RF Exposure Info

FCC ID: U2M-ENH500

RF Exposure Info

Download: PDF
FCCID_1602017

                           RF EXPOSURE REPORT


                             REPORT NO.: SA111005C10
                              MODEL NO.: ENH500, ENH500EXT
                                  FCC ID: U2M-ENH500
                               RECEIVED: Oct. 5, 2011
                                 TESTED: Oct. 14 ~ 18, 2011
                                  ISSUED: Oct. 26, 2011




                      APPLICANT: Senao Networks, Inc.

                          ADDRESS: 3F, No. 529, Chung Cheng Rd., Hsintien, Taipei,
                                   Taiwan, R.O.C.




                          ISSUED BY: Bureau Veritas Consumer Products Services
                                     (H.K.) Ltd., Taoyuan Branch

                 LAB LOCATION: No. 47, 14th Ling, Chia Pau Vil., Lin Kou
                               Dist.,New Taipei City, Taiwan ( R.O.C. )




 This test report consists of 6 pages in total. It may be duplicated completely for legal use with the
 approval of the applicant. It should not be reproduced, except in full, without the written approval of
 our laboratory. The client should not use it to claim product certification, approval or endorsement by
 any government agency. The test results in the report only apply to the tested sample.




Report No.: SA111005C10                          1                                 Report Format Version 4.0.0


                                    TABLE OF CONTENTS

RELEASE CONTROL RECORD .................................................................................... 3
1.    CERTIFICATION.............................................................................................. 4
2.    RF EXPOSURE LIMIT ..................................................................................... 5
3.    MPE CALCULATION FORMULA ..................................................................... 5
4.    CLASSIFICATION............................................................................................ 5
5.    CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




Report No.: SA111005C10                               2                                   Report Format Version 4.0.0


                          RELEASE CONTROL RECORD
  ISSUE NO.               REASON FOR CHANGE         DATE ISSUED
  SA111005C10             Original release         Oct. 26, 2011




Report No.: SA111005C10                      3       Report Format Version 4.0.0


1. CERTIFICATION
             PRODUCT:          Wireless 802.11an Access Point
          BRAND NAME:          EnGenius
            MODEL NO.:         ENH500, ENH500EXT
            APPLICANT:         Senao Networks, Inc.
          TEST SAMPLE:         ENGINEERING SAMPLE
               TESTED:         Oct. 14 ~ 18, 2011
           STANDARDS:          FCC Part 2 (Section 2.1091)
                               FCC OET Bulletin 65, Supplement C (01-01)
                               IEEE C95.1


 The above equipment (model no.: ENH500) has been tested by Bureau Veritas
 Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance
 with the requirement of the above standards. The test record, data evaluation &
 Equipment Under Test (EUT) configurations represented herein are true and accurate
 accounts of the measurements of the sample’s EMC characteristics under the
 conditions specified in this report.




   PREPARED BY            :                                        ,   DATE:
                              ( Celia Chen / Senior Specialist )



   APPROVED BY            :                                        ,   DATE:
                                   ( Ken Liu / Manager )




Report No.: SA111005C10                           4                            Report Format Version 4.0.0


2. RF EXPOSURE LIMIT
LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
  FREQUENCY               ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY     AVERAGE TIME
  RANGE (MHz)             STRENGTH (V/m) STRENGTH (A/m)   (mW/cm2)          (minutes)
                LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
     300-1500                  …                 …         F/1500               30
   1500-100,000                …                 …           1.0                30

F = Frequency in MHz


3. MPE CALCULATION FORMULA
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


4. CLASSIFICATION
The antenna of this product, under normal use condition, is at least 20cm away from the
body of the user. So, this device is classified as Mobile Device.




Report No.: SA111005C10                      5                      Report Format Version 4.0.0


5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

 FREQUENCY                       ANTENNA                   POWER
                    MAX POWER                  DISTANCE                         LIMIT
    BAND                           GAIN                   DENSITY
                      (dBm)                       (cm)                        (mW/cm2)
    (MHz)                          (dBi)                  (mW/cm2)
   5180-5240              9.98     13             20       0.0395                1.00
   5745-5825              22.9     13             20       0.7740                1.00



 --- END ---




Report No.: SA111005C10                    6                        Report Format Version 4.0.0



Document Created: 2011-11-24 09:15:49
Document Modified: 2011-11-24 09:15:49

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC