T39706-00-02KJ - Attachment B - RF Exposure - revised

FCC ID: TXTWC18CV

RF Exposure Info

Download: PDF
FCCID_2984925

                                                     Attachment B
                                                    (RF Exposure evaluation)


                  Type / Model Name                 : WC18CV


                 Product Description                : Inductive battery charger system



                                Applicant           : Robert Bosch GmbH

                                  Address           : Postfach 10 01 56

                                                      70745 Leinfelden-Echterdingen; GERMANY


                          Manufacturer              : Robert Bosch GmbH

                                  Address           : Postfach 10 01 56

                                                      70745 Leinfelden-Echterdingen; GERMANY


                        Licence holder              : Robert Bosch GmbH

                                  Address           : Postfach 10 01 56

                                                      70745 Leinfelden-Echterdingen; GERMANY



                                                       according to


                                                                                                            10. May 2016
        Test Report No. :                          T39706-00-02KJ               ______________________________________________________________________________________________

                                                                                                                Date of issue




                                                           The test report merely corresponds to the test sample.
                                                           It is not permitted to copy extracts of these test results
                                                           without the written permission of the test laboratory.




CSA Group Bayern GmbH                                                                 File No. T39706-00-02KJ, page 1 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                                                                Rev. No. 4.0, 2015-04-17


                                                     FCC ID: TXTWC18CV

                                                   Contents
       1     TEST ST AND ARDS                                                                     3

       3     TEST CONDITIONS AND RESULTS                                                          4

       3.1     RF exposure requirements (H-Field)                                                 4
       3.2     RF exposure requirements (E-Field)                                                 7

       4     USED TEST EQUIPMENT AND ACCESSORIES                                               10




CSA Group Bayern GmbH                                            File No. T39706-00-02KJ, page 2 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                     Rev. No. 3.0, 2014-01-30


                                                        FCC ID: TXTWC18CV

1 TEST STANDARDS
The tests were performed according to following standards:


KDB 680106 D01 v02: 2013                           RF Exposure considerations for low power consumer wireless
                                                   power transfer applications




CSA Group Bayern GmbH                                                      File No. T39706-00-02KJ, page 3 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                 Rev. No. 3.0, 2014-01-30


                                                            FCC ID: TXTWC18CV

3 TEST CONDITIONS AND RESULTS
3.1      RF exposure requirements (H-Field)
For test instruments and accessories used see section 6 Part CPR 1.

3.1.1    Description of the test location

Test location:                A1
Test distance:                10 cm



3.1.2    Photo documentation of the test set-up




                                                       (Scale: 10 cm per square)



3.1.3    Used field probe
 Manufacture:                                  Type:                                  Frequency range:
 Narda Safety Test Solutions                   ELT-400 with                           1 Hz to 400 kHz
                                               100 cm2 B field probe




CSA Group Bayern GmbH                                                              File No. T39706-00-02KJ, page 4 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                         Rev. No. 3.0, 2014-01-30


                                                            FCC ID: TXTWC18CV

3.1.4 Applicable standard
According to KDB 680106 D01 v02, Section 3, 3):
For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should
be conducted assuming a user separation distance of 10 cm. E and H field strength measurements or numerical
modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the
primary/client pair, with the 10 cm measured from the center of the probe(s) to the edge of the device. Emissions
between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m
and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz.



3.1.5    Description of Measurement
The maximum magnetic field strength was measured radiated, 10cm surrounding the device. The EUT is measured
in TX continuous mode, modulated, under normal conditions. The exposure level tester was set in RMS detection
mode with max. hold function. Each measurement point (MP) was tested over 6 minutes.

         Tested opeartion mode:                charging mode
         Operation frequencies:                - TX at 141.6 kHz and 145.5 kHz - charging / transmitting frequency
                                               - TX at 124.3 kHz - resonant frequency detection (with battery present)
                                               - TX at 210.5 kHz - sync pulse transmission



3.1.6    Test result




CSA Group Bayern GmbH                                                            File No. T39706-00-02KJ, page 5 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                        Rev. No. 3.0, 2014-01-30


                                                       FCC ID: TXTWC18CV


                                      Magnetignetic   Conversion
                Measurement                                                Limit            Delta
                                          field           in to                             (dB)
                 Point (MP)                                             (A/m RMS)
                                       (µT RMS)       (A/m RMS)
                        1                0.901           0.721              1.63             -7.1
                        2                0.517           0.414              1.63            -11.9
                        3                0.730           0.584              1.63             -8.9
                        4                0.648           0.518              1.63            -10.0
                        5                1.508           1.206              1.63             -2.6
                        6                1.355           1.084              1.63             -3.5


The requirements are FULFILLED.

Remarks:            All measurements where performed in charging mode in the frequency range from 124.3 kHz to

                    210.5 kHz because this are the worst case conditions.




CSA Group Bayern GmbH                                                       File No. T39706-00-02KJ, page 6 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                    Rev. No. 3.0, 2014-01-30


                                                        FCC ID: TXTWC18CV

3.2      RF exposure requirements (E-Field)
For test instruments and accessories used see section 6 Part CPR 1.

3.2.1    Description of the test location

Test location:                A1
Test distance:                10 cm



3.2.2    Photo documentation of the test set-up




                                                   (Scale: 10 cm per square)




CSA Group Bayern GmbH                                                          File No. T39706-00-02KJ, page 7 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                   Rev. No. 3.0, 2014-01-30


                                                            FCC ID: TXTWC18CV

3.2.3    Used field probe
 Manufacture:                                  Type:                                 Frequency range:
 Narda Safety Test Solutions                   PMM EP-602                            5 kHz to 9.25 GHz



3.2.4 Applicable standard
According to KDB 680106 D01 v02, Section 3, 3):
For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should
be conducted assuming a user separation distance of 10 cm. E and H field strength measurements or numerical
modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the
primary/client pair, with the 10 cm measured from the center of the probe(s) to the edge of the device. Emissions
between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m
and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz.



3.2.5    Description of Measurement
The maximum electric field strength was measured radiated, 10cm surrounding the device. The EUT is measured in
TX continuous mode, modulated, under normal conditions. The exposure level tester was set in peak detection mode
with max. hold function. Each measurement point (MP) was tested over 6 minutes.

         Tested opeartion mode:                charging mode
         Operation frequencies:                - TX at 141.6 kHz and 145.5 kHz - charging / transmitting frequency
                                               - TX at 124.3 kHz - resonant frequency detection (with battery present)
                                               - TX at 210.5 kHz - sync pulse transmission



3.2.6    Test result




CSA Group Bayern GmbH                                                            File No. T39706-00-02KJ, page 8 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                         Rev. No. 3.0, 2014-01-30


                                                               FCC ID: TXTWC18CV


                           Measurement             Electric field     Limit             Delta
                            Point (MP)                (V/m)         (V/m PKI)           (dB)
                                   1                   14.7           614               -32.4
                                   2                   10.5           614               -35.3
                                   3                   12.8           614               -33.6
                                   4                    9.6           614               -36.1
                                   5                   19.2           614               -30.1
                                   6                   15.5           614               -32.0


The requirements are FULFILLED.

Remarks:            All measurements where performed in charging mode in the frequency range from 124.3 kHz to

                    210.5 kHz because this are the worst case conditions.




CSA Group Bayern GmbH                                                           File No. T39706-00-02KJ, page 9 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                    Rev. No. 3.0, 2014-01-30


                                                         FCC ID: TXTWC18CV

4 USED TEST EQUIPMENT AND ACCESSORIES
All test instruments used are calibrated and verified regularly. The calibration history is available on request.

   Test ID         Model Type                       Equipment No.     Next Calib.   Last Calib.   Next Verif.     Last Verif.

   CPR 1           Exposure Level Tester ELT-400    01-02/40-13-001   11/02/2016 11/02/2015
                   B-Field Probe 100 cm²            01-02/40-13-002   09/02/2016 09/02/2015
                   Isotrope Electric Field EP-602   02-02/50-15-069   22/07/2016 22/07/2015




CSA Group Bayern GmbH                                                       File No. T39706-00-02KJ, page 10 of 10
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                       Rev. No. 3.0, 2014-01-30



Document Created: 2019-07-14 23:33:02
Document Modified: 2019-07-14 23:33:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC