Test Report HAC

FCC ID: TVUE560H

Test Report

Download: PDF
FCCID_4161215

                                                  TEST REPORT
                                            Test Report No.: 1-6814/18-01-14



                 Testing Laboratory                                                Applicant
 CTC advanced GmbH                                               Gigaset Communications GmbH
 Untertürkheimer Straße 6 – 10                                   Frankenstr. 2
 66117 Saarbrücken/Germany                                       46395 Bocholt/GERMANY
 Phone:    + 49 681 5 98 - 0                                     Phone:    +49 2871 91-0
 Fax:      + 49 681 5 98 - 9075                                  Contact: Uwe Alt
 Internet: http://www.ctcadvanced.com                            e-mail:   uwe.alt@gigaset.com
 e-mail:   mail@ctcadvanced.com                                  Phone:    +49 287 191-2857
                                                                 Fax:      +49 287 191-62857
 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
                                                                                 Manufacturer
 Deutsche Akkreditierungsstelle GmbH (DAkkS)
 The accreditation is valid for the scope of testing             Gigaset Communications GmbH
 procedures as stated in the accreditation certificate with      Frankenstr. 2
 the registration number: D-PL-12076-01-01                       46395 Bocholt/GERMANY

 Area of Testing: Acoustics


                                                      Test standard/s
 FCC - Title 47 CFR Part 68      FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 68 -
                                 Requirements and Test Methods for Magnetic Output from Handset Telephones
                                 for Hearing Aid Coupling




                                                            Product
 Kind of product:      DECT Handset
 Product name:         Gigaset W570H




This test report is electronically signed and valid without handwritten signature. The public keys can be requested
at the test laboratory to verify the electronic signatures.

 Test report authorised:                                         Test performed:
                              cn=Oleg Fallmann, o=CTC advanced                          cn=Joerg Langer, o=CTC
                              GmbH, ou=FMN-161207,                                      advanced GmbH, ou=LAN-161024,
                              email=Oleg.Fallmann@ctcadvanced.                          email=joerg.langer@ctcadvanced.
                              com, c=DE                                                 com, c=DE
                              2018.11.09 12:21:44 +01'00'                               2018.11.09 11:30:47 +01'00'

 Oleg Fallmann                                                   Jörg Langer
 Radio Communications & EMC                                      Radio Communications & EMC


                   Test report no.: 1-6814/18-01-14



1      Table of contents


1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
3    Test standard/s ...............................................................................................................................................3
4    Test environment ............................................................................................................................................4
5    Test laboratories sub-contracted .................................................................................................................4
6    Test setup ........................................................................................................................................................5
7    Information about product.............................................................................................................................6
8    Summary of measurement results ...............................................................................................................7
9    Detailed Test Results .....................................................................................................................................8
10       Test equipment and ancillary equipment used for tests .....................................................................19
11       Observations ............................................................................................................................................20
Annex A          Photographs of the test set-up.......................................................................................................21
Annex B          Photographs of the EUT ..................................................................................................................23
Annex C          Document history ............................................................................................................................24
Annex D          Further information .........................................................................................................................24




© CTC advanced GmbH                                                                                                                                    Page 2 of 24


               Test report no.: 1-6814/18-01-14



2     General information

2.1   Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CTC advanced
GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with
regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CTC advanced GmbH.
The testing service provided by CTC advanced GmbH has been rendered under the current "General Terms and
Conditions for CTC advanced GmbH".
CTC advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or
incomplete product information provided by the customer.
Under no circumstances does the CTC advanced GmbH test report include any endorsement or warranty
regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CTC advanced GmbH test report include or imply any product or service
warranties from CTC advanced GmbH, including, without limitation, any implied warranties of merchantability,
fitness for purpose, or non-infringement, all of which are expressly disclaimed by CTC advanced GmbH.
All rights and remedies regarding vendor’s products and services for which CTC advanced GmbH has prepared
this test report shall be provided by the party offering such products or services and not by CTC advanced GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronical
signatures, the public keys can be requested at the testing laboratory.



2.2   Application details
Date of receipt of order:                2018-09-26
Date of receipt of test item:            2018-11-08
Start of test:                           2018-11-08
End of test:                             2018-11-26
Person(s) present during the test:       %



3     Test standard/s
 Test standard            Version          Test standard description

 FCC - Title 47 CFR                         FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part
 Part 68                                   68 - Requirements and Test Methods for Magnetic Output from
                                           Handset Telephones for Hearing Aid Coupling




 © CTC advanced GmbH                                                                                      Page 3 of 24


              Test report no.: 1-6814/18-01-14



4     Test environment
 Temperature:                                    18-28°C
 Relative humidity content:                      40-80%
 Atmospheric pressure:                           813-1063hPa
 Power supply:                                   230 V / 50 Hz


5     Test laboratories sub-contracted
---




 © CTC advanced GmbH                                             Page 4 of 24


                  Test report no.: 1-6814/18-01-14




6       Test setup

6.1     Used Artificial Ears
Test Head Type 1:


    Ear Type 1: IEC 60318


    Ear Type 3.2: IEC 60711 + Simplified Pinna Simulator (High Leakage)


    Ear Type 3.2: IEC 60711 + Simplified Pinna Simulator (Low Leakage)



HATS (Head and Torso Simulator):


    Ear Type 3.3: IEC 60711 + Pinna simulator (anatomically shaped)              

    Ear Type 3.4: IEC 60711 + Pinna simulator (simplified anatomically shaped)




6.2     Used Audio Codec(s)
Narrowband:


    G.711 a-law


    G.711 u-law                                                                  

    G.726


    G.729


Wideband:


    G.722


    G.729.1




 © CTC advanced GmbH                                                             Page 5 of 24


                Test report no.: 1-6814/18-01-14



7         Information about product

    Kind of product:           DECT Handset
    Test Item:                 Gigaset W570H
    Serial number:             FCC15 # No.8.1
    Hardware version:          1-6814_18-01-03.pdf
    Firmware version:          BL 81.022.00
    Operating mode:
    ---
    Additional information:

    ---




© CTC advanced GmbH                                  Page 6 of 24


                  Test report no.: 1-6814/18-01-14




8        Summary of measurement results

                   No deviations from the technical specifications were ascertained
                   There were deviations from the technical specifications ascertained




8.1      47 e-CFR Part 68 Requirements Table

                                                                          Reference
    No                             Test description                                         Selected     Verdict
                                                                       47 e-CFR Part 68

    1     Axial Field intensity                                       68.316 4.2                        PASS

    2     Radial Field intensity                                      68.316 4.3                        PASS

    3     Inducted Voltage Frequency Response                         68.316 4.4                        PASS

    4     Hearing Aid volume control                                  68.317                            PASS

          Total                                                                                         PASS



8.2      Status Overview

                                                                                                            Single
                          SMD                         Status            Single Value Description
                                                                                                            Value
68.316 4.2 Axial Field Intensity                       Ok      Level [dB(A/m)]. 0                             -15.24
68.316 4.3 Radial Field Intensity 0 Degree             Ok      Level [dB(A/m)]. 0                             -23.08
68.316 4.3 Radial Field Intensity 90 Degree            Ok      Level [dB(A/m)]. 0                             -24.54
68.316 4.3 Radial Field Intensity 180 Degree           Ok      Level [dB(A/m)]. 0                             -22.43
68.316 4.3 Radial Field Intensity 270 Degree           Ok      Level [dB(A/m)]. 0                             -23.12
68.316 4.4 Induced Frequency Response >= -
                                                       Ok      Max. Peak value [dB[V]]. 3328.1 Hz             -23.35
19 dB
68.316 4.4 Induced Frequency Response rel.                     Min. dist. to tolerance scheme [dB[V]].
                                                       Ok                                                          1.47
to 1kHz                                                        515.6 Hz
68.317 Volume Control unamplified                     Done     RLR [dB]                                        42.12
68.317 Volume Control maximum                         Done     RLR [dB]                                        24.33
68.317 Calculating maximum Gain                        Ok      Calculated Value                                17.79




© CTC advanced GmbH                                                                                      Page 7 of 24


                    Test report no.: 1-6814/18-01-14




9        Detailed Test Results


68.316 4.2 Axial Field Intensity .............................................................................................................................9
68.316 4.3 Radial Field Intensity 0 Degree ........................................................................................................10
68.316 4.3 Radial Field Intensity 90 Degree ......................................................................................................11
68.316 4.3 Radial Field Intensity 180 Degree ....................................................................................................12
68.316 4.3 Radial Field Intensity 270 Degree ....................................................................................................13
68.316 4.4 Induced Frequency Response >= -19 dB .......................................................................................14
68.316 4.4 Induced Frequency Response rel. to 1kHz .....................................................................................15
68.317 Volume Control unamplified ..................................................................................................................16
68.317 Volume Control maximum .....................................................................................................................17
68.317 Calculating maximum Gain ....................................................................................................................18




 © CTC advanced GmbH                                                                                                                          Page 8 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.2 Axial Field Intensity

                                                                dB(A/m)
Spectrum avg. FFT Size:4096 Overlap:50,0% Hanning              L/dB[V]
  SND(1)                                                             0

                                                                     -10

                                                                     -20

                                                                     -30

                                                                     -40

                                                                     -50

                                                                     -60

                                                                     -70
100              200                   500 f/Hz 1000   2000   5000

Level SND(1): -15.24 dB(A/m) Ok


Ok

2018-10-26 16:58 ACQUA 3.4.100



Limits
                  lower
     Run 1   -22.00 dB(A/m)




 © CTC advanced GmbH                                                 Page 9 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.3 Radial Field Intensity 0 Degree

                                                               dB(A/m)
Spectrum avg. FFT Size:4096 Overlap:50,0% Hanning              L/dB[V]
  SND(1)                                                             0

                                                                     -10

                                                                     -20

                                                                     -30

                                                                     -40

                                                                     -50

                                                                     -60

                                                                     -70
100              200                   500 f/Hz 1000   2000   5000

Level SND(1): -23.08 dB(A/m) Ok


Ok

2018-10-26 16:59 ACQUA 3.4.100



Limits
                  lower
     Run 1   -27.00 dB(A/m)




 © CTC advanced GmbH                                                 Page 10 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.3 Radial Field Intensity 90 Degree

                                                                dB(A/m)
Spectrum avg. FFT Size:4096 Overlap:50,0% Hanning              L/dB[V]
  SND(1)                                                             0

                                                                     -10

                                                                     -20

                                                                     -30

                                                                     -40

                                                                     -50

                                                                     -60

                                                                     -70
100              200                   500 f/Hz 1000   2000   5000

Level SND(1): -24.54 dB(A/m) Ok


Ok

2018-10-26 17:00 ACQUA 3.4.100



Limits
                  lower
     Run 1   -27.00 dB(A/m)




 © CTC advanced GmbH                                                 Page 11 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.3 Radial Field Intensity 180 Degree

Spectrum avg. FFT Size:4096 Overlap:50,0% Hanning              dB(A/m)
                                                                dB(A/m)
                                                              p/dB[Pa]
  SND(1)                                                             0

                                                                     -10

                                                                     -20

                                                                     -30

                                                                     -40

                                                                     -50

                                                                     -60

                                                                     -70
100              200                   500 f/Hz 1000   2000   5000

Level SND(1): -22.43 dB(A/m) Ok


Ok

2018-10-26 17:01 ACQUA 3.4.100



Limits
                  lower
     Run 1   -27.00 dB(A/m)




 © CTC advanced GmbH                                                 Page 12 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.3 Radial Field Intensity 270 Degree

Spectrum avg. FFT Size:4096 Overlap:50,0% Hanning              dB(A/m)
                                                               L/dB[V]
  SND(1)                                                             0

                                                                     -10

                                                                     -20

                                                                     -30

                                                                     -40

                                                                     -50

                                                                     -60

                                                                     -70
100              200                   500 f/Hz 1000   2000   5000

Level SND(1): -23.12 dB(A/m) Ok


Ok

2018-10-26 17:02 ACQUA 3.4.100



Limits
                  lower
     Run 1   -27.00 dB(A/m)




 © CTC advanced GmbH                                                 Page 13 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.4 Induced Frequency Response >= -19 dB

                                                                        dB(A/m)
                                                                        L/dB[V]
              SND(1)                                                          0
              lower limit
              upper limit                                                     -10

                                                                              -20

                                                                              -30

                                                                              -40

                                                                              -50

                                                                              -60

                                                                              -70
   240 300             400       600    800 f/Hz         2000   3000   5000

Max. Peak value SND(1): -23.35 dB(A/m) at 3328.1 Hz Ok




Ok

2018-10-26 16:59 ACQUA 3.4.100



Limits
              upper
     Run 1   0.00 dB




 © CTC advanced GmbH                                                          Page 14 of 24


                 Test report no.: 1-6814/18-01-14



68.316 4.4 Induced Frequency Response rel. to 1kHz

                                                                    dB
                                                                    U/dB[V]
              SND(1)                                                     25
              lower limit                                                20
              upper limit
                                                                           15

                                                                           10
                                                                             5

                                                                             0

                                                                            -5
                                                                          -10

                                                                          -15
                                                                          -20
                                                                          -25
100           200                 500          f/Hz   2000   5000   10k

Minimal distance to lower limit
1.47 dB at 515.6 Hz


Minimal distance to upper limit
2.05 dB at 984.4 Hz


Absolute minimal distance
1.47 dB at 515.6 Hz Ok


Ok

2018-10-26 17:16 ACQUA 3.4.100



Limits
                   lower
     Run 1   Fit into tolerance




 © CTC advanced GmbH                                                      Page 15 of 24


              Test report no.: 1-6814/18-01-14



68.317 Volume Control unamplified

DRP/ERP 3rd Octave FFT Size:4096 Overlap:66,0% Hanning
                                                     L/dB[Pa/V]
                                                       Ref.: ref622.fft
RCV(2)-Ref                                                    50
                                                                   40

                                                                   30

                                                                   20

                                                                   10

                                                                     0

                                                                  -10

                                                                  -20
                                                                  -30
100             200                 500 f/Hz 1000   2000   5000

Correction

X+51

RLR: -8.88 dB
Corrected RLR: 42.12 dB




2018-10-26 16:54 ACQUA 3.4.100




 © CTC advanced GmbH                                              Page 16 of 24


              Test report no.: 1-6814/18-01-14



68.317 Volume Control maximum

DRP/ERP 3rd Octave FFT Size:4096 Overlap:66,0% Hanning
                                                     L/dB[Pa/V]
                                                       Ref.: ref622.fft
RCV(2)-Ref                                                    50
                                                                   40

                                                                   30

                                                                   20

                                                                   10

                                                                     0

                                                                  -10

                                                                  -20
                                                                  -30
100            200                  500 f/Hz 1000   2000   5000

Correction

X+51

RLR: -26.67 dB
Corrected RLR: 24.33 dB




2018-10-26 16:56 ACQUA 3.4.100




 © CTC advanced GmbH                                              Page 17 of 24


                 Test report no.: 1-6814/18-01-14



68.317 Calculating maximum Gain

Correction

  HS_RLR_max_FCC              24.330 dB   2018-10-26   Measured   68.317 Volume Control maximum
  HS_RLR_min_FCC              42.120 dB   2018-10-26   Measured            68.317 Volume Control
                                                                                      unamplified
HS_RLR_min_FCC - HS_RLR_max_FCC

Calculated Value: 17.79 Ok


Ok

2018-10-26 16:57 ACQUA 3.4.100



Limits
              lower      upper
     Run 1   12.00 dB   18.00 dB




 © CTC advanced GmbH                                                                          Page 18 of 24


               Test report no.: 1-6814/18-01-14



10       Test equipment and ancillary equipment used for tests
Software:
     No.    Name                              Manufacturer               Version       Inventory Number
     1      ACQUA                             HEADacoustics              3.4           300003467
     2      HAE-BGN                           HEADacoustics              2.1.100       300003820


     Used software                 :1




Hardware


     No.    Description                       Manufacturer               Type          Inventory Number
     1      Artificial mouth                  B&K                        4227          300000917
     2      Testhead Type 1                   B&K                        4602          300000960
     3      HATS                              HEADacoustics              HMS II.3      300003469
     4      Acoustic chamber                  IAC                        1205-A        300000950
            Reference microphone 2
     5          Microphone cartridge          B&K                        4134          400000101
                Microphone preamplifier       B&K                        2669          400001241
     6      Intern. Feeding bridge            ESP                        ISB 1000      300000967
     7      Calibrator                        B&K                        4231          300000970
     8      Digital Equalizer                 HEADacoustics              PEQ V         300003817
     9      Digital Equalizer                 HEADacoustics              PEQ V         300003818
     10     Digital Equalizer                 HEADacoustics              PEQ V         300003819
     11     GSM/UMTS Simulator                R&S                        CMU 200       300003346
     12     Analog USB Front End              HEADacoustics              MFE VI.1      300003824
     13     Digital Front End for VoIP        HEADacoustics              MFE VIII      400000362
     14     Digital Front End for DECT        HEADacoustics              MFE X         300004015
                                              Communication
     15     HAC Probe - Axial                                            Model A-100   400001215-0000
                                              Certification Laboratory
                                              Communication
     16     HAC Probe - Radial                                           Model R-100   400001215-0001
                                              Certification Laboratory
     17     UMTS /LTE /BT Simulator           R&S                        CMW 500       300004187
            Ear 3.2 ear simulator low leak                               4195 LL       300000965-0000
     18     Ear 3.2 LL Microphone Cartridge   B&K                        4192          300000965-0001
            Microphone preamplifier                                      2669          300004570
            Ear 3.2 ear simulator high leak                              4195 HL       300001242-0000
     19     Ear 3.2 HL Microphone Cartridge   B&K                        4134          300001242-0001
            Microphone preamplifier                                      2669          300004570


     Used components of test equipment                    : 3, 4, 5, 12, 14, 15, 16




 © CTC advanced GmbH                                                                                    Page 19 of 24


             Test report no.: 1-6814/18-01-14



11    Observations

No observations exceeding those reported with the single test cases have been made.




 © CTC advanced GmbH                                                                  Page 20 of 24


            Test report no.: 1-6814/18-01-14



Annex A       Photographs of the test set -up

                             Photo 1: Volume control measurement set-up




                        Photo 2: Volume control measurement set-up (close-up)




© CTC advanced GmbH                                                             Page 21 of 24


            Test report no.: 1-6814/18-01-14




                            Photo 3: Axial field intensity measurement set-up




                      Photo 4: Radial field intensity measurement set-up (0 degree)




© CTC advanced GmbH                                                                   Page 22 of 24


            Test report no.: 1-6814/18-01-14



Annex B       Photographs of the EUT
                                        Photo 5: EUT front side




                                        Photo 6: EUT rear side




© CTC advanced GmbH                                               Page 23 of 24


                Test report no.: 1-6814/18-01-14



Annex C          Document history

 Version        Applied changes                    Date of release

      ---       Initial release                      2018-11-09




Annex D          Further information

Glossary

EUT         -   Equipment Under Test
Inv. No.    -   Inventory number
N/A         -   not applicable
S/N         -   Serial Number
HW          -   Hardware
SW          -   Software
%           -   none




 © CTC advanced GmbH                                     Page 24 of 24



Document Created: 2018-11-09 12:21:44
Document Modified: 2018-11-09 12:21:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC