Test Report

FCC ID: TV7RB951UI-2ND

Test Report

Download: PDF
FCCID_2781619

   NVLAP Lab Code 200087-0




                             Submittal Application
                                    Report
                                      FOR
                             GRANT OF CERTIFICATION
                                                    FOR


                                    Model: RB951Ui-2nD
                                       2412-2462 MHz
                             Broadband Digital Transmission System
                                  FCC ID: TV7RB951UI-2ND
                                     IC: 7442A-9512ND
                                                    FOR


                                        Mikrotikls SIA
                                            Pernavas 46
                                         Riga, Latvia LV-1009

                                   Test Report Number: 150901
                                IC Test Site Registration: 3041A-1

   Authorized Signatory:
                               Scot D. Rogers




Rogers Labs, Inc.                    Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                  Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214            Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                           File: Mikrotik RB951UI2nD TstRpt 150901 Page 1 of 33


   NVLAP Lab Code 200087-0




                                 ROGERS LABS, INC.
                                 4405 West 259th Terrace
                                 Louisburg, KS 66053
                                 Phone / Fax (913) 837-3214



                                Engineering Test Report for
                              Grant of Certification Application
                                                       FOR
                              Broadband Digital Transmission System
                             CFR 47, PART 15C - Paragraph 15.247
                                   License Exempt Intentional Radiator
                                                        For


                                           Mikrotikls SIA
                                                   Pernavas 46
                                               Riga, Latvia LV-1009

                                       Broadband Digital Transmission System

                                              Model: RB951Ui-2nD
                                         Frequency Range 2412-2462 MHz
                                           FCC ID#: TV7RB951UI-2ND
                                               IC: 7442A-9512ND

   Test Date: September 1, 2015

   Certifying Engineer:
                                Scot D. Rogers
                                Rogers Labs, Inc.
                                4405 West 259th Terrace
                                Louisburg, KS 66053
                                Telephone/Facsimile: (913) 837-3214

   This report shall not be reproduced except in full, without the written approval of the laboratory.
   This report must not be used by the client to claim product certification, approval, or endorsement by
   NVLAP, NIST, or any agency of the Federal Government.
Rogers Labs, Inc.                     Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                 Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                   Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214             Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                            File: Mikrotik RB951UI2nD TstRpt 150901 Page 2 of 33


   NVLAP Lab Code 200087-0




   Table Of Contents
   TABLE OF CONTENTS....................................................................................................... 3
   REVISIONS.......................................................................................................................... 4
   FORWARD .......................................................................................................................... 5
   OPINION / INTERPRETATION OF RESULTS .................................................................... 5
   EQUIPMENT TESTED ......................................................................................................... 5
   EQUIPMENT FUNCTION AND CONFIGURATION............................................................. 6
            Equipment Configuration........................................................................................................................................... 6
   APPLICATION FOR CERTIFICATION ................................................................................ 7
   APPLICABLE STANDARDS & TEST PROCEDURES ....................................................... 8
   EQUIPMENT TESTING PROCEDURES ............................................................................. 8
            AC Line Conducted Emission Test Procedure ......................................................................................................... 8
            Radiated Emission Test Procedure ............................................................................................................................ 8
               Diagram 1 Test arrangement for Conducted emissions .............................................................................................. 9
               Diagram 2 Test arrangement for radiated emissions of tabletop equipment ............................................................. 10
               Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS) .................................. 11
   TEST SITE LOCATIONS ................................................................................................... 11
   LIST OF TEST EQUIPMENT ............................................................................................. 12
   UNITS OF MEASUREMENTS ........................................................................................... 13
   ENVIRONMENTAL CONDITIONS..................................................................................... 13
   INTENTIONAL RADIATORS ............................................................................................. 13
            Antenna Requirements ............................................................................................................................................. 13
            Restricted Bands of Operation ................................................................................................................................. 13
               Table 1 General Radiated Emissions in Restricted Bands Data ............................................................................... 14
            Summary of Results for Radiated Emissions in Restricted Bands ....................................................................... 14
            AC Line Conducted Emissions Procedure .............................................................................................................. 15
               Figure 1 AC Line Conducted Emissions Line 1 ....................................................................................................... 16
               Figure 2 AC Line Conducted Emissions Line 2 ....................................................................................................... 16
               Table 2 AC Line Conducted Emissions Data (Highest Emissions Line L1) ............................................................ 17
               Table 3 AC Line Conducted Emissions Data (Highest Emissions Line L2) ............................................................ 17
            Summary of Results for AC Line Conducted Emissions ....................................................................................... 17
            General Radiated Emissions Procedure .................................................................................................................. 18
               Table 4 General Radiated Emissions from EUT Data (Highest Emissions) ............................................................. 19
            Summary of Results for General Radiated Emissions ........................................................................................... 19
            Operation in the 2400-2483.5 MHz Frequency Band ............................................................................................. 20
               Figure 3 Plot of Transmitter Emissions (Across Operational Band 802.11b) .......................................................... 21

Rogers Labs, Inc.                                       Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                                   Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                                     Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                               Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                              File: Mikrotik RB951UI2nD TstRpt 150901 Page 3 of 33


   NVLAP Lab Code 200087-0




               Figure 4 Plot of Transmitter Emissions (Across Operational Band, 802.11g) ......................................................... 21
               Figure 5 Plot of Transmitter Emissions (Across Operational Band, 802.11n) ......................................................... 22
               Figure 6 Plot of Transmitter Low Band Edge (802.11b) .......................................................................................... 22
               Figure 7 Plot of Transmitter Low Band Edge (802.11g) .......................................................................................... 23
               Figure 8 Plot of Transmitter Low Band Edge (802.11n) .......................................................................................... 23
               Figure 9 Plot of Transmitter High Band Edge (802.11b) ......................................................................................... 24
               Figure 10 Plot of Transmitter High Band Edge (802.11g) ....................................................................................... 24
               Figure 11 Plot of Transmitter High Band Edge (802.11n) ....................................................................................... 25
            Transmitter Emissions Data ..................................................................................................................................... 25
               Table 5 Transmitter Power and Emissions ............................................................................................................... 25
               Table 6 Transmitter Radiated Emission .................................................................................................................... 26
            Summary of Results for Transmitter Radiated Emissions of Intentional Radiator ............................................ 27
   STATEMENT OF MODIFICATIONS AND DEVIATIONS .................................................. 27
   ANNEX ............................................................................................................................... 28
            Annex A Measurement Uncertainty Calculations .................................................................................................. 29
            Annex B Rogers Labs Test Equipment List ............................................................................................................ 30
            Annex C Rogers Qualifications ................................................................................................................................ 31
            Annex D FCC Site Registration Letter .................................................................................................................... 32
            Annex E Industry Canada Site Registration Letter ............................................................................................... 33




    Revisions
   Revision 1 Issued October 12, 2015




Rogers Labs, Inc.                                      Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                                  Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                                    Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                              Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                             File: Mikrotik RB951UI2nD TstRpt 150901 Page 4 of 33


   NVLAP Lab Code 200087-0




   Forward
   The following information is submitted for consideration in obtaining Grant of Certification for
   License Exempt Digital Transmission System Intentional Radiator operating under 47CFR
   Paragraph 15.247 and RSS-247 Issue 1 Digital Modulation transmitter operation in the 2412-2462
   MHz band.

                    Name of Applicant:   Mikrotikls SIA       FRN: 0014 43 1100
                                         Pernavas 46
                                         Riga, Latvia LV-1009
                    Model: RB951Ui-2nD
                    FCC ID: TV7RB951UI-2ND             IC: 7442A-9512ND
                    Frequency Range: 2412-2462 MHz (802.11a/b/g mode operation), 2422-2452 MHz (802.11n
                                      40 MHz channel operation)
                    Total Operating Power: Maximum 0.161-watt total output power (0.08 watts per chain),
                                           OBW 16,720 or 36,780 kHz
   Opinion / Interpretation of Results

                                 Tests Performed                      Margin (dB)       Results
     Restricted Frequency Bands 15.205, RSS-GEN 8.10                      -0.6         Complies
     AC Line Conducted 15.207, RSS-GEN 7.2.4                              -8.3         Complies
     Radiated Emissions 15.209, RSS-GEN 7.2.5                             -11.5        Complies
     Harmonic Emissions per 15.247, RSS-210                               -0.4         Complies
     Peak Power Spectral Density per 15.247, RSS-210                      -12.8        Complies


   Equipment Tested
   Equipment                             Model                      FCC I.D.

   EUT                                   RB951Ui-2nD                TV7RB951UI-2ND

   AC Adapter                            FLD181-240075-U            N/A

   Dell Studio XPS                       921LBN1                    N/A




Rogers Labs, Inc.                        Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                    Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                      Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                               File: Mikrotik RB951UI2nD TstRpt 150901 Page 5 of 33


   NVLAP Lab Code 200087-0




   Equipment Function and Configuration

   The EUT is a 2412-2462 MHz 2x2 MIMO Digital Transmission System used to transmit data in
   applications offering broadband wireless connectivity. The design utilizes internal fixed antenna
   system and offers no provision for antenna replacement or modification. The equipment is marketed
   for use to incorporate a wireless link to exchange data information from one point to another. For
   testing purposes, the EUT transceiver was connected to the manufacturer supplied AC/DC supply
   and communicating to the laptop computer through Ethernet network interface. This configuration
   provided operational control of the EUT and communications over the network interface between
   the EUT and supporting computer system. No other interfacing options are provided. For testing
   purposes, the RB951Ui-2nD received powered from the manufacturer provided AC/DC power
   adapter and was configured to transmit in available data modes. The antenna system complies with
   requirements for unique antenna connection port.



   Equipment Configuration



                                               Network Cable       Laptop Computer
                                (EUT)                                   (CPU)



                                                                    CPU AC Power
                                                                      Adapter
                             AC/DC Adapter


                                                                     Utility Power




Rogers Labs, Inc.                       Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                   Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                     Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214               Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                              File: Mikrotik RB951UI2nD TstRpt 150901 Page 6 of 33


   NVLAP Lab Code 200087-0




   Application for Certification
    (1)             Manufacturer:          Mikrotikls SIA
                                           Pernavas 46
                                           Riga, Latvia LV-1009

    (2)             Identification: Models: RB951Ui-2nD

                    FCC I.D.: TV7RB951UI-2ND              IC: 7442A-9512ND

   (3)              Instruction Book:

                    Refer to Exhibit for Instruction Manual.

   (4)              Description of Circuit Functions:

                    Refer to Exhibit of Operational Description.

   (5)              Block Diagram with Frequencies:

                    Refer to Exhibit of Operational Description.

   (6)              Report of Measurements:

                    Report of measurements follows in this Report.

   (7)              Photographs: Construction, Component Placement, etc.:

                    Refer to Exhibit for photographs of equipment.

   (8)              List of Peripheral Equipment Necessary for operation. The equipment operates from power
                    received from authorized AC/DC power adapter. The EUT provides five Ethernet ports, USB
                    interface and DC input power port for operation. During testing, the EUT was connected to
                    CPU through network cable. The EUT received power supplied from external AC/DC supply

   (9)              Transition Provisions of 47CFR 15.37 are not requested

   (10)             Not Applicable. The unit is not a scanning receiver.

   (11)             Not Applicable. The EUT does not operate in the 59 – 64 GHz frequency band.

   (12)             The equipment is not software defined and this section is not applicable.




Rogers Labs, Inc.                          Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                      Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                        Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                  Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                 File: Mikrotik RB951UI2nD TstRpt 150901 Page 7 of 33


   NVLAP Lab Code 200087-0




   Applicable Standards & Test Procedures
   The following information is submitted in accordance 47CFR dated October 1, 2014, Part 2,
   Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926, 2.1031 through 2.1057, and applicable
   parts of paragraph 15, Part 15C Paragraph 15.247 and Industry Canada RSS-247. Test
   procedures used are the established Methods of Measurement of Radio-Noise Emissions as
   described in ANSI C63.10-2013, KDB 558074 D01 v03r03, KDB 662911 D02 v01, and KDB
   913591, RSS-247, Issue 1 and RSS-GEN Issue 4, the following information is submitted for
   processing application for Certification.

   Equipment Testing Procedures
   AC Line Conducted Emission Test Procedure
   Testing for the AC line-conducted emissions was performed as defined in ANSI C63.10-2013.
   The test setup, including the EUT, was arranged in the test configurations as presented during
   testing. The test configuration was placed on a 1 x 1.5-meter wooden bench, 0.8 meters high
   located in a screen room. The power lines of the system were isolated from the power source
   using a standard LISN with a 50-µHy choke. EMI was coupled to the spectrum analyzer through
   a 0.1 µF capacitor internal to the LISN. The LISN was positioned on the floor beneath the
   wooden bench supporting the EUT. The power lines and cables were draped over the back edge
   of the table. Refer to diagram 1 showing typical test arrangement and photographs in exhibits
   for EUT placement used during testing.

   Radiated Emission Test Procedure
   Radiated emission testing was performed as required and specified in ANSI C63.10-2013 and
   referenced KDB documents. The EUT was placed on a rotating 0.9 x 1.2-meter platform,
   elevated as required above the ground plane at a distance of 3 meters from the FSM antenna.
   The table permitted orientation of the EUT in each of three orthogonal axis positions during
   testing. EMI energy was maximized by equipment placement, raising and lowering the FSM
   antenna, changing the antenna polarization, and by rotating the turntable. Each emission was
   maximized before data was taken using a spectrum analyzer. The frequency spectrum from 9
   kHz to 25,000 MHz was searched for during preliminary investigation. Refer to diagrams 2 and
   3 showing typical test arrangement and photographs in the test setup exhibits for specific EUT
   placement during testing.

Rogers Labs, Inc.                Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace            Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053              Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214        Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                       File: Mikrotik RB951UI2nD TstRpt 150901 Page 8 of 33


   NVLAP Lab Code 200087-0




   1. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
      forth in the center forming a bundle 30 cm to 40 cm long see (see 6.2.3.2).
   2. The I/O cables that are not connected to an accessory shall be bundled in the center. The end of
      the cable may be terminated, if required, using the correct terminating impedance. The overall
      length shall not exceed 1 m (see 6.2.2).
   3. EUT connected to one LISN. Unused LISN measuring port connectors shall be terminated in 50 Ω
      loads. LISN may be placed on top of, or immediately beneath, reference ground plane (see 6.2.2
      and 6.2.3).
       3.1 All other equipment powered from additional LISN(s).
       3.2 Multiple-outlet strip can be used for multiple power cords of non-EUT equipment.
       3.3 LISN at least 80 cm from nearest part of EUT chassis
   4. Non-EUT components of EUT system being tested
   5. Rear of EUT, including peripherals, shall all be aligned and flush with edge of tabletop (see
      6.2.3.2).
   6. Edge of tabletop shall be 40 cm removed from a vertical conducting plane that is bonded to the
      ground plane (see 6.2.2 for options).
   7. Antenna may be integral or detachable. If detachable, the antenna shall be attached for this test.
   Diagram 1 Test arrangement for Conducted emissions



Rogers Labs, Inc.               Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace           Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053             Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214       Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                      File: Mikrotik RB951UI2nD TstRpt 150901 Page 9 of 33


   NVLAP Lab Code 200087-0




   1. A LISN is optional for radiated measurements between 30 MHz and 1000 MHz but not allowed
      for measurements below 30 MHz and above 1000 MHz (see 6.3.1). If used, then connect EUT to
      one LISN. Unused LISN measuring port connectors shall be terminated in 50 Ω loads. The LISN
      may be placed on top of, or immediately beneath, the reference ground plane (see 6.2.2 and
      6.2.3.2).
       1.1 LISN spaced at least 80 cm from nearest part of EUT chassis.
   2. Antenna can be integral or detachable, depending on the EUT (see 6.3.1).
   3. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
      forth in the center forming a bundle 30 cm to 40 cm long (see 6.3.1).
   4. For emission measurements at or below 1 GHz, the table height shall be 80 cm. For emission
      measurements above 1 GHz, the table height shall be 1.5 m for measurements, except as
      otherwise specified (see 6.3.1 and 6.6.3.1).

   Diagram 2 Test arrangement for radiated emissions of tabletop equipment



Rogers Labs, Inc.               Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace           Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053             Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214       Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                      File: Mikrotik RB951UI2nD TstRpt 150901 Page 10 of 33


   NVLAP Lab Code 200087-0




                                                                       Appropriate
                                                                       Frequency
                                                                       Dependent
                                                                       Antenna




                                            0.8 – 1.5 m




            Frequency: 9 kHz-30 MHz               Frequency: 30 MHz- 1 GHZ            Frequency: Above 1 GHz
                             Loop Antenna             Broadband Biconilog                     Horn
                             RBW = 9 kHz                   RBW = 120 kHz                  RBW = 1 MHz
                         VBW = 30 kHz                      VBW = 120 kHz                  VBW = 1 MHz
                     Sweep time = Auto                    Sweep time = Auto             Sweep time = Auto
                     Detector = PK, QP                    Detector = PK, QP             Detector = PK, AV
         Antenna Height 1m          Antenna Height 1-4m          Antenna Height 1-4m
   Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS)

   Test Site Locations
   Conducted EMI                       The AC power line conducted emissions testing performed in a shielded
                                       screen room located at Rogers Labs, Inc., 4405 W. 259th Terrace, Louisburg,
                                       KS
   Radiated EMI                        The radiated emissions tests were performed at the 3 meters, Open Area Test
                                       Site (OATS) located at Rogers Labs, Inc., 4405 W. 259th Terrace, Louisburg,
                                       KS
   Site Registration                   Refer to Annex for Site Registration Letters
   NVLAP Accreditation                        Lab code 200087-0

Rogers Labs, Inc.                             Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                         Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                           Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                     Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                    File: Mikrotik RB951UI2nD TstRpt 150901 Page 11 of 33


   NVLAP Lab Code 200087-0




   List of Test Equipment
   A Rohde and Schwarz ESU40 and/or Hewlett Packard 8591EM was used as the measuring device
   for the emissions testing of frequencies below 1 GHz. A Rohde and Schwarz ESU40 and/or
   Hewlett Packard 8562A Spectrum Analyzer was used as the measuring device for testing the
   emissions at frequencies above 1 GHz. The analyzer settings used are described in the following
   table. Refer to the appendix for a complete list of test equipment.

                                       AC Line Conducted Emissions (0.150 -30 MHz)
                              RBW                      AVG. BW                Detector Function
                              9 kHz                      30 kHz               Peak / Quasi Peak
                                                Emissions (30-1000 MHz)
                              RBW                      AVG. BW                Detector Function
                             120 kHz                    300 kHz               Peak / Quasi Peak
                                               Emissions (Above 1000 MHz)
                              RBW                      Video BW               Detector Function
                             100 kHz                    100 kHz                      Peak
                             1 MHz                       1 MHz                  Peak / Average
   Equipment      Manufacturer      Model (SN)              Band          Cal Date    Due
       LISN       FCC      FCC-LISN-50-2-10(1PA) (160611) .15-30MHz       6/15       5/16
       Cable      Time Microwave 750HF290-750 (L10M) 9kHz-40 GHz 10/14               10/15
       Cable      Belden            RG-58 (L1-CAT3-11509) 9kHz-30 MHz 10/14          10/15
       Cable      Belden            RG-58 (L2-CAT3-11509) 9kHz-30 MHz 10/14          10/15
       Antenna ARA                  BCD-235-B (169)         20-350MHz 10/14          10/15
       Antenna EMCO                 3147 (40582)            200-1000MHz 10/14        10/15
       Antenna ETS-Lindgren         3117 (200389)           1-18 GHz      5/15       5/17
       Antenna Com Power            AH-118 (10110)          1-18 GHz      10/14      10/16
       Antenna Com Power            AH-840 (101046)         18-40 GHz     5/15       5/17
       Antenna EMCO                 6509 (9502-1374)        .001-30 MHz 10/14        10/15
       Antenna Sunol                JB-6 (A100709)          30-1000 MHz 10/14        10/15
       Antenna EMCO                 3143 (9607-1277)        20-1200 MHz 5/15         5/16
       Analyzer HP                  8591EM (3628A00871) 9kHz-1.8GHz 5/15             5/16
       Analyzer HP                  8562A (3051A05950)      9kHz-110GHz 5/15         5/16
       Analyzer HP External Mixers11571, 11970              25GHz-110GHz5/15         5/16
       Analyzer Rohde & Schwarz ESU40 (100108)              20Hz-40GHz 5/15          5/16
       Amplifier Com-Power          PA-010 (171003)         100Hz-30MHz 10/14        10/15
       Amplifier Com-Power          CPPA-102 (01254)        1-1000 MHz 10/14         10/15
       Amplifier Com-Power          PAM-118A (551014)       0.5-18 GHz    10/14      10/15
Rogers Labs, Inc.              Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace          Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053            Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214      Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                     File: Mikrotik RB951UI2nD TstRpt 150901 Page 12 of 33


   NVLAP Lab Code 200087-0




   Units of Measurements
   Conducted EMI                    Data is in dBµV; dB referenced to one microvolt
   Radiated EMI                     Data is in dBµV/m; dB/m referenced to one microvolt per meter
   Sample Calculation:
                             RFS = Radiated Field Strength, FSM = Field Strength Measured
                             A.F. = Receive antenna factor, Gain = amplification gains and/or cable losses
                             RFS (dBµV/m @ 3m) = FSM (dBµV) + A.F. (dB) - Gain (dB)
   Environmental Conditions
                    Ambient Temperature            23.2° C
                    Relative Humidity              47%
                    Atmospheric Pressure           1013.5 mb
   Intentional Radiators
   As per 47CFR part 15 subpart C, and Industry Canada RSS-247, Issue 1, the following information
   is submitted for consideration and demonstration of compliance with regulation and standards.

   Antenna Requirements
   The EUT incorporates integral antenna system and offers no provision for connection to alternate
   system. The antenna connection point complies with the unique antenna connection requirements.
   The requirements of 15.203 are fulfilled; there are no deviations or exceptions to the specification.

   Restricted Bands of Operation
   Spurious emissions falling in the restricted frequency bands of operation were measured at the
   antenna port with radiated emissions measured on the OATS. The EUT utilizes frequency,
   determining circuitry, which generates harmonics falling in restricted bands. Emissions were
   investigated at the antenna port and OATS, using appropriate antennas or pyramidal horns,
   amplification stages, and spectrum analyzer. Peak and average amplitudes of frequencies above
   1000 MHz were compared to the required limits with worst-case data presented below. Test
   procedures of ANSI C63.10-2013 were used during testing. No other significant emission was
   observed which fell into the restricted bands of operation. Computed radiated emission values take
   into account the measured radiated field strength, receive antenna correction factor, amplifier gain
   stage, and test system cable losses.


Rogers Labs, Inc.                          Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                      Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                        Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                  Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                 File: Mikrotik RB951UI2nD TstRpt 150901 Page 13 of 33


   NVLAP Lab Code 200087-0




   Table 1 General Radiated Emissions in Restricted Bands Data
          Frequency in       Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
             MHz               Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                             (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

             2390.0            53.6         N/A          45.5        47.1         N/A         31.2         54.0
             2483.5            56.5         N/A          52.1        42.8         N/A         28.6         54.0
             4824.0            56.2         N/A          53.4        49.7         N/A         43.3         54.0
             4874.0            54.4         N/A          52.8        49.5         N/A         44.5         54.0
             4924.0            55.8         N/A          53.6        50.5         N/A         45.1         54.0
             7236.0            51.1         N/A          39.5        51.4         N/A         39.8         54.0
             7311.0            47.4         N/A          35.4        50.5         N/A         39.4         54.0
             7386.0            46.9         N/A          34.7        50.4         N/A         39.5         54.0
            12060.0            50.7         N/A          38.6        51.7         N/A         39.1         54.0
            12185.0            51.2         N/A          38.8        53.8         N/A         40.2         54.0
            12310.0            51.0         N/A          38.5        51.7         N/A         39.2         54.0
            14472.0            52.5         N/A          39.8        52.3         N/A         40.0         54.0
   Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
   amplitude emissions are recorded above for frequency range below 1000 MHz. Peak and Average
   amplitude emissions are recorded above for frequency range above 1000 MHz.

   Summary of Results for Radiated Emissions in Restricted Bands

   The EUT demonstrated compliance with the emissions requirements of 47CFR 15.205, RSS-
   GEN and RSS-247, Issue 1 Intentional Radiators. The EUT provided a worst-case minimum
   margin of -0.6 dB below the emissions requirements in restricted frequency bands. Peak, Quasi-
   peak, and average amplitudes were checked for compliance with the regulations. Worst-case
   emissions are reported with other emissions found in the restricted frequency bands at least 20
   dB below the requirements.




Rogers Labs, Inc.                            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 14 of 33


   NVLAP Lab Code 200087-0




   AC Line Conducted Emissions Procedure

   The EUT was arranged in a typical equipment configuration and placed on a 1 x 1.5-meter
   wooden bench 80 cm above the conducting ground plane, floor of a screen room. The bench was
   positioned 40 cm away from the wall of the screen room. The LISN was positioned on the floor
   of the screen room 80-cm from the rear of the EUT. The manufacturer supplied supporting
   equipment, which provided direct current power to the EUT and was connected to the LISN. A
   second LISN was positioned on the floor of the screen room 80-cm from the rear of the
   supporting equipment of the EUT. All power cords except the EUT support equipment power
   the EUT were then powered from the second LISN. EMI was coupled to the spectrum analyzer
   through a 0.1 μF capacitor, internal to the LISN. Power line conducted emissions testing were
   carried out individually for each current carrying conductor of the EUT support equipment. The
   excess length of lead between the system and the LISN receptacle was folded back and forth to
   form a bundle not exceeding 40 cm in length. The screen room, conducting ground plane,
   analyzer, and LISN were bonded together to the protective earth ground. Preliminary testing was
   performed to identify the frequency of each emission displaying the highest amplitude. The
   cables were repositioned to obtain maximum amplitude of measured EMI level. Once the worst-
   case configuration was identified, plots were made of the EMI from 0.15 MHz to 30 MHz then
   the data was recorded with maximum conducted emissions levels. Refer to figures one and two
   for plots of the EUT support equipment AC Line Conducted emissions.




Rogers Labs, Inc.               Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace           Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053             Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214       Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                      File: Mikrotik RB951UI2nD TstRpt 150901 Page 15 of 33


   NVLAP Lab Code 200087-0




   Figure 1 AC Line Conducted Emissions Line 1




   Figure 2 AC Line Conducted Emissions Line 2

Rogers Labs, Inc.            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 16 of 33


   NVLAP Lab Code 200087-0




   Table 2 AC Line Conducted Emissions Data (Highest Emissions Line L1)




   Other emissions present had amplitudes at least 20 dB below the limit.
   Table 3 AC Line Conducted Emissions Data (Highest Emissions Line L2)




   Other emissions present had amplitudes at least 20 dB below the limit.

   Summary of Results for AC Line Conducted Emissions

   The EUT test system demonstrated compliance to the conducted emissions requirements of RSS-
   210 Issue 8 and RSS-GEN. The EUT demonstrated minimum margin of -8.3 dB below the limit.
   Measurements were taken using the peak, quasi peak, and average, measurement function for
   each emissions amplitude and were below the limits stated in the specification. Other emissions
   were present with recorded data representing worst-case amplitudes.

Rogers Labs, Inc.               Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace           Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053             Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214       Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                      File: Mikrotik RB951UI2nD TstRpt 150901 Page 17 of 33


   NVLAP Lab Code 200087-0




   General Radiated Emissions Procedure

   The EUT was arranged in a typical equipment configuration and operated through all available
   modes with worst-case data recorded. Preliminary testing was performed in a screen room with
   the EUT positioned 1 meter from the FSM. Radiated emissions measurements were performed
   to identify the frequencies, which produced the highest emissions. Each radiated emission was
   then maximized at the OATS location before final radiated emissions measurements were
   performed. Final data was taken with the EUT located at the OATS at a distance of 3 meters
   between the EUT and the receiving antenna. The frequency spectrum from 9 kHz to 25,000
   MHz was searched for general radiated emissions. Measured emission levels were maximized
   by EUT placement on the table, rotating the turntable through 360 degrees, varying the antenna
   height between 1 and 4 meters above the ground plane and changing antenna position between
   horizontal and vertical polarization. Antennas used were Loop from 9 kHz to 30 MHz,
   Broadband Biconical from 30 to 200 MHz, Biconilog from 30 to 1000 MHz, Log Periodic from
   200 MHz to 1 GHz and or Double Ridge or pyramidal horns and mixers from 1 GHz to 25 GHz,
   notch filters, and appropriate amplifiers and external mixers were utilized.




Rogers Labs, Inc.                Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace            Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053              Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214        Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                       File: Mikrotik RB951UI2nD TstRpt 150901 Page 18 of 33


   NVLAP Lab Code 200087-0




   Table 4 General Radiated Emissions from EUT Data (Highest Emissions)
          Frequency in       Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
             MHz               Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                             (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)    (dBµV/m)


                47.0           29.6         23.4         N/A         31.8         27.2        N/A          40.0

                47.6           28.8         22.8         N/A         30.7         25.7        N/A          40.0

                48.2           29.7         23.0         N/A         29.7         23.5        N/A          40.0

                94.4           30.6         25.2         N/A         36.5         32.1        N/A          43.6

               101.8           31.5         26.2         N/A         35.7         30.7        N/A          43.6

               143.4           29.2         23.7         N/A         27.9         23.6        N/A          43.6

               155.7           30.3         24.6         N/A         27.0         22.1        N/A          43.6

               157.3           30.2         23.5         N/A         26.0         20.9        N/A          43.6

               202.0           29.9         24.4         N/A         26.3         20.6        N/A          43.6

               375.0           29.6         27.1         N/A         30.0         27.1        N/A          46.0
   Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
   amplitude emissions are recorded above for frequency range below 1000 MHz. Peak and Average
   amplitude emissions are recorded above for frequency range above 1000 MHz.

   Summary of Results for General Radiated Emissions

   The EUT demonstrated compliance with the radiated emissions requirements of 47CFR part 15
   and Industry Canada RSS-247 Issue 1 Intentional Radiators. The EUT demonstrated a minimum
   margin of -11.5 dB below the requirements. Other emissions were present with amplitudes at
   least 20 dB below the Limits.




Rogers Labs, Inc.                            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 19 of 33


   NVLAP Lab Code 200087-0




   Operation in the 2400-2483.5 MHz Frequency Band

   Radiated emissions were measured on the Open Area Test Site (OATS) at a three-meter distance.
   The EUT utilizes permanently attached printed circuit board antenna. The EUT was placed on a
   turntable elevated as required above the ground plane at a distance of 3 meters from the FSM
   antenna located on the OATS. The table permitted orientation of the EUT in each of three
   orthogonal axis positions during testing. The peak and quasi-peak amplitude of the frequencies
   below 1000 MHz were measured using a spectrum analyzer. The peak and average amplitude of
   emissions above 1000 MHz were measured using a spectrum analyzer. Emissions data was
   recorded from the measurement results. Data presented reflects measurement result corrected to
   account for measurement system gains and losses. Plots were made of transmitter performance
   for reference purposes. Refer to figures three through eleven showing plots of the EUT
   performance displaying compliance with the specifications.

   This product utilizes permanently attached antenna system and offers no provision for antenna
   port conducted measurements. As such, the testing procedures as defined in publications KDB
   558074 D01 DTS Meas Guidance v03r03, KDB 662911 D02, and ANSI C63.10-2013 were
   utilized during compliance testing. These procedures provide for antenna port measurement or
   measurement of maximum field strength and conversion calculations for comparison with
   requirements.

           1. The transmitter's peak power was measured as specified in 9.1.2 of KDB 558074
           2. Emission DTS Bandwidth was measured in compliance with KDB 558074 paragraph 8.
           3. Maximum Power Spectral Density was measured in compliance with KDB 662911
                    paragraph 10.
           4. Unwanted Radiated Emissions were measured in compliance with KDB 558074
                    paragraph 11 and specified in ANSI C63-10 at a 3-meters distance located on the OATS.
           5. Radiated Emissions Levels in restricted bands were measured in compliance with KDB
                    558074 paragraph 12, specified in ANSI C63-10 at a 3-meters distance located on the
                    OATS.
           6. Band-Edge measurements were performed in compliance with KDB 558074 paragraph
                    13 and specified in ANSI C63-10.
Rogers Labs, Inc.                        Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                    Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                      Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                               File: Mikrotik RB951UI2nD TstRpt 150901 Page 20 of 33


   NVLAP Lab Code 200087-0




   Figure 3 Plot of Transmitter Emissions (Across Operational Band 802.11b)




   Figure 4 Plot of Transmitter Emissions (Across Operational Band, 802.11g)

Rogers Labs, Inc.             Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace         Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053           Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214     Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                    File: Mikrotik RB951UI2nD TstRpt 150901 Page 21 of 33


   NVLAP Lab Code 200087-0




   Figure 5 Plot of Transmitter Emissions (Across Operational Band, 802.11n)




   Figure 6 Plot of Transmitter Low Band Edge (802.11b)

Rogers Labs, Inc.             Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace         Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053           Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214     Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                    File: Mikrotik RB951UI2nD TstRpt 150901 Page 22 of 33


   NVLAP Lab Code 200087-0




   Figure 7 Plot of Transmitter Low Band Edge (802.11g)




   Figure 8 Plot of Transmitter Low Band Edge (802.11n)

Rogers Labs, Inc.            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 23 of 33


   NVLAP Lab Code 200087-0




   Figure 9 Plot of Transmitter High Band Edge (802.11b)




   Figure 10 Plot of Transmitter High Band Edge (802.11g)

Rogers Labs, Inc.            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 24 of 33


   NVLAP Lab Code 200087-0




   Figure 11 Plot of Transmitter High Band Edge (802.11n)


   Transmitter Emissions Data

   Table 5 Transmitter Power and Emissions

          Frequency          Calculated Conducted Antenna   6-dB Occupied     Calculated Power
            MHz               Port Output Power (Watts)     Bandwidth kHz   Spectral Density dBm

                                                20 MHz Mode

              2412.0                    0.161                  1,612.6             -4.81

              2437.0                    0.150                  1,672.0             -4.85

              2462.0                    0.137                  1,616.5             -4.92

                                                40 MHz Mode

              2422.0                    0.095                  36,770              -8.85

              2447.0                    0.091                  36,780              -8.80

              2452.0                    0.085                  36,750              -8.68


Rogers Labs, Inc.                         Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                     Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                       Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                 Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                File: Mikrotik RB951UI2nD TstRpt 150901 Page 25 of 33


   NVLAP Lab Code 200087-0




   Table 6 Transmitter Radiated Emission

         Frequency in          Horizontal        Horizontal      Vertical Peak   Vertical Average   Limit @ 3m
            MHz              Peak (dBµV/m)    Average (dBµV/m)    (dBµV/m)          (dBµV/m)         (dBµV/m)

             2412.0             104.3              96.9             100.8             93.3              --

             4824.0              56.2              53.4             49.7              43.3            54.0

             7236.0              51.1              39.5             51.4              39.8            54.0

             9648.0              47.5              35.5             49.1              39.8            54.0

            12060.0              50.7              38.6             51.7              39.1            54.0

            14472.0              52.5              39.8             52.3              40.0            54.0

            16884.0              56.1              43.4             56.2              43.7            54.0

             2437.0             104.0              96.5             100.5             93.6              --

             4874.0              54.4              52.8             49.5              44.5            54.0

             7311.0              47.4              35.4             50.5              39.4            54.0

             9748.0              49.7              38.3             51.8              43.9            54.0

            12185.0              51.2              38.8             53.8              40.2            54.0

            14622.0              53.3              40.9             53.9              41.5            54.0

            17059.0              57.6              45.2             58.2              45.5            54.0

             2462.0             103.6              95.5             99.6              92.6              --

             4924.0              55.8              53.6             50.5              45.1            54.0

             7386.0              46.9              34.7             50.4              39.5            54.0

             9848.0              47.4              35.6             48.3              38.6            54.0

            12310.0              51.0              38.5             51.7              39.2            54.0

            14772.0              54.2              41.5             53.8              41.5            54.0

            17234.0              58.6              44.8             57.6              44.8            54.0
   Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
   amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and Average
   amplitude emissions are recorded above for frequency range above 1000 MHz.

Rogers Labs, Inc.                            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 26 of 33


   NVLAP Lab Code 200087-0




   Summary of Results for Transmitter Radiated Emissions of Intentional Radiator

   The EUT demonstrated compliance with the radiated emissions requirements of 47CFR Part
   15.247 and Industry Canada RSS-247. The calculated peak power was 0.161 watts total power.
   The worst-case total peak power spectral density provided a minimum margin of -12.8 dB below
   the requirements. The minimum margin harmonic radiated emission provided -0.4 dB margin
   below requirements. General radiated emissions of supporting equipment provided -11.5 dB
   margin. There were no other significantly measurable emissions in the restricted bands other
   than those recorded in this report. Other emissions were present with amplitudes at least 20 dB
   below the requirements. There were no other deviations or exceptions to the requirements.


   Statement of Modifications and Deviations

   No modifications to the EUT were required for the unit to demonstrate compliance with the
   47CFR Part 15C and Industry Canada RSS-247 emissions requirements. There were no
   deviations or modifications to the specifications.




Rogers Labs, Inc.                Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace            Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053              Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214        Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                       File: Mikrotik RB951UI2nD TstRpt 150901 Page 27 of 33


   NVLAP Lab Code 200087-0




   Annex

          Annex A Measurement Uncertainty Calculations

          Annex B Rogers Labs Test Equipment List

          Annex C Rogers Qualifications

          Annex D FCC Site Registration Letter

          Annex E Industry Canada Site Registration Letter




Rogers Labs, Inc.                   Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace               Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                 Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214           Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                          File: Mikrotik RB951UI2nD TstRpt 150901 Page 28 of 33


   NVLAP Lab Code 200087-0




   Annex A Measurement Uncertainty Calculations

   Measurement uncertainty calculations were made for the laboratory. Result of measurement
   uncertainty calculations are recorded below for AC line conducted and radiated emission
   measurements.

   Measurement Uncertainty                                        U(E)               U(lab)

   3 Meter Horizontal 30-200 MHz Measurements                     2.08               4.16

   3 Meter Vertical 30-200 MHz Measurements                       2.16               4.33

   3 Meter Vertical Measurements 200-1000 MHz                     2.99               5.97

   10 Meter Horizontal Measurements 30-200 MHz                    2.07               4.15

   10 Meter Vertical Measurements 30-200 MHz                      2.06               4.13

   10 Meter Horizontal Measurements 200-1000 MHz                  2.32               4.64

   10 Meter Vertical Measurements 200-1000 MHz                    2.33               4.66

   3 Meter Measurements 1-6 GHz                                   2.57               5.14

   3 Meter Measurements 6-18 GHz                                  2.58               5.16

   AC Line Conducted                                              1.72               3.43




Rogers Labs, Inc.               Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace           Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053             Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214       Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                      File: Mikrotik RB951UI2nD TstRpt 150901 Page 29 of 33


   NVLAP Lab Code 200087-0




   Annex B Rogers Labs Test Equipment List
   List of Test Equipment                                       Calibration   Date    Due
   Spectrum Analyzer: Rohde & Schwarz ESU40                                   5/15    5/16
   Spectrum Analyzer: HP 8562A, HP Adapters: 11518, 11519, and 11520          5/15    5/16
           Mixers: 11517A, 11970A, 11970K, 11970U, 11970V, 11970W
   Spectrum Analyzer: HP 8591EM                                               5/15    5/16
   Antenna: EMCO Biconilog Model: 3143                                        5/15    5/16
   Antenna: Sunol Biconilog Model: JB6                                        10/14   10/15
   Antenna: EMCO Log Periodic Model: 3147                                     10/14   10/15
   Antenna: Com Power Model: AH-118                                           10/14   10/16
   Antenna: Com Power Model: AH-840                                           5/15    5/17
   Antenna: Antenna Research Biconical Model: BCD 235                         10/14   10/15
   Antenna: EMCO 6509                                                         10/14   10/15
   LISN: Compliance Design Model: FCC-LISN-2.Mod.cd, 50 μHy/50 ohm/0.1 µf     10/14   10/15
   R.F. Preamp CPPA-102                                                       10/14   10/15
   Attenuator: HP Model: HP11509A                                             10/14   10/15
   Attenuator: Mini Circuits Model: CAT-3                                     10/14   10/15
   Attenuator: Mini Circuits Model: CAT-3                                     10/14   10/15
   Cable: Belden RG-58 (L1)                                                   10/14   10/15
   Cable: Belden RG-58 (L2)                                                   10/14   10/15
   Cable: Belden 8268 (L3)                                                    10/14   10/15
   Cable: Time Microwave: 4M-750HF290-750                                     10/14   10/15
   Cable: Time Microwave: 10M-750HF290-750                                    10/14   10/15
   Frequency Counter: Leader LDC825                                           2/15    2/16
   Oscilloscope Scope: Tektronix 2230                                         2/15    2/16
   Wattmeter: Bird 43 with Load Bird 8085                                     2/15    2/16
   Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140            2/15    2/16
   R.F. Generators: HP 606A, HP 8614A, HP 8640B                               2/15    2/16
   R.F. Power Amp 65W Model: 470-A-1010                                       2/15    2/16
   R.F. Power Amp 50W M185- 10-501                                            2/15    2/16
   R.F. Power Amp A.R. Model: 10W 1010M7                                      2/15    2/16
   R.F. Power Amp EIN Model: A301                                             2/15    2/16
   LISN: Compliance Eng. Model 240/20                                         2/15    2/16
   LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08             2/15    2/16
   Antenna: EMCO Dipole Set 3121C                                             2/15    2/16
   Antenna: C.D. B-101                                                        2/15    2/16
   Antenna: Solar 9229-1 & 9230-1                                             2/15    2/16
   Audio Oscillator: H.P. 201CD                                               2/15    2/16
   ELGAR Model: 1751                                                          2/15    2/16
   ELGAR Model: TG 704A-3D                                                    2/15    2/16
   ESD Test Set 2010i                                                         2/15    2/16
   Fast Transient Burst Generator Model: EFT/B-101                            2/15    2/16
   Field Intensity Meter: EFM-018                                             2/15    2/16
   KEYTEK Ecat Surge Generator                                                2/15    2/16

Rogers Labs, Inc.            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 30 of 33


   NVLAP Lab Code 200087-0




   Annex C Rogers Qualifications

   Scot D. Rogers, Engineer

   Rogers Labs, Inc.

   Mr. Rogers has approximately 17 years’ experience in the field of electronics. Engineering
   experience includes six years in the automated controls industry and remaining years working
   with the design, development and testing of radio communications and electronic equipment.

   Positions Held

                    Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

                    Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

                    Electrical Engineer:   Rogers Labs, Inc. Current

   Educational Background

   1)               Bachelor of Science Degree in Electrical Engineering from Kansas State University.

   2)               Bachelor of Science Degree in Business Administration Kansas State University.

   3)               Several Specialized Training courses and seminars pertaining to Microprocessors and
                    Software programming.



   Scot D. Rogers




Rogers Labs, Inc.                          Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace                      Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053                        Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214                  Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                                 File: Mikrotik RB951UI2nD TstRpt 150901 Page 31 of 33


   NVLAP Lab Code 200087-0




   Annex D FCC Site Registration Letter




Rogers Labs, Inc.            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 32 of 33


   NVLAP Lab Code 200087-0




   Annex E Industry Canada Site Registration Letter




Rogers Labs, Inc.            Mikrotikls SIA                          S/N: 5D4501DDA4E7/527
4405 W. 259th Terrace        Model: RB951Ui-2nD                      FCC ID#: TV7RB951UI-2ND
Louisburg, KS 66053          Test #: 150901                          IC: 7442A-9512ND
Phone/Fax: (913) 837-3214    Test to: 47CFR 15.247, RSS-247          Date: October 13, 2015
Revision 1                   File: Mikrotik RB951UI2nD TstRpt 150901 Page 33 of 33



Document Created: 2015-10-13 12:59:32
Document Modified: 2015-10-13 12:59:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC