RF Exposure Report

FCC ID: TV7OMNITIKPG5HACD

RF Exposure Info

Download: PDF
FCCID_3161312

            Company: MikroTik

Assessment of: MikroTik RBOmniTikPG-5HacD

  To: FCC CFR 47 §1.1310 Exposure Limits

         Report No.: MIKO51-MPE




           MPE TEST REPORT


                     MPE TEST REPORT
                                    FROM




       Assessment of: MikroTik RBOmniTikPG-5HacD
                                      to
          To: FCC CFR 47 §1.1310 Exposure Limits
Test Report Serial No.: MIKO51 - OmniTIK 5 PoE ac FCC IC EU
                  This report supersedes: NONE

                        Applicant:         MikroTik
                                           Aizkraukles iela 23
                                           Riga, LV 1006
                                           Latvia
             Product Function:             Wireless Access Point
                      Issue Date:          7th October 2016



        This Test Report is Issued Under the Authority of:

            MiCOM Labs, Inc.
            575 Boulder Court
            Pleasanton California 94566
            USA
            Phone: +1 (925) 462-0304
            Fax: +1 (925) 462-0306
            www.micomlabs.com

        MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                    Title:        MikroTik RBOmniTikPG-5HacD
                                                                      To:         FCC CFR 47 §1.1310 Exposure Limits
                                                                 Serial #:        MIKO51-MPE
                                                              Issue Date:         7th October 2016
                                                                   Page:          3 of 5




1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
                             2            2

EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)
Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is
           2
1.0 mW/cm


The calculations in the table below use the highest conducted power values together with the lowest
antenna gain specified for the EUT. These calculations represent worst case in terms of the exposure
levels.
                                                                   Calculated
                                              Peak        Peak                    Calculated Minimum
                      Ant      Numeric                                 Safe
    Freq. Band                              Output       Output                     Power      Separation
                      Gain      Gain                                 Distance
       (MHz)                                 Power       Power                    Density @ Distance
                     (dBi) (numeric)                                    @
                                             (dBm)        (mW)                2     20cm          (cm)
                                                                    1mW/cm
  5725.0 - 5850.0     7.50       5.62         25.99      396.90        13.33         0.44        20.00
 5150.0 – 5250.0      7.50       5.62         15.44        34.99        3.96          0.04                                      20.0
Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                                                    Title:        MikroTik RBOmniTikPG-5HacD
                                                                      To:         FCC CFR 47 §1.1310 Exposure Limits
                                                                 Serial #:        MIKO51-MPE
                                                              Issue Date:         7th October 2016
                                                                   Page:          4 of 5



Specification
Maximum Permissible Exposure Limits




                                        2
FCC §1.1310 Limit = 1mW / cm from 1.310 Table 1




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2017-12-16 00:06:14
Document Modified: 2017-12-16 00:06:14

© 2024 FCC.report