SIGFOX RTU – User guide version 1.0




SIGFOX RTU Module
By Adeunis

                                                                            User Guide Version 1.0



                                                     Document revision

   Version             Date              Author                            Comment

     1.0           20/07/2019             EMT                             Initial release




ADEUNIS
283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France
Tel. : +33 (0)4 76 92 07 77 - Fax : +33 (0)4 76 04 80 87
www.adeunis.com arf@adeunis.com


Information
Document information
Title                             SIGFOX RTU by Adeunis
Subtitle                          User Guide Version 1.0
Document type                     User Guide
Document status


This document applies to the following products

Name                                              Reference   Firmware version

RTU SIGFOX module                                 ARF8119A    V01.04.00




                                                                             Page 2 / 25


Table of contents
    DOCUMENT INFORMATION ..................................................................................................................................... 2
TABLE OF CONTENTS .................................................................................................................................. 3
    DISCLAIMER .................................................................................................................................................... 4
    TECHNICAL SUPPORT............................................................................................................................................ 5
    E NVIRONMENTAL RECOMMENDATIONS ................................................................................................................... 5
    WARNINGS ........................................................................................................................................................ 5
       COMPLIANCE TO FCC US/CAN ..................................................................................................................... 7
TECHNICAL SPECIFICATIONS ................................................................................................................ 10
       ARF8119A – RC2(US) / RC4(AUS/NZ) module ...................................................................................... 10
DEVICE OVERVIEW .................................................................................................................................... 11
    DEVICE DESCRIPTION .................................................................................................................................. 11
    RTU MODULE PINING ................................................................................................................................... 11
1      RTU MODULE HARDWARE INTERFACE ....................................................................................... 12
    1.1    HARDWARE INTERFACE .................................................................................................................... 12
      1.1.1    RTU interface ........................................................................................................................... 12
      1.1.2    RTU signal description ............................................................................................................. 13
    1.2    SERIAL INTERFACE PROTOCOL ......................................................................................................... 13
      1.2.1    Command format ...................................................................................................................... 13
      1.2.2    Implemented commands ........................................................................................................... 19
      1.2.3    Command execution time of RTU module ................................................................................ 19
2      RTU FEATURES MODE DESCRIPTION ........................................................................................... 20
    2.1    RTU STATE MACHINE ...................................................................................................................... 20
      2.1.1   State diagram ............................................................................................................................ 20
      2.1.2   Idle and Nominal mode ............................................................................................................. 20
      2.1.3   Command mode ........................................................................................................................ 20
    2.2    RTU APPLICATION INTERFACE IN COMMAND MODE ....................................................................... 21
      2.2.1   AT commands ........................................................................................................................... 21
    2.3    RTU APPLICATION INTERFACE IN NOMINAL MODE ......................................................................... 22
      2.3.1   Application commands: APPLICATION ➔ RTU .................................................................... 22
    SIGFOX TEST MODES .................................................................................................................................. 23
3      ANNEX 1 ................................................................................................................................................... 24




                                                                                                                                                    Page 3 / 25


DISCLAIMER
This document and the use of any information contained therein, is subject to the acceptance of the Adeunis RF
terms and conditions. They can be downloaded from www.adeunis.com.

Adeunis makes no warranties based on the accuracy or completeness of the contents of this document
and reserves the right to make changes to specifications and product descriptions at any time without
notice.

Adeunis reserves all rights to this document and the information contained herein.
Reproduction, use or disclosure to third parties without express permission is strictly
prohibited. Copyright © 2016, Adeunis. Adeunis is a registered trademark in the EU and
other countries.

All rights to this manual are the exclusive property of ADEUNIS . All rights reserved. Copying this manual (without
written permission from the owner) via printing, copying, recording or by any other means, translating this manual
(in full or partially) into any other language, including all programming languages, using any electrical, mechanical,
magnetic or optical devices, manually or any by other methods, is prohibited.

ADEUNIS reserves the right to change the technical specifications or functions of its products, or to cease
manufacturing any of its products, or to cease technical support for one of its products without notice in writing
and urges its customers to make sure that the information they have is valid.

ADEUNISF configuration software and programs are available free of charge in a non-modifiable version.
ADEUNISF can make no guarantees, including guarantees concerning suitability and applicability for a certain
type of application. Under no circumstances can the manufacturer, or the distributor of an ADEUNIS RF program,
be held liable for any damage caused by the use of the aforesaid program. Program names, as well as all
copyright relating to programs, are the exclusive property of ADEUNIS. Any transfer, granting of licences to a third
party, leasing, hire, transport, copying, editing, translation, modification into another programming language or
reverse engineering are prohibited without ADEUNIS’s prior written authorisation and consent.

ADEUNIS
283, rue Louis Néel
38920 Crolles France

Telephone +33 (0)4 76 92 07 77
Fax +33 (0)4 76 04 80 87




                                                                                                                     Page 4 / 25


Technical Support
Website
Our website contains much useful information: modules and stand-alone products information, user guides,
configuration software and technical documents which can be accessed 24 hours a day.

Email
If you have technical problems or cannot find the required information in the provided documents, contact our
Technical Support by email. Use our dedicated email address (arf@adeunis.com) rather than any personal email
address of our staff. This makes sure that your request is processed as soon as possible.

Helpful Information when Contacting Technical Support
When contacting Technical Support please have the following information ready:

          •         Product type (e.g. Wireless M-Bus),
          •         Firmware version (e.g. V3.03)
          •         Clear description of your question or the problem
          •         A short description of the application
          •         Your complete contact details




Environmental recommendations

All superfluous packaging materials have been eliminated. We have done everything possible to make it easy to
separate the packaging into three types of materials: cardboard (box), expanded polystyrene (filler material) and
polyethylene (packets, foam protective sheets). Your device is composed of materials that can be recycled and
reused if it is dismantled by a specialist company. Please observe local regulations concerning the manner in
which waste packaging material, used batteries and your obsolete equipment are disposed of.

Warnings
Valid for the following product:
ARF8119A



+AA       Read the instructions in the
          manual


          The safety of this product is only guaranteed when it is used in accordance with its
          purpose. Maintenance should only be carried out by qualified persons.

          Please note, do not install the equipment close to a heat source or in damp conditions.



          Warning: Do not open the product, risk of electric shock.



          Please note: for you own safety, you must ensure that equipment is switched off before carrying out any work on it.
          Please note: for your own safety, you must ensure that the equipment is switched off before carrying out any work on it.

          Please note: For your safety, the power supply circuit must be SELV (Safety Extra Low Voltage) and must be a limited power sources.

                                                                                                                Page 5 / 25


Recommendations regarding use
•   Before using the system, check that the power supply voltage shown in the user manual corresponds to
    your supply. If it doesn’t, please consult your supplier.
•   Place the device against a flat, firm and stable surface.
•   The device must be installed in a location that is sufficiently ventilated so that there is no risk of internal
    heating and it must not be covered with objects such as newspapers, cloths, curtains, etc.
•   The device’s aerial must be free and at least 10 cm away from any conducting material.
•   The device must never be exposed to heat sources such as heating equipment.
•   Do not place the device close to objects with naked flames such as lit candles, blowtorches, etc.
•   The device must not be exposed to aggressive chemical agents or solvents likely to damage the plastic or corrode the
    metal parts.
•   Install your device close to its DC power supply.




                                                                                                            Page 6 / 25


COMPLIANCE TO FCC US/CAN
                                                  Important regulary information
                                                         FCC ID : U3Z-ARF8119
• This device complies with part 15 of the FCC rules and Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1). this device may not cause Harmful interference, and (2).this device
must accept any interference received, including interference that may cause undesired operation ofthe device.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction, may cause harmful interference to radiocommunication. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures :
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
• CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY ADEUNIS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or
lower) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the
antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not superior than
necessary for successful communication.

WARNING !
FOR MOBILE DEVICE USAGE
.
This radiation element complies with FCC RF radiation exposure limits set forth for general population.
This radiation element must be installed to provide a separation distance of at least 20cm from all
persons and must not be co-located or operating in conjunction with any other antenna or
transmitter.

To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.”

This device has been designed to operate with the antennas listed below, and having a maximum gain of 6 dBi. Antennas
not included in this list or having a gain greater than 6 dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.”

MobileMark          PSKN3-925S          3 dBi gain                    dipole (see Annex1 for technical detail)
Adeunis                                 0 dBi+/-2dBgain               PCB Antenna (see Annex1 for technical detail)


                                          OEM Installation and Compliance Labeling
The ARF8119A module is labeled with its own FCC ID number, and, if the FCC ID is not visible when the module is installed
inside another device, then the outside of the device into which the module is installed must also display a label referring to
the enclosed transmitter module.

This exterior label can use wording such as the following:

“Contains Transmitter Module “Contains FCC ID: U3Z-ARF8119”

Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an
example of which must be included in the application for equipment authorization, or, must provide adequate instructions
along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the
application forequipment authorization.


                                                                                                                   Page 7 / 25


Ce dispositif est conforme aux règles de la FCC part 15 and à la norme CNR-210 d’Industrie Canada applicable aux
appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes : (1) le dispositif ne doit pas
produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible
de provoquer un fonctionnement indésirable.

Cet équipement a été testé et déclaré conforme aux limites d’un appareil numérique de classe B, conformément à la partie
15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles
dans une installation résidentielle. Cet équipement génère, utilise et peut émettre de l’énergie radiofréquence et, s’il n’est
pas installé et utilisé conformément aux instructions, peut causer des interférences nuisibles aux radiocommunications. Il est
cependant toujours possible que des interférences se produisent dans le cadre d’une installation particulière.
Si cet appareil produit des interférences nuisibles à la réception des programmes de radio et de télévision –détectables lors
de la mise hors tension ou en tension de l’appareil-l’utilisateur est encouragé à mettre en œuvre une ou plusieurs des
mesures suivantes pour remédier à ces interférences :
•Réorienter ou déplacer l’antenne de réception.
•Augmenter la distance entre l’équipement et le récepteur.
•Branchez le matériel à une sortie sur un circuit différent de celui auquel le récepteur est branché.
•Prendre conseil auprès du commerçant ou d’un technicien de radio/TV expérimenté.
Tout changement ou modification non expressément approuvé par la partie responsable des mesures de conformité peut
amener l’utilisateur à se voir interdire l’usage de l’appareil.
Cet appareil est limité à l’exploitation des fréquences autorisées Partie 15, et ne peut pas être configuré par des utilisateurs
finaux ou des installateurs professionnels à fonctionner en dehors des bandes autorisées.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un
type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de
brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.

ATTENTION !
POUR UTILISATION DE DISPOSITIF MOBILE
.
l’élément radio est conforme aux limites d'exposition aux rayonnements RF de la FCC établies pour la population générale.
l’élément radio doit être installé de manière à assurer une distance de séparation d'au moins 20 cm de tout
personnes et ne doivent pas être co-localisés ou fonctionner en conjonction avec toute autre antenne ou émetteur.

Pour réduire le brouillage radioélectrique potentiel causé aux autres utilisateurs, le type d’antenne et son gain doivent être
choisis de manière à ce que la puissance rayonnée isotropiquement équivalente (par exemple) ne soit pas supérieure à celle
autorisée pour une communication réussie. "

Cet appareil a été conçu pour fonctionner avec les antennes répertoriées ci-dessous et avec un gain maximal de 6 dBi. Les
antennes ne figurant pas dans cette liste ou ayant un gain supérieur à 6 dBi sont strictement interdites d'utilisation avec cet
appareil. L'impédance d'antenne requise est de 50 ohms. ”

MobileMark PSKN3-925S Dipole à gain de 3 dBi (voir détails en annexe1)
Antenne PCB Adeunis 0 dBi +/- 2dBgain (voir détails en annexe1)

I                                      installation OEM et étiquetage de conformité
Le module ARF8119A est étiqueté avec son propre numéro d’identification FCC. Si l’ID FCC n’est pas visible lorsque le
module est installé dans un autre périphérique, l’extérieur du périphérique sur lequel il est installé doit également afficher
une étiquette faisant référence au module.

Cette étiquette extérieure peut utiliser les libellés suivants:

“Contains Transmitter Module“ Contient le FCC ID: U3Z-ARF8119 ”

Toute formulation similaire exprimant le même sens peut être utilisée. Le bénéficiaire peut soit fournir une telle étiquette,
dont un exemple doit être inclus dans la demande d’autorisation d’équipement, soit fournir des instructions adéquates ainsi



                                                                                                                    Page 8 / 25


que le module qui explique cette exigence. Dans ce dernier cas, une copie de ces instructions doit être incluse dans la
demande d'autorisation d'équipement


Identification :
• FCC ID : U3Z-ARF8119


Product reference: USA/CANADA: ARF8119A




                                                                                                               Page 9 / 25


  Technical specifications


  ARF8119A – RC2(US) / RC4(AUS/NZ) module

Technical specifications
Communication                     SIGFOX protocol & SIGFOX DBPSK
Module configuration              Through AT commands
Radio data rate                   600bps
UART configuration                115.2 kbps/N/8/1
Frequency channels                ISM band 902-928MHz (US)- ISM band 915-928MHz(AUS/NZ)
RF output power                   23dBm (200mW)
Sensitivity                       down to -126dBm
Operating range (Line Of Sight)   Up to 15km
Operating temperature             -30°C / +70°C
Dimensions                        TBD
                                  FCC - Title 47 CFR
Standard compliance
                                  Part 15, RSS - 247 Issue 2




                                                                                          Page 10 / 25


Device Overview
Device Description
The SIGFOX RTU module by Adeunis is a SIGFOX Class 0 compliant device. It is NOT a point-to-point device
and cannot be operated in such a way. It is meant to be paired to an operated network.

The SIGFOX RTU module by ADEUNIS RF is a ready to use system, which provides connection to any
operated network using the SIGFOX protocol. It allows transmitting, receiving and instantly viewing the radio
frames on the used network.

RTU module pining

                                    ARF8119A
                                    RC2 / RC4




1 – GND                                                    21 – Uplink trigger
2 – GND                                                    22 – TP1
3 – ANTENA                                                 23 – Downlink trigger
4 – VCC                                                    24 – NC
5 – GND                                                    25 – NC
6 – NC                                                     26 – RTU READY
7 – /RESET                                                 27 – TP2
8 – NC                                                     28 – GND
9 – BOOT                                                   29 – TP3
10 – UART TX                                               30 – GND
11 – NC                                                    31 – GND
12 – UART RX                                               32 – GND
13 – NC                                                    33 – GND
14 – NC                                                    34 – GND
15 – NC                                                    35 – GND
16 – NC                                                    36 – GND
17 – NC                                                    37 – GND
18 – GND                                                   38 – SWCLK
19 – GND                                                   39 – SWDIO
20 – VCC

                                                                                               Page 11 / 25


1   RTU module hardware interface
1.1 Hardware interface

1.1.1   RTU interface

The radio module is based on ADEUNIS’s form factor and for SIGFOX module:




                                                                             Reset




                                                                                     TX monitor
                                                                                     RX monitor

                     RTU READY




                                          Figure 1: Radio module

               Pin                              Function                               description
                                                                                    Pulled up to VCC
                                                                                    Steady state = 1
               7                                 Reset
                                                                          1 = do nothing
                                                                          0 = reset module
               10                               UART TX                                     /
               12                               UART RX                                     /
                                                                                       READ ONLY
                                           TX-Uplink monitor
                                                                                    Steady state = 0
               21                  Signal that indicates if an UL is in
                                                                          1 = uplink in progress
                                                progress
                                                                          0 = no uplink in progress
                                                                                       READ ONLY
                                        RX – downlink monitor                       Steady state = 0
               23                  Signal that indicates if an DL is in   1 = Rx window opened
                                                progress                  0 = Rx window closed

                                                                                     READ ONLY
                                             RTU READY
                                                                                   Steady state = 1
               26                   Indicate if module is ready to
                                                                          1 = RTU ready
                                     receive commands on UART
                                                                          0 = RTU busy




                                                                                                Page 12 / 25


UART Configuration:
    • Data rate: 115.2 kbps,
    • Data size : 8 bits
    • Parity : None
    • Stop bit : 1 bit

In exploitation mode, UART is in charge of exchanging data to transmit (UPLINK), data to receive
(DOWNLINK), + some other internal data and traces (DEBUG, etc..)
Before exchanging UART frame, one or several WakeUp character could be emitted by the RTU module. This
number of wake up character is configurable (Register S2xx)

1.1.2    RTU signal description

       1.1.2.1 Reset signal
The reset signal allows a complete reset of the RTU module.

        1.1.2.1 RTU ready signal
This signal is used to indicate to the host microcontroller if RTU module is ready for reception of new command.
When the signal is low, data sent on the UART of the module are ignored. Each time a new command is transmitted
to the RTU, this signal goes low until the end of the command processing. After an Uplink command request, RTU
Ready stays low for the complete IoT cycle. In that case, the duration may be very long (many seconds).

       1.1.2.1 TX Uplink / RX Downlink signals
These two signals are signals frame activated at uplink (RF transmission) and downlink (RF reception) during IoT
cycle.

       1.1.2.1 UART Tx an UART Rx signals
These two signals allow UART communication to support the serial interface protocol. UART TX is an output of
the RTU module, UART Rx is an input.


1.2 Serial interface protocol

This protocol will be used on exchnge from apllication to RTU module and vice&versa.

1.2.1    Command format

Frame format little endian ➔ LSByte first

    1.2.1.1 Command
[WKUP] / SOF / LENGTH / CMD / [OPTIONS] / [DATAS] / [CRC]

WKUP: wakeup characters (optional)
     • N bytes '0xFF'
SOF: Start Of Frame: 2 bytes = 0x01FF (LSB First)
LENGTH: indicates size of frame including CMD, OPTIONS and DATAS, excluding CRC
     • 1 byte: (0x01 to 0xFF) = f(CMD)
CMD: Command
     • 1 octet
OPTIONS: depends on CMD (optional)
DATAS: depends on CMD (optional)
CRC: 4 bytes depends on CMD (optional)

        1.2.1.2 Acknowledge - Command answer



                                                                                                  Page 13 / 25


Acknowledge is always sent after receiving an application command ➔ Application commands:
APPLICATION ( RTU
Acknowledge is always expected after transmitting an application firmware upgrade command ➔ F4 / AF1 /
AF2 – Application µc firmware upgrade

[WKUP] / SOF / LENGTH / CMD / ACK / [DATA] / [CRC]

WKUP: wakeup characters (optional)
     • N bytes '0xFF'
SOF: Start Of Frame: 2 bytes = 0x01FF (LSB First)
LENGTH: following frame bytes number: 1 bytes = 0x02 to 0xFF
CMD: 1 byte: 0xFF if unknown command else received CMD
ACK: Acknowledge: 1 byte
               o 0x06 ➔ ACK
               o 0x15 ➔ NACK
DATA: [OPTIONNEL] only if ACK
CRC: 4 bytes depends on CMD (optional)


Command Uplink
Initiate a Uplink.

SOF / LENGTH / CMD / OPTIONS / DATA


CMD : Command
    • 0x04

OPTIONS
    • SIGFOX OPTIONS ➔ CTRL/TEMP
         o CTRL
                 ▪ Bit 0 ➔ bidir cycle if 1
                 ▪ Bit 1 ➔ frame OOB
                 ▪ Bit<3 :2> ➔ Nb of transmission (0 : valeur du registre, 1 à 3 : Nb of transmission
         o TEMP : Temperature expressed in tenths of degrees, signed in addition to 2 (2 octets – LSB
            First)


Command : Vbat Application
To inform the module about the supply voltage of the application.
SOF / LENGTH / CMD / Vbat

LENGTH : 0x03

CMD : Command
    • 0x05

VBAT : Application battery voltage in mV - 2 octets, LSB First

Command : Vbat Module RTU
Lets you know the supply voltage of the module.
SOF / LENGTH / CMD / Vbat

LENGTH : 0x01



CMD : Command
    • 0x06


                                                                                            Page 14 / 25


Answer :
    • ACK ➔ SOF / 0x03 / 0x06 / 0x06 / VBAT (mV, 2 octets LSB First)
    • NACK ➔ SOF / 0x02 / 0x06 / 0x15




Command ATReg Read
Allows you to read AT registers

SOF/ LENGTH / CMD / DATA

LENGTH : 0x03 (1 register) à 0x7F (63 registers)

CMD : Command
    • 0xFC

DATA: [REG1][REG2]….. [REG63]
    • [REGx]: n° du registre à lire, 2 octets (LSB First)

Answer :
    • ACK ➔ SOF / 0x06 / 0xFC / 0x06 / [REG1_VAL][REG2_VAL]…..[REG63_VAL]
    • NACK ➔ SOF / 0x02 / 0xFC / 0x15 / N°_REG

REGx_VAL: register value : 4 octets (LSB First)
N°_REG:
    • 0 if problem on the format of the frame: Length error, number of data (except CMD) % 2 !=0
    • 1 to 63 register index in the DATA field that caused the NACK
    •
Command ATReg Write
Allows writing AT registers

SOF/ LENGTH / CMD / DATA

LENGTH : 0x07 (1 register) à 0xFD (42 registers)

CMD : Command
    • 0xFD

DATA: [REG1][VALUE1] [REG2][VALUE2]….. [REG42][VALUE42],
    • [REGx]: number of the register to modify, 2 octets (LSB First)
    • [VALUEx]: value of the register to modify, 4 octets (LSB First)

Anwser :
    • ACK ➔ SOF / 0x06 / 0xFD / 0x06
    • NACK ➔ SOF / 0x02 / 0xFD / 0x15 / N°_REG

N°_REG:
    • 0 if problem on the format of the frame: Length error, number of data (except CMD) % 6 !=0
    • 1 a 42 register index in the DATA field that caused the NACK

Command Enter Command Mode
Enter command mode.
SOF/ LENGTH / CMD

LENGTH : 0x01

                                                                                           Page 15 / 25


CMD : Command
    • 0xFE

Anwser :
    • ACK ➔ SOF / 0x06 / 0xFE / 0x06 / ‘C’ / ‘M’ / 0x0D / 0x0A
    • NACK ➔ SOF / 0x02 / 0xFE / 0x15


    Emission orders or informational commands : RTU ➔ APPLICATION

These commands inform the application about the behavior of the RTU module.
Command Downlink

SOF / LENGTH / CMD / OPTIONS / DATA

LENGTH: length bytes to follow in bytes - always 8 for SIGFOX

CMD : Command
    • 0x00

OPTIONS
    • SIGFOX : OPTIONS ➔ RXWIN/Freq/ RSSI
         o RXWIN : fenêtre de réception durant laquelle les données ont été reçues
                ▪ 0x00 ➔ RX1
         o Freq : fréquence exprimée en Hz (4 octets – LSB First)
         o RSSI : niveau de réception de la trame de downlink (1 octet / signé)

DATA : downlink




                                                                                     Page 16 / 25


Command Encapsulation trace

Necessary encapsulation of the trace frames so that the application can redirect them to external UART / USB
SOF / LENGTH / CMD / TRACE_DATA

LENGTH : lenght TRACE_DATA + 1 octets

CMD : Command
    • 0x01

TRACE_DATA :

1.2.1.2.1 Command Uplink Cfg

Sent before each Uplink broadcast.

SOF / LENGTH / CMD / OPTIONS
LENGTH: 0x0C (sigfox)

CMD : Command
    • 0x02

OPTIONS
    • SIFGFOX : OPTIONS ➔ FREQ / BAND / TXPOWER / TXTIMEONAIR / SEQ /ULNUM
        o FREQ : frequency expressed in Hz (4 octets – LSB First)
        o BAND : frequency band (1 octet)
        o TXPOWER: transmission power in dBm (1 octet)
        o TXTIMEONAIR: transmission time of the frame expressed in ms (2 octets – LSB First)
        o SEQ : Sequence number (2 octets), LSB First
        o ULNUM : Up Link Number (1 byte) (1 = First date UL, 2 = Second date UL, 3 = third date UL,
           0 = OOB UL)

Command Power Fail

Sent in the event of a power failure, the supply voltage is lower than the minimum voltage (AT register S260),
once the command has been sent, the module automatically switches to STOP mode.
SOF / LENGTH / CMD

LENGTH: 0x01

CMD : Command
    • 0x03

Command RxWindowOpening

       This command is issued when a reception window is opened
SOF / LENGTH / CMD / OPTION

LENGTH: 0x02

CMD : Command
    • 0x05

SIGFOX: OPTIONS ➔ RX_SLOT
             o RX_SLOT :
                   ▪ 0x00 ➔ Rx slot 1
             o Rx FREQ : frequency expressed in Hz (4 octets – LSB First)




                                                                                                   Page 17 / 25


Command Init Done

This command is issued as soon as the module is initialized.
SOF / LENGTH / CMD

LENGTH: 0x01

CMD : Command
    • 0xFE




                                                               Page 18 / 25


1.2.2     Implemented commands

   Command code            Description              Type             Acknowledgement          CRC
                          Application to RTU Commands (Application command)
          0x00         Reset RTU module            Sigfox                  Yes                No
          0x01         Start RTU module            Sigfox                  Yes                No
          0x02         Stop RTU module             Sigfox                  Yes                No
          0x04           Uplink request            Sigfox                  Yes                No
          0x05         Application power           Sigfox                  Yes                No
                         supply voltage
          0x06        RTU module power             Sigfox                  Yes                No
                         supply voltage
          0xFE          Enter command              Sigfox                  Yes                No
                              mode
        0x09-0xFD              RFU
                           RTU to Application Commands (Indication command)
          0x00         Downlink message            Sigfox                  No                 No
          0x01           Trace message             Sigfox                  No                 No
          0x02        Uplink configuration         Sigfox                  No                 No
                            message
          0x03        Power fail message           Sigfox                  No                 No
          0x05         Reception window            Sigfox                  No                 No
                             opening
          0x07        New Cycle Allowed            Sigfox                  No                 No
        0x08-0xFC              RFU
          0xFE              Init Done              Sigfox                  No                 No
          0xFF                 RFU


1.2.3     Command execution time of RTU module

This chapter is only for APPLICATION module command sent to RTU module with Acknowledgment
mechanism.
The command execution time will be indicated through pin RTU_READY maintained in low state position
during the time of command execution. This time depends on the command to execute.




                                                                                           Page 19 / 25


2    RTU features mode description
2.1 RTU State Machine

2.1.1   State diagram


                                      Reset



                                                       Idle mode
                                                            -
                                                       Waiting for a
                                                        start from
                                                           host




                                              Start RTU         Stop RTU
                                              command           command



                                                       Nominal
                                                        mode
             Enter Command mode                             -
                   command



                                 Enter Command mode                        ATO command
                                       command



                                                       Comman
                                                       d mode
                                                          -
                                                       Configuration
                                                         & Test
                                                        command




                                           Figure 9: RTU state diagram

2.1.2   Idle and Nominal mode
At powerup or after a reset or the module enter idle mode. To allow IoT communication, the host controller must
send the Start RTU command (command code 0x01). In these states, the module reaches ultra low power
consumption while there is not command processing. The module is automatically wakeup by the char received
on its UART and returns to standby mode after the processing.

2.1.3   Command mode
Command mode is the configuration and test command state of the RTU module. Command mode may be
entered from Idle mode or Nominal mode by sending the Enter Command Mode command (command code
0xFE). In this mode, the RTU is not standby so there is no power saving while the module stays in this state. The
command format is based on AT style command which is an ASCII oriented format.

                                                                                                   Page 20 / 25


2.2 RTU Application interface in Command mode

2.2.1     AT commands
        2.2.1.1 Change command execution level
This command must be called before using ATT10 or ATT24 command to change the execution level of the
module.

Command format:
‘ATT63 ROOT’<CR>
Command answer:
‘O’<CR><LF> for OK if command succeeds, ‘E’<CR><LF> for error if command is rejected

       2.2.1.2 RF carrier command
This command places the RF in carrier wave mode.

Command format:
‘ATT10’<CR>
Command answer:
‘O’<CR><LF> for OK if command succeeds, ‘E’<CR><LF> for error if command is rejected

This test is exited on reception of an <ESC> char on UART. The module response is ‘O’<CR><LF> on <ESC>
reception.

     RF carrier command

This command places the RF in modulated carrier mode.

Command format:
‘ATT14’<CR>
Command answer:
‘O’<CR><LF> for OK if command succeeds, ‘E’<CR><LF> for error if command is rejected

This test is exited on reception of an <ESC> char on UART. The module response is ‘O’<CR><LF> on <ESC>
reception.


       2.2.1.3 RF reception command
This command places the RF in reception mode.

Command format:
‘ATT24’<CR>
Command answer:
‘O’<CR><LF> for OK if command succeeds, ‘E’<CR><LF> for error if command is rejected.

This test is exited on reception of an <ESC> char on UART. The module response is ‘O’<CR><LF> on <ESC>
reception.
Char received during this mode (which may correspond to RF data) must be discarded by the host controller.

       2.2.1.4 Exit command mode command
This command places the RF in reception mode.

Command format:
‘ATO’<CR>
Command answer:
‘O’<CR><LF> for OK if command succeeds, ‘E’<CR><LF> for error if command is rejected.

The module backs to Idle mode. The AT command interpreter is stopped and the module gets its lowest power
consumption.

                                                                                              Page 21 / 25


2.3 RTU Application interface in Nominal mode
This feature allows application to transmit/receive data from IOT network.
RTU module provides run time information to application.

2.3.1    Application commands: APPLICATION ➔ RTU

        2.3.1.1 Reset command

Reset RTU module

SOF/ LENGTH / CMD

LENGTH: 0x01
CMD: 0x00


        2.3.1.2 Start command

Allows to start up RTU module if power supply level is OK

SOF/ LENGTH / CMD

LENGTH: 0x01
CMD: 0x01

Expected answer:
     • ACK ➔ SOF / 0x03 / 0x01 / 0x06 / POWERFAIL (1 octet)
             o POWERFAIL != 0 ➔ POWER FAIL, power supply voltage is less than minimum power
                 supply voltage AT register 260 + 200 mV, le module repasse de lui-même en mode STOP (low
                 power)
             o POWERFAIL = 0 ➔ POWER GOOD, le module passe en mode START
     •    NACK ➔ SOF / 0x02 / 0x01 / 0x15

        2.3.1.3 Stop command

Stop module.

SOF/ LENGTH / CMD

LENGTH: 0x01
CMD: 0x02




                                                                                            Page 22 / 25


SIGFOX test modes
SIGFOX library has embedded test modes with the following format:

           Command                                      Description                             Comment
                                  Mode : test to execute
 AT$TM=<mode>,<loop><CR>
                                  Loop : number of test iterations to execute

Specific PRIVATE keys & IDs are used for P1 verification:

    -     ID = 0xFEDCBA98
    -     KEY = 0x0123456789ABCDEF0123456789ABCDEF

Private and public keys can be switched through register 202.

  Value
   of                      Test                                           Description
  mode
                                                 Send only BPSK with Synchro Bit + Synchro frame + PN
     0         SFX_TEST_MODE_TX_BPSK
                                                 sequence : no hopping centered on the TX_frequency
                                                 with full protocol with internal SIGFOX key : send all SIGFOX
     1      SFX_TEST_MODE_TX_PROTOCOL
                                                 protocol frames available with hopping
                                                 with full protocol with SIGFOX key: send SIGFOX protocol
     2      SFX_TEST_MODE_RX_PROTOCOL
                                                 frames with initiate downlink flag = SFX_TRUE
                                                 RX mode with known pattern with SB + SF + Pattern on
                                                 RX_Frequency (internaly comparison with received frame <=>
     3         SFX_TEST_MODE_RX_GFSK             known pattern= AA AA B2 27 1F 20 41 84 32 68 C5 BA 53 AE
                                                 79 E7 F6
                                                 DD 9B)
                                                 Do uplink + downlink frame with SIGFOX key with specific
     4         SFX_TEST_MODE_RX_SENSI
                                                 timings
                                                 Do 1 uplink frame on each sigfox channel to measure
     5         SFX_TEST_MODE_TX_BPSK
                                                 frequency synthesis step

Other test modes are available:

SEE Ultra Narrow Band Transceiver Product requirements specifications for AT CMD document
from SIGFOX for more details on how to use these test modes

         Command                                    Description                                Comment

          AT$SB                                       Send bit

           AT$SF                                     Send frame

           AT$IF                                TX central frequency

          AT$DR                                 RX central frequency

          AT$CW                                     Carrier wave

          AT$TR                                Number of repetitions




                                                                                                 Page 23 / 25


3   Annex 1
Dipole Antenna




                 Page 24 / 25


PCB ANTENNA




Polarization : Vertical

Gain : 0dB +/-2dB

Realized Gain (gain + efficient): 0dB +/-2dB

Parametre S: