RF Exposure Info (MPE).pdf

FCC ID: TVE-140601

RF Exposure Info

Download: PDF
FCCID_3341098

                                                           RF Exposure Report

                       Report No.: SA161021C22

                            FCC ID: TVE-140601

                       Test Model: PCE5501AN-FT

                 Received Date: Oct. 21, 2016

                         Test Date: Nov. 17 ~ Dec. 21, 2016

                     Issued Date: Jan. 05, 2017


                         Applicant: Fortinet lnc.

                          Address: 899 Kifer Road Sunnyvale, CA 94086 USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 (R.O.C.)
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.



Report No.: SA161021C22                                              Page No. 1 / 5                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 5




Report No.: SA161021C22                                              Page No. 2 / 5                                              Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA161021C22           Original release.                                   Jan. 05, 2017




Report No.: SA161021C22                      Page No. 3 / 5        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: 802.11 ac wave2 4x4 module

              Brand: Fortinet lnc.

        Test Model: PCE5501AN-FT

    Sample Status: Engineering sample

          Applicant: Fortinet lnc.

          Test Date: Nov. 17 ~ Dec. 21, 2016

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:        Jan. 05, 2017
                                 Suntee Liu / Specialist




     Approved by :                                               , Date:        Jan. 05, 2017
                               Ken Liu / Senior Manager




Report No.: SA161021C22                         Page No. 4 / 5                       Report Format Version: 6.1.1


2     RF Exposure
2.1 Limits for Maximum Permissible Exposure (MPE)
    Frequency Range          Electric Field     Magnetic Field       Power Density            Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)                 (minutes)
                             Limits For General Population / Uncontrolled Exposure

       300-1500                    …                   …                  F/1500                    30

     1500-100,000                  …                   …                       1.0                  30
F = Frequency in MHz

2.2 MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm

2.3 Classification

The antenna of this product, under normal use condition, is at least 26cm away from the body of the user. So,
this device is classified as Mobile Device.

3     Calculation Result of Maximum Conducted Power

                                                                                       Power
                                         Max Power Antenna Gain      Distance                         Limit
       Mode                 Band                                                      Density
                                           (dBm)       (dBi)           (cm)                         (mW/cm2)
                                                                                     (mW/cm2)
                        WLAN
                                         25.49         12.02              26          0.664              1
                   5180~5240MHz
      CDD
                        WLAN
                                         27.25         12.02              26          0.995              1
                   5745~5825MHz
                        WLAN
                                         19.47         12.02              26          0.166              1
                   5180~5240MHz
 Beamforming
                        WLAN
                                         21.11         12.02              26          0.242              1
                   5745~5825MHz
Note: Max. Directional gain = 6dBi + 10log(4) = 12.02dBi



---END---




Report No.: SA161021C22                        Page No. 5 / 5                          Report Format Version: 6.1.1



Document Created: 2017-12-28 18:04:12
Document Modified: 2017-12-28 18:04:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC