RF Exposure Info

FCC ID: TVU-S455

RF Exposure Info

Download: PDF
FCCID_650009

CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken         Phone: +49 (0) 681 598-0            Fax: -9075
RSC-Laboratory                                        Phone: +49 (0) 681 598-0            Fax: -9075


Test report no.: 2-4189-01-03/05                      Date: 2006-02-08                 Page 78 of 90


4.30      RF Exposure

                                                RF EXPOSURE INFO
Environmental evaluation measurements of Maximum Permissible Exposure (MPE) to radio frequency (RF) radiation from
transmitting devices for compliance with the technical rules and regulations of the U.S. Federal Communications
Commission and Industry Canada.

Description of EUT
Model: UPCS Base Station S455

1) The probe was positioned on a table at a separation distance of 20 cm from the radiating antenna and at a
starting height of 5 cm to the center of the probe.
2) The table was positioned so that the initial start angle was 0 degrees.
3) The EUT was powered on and allowed sufficient time to stabilize. The EUT was operated at full power on a
desired frequency.
4) The analyzer and the field probe was set for maximum hold, and set on the appropriate power range.
5) The table was rotated 360 degrees and the maximum reading was obtained for that elevation.
6) The antennas were lifted and lowered at maximum value in the horizontal plane to find the maximum in vertical position.


Result:
The max measured MPE value on a distance of 20 cm is:                            0.23 mW/cm2 by measurement with the analyzer
                                                                                 0.26 mW/cm2 by measurement with the field probe


MPE System Specification:
-         Electromagnetic Radiation Field probe, PMM Model 8053
          Frequency Range: 1 MHz to 40 GHz
          Calibration date: 05/2005
-         Signal analyzer FSIQ26 from R&S
          Frequency range: 10 Hz to 26.5 GHz
          Calibration date: 02/2005




Limit:
         1mW/ cm2 is the reference level for general public exposure according to the OET Bulletin 65,
                                             Edition 97-01 Table 1.



Document Created: 2006-04-21 10:32:33