MPE

FCC ID: TVU-C590C595S795

RF Exposure Info

Download: PDF
FCCID_1161355

CETECOM ICT Services GmbH
Test report no.: 1-1079-01-06/09-FP



7    Safety exposure levels

Prediction of MPE limit at a given distance:

Equation from page 18 of OET Bulletin 65, Edition 97-01

S = PG / 4π R2

where: S = Power density
       P = Power input to the antenna
       G = Antenna gain
       R = Distance to the center of radiation of the antenna



The table below is excerpted from Table 1B of 47 CFR 1.1310 titled “Limits for Maximum Permissible Exposure
(MPE), Limits for General Population/Uncontrolled Exposure”

Frequency Range (MHz)                Power Density (mW/cm2)              Averaging Time (minutes)
300 -1500                            f/1500                              30
1500 - 100000                        1.0                                 30

where f = Frequency (MHz)


Prediction:
P        Max power input to the antenna:            19.79 dBm
P        Max power input to the antenna:            95.28 mW
R        Distance:                                  20 cm
G        Maximum antenna gain:                      3.00 dBi
G        Maximum antenna gain:                      2.0 numeric
S        MPE limit for uncontrolled exposure:       1 mW/cm2


Calculated Power density:                           0.0379 mW/cm2
                                                    0.379 W/m2


This prediction demonstrates the following:

The power density levels at a distance of 20 cm are below the maximum levels allowed by FCC regulations




2009-04-23                                                                                    Page 53 of 59



Document Created: 2009-08-17 11:09:41
Document Modified: 2009-08-17 11:09:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC