Test Report

FCC ID: TV7LDF2ND

Test Report

Download: PDF
FCCID_3934882

Testing
NVLAP Lab Code 200087-0




                Class 2 Permissive Change
                 Engineering Test Report
                                           FOR

               Model: RBLDF-2nD
                 2412-2462 MHz
     47CFR 15.247 and Industry Canada RSS-247
        License Exempt Intentional Radiator
       Broadband Digital Transmission System
              FCC ID: TV7LDF2ND
               IC: 7442A-LDF2ND
                                           FOR



                            Mikrotikls SIA
                                   Brivibas gatve 214i
                                  Riga Latvia LV-1039

                             Test Report Number: 180702
                              FCC Designation: US5305
                          IC Test Site Registration: 3041A-1

Authorized Signatory:
                          Scot D. Rogers




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 1 of 21


Testing
NVLAP Lab Code 200087-0




                            ROGERS LABS, INC.
                            4405 West 259th Terrace
                            Louisburg, KS 66053
                            Phone / Fax (913) 837-3214



                          Class 2 Permissive Change
                          Engineering Test Report For
                                                FOR
                  47 CFR, PART 15C - Intentional Radiators Paragraph 15.247
                            License Exempt Intentional Radiator
                                                 For

                                    Mikrotikls SIA
                                          Brivibas gatve 214i
                                         Riga Latvia LV-1039

                                    Model: RBLDF-2nD

                               Digital Transmission System
                                   Frequency Range 2412-2462 MHz
                                        FCC ID: TV7LDF2ND
                                         IC: 7442A-LDF2ND

Test Date: July 2, 2018

Certifying Engineer:
                           Scot D. Rogers
                           Rogers Labs, Inc.
                           4405 West 259th Terrace
                           Louisburg, KS 66053
                           Telephone/Facsimile: (913) 837-3214

This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government.


Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 2 of 21


 Testing
 NVLAP Lab Code 200087-0




Table Of Contents

TABLE OF CONTENTS .................................................................................................. 3

REVISIONS..................................................................................................................... 4

FORWARD ..................................................................................................................... 5

OPINION / INTERPRETATION OF RESULTS ............................................................... 5

CHANGE TO EQUIPMENT FROM ORIGINAL DESIGN ................................................ 5

EQUIPMENT TESTED .................................................................................................... 6

EQUIPMENT FUNCTION AND CONFIGURATION........................................................ 6

        Equipment Configuration....................................................................................................................................7

APPLICATION FOR CERTIFICATION ........................................................................... 8

APPLICABLE STANDARDS & TEST PROCEDURES .................................................. 9

EQUIPMENT TESTING PROCEDURES ........................................................................ 9

        Radiated Emission Test Procedure .....................................................................................................................9

           Diagram 1 Test arrangement for radiated emissions ......................................................................................... 10

           Diagram 2 Test arrangement for radiated emissions tested on Open Area Test Site (OATS) ........................... 11

TEST SITE LOCATIONS .............................................................................................. 11

LIST OF TEST EQUIPMENT ........................................................................................ 12

UNITS OF MEASUREMENTS ...................................................................................... 13

ENVIRONMENTAL CONDITIONS................................................................................ 13

STATEMENT OF MODIFICATIONS AND DEVIATIONS ............................................. 13

INTENTIONAL RADIATORS ........................................................................................ 13

        Antenna Requirements ...................................................................................................................................... 13

        Operation in the 2400-2483.5 MHz Frequency Band ...................................................................................... 14


Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 3 of 21


 Testing
 NVLAP Lab Code 200087-0



        Transmitter Emissions Data .............................................................................................................................. 15

           Table 1 Transmitter Radiated Emissions (Worst-case)...................................................................................... 15

        Summary of Results for Transmitter Radiated Emissions of Intentional Radiator ..................................... 16

STATEMENT OF MODIFICATIONS AND DEVIATIONS ............................................. 16

ANNEX .......................................................................................................................... 17

        Annex A Measurement Uncertainty Calculations ........................................................................................... 18

        Annex B Rogers Labs Test Equipment List ..................................................................................................... 19

        Annex C Rogers Qualifications ......................................................................................................................... 20

        Annex D Rogers Labs Certificate of Accreditation ......................................................................................... 21



Revisions
Revision 1 Issued July 17, 2018




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 4 of 21


Testing
NVLAP Lab Code 200087-0




Forward

The following information is submitted as documentation of compliance with regulations
supporting Class 2 Permissible Change of Authorized Equipment. This product was authorized
under Digital transmission system equipment per 47 CFR Paragraph 15.247, Industry Canada
RSS-247 Issue 2 and RSS-GEN, operating in the 2412 – 2462 MHz frequency band. The design
was originally Granted as a stand-alone product which contains an integral antenna. The product
authorization remains intact and this report documents using the product with an external
reflective dish antenna with increased gain. This Class 2 Permissible Change request documents
and supports demonstration of compliance when using the higher gain antenna system. The
product remains electrically identical as no modifications to the product were performed or
required.
               Name of Applicant:   Mikrotikls SIA
                                    Brivibas gatve 214i
                                    Riga Latvia LV-1039
               Model: RBLDF-2nD
               FCC ID: TV7LDF2ND                 IC: 7442A-LDF2ND
Opinion / Interpretation of Results

                            Tests Performed                      Results

    Radiated Emissions                                          Complies


Change to Equipment from Original Design
This request addresses use with a high gain dish style antenna. The information contained in this
report addresses radiated emissions measured when using the RBLDF-2nD mounted to a
parabolic dish antenna providing gain of 25 dBi. No modification in the transmitter circuitry was
required or performed. The transmitter remains electrically identical and functionally equivalent
to the original equipment authorization.




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 5 of 21


 Testing
 NVLAP Lab Code 200087-0




Equipment Tested
Equipment                  Model                        Serial Number             FCC I.D.
EUT                        RBLDF-2nD                    8D30082D7F29              TV7LDF2ND
Dish Antenna               DS2076                       DS10760219181246560029 N/A
AC Adapter                 MLF-A001224003380FE0141              N/A               N/A
Power Adapter              POE                          N/A                       N/A
Dell Studio XPS            921LBN1                      N/A                       N/A
Test results in this report relate only to the items tested.
Equipment Function and Configuration
The EUT is a 2412-2462 MHz (Dual Chain (2 Tx chains) Multiple Input Multiple Out
(MIMO) Digital Transmission System. The design provides operational capabilities across
the 2412-2462 MHz Digital Transmissions System. The EUT offers broadband wireless
connectivity to transmit and receive data. The design utilizes integral antenna system which
was attached to the external Parabolic Dish Antenna. The EUT provides single
communication interface port and requires power provided from Power Over Ethernet (POE)
adapter. The design requires power provided using the included POE (Power Over Ethernet)
adapter and AC/DC power supply. For testing purposes, the EUT was mounted on the Dish
antenna and the transceiver was communicating to the laptop computer through the Ethernet
network interface. The system was connected to and powered from the manufacturer
supplied POE and AC/DC power supply. This configuration provided operational control of
the EUT and communications over the network interface between the EUT and supporting
computer system. The design provides no other interfacing options than those presented in
this report. As requested by the manufacturer the equipment was tested for emissions
compliance using the available configuration with the worst-case data presented. Test results
in this report relate only to the products described in this report.




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 6 of 21


Testing
NVLAP Lab Code 200087-0




Equipment Configuration




                                     (EUT)



                               Network Connection




                                                POE Input

                                                            Laptop Computer (CPU)

                          AC/DC Adapter




                                                            CPU AC Power Adapter
                                     Utility Power




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 7 of 21


Testing
NVLAP Lab Code 200087-0




Application for Certification
(1)            Manufacturer:          Mikrotikls SIA
                                      Brivibas gatve 214i
                                      Riga Latvia LV-1039
(2)            Identification: Model: RBLDF-2nD
               FCC I.D.: TV7LDF2ND           IC: 7442A-LDF2ND
(3)            Instruction Book:
               Refer to Exhibit for Instruction Manual.
(4)            Description of Circuit Functions:
               Refer to Exhibit of Operational Description.
(5)            Block Diagram with Frequencies:
               Refer to Exhibit of Operational Description.
(6)            Report of Measurements:
               Report of measurements follows in this Report.
(7)            Photographs: Construction, Component Placement, etc.:
               Refer to Exhibit for photographs of equipment.
(8)            List of Peripheral Equipment Necessary for operation. The equipment operates from power
               received from authorized AC/DC power adapter and POE. The EUT provides single
               Ethernet port for communications and power. During testing, the EUT was powered from
               the POE and AC/DC power supply and connected to CPU through a network cable.
(9)            Transition Provisions of 47CFR 15.37 are not requested
(10)           Not Applicable. The unit is not a scanning receiver.
(11)           Not Applicable. The EUT does not operate in the 59 – 64 GHz frequency band.
(12)           The equipment is not software defined and this section is not applicable.
(13)           Applications for certification of U-NII devices in the 5.15-5.35 GHz and the 5.47-5.85
               GHz bands must include a high-level operational description of the security procedures
               that control the radio frequency operating parameters and ensure that unauthorized
               modifications cannot be made. Not applicable to this filing.
(14)           Contain at least one drawing or photograph showing the test set-up for each of the
               required types of tests applicable to the device for which certification is requested. These
               drawings or photographs must show enough detail to confirm other information
               contained in the test report. Any photographs used must be focused originals without
               glare or dark spots and must clearly show the test configuration used. This information is
               provided in this report and Test Setup Exhibits provided with the application filing.



Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 8 of 21


Testing
NVLAP Lab Code 200087-0




Applicable Standards & Test Procedures

In accordance with the Federal Communications Code of Federal Regulations, Title 47 (47CFR)
dated July 2, 2018: Part 2, Subpart J, Paragraphs 2.1043, applicable parts of paragraph 15C,
KDB 178919 D01 Permissive Change Policy v06, Industry Canada RSP-100 Issue 11, RSS-247
Issue 2, and RSS-GEN Issue 5 operation in the 2400 – 2483.5 MHz Frequency band. Test
procedures used are the established Methods of Measurement of Radio-Noise Emissions as
described in ANSI C63.10-2013.


Equipment Testing Procedures

Radiated Emission Test Procedure
The EUT was placed on a rotating 0.9 x 1.2-meter platform, elevated as required above the
ground plane at a distance of 3 meters from the FSM antenna. Radiated emissions testing was
performed as required in the regulations and specified in ANSI C63.10-2013. EMI energy was
maximized by equipment placement permitting orientation in three orthogonal axes, raising and
lowering the FSM antenna, changing the antenna polarization, and by rotating the turntable.
Each emission was maximized before data was taken and recorded. The frequency spectrum
from 9 kHz to 25,000 MHz was searched for emissions during preliminary investigation. Refer
to diagrams one and two showing typical test setup. Refer to photographs in the test setup
exhibits for specific EUT placement during testing.




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 9 of 21


Testing
NVLAP Lab Code 200087-0




1—A LISN is optional for radiated measurements between 30 MHz and 1000 MHz but not
allowed for measurements below 30 MHz and above 1000 MHz (see 6.3.1). If used, then connect
EUT to one LISN. Unused LISN measuring port connectors shall be terminated in 50 Ω loads.
The LISN may be placed on top of, or immediately beneath, the reference ground plane (see
6.2.2 and 6.2.3.2).
1.1—LISN spaced at least 80 cm from the nearest part of the EUT chassis.
2—Antenna can be integral or detachable, depending on the EUT (see 6.3.1).
3—Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 cm to 40 cm long (see 6.3.1).
4—For emission measurements at or below 1 GHz, the table height shall be 80 cm. For emission
measurements above 1 GHz, the table height shall be 1.5 m for measurements, except as
otherwise specified (see 6.3.1 and 6.6.3.1).
Diagram 1 Test arrangement for radiated emissions


Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 10 of 21


Testing
NVLAP Lab Code 200087-0




                                                        Appropriate
                                                        Frequency
                                                        Dependent
                                                        Antenna




                               0.8 – 1.5 m




                        Radiated Emissions (9 kHz-30 MHz)
             RBW                     Video. BW               Detector Function
            9 kHz                      30 kHz                 Peak / Average
                        Radiated Emissions (30-1000 MHz)
             RBW                     Video. BW               Detector Function
           120 kHz                    300 kHz                Peak / Quasi Peak
                       Radiated Emissions (Above 1000 MHz)
             RBW                     Video BW                Detector Function
           100 kHz                    100 kHz                       Peak
            1 MHz                      1 MHz                  Peak / Average
Diagram 2 Test arrangement for radiated emissions tested on Open Area Test Site (OATS)
Test Site Locations
Antenna Port Conducted           Antenna Port conducted emissions testing performed in a shielded
                          screen room located at Rogers Labs, Inc., 4405 West 259th Terrace,
                          Louisburg, KS

Radiated EMI              The radiated emissions tests were performed at the 3 meters, Open Area
                          Test Site (OATS) located at Rogers Labs, Inc., 4405 West 259th Terrace,
                          Louisburg, KS

Site Registration         FCC Site Designation US5305, Industry Canada Registration: 3041A-1

NVLAP Accreditation              Lab code 200087-0

Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 11 of 21


Testing
NVLAP Lab Code 200087-0




List of Test Equipment
Equipment      Manufacturer        Model (SN)                Band        Cal Date(m/d/y) Due
☐ LISN         FCC        FCC-LISN-50-2-10(1PA) (160611) .15-30MHz         5/2/2018     5/2/2019
☐ LISN         Compliance Design FCC-LISN-2.Mod.cd,          .15-30MHz     10/24/2017 10/24/2018
☒ Cable        Huber & Suhner Inc. Sucoflex102ea(L10M)(303073)9kHz-40 GHz 10/24/2017 10/24/2018
☒ Cable        Huber & Suhner Inc. Sucoflex102ea(1.5M)(303069)9kHz-40 GHz 10/24/2017 10/24/2018
☐ Cable        Huber & Suhner Inc. Sucoflex102ea(1.5M)(303071)9kHz-40 GHz 10/24/2017 10/24/2018
☐ Cable        Belden              RG-58 (L1-CAT3-11509) 9kHz-30 MHz 10/24/2017 10/24/2018
☐ Cable        Belden              RG-58 (L2-CAT3-11509) 9kHz-30 MHz 10/24/2017 10/24/2018
☐ Antenna      ARA                 BCD-235-B (169)           20-350MHz     10/24/2017 10/24/2018
☐ Antenna      EMCO                3147 (40582)              200-1000MHz 10/24/2017 10/24/2018
☒ Antenna      ETS-Lindgren        3117 (200389)             1-18 GHz      5/2/2018     5/2/2020
☐ Antenna      Com Power           AH-118 (10110)            1-18 GHz      10/24/2017 10/24/2019
☒ Antenna      Com Power           AH-840 (101046)           18-40 GHz     5/15/2017 5/15/2019
☒ Antenna      Com Power           AL-130 (121055)           .001-30 MHz   10/24/2017 10/24/2018
☒ Antenna      Sunol               JB-6 (A100709)            30-1000 MHz 10/24/2017 10/24/2018
☒ Analyzer     Rohde & Schwarz ESU40 (100108)                20Hz-40GHz    5/2/2018     5/2/2019
☐ Analyzer     Rohde & Schwarz ESW44 (101534)                20Hz-44GHz    12/22/2017 12/22/2018
☐ Analyzer     Rohde & Schwarz FS-Z60, 90, 140, and 220      40GHz-220GHz 12/22/2017 12/22/2019
☐ Analyzer     HP                  8591EM (3628A00871)       9kHz-1.8GHz 5/2/2018       5/2/2019
☐ Analyzer     HP                  8562A (3051A05950)        9kHz-125GHz 5/2/2018       5/2/2019
☐ Analyzer     HP External Mixers11571, 11970                25GHz-110GHz 5/2/2018      5/2/2019
☒ Amplifier Com-Power              PA-010 (171003)           100Hz-30MHz 10/24/2017 10/24/2018
☒ Amplifier Com-Power              CPPA-102 (01254)          1-1000 MHz    10/24/2017 10/24/2018
☒ Amplifier Com-Power              PAM-118A (551014)         0.5-18 GHz    10/24/2017 10/24/2018
☐ Power Meter Agilent              N1911A with N1921A        0.05-40 GHz   5/2/2018     5/2/2019
☐ Generator Rohde & Schwarz SMB100A6 (100150)                20Hz-6 GHz    5/2/2018     5/2/2019
☐ Generator Rohde & Schwarz SMBV100A6 (260771)               20Hz-6 GHz    5/2/2018     5/2/2019
☐ RF Filter    Micro-Tronics       BRC50722 (009).9G notch 30-1800 MHz 5/2/2018         5/2/2019
☐ RF Filter    Micro-Tronics       HPM50114 (017)1.5G HPF 30-18000 MHz 5/2/2018         5/2/2019
☐ RF Filter    Micro-Tronics       HPM50117 (063) 3G HPF 30-18000 MHz 5/2/2018          5/2/2019
☐ RF Filter    Micro-Tronics       HPM50105 (059) 6G HPF 30-18000 MHz 5/2/2018          5/2/2019
☐ RF Filter    Micro-Tronics       BRM50702 (172) 2G notch 30-1800 MHz 5/2/2018         5/2/2019
☐ RF Filter    Micro-Tronics       BRC50703 (G102) 5G notch 30-1800 MHz 5/2/2018        5/2/2019
☐ RF Filter    Micro-Tronics       BRC50705 (024) 5G notch 30-1800 MHz 5/2/2018         5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (1735)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (1436)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (14362)          30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (1445)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (14452)          30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-6W2+ (1438)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-6W2+ (1736)           30-6000 MHz 5/2/2018       5/2/2019
☒ Weather station Davis            6312 (A70927D44N)                       10/24/2017 10/24/2018

Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 12 of 21


 Testing
 NVLAP Lab Code 200087-0




Units of Measurements
Conducted EMI                     Data is in dBµV; dB referenced to one microvolt
Radiated EMI                      Data is in dBµV/m; dB/m referenced to one microvolt per meter
Sample Calculation:
                           RFS = Radiated Field Strength, FSM = Field Strength Measured
                           A.F. = Receive antenna factor, Gain = amplification gains and/or cable losses
                           RFS (dBµV/m @ 3m) = FSM (dBµV) + A.F. (dB) - Gain (dB)
Environmental Conditions

Ambient Temperature                      23.3° C

Relative Humidity                        38%

Atmospheric Pressure                     1015.6 mb



Statement of Modifications and Deviations

No modifications to the EUT were required during investigation for the equipment to
demonstrate compliance with the 47CFR, Part 2.1043, Part 15C, Industry Canada RSS-247 Issue
2, and RSS-GEN Issue 5 emission requirements. There were no deviations to the specifications.


Intentional Radiators

The following information is submitted in support of demonstration of compliance with the
requirements of 47CFR Parts 2 and 15C, Class 2 permissible change, Industry Canada RSP-100
Issue 11, RSS-247 Issue 2 and RSS-GEN Issue 5.

Antenna Requirements

The EUT incorporates integral antenna system. The design may optionally be placed on the
external Parabolic Dish documented in this report which provides higher gain and directivity.
The antenna connection point complies with the unique antenna connection requirements. The
unique antenna connection requirements are fulfilled. There are no deviations or exceptions to
the specification.


Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 13 of 21


Testing
NVLAP Lab Code 200087-0




Operation in the 2400-2483.5 MHz Frequency Band
Radiated emissions were measured on the Open Area Test Site (OATS) at a three-meter
distance. The production design RBLDF-2nD was mounted to the dish antenna during
testing. Radiated emissions measurements were performed on the described configuration.
Testing procedures defined in publication ANSI C63.10-2013 was used during compliance
testing. The EUT was placed on a turntable elevated as required above the ground plane at a
distance of 3 meters from the FSM antenna located on the OATS. The peak and quasi-peak
amplitude of the frequencies below 1000 MHz were measured using a spectrum analyzer /
EMC receiver. The peak and average amplitude of emissions above 1000 MHz were
measured using a spectrum analyzer / EMC receiver. Emissions data was recorded from the
measurement results. Data presented reflects measurement result corrected to account for
measurement system gains and losses.




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 14 of 21


Testing
NVLAP Lab Code 200087-0




Transmitter Emissions Data
Table 1 Transmitter Radiated Emissions (Worst-case)
       Frequency in         Horizontal       Horizontal      Vertical Peak   Vertical Average   Limit @ 3m
          MHz             Peak (dBµV/m)   Average (dBµV/m)    (dBµV/m)          (dBµV/m)         (dBµV/m)

            2412.0           106.1             102.6            105.1            101.9              -

            4824.0            51.4             44.2             49.5              39.7            54.0

            7236.0            50.7             38.0             51.0              38.0            54.0

            9648.0            53.2             40.9             53.3              40.5            54.0

          12060.0             56.2             43.4             56.1              43.2            54.0

          14472.0             57.9             45.3             58.8              45.1            54.0

          16884.0             60.0             47.6             60.4              47.0            54.0

            2437.0           106.0             102.8            105.2            102.0              -

            4874.0            50.2             40.9             48.1              36.5            54.0

            7311.0            51.1             38.4             51.2              38.4            54.0

            9748.0            52.7             40.1             53.3              40.0            54.0

          12185.0             57.6             44.9             57.9              44.8            54.0

          14622.0             59.7             46.5             59.2              46.3            54.0

          17059.0             61.2             48.6             61.4              48.6            54.0

            2462.0           107.1             103.9            105.6            102.3              -

            4924.0            49.1             38.9             47.1              34.5            54.0

            7386.0            51.7             38.4             51.2              38.4            54.0

            9848.0            52.7             40.3             53.1              40.4            54.0

          12310.0             57.9             45.0             57.8              44.9            54.0

          14772.0             58.1             45.7             58.3              45.6            54.0

          17234.0             61.4             48.4             61.1              48.3            54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.


Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 15 of 21


Testing
NVLAP Lab Code 200087-0




Summary of Results for Transmitter Radiated Emissions of Intentional Radiator

The EUT demonstrated compliance with the radiated emissions requirements of 47CFR Part
15.247 and Industry Canada RSS-247. The minimum radiated harmonic emission provided -5.4
dB margin below requirements. There were no other significantly measurable emissions in the
restricted bands other than those recorded in this report. Other emissions were present with
amplitudes at least 20 dB below the requirements. There were no other deviations or exceptions
to the requirements.


Statement of Modifications and Deviations

No modifications to the EUT were required for the unit to demonstrate compliance with the
47CFR Part 15C paragraph 15.247 and Industry Canada RSS-247 emissions requirements.
There were no deviations or modifications to the specifications.




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 16 of 21


Testing
NVLAP Lab Code 200087-0




Annex

                          •   Annex A Measurement Uncertainty Calculations

                          •   Annex B Rogers Labs Test Equipment List

                          •   Annex C Rogers Qualifications

                          •   Annex D Certificate of Accreditation




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 17 of 21


Testing
NVLAP Lab Code 200087-0




Annex A Measurement Uncertainty Calculations

The measurement uncertainty was calculated for all measurements listed in this test report
according To CISPR 16–4. Result of measurement uncertainty calculations are recorded below.
Component and process variability of production devices similar to those tested may result in
additional deviations. The manufacturer has the sole responsibility of continued compliance.



                          Measurement                    Expanded Measurement
                                                            Uncertainty U(lab)

 3 Meter Horizontal 0.009-1000 MHz Measurements                    4.16

 3 Meter Vertical 0.009-1000 MHz Measurements                      4.33

 3 Meter Measurements 1-18 GHz                                     5.14

 3 Meter Measurements 18-40 GHz                                    5.16

 10 Meter Horizontal Measurements 0.009-1000 MHz                   4.15

 10 Meter Vertical Measurements 0.009-1000 MHz                     4.32

 AC Line Conducted                                                 1.75

 Antenna Port Conducted power                                      1.17

 Frequency Stability                                             1.00E-11

 Temperature                                                      1.6˚C

 Humidity                                                           3%




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 18 of 21


Testing
NVLAP Lab Code 200087-0




Annex B Rogers Labs Test Equipment List

List of Test Equipment                                    Calibration   Date (m/d/y)   Due
Antenna: Schwarzbeck Model: BBA 9106/VHBB 9124 (9124-627)               5/2/2018       5/2/2019
Antenna: Schwarzbeck Model: VULP 9118 A (VULP 9118 A-534)               5/2/2018       5/2/2019
Antenna: EMCO 6509                                                      10/24/2016     10/24/2018
Antenna: EMCO 3143 (9607-1277) 20-1200 MHz                              5/2/2018       5/2/2019
Antenna: EMCO Dipole Set 3121C                                          2/23/2018      2/23/2019
Antenna: C.D. B-101                                                     2/23/2018      2/23/2019
Antenna: Solar 9229-1 & 9230-1                                          2/23/2018      2/23/2019
Cable: Belden 8268 (L3)                                                 10/24/2017     10/24/2018
Cable: Time Microwave: 4M-750HF290-750                                  10/24/2017     10/24/2018
Frequency Counter: Leader LDC-825 (8060153                              5/2/2018       5/2/2019
Oscilloscope Scope: Tektronix 2230                                      2/23/2018      2/23/2019
Wattmeter: Bird 43 with Load Bird 8085                                  2/23/2018      2/23/2019
Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140         2/23/2018      2/23/2019
R.F. Generator: SMB100A6 s/n 100623                                     5/2/2018       5/2/2019
R.F. Generator: SBMBV100A s/n: 260771                                   5/2/2018       5/2/2019
R.F. Generators: HP 606A, HP 8614A, HP 8640B                            2/23/2018      2/23/2019
R.F. Power Amp 65W Model: 470-A-1010                                    2/23/2018      2/23/2019
R.F. Power Amp 50W M185- 10-501                                         2/23/2018      2/23/2019
R.F. Power Amp A.R. Model: 10W 1010M7                                   2/23/2018      2/23/2019
R.F. Power Amp EIN Model: A301                                          2/23/2018      2/23/2019
LISN: Compliance Eng. Model 240/20                                      5/2/2018       15/50/19
LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08          5/2/2018       5/2/2019
Audio Oscillator: H.P. 201CD                                            2/23/2018      2/23/2019
ESD Test Set 2010i                                                      2/23/2018      2/23/2019
Oscilloscope Scope: Tektronix MDO 4104                                  2/23/2018      2/23/2019
EMC Transient Generator HVT TR 3000                                     2/23/2018      2/23/2019
AC Power Source (Ametech, California Instruments)                       2/23/2018      2/23/2019
Fast Transient Burst Generator Model: EFT/B-101                         2/23/2018      2/23/2019
Field Intensity Meter: EFM-018                                          2/23/2018      2/23/2019
KEYTEK Ecat Surge Generator                                             2/23/2018      2/23/2019
ESD Simulator: MZ-15                                                    2/23/2018      2/23/2019
Shielded Room not required




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 19 of 21


Testing
NVLAP Lab Code 200087-0




Annex C Rogers Qualifications

Scot D. Rogers, Engineer

Rogers Labs, Inc.

Mr. Rogers has approximately 27 years’ experience in the field of electronics. Engineering
experience includes six years in the automated controls industry and remaining years working
with the design, development and testing of radio communications and electronic equipment.

Positions Held

               Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

               Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

               Electrical Engineer:   Rogers Labs, Inc. Current

Educational Background

1)             Bachelor of Science Degree in Electrical Engineering from Kansas State University.

2)             Bachelor of Science Degree in Business Administration Kansas State University.

3)             Several Specialized Training courses and seminars pertaining to Microprocessors and
               Software programming.



Scot D. Rogers




Rogers Labs, Inc.           Mikrotikls SIA     S/N: 8D30082D7F29, 8D3008BD1801
4405 W. 259th Terrace       Model: RBLDF-2nD                FCC ID: TV7LDF2ND
Louisburg, KS 66053         Test #: 180702                  IC: 7442A-LDF2ND
Phone/Fax: (913) 837-3214 Test to: CFR47 15C                Date: July 17, 2018
Revision 1           File: Mikrotik RBLDF2 C2PC TstRpt 180702      Page 20 of 21


NVlad)



                            United States Department of Commerce
                        National Institute of Standards and Technology




                                               viad
    Certificate of Accreditation to ISO/IEC 17025:2005

                                          NVLAP LAB CODE: 200087—0

                                                Rogers Labs, Inc.
                                                     Louisburg, KS


              is accredited by the National Voluntary Laboratory Accreditation Program for specific services,
                                          listed on the Scope of Accreditation, for:

                  Electromagnetic Compatibility & Telecommunications
            This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005.
         This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality
                        management system (refer to joint ISO—ILAC—IAF Communique dated January 2009).

                                                          *.E_fi‘l'
                                                               OF


                                                                                 mcJ\._,;
         2018—02—21 through 2019—03—31
                  Effective Dates                                           For the National Vflruntéty_I:bbflramqficcredflamnProgram
                                                                                    Sz



Document Created: 2018-07-17 16:08:14
Document Modified: 2018-07-17 16:08:14

© 2024 FCC.report