customer reply 51109

FCC ID: TQ4YWGIT-R5678900

Cover Letter(s)

Download: PDF
FCCID_601291

 file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm

From: Jimmy Zhang [Jimmy.zhang@szhtw.com.cn]
Sent: Wednesday, November 09, 2005 1:13 PM
To: Tei
Subject: Re: TIMCO-TCB/Request for additional info - SHENZHEN YUANWANGGU INFORMATION
TECHNOLOGY CO., LTD. - FCC ID: TQ4YWGIT-R5678900

Importance: High
Hello Tei,

     Thanks very much for your mail and comments, the following are reply based on the questions.

     Response to Question #1:

                      On the revised test report, the Information about the external antenna has detailed on page 4
                      Section 1.1 (D) and on page 19 of the user manual

     Response to Question #2:

                          On the revised test report, the difference between XCRF-500 and XCRF-600 has giving a
description about
                      their feather. Both them has been modulated by meaningfull information and bear the same
bandwidth for
                      write to and read from.

     Response to Question #3:

                      The actual separation distance has been specified with 70 cm on page 13 of the user manual.

     Response to Question #4:

                      The same as response to question #2.


     Thanks very much!


     Best Regards!


                           Jimmy zhang


======== 2005-11-09 05:53:52 您在来信中写道: ========




 file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm (1 of 4)11/10/2005 5:49:04 AM


file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm



 TIMCO ENGINEERING INC.                                                                        TCB & FCB

 849 NW State Road 45                                                                              FCC Approvals

 Newberry, Florida 32669                                                                    Industry Canada Approvals

 http://www.timcoengr.com                                                                     Notified Body for Europe

 888.472.2424 F 352.472.2030 email: tei@timcoengr.com




 11/08/2005



 MR. JIMMY ZHANG

 SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD.

 86-755-26715686 86-755-26748089

 JIMMY.ZHANG@SZHTW.COM.CN; ZHOUZC@SZHTW.COM.CN



 SUBJECT: SHENZHEN YUANWANGGU INFORMATION TECHNOLOGY CO., LTD. -
 FCC ID: TQ4YWGIT-R5678900



 REFERENCE: JOB 2200CC5



 Dear MR. ZHANG:




file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm (2 of 4)11/10/2005 5:49:04 AM


file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm



 This application is on hold until these questions are resolved. Please answer all question(s)
 together and only respond to tei@timcoengr.com. Any other method will cause unnecessary delay. DO
 NOT HIT REPLY! Responses should also contain the Reference information, as shown at the top of this
 message. If acceptable response is not received within 2 week the job will be closed & there will be
 additional charges to reopen.




 Thank you for your reply and supporting documents. However, based upon our review of this
 application we have additional questions:



               1. Question 3 from previous letter: Please specify the model number, brand, and gain of
               tested and approved antenna only. No answer was provided for this request.




               2. Question 6 from previous letter: I understand that the model XCRF-600 transmits without
               modulation to the tag. If so, the XCRF-600 does not satisfy the requirement of a 2.1. Please
               explain the purpose of the modulated signal after the tag is activated. The FCC requires that the
               system does NOT employs useless modulation (information not written to, or read from the
               passive tag) just to comply with paragraph (a)(1) transmit/receive bandwidth requirement, does
               not meet the intent of Section 2.1. The reader must be able to write to, and read information
               from, the passive tag. Please explain and confirm the above.




               3. Question 9 from previous letter: RF exposure exhibit per part 15.247(b)(5): Please provide
               the actual separation distance required to satisfy compliance with the FCC RF exposure
               requirements. The calculated distance must be included with the Professional Installer’s
               installation instructions as such: “WARNING: FCC RF Exposure Requirements: The
               antenna(s) used for this transmitter must be installed to provide a separation distance of at least
               xxx cm from all persons and must not be co-located or operating in conjunction with any other
               antenna or transmitter.”




 For your info - Please note that the FCC requires that we list the required separation distance
 on the Grant of Equipment Authorization.

file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm (3 of 4)11/10/2005 5:49:04 AM


file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm




               4. Question 13 from previous letter Part 2.1 Frequency hopping definition: Please reply
               according to Question 6. from previous letter and item. 2 above.




 Sincerely,



 Bruno Clavier




======================

                       致
礼!


                                          Jimmy Zhang
                                          Jimmy.zhang@szhtw.com.cn
                                             2005-11-10




file:///U|/S/SHENZ_TQ4/2200CC5/cust%20reply%20-%2051109.htm (4 of 4)11/10/2005 5:49:04 AM



Document Created: 2005-11-10 10:50:51