RF_exposure_report

FCC ID: TV7WAPGR5AC2D

RF Exposure Info

Download: PDF
FCCID_4259351

MPE/RF EXPOSURE REPORT




               Company: Mikrotikls SIA (MikroTik)

            Evaluation of: RBwAPGR-5HacD2HnD-US

                 To: FCC CFR 47 Part 1.1310

             Report No.: MIKO81 FCC MPE Rev A


         MPE/RF EXPOSURE REPORT
                                  FROM




Evaluation of: Mikrotikls SIA (MikroTik) RBwAPGR-5HacD2HnD-US

                   To: FCC CFR 47 Part 1.1310

           Report Serial No.: MIKO81 FCC MPE Rev A

                   This report supersedes: NONE

                     Applicant:        Mikrotikls SIA (MikroTik)
                                       Brivibas gatve 214i
                                       Riga, LV-1039
                                       Latvia

            Product Function:          802.11a/n/ac WLAN access point

                   Issue Date:         10th April 2019


     This Report is Issued Under the Authority of:

         MiCOM Labs, Inc.
         575 Boulder Court
         Pleasanton California 94566
         USA
         Phone: +1 (925) 462-0304
         Fax: +1 (925) 462-0306
         www.micomlabs.com

       MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                                Title:     MikroTik RBwAPGR-5HacD2HnD-US
                                                                                  To:      FCC CFR 47 Part 1.1310
                                                                             Serial #:     MIKO81 FCC MPE Rev A




1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
                             2           2
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

The calculations in the table below use the highest conducted power values together with the lowest antenna
gain specified for the EUT. These calculations represent worst case in terms of the exposure levels.
                                                                                 Calculated
                                                      Peak           Peak                         Power
                           Ant       Numeric                                       Power
                                                     Output         Output                       Density         Min Calculated safe
 Freq. Band (MHz)         Gain        Gain                                        Density
                                                     Power          Power                         Limit         distance for Limit (cm)
                          (dBi)     (numeric)                                    (mW/cm2)
                                                     (dBm)          (mW)                        (mW/cm2)
                                                                                  @ 20cm
  5150.0 - 5250.0         2.50         1.78          23.73          236.05          0.09           1.00                   6.00
  2400.0 - 2483.5         2.50         1.78          22.74          188.00          0.07           1.00                   6.00
  5725.0 - 5850.0         2.50         1.78          22.08          161.47          0.06           1.00                   5.00


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations
indicate the MPE distance to be less.

Specification - Maximum Permissible Exposure Limits

The Limit is defined in Table 1 of FCC §1.1310.




                 Issue Date:       10th April 2019                                             Page:      3 of 4
                  This Report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.
    MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com