Test Report

FCC ID: TUVMSEA

Test Report

Download: PDF
FCCID_615822

                                                                                                  Page 1 of 25




                                   FCC CERTIFICATION
                                        On Behalf of
                             Eastern Times Technology Co., Ltd.

                                   Wireless Optical Mouse
                                   Model No.: DS-2121

                                     FCC ID: TUVMSEA




            Prepared for      :   Eastern Times Technology Co., Ltd.
            Address           :   Building 5, Penghua Industry Park, Heping Rd.(W),
                                  Longhua, Shenzhen, Guangdong, P.R. China

            Prepared by       :   ACCURATE TECHNOLOGY CO. LTD
            Address           :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                  Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                  P.R. China

                                  Tel: (0755) 26503290
                                  Fax: (0755) 26503396




            Report Number     :   ATE20052250
            Date of Test      :   December 12, 2005
            Date of Report    :   December 16, 2005




FCC ID: TUVMSEA                                          ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                                                                           Page 2 of 25




                                                              TABLE OF CONTENTS

     Description                                                                                                                                                 Page
     Test Report Certification
     1.      GENERAL INFORMATION .......................................................................................................... 4
          1.1.      Description of Device (EUT)....................................................................................................................4
          1.2.      Description of Test Facility ......................................................................................................................4
          1.3.      Measurement Uncertainty.........................................................................................................................4
     2.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 5
     3.      CONDUCTED EMISSION FOR FCC PART 15 SECTION 15.207(A) ...................................... 6
          3.1.      Block Diagram of Test Setup....................................................................................................................6
          3.2.      The Emission Limit For Section 15.207(a) ..............................................................................................6
          3.3.      EUT Configuration on Measurement .......................................................................................................7
          3.4.      Operating Condition of EUT ....................................................................................................................7
          3.5.      Test Procedure ..........................................................................................................................................7
          3.6.      Power Line Conducted Emission Measurement Results ..........................................................................8
     4.      RADIATED EMISSION FOR FCC PART 15 SECTION 15.227(B)........................................... 9
          4.1.      Block Diagram of Test Setup....................................................................................................................9
          4.2.      The Field Strength of Radiation Emission Measurement Limits..............................................................9
          4.3.      Configuration of EUT on Measurement .................................................................................................10
          4.4.      Operating Condition of EUT ..................................................................................................................10
          4.5.      Test Procedure ........................................................................................................................................10
          4.6.      The Field Strength of Radiation Emission Measurement Results ..........................................................11
     5.      FUNDAMENTAL RADIATED EMISSION FOR FCC PART 15 SECTION 15.227(A) ........ 13
          5.1.      Block Diagram of Test Setup..................................................................................................................13
          5.2.      The Emission Limit For Section 15.227(a) ............................................................................................13
          5.3.      EUT Configuration on Measurement .....................................................................................................14
          5.4.      Operating Condition of EUT ..................................................................................................................14
          5.5.      Test Procedure ........................................................................................................................................14
          5.6.      The Emission Measurement Result ........................................................................................................15
     6.      BAND EDGES ................................................................................................................................. 16
          6.1.      The Requirement ....................................................................................................................................16
          6.2.      EUT Configuration on Measurement .....................................................................................................16
          6.3.      Operating Condition of EUT ..................................................................................................................16
          6.4.      Test Procedure ........................................................................................................................................16
          6.5.      The Measurement Result ........................................................................................................................17
           APPENDIX I ( TEST CURVES) (7pages)




FCC ID: TUVMSEA                                                                              ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                      Page 3 of 25




                                      Test Report Certification

             Applicant          :   Eastern Times Technology Co., Ltd.
             Manufacturer       :   Eastern Times Technology Co., Ltd.
             EUT Description    :   Wireless Optical Mouse
                                     (A) MODEL NO.: DS-2121
                                     (B) SERIAL NO.: N/A
                                     (C) POWER SUPPLY: 2.4V DC (“AAA” batteries 2×)

             Measurement Procedure Used:

             FCC Rules and Regulations Part 15 Subpart C Section 15.227: 2004 & ANSI C63.4: 2003

             The device described above is tested by ACCURATE TECHNOLOGY CO. LTD to determine
             the maximum emission levels emanating from the device. The maximum emission levels are
             compared to the FCC Part 15 Subpart C Section 15.227 limits. The measurement results are
             contained in this test report and ACCURATE TECHNOLOGY CO. LTD is assumed full
             responsibility for the accuracy and completeness of these measurements. Also, this report shows
             that the Equipment Under Test (EUT) is to be technically compliant with the FCC requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of ACCURATE TECHNOLOGY CO. LTD.

             Date of Test :                                       December 16, 2005


             Prepared by :


                                                                      (Engineer)


             Reviewer :

                                                                  (Quality Manager)

             Approved & Authorized Signer :

                                                                      (Manager)




FCC ID: TUVMSEA                                              ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                      Page 4 of 25




          1. GENERAL INFORMATION


                  1.1.Description of Device (EUT)
                    EUT                     :   Wireless Optical Mouse

                    Model Number            :   DS-2121


                    Power Supply            :   2.4V DC (“AAA” batteries 2×), Can use USB cable to
                                                charge

                    Applicant               :   Eastern Times Technology Co., Ltd.
                    Address                 :   Building 5, Penghua Industry Park, Heping Rd.(W),
                                                Longhua, Shenzhen, Guangdong, P.R. China

                    Manufacturer            :   Eastern Times Technology Co., Ltd.
                    Address                 :   Building 5, Penghua Industry Park, Heping Rd.(W),
                                                Longhua, Shenzhen, Guangdong, P.R. China

                    Date of sample received :   December 12, 2005

                    Date of Test            :   December 16, 2005


                  1.2.Description of Test Facility
                    EMC Lab                 :   Accredited by TUV Rheinland Shenzhen, May 10, 2004

                                                Accredited by FCC, May 10, 2004
                                                The Certificate Registration Number is 253065

                                                Accredited by Industry Canada, May 18, 2004
                                                The Certificate Registration Number is IC 5077

                    Name of Firm            :   ACCURATE TECHNOLOGY CO. LTD
                    Site Location           :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                                Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                                P.R. China


                  1.3.Measurement Uncertainty
                    Conducted Emission Uncertainty =      ±2.66dB

                    Radiated Emission Uncertainty     =   ±4.26dB



FCC ID: TUVMSEA                                              ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                   Page 5 of 25




          2. MEASURING DEVICE AND TEST EQUIPMENT
                  Table 1: List of Test and Measurement Equipment
                   Kind of equipment Manufacturer      Type            S/N               Calibrated until
                   EMI Test Receiver Rohde&Schwarz     ESCS30          100307            12.16.2006
                   EMI Test Receiver Rohde&Schwarz     ESI26           838786/013        12.16.2006
                   Loop Antenna       Schwarzbeck      FMZB1516        113               12.16.2006
                   Bilog Antenna      Chase            CBL6112B        2591              12.16.2006
                   Spectrum Analyzer Anritsu           MS2651B         6200238856        12.16.2006
                   Pre-Amplifier      Agilent          8447D           2944A10619        12.16.2006
                   L.I.S.N.           Rohde&Schwarz    ESH3-Z5         100305            12.16.2006
                   L.I.S.N.           Rohde&Schwarz    ESH3-Z5         100310            12.16.2006
                   Signal Generator   GW               GAG-810         0913317           12.16.2006




FCC ID: TUVMSEA                                           ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                        Page 6 of 25




          3. CONDUCTED EMISSION FOR FCC PART 15 SECTION

              15.207(A)


                  3.1.Block Diagram of Test Setup
                        3.1.1.Block diagram of connection between the EUT and simulators

                                                     EUT             PC

                                     (EUT: Wireless Optical Mouse)

                        3.1.2. Shielding Room Test Setup Diagram




                                    (EUT: Wireless Optical Mouse)


                  3.2.The Emission Limit For Section 15.207(a)
                     6.2.1 Radiation Emission Measurement Limits According to Section 15.207(a)
                       Frequency                          Conducted Limit (dBμV)

                        (MHz)                    Quasi-peak                     Average
                       0.15 – 0.5                 66 to 56*                     56 to 46*
                         0.5 - 5                     56                            46
                         5 - 30                      60                            50
                     * Decreases with the logarithm of the frequency.



FCC ID: TUVMSEA                                                ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                       Page 7 of 25




                  3.3.EUT Configuration on Measurement
                     The following equipment are installed on the emission Measurement to meet the
                     commission requirements and operating regulations in a manner which tends to maximize
                     its emission characteristics in normal application.
                        3.3.1. Wireless Optical Mouse (EUT)
                             Model Number      :   DS-2121
                             Serial Number     :   N/A
                             Manufacturer      :   Eastern Times Technology Co., Ltd.


                  3.4.Operating Condition of EUT
                        3.4.1.Setup the EUT and simulator as shown as Section 6.1.

                        3.4.2.Turn on the power of all equipment.

                        3.4.3. Let the EUT work in Charge modes (use USB cable connect to PC) measure it.




                  3.5.Test Procedure
                     The EUT is put on the plane 0.8m high above the ground by insulating support and is
                     connected to the power mains through a line impedance stabilization network (L.I.S.N.).
                     This provides a 50ohm coupling impedance for the EUT system. Please refer the block
                     diagram of the test setup and photographs. Both sides of AC lines are checked to find out
                     the maximum conducted emission. In order to find the maximum emission levels, the
                     relative positions of equipment and all of the interface cables shall be changed according
                     to ANSI C63.4: 2003 on Conducted Emission Measurement.

                     The bandwidth of test receiver (R & S ESCS30) is set at 9kHz.

                     The frequency range from 150kHz to 30MHz is checked.

                     All the scanning waveforms are attached in Appendix I.




FCC ID: TUVMSEA                                               ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                     Page 8 of 25




                  3.6.Power Line Conducted Emission Measurement Results

                       PASS.

                       The frequency range from 150kHz to 30MHz is checked.


         Date of Test:    December 19, 2005                 Temperature:         22oC
         EUT:             Wireless Optical Mouse            Humidity:            50%
         Model No.:       DS-2121                           Power Supply:        120V a.c./60Hz
         Test Mode:       Charge                            Test Engineer:       Pei

                               Frequency     Emission Level(dBμV)         Limits(dBμV)        Margin(dBμV)
            Test Line
                                 MHz          QP             AV           QP        AV         QP      AV
                  Va             0.190         44.4        40.1          64.0        54.0     19.6     13.9
                  Va             0.515         35.1        28.7          56.0        46.0     20.9     17.3
                  Va             0.535         35.2        29.7          56.0        46.0     20.8     16.3
                  Va             0.935         37.0        28.8          56.0        46.0     19.0     17.2
                  Va             1.030         33.1        26.3          56.0        46.0     22.9     19.7
                  Va             1.395         33.3        27.5          56.0        46.0     22.7     18.5
                  Va             3.280         38.4        37.3          56.0        46.0     17.6      8.7
                  Va            14.600         39.0        36.1          60.0        50.0     21.0     13.9
                  Va            29.825         30.2        29.0          60.0        50.0     29.8     21.0
                  Vb             0.190         43.4        36.3          64.0        54.0     20.6     17.7
                  Vb             0.515         34.8        28.3          56.0        46.0     21.2     17.7
                  Vb             0.535         35.0        29.6          56.0        46.0     21.0     16.4
                  Vb             0.935         37.2        29.1          56.0        46.0     18.8     16.9
                  Vb             1.030         34.0        28.1          56.0        46.0     22.0     17.9
                  Vb             1.395         33.8        28.4          56.0        46.0     22.2     17.6
                  Vb             1.720         33.1        25.5          56.0        46.0     22.9     20.5
                  Vb             2.570         34.0        31.1          56.0        46.0     22.0     14.9
                  Vb             5.030         32.9        27.5          60.0        50.0     27.1     22.5

                  Vb            14.375         39.9        32.7          60.0        50.0     20.1     17.3

                  Vb            29.650         30.1        29.1          60.0        50.0     29.9     20.9

        The spectral diagrams in appendix I display the measurement of un-weighted peak values.




                                                                    Reviewer :



FCC ID: TUVMSEA                                             ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                         Page 9 of 25




          4. RADIATED EMISSION FOR FCC PART 15 SECTION 15.227(B)


                  4.1.Block Diagram of Test Setup
                       4.1.1.Block diagram of connection between the EUT and simulators

                                                      EUT

                                     (EUT: Wireless Optical Mouse)

                       4.1.2.Anechoic Chamber Test Setup Diagram


                                       ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                                     3 METERS




                                                                                  EUT

                   Cable
                                                                                          0.8 METER



                                       GROUND PLANE
                                     (EUT: Wireless Optical Mouse)


                  4.2.The Field Strength of Radiation Emission Measurement Limits
                       4.2.1. The field strength of any emissions which appear outside of this band shall not
                            exceed the general radiated emission limits in section 15.209
                                Radiation Emission Measurement Limits According to Section 15.209(a)
                                                                          Limit,
                      Frequency             Field Strength of        Field Strength of   The final measurement
                        (MHz)               Quasi-peak Value         Quasi-peak Value      in band 9-90kHz,
                                             (microvolts/m)             (dBμV/m)            110-490kHz and
                                                                                          above 1000MHz is
                           30 - 88                 100                      40              performed with
                                                                                           Average detector.
                        88 - 216                   150                     43.5               Except those


FCC ID: TUVMSEA                                                 ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                     Page 10 of 25


                                                                                           frequency bands
                       216 - 960                   200                   46
                                                                                          mention above, the
                                                                                        final measurement for
                                                                                          frequencies below
                       Above 960                   500                   54                  1000MHz is
                                                                                        performed with Quasi
                                                                                            Peak detector.




                  4.3.Configuration of EUT on Measurement
                     The following equipment are installed on Radiated Emission Measurement to meet the
                     commission requirements and operating regulations in a manner which tends to maximize
                     its emission characteristics in normal application.
                        4.3.1. Wireless Optical Mouse (EUT)
                             Model Number      :     DS-2121
                             Serial Number     :     N/A
                             Manufacturer      :     Eastern Times Technology Co., Ltd.


                  4.4.Operating Condition of EUT
                        4.4.1.Setup the EUT and simulator as shown as Section 3.1.

                        4.4.2.Turn on the power of all equipment.

                        4.4.3. Let the EUT work in TX modes(on) measure it.


                  4.5.Test Procedure
                     The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                     ground. The turntable can rotate 360 degrees to determine the position of the maximum
                     emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                     on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                     meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                     antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                     antenna are set on measurement. In order to find the maximum emission levels, all of the
                     interface cables must be manipulated according to FCC Part 15 Subpart C on radiated
                     emission measurement.

                     The bandwidth of test receiver (R&S ESI26) is set at 120KHz in 30-1000MHz.
                     The frequency range from 30MHz to 1000MHz is checked.

                      The final measurement in band 9-90kHz, 110-490kHz and above 1000MHz is performed
                      with Average detector. Except those frequency bands mention above, the final
                      measurement for frequencies below 1000MHz is performed with Quasi Peak detector.



FCC ID: TUVMSEA                                               ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                            Page 11 of 25




                  4.6.The Field Strength of Radiation Emission Measurement Results
                       PASS.
                       The frequency range 30MHz to 1000MHz is investigated.

         Date of Test:    December 16, 2005                        Temperature:      20oC
         EUT:             Wireless Optical Mouse                   Humidity:         50%
         Model No.:       DS-2121                                  Power Supply:     2.4V DC (“AAA”battery 2×)
         Test Mode:       TX                                       Test Engineer:    Andy


                        Frequency Reading(dBμV/m)  Factor Result(dBμV/m) Limits(dBμV/m) Margin(dBμV/m)
        Polarization                              Corr.( dB)
                          (MHz)                                  QP             QP            QP
                                         QP
         Horizontal      351.586           50.2            -17.7          32.5               46               13.5

         Horizontal      459.765           51.5            -16.0          35.5               46               10.5

         Horizontal      892.486           46.6            -12.0          34.6               46               11.4

          Vertical       81.136            48.8            -24.4          24.4              40.0              15.6

          Vertical       513.817           52.2            -15.0          37.2               46                8.8

          Vertical       552.942           51.5            -14.4          37.1               46                8.9


     The spectral diagrams in appendix 1 display the measurement of un-weighted peak values.
         The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
            Result = Reading + Corrected Factor
       Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain




FCC ID: TUVMSEA                                                    ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                            Page 12 of 25




         Date of Test:    December 16, 2005                        Temperature:       20oC
         EUT:             Wireless Optical Mouse                   Humidity:          50%
         Model No.:       DS-2121                                  Power Supply:      5V DC power by PC usb port
         Test Mode:       Charge                                   Test Engineer:     Andy


                       Frequency Reading(dBμV/m)  Factor Result(dBμV/m) Limits(dBμV/m) Margin(dBμV/m)
        Polarization                             Corr.( dB)
                         (MHz)                                  QP             QP            QP
                                        QP
         Horizontal      228.276           56.8            -22.2          34.6               46               11.4

         Horizontal      333.246           55.9            -18.3          37.6               46                8.4

         Horizontal      352.685           53.1            -17.7          35.4               46               10.6

         Horizontal      440.160           49.6            -16.1          33.5               46               12.5

          Vertical       131.082           51.6            -21.0          30.6              43.5              12.9

          Vertical       461.543           52.6            -15.9          36.7               46                9.3

          Vertical       480.982           47.8            -15.6          32.2               46               13.8

          Vertical       566.513           47.8            -14.4          33.4               46               12.6


     The spectral diagrams in appendix 1 display the measurement of un-weighted peak values.
         The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
            Result = Reading + Corrected Factor
       Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain




                                                                         Reviewer :




FCC ID: TUVMSEA                                                    ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                  Page 13 of 25




          5. FUNDAMENTAL RADIATED EMISSION FOR FCC PART 15

              SECTION 15.227(A)


                  5.1.Block Diagram of Test Setup
                        5.1.1.Block diagram of connection between the EUT and simulators

                                                  EUT

                                (EUT: Wireless Optical Mouse)

                        5.1.2.Anechoic Chamber Test Setup Diagram


                                   ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                  3 METERS




                                                                          EUT

                   Cable
                                                                                     0.8 METER



                                  GROUND PLANE

                                (EUT: Wireless Optical Mouse)


                  5.2.The Emission Limit For Section 15.227(a)
                     4.2.1 The field strength of any emission within this band shall not exceed
                     10,000microvolts/meter at 3 meters. The emission limit in this paragraph is based on
                     measurement instrumentation employing an average detector. The provisions in Section
                     15.35 for limiting peak emission apply.




FCC ID: TUVMSEA                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                     Page 14 of 25




                  5.3.EUT Configuration on Measurement
                     The following equipment are installed on the emission Measurement to meet the
                     commission requirements and operating regulations in a manner which tends to maximize
                     its emission characteristics in normal application.
                        5.3.1. Wireless Optical Mouse (EUT)
                             Model Number      :   DS-2121
                             Serial Number     :   N/A
                             Manufacturer      :   Eastern Times Technology Co., Ltd.


                  5.4.Operating Condition of EUT
                        5.4.1.Setup the EUT and simulator as shown as Section 4.1.

                        5.4.2.Turn on the power of all equipment.

                        5.4.3.Let the EUT work in TX mode (On) measure it.


                  5.5.Test Procedure
                     The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                     ground. The turntable can rotate 360 degrees to determine the position of the maximum
                     emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                     on an antenna tower. calibrated Loop antenna is used as receiving antenna. In order to
                     find the maximum emission levels, all of the interface cables must be manipulated
                     according to FCC Part 15 on radiated emission measurement.

                     The bandwidth of test receiver (R&S ESI26) is set at 9KHz in 9kHz-30MHz




FCC ID: TUVMSEA                                               ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                               Page 15 of 25




                  5.6.The Emission Measurement Result

                     PASS.

         Date of Test:   December 16, 2005              Temperature:      20oC
         EUT:            Wireless Optical Mouse         Humidity:         50%
         Model No.:      DS-2121                        Power Supply:     2.4V DC (“AAA”battery 2×)
         Test Mode:      TX                             Test Engineer:    Andy



       Fundamental Radiated Emissions

                          Test conditions                          Fundamental Frequency
                                                                         27.045MHz
                                  Unit                    (dBμV/m)/ (μV/m)        (dBμV/m)/(μV/m)
        Tnom(20°C)                                                AV                     PEAK
                                                               60.6/1,072              64.8/1,738
                      limit                                    80/10,000               100/100,000
        Note: Measurement was performed with modulated signal with average detector and peak

       The spectral diagrams in appendix 1.




                                                             Reviewer :




FCC ID: TUVMSEA                                         ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                       Page 16 of 25




          6. BAND EDGES


                  6.1.The Requirement
                     5.1.1. The wanted emission within the band 26.96-27.28MHz.


                  6.2.EUT Configuration on Measurement
                     The following equipment are installed on the emission Measurement to meet the
                     commission requirements and operating regulations in a manner which tends to maximize
                     its emission characteristics in normal application.
                        6.2.1.Wireless Optical Mouse (EUT)
                             Model Number        :   DS-2121
                             Serial Number       :   N/A
                             Manufacturer        :   Eastern Times Technology Co., Ltd.


                  6.3.Operating Condition of EUT
                        6.3.1.Setup the EUT and simulator as shown as Section 4.1.

                        6.3.2.Turn on the power of all equipment.

                        6.3.3.Let the EUT work in TX mode (On) measure it.




                  6.4.Test Procedure
                     The transmitter output was fed into the spectrum analyzer and photo was taken. The
                     vertical scale is set to 10dB per division; the horizontal scale is set to 32kHz per division.
                     Star frequency are 26.96MHz, stop frequency are 27.28MHz .
                     RBW are 3kHz, VBW are 3kHz, Sweep time are 50ms.




FCC ID: TUVMSEA                                                 ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                                                      Page 17 of 25




                  6.5.The Measurement Result

                     The EUT does meet the FCC requirement.


                        The spectral diagrams in appendix 1.




FCC ID: TUVMSEA                                                ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                                 Page 18 of 25




                  APPENDIX I
                  (Test Curves)




FCC ID: TUVMSEA           ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 19 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 20 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 21 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 22 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 23 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 24 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250


                                                         Page 25 of 25




FCC ID: TUVMSEA   ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20052250



Document Created: 2005-12-23 18:13:11
Document Modified: 2005-12-23 18:13:11

© 2024 FCC.report