr             SN         Asset   Cat   Calibration Due   Calibrated on
                      Brown                                    9kHz-26.5GHz       E4407B           Agilent       SG44210511    1510     I       1/21/2017        1/21/2016
_
                          Antennas                                 Range       MN                   Mfr                SN      Asset   Cat   Calibration Due   Calibrated on
                          Small Loop                            10kHz-30MHz PLA-130/A               ARA               1024      755     I       6/14/2018        6/14/2016
_
                           Cables                                 Range                             Mfr                                Cat   Calibration Due   Calibrated on
                           REMI-15                              9kHz - 2GHz                         C-S                                 II      9/10/2016        9/10/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                               _____________________________________________________________
                     Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                     One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                  page 14 of 18


                                           Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                            ______________________________________________________________________


AC Line Conducted Emissions
LIMITS

            Frequency of    Quasi-peak limit      Average limit
           emission (MHz)        (dBµV)             (dBµV)
                   0.15-0.5     66 to 56*          56 to 46*
                      0.5-5         56                 46
                       5-30         60                 50
         *Decreases with the logarithm of the frequency.
[47 CFR 15.207(a)]

MEASUREMENTS / RESULTS
AC Side of a DC Supply Conducted Emissions
                       Date:   17-May-16                                                                  Company: AssaAbloy                                                    Work Order: Q1125
                   Engineer:   Chris Bramley                                                              EUT Desc: Aperio V3 iN100 - 13.56MHz Radio
                      Temp:    22.5 ºC                                                                    Humidity: 32%                                                           Pressure: 1001 mBar
                      Notes:   Sargent 12V DC Supply. To demonstrate compliance at 13.56MHz fundamental, the EUT antenna was removed and replaced with 50Ohm load
                                                                                                   Frequency Range: 0.15-30MHz                     EUT Input Voltage/Frequency: 120V/60Hz
                                        Quasi-Peak                 Average                 LISN
                                         Readings                 Readings                Factors           Cable      ATTN               FCC/CISPR Class B                   FCC/CISPR Class B
          Frequency                 QP1           QP2        AVG1         AVG2         L1          L2      Factor      Factor     QP Limit      Margin      Result    AVG Limit   Margin        Result
            (MHz)                 (dBµV)         (dBµV)     (dBµV)       (dBµV)       (dB)        (dB)       (dB)        (dB)      (dBµV)        (dB)     (Pass/Fail)  (dBµV)       (dB)      (Pass/Fail)
      0.15 with antenna             21.8          20.5        16.4         15.7       -0.1        -0.2       -0.1       -20.8        66.0       -23.2        Pass        56.0      -18.7         Pass
       0.8 with antenna              3.9           5.2         3.6          4.6       -0.1        -0.1       -0.1       -20.8        56.0       -29.8        Pass        46.0      -20.5         Pass
     0.985 with antenna              4.5           3.9         3.1          3.0       -0.1        -0.1       -0.1       -20.8        56.0       -30.6        Pass        46.0      -22.0         Pass
       1.7 with antenna              3.4           3.7         1.8          2.8       -0.1        -0.1       -0.1       -20.8        56.0       -31.3        Pass        46.0      -22.2         Pass
        5 with antenna               6.4           4.8         4.9          3.9       -0.1        -0.1       -0.2       -20.8        56.0       -28.6        Pass        46.0      -20.1         Pass
     13.56 with antenna             65.6                      64.6                    -0.1                   -0.2       -20.9        60.0        26.8        N/A         50.0      35.8          N/A
    13.56 without antenna           27.4          25.0        26.9         24.9       -0.1        -0.1       -0.2       -20.9        60.0       -11.4        Pass        50.0       -1.9         Pass

                 Result: Pass                                                                           Worst Margin:                 -1.9 dB               Frequency:            13.560 MHz
  Measurement Device: LISN ASSET 1730(Line 1) LISN ASSET 1731(Line 2)                                     Cable: CEMI-01                                Spectrum Analyzer: SA EMI Chamber (1327)
                                                                                                     Attenuator: 20dB Attenuator-07                                  Site: CEMI 5
C-S CEMI Calculator Version 3.0.14                                                                                                                                    Equipment Factor Sheet rev: 5/11/2016
Adjusted Reading = Raw Reading + LISN Insertion Loss + Cable Loss + Attenuation



Rev. 5/13/2016
      Spectrum Analyzers / Receivers /Preselectors                  Range              MN                Mfr           SN                      Asset     Cat     Calibration Due         Calibrated on
                  SA EMI Chamber (1327)                        9kHz-13.2 GHz        E4405B             Agilent     MY45103416                  1327       I         7/10/2016              7/10/2015
_
                LISNs/Measurement Probes                            Range              MN                Mfr           SN                       Asset    Cat     Calibration Due         Calibrated on
                       LISN Asset 1730                         150kHz-30MHz         LI-150A          Com-Power       201090                     1730      I         3/10/2017              3/10/2016
                       LISN Asset 1731                         150kHz-30MHz         LI-150A          Com-Power       201091                     1731      I         3/10/2017              3/10/2016
_
           Conducted Test Sites (Mains / Telco)                   FCC Code                           VCCI Code                                           Cat     Calibration Due         Calibrated on
                            CEMI 5                                  719150                             A-0015                                             III          NA                     N/A
_
                  Meteorological Meters                                                MN                Mfr           SN                       Asset    Cat     Calibration Due         Calibrated on
                          TH A#2082                                                  HTC-1               HDE                                    2082      II         4/5/2017              4/5/2016
                      Barometric A#2160                                            5396-0321 Monarch Instruments    4000060                     2160      I          3/7/2017              3/7/2016
_
                            Cables                                  Range                                Mfr                                             Cat     Calibration Due         Calibrated on
                           CEMI-01                               9kHz - 2GHz                             C-S                                              II        9/11/2016              9/11/2015
_
                         Attenuators                                Range              MN                Mfr           SN                       Asset    Cat     Calibration Due         Calibrated on
                      20dB Attenuator-07                          9kHz-2GHz       BW-N20W+               MCL          N/A                                 II        4/10/2017              4/10/2016
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                    _____________________________________________________________
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                      One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                           page 15 of 18


                                 Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                  ______________________________________________________________________


Measurement Uncertainty

The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note
that the uncertainty values are provided for informational purposes only and are not used in determining
the PASS/FAIL results.

                                 Measurement                                Expanded Uncertainty k=2   Maximum allowable uncertainty
                       Radiated Emissions (30-1000MHz)
                                    NIST                                             5.6dB                          N/A
                                   CISPR                                             4.6dB                     5.2dB (Ucispr)
                        Radiated Emissions (1-26.5GHz)                               4.6dB                          N/A

                      Radiated Emissions (above 26.5GHz)                             4.9dB                          N/A

                          Magnetic Radiated Emissions                                5.6dB                          N/A
                             Conducted Emissions
                                    NIST                                             3.9dB                          N/A
                                   CISPR                                             3.6dB                     3.6dB (Ucispr)
                      Telco Conducted Emissions (Current)                            2.9dB                          N/A

                      Telco Conducted Emissions (Voltage)                            4.4dB                          N/A

                             Electrostatic Discharge                                 11.5%                          N/A

                      Radiated RF Immunity (Uniform Field)                           1.6dB                          N/A

                            Electrical Fast Transients                               23.1%                          N/A

                                     Surge                                           23.1%                          N/A

                            Conducted RF Immunity                                     3dB                           N/A

                               Magnetic Immunity                                     12.8%                          N/A

                               Dips and Interrupts                                    2.3V                          N/A

                                   Harmonics                                         3.5%                           N/A

                                     Flicker                                         3.5%                           N/A
                                                                                               -8                          -7
                          Radio frequency (@ 2.4GHz)                               3.23 x 10                      1 x 10

                              RF power, conducted                                    0.40dB                       0.75dB
    Maximum frequency deviation:
              Within 300Hz and 6kHz of audio frequency / Within 6kHz and            3.4%                           5%
               25kHz of audio frequency                                              0.3dB                          3dB
                            Adjacent channel power                                   1.9dB                          3dB

        Conducted spurious emission of transmitter, valid up to 12.75GHz             2.39dB                         3dB

                        Conducted emission of receivers                              1.3dB                          3dB

              Radiated emission of transmitter, valid up to 26.5GHz                  3.9dB                          6dB

               Radiated emission of transmitter, valid up to 80GHz                   3.3dB                          6dB

               Radiated emission of receiver, valid up to 26.5GHz                    3.9dB                          6dB

                Radiated emission of receiver, valid up to 80GHz                     3.3dB                          6dB

                                    Humidity                                         2.37%                          5%

                                  Temperature                                        0.7°C                         1.0°C

                                      Time                                           4.1%                          10%

                         RF Power Density, Conducted                                 0.4dB                          3dB

                         DC and low frequency voltages                               1.3%                           3%

                             Voltage (AC, <10kHz)                                    1.3%                           2%

                                  Voltage (DC)                                       0.62%                          1%

    The above reflects a 95% confidence level




                           _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                      page 16 of 18


                                Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                 ______________________________________________________________________



Conditions Of Testing
[Bureau Veritas Consumer Products Services, Inc., a Massachusetts corporation], and/or its affiliates (collectively, the
"Company") will conduct, at the request of the Submitter (“Client”), the tests specified on the submitted Test Request Form or
equivalent in accordance with, and subject to, the following terms and conditions (collectively, “Conditions”):
1. All orders for tests are subject to acceptance by the Company, and no order will constitute a binding commitment of the
Company unless and until such order is accepted by it, as evidenced by the issuance of a written report (“Test Report”) by the
Company. The Test Report is issued solely by the Company, is intended for the exclusive use of Client and shall not be published,
used for advertising purposes, copied or replicated for distribution to any other person or entity or otherwise publicly disclosed
without the prior written consent of the Company. By submitting a request for services to the Company, Client consents to the
disclosure to accreditation bodies of those records of Client relevant to the accreditation body's assessment of the Company's
competence and compliance with relevant accreditation criteria. The Company shall not be liable for any loss or damage
whatsoever resulting from the failure of the Company to provide its services within any time period for completion estimated by the
Company. If Client anticipates using the Test Report in any legal proceeding, arbitration, dispute resolution forum or other
proceeding, it shall so notify the Company prior to submitting the Test Report in such proceeding. The Company has no obligation
to provide a fact or expert witness at such proceeding unless the Company agrees in advance to do so for a separate and additional
fee.
2. The Test Report will set forth the findings of the Company solely with respect to the test samples identified therein. Unless
specifically and expressly indicated in the Test Report, the results set forth in such Test Report are not intended to be indicative or
representative of the quality or characteristics of the lot from which a test sample is taken, and Client shall not rely upon the Test
Report as being so indicative or representative of the lot or of the tested product in general. The Test Report will reflect the findings
of the Company at the time of testing only, and the Company shall have no obligation to update the Test Report after its issuance.
The Test Report will set forth the results of the tests performed by the Company based upon the written information provided to the
Company. The Test Report will be based solely on the samples and written information submitted to the Company by Client, and the
Company shall not be obligated to conduct any independent investigation or inquiry with respect thereto.
3. The Company may, in its sole discretion, destroy samples which have been furnished to the Company for testing and which have
not been destroyed in the course of testing. The Company may delegate the performance of all or a portion of the services
contemplated hereunder to an affiliate, agent or subcontractor of the Company, and Client consents to such delegation.
4. These Conditions and the Test Report represent the entire understanding of the parties hereto with respect to the subject matter
hereof and of the Test Report, and no modification, variance or extrapolation with respect thereto shall be permitted without the prior
written consent of the Company.
5. The names, service marks, trademarks and copyrights of the Company and its affiliates, including the names “BUREAU
VERITAS,” “BUREAU VERITAS CONSUMER PRODUCTS SERVICES,” “BVCPS”, “MTL”, “ACTS”, “MTL-ACTS” and CURTIS-
STRAUS (collectively, the “Marks”) are and shall remain the sole property of the Company or its affiliates and shall not be used by
Client except solely to the extent that Client obtains the prior written approval of the Company and then only in the manner
prescribed by the Company. Client shall not contest the validity of the Marks or take any action that might impair the value or
goodwill associated with the Marks or the image or reputation of the Company or its affiliates.
6. Payment in full shall be due 30 days after the date of invoice. Interest shall be due on overdue amounts from the due date until
paid at an interest rate of 1.5% per month or, if less, the maximum rate permitted by law. The Company reserves the right, at any
time and from time to time, to revoke any credit extended to Client. Client shall reimburse the Company for any costs it incurs in
collecting past due amounts, including court costs and fees and expenses of attorneys and collection agencies. The Test Report
may not be used or relied upon by Client if and for so long as Client fails to pay when due any invoice issued by the Company or
any affiliate of it to Client or any affiliate or subsidiary of Client together with interest and penalties, if any, accrued thereon.
7. The Company disclaims any and all responsibility or liability arising out of or in connection with e-mail transmissions of such
information.
8. Client understands and agrees that the Company is neither an insurer nor a guarantor, that the Company does not take the
place of Client or any designer, manufacturer, agent, buyer, distributor or transportation or shipping company, and that the Company
disclaims all liability in such capacities. Client further understands that if it seeks assurance against loss or damage, it should obtain
appropriate insurance.
9. Client agrees that the Company, by providing the services, does not take the place of Client nor any third party, nor does the
Company release them from any of their obligations, nor does the Company otherwise assume, abridge, abrogate or undertake to
discharge any duty of any third party to Client or any duty of Client or any third party to any other third party, and Client will not
release any third party from its obligations and duties with respect to the tested goods.
10. Client shall, on a timely basis, (a) provide adequate instructions to the Company in order to enable the Company to perform
properly its services, (b) provide, or cause Client's suppliers and contractors to provide, the Company with all documents necessary
to enable the Company to perform its services, (c) furnish the Company with all relevant information regarding Client's intended use
and purposes of the tested goods, (d) advise the Company of essential dates and deadlines relevant to the tested goods and (e)
fully exercise all rights and remedies available to Client against third parties in respect of the tested goods.
11. The Company shall undertake due care and ordinary skill in the performance of its services to Client, and the Company shall
accept responsibility only were such skill has not been exercised and, even in such event, only to the extent of the limitation of
liability set forth herein.
12. If Client desires to assert a claim arising from or relating to (i) the performance, purported performance or non-performance of
any services by the Company or (ii) the sale, resale, manufacture, distribution or use of any tested goods, it must submit that claim
to the Company in a writing that sets forth with particularity the basis for such claim within 60 days from discovery of the potential
claim and not more than six months after the date of issuance of the Test Report to Client. Client waives any and all such claims
including, without limitation, claims that the Test Report is inaccurate, incomplete or misleading or that additional or different testing
is required, unless and then only to the extent that Client submits a written claim to the Company within both such time periods.


                       _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                     page 17 of 18


                                Test Report for ASSA ABLOY Inc.  Report No. EQ1125-1   July 11, 2016
                 ______________________________________________________________________

13. CLIENT SHALL, EXCEPT TO THE EXTENT OF COMPANY’S LIABILITY TO CLIENT HEREUNDER (WHICH IN NO EVENT
SHALL EXCEED THE LIMITATION OF LIABILITY HEREIN), HOLD HARMLESS AND INDEMNIFY THE COMPANY, ITS
AFFILIATES AND THEIR RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, AGENTS AND SUBCONTRACTORS AGAINST
ALL ACTUAL OR ALLEGED THIRD PARTY CLAIMS FOR LOSS, DAMAGE OR EXPENSE OF WHATSOEVER NATURE AND
HOWSOEVER ARISING FROM OR RELATING TO (i) THE PERFORMANCE, PURPORTED PERFORMANCE OR NON-
PERFORMANCE OF ANY SERVICES BY THE COMPANY OR (ii) THE SALE, RESALE, MANUFACTURE, DISTRIBUTION OR
USE OF ANY TESTED GOODS.
14. EXCEPT AS MAY OTHERWISE BE EXPRESSLY AGREED TO IN WRITING BY THE COMPANY AND NOTWITHSTANDING
ANY PROVISION TO THE CONTRARY CONTAINED HEREIN OR IN ANY TEST REPORT, NO WARRANTY OR GUARANTEE,
EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
OR USE, IS MADE.
15. (A) IN NO EVENT WHATSOEVER SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL,
INCIDENTAL, EXEMPLARY OR PUNITIVE DAMAGES IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE TEST
REPORT OR THE SERVICES PROVIDED BY THE COMPANY HEREUNDER, INCLUDING WITHOUT LIMITATION LOSS OF OR
DAMAGE TO PROPERTY; LOSS OF INCOME, PROFIT OR USE; OR ANY CLAIMS OR DEMANDS MADE AGAINST CLIENT OR
ANY OTHER PERSON BY ANY THIRD PARTY IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE SERVICES
PROVIDED BY THE COMPANY HEREUNDER.
    (B)NOTWITHSTANDING ANY PROVISION TO THE CONTRARY CONTAINED HEREIN, AND IN RECOGNITION OF THE
RELATIVE RISKS AND BENEFITS TO CLIENT AND THE COMPANY ASSOCIATED WITH THE TESTING SERVICES
CONTEMPLATED HEREBY, THE RISKS HAVE BEEN ALLOCATED SUCH THAT UNDER NO CIRCUMSTANCES
WHATSOEVER SHALL THE LIABILITY OF THE COMPANY TO CLIENT OR ANY THIRD PARTY IN RESPECT OF ANY CLAIM
FOR LOSS, DAMAGE OR EXPENSE, OF WHATSOEVER NATURE OR MAGNITUDE, AND HOWSOEVER ARISING, EXCEED
AN AMOUNT EQUAL TO FIVE (5) TIMES THE AMOUNT OF THE FEES PAID TO THE COMPANY FOR THE SPECIFIC
SERVICES WHICH GAVE RISE TO SUCH CLAIM OR U.S.$10,000, WHICHEVER IS THE LESSER AMOUNT.
16. The Company shall not be liable for any loss or damage resulting from any delay or failure in performance of its obligations
hereunder resulting directly or indirectly from any event of force majeure or any event outside the control of the Company. If any
such event occurs, the Company may immediately cancel or suspend its performance hereunder without incurring any liability
whatsoever to Client.
17. Company’s services, including these Conditions, shall be governed by, and construed in accordance with, the local laws of the
country where the Company performs the tests or, in the case of tests performed in the United States of America, the laws of
Massachusetts without regard to conflicts of laws principles. If any aspect(s) of these Conditions is found to be illegal or
unenforceable, the validity, legality and enforceability of all remaining aspects of these Conditions shall not in any way be affected or
impaired thereby. Any proceeding related to the subject matter hereof shall be brought, if at all, in the courts of the country where
the Company performs the tests or, in the case of tests performed in the United States of America, in the courts of Massachusetts.
Client waives the right to interpose any counterclaim or setoffs of any nature in any litigation arising hereunder.
          Rev.160009121(2)_#684340 v13CS




                       _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                    page 18 of 18



Document Created: 2017-12-10 00:00:10
Document Modified: 2017-12-10 00:00:10

© 2024 FCC.report