RF Exposure (MPE)

FCC ID: TV7LHG5ACD

RF Exposure Info

Download: PDF
FCCID_4458945

MPE/RF EXPOSURE EVALUATION REPORT

FCC Part 15 RF Exposure Requirements

Report No.: MIKO92_MPE FCC Rev A




                          Company: Mikrotikls SIA

                    Model: RBLHGG-5acD Wireless Module


MPE/RF EXPOSURE EVALUATION REPORT


                    Company: Mikrotikls SIA

           Model: RBLHGG-5acD Wireless Module


                 To: FCC CFR 47 Part 1.1310


      Test Report Serial No.: MIKO92_MPE FCC Rev A

                 This report supersedes: NONE


          Applicant:     Mikrotikls SIA
                         Brivibas gatve 214i
                         Riga, LV-1039
                         Latvia
   Product Function:     802.11ac WLAN access point


         Issue Date:     9th September 2019



    This Test Report is Issued Under the Authority of:

        MiCOM Labs, Inc.
        575 Boulder Court
        Pleasanton California 94566
        USA
        Phone: +1 (925) 462-0304
        Fax: +1 (925) 462-0306
        www.micomlabs.com

     MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                        Title:      Mikrotikls RBLHGG-5acD Wireless Module
                                                                          To:       FCC CFR 47 Part 1.1310
                                                                     Serial #:      MIKO92_MPE FCC Rev A




1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4*π*d2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

The calculations in the table below use the highest conducted power values together with the lowest antenna
gain specified for the EUT. The RBLHGG-5acD Wireless Module can only transmit on a single frequency
at any given time therefore the following calculations represent worst case exposure levels.

                                                                                                                              Calculated
                                                                                 Calculated                       Min
                                                     Peak            Peak                         Power                         Power
                           Ant       Numeric                                       Power                      Calculated
                                                    Output          Output                       Density                       Density
 Freq. Band (MHz)         Gain        Gain                                        Density                         safe
                                                    Power           Power                         Limit                       (mW/cm2)
                          (dBi)     (numeric)                                    (mW/cm2)                     distance for
                                                    (dBm)           (mW)                        (mW/cm2)                        @ Safe
                                                                                  @ 20cm                       Limit (cm)
                                                                                                                               Distance
  5250.0 - 5350.0         9.00         7.94          18.95          78.50           0.12           1.00            8.00           1.00
  5470.0 - 5725.0         9.00         7.94          16.87          48.68           0.08           1.00            6.00           1.00


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations
indicate the MPE distance to be less.


Specification - Maximum Permissible Exposure Limits

The Limit is defined in Table 1 of FCC §1.1310.




                 Issue Date:       9th September 2019                                          Page:      3 of 4
                This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                           personnel. All changes will be noted in the Document History section of the report.
    MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2019-10-29 23:14:47
Document Modified: 2019-10-29 23:14:47

© 2024 FCC.report