RF_exposure_report

FCC ID: TV7D25-5HPQ2HP

RF Exposure Info

Download: PDF
FCCID_4296051

MPE/RF EXPOSURE REPORT




                 Company: Mikrotikls SIA (MikroTik)

             Evaluation of: RBD25G-5HPacQD2HPnD-US

                    To: FCC CFR 47 Part 1.1310

         Report No.: MIKO81 RBD25G-5HPacQD2HPnD-US FCC
                             MPE Rev A


               MPE/RF EXPOSURE REPORT
                                        FROM




Evaluation of: Mikrotikls SIA (MikroTik) RBD25G-5HPacQD2HPnD-US (Audience)

                         To: FCC CFR 47 Part 1.1310

  Report Serial No.: MIKO81 RBD25G-5HPacQD2HPnD-US FCC MPE Rev A

                         This report supersedes: NONE

                           Applicant:        Mikrotikls SIA (MikroTik)
                                             Brivibas gatve 214i
                                             Riga, LV-1039
                                             Latvia

                  Product Function:          802.11a/b/g/n/ac WLAN router + LTE
                                             Customer Premises Equipment

                         Issue Date:         21st May 2019


            This Report is Issued Under the Authority of:

               MiCOM Labs, Inc.
               575 Boulder Court
               Pleasanton California 94566
               USA
               Phone: +1 (925) 462-0304
               Fax: +1 (925) 462-0306
               www.micomlabs.com

             MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                           Title:       MikroTik RBD25G-5HPacQD2HPnD-US
                                                                             To:        FCC CFR 47 Part 1.1310
                                                                        Serial #:       MIKO81 Audience Kit FCC MPE Rev A




1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
                             2           2
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

The calculations in the table below use the highest conducted power values together with the antenna gain
specified for the EUT. These calculations represent worst case in terms of the exposure levels.
                                                                                 Calculated
                                                     Peak            Peak                         Power
                           Ant       Numeric                                       Power
                                                    Output          Output                       Density         Min Calculated safe
 Freq. Band (MHz)         Gain        Gain                                        Density
                                                    Power           Power                         Limit         distance for Limit (cm)
                          (dBi)     (numeric)                                    (mW/cm2)
                                                    (dBm)           (mW)                        (mW/cm2)
                                                                                  @ 20cm
  5150.0 - 5250.0         2.50         1.78          27.53          566.24          0.200          1.00                   8.951
  2400.0 - 2483.5         3.50         2.24           19.5          89.13           0.040          1.00                   3.985
  5725.0 - 5850.0         4.50         2.82          26.57          453.94          0.255          1.00                  10.090


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations
indicate the MPE distance to be less.

Specification - Maximum Permissible Exposure Limits

The Limit is defined in Table 1 of FCC §1.1310.




                 Issue Date:       21st May 2019                                               Page:      3 of 4
                  This Report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.
    MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2019-05-28 07:54:02
Document Modified: 2019-05-28 07:54:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC