MPE

FCC ID: TVU-SX682

RF Exposure Info

Download: PDF
FCCID_971231

CETECOM ICT Services GmbH
 Test report No.: 2-4917-01-02/08             Date: 2008-05-31     Page 79 of 107


RF Exposure / Safety

Calculation of Maximum Permissable Exposure (MPE)
based on Section 1.1307(b) Requirements

a) FCC limit is: 1mW/cm2

b) The Wimax CPE can be configured in one of three different setups:
       Setup 1: CPE with 9dBi internal antenna
       Setup 2: CPE with 9dBi external desktop antenna
       Setup 3: CPE with 18dBi external outdoor antenna

c) The power density produced by the EUT is:

                  Pt ⋅ Gt
       S peak =
                  4πR 2

                     Pt ⋅ Gt ⋅ dc
       S average =
                     4πR 2 ⋅ 100

       Pt – Transitted power 251mW (rms peak) (24dBm)
       Gt – Antenna gain dependant on setup
       R – Distance from transmitter
       Dc – duty cycle

d) The power density is:

                                    Setup 1    Setup 2                 Setup 3

 Pt - Power output                  24dBm      24dBm                   24dBm
 (rms peak) 24dBm                   251mW      251mW                   251mW
 Gt – Antenna gain                  9dBi       9dBi – 3dB cable loss   18dBi – 3dB cable loss
                                    8          4                       31,6
 Maximum duty cycle                 45%        45%                     45%
 R – Distance from antenna          20         20                      120
 (cm)
 Speak – peak power density         0,4        0,2                     0,04
 (mW/cm2)
 Saverage – average power           0,18       0,09                    0,018
 density (mW/cm2)


e) Saverage << 1mW/cm2



Document Created: 2008-07-15 15:06:59