Test report_ET1639-3 FCC 15.209 Test Report 125kHz.pdf

FCC ID: U4A-MODBLE9118K

Test Report

Download: PDF
FCCID_4469676

BU REAU
                                         Bureau Veritas Consumer Products Services, Inc.


                                           ET1639—3

                                           ASSA ABLOY Inc.


                                           110 Sargent Drive
                                           New Haven, CT 06511

                                           203—821—5724



                                           IN—DIKP (Model BLE9118K)
                                           U4A—MODBLE118K
                                           6982A—MODBLE9118K
                                           0016550824

                                           Part 15 Low Power Transmitter Below 1705kHz
                                           DCD
                                           2K22A1D


                                           CFR Title 47 FCC Part 15.209, RSS—210 Issue 9 Section 4.4

                                           Jul 31 — Sep 3, 2019

                                           As detailed within this report



                                               Anna Vancheva — EMC Engineer


                                                        . _E
                                                Yurfds Fazilofi/— Sr.)%gineer


                                               9/23/2019




Bureau Veritas Consumer Products Services, Inc.is accredited by the American Association for Laboratory Accreditation for the specific scope of   @
accreditation under Certificate Number 1627—01. This report may contain data which is not covered by the A2LA accreditation.
                                                                                                                                                  |ACCREDITED
                                                                                                                                                  Gert No. 1627—01
        wy
     &
      (Groms3
             (a
                  Bureau Veritas Consumer Products Services, Inc.
     s        >
     a        o   One Distribution Center Circle, #1 » Littleton, MA « TEL (978) 486—8880 » FAX (978) 486—8828
                                                                                                                                            page 1 of 20
       1828
   B U R E A U
   MMGcNurts


              Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
              ______________________________________________________________________



Contents

 Contents .................................................................................................................................. 2
 Summary and Test Methodology ............................................................................................. 3
 Product Tested - Configuration Documentation ....................................................................... 4
 Compliance Statement ............................................................................................................ 5
 Modifications Required for Compliance ................................................................................... 5
 Test Results ............................................................................................................................ 6
   Radiated Emissions ............................................................................................................. 6
   Occupied Bandwidth 99% .................................................................................................. 12
   Measurement Uncertainty .................................................................................................. 18
 Conditions Of Testing ............................................................................................................ 19


                                                                                                              Form Final Report REV 2-16-07 (DW)




                       ____________________________________________________________
             Bureau Veritas Consumer Products Services, Inc.
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                            page 2 of 20


           Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
           ______________________________________________________________________



Summary and Test Methodology

Between July 31 and Sep 3 2019 we tested the IN-DIKP (Model BLE9118K) for compliance with
the following requirements:

CFR Title 47 FCC Part 15.209, RSS-210 Issue 9 Section 4.4

EUT transmits at 125 kHz. Emissions were measured with the EUT in its intended upright
installation orientation. EUT has an internal non-detachable coil loop antenna.

EUT includes a certified Bluetooth Low Energy module (FCC ID: TCZ-10103751G1 and
IC: 1175F-10103751G1).

Radiated emission testing was performed according to the procedures specified in ANSI
C63.10-2013 and RSS-Gen Issue 5.

AC mains conducted emission testing was performed for both 24VDC and PoE(48VDC)
configurations.

Following bandwidths were used during radiated and conducted spurious emissions testing.

         Frequency                                      RBW                                       VBW
        9kHz-150kHz                                    200Hz                                       1kHz
       150kHz-30MHz                                     9kHz                                      30kHz
        30MHz-1GHz                                     120kHz                                     1MHz

We found that the product met the above requirements with modification. See “Modifications
Required for Compliance” section of this report. The test sample was received in good
condition.




                 _____________________________________________________________
          Bureau Veritas Consumer Products Services, Inc.
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828    page 3 of 20


                  Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                  ______________________________________________________________________



Product Tested - Configuration Documentation

                                                                            EUT Configuration
            Work Order:          S1639
              Company:           Assa Abloy
        Company Address:         110 Sargent Drive
                                 New Haven, CT 06511

                    Contact:     Dave DeBiase

                                         Product Marketing Name                            Model Number                                SN
                   EUT:          IN-DIKP                                                    BLE9118K                                   1,2
         EUT Description:        Lock Controller
       EUT Tx Frequency:         125kHz (LF RFID), 13.56MHz (HF RFID)

     Port Label           Port Type           # ports   # populated    cable type    shielded     ferrites   length (m)   in/out   under        comment
                                                                                                                                    test
Ethernet Door             Ethernet        1             1             Ethernet      No          Yes          1.5          in       yes
Power DC                  Power DC        1             1             Power DC      No          No           5            in       yes
Ethernet frame            Ethernet        1             1             Ethernet      Yes         No           4.5          in       yes
Power AC                  Power AC        1             1             Power DC      No          yes          5            in       yes




Software Operating Mode Description:
All radios are transmitting during testing.




                            _____________________________________________________________
                  Bureau Veritas Consumer Products Services, Inc.
                  One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                               page 4 of 20


            Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
            ______________________________________________________________________



Compliance Statement

RSS-GEN       RSP-100         RSS 210          Part 15          Comments
   6.4                                          15.15(b)        There are no controls accessible to the user that
                                                                varies the output power.
                  3.1                             15.19         The label is shown in the label exhibit.
                  3.2                             15.21         Information to the user is shown in the instruction
                                                                manual exhibit.
                                                  15.27         See “Modifications Required for Compliance”
                                                                section below.
    3.2                                           15.31         The EUT was tested in accordance with the
                                                                measurement standards in this section.
  6.13.2                                          15.33         Frequency range was investigated according to this
                                                                section, unless noted in specific rule section under
                                                                which the equipment operates.
  6.13.1                                          15.35         The EUT emissions were measured using the
                                                                measurement detector and bandwidth specified in
                                                                this section, unless noted in specific rule section
                                                                under which the equipment operates.
    6.8                                          15.203         The antenna for this device is an internal non-
                                                                detachable coil loop antenna.
   8.10                                          15.205         The fundamental is not in a Restricted band and the
                                                 15.209         spurious and harmonic emissions in the Restricted
                                                                bands comply with the general emission limits of
                                                                15.209 or RSS-Gen as applicable
    8.8                                          15.207         AC mains emissions met the requirements of
                                                                15.207
    6.7                                                         99% emissions bandwidth plot is provided.


Modifications Required for Compliance
PoE configuration for radiated emissions was tested with ferrite Laird 28B0473-200 on all four Ethernet
pairs.




                  _____________________________________________________________
           Bureau Veritas Consumer Products Services, Inc.
           One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 5 of 20


                                   Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                   ______________________________________________________________________



Test Results

Radiated Emissions

9-150 kHz
Bureau Veritas Consumer Product Services Inc.                                                           Work Order - T1639
Radiated Emissions, Electric Field, 3m Measurement                                                      EUT Power Input - Battery
Top Peaks Perpendicular 9-150kHz                                                                        Test Site - CH1
Notes:                                                                                                  Conditions - 24.6°C; 46.8%RH; 1003mBar
BLE off.                                                                                                Test Engineer - AV




Data Taken at 06:08:37 PM, Tuesday, August 06, 2019
                                                                  Adjusted    Lim:
                                 Raw Peak        Correction         Peak   FCC_pt15_2        Peak        Peak Test         Worst         EUT
 Frequency                        Reading          Factor        Amplitude 09_dBµV/m        Margin        Results          Margin      Azimuth
  (MHz)                            (dBµV)          (dB/m)        (dBµV/m)        (dBµV/m)    (dB)       (Pass/Fail)         (dB)       (degrees)
 0.026033                            43.3           13.8            57.1           119.3    -62.2          PASS                          165
 0.080977                            36.7           10.6            47.3           109.4    -62.1          PASS                          195
 0.094809                            36.1           10.4            46.5           108.1    -61.6          PASS                          330
 0.109533                            36.8           10.2             47            106.8    -59.8          PASS                          270
 0.124994                            61.1           10.2            71.3           105.7    -34.4          PASS            -34.4         150
 0.140035                            32.3           10.2            42.4           104.7    -62.3          PASS                          285
Bureau Veritas Consumer Product Services Inc.                                                           Work Order - T1639
                                                                                                                                                                                 Work Or
RadiatedBureau
          Emissions,
                  Veritas Electric
                           Consumer    Field,
                                         Product3mServices
                                                    Measurement
                                                            Inc.                                        EUT
                                                                                                         PeakPower     Input
                                                                                                               Scan Data, 200Hz-RBW,
                                                                                                                                 Battery
                                                                                                                                     1kHz VBW
                                                                                                                                                                                 EUT Pow
Top Peaks Parallel 9-150kHz                                                                             Test Site - CH1
                                                                                                         Top Peaks                                                               Test Site
         Radiated Emissions, Electric Field, 3m Measurement
Notes:                                                                                                  Conditions     - 24.6°C; 46.8%RH; 1003mBar
                                                                                                         Limit: FCC_pt15_209_dBµV/m                                              Conditio
                                                                                                                                                                                 Test Eng
BLE off. Peak Data 9kHz - 150kHz Perpendicular Antenna Orientation                                      Test Engineer - AV
                                                                                                         Marginal Level
                             Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.                                                                                         EUT Max
                             Adjusted Amplitude = Raw Reading + Corr Factor.
                             Tile Version: 7.4.4.12, Profile Version 15 May, 2019.
                                                                                                     TE Used: EMI Chamber 2, MXE 1170725, 2615, 2606, 2455, None, None, None, None, None



Data Taken
     100
           at 06:08:37 PM, Tuesday, August 06, 2019
                                                                  Adjusted    Lim:
                        90       Raw Peak        Correction         Peak   FCC_pt15_2        Peak        Peak Test         Worst         EUT
 Frequency                        Reading          Factor        Amplitude 09_dBµV/m        Margin        Results          Margin      Azimuth
                        80
  (MHz)                            (dBµV)          (dB/m)        (dBµV/m)        (dBµV/m)    (dB)       (Pass/Fail)         (dB)       (degrees)
 0.03444
      70                             42.3           12.9             55            116.9    -61.8          PASS                          150
 0.058149                            38.6             11            49.6           112.3    -62.7          PASS                          225
                        60
 0.078319                            37.6           10.6            48.2           109.7    -61.6          PASS                          195
   Amplitude (dBµV/m)




 0.101443
      50                             35.7           10.2            45.8           107.5    -61.7          PASS                          120
 0.124934                            58.6           10.2            68.7           105.7     -37           PASS             -37          285
                        40
 0.142992                            32.7           10.2            42.7           104.5    -61.8          PASS                           15
                        30
                                                                                                                                                                                 Work Or
                                        _____________________________________________________________
                             Bureau Veritas Consumer Product Services Inc.        Peak Scan Data, 200Hz RBW, 1kHz VBW
                        20       Bureau Veritas Consumer Products Services, Inc.                                                                                                 EUT Pow
                                 One   Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880
                                                                                                     Top Peaks
                                                                                                            FAX (978) 486-8828                          page 6 of 20            Test Site
                             Radiated Emissions, Electric Field, 3m Measurement
                        10                                                                                Limit: FCC_pt15_209_dBµV/m                                             Conditio

                             Peak Data 9kHz - 150kHz Parallel Antenna Orientation                                                                                                Test Eng
                                                                                                          Marginal Level                                                         EUT Max
                        0 Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.
                          Adjusted Amplitude = Raw Reading + Corr Factor.


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


150-1000kHz

Bureau Veritas Consumer Product Services Inc.                                                            Work Order - T1639
Radiated Emissions Magnetic Field 3m Distance                                                            EUT Power Input - Battery
Top Peaks Parallel 150-1000kHz                                                                           Test Site - CH1
Notes:                                                                                                   Conditions - 24.6°C; 46.8%RH; 1003mBar
BLE off.                                                                                                 Test Engineer - AV




Data Taken at 06:26:51 PM, Tuesday, August 06, 2019
                                                                   Adjusted    Lim:
                                  Raw Peak        Correction         Peak   FCC_pt15_2        Peak        Peak Test       Worst           EUT
Frequency                          Reading          Factor        Amplitude 09_dBµV/m        Margin        Results        Margin        Azimuth
   (MHz)                            (dBµV)          (dB/s)        (dBµA/m)        (dBµA/m)    (dB)       (Pass/Fail)        (dB)        (degrees)
   0.519                              38.8           10.3             49             73.3    -24.3          PASS                            75
   0.575                              37.6           10.3            47.9            72.4    -24.6          PASS                           180
   0.666                              37.3           10.4            47.7            71.2    -23.5          PASS           -23.5           315
   0.777                              34.6           10.6            45.2            69.8    -24.6          PASS                           135
      0.85                            33.7           10.6            44.4             69     -24.7          PASS                           300
   0.937                              32.2           10.7            42.9            68.2    -25.3          PASS                           345
Bureau Veritas Consumer Product Services Inc.                                                            Work Order - T1639
                                                                                                                                                                                   Work Or
RadiatedBureau
          Emissions
                  VeritasMagnetic
                          Consumer Field
                                       Product 3m  Distance
                                                 Services   Inc.                                         EUT
                                                                                                          PeakPower     Input
                                                                                                                Scan Data,      - Battery
                                                                                                                           9kHz RBW, 30kHz VBW
                                                                                                                                                                                   EUT Pow
Top Peaks Perpendicular 150-1000kHz                                                                      Test Site - CH1
                                                                                                          Top Peaks                                                                Test Site
         Radiated Emissions, Magnetic Field, 3m Measurement
Notes:                                                                                                   Conditions     - 24.6°C; 46.8%RH; 1003mBar
                                                                                                          Limit: FCC_pt15_209_dBµV/m                                               Conditio

BLE off. Peak Data 150kHz - 1MHz Parallel Antenna Orientation                                            Test Engineer
                                                                                                          Marginal Level
                                                                                                                            - AV                                                   Test Eng
                              Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.                                                                                          EUT Max
                              Adjusted Amplitude = Raw Reading + Corr Factor.
                              Tile Version: 7.4.4.12, Profile Version 15 May, 2019.
                                                                                                      TE Used: EMI Chamber 2, MXE 1170725, 2615, 2606, 2455, 2456, None, None, None, None



Data Taken
     100
           at 06:26:51 PM, Tuesday, August 06, 2019
                                                                   Adjusted    Lim:
                        90        Raw Peak        Correction         Peak   FCC_pt15_2        Peak        Peak Test       Worst           EUT
Frequency                          Reading          Factor        Amplitude 09_dBµV/m        Margin        Results        Margin        Azimuth
                        80
   (MHz)                            (dBµV)          (dB/s)        (dBµA/m)        (dBµA/m)    (dB)       (Pass/Fail)        (dB)        (degrees)
   0.568
       70                             38.6           10.3            48.9            72.6    -23.6          PASS           -23.6           210
   0.634                              37.3           10.4            47.7            71.6    -23.9          PASS                            0
                        60
   0.739                              35.2           10.5            45.8            70.3    -24.5          PASS                           285
   Amplitude (dBµA/m)




   0.792
       50                             34.4           10.6             45             69.6    -24.6          PASS                            30
   0.851                              33.4           10.6             44              69      -25           PASS                           195
                        40
   0.922                               33            10.7            43.7            68.3    -24.6          PASS                           345
                        30
                                                                                                           Peak Scan Data, 9kHz RBW, 30kHz VBW                                     Work Or
                              Bureau Veritas Consumer Product Services Inc.
                        20                                                                                                                                                         EUT Pow
                                                                                                           Top Peaks                                                               Test Site
                              Radiated Emissions, Magnetic Field, 3m Measurement
                        10                                                                                 Limit: FCC_pt15_209_dBµV/m                                              Conditio

                              Peak Data 150kHz - 1MHz Perpendicular Antenna Orientation                                                                                       Test Eng
                                                                                                    Marginal Level                                                            EUT Max
                          0 Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.
                                           _____________________________________________________________
                            Adjusted Amplitude  = Raw Reading + Corr Factor.
                                  Bureau7.4.4.12,
                            Tile Version:  Veritas   Consumer
                                                  Profile Version 15Products
                                                                      May, 2019. Services, Inc.
                        -10      One Distribution Center Circle, #1  Littleton, MA  TEL (978)TE486-8880
                                                                                                  Used: EMI Chamber 2, 486-8828
                                                                                                             FAX (978)                                     page 7 of 20
                                                                                                                        MXE 1170725, 2615, 2606, 2455, 2456, None, None, None, None


                        -20
                        100

                        -30
                          150K


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


1-30 MHz

Bureau Veritas Consumer Product Services Inc.                                                            Work Order - T1639
Radiated Emissions Magnetic Field 3m Distance                                                            EUT Power Input - Battery
Top Peaks Parallel 1-30MHz                                                                               Test Site - CH1
Notes:                                                                                                   Conditions - 24.6°C; 46.8%RH; 1003mBar
BLE off.                                                                                                 Test Engineer - AV




Data Taken at 10:07:49 AM, Friday, August 09, 2019
                                                                   Adjusted    Lim:
                                  Raw Peak        Correction         Peak   FCC_pt15_2        Peak        Peak Test       Worst           EUT
 Frequency                         Reading          Factor        Amplitude 09_dBµV/m        Margin        Results        Margin        Azimuth
   (MHz)                            (dBµV)          (dB/s)        (dBµA/m)        (dBµA/m)    (dB)       (Pass/Fail)        (dB)        (degrees)
   1.081                              29.5           10.7            40.2            66.9    -26.8          PASS                          285
   1.803                              26.2           10.6            36.8            69.5    -32.8          PASS                          255
   2.614                              22.4           10.6             33             69.5    -36.6          PASS                          345
   3.309                              20.2           10.7            30.8            69.5    -38.7          PASS                          240
   13.56                              51.6           11.2            62.8            69.5     -6.7          PASS            -6.7          135
                 30                   11.5            8.3            19.7             40     -20.3          PASS                           45
Bureau Veritas Consumer Product Services Inc.                                                            Work Order - T1639
                                                                                                                                                                                  Work Or
RadiatedBureau
         Emissions
                 VeritasMagnetic
                         Consumer Field
                                      Product 3m  Distance
                                                Services Inc.                                            EUT
                                                                                                          PeakPower     Input
                                                                                                                Scan Data,      - Battery
                                                                                                                           9kHz RBW, 30kHz VBW
                                                                                                                                                                                  EUT Pow
Top Peaks Perpendicular 1-30MHz                                                                          Test Site - CH1
                                                                                                          Top Peaks                                                               Test Site
        Radiated Emissions, Magnetic Field, 3m Measurement
Notes:                                                                                                   Conditions     - 24.6°C; 46.8%RH; 1003mBar
                                                                                                          Limit: FCC_pt15_209_dBµV/m                                              Conditio
                                                                                                                                                                                  Test Eng
                              Peak Data 1-30MHz Parallel Antenna Orientation                             Test Engineer
                                                                                                          Marginal Level
                                                                                                                            - AV
                              Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.                                                                                         EUT Max
BLE off.                      Adjusted Amplitude = Raw Reading + Corr Factor.
                              Tile Version: 7.4.4.12, Profile Version 15 May, 2019.
                                                                                                      TE Used: EMI Chamber 1, MXE 2093, 2615, 2585, 2456, None, None, None, None, None



Data Taken at 04:24:08 PM, Tuesday, August 06, 2019
                        100
                                                                   Adjusted    Lim:
                        90        Raw Peak        Correction         Peak   FCC_pt15_2        Peak        Peak Test       Worst           EUT
 Frequency                         Reading          Factor        Amplitude 09_dBµV/m        Margin        Results        Margin        Azimuth
                        80
   (MHz)                            (dBµV)          (dB/s)        (dBµA/m)        (dBµA/m)    (dB)       (Pass/Fail)        (dB)        (degrees)
   1.064
       70                             30.3           10.7             41             67.1    -26.1          PASS                          345
   1.589                              25.3           10.6            35.9            63.6    -27.7          PASS                          135
       60
   2.536                              22.9           10.6            33.5            69.5    -36.1          PASS                          165
   Amplitude (dBµA/m)




  13.559
      50
                                      52.3           11.2            63.5            69.5     -6.1          PASS            -6.1          300
  28.674                               23             8.7            31.7            69.5    -37.8          PASS                            0
                        40
                 30                   11.5            8.3            19.8             40     -20.2          PASS                            0
                        30
In 9kHz-30MHz      range,   no emissions     were Inc.found in receive loop  antenna’s       “ground-parallel”
                                                                       Peak Scan Data, 9kHz RBW, 30kHz VBW                                                                        Work Or
         Bureau Veritas Consumer Product Services
                                                                                                                                                                                  EUT Pow
orientation.
      20
                                                                       Top Peaks                                                                                                  Test Site
                              Radiated Emissions, Magnetic Field, 3m Measurement
                                                                                                           Limit: FCC_pt15_209_dBµV/m                                             Conditio
                        10
                              Peak Data 1-30MHz Perpendicular Antenna Orientation                                                                                            Test Eng
                                                                                                    Marginal Level                                                           EUT Max
                          0 Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.
                                           _____________________________________________________________
                            Adjusted Amplitude  = Raw Reading + Corr Factor.
                                  Bureau7.4.4.12,
                            Tile Version:  Veritas   Consumer
                                                  Profile Version 15Products
                                                                      May, 2019. Services, Inc.
                        -10      One Distribution Center Circle, #1  Littleton, MA  TEL (978)TE486-8880
                                                                                                  Used: EMI Chamber 1, 486-8828
                                                                                                             FAX (978)                                    page 8 of 20
                                                                                                                        MXE 2093, 2615, 2585, 2456, None, None, None, None, None


                        -20
                        100

                        -30


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


30-1000 MHz

Bureau Veritas Consumer Product Services Inc.                                                                Work Order - T1639
Radiated Emissions Electric Field 3m Distance                                                                EUT Power Input - Battery
Top Peaks Vertical 30-1000MHz                                                                                Test Site - CH1
Notes:                                                                                                        Conditions - 24.6°C; 46.8%RH; 1003mBar
BLE off.                                                                                                     Test Engineer - AV




Data Taken at 06:04:10 PM, Saturday, August 03, 2019
                                                                    Adjusted    Lim1:                                         Worst
                                     Peak          Correction         Peak   FCC_pt15_2           Lim1        Lim1 Test       Margin         Antenna       Turntable
Frequency                           Reading          Factor        Amplitude      09             Margin        Results         Lim1           Height        Azimuth
   (MHz)                            (dBµV)           (dB/m)        (dBµV/m)           (dBµV/m)    (dB)       (Pass/Fail)        (dB)           (cm)        (degrees)
  30.097                              31.6            -6.7            24.9              40       -15.1           PASS          -15.1           200            270
 152.802                              38.4            -15.1           23.3              43.5     -20.2           PASS                          100            180
  155.93                              39.4             -15            24.3              43.5     -19.2           PASS                          100            180
  157.87                              37.7            -15.1           22.6              43.5     -20.9           PASS                          100            180
 159.059                              38.4            -15.1           23.3              43.5     -20.2           PASS                          100            180
 937.726                              31.6            -1.2            30.4              46       -15.6           PASS                          100             45

                                                                                                              Peak Scan Data, 120kHz RBW, 300kHz VBW                                    Work Or
Bureau Veritas    Consumer
        Bureau Veritas            Product
                           Consumer            Services
                                         Product   ServicesInc.Inc.                                          Work    Order - T1639
                                                                                                                                                                                        EUT Pow
                                                                                                              Top Peaks
Radiated Emissions Electric Field 3m Distance                                                                EUT Power Input - Battery                                                  Test Site
        Radiated Emissions, Electric Field, 3m Test Distance                                                  Limit 1: FCC_pt15_209
Top Peaks Horizontal 30-1000MHz                                                                              Test Site - CH1                                                            Conditio
                                                                                                              Limit 2: FCC_pt15_209
Notes: Peak Data 30-1000MHz Vertical Antenna Polarity                                                         Conditions - 24.6°C; 46.8%RH; 1003mBar                                    Test Eng
                                                                                                              Marginal Level                                                            EUT Max
BLE off Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp.
        Adjusted Amplitude = Raw Reading + Corr Factor.                                                      Test Engineer - AV
                              Tile Version: 7.4.4.12, Profile Version 15 May, 2019.
                                                                                                          TE Used: EMI Chamber 1, MXE 2093, 1106, 2585, 2464, 2456, 2311, None, None, None




Data Taken at 06:04:10 PM, Saturday, August 03, 2019
                         70
                                                                    Adjusted    Lim1:                                         Worst
                                     Peak          Correction         Peak   FCC_pt15_2           Lim1        Lim1 Test       Margin         Antenna          EUT
Frequency                           Reading          Factor        Amplitude      09             Margin        Results         Lim1           Height        Azimuth
                         60
   (MHz)                            (dBµV)           (dB/m)        (dBµV/m)           (dBµV/m)    (dB)       (Pass/Fail)        (dB)           (cm)        (degrees)
  30.145                              32.8            -6.7             26.1             40       -13.9           PASS                          100             90
 124.793
      50                               33             -13.1            19.9             43.5     -23.6           PASS                          200             90
    Amplitude (dBµV/m)




 197.713                              33.5            -14.6            18.9             43.5     -24.6           PASS                          250            315
 701.337                              50.9            -5.1             45.8             46        -0.2           PASS           -0.2           250             45
                         40
 702.646                              40.1            -5.1              35              46        -11            PASS                          100            315
 946.141                              31.8              -1             30.8             46       -15.2           PASS                          100              0

                         30
                                                                                                               Peak Scan Data, 120kHz RBW, 300kHz VBW                                   Work Or
                              Bureau Veritas Consumer Product Services Inc.
                                                                                                                                                                                        EUT Pow
                                                                                                               Top Peaks
                                                                                                                                                                                        Test Site
                              Radiated Emissions, Electric Field, 3m Test Distance                             Limit 1: FCC_pt15_209
                         20                                                                                                                                                             Conditio
                                                                                          Limit 2: FCC_pt15_209
                              Peak Data 30-1000MHz   Horizontal Antenna Polarity                                                                                                        Test Eng
                                             _____________________________________________________________
                              Corr Factor = Ant + Cab + Filter + Presel + Atten - Preamp. Marginal Level                                                                                EUT Max
                                   Bureau Veritas Consumer Products Services, Inc.
                                  One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                              Adjusted Amplitude = Raw Reading + Corr Factor.                                                                                  page 9 of 20
                         10 Tile Version: 7.4.4.12, Profile Version 15 May, 2019.
                                                                                                          TE Used: EMI Chamber 1, MXE 2093, 1106, 2585, 2464, 2456, 2311, None, None, None




                          0


                      Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                      ______________________________________________________________________


Test Equipment Used

Rev. 7/24/2019
    Spectrum Analyzers / Receivers /Preselectors                      Range              MN          Mfr             SN         Asset      Cat    Calibration Due
                 2093 MXE EMI Receiver                         20Hz-26.5GHz N9038A                 Agilent       MY51210181 2093             I        11/21/2019
_
               Radiated Emissions Sites                          FCC Code              IC Code VCCI Code           Range        Asset      Cat    Calibration Due
                        EMI Chamber 1                                 719150           2762A-6     A-0015        30-1000MHz 1685             I        12/7/2020
_
       Preamps /Couplers Attenuators / Filters                        Range              MN          Mfr             SN         Asset      Cat    Calibration Due
                           2311 PA                               1-1000MHz           PAM-103COM-POWER 441174                    2311         II       10/29/2019
_
                          Antennas                                    Range              MN          Mfr             SN         Asset      Cat    Calibration Due
                        Red-Black Bilog                         30-2000MHz               JB1        Sunol        A091604-2      1106         I        4/26/2021
_
            Meteorological Meters/Chambers                                               MN          Mfr             SN         Asset      Cat    Calibration Due
             Weather Clock (Pressure Only)                                             BA928Oregon ScientificC3166-1             831         I        5/15/2020
                         Asset #2658                                                   1235C97
                                                                                            Control Company
                                                                                                          181683808             2658         I           4/3/2020
_
                            Cables                                    Range                          Mfr                                   Cat    Calibration Due
                         Asset #2456                            9KHz-18GHz                        MegaPhase                                  II       10/31/2019
                         Asset #2464                            9KHz-18GHz                        MegaPhase                                  II       10/31/2019
                         Asset #2585                            9KHz-18GHz                        Pasternack                                 II       5/24/2020
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.


30-1000MHz PoE (48VDC)

Bureau Veritas Consumer Product Services Inc.                    Work Order - T1639
Radiated Emissions Electric Field 3m Distance                    EUT Power Input - POE (48Vdc)
Top Peaks Horizontal 30-1000MHz                                  Test Site - CH-1
Notes:                                                           Conditions - 23.7°C; 56%RH; 1008mBar
BLE9118K, with ferrite: Laird 28B0473-200 on all four Ethernet pairs;
with metal escutcheon                                            Test Engineer - AKZ



Data Taken at 03:15:32 PM, Wednesday, July 31, 2019
                                        Adjusted    Lim1:                                Worst        Lim2:                              Worst
               Peak       Correction     Peak    FCC_pt15_1    Lim1      Lim1 Test       Margin    Cispr_Class     Lim2    Lim2 Test     Margin   Antenna      EUT
Frequency     Reading       Factor     Amplitude 09_Class_B   Margin      Results         Lim1          _B        Margin    Results       Lim2     Height    Azimuth
    (MHz)     (dBµV)       (dB/m)      (dBµV/m)   (dBµV/m)     (dB)      (Pass/Fail)      (dB)      (dBµV/m)       (dB)    (Pass/Fail)    (dB)     (cm)      (degrees)
 294.495       50.9         -13.5        37.4       46         -8.7        PASS                       47.5        -10.1      PASS                  100         225
 297.526       51.6         -13.5        38.2       46         -7.9        PASS                       47.5         -9.3      PASS                  100         225
 300.509        51          -13.4        37.7       46         -8.3        PASS                       47.5         -9.8      PASS                  100         225
 375.029       50.1         -11.1        38.9       46         -7.1        PASS                       47.5         -8.6      PASS                  100          90
 500.014       46.7         -8.3         38.4       46         -7.6        PASS                       47.5         -9.1      PASS                  150          45
 625.022       46.4         -6.3          40        46          -6         PASS            -6         47.5         -7.5      PASS         -7.5     100         225




                              _____________________________________________________________
                  Bureau Veritas Consumer Products Services, Inc.
                  One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                               page 10 of 20


                      Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                      ______________________________________________________________________

Bureau Veritas Consumer Product Services Inc.                    Work Order - T1639
Radiated Emissions Electric Field 3m Distance                    EUT Power Input - POE (48Vdc)
Top Peaks Vertical 30-1000MHz                                    Test Site - CH-1
Notes:                                                           Conditions - 23.7°C; 56%RH; 1008mBar
BLE9118K, with ferrite: Laird 28B0473-200 on all four Ethernet pairs;
with metal escutcheon                                            Test Engineer - AKZ



Data Taken at 03:15:32 PM, Wednesday, July 31, 2019
                                       Adjusted    Lim1:                               Worst       Lim2:                                  Worst
               Peak      Correction     Peak    FCC_pt15_1    Lim1      Lim1 Test      Margin   Cispr_Class       Lim2      Lim2 Test     Margin         Antenna     Turntable
Frequency     Reading      Factor     Amplitude 09_Class_B   Margin      Results        Lim1         _B          Margin      Results       Lim2           Height      Azimuth
    (MHz)     (dBµV)      (dB/m)      (dBµV/m)   (dBµV/m)     (dB)      (Pass/Fail)     (dB)    (dBµV/m)          (dB)      (Pass/Fail)    (dB)           (cm)       (degrees)
    36.111     45.4        -11.1        34.3       40         -5.7        PASS                     40.5           -6.2        PASS                        100          225
    37.154      43         -11.8        31.2       40         -8.8        PASS                     40.5           -9.3        PASS                        100           90
 625.022       45.7        -6.3         39.4       46         -6.6        PASS                     47.5           -8.1        PASS                        150          270
 750.055       41.2        -4.2          37        46          -9         PASS                     47.5          -10.5        PASS                        100          225
 822.611       44.1        -2.9         41.2       46         -4.8        PASS                     47.5           -6.3        PASS                        200          180
Data Taken at 04:28:17 PM, Wednesday, July 31, 2019
                                                   Lim1:                               Worst       Lim2:                                  Worst
              Raw QP     Correction Adjusted QP FCC_pt15_1 Margin to Test Results      Margin   Cispr_Class     Margin to Test Results    Margin         Antenna       EUT
Frequency     Reading      Factor    Amplitude 09_Class_B   Lim1        Lim1            Lim1         _B          Lim2        Lim2          Lim2           Height     Azimuth
    (MHz)     (dBµV)      (dB/m)      (dBµV/m)   (dBµV/m)     (dB)      (Pass/Fail)     (dB)    (dBµV/m)          (dB)      (Pass/Fail)    (dB)           (cm)       (degrees)
 174.687       46.6        -16.3        30.3       43.5      -13.2        PASS                     40.5          -10.2        PASS        -10.2           152           29
 390.032       45.4        -11.1        34.3       46        -11.7        PASS         -11.7       47.5          -13.2        PASS                        144          260


Test Equipment Used

Rev. 7/30/2019
     Spectrum Analyzers / Receivers /Preselectors                     Range             MN                Mfr                 SN          Asset Cat Calibration Due
                  2093 MXE EMI Receiver                         20Hz-26.5GHz N9038A                   Agilent             MY51210181 2093           I        11/21/2019
_
                Radiated Emissions Sites                             FCC Code         IC Code      VCCI Code                Range         Asset Cat Calibration Due
                        EMI Chamber 1                                 719150          2762A-6         A-0015              30-1000MHz 1685           I            12/7/2020
                        EMI Chamber 1                                 719150          2762A-6         A-0015               1-18GHz        1685      I            12/7/2020
_
         Preamps /Couplers Attenuators / Filters                      Range             MN                Mfr                 SN          Asset Cat Calibration Due
                           2311 PA                                   1-1000MHz        PAM-103    COM-POWER                  441174        2311      II       10/29/2019
_
                          Antennas                                    Range             MN                Mfr                 SN          Asset Cat Calibration Due
                        Red-Black Bilog                             30-2000MHz          JB1            Sunol              A091604-2       1106      I            4/26/2021
_
             Meteorological Meters/Chambers                                             MN                Mfr                 SN          Asset Cat Calibration Due
               Weather Clock (Pressure Only)                                           BA928    Oregon Scientific          C3166-1        831       I            5/15/2020
                         Asset #2658                                                  1235C97 Control Company             181683808       2658      I            4/3/2020
_
                            Cables                                    Range                               Mfr                                      Cat Calibration Due
                         Asset #2456                                9KHz-18GHz                     MegaPhase                                        II       10/31/2019
                         Asset #2464                                9KHz-18GHz                     MegaPhase                                        II       10/31/2019
                         Asset #2585                                9KHz-18GHz                     Pasternack                                       II           5/24/2020
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                             _____________________________________________________________
                  Bureau Veritas Consumer Products Services, Inc.
                  One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                       page 11 of 20


                     Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                     ______________________________________________________________________



Occupied Bandwidth 99%




99% OBW = 2.22kHz

Test Equipment Used

Rev. 7/30/2019
      Spectrum Analyzers / Receivers /Preselectors                 Range            MN               Mfr               SN      Asset    Cat   Calibration Due   Calibrated on
            Rental MXE EMI Receiver(1170725)                   20Hz-26.5GHz N9038A                 Agilent         MY51210151 1170725    I       5/30/2020        5/30/2019
                   FSV40 Signal Analyzer                        10Hz-40GHz        FSV40 ROHDE & SCHWARZ              101551     2200     I       10/1/2019        10/1/2018
_
            Meteorological Meters/Chambers                                          MN               Mfr               SN      Asset    Cat   Calibration Due   Calibrated on
                Temp/Humidity Chamber #18                                        EPX-2H            Espec             137664     1645     I        1/2/2020        1/2/2019
_
                            Cables                                 Range                             Mfr                                Cat   Calibration Due   Calibrated on
                         Asset #2595                            9KHz-40GHz                         Carlisle                     2595     II      3/13/2020        3/13/2019
_
                          Antennas                                 Range            MN               Mfr               SN      Asset    Cat   Calibration Due   Calibrated on
                 2615 Active Loop Antenna                       9KHz-30MHz         6502            EMCO               2049      2615     I      10/30/2019       10/30/2018
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                              _____________________________________________________________
                    Bureau Veritas Consumer Products Services, Inc.
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                     page 12 of 20


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


Conducted Emissions

Bureau Veritas Consumer Product Services Inc.                                                                          Work Order # - T1639
Conducted Emissions per CISPR 16-2-1                                                                                   EUT Power Input - PoE
Peak Detector Data                                                                                                     Test Site - CEMI-2
Notes:                                                                                                                 Conditions: - 22.5°C; 48.8%RH; 1009mBar
EUTBLE9118K: Line                                                                                                      Test Engineer - AV
EUT Mode of Operation: PoE



Data Taken at 03:59:54 PM, Monday, August 05, 2019

                                                                                                      QP Lim:
                                                             Correction          Adjusted Pk      Mains_FCC&CISP         Margin to the       Pk to QP Limit    Worst Margin
   Frequency                          Raw Pk Reading           Factor             Amplitude        R_QP_Class_B            QP Limit              Results        (QP Limit)
              (MHz)                        (dBµV)                (dB)                (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
              0.151                         39.7                20.1                 59.9                65.9                  -6.1                 PASS
              0.179                         36.4                20.3                 56.7                64.5                  -7.8                 PASS
              0.242                         34.8                20.2                 55.1                 62                    -7                  PASS
              0.628                         27.1                20.2                 47.3                 56                   -8.7                 PASS
              0.734                         27.7                19.9                 47.7                 56                   -8.3                 PASS
     10.568                                  39                 20.5                 59.5                 60                   -0.5                 PASS            -0.5
Bureau Veritas Consumer Product Services Inc.                                                                          Work Order # - T1639
Conducted    Emissions
        Bureau               per CISPR
                  Veritas Consumer            16-2-1,
                                          Product       CISPRInc.
                                                    Services    Average Detector                                       EUT Power     Input - PoE
                                                                                                                             Peak Scan Data                                            Work Orde
Final Average Detector Data                                                                                            Test Site  - CEMI-2
                                                                                                                             Top Peaks                                                 EUT Powe
        Conducted Emissions per CISPR 16-2-1                                                                                                                                           Test Site -
Notes:                                                                                                                 Conditions:    - 22.5°C;
                                                                                                                             Quasi-Peak           48.8%RH; 1009mBar
                                                                                                                                        Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                       Conditions
EUTBLE9118K:     LineMeasured Data
        Peak Detector                                                                                                        Average Limit: Mains_FCC&CISPR_Avg_Class_B
                                                                                                                       Test Engineer - AV                                              Test Engin
        Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                                                    Marginal Level
EUT Mode    of Operation:
        Adjusted  Amplitude = Raw PoE Reading + RF Cable + Attenuator + Preselector + Limiter                  - Transducer.
                             TE Used: 3m OATS, MXE 1168255, CEMI_02, 64, None, None, 1732




Data Taken
      90
           at 03:59:54 PM, Monday, August 05, 2019

                                                                                                      Av Lim:
                        80                Raw Avg            Correction         Adjusted Avg      Mains_FCC&CISP                                                 Worst Avg
   Frequency                              Reading              Factor            Amplitude        R_Avg_Class_B           Avg Margin             Avg Results      Margin
              (MHz)                        (dBµV)                (dB)                (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
                        70
              0.157                         15.2                20.2                 35.4                55.6                  -20.2                PASS
              0.165                         15.2                20.1                 35.3                55.2                  -19.9                PASS
                        60
              0.236                         18.6                20.2                 38.8                52.2                  -13.4                PASS
    Amplitude: (dBµV)




              0.628                         25.2                20.2                 45.4                 46                   -0.6                 PASS            -0.6
                        50
              0.732                         24.6                19.9                 44.6                 46                   -1.4                 PASS
              13.56                         21.8                20.5                 42.3                 50                   -7.7                 PASS
                        40

                             Bureau Veritas Consumer Product Services Inc.
                                                                                                                                Quick Average Scan                                     Work Orde
                        30                                                                                                                                                             EUT Powe
                                                                                                                                Final Average Measurements
                             Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                                                                                              Test Site -
                                                                                                                                Quasi-Peak Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                       Conditions
                                                                                                                                Average Limit: Mains_FCC&CISPR_Avg_Class_B
                        20 Final Average Detector Measured Data                                                                                                                        Test Engin
                             Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                               Marginal Level
                             Adjusted Amplitude = Raw Reading + RF Cable + Attenuator + Preselector + Limiter - Transducer.
                             TE Used: 3m OATS, MXE 1168255, CEMI_02, 64, None, None, 1732
                        10


                                             _____________________________________________________________
                         0
                        90         Bureau Veritas Consumer Products Services, Inc.
                         150K                                                              1M                                                                                                10M
                                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAXFrequency
                                                                                                                 (978) 486-8828
                                                                                                                          (Hz)
                                                                                                                                                                       page 13 of 20
                                                                                                     EUTBLE9118K: Line
                        80                                                                           EUT Mode of Operation: PoE


                             Last Data Update 03:49:54 PM, Monday, August 05, 2019
                        70


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


Bureau Veritas Consumer Product Services Inc.                                                                        Work Order # - T1639
Conducted Emissions per CISPR 16-2-1                                                                                 EUT Power Input - PoE
Peak Detector Data                                                                                                   Test Site - CEMI-2
Notes:                                                                                                               Conditions: - 22.5°C; 48.8%RH; 1009mBar
EUT:BLE9118K Neutral                                                                                                 Test Engineer - AV
EUT Mode of Operation: PoE



Data Taken at 04:10:05 PM, Monday, August 05, 2019

                                                                                                    QP Lim:
                                                            Correction         Adjusted Pk      Mains_FCC&CISP         Margin to the         Pk to QP Limit   Worst Margin
   Frequency                         Raw Pk Reading           Factor            Amplitude        R_QP_Class_B            QP Limit                Results       (QP Limit)
              (MHz)                       (dBµV)                (dB)               (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
              0.158                         33.2               20.2                53.4                65.6                  -12.2                   PASS
              0.269                         28.8               20.2                 49                 61.2                  -12.2                   PASS
              0.419                         24.1               20.1                44.3                57.5                  -13.2                   PASS
              0.628                         26.5               20.2                46.7                 56                   -9.3                    PASS         -9.3
              0.733                         25.9               19.9                45.9                 56                   -10.1                   PASS
     13.559                                 28.5               20.5                 49                  60                   -11                     PASS
Bureau Veritas Consumer Product Services Inc.                                                                        Work Order # - T1639
Conducted    Emissions
        Bureau               per CISPR
                  Veritas Consumer            16-2-1,
                                          Product       CISPRInc.
                                                    Services    Average Detector                                     EUT Power     Input - PoE
                                                                                                                           Peak Scan Data                                            Work Orde
Final Average Detector Data                                                                                          Test Site  - CEMI-2
                                                                                                                           Top Peaks                                                 EUT Powe
        Conducted Emissions per CISPR 16-2-1                                                                                                                                         Test Site -
Notes:                                                                                                               Conditions:    - 22.5°C;
                                                                                                                           Quasi-Peak           48.8%RH; 1009mBar
                                                                                                                                      Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                     Conditions
EUT:BLE9118K     Neutral
        Peak Detector   Measured Data                                                                                      Average Limit: Mains_FCC&CISPR_Avg_Class_B
                                                                                                                     Test Engineer - AV                                              Test Engin
        Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                                                  Marginal Level
EUT Mode    of Operation:
        Adjusted  Amplitude = Raw PoE Reading + RF Cable + Attenuator + Preselector + Limiter                - Transducer.
                             TE Used: 3m OATS, MXE 1168255, CEMI_02, 64, None, None, 1732




Data Taken
      90
           at 04:10:05 PM, Monday, August 05, 2019

                                                                                                    Av Lim:
                        80               Raw Avg            Correction        Adjusted Avg      Mains_FCC&CISP                                                 Worst Avg
   Frequency                             Reading              Factor           Amplitude        R_Avg_Class_B           Avg Margin             Avg Results      Margin
              (MHz)                       (dBµV)                (dB)               (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
                        70
              0.628                         24.1               20.2                44.2                 46                   -1.8                    PASS         -1.8

                        60
    Amplitude: (dBµV)




                             Bureau Veritas Consumer Product Services Inc.
                                                                                                                              Quick Average Scan                                     Work Orde
                                                                                                                              Final Average Measurements                             EUT Powe
                        50 Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                                                                                              Test Site -
                                                                                                                              Quasi-Peak Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                     Conditions
                             Final Average Detector Measured Data                                                             Average Limit: Mains_FCC&CISPR_Avg_Class_B             Test Engin
                        40 Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                               Marginal Level
                           Adjusted Amplitude = Raw Reading + RF Cable + Attenuator + Preselector + Limiter - Transducer.
                           TE Used: 3m OATS, MXE 1168255, CEMI_02, 64, None, None, 1732

                        30


                        90
                        20


                        80
                        10


                        70
                         0
                         150K                                                                          1M                                                                                  10M
                                                                                                                                    Frequency (Hz)
                        60                  _____________________________________________________________
                                                                             EUTBLE9118K: Line
    Amplitude: (dBµV)




                                   Bureau Veritas Consumer Products Services, Inc. EUT Mode of Operation: PoE
                                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                      page 14 of 20
                        50 Last Data Update 03:49:54 PM, Monday, August 05, 2019



                        40


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


Bureau Veritas Consumer Product Services Inc.                                                                          Work Order # - T1639
Conducted Emissions per CISPR 16-2-1                                                                                   EUT Power Input - 24VDC
Peak Detector Data                                                                                                     Test Site - CEMI-2
Notes:                                                                                                                 Conditions: - 22.5°C; 48.8%RH; 1009mBar
EUT Line tested: Line Phase BLE9118K                                                                                   Test Engineer - AV
EUT Mode of Operation: 24 VDC



Data Taken at 01:40:39 PM, Monday, August 05, 2019

                                                                                                      QP Lim:
                                                             Correction          Adjusted Pk      Mains_FCC&CISP         Margin to the       Pk to QP Limit    Worst Margin
   Frequency                          Raw Pk Reading           Factor             Amplitude        R_QP_Class_B            QP Limit              Results        (QP Limit)
              (MHz)                        (dBµV)                (dB)                (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
              0.169                          39                 20.1                 59.1                 65                   -5.9                 PASS
              0.196                         36.2                20.2                 56.4                63.8                  -7.4                 PASS
              0.249                         33.8                20.3                 54.1                61.8                  -7.7                 PASS
              0.293                         30.8                20.2                  51                 60.5                  -9.4                 PASS
              0.351                         29.4                20.2                 49.6                58.9                  -9.4                 PASS
     13.559                                 34.7                20.5                 55.2                 60                   -4.8                 PASS            -4.8
Bureau Veritas Consumer Product Services Inc.                                                                          Work Order # - T1639
Conducted    Emissions
        Bureau               per CISPR
                  Veritas Consumer            16-2-1,
                                          Product       CISPRInc.
                                                    Services   Average Detector                                        EUT Power     Input -24VDC
                                                                                                                             Peak Scan Data                                            Work Orde
Final Average Detector Data                                                                                            Test Site  - CEMI-2
                                                                                                                             Top Peaks                                                 EUT Powe
        Conducted Emissions per CISPR 16-2-1                                                                                                                                           Test Site -
Notes:                                                                                                                 Conditions:    - 22.5°C;
                                                                                                                             Quasi-Peak           48.8%RH; 1009mBar
                                                                                                                                        Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                       Conditions
EUT LinePeak
         tested:     Line
              Detector       Phase
                        Measured   DataBLE9118K                                                                              Average Limit: Mains_FCC&CISPR_Avg_Class_B
                                                                                                                       Test Engineer - AV                                              Test Engin
        Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                                                    Marginal Level
EUT Mode    of Operation:
        Adjusted  Amplitude = Raw 24Reading
                                       VDC + RF Cable + Attenuator + Preselector + Limiter                     - Transducer.
                             TE Used: CEMI 2, MXE 1168255, CEMI_02, 64, None, None, 1732




Data Taken
      90
           at 01:40:39 PM, Monday, August 05, 2019

                                                                                                      Av Lim:
                        80                Raw Avg            Correction         Adjusted Avg      Mains_FCC&CISP                                                 Worst Avg
   Frequency                              Reading              Factor            Amplitude        R_Avg_Class_B           Avg Margin             Avg Results      Margin
              (MHz)                        (dBµV)                (dB)                (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
                        70
              0.153                         15.2                20.1                 35.3                55.8                  -20.6                PASS
                    0.16                    15.1                20.2                 35.3                55.5                  -20.2                PASS
                        60
              0.169                         15.1                20.1                 35.3                 55                   -19.8                PASS
    Amplitude: (dBµV)




              0.224                         13.4                20.2                 33.6                52.7                  -19                  PASS
                        50
              0.263                         13.6                20.2                 33.8                51.3                  -17.6                PASS
     13.564                                 20.8                20.5                 41.3                 50                   -8.7                 PASS            -8.7
                        40

                             Bureau Veritas Consumer Product Services Inc.
                                                                                                                                Quick Average Scan                                     Work Orde
                        30                                                                                                                                                             EUT Powe
                                                                                                                                Final Average Measurements
                             Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                                                                                              Test Site -
                                                                                                                                Quasi-Peak Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                       Conditions
                        20 Final Average Detector Measured Data                                                                 Average Limit: Mains_FCC&CISPR_Avg_Class_B             Test Engin
                             Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                               Marginal Level
                             Adjusted Amplitude = Raw Reading + RF Cable + Attenuator + Preselector + Limiter - Transducer.
                             TE Used: CEMI 2, MXE 1168255, CEMI_02, 64, None, None, 1732
                        10



                         0
                        90
                         150K                                                                            1M                                                                                  10M
                                                                                                                Frequency (Hz)
                                         _____________________________________________________________
                                                                                   EUT Line tested: Live Phase BLE9118K
                        80         Bureau Veritas Consumer Products Services, Inc. EUT Mode of Operation: 24 VDC
                                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                        page 15 of 20
                             Last Data Update 01:29:08 PM, Monday, August 05, 2019
                        70


                                    Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                                    ______________________________________________________________________


Bureau Veritas Consumer Product Services Inc.                                                                        Work Order # - T1639
Conducted Emissions per CISPR 16-2-1                                                                                 EUT Power Input - 24VDC
Peak Detector Data                                                                                                   Test Site - CEMI-2
Notes:                                                                                                               Conditions: - 22.5°C; 48.8%RH; 1009mBar
EUT: BLE9118K Neutral                                                                                                Test Engineer - AV
EUT Mode of Operation: 24V DC



Data Taken at 01:52:04 PM, Monday, August 05, 2019

                                                                                                    QP Lim:
                                                             Correction         Adjusted Pk     Mains_FCC&CISP         Margin to the         Pk to QP Limit   Worst Margin
   Frequency                         Raw Pk Reading            Factor            Amplitude       R_QP_Class_B            QP Limit                Results       (QP Limit)
              (MHz)                        (dBµV)               (dB)               (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
                    0.15                    34.4                20.2                54.6                66                   -11.4                   PASS
              0.184                         33.6                20.3                53.9               64.3                  -10.4                   PASS
              0.219                         32.4                20.2                52.6               62.9                  -10.3                   PASS
              0.272                         29.9                20.2                50.1               61.1                  -11                     PASS
              0.304                          28                 20.2                48.2               60.1                  -11.9                   PASS
     13.559                                 35.2                20.5                55.7                60                   -4.3                    PASS         -4.3
Bureau Veritas Consumer Product Services Inc.                                                                        Work Order # - T1639
Conducted    Emissions
        Bureau               per CISPR
                  Veritas Consumer            16-2-1,
                                          Product       CISPRInc.
                                                    Services   Average Detector                                      EUT Power     Input - 24VDC
                                                                                                                           Peak Scan Data                                            Work Orde
Final Average Detector Data                                                                                          Test Site  - CEMI-2
                                                                                                                           Top Peaks                                                 EUT Powe
        Conducted Emissions per CISPR 16-2-1                                                                                                                                         Test Site -
Notes:                                                                                                               Conditions:    - 22.5°C;
                                                                                                                           Quasi-Peak           48.8%RH; 1009mBar
                                                                                                                                      Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                     Conditions
EUT: BLE9118K     Neutral
        Peak Detector   Measured Data                                                                                      Average Limit: Mains_FCC&CISPR_Avg_Class_B
                                                                                                                     Test Engineer - AV                                              Test Engin
        Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                                                  Marginal Level
EUT Mode    of Operation:
        Adjusted  Amplitude = Raw 24V    DC + RF Cable + Attenuator + Preselector + Limiter
                                      Reading                                                                - Transducer.
                             TE Used: CEMI 2, MXE 1168255, CEMI_02, 64, None, None, 1733




Data Taken
      90
           at 01:52:04 PM, Monday, August 05, 2019

                                                                                                    Av Lim:
                        80                Raw Avg            Correction        Adjusted Avg     Mains_FCC&CISP                                                 Worst Avg
   Frequency                              Reading              Factor           Amplitude       R_Avg_Class_B           Avg Margin             Avg Results      Margin
              (MHz)                        (dBµV)               (dB)               (dBµV)             (dBµV)                 (dB)              (Pass/Fail)        (dB)
                        70
              13.56                         27.5                20.5                 48                 50                    -2                     PASS          -2

                        60
    Amplitude: (dBµV)




                             Bureau Veritas Consumer Product Services Inc.
                                                                                                                              Quick Average Scan                                     Work Orde
                                                                                                                              Final Average Measurements                             EUT Powe
                        50 Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                                                                                              Test Site -
                                                                                                                              Quasi-Peak Limit: Mains_FCC&CISPR_QP_Class_B
                                                                                                                                                                                     Conditions
                             Final Average Detector Measured Data                                                             Average Limit: Mains_FCC&CISPR_Avg_Class_B             Test Engin
                        40 Tile Version: 7.4.4.12, Profile Version 13 May 2019.                                               Marginal Level
                           Adjusted Amplitude = Raw Reading + RF Cable + Attenuator + Preselector + Limiter - Transducer.
                           TE Used: CEMI 2, MXE 1168255, CEMI_02, 64, None, None, 1733

                        30


                        90
                        20


                        80
                        10


                        70
                         0
                         150K                                                                          1M                                                                                  10M
                                                                                                                                    Frequency (Hz)
                        60                  _____________________________________________________________
                                                                             EUT: BLE9118K Neutral
    Amplitude: (dBµV)




                                   Bureau Veritas Consumer Products Services, Inc. EUT Mode of Operation: 24V DC
                                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                      page 16 of 20
                        50 Last Data Update 01:48:18 PM, Monday, August 05, 2019



                        40


                       Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                       ______________________________________________________________________


Test Equipment Used
Rev. 7/30/2019
     Spectrum Analyzers / Receivers /Preselectors                   Range               MN                 Mfr             SN       Asset    Cat   Calibration Due   Calibrated on
             Rental MXE EMI Receiver(1168255)                    20Hz-8.4GHz         N9038A              Agilent        MY53290009 1168255    I       8/23/2019        8/23/2018
_
                 LISNs/Measurement Probes                           Range               MN                 Mfr             SN       Asset    Cat   Calibration Due   Calibrated on
                       LISN Asset 1732                          150kHz-30MHz          LI-150A          Com-Power          201094    1732      I       3/19/2020        3/19/2019
                       LISN Asset 1733                          150kHz-30MHz          LI-150A          Com-Power          201095    1733      I       3/19/2020        3/19/2019
_
           Conducted Test Sites (Mains / Telco)                   FCC Code                             VCCI Code                             Cat   Calibration Due   Calibrated on
                            CEMI 2                                  719150                               A-0015                              III         NA              N/A
_
            Meteorological Meters/Chambers                                              MN                 Mfr             SN       Asset    Cat   Calibration Due   Calibrated on
                 Weather Clock (Pressure Only)                                        BA928         Oregon Scientific    C3166-1     831      I       5/15/2020        5/15/2018
                         Asset #2655                                                 1235C97        Control Company     181683829   2655      I       4/3/2020         4/3/2019
_
                            Cables                                  Range                                  Mfr                               Cat   Calibration Due   Calibrated on
                           CEMI-02                               9kHz - 2GHz                               C-S                                II      4/10/2020        4/10/2019
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                 _____________________________________________________________
                      Bureau Veritas Consumer Products Services, Inc.
                      One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                        page 17 of 20


                 Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                 ______________________________________________________________________



Measurement Uncertainty

The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note
that the uncertainty values are provided for informational purposes only and are not used in determining
the PASS/FAIL results.
                                  Measurement                               Expanded Uncertainty k=2   Maximum allowable uncertainty
                      Radiated Emissions (30-1000MHz)
                                    NIST                                             5.6dB                          N/A
                     CISPR [no table (i.e. floor standing)]                          4.6dB                     5.2dB (Ucispr)
                             CISPR[table present]                                    6.0dB
          Radiated Emissions (1-26.5GHz) [no table (i.e. floor standing)]            4.6dB                          N/A
                Radiated Emissions (1-26.5GHz) [table present]                       6.3dB                          N/A
                      Radiated Emissions (above 26.5GHz)                             4.9dB                          N/A

                          Magnetic Radiated Emissions                                5.6dB                          N/A
                              Conducted Emissions
                                     NIST                                            3.9dB                          N/A
                                    CISPR                                            3.6dB                     3.6dB (Ucispr)
                      Telco Conducted Emissions (Current)                            2.9dB                          N/A

                      Telco Conducted Emissions (Voltage)                            4.4dB                          N/A

                             Electrostatic Discharge                                 11.5%                          N/A

                      Radiated RF Immunity (Uniform Field)                           1.6dB                          N/A

                            Electrical Fast Transients                               23.1%                          N/A

                                      Surge                                          23.1%                          N/A

                             Conducted RF Immunity                                    3dB                           N/A

                               Magnetic Immunity                                     12.8%                          N/A

                               Dips and Interrupts                                    2.3V                          N/A

                                    Harmonics                                        3.5%                           N/A

                                      Flicker                                        3.5%                           N/A

                                                                                               -8
                          Radio frequency (@ 2.4GHz)                               3.23 x 10                      1 x 10-7

                              RF power, conducted                                    0.40dB                       0.75dB
    Maximum frequency deviation:
              Within 300Hz and 6kHz of audio frequency / Within 6kHz and            3.4%                           5%
               25kHz of audio frequency                                              0.3dB                          3dB
                             Adjacent channel power                                  1.9dB                          3dB

        Conducted spurious emission of transmitter, valid up to 12.75GHz             2.39dB                         3dB

                        Conducted emission of receivers                              1.3dB                          3dB

              Radiated emission of transmitter, valid up to 26.5GHz                  3.9dB                          6dB

               Radiated emission of transmitter, valid up to 80GHz                   3.3dB                          6dB

               Radiated emission of receiver, valid up to 26.5GHz                    3.9dB                          6dB

                Radiated emission of receiver, valid up to 80GHz                     3.3dB                          6dB

                                     Humidity                                        2.37%                          5%

                                  Temperature                                        0.7°C                         1.0°C

                                      Time                                           4.1%                          10%

                          RF Power Density, Conducted                                0.4dB                          3dB

                         DC and low frequency voltages                               1.3%                           3%

                              Voltage (AC, <10kHz)                                   1.3%                           2%

                                  Voltage (DC)                                       0.62%                          1%

    The above reflects a 95% confidence level



                           _____________________________________________________________
                Bureau Veritas Consumer Products Services, Inc.
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                           page 18 of 20


                Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                ______________________________________________________________________



Conditions Of Testing
[Bureau Veritas Consumer Products Services, Inc., a Massachusetts corporation], and/or its affiliates (collectively, the
"Company") will conduct, at the request of the Submitter (“Client”), the tests specified on the submitted Test Request Form or
equivalent in accordance with, and subject to, the following terms and conditions (collectively, “Conditions”):
1. All orders for tests are subject to acceptance by the Company, and no order will constitute a binding commitment of the
Company unless and until such order is accepted by it, as evidenced by the issuance of a written report (“Test Report”) by the
Company. The Test Report is issued solely by the Company, is intended for the exclusive use of Client and shall not be published,
used for advertising purposes, copied or replicated for distribution to any other person or entity or otherwise publicly disclosed
without the prior written consent of the Company. By submitting a request for services to the Company, Client consents to the
disclosure to accreditation bodies of those records of Client relevant to the accreditation body's assessment of the Company's
competence and compliance with relevant accreditation criteria. The Company shall not be liable for any loss or damage
whatsoever resulting from the failure of the Company to provide its services within any time period for completion estimated by the
Company. If Client anticipates using the Test Report in any legal proceeding, arbitration, dispute resolution forum or other
proceeding, it shall so notify the Company prior to submitting the Test Report in such proceeding. The Company has no obligation
to provide a fact or expert witness at such proceeding unless the Company agrees in advance to do so for a separate and additional
fee.
2. The Test Report will set forth the findings of the Company solely with respect to the test samples identified therein. Unless
specifically and expressly indicated in the Test Report, the results set forth in such Test Report are not intended to be indicative or
representative of the quality or characteristics of the lot from which a test sample is taken, and Client shall not rely upon the Test
Report as being so indicative or representative of the lot or of the tested product in general. The Test Report will reflect the findings
of the Company at the time of testing only, and the Company shall have no obligation to update the Test Report after its issuance.
The Test Report will set forth the results of the tests performed by the Company based upon the written information provided to the
Company. The Test Report will be based solely on the samples and written information submitted to the Company by Client, and the
Company shall not be obligated to conduct any independent investigation or inquiry with respect thereto.
3. The Company may, in its sole discretion, destroy samples which have been furnished to the Company for testing and which have
not been destroyed in the course of testing. The Company may delegate the performance of all or a portion of the services
contemplated hereunder to an affiliate, agent or subcontractor of the Company, and Client consents to such delegation.
4. These Conditions and the Test Report represent the entire understanding of the parties hereto with respect to the subject matter
hereof and of the Test Report, and no modification, variance or extrapolation with respect thereto shall be permitted without the prior
written consent of the Company.
5. The names, service marks, trademarks and copyrights of the Company and its affiliates, including the names “BUREAU
VERITAS,” “BUREAU VERITAS CONSUMER PRODUCTS SERVICES,” “BVCPS”, “MTL”, “ACTS”, “MTL-ACTS” and CURTIS-
STRAUS (collectively, the “Marks”) are and shall remain the sole property of the Company or its affiliates and shall not be used by
Client except solely to the extent that Client obtains the prior written approval of the Company and then only in the manner
prescribed by the Company. Client shall not contest the validity of the Marks or take any action that might impair the value or
goodwill associated with the Marks or the image or reputation of the Company or its affiliates.
6. Payment in full shall be due 30 days after the date of invoice. Interest shall be due on overdue amounts from the due date until
paid at an interest rate of 1.5% per month or, if less, the maximum rate permitted by law. The Company reserves the right, at any
time and from time to time, to revoke any credit extended to Client. Client shall reimburse the Company for any costs it incurs in
collecting past due amounts, including court costs and fees and expenses of attorneys and collection agencies. The Test Report
may not be used or relied upon by Client if and for so long as Client fails to pay when due any invoice issued by the Company or
any affiliate of it to Client or any affiliate or subsidiary of Client together with interest and penalties, if any, accrued thereon.
7. The Company disclaims any and all responsibility or liability arising out of or in connection with e-mail transmissions of such
information.
8. Client understands and agrees that the Company is neither an insurer nor a guarantor, that the Company does not take the
place of Client or any designer, manufacturer, agent, buyer, distributor or transportation or shipping company, and that the Company
disclaims all liability in such capacities. Client further understands that if it seeks assurance against loss or damage, it should obtain
appropriate insurance.
9. Client agrees that the Company, by providing the services, does not take the place of Client nor any third party, nor does the
Company release them from any of their obligations, nor does the Company otherwise assume, abridge, abrogate or undertake to
discharge any duty of any third party to Client or any duty of Client or any third party to any other third party, and Client will not
release any third party from its obligations and duties with respect to the tested goods.
10. Client shall, on a timely basis, (a) provide adequate instructions to the Company in order to enable the Company to perform
properly its services, (b) provide, or cause Client's suppliers and contractors to provide, the Company with all documents necessary
to enable the Company to perform its services, (c) furnish the Company with all relevant information regarding Client's intended use
and purposes of the tested goods, (d) advise the Company of essential dates and deadlines relevant to the tested goods and (e)
fully exercise all rights and remedies available to Client against third parties in respect of the tested goods.
11. The Company shall undertake due care and ordinary skill in the performance of its services to Client, and the Company shall
accept responsibility only were such skill has not been exercised and, even in such event, only to the extent of the limitation of
liability set forth herein.
12. If Client desires to assert a claim arising from or relating to (i) the performance, purported performance or non-performance of
any services by the Company or (ii) the sale, resale, manufacture, distribution or use of any tested goods, it must submit that claim
to the Company in a writing that sets forth with particularity the basis for such claim within 60 days from discovery of the potential
claim and not more than six months after the date of issuance of the Test Report to Client. Client waives any and all such claims
including, without limitation, claims that the Test Report is inaccurate, incomplete or misleading or that additional or different testing
is required, unless and then only to the extent that Client submits a written claim to the Company within both such time periods.


                       _____________________________________________________________
               Bureau Veritas Consumer Products Services, Inc.
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                      page 19 of 20


                Test Report for ASSA ABLOY Inc  Report No. ET1639-3  September 23, 2019
                ______________________________________________________________________

13. CLIENT SHALL, EXCEPT TO THE EXTENT OF COMPANY’S LIABILITY TO CLIENT HEREUNDER (WHICH IN NO EVENT
SHALL EXCEED THE LIMITATION OF LIABILITY HEREIN), HOLD HARMLESS AND INDEMNIFY THE COMPANY, ITS
AFFILIATES AND THEIR RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, AGENTS AND SUBCONTRACTORS AGAINST
ALL ACTUAL OR ALLEGED THIRD PARTY CLAIMS FOR LOSS, DAMAGE OR EXPENSE OF WHATSOEVER NATURE AND
HOWSOEVER ARISING FROM OR RELATING TO (i) THE PERFORMANCE, PURPORTED PERFORMANCE OR NON-
PERFORMANCE OF ANY SERVICES BY THE COMPANY OR (ii) THE SALE, RESALE, MANUFACTURE, DISTRIBUTION OR
USE OF ANY TESTED GOODS.
14. EXCEPT AS MAY OTHERWISE BE EXPRESSLY AGREED TO IN WRITING BY THE COMPANY AND NOTWITHSTANDING
ANY PROVISION TO THE CONTRARY CONTAINED HEREIN OR IN ANY TEST REPORT, NO WARRANTY OR GUARANTEE,
EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
OR USE, IS MADE.
15. (A) IN NO EVENT WHATSOEVER SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL,
INCIDENTAL, EXEMPLARY OR PUNITIVE DAMAGES IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE TEST
REPORT OR THE SERVICES PROVIDED BY THE COMPANY HEREUNDER, INCLUDING WITHOUT LIMITATION LOSS OF OR
DAMAGE TO PROPERTY; LOSS OF INCOME, PROFIT OR USE; OR ANY CLAIMS OR DEMANDS MADE AGAINST CLIENT OR
ANY OTHER PERSON BY ANY THIRD PARTY IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE SERVICES
PROVIDED BY THE COMPANY HEREUNDER.
    (B)NOTWITHSTANDING ANY PROVISION TO THE CONTRARY CONTAINED HEREIN, AND IN RECOGNITION OF THE
RELATIVE RISKS AND BENEFITS TO CLIENT AND THE COMPANY ASSOCIATED WITH THE TESTING SERVICES
CONTEMPLATED HEREBY, THE RISKS HAVE BEEN ALLOCATED SUCH THAT UNDER NO CIRCUMSTANCES
WHATSOEVER SHALL THE LIABILITY OF THE COMPANY TO CLIENT OR ANY THIRD PARTY IN RESPECT OF ANY CLAIM
FOR LOSS, DAMAGE OR EXPENSE, OF WHATSOEVER NATURE OR MAGNITUDE, AND HOWSOEVER ARISING, EXCEED
AN AMOUNT EQUAL TO FIVE (5) TIMES THE AMOUNT OF THE FEES PAID TO THE COMPANY FOR THE SPECIFIC
SERVICES WHICH GAVE RISE TO SUCH CLAIM OR U.S.$10,000, WHICHEVER IS THE LESSER AMOUNT.
16. The Company shall not be liable for any loss or damage resulting from any delay or failure in performance of its obligations
hereunder resulting directly or indirectly from any event of force majeure or any event outside the control of the Company. If any
such event occurs, the Company may immediately cancel or suspend its performance hereunder without incurring any liability
whatsoever to Client.
17. Company’s services, including these Conditions, shall be governed by, and construed in accordance with, the local laws of the
country where the Company performs the tests or, in the case of tests performed in the United States of America, the laws of
Massachusetts without regard to conflicts of laws principles. If any aspect(s) of these Conditions is found to be illegal or
unenforceable, the validity, legality and enforceability of all remaining aspects of these Conditions shall not in any way be affected or
impaired thereby. Any proceeding related to the subject matter hereof shall be brought, if at all, in the courts of the country where
the Company performs the tests or, in the case of tests performed in the United States of America, in the courts of Massachusetts.
Client waives the right to interpose any counterclaim or setoffs of any nature in any litigation arising hereunder.
          Rev.160009121(2)_#684340 v13CS




                       _____________________________________________________________
               Bureau Veritas Consumer Products Services, Inc.
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                     page 20 of 20



Document Created: 2019-10-04 07:19:24
Document Modified: 2019-10-04 07:19:24

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC