Test Report

FCC ID: TUVDS2128TX

Test Report

Download: PDF
FCCID_739822

                                                                                                 Page 1 of 27




                                   FCC CERTIFICATION
                                        On Behalf of
                             Eastern Times Technology Co., Ltd.

                                 Wired &Wireless Mouse
                             Model No.: DS-2128(PCB 2128-X)

                                     FCC ID: TUVDS2128TX




            Prepared for      :   Eastern Times Technology Co., Ltd.
            Address           :   Building 5, Penghua Industry Park, Heping Rd.(W),
                                  Longhua, Shenzhen, Guangdong, P.R. China

            Prepared by       :   ACCURATE TECHNOLOGY CO. LTD
            Address           :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                  Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                  P.R. China

                                  Tel: (0755) 26503290
                                  Fax: (0755) 26503396




            Report Number     :   ATE20062552
            Date of Test      :   December 01, 2006
            Date of Report    :   December 05, 2006




FCC ID: TUVDS2128TX                                       ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                                                                           Page 2 of 27




                                                              TABLE OF CONTENTS

      Description                                                                                                                                                Page
      Test Report Certification
     1.      GENERAL INFORMATION .......................................................................................................... 4
          1.1.      Description of Device (EUT)....................................................................................................................4
          1.2.      Description of Test Facility ......................................................................................................................4
          1.3.      Measurement Uncertainty.........................................................................................................................4
     2.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 5
     3.      CONDUCTED EMISSION FOR FCC PART 15 SECTION 15.107(A) ...................................... 6
          3.1.      Block Diagram of Test Setup....................................................................................................................6
          3.2.      The Emission Limit For Section 15.107(a) ..............................................................................................6
          3.3.      EUT Configuration on Measurement .......................................................................................................7
          3.4.      Operating Condition of EUT ....................................................................................................................7
          3.5.      Test Procedure ..........................................................................................................................................7
          3.6.      Power Line Conducted Emission Measurement Results ..........................................................................8
     4.      RADIATED EMISSION FOR FCC PART 15 SECTION 15.109(A)........................................... 9
          4.1.      Block Diagram of Test Setup....................................................................................................................9
          4.2.      The Field Strength of Radiation Emission Measurement Limits..............................................................9
          4.3.      Configuration of EUT on Measurement .................................................................................................10
          4.4.      Operating Condition of EUT ..................................................................................................................10
          4.5.      Test Procedure ........................................................................................................................................10
          4.6.      The Field Strength of Radiation Emission Measurement Results ..........................................................11
     5.      RADIATED EMISSION FOR FCC PART 15 SECTION 15.227(B)......................................... 12
          5.1.      Block Diagram of Test Setup..................................................................................................................12
          5.2.      The Field Strength of Radiation Emission Measurement Limits............................................................12
          5.3.      Configuration of EUT on Measurement .................................................................................................13
          5.4.      Operating Condition of EUT ..................................................................................................................13
          5.5.      Test Procedure ........................................................................................................................................13
          5.6.      The Field Strength of Radiation Emission Measurement Results ..........................................................14
     6.      FUNDAMENTAL RADIATED EMISSION FOR FCC PART 15 SECTION 15.227(A) ........ 15
          6.1.      Block Diagram of Test Setup..................................................................................................................15
          6.2.      The Emission Limit For Section 15.227(a) ............................................................................................15
          6.3.      EUT Configuration on Measurement .....................................................................................................16
          6.4.      Operating Condition of EUT ..................................................................................................................16
          6.5.      Test Procedure ........................................................................................................................................16
          6.6.      The Emission Measurement Result ........................................................................................................17
     7.      BAND EDGES ................................................................................................................................. 18
          7.1.      The Requirement ....................................................................................................................................18
          7.2.      EUT Configuration on Measurement .....................................................................................................18
          7.3.      Operating Condition of EUT ..................................................................................................................18
          7.4.      Test Procedure ........................................................................................................................................18
          7.5.      The Measurement Result ........................................................................................................................19
           APPENDIX I ( TEST CURVES) (7pages)




FCC ID: TUVDS2128TX                                                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                    Page 3 of 27




                                      Test Report Certification

             Applicant          :   Eastern Times Technology Co., Ltd.
             Manufacturer       :   Eastern Times Technology Co., Ltd.
             EUT Description    :   Wired &Wireless Mouse
                                     (A) MODEL NO.: DS-2128(PCB 2128-X)
                                     (B) SERIAL NO.: N/A
                                     (C) POWER SUPPLY: 3.0V DC (“AAA” batteries 2×)

             Measurement Procedure Used:

             FCC Rules and Regulations Part 15 Subpart C Section 15.227, Section 15.107, Section 15.109:
             2006

             The device described above is tested by ACCURATE TECHNOLOGY CO. LTD to determine
             the maximum emission levels emanating from the device. The maximum emission levels are
             compared to the FCC Part 15 Subpart C Section 15.227 Section 15.107, Section 15.109limits.
             The measurement results are contained in this test report and ACCURATE TECHNOLOGY CO.
             LTD is assumed full responsibility for the accuracy and completeness of these measurements.
             Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with
             the FCC requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of ACCURATE TECHNOLOGY CO. LTD.

              Date of Test :                                    December 01, 2006


              Prepared by :


                                                                     (Engineer)


              Reviewer :

                                                                 (Quality Manager)

              Approved & Authorized Signer :

                                                                     (Manager)




FCC ID: TUVDS2128TX                                          ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                       Page 4 of 27




          1. GENERAL INFORMATION


                 1.1.Description of Device (EUT)
                      EUT                     :   Wired &Wireless Mouse

                      Model Number            :   DS-2128(PCB 2128-X)


                      Power Supply            :   3.0V DC (“AAA” batteries 2×) ,Can use USB cable to
                                                  charge and operation.

                      Applicant               :   Eastern Times Technology Co., Ltd.
                      Address                 :   Building 5, Penghua Industry Park, Heping Rd.(W),
                                                  Longhua, Shenzhen, Guangdong, P.R. China

                      Manufacturer            :   Eastern Times Technology Co., Ltd.
                      Address                 :   Building 5, Penghua Industry Park, Heping Rd.(W),
                                                  Longhua, Shenzhen, Guangdong, P.R. China

                      Date of sample received :   November 28, 2006

                      Date of Test            :   December 01, 2006


                 1.2.Description of Test Facility
                      EMC Lab                 :   Accredited by FCC
                                                  The Certificate Registration Number is 274801

                                                  Accredited by Industry Canada
                                                  The Certificate Registration Number is IC4174

                                                  Accredited by China National Accreditation Committee
                                                  for Laboratories
                                                  The Certificate Registration Number is L0579

                      Name of Firm            :   Shenzhen Academy of Metrology& Quality Inspection
                      Site Location           :   Bldg. Metrology& Quality Inspection, Longzhu Road,
                                                  Nanshan, Shenzhen, Guangdong, P.R. China


                 1.3.Measurement Uncertainty
                      Conducted emission expanded uncertainty     =    3.5dB, k=2

                      Radiated emission expanded uncertainty      =    4.5dB, k=2


FCC ID: TUVDS2128TX                                             ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                  Page 5 of 27




          2. MEASURING DEVICE AND TEST EQUIPMENT
               Table 1: List of Test and Measurement Equipment
                 Kind of equipment Manufacturer     Type              S/N               Calibrated until
                 EMI Test Receiver Rohde&Schwarz    ESCS30            100307            03.31.2007
                 EMI Test Receiver Rohde&Schwarz    ESI26             838786/013        01.28.2007
                 Loop Antenna      Schwarzbeck      FMZB1516          113               01.28.2007
                 Bilog Antenna     Schwarzbeck      VULB9163          9163-194          03.31.2007
                 Bilog Antenna     Chase            CBL6112B          2591              01.28.2007
                 Horn Antenna      Rohde&Schwarz    HF906             100013            01.28.2007
                 Spectrum Analyzer Anritsu          MS2651B           6200238856        03.31.2007
                 Pre-Amplifier     Agilent          8447D             2944A10619        03.31.2007
                 L.I.S.N.          Rohde&Schwarz    ESH3-Z5           100305            03.31.2007
                 L.I.S.N.          Rohde&Schwarz    ESH3-Z5           100310            03.31.2007




FCC ID: TUVDS2128TX                                        ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                       Page 6 of 27




          3. CONDUCTED EMISSION FOR FCC PART 15 SECTION

               15.107(A)


                3.1.Block Diagram of Test Setup
                        3.1.1.Block diagram of connection between the EUT and simulators

                                                     EUT             PC

                                      (EUT: Wired &Wireless Mouse)

                        3.1.2. Shielding Room Test Setup Diagram




                                     (EUT: Wired &Wireless Mouse)


                3.2.The Emission Limit For Section 15.107(a)
                      3.2.1 Radiation Emission Measurement Limits According to Section 15.107(a)
                        Frequency                         Conducted Limit (dBμV)

                         (MHz)                   Quasi-peak                     Average
                        0.15 – 0.5                66 to 56*                    56 to 46*
                         0.5 - 5                     56                            46
                          5 - 30                     60                            50
                      * Decreases with the logarithm of the frequency.



FCC ID: TUVDS2128TX                                             ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                       Page 7 of 27




                3.3.EUT Configuration on Measurement
                      The following equipment are installed on the emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to maximize
                      its emission characteristics in normal application.
                        3.3.1. Wired &Wireless Mouse (EUT)
                              Model Number      :   DS-2128(PCB 2128-X)
                              Serial Number     :   N/A
                              Manufacturer      :   Eastern Times Technology Co., Ltd.


                3.4.Operating Condition of EUT
                        3.4.1.Setup the EUT and simulator as shown as Section 3.1.

                        3.4.2.Turn on the power of all equipment.

                        3.4.3. Let the EUT work in wired modes (use USB cable connect to PC) measure it.




                3.5.Test Procedure
                      The EUT is put on the plane 0.8m high above the ground by insulating support and is
                      connected to the power mains through a line impedance stabilization network (L.I.S.N.).
                      This provides a 50ohm coupling impedance for the EUT system. Please refer the block
                      diagram of the test setup and photographs. Both sides of AC lines are checked to find out
                      the maximum conducted emission. In order to find the maximum emission levels, the
                      relative positions of equipment and all of the interface cables shall be changed according
                      to ANSI C63.4: 2003 on Conducted Emission Measurement.

                      The bandwidth of test receiver (R & S ESCS30) is set at 9kHz.

                      The frequency range from 150kHz to 30MHz is checked.

                      All the scanning waveforms are attached in Appendix I.




FCC ID: TUVDS2128TX                                             ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                    Page 8 of 27




                 3.6.Power Line Conducted Emission Measurement Results

                      PASS.

                      The frequency range from 150kHz to 30MHz is checked.


         Date of Test: December 01, 2006                    Temperature:   22oC
         EUT:          Wired &Wireless Mouse                Humidity:      51%
                                                                           DC 5V power by PC usb port
         Model No.:      DS-2128(PCB 2128-X)                Power Supply: PC power: AC120V/60Hz
         Test Mode:      Wired Connect to PC                Test Engineer: Andy

                              Frequency     Emission Level(dBμV)         Limits(dBμV)        Margin(dBμV)
             Test Line
                                MHz          QP             AV           QP        AV         QP      AV
                Va              0.190         45.4         36.9         64.0      54.0       18.6      17.1
                Va              0.515         36.2         28.0         56.0      46.0       19.8      18.0
                Va              0.935         37.9         28.4         56.0      46.0       18.1      17.6
                Va             13.770         36.6         27.1         60.0      50.0       23.4      22.9
                Va             26.200         35.5         30.4         60.0      50.0       24.5      19.6
                Vb              0.190         42.6         32.2         64.0      54.0       21.4      21.8
                Vb              0.515         36.3         28.3         56.0      46.0       19.7      17.7
                Vb              0.935         38.0         28.6         56.0      46.0       18.0      17.4
                Vb             13.850         44.3         28.3         60.0      50.0       15.7      21.7

                Vb             26.320         36.0         30.7         60.0      50.0       24.0      19.3



        The spectral diagrams in appendix I display the measurement of un-weighted peak values.




                                                                   Reviewer :




FCC ID: TUVDS2128TX                                          ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                          Page 9 of 27




          4. RADIATED EMISSION FOR FCC PART 15 SECTION 15.109(A)


                 4.1.Block Diagram of Test Setup
                          4.1.1.Block diagram of connection between the EUT and simulators

                                                         EUT            PC

                                        (EUT: Wired &Wireless Mouse)

                          4.1.2.Anechoic Chamber Test Setup Diagram


                                          ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                                        3 METERS




                                                                                    EUT

                      Cable
                                                                                           0.8 METER



                                          GROUND PLANE
                                        (EUT: Wired &Wireless Mouse)


                 4.2.The Field Strength of Radiation Emission Measurement Limits
                          4.2.1. Radiation Emission Measurement Limits According to Section 15.109(a)

                                                                          Limit,
                         Frequency             Field Strength of    Field Strength of      The final measurement
                          (MHz)                Quasi-peak Value     Quasi-peak Value         in band 9-90kHz,
                                                (microvolts/m)         (dBμV/m)               110-490kHz and
                                                                                            above 1000MHz is
                              30 - 88                100                     40                performed with
                                                                                             Average detector.
                          88 - 216                   150                     43.5               Except those
                                                                                              frequency bands
                          216 - 960                  200                     46             mention above, the


FCC ID: TUVDS2128TX                                                ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                       Page 10 of 27


                                                                                         final measurement for
                                                                                           frequencies below
                       Above 960                    500                    54
                                                                                              1000MHz is
                                                                                         performed with Quasi
                                                                                             Peak detector.




                 4.3.Configuration of EUT on Measurement
                      The following equipment are installed on Radiated Emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to maximize
                      its emission characteristics in normal application.
                        4.3.1. Wired &Wireless Mouse (EUT)
                             Model Number       :     DS-2128(PCB 2128-X)
                             Serial Number      :     N/A
                             Manufacturer       :     Eastern Times Technology Co., Ltd.


                 4.4.Operating Condition of EUT
                        4.4.1.Setup the EUT and simulator as shown as Section 3.1.

                        4.4.2.Turn on the power of all equipment.

                         4.4.3. Let the EUT work in Wired modes (use USB cable connect to PC) measure it.




                 4.5.Test Procedure
                      The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                      ground. The turntable can rotate 360 degrees to determine the position of the maximum
                      emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                      on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                      meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                      antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                      antenna are set on measurement. In order to find the maximum emission levels, all of the
                      interface cables must be manipulated according to FCC Part 15 Subpart C on radiated
                      emission measurement.

                      The bandwidth of test receiver (R&S ESCS30) is set at 120KHz in 30-1000MHz.
                      The frequency range from 30MHz to 1000MHz is checked.




FCC ID: TUVDS2128TX                                              ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                            Page 11 of 27




                 4.6.The Field Strength of Radiation Emission Measurement Results
                       PASS.
                       The frequency range 30MHz to 1000MHz is investigated.

         Date of Test: December 01, 2006                           Temperature:   22oC
         EUT:          Wired &Wireless Mouse                       Humidity:      51%
                                                                                  5V DC power by PC usb port
         Model No.:       DS-2128(PCB 2128-X)                      Power Supply: PC power: AC120V/60Hz
         Test Mode:       Wired connect to PC                      Test Engineer: Andy

                        Frequency Reading(dBμV/m)  Factor Result(dBμV/m) Limits(dBμV/m) Margin(dBμV/m)
        Polarization                              Corr.( dB)
                          (MHz)                                  QP             QP            QP
                                         QP
         Horizontal      223.030           24.2              9.7          33.9               46               12.1

         Horizontal      390.840           24.5             14.7          39.2               46                6.8

         Horizontal      449.040           24.3             16.0          40.3               46                5.7

          Vertical       219.150           24.3              8.8          33.1               46               12.9

          Vertical       440.310           21.5             16.2          37.7               46                8.3

          Vertical       440.310           17.3             20.6          37.9               46                8.1


      The spectral diagrams in appendix 1 display the measurement of un-weighted peak values.
         The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
             Result = Reading + Corrected Factor
       Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain




                                                                         Reviewer :




FCC ID: TUVDS2128TX                                                 ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                         Page 12 of 27




          5. RADIATED EMISSION FOR FCC PART 15 SECTION 15.227(B)


                 5.1.Block Diagram of Test Setup
                          5.1.1.Block diagram of connection between the EUT and simulators

                                                         EUT

                                        (EUT: Wired &Wireless Mouse)

                          5.1.2.Anechoic Chamber Test Setup Diagram


                                          ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                                        3 METERS




                                                                                  EUT

                      Cable
                                                                                           0.8 METER



                                          GROUND PLANE
                                        (EUT: Wired &Wireless Mouse)


                 5.2.The Field Strength of Radiation Emission Measurement Limits
                          5.2.1. The field strength of any emissions which appear outside of this band shall not
                               exceed the general radiated emission limits in section 15.209
                                   Radiation Emission Measurement Limits According to Section 15.209(a)
                                                                          Limit,
                         Frequency             Field Strength of    Field Strength of      The final measurement
                          (MHz)                Quasi-peak Value     Quasi-peak Value         in band 9-90kHz,
                                                (microvolts/m)         (dBμV/m)               110-490kHz and
                                                                                            above 1000MHz is
                              30 - 88                100                    40                performed with
                                                                                             Average detector.
                          88 - 216                   150                   43.5                 Except those


FCC ID: TUVDS2128TX                                                ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                       Page 13 of 27


                                                                                            frequency bands
                        216 - 960                   200                    46
                                                                                           mention above, the
                                                                                         final measurement for
                                                                                           frequencies below
                       Above 960                    500                    54                 1000MHz is
                                                                                         performed with Quasi
                                                                                             Peak detector.




                 5.3.Configuration of EUT on Measurement
                      The following equipment are installed on Radiated Emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to maximize
                      its emission characteristics in normal application.
                        5.3.1. Wired &Wireless Mouse (EUT)
                             Model Number       :     DS-2128(PCB 2128-X)
                             Serial Number      :     N/A
                             Manufacturer       :     Eastern Times Technology Co., Ltd.


                 5.4.Operating Condition of EUT
                        5.4.1.Setup the EUT and simulator as shown as Section 3.1.

                        5.4.2.Turn on the power of all equipment.

                        5.4.3. Let the EUT work in TX modes(on) measure it.


                 5.5.Test Procedure
                      The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                      ground. The turntable can rotate 360 degrees to determine the position of the maximum
                      emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                      on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                      meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                      antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                      antenna are set on measurement. In order to find the maximum emission levels, all of the
                      interface cables must be manipulated according to FCC Part 15 Subpart C on radiated
                      emission measurement.

                      The bandwidth of test receiver (R&S ESCS30) is set at 120KHz in 30-1000MHz.
                      The frequency range from 30MHz to 1000MHz is checked.
                       The final measurement in band 9-90kHz, 110-490kHz and above 1000MHz is performed
                       with Average detector. Except those frequency bands mention above, the final
                       measurement for frequencies below 1000MHz is performed with Quasi Peak detector.




FCC ID: TUVDS2128TX                                              ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                                Page 14 of 27




                 5.6.The Field Strength of Radiation Emission Measurement Results
                       PASS.
                       The frequency range 30MHz to 1000MHz is investigated.


         Date of Test:    December 01, 2006                          Temperature:        22oC
         EUT:             Wired &Wireless Mouse                      Humidity:           51%
         Model No.:       DS-2128(PCB 2128-X)                        Power Supply:       3.0V DC (“AAA”battery 2×)
         Test Mode:       TX                                         Test Engineer:      Andy


                        Frequency Reading(dBμV/m)  Factor Result(dBμV/m) Limits(dBμV/m) Margin(dBμV/m)
        Polarization                              Corr.( dB)
                          (MHz)                                  QP             QP            QP
                                         QP
         Horizontal         -                 -                 -              -                 -                  -

          Vertical          -                 -                 -              -                 -                  -




      The spectral diagrams in appendix 1 display the measurement of un-weighted peak values.
          1. Remark “- “ means that the emission level is too low to be measured.
          2. The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
             Result = Reading + Corrected Factor
       Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain




                                                                            Reviewer :




FCC ID: TUVDS2128TX                                                    ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                     Page 15 of 27




          6. FUNDAMENTAL RADIATED EMISSION FOR FCC PART 15

               SECTION 15.227(A)


                 6.1.Block Diagram of Test Setup
                          6.1.1.Block diagram of connection between the EUT and simulators

                                                    EUT

                                  (EUT: Wired &Wireless Mouse)

                          6.1.2.Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                    3 METERS




                                                                            EUT

                      Cable
                                                                                       0.8 METER



                                    GROUND PLANE

                                  (EUT: Wired &Wireless Mouse)


                 6.2.The Emission Limit For Section 15.227(a)
                       4.2.1 The field strength of any emission within this band shall not exceed
                       10,000microvolts/meter at 3 meters. The emission limit in this paragraph is based on
                       measurement instrumentation employing an average detector. The provisions in Section
                       15.35 for limiting peak emission apply.




FCC ID: TUVDS2128TX                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                     Page 16 of 27




                 6.3.EUT Configuration on Measurement
                      The following equipment are installed on the emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to maximize
                      its emission characteristics in normal application.
                        6.3.1. Wired &Wireless Mouse (EUT)
                             Model Number      :   DS-2128(PCB 2128-X)
                             Serial Number     :   N/A
                             Manufacturer      :   Eastern Times Technology Co., Ltd.


                 6.4.Operating Condition of EUT
                        6.4.1.Setup the EUT and simulator as shown as Section 4.1.

                        6.4.2.Turn on the power of all equipment.

                        6.4.3.Let the EUT work in TX mode (On) measure it.


                 6.5.Test Procedure
                      The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                      ground. The turntable can rotate 360 degrees to determine the position of the maximum
                      emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                      on an antenna tower. calibrated Loop antenna is used as receiving antenna. In order to
                      find the maximum emission levels, all of the interface cables must be manipulated
                      according to FCC Part 15 on radiated emission measurement.

                      The bandwidth of test receiver (R&S ESCS30) is set at 9KHz in 9kHz-30MHz




FCC ID: TUVDS2128TX                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                              Page 17 of 27




                 6.6.The Emission Measurement Result

                      PASS.

         Date of Test:   December 01, 2006             Temperature:      22oC
         EUT:            Wired &Wireless Mouse         Humidity:         51%
         Model No.:      DS-2128(PCB 2128-X)           Power Supply:     3.0V DC (“AAA”battery 2×)
         Test Mode:      TX                            Test Engineer:    Andy



       Fundamental Radiated Emissions

                          Test conditions                          Fundamental Frequency
                                                                         27.045MHz
                                  Unit                    (dBμV/m)/ (μV/m)        (dBμV/m)/(μV/m)
        Tnom(25°C)                                               PEAK                     AV
                                                               45.7/193                40.4/105
                      limit                                   100/100,000              80/10,000
        Note: Measurement was performed with modulated signal with average detector and peak
        detector.

       The spectral diagrams in appendix 1.




                                                            Reviewer :




FCC ID: TUVDS2128TX                                     ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                        Page 18 of 27




          7. BAND EDGES


                7.1.The Requirement
                      5.1.1. The wanted emission within the band 26.96-27.28MHz.


                7.2.EUT Configuration on Measurement
                      The following equipment are installed on the emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to maximize
                      its emission characteristics in normal application.
                         7.2.1.Wired &Wireless Mouse (EUT)
                              Model Number        :   DS-2128(PCB 2128-X)
                              Serial Number       :   N/A
                              Manufacturer        :   Eastern Times Technology Co., Ltd.


                7.3.Operating Condition of EUT
                         7.3.1.Setup the EUT and simulator as shown as Section 4.1.

                         7.3.2.Turn on the power of all equipment.

                         7.3.3.Let the EUT work in TX mode (On) measure it.




                7.4.Test Procedure
                      The transmitter output was fed into the spectrum analyzer and photo was taken. The
                      vertical scale is set to 10dB per division; the horizontal scale is set to 32kHz per division.
                      Star frequency are 26.96MHz, stop frequency are 27.28MHz .
                      RBW are 3kHz, VBW are 3kHz, Sweep time are 50ms.




FCC ID: TUVDS2128TX                                               ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                                                     Page 19 of 27




                7.5.The Measurement Result

                      The EUT does meet the FCC requirement.


                        The spectral diagrams in appendix 1.




FCC ID: TUVDS2128TX                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


                                                                     Page 20 of 27




                      APPENDIX I
                      (Test Curves)




FCC ID: TUVDS2128TX            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20062552


CONDUCTION EMISSION STANDARD FCC PART15B              oowss mss
eur           viitnimisns
lne           Exn tme
op on         comeer tore
oreabe        Antyie
Teriee»       Witatnoe
Eooo          mis chmsen
              wnosateap09 212229 sange w.cnuer

SeanSoteas 0 Rave
1+Eqi———it——teatvtatean     ——1
 t dle ty 19W Dnecer thtms Renmare
 k ul 9 on ns romenurout ore
 o van k m mewy mabroin ore
 io son ak m nowy meazroun cer
Protinmnnmmentx 9+ y               Tavaisarts Sn sup tane
         fise tw rs                     10w o sane


          0. we: ooo we se
sw        v. m: mone e aevare
w


m

w              —                                                   reersos


s         ~                                                        reeien
               s—

w


»


»


io


o
                                                                  ie


CONDUCTION EMISSION STANDARD FCC PART15B evaece ns
eur      Uiitnisies ie
lne      Enen oc
op con   comeerrore
oraie    Antyie
Terin:   W taitnoe
Eim      meas chuncss
         wnosztzapce 2tarx) Sange wcsuer

Seanarngs c na
boo—ragunce
  t 4 "Sup —1———ReemrSatrgn   ——1
                #BH Gercn ie menioare
 rek m w‘ ow mewy, nmnuroih ore
  mc w k m new. imnitoun ce
 fow on ase w ow. memiroin ore
Proiionme: xon+ 7                     Tavaisarts Sn sup tane
        featm 1s                           10w o sane


          0 mes nesmome usc
sw        v wl inmame macewy
w




w                                                                    recus


s                                                                    recism


w


»                                       Jln
                                 “‘M%
                                   \
»




    oig                      <                                 is   »
                                                                    im


     Levd (dBuin)




                                                                        1000


Trace:                                                     Ref Trace:

Condition:   FCC CLASS—B 3m ATC VULB9163(NEW) HORTZONTAL
eut          Wiredawireless Mouse
power         usp 5.09
memo          conwEcr To PC
manuf         Eastern Times
sample no.: ns4avs1i
             m/n: D8—2128 (PCB 2128—%)


    Levd (dBuin)




   * se                                                   206           1000
                                           Oy
Trace:                                                     Ref Trace:

Condition:    RCC CLASS—B 3m ATC VULBI163(NE®) VERTICAL
eut            Wiredawireless Mouse
power          usp 5.0v
memo           ConwECT To PC
manuf          Eastern Times
sample no.:    064081
              m/n: D8—2128 (BCB 2120—%)


  o Lovd ((dBuWim)




       30            24            41        él2         at6           1000


Trace:                                                    Ref Trace:

Condition: FCC CLASS—B 3m ATC VULB9163(NE®) HORTZONTAL
out         : Wiredawireless Mouse
power       : pe 3. 0v
memo        :fotk
manuf       : Easterm Times
sample no.: 064081
            :   m/n:Ds—2128(PCB 2120—%)


  go Lovd ((dBuWim)




                                                                      1000


Trace:                                                   Ref Trace:

Condition:   RCC CLASS—B Im ATC VULe9163(NEW) VERTICAL
eut            Wiredswireless Mouse
power          pe 3. 0V
memo           Tx
manuf          Easterm Times
sanple no.: 64081
               m/n: D8—2128 (PCB 2120—%)


                                              wazkes 1(2
                                                         as
                                                    cous
BR ;




       .               w)                                     sa
                       [\
       a>          \ | M
       —         LL\        c

       hunk en                  ht nfunNavh neAtnern se



Document Created: 2006-12-19 09:10:38
Document Modified: 2006-12-19 09:10:38

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC