Test report 15B

FCC ID: TXTGSH27

Test Report

Download: PDF
FCCID_4331758

                                            TEST REPORT
                                          No.: 17-1-0172601T17a-C2



                                                            According to:
                                                         FCC Regulations
                                                        Part 15.109, Class B

                                                         ISED-Regulations
                                                         ICES-003, Issue 6




                                                                 for

                                      Robert Bosch Tool Corporation

                                                   MI2C001-001-US
                                  With integrated SARA-R410M LTE Cat-M1 Module

                                                     FCC ID: TXTGSH27
                                                     ISED: 909H-GSH27


                                                     Laboratory Accreditation




                                       accredited according to DIN EN ISO/IEC 17025

                                                        CETECOM GmbH
                                Laboratory Radio Communications & Electromagnetic Compatibility
                                            Im Teelbruch 116 • 45219 Essen • Germany
                                   Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                     E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                       Page 1 of 22
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 17-1-0172601T17a-C2, Page 2 of 22


Table of contents
1. SUMMARY OF TEST RESULTS................................................................................................................... 3
  1.1. RX mode, tests overview according FCC Part 15B and Canadian ISED (RSS) Standards .......................... 3
  1.2. Attestation ..................................................................................................................................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................ 4
  2.1. Identification of the testing laboratory .......................................................................................................... 4
  2.2. Test location ................................................................................................................................................. 4
  2.3. Organizational items ..................................................................................................................................... 4
  2.4. Applicant’s details ........................................................................................................................................ 4
  2.5. Customer’s details ........................................................................................................................................ 4
  2.6. Manufacturer’s details .................................................................................................................................. 4
3. EQUIPMENT UNDER TEST (EUT) .............................................................................................................. 5
  3.1. EUT: Type, S/N etc. and short descriptions used in this test report ............................................................. 5
  3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ............................................................... 5
  3.3. EUT set-ups .................................................................................................................................................. 5
  3.4. EUT operating modes ................................................................................................................................... 6
4. DESCRIPTION OF TEST SYSTEM SET-UP’S ........................................................................................... 7
  4.1. Test system set-up for AC power-line conducted emission measurements .................................................. 7
  4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz ............................................ 7
  4.3. Test system set-up for radiated electric field measurement above 1 GHz .................................................... 9
5. MEASUREMENTS ........................................................................................................................................ 10
  5.1. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz ......................................................... 11
  5.2. General Limit - Radiated emissions, above 1 GHz ..................................................................................... 12
  5.3. Measurement uncertainties ......................................................................................................................... 13
6. ABBREVIATIONS USED IN THIS REPORT ............................................................................................ 14
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES .................... 14
8. INSTRUMENTS AND ANCILLARY ........................................................................................................... 15
  8.1. Test software and firmware of equipment .................................................................................................. 15
  8.2. Legend ........................................................................................................................................................ 18
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ........................................................................ 18
10. MEASUREMENT DIAGRAMS .................................................................................................................. 19
  10.1. EMI-AC mains ......................................................................................................................................... 19
  10.2. Radiated emissions in the frequency range 30 to 1000MHz ..................................................................... 20
  10.3. Radiated emissions in the frequency range above 1000MHz ................................................................... 22



Table of annex                                                                                                                                         Total pages
Annex 1: Measurement diagrams (included in this report)                                                                                                               22
Annex 2: Internal photographs, separate document CETECOM_TR17_1_0172601T18a_C2_A2                                                                                       6
Annex 3: External photographs, separate document CETECOM_TR17_1_0172601T18a_C2_A3                                                                                       6
Annex 4: Test set-up photographs, separate document CETECOM_TR17_1_0172601T18a_C2_A4                                                                                    3



The listed attachments are an integral part of this report.




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 3 of 22



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests. Also we refer on special conditions which the applicant should
fulfill according §2.927 to §2.948, special focus regarding modification of the equipment and availability of sample
equipment for market surveillance tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a digital device with support of radiofrequency
technologies including UMTS/LTE. A typical operation mode was set-up as described in chapter 3.4 according applicants
instructions.

Following tests have been performed to show compliance with applicable FCC Part 15, Subpart B (Unintentional
Radiators) of the CFR 47 Rules, Edition 2017.


1.1. RX mode, tests overview according FCC Part 15B and Canadian ISED (RSS) Standards
    No. of                                                               References & Limits                                               EUT
                                                                                                                             EUT
   Diagram              Test case               Port                                                                                        op-          Result
                                                                                                                            set-up
    group                                                 FCC Standard     RSS Section             Test limit                              mode
                                                                                                  FCC 15.109
                        Receiver
                                             Cabinet +      §15.109                              class B limits
                                                                         ICES-003, Issue
        4                                  Interconnec       §15.33                                                            1             1               Passed
                         radiated                                              6
                                            ting cables      §15.35                            ICES-003: Class B;
                        emissions
                                                                                                  Table 2, 5, 7
Remark:


1.2. Attestation:
I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct to
my best knowledge and belief to Industry Canada standards. All requirements as shown in above table are met in accordance with enumerated
standards.



The current version of the Test Report CETECOM_TR17-1-0172601T17a-C2 replaces the Test Report CETECOM_
TR17-1-0172601T17a-C1 dated 2018-11-05. The replaced test report is herewith invalid.

                                                                                                                               Ninovic
                                                                                                                               Perez
                                                                                                                               2019.04.29
                                                                                                                                15:24:48 +
                                                                                                                               02'00'
......................................................                                                ....................................................
Dipl.-Ing. N. Jeß                                                                                                          Dipl.-Ing. N. Perez
Responsible for test section                                                                                    Responsible for test report




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 4 of 22


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                        CETECOM GmbH
Address:                                                             Im Teelbruch 116
                                                                     45219 Essen - Kettwig
                                                                     Germany
Responsible for testing laboratory:                                  Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                        see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Project leader:                                                      B.Sc. Al-Amin Hossain
Responsible for test report:                                         Dipl.-Ing. Ninovic Perez
Receipt of EUT:                                                      2018-04-09
Date(s) of test:                                                     2018-05-04 and 2018-05-07
Date of report:                                                      2019-04-29
           -----------------------------------------------------------------------------------------------------------------------------------------------------


2.4. Applicant’s details

Applicant’s name:                                                    Robert Bosch Tool Corporation
Address:                                                             1800 W, Central Road
                                                                     Mount Prospect
                                                                     IL, 60056 USA

Contact person:                                                      Mr. Gerard Pasciak

2.5. Customer’s details

Customer’s name:                                                     Rosenberger Hochfrequenztechnik GmbH & Co.KG
Address:                                                             Hauptstr.1
                                                                     83413, Fridolfing
                                                                     Germany
Contact person:                                                      Mr. Matthias Rappl

2.6. Manufacturer’s details

Manufacturer’s name:                                                 Robert Bosch Power Tools GmbH.
Address:                                                             70538,Stuttgart
                                                                     Germany

Contact person:                                                      Mr. Thomas Moser




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 5 of 22


3. Equipment under test (EUT)


3.1. EUT: Type, S/N etc. and short descriptions used in this test report

 Short
                                                                      S/N              HW                 SW
 descrip-            EUT                       Type
                                                                 serial number    hardware status    software status
 tion*)

 EUT A                                                            IMEI-No:
                                                                                  MI2C001-001-   Doberman-
              MI2C001-001-US              SARA-R410M            352753090048
   S04                                                                              US#200     intern-US-1.0.0
                                                                    834
*) EUT short description is used to simplify the identification of the EUT in this test report.



3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

    AE
                                                                      S/N              HW                 SW
   short     Auxiliary Equipment               Type
                                                                 serial number    hardware status    software status
 descrip-
  tion *)
  AE 1           EUT Battery            ABI-L18650-1S1P                --                 --                --
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.3. EUT set-ups
 EUT set-up
                       Combination of EUT and AE                                      Remarks
   no.*)

    set. 1                     EUT A + AE 1                                                    --
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 6 of 22

3.4. EUT operating modes

    EUT
                 Description of
  operating                                              Additional information
                operating modes
 mode no.*)

                                        - LTE Cat M1 active and IDLE Mode
                   Data
                                        - DUT is attached(IDLE) in CMW 500 Signal generator
    op. 1     Communication and
                                        - EUT Battery is connected
               GNSS receiving
                                        - EUT LED’s:.D501 blinking and D500 glowing
*) EUT operating mode no. is used to simplify the test report.




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 7 of 22


4. Description of test system set-up’s
4.1. Test system set-up for AC power-line conducted emission measurements


 Specification:             ANSI C63.4-2014 chapter 7, ANSI C63.10-2013 chapter 6.2

 General Description:       The radio frequency voltage conducted back into the AC power line in the frequency
                            range 150 kHz to 30 MHz has to be investigated. Compliance should be tested by
                            measuring the radio frequency voltage between each power line and ground at the
                            power terminals in the stated frequency range.
                            A 50 Ohm / 50 µH line impedance stabilization network (LISN) is used coupling the
                            interface to the measurement equipment. The EUT power input leads are connected
                            through the LISN to the AC-power source. The LISN enclosure is electrically
                            connected to the ground plane. The measuring instrument is connected to the coaxial
                            output of the LISN.
                            Tabletop devices were set-up on a 80 cm height above reference ground plane, floor
                            standing equipment 10 cm raised above ground plane. Measurements have been
                            performed on each phase line and neutral line of the devices AC-power lines. The
                            EUT was power supplied with 120 V/60 Hz. The EUT was tested in the defined
                            operating mode and installed (connected) to accessory equipment according the
                            general description of use given by the applicant.

 Schematic:




                            Only schematic view, we refer to figure 6, 7 and 8 of ANSI C63.4-2009 for more details.



 Testing method:            Exploratory, preliminary measure-                  Final testing for power phases and
                            ments as a first step, determines the              critical frequencies (Margin to AV- or QP
                            worst-case phase line (neutral or phase)           limit lower than 3 dB) as a second step
                            as well as the most critical operating             includes measurements with receivers
                            mode of the equipment. A complete                  detector set to Quasi-Peak and Average.
                            frequency-sweep with PK-Detector is
                            performed on each current-carrying
                            conductor.
 Formula:                   VC= VR + CL (1)                          VC = measured Voltage –corrected value
                            M= LT-VC (2)                             VR = Receiver reading
                                                                     CL = Cable loss
                                                                     M = Margin
                                                                     LT = Limit
                            Values are in dB, positive margin means value is below limit.




4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz


CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 8 of 22



 Specification:             ANSI C63.4-2014 chapter 8, ANSI C63.10-2013 chapter 6.5

 General Description:       Evaluating the field emissions have to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies. The tests are
                            performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                            regulatory commissions.

 Schematic:




 Testing method:            Exploratory, preliminary measurements                Final measurement on critical frequencies
                            The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                            on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                            device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                            turntable. By rotating the turntable (range 0° to    position, etc.
                            360°, step 90°) and the EUT itself either on 3-
                            orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical frequency
                            orthogonal axis (defined operational position of     is done to locate the frequency more precisely. After
                            EUT) the emission spectrum and it’s                  this step, for all identified critical frequencies, the
                            characteristics was recorded with an EMI-            maximum peak was determined.
                            receiver, broadband antenna and software.
                                                                                 Following parameters were varied: the turntable
                            Measurement antenna: horizontal and vertical,        angle continuously in the range 0 to 360 degree, the
                            heights: 1,0 m and 1,82 m as worst-case              EUT itself either over 3-orthogonal axis (not
                            determined by an exploratory emission                defined usage position) or 2-orthogonal axis
                            measurements. The results are documented in a        (defined usage position). The measurement antenna
                            diagram. Critical frequencies (low margin to         height between 1 m and 4 m.
                            limit) are saved within a table for further
                            investigations. If various operating modes are       On the determined worst-case position, a final
                            supported, further investigations are made to find   measurement with necessary bandwidth and
                            the worst-case of them. Also the interconnection     detector according standard has been carried out.
                            cables and equipment position were varied in
                            order to maximize the emissions.

 Formula:                   EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                      CL = Cable loss
                            M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                      EC = Electrical field – corrected value
                                                                      ER = Receiver reading
                                                                      GA = Gain of pre-amplifier (if used)
                                                                      LT = Limit
                                                                      M = Margin
                            All units are dB-units, positive margin means value is below limit.




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 9 of 22

4.3. Test system set-up for radiated electric field measurement above 1 GHz

 Specification:             ANSI C63.4-2014 chapter 8, ANSI C63.10-2013 chapter 6.6

 General Description:       Evaluating the field emissions have to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies. The tests are
                            performed in a CISPR 16-4 compliant fully anechoic room (FAR) recognized by
                            the regulatory commissions. The measurement distance was set to 3 meter for
                            frequencies up to 18 GHz and 2 meter above 18 GHz. A bicon-log or horn antenna
                            is used for frequency range 1 GHz to 40 GHz. Due to use of a fully anechoic room
                            the measurement antennas are set to fixed antenna height of 1.55 m and the site
                            validation criteria accord. CISPR 16-1-4:2010, Chapter 8.3 is fulfilled. The EUT is
                            aligned within 3 dB beamwidth of the measurement antenna, on big EUTs several
                            surface measurements are performed.

 Schematic:




 Testing method:            Exploratory, preliminary measurements                Final measurement on critical frequencies
                            The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                            on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                            device) of 1.55 m height which is placed on the      taining the EUT’s worst-case operation mode,
                            turntable. By rotating the turntable (range 0° to    cable position, etc.
                            360°, step 15°) and the EUT itself either on 3-
                            orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical
                            orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                            EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                            characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                            receiver, broadband antenna and software.
                            The measurements are performed in horizontal         Following parameters were varied: the turntable
                            and vertical polarization of the measurement         angle continuously in the range 0 to 360 degree,
                            antennas. The results are documented in a            the EUT itself either over 3-orthogonal axis (not
                            diagram. Critical frequencies (low margin to         defined usage position) or 2-orthogonal axis
                            limit) are saved within a table for further          (defined usage position). The measurement
                            investigations. If various operating modes are       antenna height is fixed to 1.55 m.
                            supported, further investigations are made to find
                            the worst-case of them. Also the interconnection     On the determined worst-case position, a final
                            cables and equipment position were varied in         measurement with necessary bandwidth and
                            order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                   EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                      ER = Receiver reading
                            M = LT - EC         (2)                   M = Margin
                                                                      LT = Limit
                                                                      AF = Antenna factor
                                                                      CL = Cable loss
                                                                      DF = Distance correction factor (if used)
                                                                      GA = Gain of pre-amplifier (if used)
                            All units are dB-units, positive margin means value is below limit.




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 10 of 22


5. Measurements
5.1. General Limit - Conducted emissions on AC-Power lines
5.0.1. Test location and equipment
test location    CETECOM Essen (Chapter 2.2.1)     Please see Chapter 2.2.2              Please see Chapter 2.2.3
 test site       333 EMI field  348 EMI cond.
 receiver        001 ESS           377 ESCS 30    489   ESU 40      620 ESU 26
 LISN            005 ESH2-Z5  007 ESH3-Z6         300   ESH3-Z5 & 50 used for AE       no LISN for AE
 signalling      392 MT8820A  436 CMU             547   CMU         594 CMW
 line voltage    230 V 50 Hz via public mains      060    120 V 60 Hz via PAS 5000



5.0.2. Requirements Un-Intentional EUT
           FCC               Part 15, Subpart B, §15.107
            IC               RSS-Gen Issue 4, Chapter 8.8, Table 3
          ANSI               C63.4-2014, § 5.2, 6, 7
               Frequency                    Conducted limit Class B                      Conducted limit Class A
                 [MHz]         QUASI-Peak [dBµV]          AVERAGE [dBµV]         QUASI-Peak [dBµV]      AVERAGE [dBµV]
    Limit      0.15 – 0.5             66 to 56*                 56 to 46*               79                        66
                 0.5 – 5                 56                         46                  73                        60
                 5 – 30                  60                         50                  73                        60
  Remark: * decreases with the logarithm of the frequency



5.0.3. Test condition and test set-up
Signal link to test system (if used):    air link  cable connection  none
EUT-grounding                            none  with power supply  additional connection
Equipment set up                         table top                        floor standing
                                        (40 cm distance to reference       EUT stands isolated on reference ground plane (floor)
                                        ground plane (wall)
Climatic conditions                     Temperature: (22±3°C)             Rel. humidity: (40±20)%
                                         9 – 150 kHz,            RBW = 200 Hz, Step = 61 Hz
                   Scan data             150 kHz – 30 MHz        RBW = 9 kHz,       Step = 4 kHz
 EMI-Receiver or                         other:
 Analyzer settings Scan-Mode            6 dB EMI-Receiver Mode
                   Pre-measurement      Peak detector, Repetitive-Scan, max-hold, sweep-time 50 µs per frequency point
                   Final measurement    Average & Quasi-peak detector at critical frequencies
General measurement procedures          Please see chapter “Test system set-up for AC power line conducted emissions measurements”



5.0.4. Measurement results
The results are presented below in summary form only. For more information please see the diagrams
  EUT                set-up no.:                   set-up 1
                   EUT
  Diagram                                           Power Additional (scan-) information or        Result
              operating mode      Used Detector
     No.                                              line              remarks
             no. or commend
                   EUT            Peak (pre-scan)
    1.01      operating mode  AV (final)           L1/ N                  --                      passed
                     1            QP   (final)




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 11 of 22

5.1. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.1.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)           Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA
 receiver           377 ESCS30     001 ESS                  489 ESU 40       620 ESU 26
 spectr. analys.    584 FSU        120 FSEM                 264 FSEK
 antenna            574 BTA-L      133 EMCO3115             302 BBHA9170  289 CBL 6141      030 HFH-Z2  477 GPS
 signaling          392 MT8820A  371 CBT32                  547 CMU          594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E            110 USB LWL  482 Filter Matrix
 DC power           456 EA 3013A  457 EA 3013A              459 EA 2032-50  268 EA- 3050    494 AG6632A  498 NGPE
 line voltage       via laptop                               060 120 V 60 Hz via PAS 5000


5.1.2. Requirements/Limits
                     FCC
                                                 Part 15 Subpart B, §15.109, class B
                                                 Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                                 C63.4-2014
                     ANSI
                                                 C63.10-2013
                                                                          Radiated emissions limits, 3 meters
                      Frequency [MHz]
                                                            QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                          30 - 88                                 100                                         40.0
     Limit
                          88 - 216                                150                                         43.5
                         216 - 960                                200                                         46.0
                         above 960                                500                                         54.0


5.1.3. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
 General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”

5.1.4. MEASUREMENT RESULTS

The results are presented below in summary form only. For more information please see diagrams.

Table of measurement results:
   Dia-                      Set-        OP-                                                 Used detector                 Result
             Frequency
   gram                       up         mode                      Remark
               range
    no.                      no.          no.
                                                                                           PK     AV      QP
             30 MHz –
  3.01a                     Set. 1       Op. 1             EUT_Position_laying                                          Passed
              1 GHz
             30 MHz –
  3.01b                     Set. 1       Op. 1            EUT_Position_standing                                         Passed
              1 GHz
Remark: --




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 12 of 22

5.2. General Limit - Radiated emissions, above 1 GHz
5.2.1. Test location and equipment FAR
 test site          441 EMI SAR          348   EMI cond.     443   EMI FAR     347 Radio.lab. 337 OATS                
 spectr. analys.    584 FSU              120   FSEM          264   FSEK        489 ESU 40                             
 antenna meas       574 BTA-L            289   CBL 6141      608   HL 562      549 HL025      302 BBHA9170             477 GPS
 antenna meas       123 HUF-Z2           132   HUF-Z3        030   HFH-Z2      376 BBHA9120E                           
 antenna subst      071 HUF-Z2           020   EMCO3115      063   LP 3146     303 BBHA9170                           
 multimeter         341 Fluke 112                                                                                     
 signaling          392 MT8820A          371   CBT32         547   CMU         594 CMW
 DCpower            086 LNG50-10         087   EA3013        354   NGPE 40  349 car battery 350 Car battery           
 line voltage       via laptop                                060   120 V 60 Hz via PAS 5000

5.2.2. Requirements/Limits
                                 Part 15 Subpart B, §15.109 class B
           FCC                   Part 15 Subpart C, §15.209 for frequencies defined in §15.205
                                 Part 15 Subpart C, §15.407(b)(1)(2)(3)(4)

                                 C63.4-2014
           ANSI
                                 C63.10-2013
                                                                                       Limits
        Frequency                            AV                            AV                    Peak                      Peak
          [MHz]                            [µV/m]                       [dBµV/m]                [µV/m]                  [dBµV/m] or
                                                                                                                        [dBm/MHz]
       above 1 GHz
    for frequencies as
    defined in §15.205
                                            500                            54.0                  5000                   74.0 dBµV/m
            or
    RSS-Gen., Issue 4,
     §8.10 - Table 6

5.2.3. Test condition and measurement test set-up
 Signal link to test system (if used):             air link      cable connection       none
 EUT-grounding                                     none          with power supply  additional connection
 Equipment set up                                  table top 1.5m height                 floor standing
 Climatic conditions                              Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan frequency range:                    1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer      Scan-Mode                            6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                            Peak and Average
              RBW/VBW                             1 MHz / 3 MHz
              Mode:                               Repetitive-Scan, max-hold
              Scan step                           400 kHz
              Sweep-Time                          Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
General measurement procedures                    Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”

5.2.4. Measurement Results

The results are presented below in summary form only. For more information please see diagrams.

                                   Set-             OP-                                    Used detector                    Result
 Dia-gram          Frequency
                                    up              mode               Remark
    no.              range
                                   no.               no.
                                                                                          PK     AV      QP

    4.01           1 - 18 GHz     Set. 1            Op. 1                  --                                           Passed

Remark: --




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 13 of 22

5.3. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate coverage factor
k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and it’s
contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                          Calculated uncertainty based on a
     RF-Measurement             Reference        Frequency range                                                        Remarks
                                                                              confidence level of 95%
 Conducted emissions                            9 kHz - 150 kHz                        4.0 dB
                             CISPR 16-2-1                                                                                  -
 (U CISPR)                                     150 kHz - 30 MHz                        3.6 dB
 Radiated emissions                             30 MHz - 1 GHz                         4.2 dB
                             CISPR 16-2-3                                                                               E-Field
 Enclosure                                      1 GHz - 18 GHz                         5.1 dB
 Disturbance power           CISPR 16-2-2      30 MHz - 300 MHz       -                                                    -
                                                                                                                   Substitution
 Power Output radiated              -         30 MHz - 4 GHz                           3.17 dB
                                                                                                                   method
                                                                       Cel-   Cel-
                                              Set-up No.                             BT1     W1     W2        --
                                                                        C1     C2
 Power Output conducted             -          9 kHz - 12.75 GHz       N/A    0.60    0.7 0.25      N/A       --           -
                                                12.75 - 26.5GHz        N/A    0.82     --    N/A    N/A       --
 Conducted emissions                -           9 kHz - 2.8 GHz        0.70   N/A    0.70 N/A       0.69      --    N/A - not
 on RF-port                                   2.8 GHz - 12.75GHz       1.48   N/A    1.51 N/A       1.43      --    applicable
                                              12.75 GHz - 18GHz        1.81   N/A    1.83 N/A       1.77      --
                                               18 GHz - 26.5GHz        1.83   N/A    1.85 N/A       1.79      --
 Power density                      -             1 – 2.8GHz                            1.40 dB                    --
                                                                              0.1272 ppm (Delta Marker)            Frequency
 Occupied bandwidth                 -             9 kHz - 4 GHz                                                    error
                                                                                       1.0 dB                      Power
                                    -                                         0.1272 ppm (Delta Marker)            Frequency
 Emission bandwidth                               9 kHz - 4 GHz                                                    error
                                    -                                            See above: 0.70 dB                Power
 Frequency stability                -           9 kHz - 20 GHz                      0.0636 ppm                           -
                                               150 kHz - 30 MHz                        5.0 dB                      Magnetic
 Radiated emissions                             30 MHz - 1 GHz                         4.2 dB                      field
                                    -
 Enclosure                                      1 GHz - 20 GHz                        3.17 dB                      E-field
                                                                                                                   Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 14 of 22


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         FCC, Federal Communications
      (MRA US-EU
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)                             Commission
          0003)
 348                 Mains Ports Conducted Interference Measurements                          Laboratory Division, USA
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487    R-20013      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550    G-20013      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348    C-20009      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-20006     Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 15 of 22


8. Instruments and Ancillary
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory equipment.


8.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053          Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140          Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355          Power Meter                               URV 5                    891310/027          Firm.= 1.31
365          10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
598          Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
607          Signal Generator                          SMR 20                   832033/011          V1.25
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670          Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689          Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 16 of 22



8.1.1. Single instruments and test systems
 Ref.-No.




                                                                                                                                 calibration
                                                                                                                                 Interval of



                                                                                                                                                   Remark
                                 Equipment                         Type                Serial-No.               Manufacturer                                    Cal
                                                                                                                                                                due
001         EMI Test Receiver                         ESS                      825132/017               Rohde & Schwarz          12 M          -            16.05.2018
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                  861741/005               Rohde & Schwarz          12 M          -            15.05.2018
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  892563/002               Rohde & Schwarz          12 M          -            17.05.2018
009         Power Meter (EMS-radiated)                NRV                      863056/017               Rohde & Schwarz          24 M          -            15.05.2019
016         Line Impedance Simulating Network         Op. 24-D                 B6366                    Spitzenberger+Spies      36 M          -            30.05.2019
021         Loop Antenna (H-Field)                    6502                     9206-2770                EMCO                     36 M          -            30.04.2018
030         Loop Antenna (H-field)                    HFH-Z2                   879604/026               Rohde & Schwarz          36 M          -            30.04.2018
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                  879581/18                Rohde & Schwarz          24 M          -            15.05.2019
057         relay-switch-unit (EMS system)            RSU                      494440/002               Rohde & Schwarz          pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                 B6363                    Spitzenberger+Spies      -             3
086         DC - power supply, 0 -10 A                LNG 50-10                -                        Heinzinger Electronic    pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S                -                        Elektro Automatik        pre-m         2
091         USB-LWL-Converter                         OLS-1                    007/2006                 Ing. Büro Scheiba        -             4
099         Passedive voltage probe                   ESH2-Z3                  299.7810.52              Rohde & Schwarz          36 M          -            30.04.2018
100         Passedive voltage probe                   Probe TK 9416            without                  Schwarzbeck              36 M          -            30.04.2018
110         USB-LWL-Converter                         OLS-1                    -                        Ing. Büro Scheiba        -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547                   BOCONSULT                36 M          -            30.05.2019
133         horn antenna 18 GHz (Meas 1)              3115                     9012-3629                EMCO                     36 M          1c           10.03.2020
134         horn antenna 18 GHz (Subst 2)             3115                     9005-3414                EMCO                     36 M          -            10.03.2020
136         adjustable dipole antenna (Dipole 1)      3121C-DB4                9105-0697                EMCO                     36 M          -            30.04.2018
140         Signal Generator                          SMHU                     831314/006               Rohde & Schwarz          24 M          -            30.05.2018
248         attenuator                                SMA 6dB 2W               -                        Radiall                  pre-m         2
249         attenuator                                SMA 10dB 10W             -                        Radiall                  pre-m         2
252         attenuator                                N 6dB 12W                -                        Radiall                  pre-m         2
256         attenuator                                SMA 3dB 2W               -                        Radiall                  pre-m         2
257         hybrid                                    4031C                    04491                    Narda                    pre-m         2
260         hybrid coupler                            4032C                    11342                    Narda                    pre-m         2
261         Thermal Power Sensor                      NRV-Z55                  825083/0008              Rohde & Schwarz          24 M          -            30.05.2018
262         Power Meter                               NRV-S                    825770/0010              Rohde & Schwarz          24 M          -            30.05.2018
263         Signal Generator                          SMP 04                   826190/0007              Rohde & Schwarz          36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04        840414/009               Rohde & Schwarz          24 M          -            30.05.2018
266         Peak Power Sensor                         NRV-Z31, Model 04        843383/016               Rohde & Schwarz          24 M          -            30.05.2018
267         notch filter GSM 850                      WRCA 800/960-6EEK        9                        Wainwright GmbH          pre-m         2
270         termination                               1418 N                   BB6935                   Weinschel                pre-m         2
271         termination                               1418 N                   BE6384                   Weinschel                pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                 BF6239                   Weinschel                pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                 BF9229                   Weinschel                pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W    BG0321                   Weinschel                pre-m         2
275         DC-Block                                  Model 7003 (N)           C5129                    Weinschel                pre-m         2
276         DC-Block                                  Model 7006 (SMA)         C7061                    Weinschel                pre-m         2
279         power divider                             1515 (SMA)               LH855                    Weinschel                pre-m         2
298         Univ. Radio Communication Tester          CMU 200                  832221/091               Rohde & Schwarz          pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                  892 239/020              Rohde & Schwarz          12 M          -            17.05.2018
301         attenuator (20 dB) 50W, 18GHz             47-20-33                 AW0272                   Lucas Weinschel          pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                 155                      Schwarzbeck              36 M          -            14.03.2020
303         horn antenna 40 GHz (Subst 1)             BBHA9170                 156                      Schwarzbeck              36 M          -            20.03.2020
331         Climatic Test Chamber -40/+180 Grad       HC 4055                  43146                    Heraeus Vötsch           24 M          -            30.10.2018
341         Digital Multimeter                        Fluke 112                81650455                 Fluke                    24 M          -            30.05.2018
342         Digital Multimeter                        Voltcraft M-4660A        IB 255466                Voltcraft                24 M          -            17.05.2019
347         laboratory site                           radio lab.               -                        -                        -             5
348         laboratory site                           EMI conducted            -                        -                        -             5
354         DC - Power Supply 40A                     NGPE 40/40               448                      Rohde & Schwarz          pre-m         2
355         Power Meter                               URV 5                    891310/027               Rohde & Schwarz          24 M          -            30.05.2018
357         power sensor                              NRV-Z1                   861761/002               Rohde & Schwarz          24 M          -            24.05.2019
371         Bluetooth Tester                          CBT32                    100153                   R&S                      36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  100535                   Rohde & Schwarz          12 M          -            17.05.2018
377         EMI Test Receiver                         ESCS 30                  100160                   Rohde & Schwarz          12 M          -            15.05.2018
392         Radio Communication Tester                MT8820A                  6K00000788               Anritsu                  12 M          -            18.05.2018
405         Thermo-/Hygrometer                        OPUS 10 THI              126.0604.0003.3.3.3.22   LUFFT Mess u.            24 M          -            30.03.2019
                                                                                                        Regeltechnik
431         Model 7405                                Near-Field Probe Set     9305-2457                EMCO                     -             4
436         Univ. Radio Communication Tester          CMU 200                  103083                   Rohde & Schwarz          12 M          -            24.05.2018
439         UltraLog-Antenna                          HL 562                   100248                   Rohde & Schwarz          36 M          -            10.03.2020
443         CTC-FAR-EMI-RSE                           System CTC-FAR-EMI-RSE   -                        ETS-Lindgren / CETECOM   12 M          5            30.09.2018
454         Oscilloscope                              HM 205-3                 9210 P 29661             Hameg                    -             4
456         DC-Power supply 0-5 A                     EA 3013 S                207810                   Elektro Automatik        pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50            910722                   Elektro Automatik        pre-m         2
463         Universal source                          HP3245A                  2831A03472               Agilent                  -             4
466         Digital Multimeter                        Fluke 112                89210157                 Fluke USA                24 M          -            30.05.2018



CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 17 of 22
 Ref.-No.




                                                                                                                                           calibration
                                                                                                                                           Interval of



                                                                                                                                                             Remark
                                 Equipment                          Type                    Serial-No.             Manufacturer                                           Cal
                                                                                                                                                                          due
467         Digital Multimeter                        Fluke 112                     89680306                 Fluke USA                     36 M          -            30.04.2018
468         Digital Multimeter                        Fluke 112                     90090455                 Fluke USA                     36 M          -            30.04.2018
477         ReRadiating GPS-System                    AS-47                         -                        Automotive Cons. Fink         -             3
480         power meter (Fula)                        NRVS                          838392/031               Rohde & Schwarz               24 M          -            16.05.2019
482         filter matrix                             Filter matrix SAR 1           -                        CETECOM (Brl)                 -             1d
487         System CTC NSA-Verification SAR-EMI       System EMI field (SAR) NSA    -                        ETS Lindgren / CETECOM        24 M          -            31.09.2018
489         EMI Test Receiver                         ESU40                         1000-30                  Rohde & Schwarz               12 M          -            18.05.2019
502         band reject filter                        WRCG 1709/1786-1699/1796-     SN 9                     Wainwright                    pre-m         2
503         band reject filter                        WRCG 824/849-814/859-         SN 5                     Wainwright                    pre-m         2
512         notch filter GSM 850                      WRCA 800/960-02/40-6EEK       SN 24                    Wainwrght                     12 M          1c           30.06.2018
517         relais switch matrix                      HF Relais Box Keithley        SE 04                    Keithley                      pre-m         2
523         Digital Multimeter                        L4411A                        MY46000154               Agilent                       24 M          -            18.05.2019
529         6 dB Broadband resistive power divider    Model 1515                    LH 855                   Weinschel                     pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                   LOT 9828                 -                             pre-m         2
546         Univ. Radio Communication Tester          CMU 200                       106436                   R&S                           12 M          -            30.03.2018
549         Log.Per-Antenna                           HL025                         1000060                  Rohde & Schwarz               36/12 M       -            31.07.2018
550         System CTC S-VSWR Verification SAR-EMI    System EMI Field SAR S-       -                        ETS Lindgren/CETECOM          24 M          -            31.07.2018
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                         980026L                  Frankonia                     36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                         100248                   Rohde & Schwarz               pre-m         -
597         Univ. Radio Communication Tester          CMU 200                       100347                   Rohde & Schwarz               pre-m         -
600         power meter                               NRVD (Reserve)                834501/018               Rohde & Schwarz               24 M          -            17.05.2019
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)              8435323/003              Rohde & Schwarz               24 M          -            15.05.2019
602         peak power sensor                         NRV-Z32 (Reserve)             835080                   Rohde & Schwarz               24 M          -
611         DC power supply                           E3632A                        KR 75305854              Agilent                       pre-m         2
612         DC power supply                           E3632A                        MY 40001321              Agilent                       pre-m         2
613         Attenuator                                R416120000 20dB 10W           Lot. 9828                Radiall                       pre-m         2
616         Digitalmultimeter                         Fluke 177                     88900339                 Fluke                         24 M          -            30.05.2018
617         Power Splitter/Combiner                   ZFSC-2-2-S+                   S F987001108             Mini Circuits                 -             2
618         Power Splitter/Combiner                   50PD-634                      600994                   JFW Industries USA            -             2
619         Power Splitter/Combiner                   50PD-634                      600995                   JFW Industries, USA           -             3
620         EMI Test Receiver                         ESU 26                        100362                   Rohde-Schwarz                 12 M          -            16.05.2018
621         Step Attenuator 0-139 dB                  RSP                           100017                   Rohde & Schwarz               pre-m         2
625         Generic Test Load USB                     Generic Test Load USB         -                        CETECOM                       -             2
627         data logger                               OPUS 1                        201.0999.9302.6.4.1.43   G. Lufft GmbH                 24 M          -            30.03.2019
634         Spectrum Analyzer                         FSM (HF-Unit)                 826188/010               Rohde & Schwarz               pre-m         2
637         High Speed HDMI with Ethernet 1m          HDMI cable with Ethernet 1m   -                        KogiLink                      -             2
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet      -                        Reichelt                      -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund            -                        Reichelt                      -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with     -                        PureLink                      -             2
642         Wideband Radio Communication Tester       CMW 500                       126089                   Rohde&Schwarz                 12 M          -            24.05.2018
644         Amplifierer                               ZX60-2534M+                   SN865701299              Mini-Circuits                 -             -
670         Univ. Radio Communication Tester          CMU 200                       106833                   Rohde & Schwarz               24 M          -            30.05.2018
671         DC-power supply 0-5 A                     EA-3013S                      -                        Elektro Automatik             pre-m         2
678         Power Meter                               NRP                           101638                   Rohde&Schwarz                 pre-m         -
683         Spectrum Analyzer                         FSU 26                        200571                   Rohde & Schwarz               12 M          -            17.05.2018
686         Field Analyzer                            EHP-200A                      160WX30702               Narda Safety Test Solutions   24 M          -            29.03.2019
687         Signal Generator                          SMF 100A                      102073                   Rohde&Schwarz                 12 M          -            17.05.2018
688         Pre Amp                                   JS-18004000-40-8P             1750117                  Miteq                         pre-m         -
690         Spectrum Analyzer                         FSU                           100302/026               Rohde&Schwarz                 12 M          -            16.05.2018
691         OSP120 Base Unit                          OSP120                        101183                   Rohde & Schwarz               12 M          -            22.05.2018
692         Bluetooth Tester                          CBT 32                        100236                   Rohde & Schwarz               36 M          -            29.05.2020
697         Power Splitter                            ZN4PD-642W-S+                 165001445                Mini-Circuits                 -             2
703         INNCO Antennen Mast                       MA 4010-KT080-XPET-ZSS3       MA4170-KT100-XPET-       INNCO                         pre-m         -
704         INNCON Controller                         CO 3000-4port                 CO3000/933/38410516/L    INNCO Systems GmBh            pre-m         -
711         Harmonic Mixer 90 GHz - 140GHz            RPG FS-Z140                   101004                   RPG                           12 M          -            22.02.2018
712         Harmonic Mixer 75 GHz - 110GHz            FS-Z110                       101468                   Rohde & Schwarz               12 M          -            22.02.2018
713         Harmonic Mixer, 50 GHz - 75GHz            FS-Z75                        101022                   Rohde & Schwarz               12 M          -            22.05.2018
714         Signal Analyzer 67GHz                     FSW67                         104023                   Rohde & Schwarz               24 M          -            03.03.2019
715         Harmonic Mixer, 140 GHz - 220GHz          FS-Z220                       101009                   RPG Radiometer Physics        12 M          -            03.08.2018
716         Harmonic Mixer 220 GHz to 325 GHZ         FS-Z325                       101005                   RPG Radiometer Physics        12 M          -            13.02.2018
747         Spectrum Analyzer                         FSU 26                        200152                   Rohde & Schwarz               12 M          -            18.05.2018
748         Pickett-Potter Horn Antenna               FH-PP 4060                    010001                   Radiometer Physiscs           -             -
749         Pickett-potter Horn Antenna               FH-PP 60-90                   010003                   Radiometer Physics            -             -
750         Pickett-Potter Horn Antenna               FH-PP 140-220                 010011                   Radiometer Physics            -             -




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 18 of 22

8.2. Legend
Note / remarks                      Calibrated during system calibration:
                          1a        System CTC-SAR-EMS (Ref.-No. 442)
                          1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                          1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                          1d        System CTC-SAR-EMI (Ref.-No . 441)
                          1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                          1f        System CTC-CTIA-OTA (Ref.-No . 420)
                          1g        System CTC-FAR-EMS (Ref.-No . 444)
                          2         Calibration or equipment check immediately before measurement
                          3         Regulatory maintained equipment for functional check or support purpose
                          4         calibration of this equipment
                                    Ancillary equipment   without has no effect
                                                                  calibration   onmechanical
                                                                              e.g. measuring equipment
                                                                                             result    or monitoring equipment
                          5         Test System


Interval of calibration   12 M      12 month
                          24 M      24 month
                          36 M      36 month
                          24/12 M   Calibration every 24 months, between this every 12 months internal validation
                          36/12 M   Calibration every 36 months, between this every 12 months internal validation
                          Pre-m     Check before starting the measurement
                          -         Without calibration




9. Versions of test reports (change history)

       Version            Applied changes                                                                                        Date of release
         V1               Initial release                                                                                         2018-08-21
         C1               Manufacturer changed,                                                                                   2018-11-05
         C2               Applicant and coversheet logo changed                                                                   2019-04-29




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 19 of 22


10. Measurement diagrams
10.1. EMI-AC mains
                                                                  1.01
Common Information
  Test Description:                                Conducted Voltage Measurement Class B
  Test Site & Location:                            Conducted Emission, CETECOM GmbH Essen
  Test Software:                                   R&S EMC32 v9.15
  Test Specification:                              FCC 15.107, FCC 15.207
  Operating Mode:                                  Op 1
  Measured on line:                                N/L1
  Diagram details:                                 Shows the peak values as a sum of measured ports in maxhold mode
  Environmental Conditions:                        Humidity: 40.5%rH; Temperature: 21°C
  Operator:                                        LKu

EUT Information
  Manufacturer:                                    Robert Bosch Power Tools GmbH
  EUT:                                             MI2C001-001-US
  HW version:                                      MI2C001-001-US #200
  SW version:                                      Doberman-intern-US-1.0.0
  Serial number:                                   IMEI-No: 352753090048834
  Power Supply:                                    120V AC
         Level in dBµV




Final_Result
   Frequency             QuasiP      CAvera      Limit
     (MHz)                 eak         ge       (dBµV)
                         (dBµV)      (dBµV)
      0.541563                 ---     32.13     46.00
      0.541563             39.70          ---    56.00
      0.544219                 ---     30.86     46.00
      0.544219             39.02          ---    56.00




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 20 of 22

10.2. Radiated emissions in the frequency range 30 to 1000MHz
10.2.1. Part 15B
                                                            3.01a_laying

  Test description:                                 Electric Field Strength Measurement
  Test site and distance:                           Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance
  Version of Testsoftware:                          EMC32 V9.25.0
  Test specification.:                              FCC 15.109 Class B; RSS-Gen. Issue 4
  Operator:                                         LKu
  Operating mode                                    Op 1
  Power during tests:                               120V
  Environmental Conditions:                         Humidity: 40.5%rH; Temperature: 21°C



EUT Information                                       Please see Diagram Number 1.01
        Level in dBµV/m




Final_Result
  Frequen                 QuasiPeak    Limit    Bandwidt    Heigh   Pol   Azimut    Corr
     cy                   (dBµV/m)    (dBµV/        h         t              h        .
   (MHz)                                m)        (kHz)     (cm)           (deg)    (dB)
  30.19000                    28.09     40.00     120.000   114.0   H       159.0    21.5
         0
  87.25000                     7.50     40.00     120.000   368.0   H       240.0     8.0
         0
  98.89000                     8.77     43.50     120.000   173.0   V        12.0     8.1
         0
  423.6300
                              23.66     46.00     120.000   348.0   V       168.0   19.1
        00
  432.7700
                              22.28     46.00     120.000   335.0   V       308.0   19.3
        00
  911.8000
                              31.71     46.00     120.000   162.0   H        88.0   27.3
        00
  943.8900
                              31.72     46.00     120.000   337.0   V       325.0   26.9
        00



CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 21 of 22


                                                           3.01b_standing

  Test description:                                   Electric Field Strength Measurement
  Test site and distance:                             Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance
  Version of Testsoftware:                            EMC32 V9.25.0
  Test specification.:                                FCC 15.109 Class B; RSS-Gen. Issue 4
  Operator:                                           LKu
  Operating mode:                                     Op 1
  Power during tests:                                 120V
  Environmental Conditions:                           Humidity: 40.5%rH; Temperature: 21°C


EUT Information                                         Please see Diagram Number 1.01
        Level in dBµV/m




Final_Result
  Frequency               QuasiP      Limit   Margi      Meas.   Bandwidt     Heigh   Pol    Azimut    Corr
    (MHz)                   eak     (dBµV/m     n        Time        h          t               h        .
                          (dBµV/        )     (dB)       (ms)      (kHz)      (cm)            (deg)    (dB)
                            m)
  408.920000                20.49     46.00   25.51     1000.0      120.000   169.0   V        206.0   18.5
  420.000000                21.57     46.00   24.43     1000.0      120.000   344.0   V         77.0   18.8
  432.300000                21.94     46.00   24.06     1000.0      120.000   347.0   V        246.0   19.3
  916.560000                31.52     46.00   14.48     1000.0      120.000   342.0   V        113.0   26.9
  946.480000                31.82     46.00   14.18     1000.0      120.000   176.0   V        181.0   27.1




CETECOM_TR17_1_0172601T17a_C2


Test Report 17-1-0172601T17a-C2, Page 22 of 22

10.3. Radiated emissions in the frequency range above 1000MHz
10.3.1. Part 15B
                                                        4.01

Common Information
  Test Description:                     Radiated field strength emission in 3m distance
  Test Site:                            CETECOM GmbH Essen
  Test Standard:                        FCC 15.109 Unintentional Radiator
  Antenna polarisation:                 horizontal/vertical
  Operation mode:                       Op 1
  Operator Name:                        RIs
  Environmental Conditions:             Humidity: 40.5%rH; Temperature: 21°C
  Comment:                              120V AC


EUT Information                           Please see Diagram Number 1.01
        Level in dBµV/m




Remarks:
Emission at 1,960000000GHz is from LTE_Signal Generator_CMW 500(downlink) which has not considered as Pass or
Fail



                                            End Of Test Report




CETECOM_TR17_1_0172601T17a_C2



Document Created: 2019-06-25 11:52:06
Document Modified: 2019-06-25 11:52:06

© 2024 FCC.report