FCC Part 15.225 Test Report

FCC ID: TMEWR5000X012

Test Report

Download: PDF
FCCID_3728912

                                                   Test Report
                                           Prepared for: Blackboard, Inc.

                                                   Model: WR5000

                     Description: Security Access systems and as an attendance wall reader

                                                 Serial Number: N/A

                                             FCC ID: TMEWR5000X012
                                              IC: 8327A-WR5000X012

                                                          To

                                                   FCC Part 15.225

                                           Date of Issue: January 19, 2018


On the behalf of the applicant:             Blackboard, Inc.
                                            22601 N 19th Ave
                                            Suite 130
                                            Phoenix, AZ 85027

Attention of:                               Tim Mattson, Hardware Engineer
                                            Ph: (623)476-1141
                                            E-Mail: Tim.Mattson@blackboard.com



                                                   Prepared by
                                             Compliance Testing, LLC
                                                1724 S. Nevada Way
                                                  Mesa, AZ 85204
                                     (480) 926-3100 phone / (480) 926-3598 fax
                                            www.compliancetesting.com
                                               Project No: p1770014




                                                                        Alex Macon
                                                                        Project Test Engineer



       This report may not be reproduced, except in full, without written permission from Compliance Testing.
                              All results contained herein relate only to the sample tested

                                                                                  p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                       Page 1 of 14


                              Test Report Revision History

Revision   Date                  Revised By             Reason for Revision

  1.0      October 9, 2017       Alex Macon             Original Document
                                                        Updated table on page 8
                                                        Added measured frequency to page 9
  2.0      January 18, 2018      Alex Macon
                                                        Updated C63.10 version on page 6
                                                        Clarified test procedure on page 10
                                                        Included additional statement in the
  3.0      January 19, 2018      Alex Macon
                                                        field strength test procedure




                                                                 p1770014_FCC_Part 15.225_Rev 3.0
                                                                                      Page 2 of 14


                                                              Table of Contents

Description                                                                                                                                       Page

 Standard Test Conditions Engineering Practices ............................................................................... 6
 Test Results Summary ........................................................................................................................ 7
 Field Strength ...................................................................................................................................... 8
 Frequency Stability .............................................................................................................................. 9
 Radiated Emissions........................................................................................................................... 10
 Powerline Conducted Emissions ....................................................................................................... 11
 99% Occupied Bandwidth ................................................................................................................. 13
 Test Equipment Utilized .................................................................................................................... 14




                                                                                                               p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                                                    Page 3 of 14


                                                         ILAC / A2LA

Compliance Testing, LLC, has been accredited in accordance with the recognized International Standard ISO/IEC
17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory
quality management system (refer to the joint ISO-ILAC-IAF Communiqué dated January 2009).

The tests results contained within this test report all fall within our scope of accreditation, unless noted in the table below.

Please refer to http://www.compliancetesting.com/labscope.html for current scope of accreditation.

Testing Certificate Number: 2152.01




FCC Site Reg. #349717

IC Site Reg. #2044A-2


       Non-accredited tests contained in this report:

       N/A




                                                                                         p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                              Page 4 of 14


                                The applicant has been cautioned as to the following:

15.21 Information to User

The user’s manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

15.27(a) Special Accessories

Equipment marketed to a consumer must be capable of complying with the necessary regulations in the configuration in
which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are
required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment
must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging
the special accessories with the unintentional or intentional radiator the responsible part may employ other methods of
ensuring that the special accessories are provided to the consumer, without an additional charge.

Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization
or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in § 2.909 of
this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such
devices shall include appropriate instructions on the first page of text concerned with the installation of the device that
these special accessories must be used with the device. It is the responsibility of the user to use the needed special
accessories supplied with the equipment.




                                                                                     p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                          Page 5 of 14


Standard Test Conditions Engineering Practices

Except as noted herein, the following conditions and procedures were observed during the testing:

In accordance with ANSI C63.10-2013 and unless otherwise indicated in the specific measurement results, the ambient
temperature of the actual EUT was maintained within the range of 10° to 40°C (50° to 104°F), unless the particular
equipment requirements specified testing over a different temperature range. Also, unless otherwise indicated, the
humidity levels were in the range of 10% to 90% relative humidity.

Measurement results, unless otherwise noted, are worst-case measurements.

                                                Environmental Conditions
                            Temperature               Humidity                  Pressure
                               (°C)                     (%)                      (mbar)
                             23.2 – 24.8               31 - 36                  966 - 969
EUT Description
Model: WR5000
Description: Security Access systems and as an attendance wall reader
Firmware: N/A
Software: N/A
Serial Number: N/A
Additional Information:
The device incorporated and NFC transmitter at 13.56MHz and a pre-certified 2.4GHz module.

EUT Operation during Tests
The device was placed in continuous transmit tone during all testing.




         Accessories: None

         Cables: None

         Modifications: None




                                                                                     p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                          Page 6 of 14


Test Results Summary

                                                          Pass,
  Specification                Test Name                                            Comments
                                                         Fail, N/A
15.225(a)         Fundamental Field Strength               Pass

15.225(b)(c)(d)   Out of Band Spurious Emissions           Pass

15.225(e)         Frequency Stability                      Pass

12.209            Radiated Emissions                       Pass

12.207            Conducted Powerline Emissions            Pass

RSS-210           99% Occupied Bandwidth                   Pass




15.203: Antenna Requirement:

                                        X      The antenna is permanently attached to the EUT

                                               The antenna uses a unique coupling

                                               The EUT must be professionally installed

                                               The antenna requirement does not apply




                                                                               p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                    Page 7 of 14


Field Strength
Engineer: Alex Macon
Test Date: 9/12/17

                                                    Test Procedure

The EUT was tested in an anechoic chamber at a distance of 1 meter from the receiving loop antenna and characterized
to the 30 meter limit(40log (1m/30m) A spectrum analyzer was used to verify that the EUT met the requirements for
Fundamental Field Strength. The antenna correction and distance correction factors were summed with the quasi-peak
measurement to ensure accurate readings were obtained. The following table indicates the highest emission in each of
the indicated bands. Measurements were made with an amplified loop antenna and converted to field strength.

                                                       Test Setup

                                                                                Spectrum
                               EUT                      Antenna
                                                                                Analyzer




                                                     Field Strength

  Frequency         Measured         Monitored                                    Corrected
                                                  Distance CF     Antenna CF                          Limit
     Band           Frequency          Level                                     Measurement                      Result
                                                      (dB)           (dB)                           (dBuV/m)
    (MHz)             (MHz)          (dBuV/m)                                     (dBuV/m)
13.110_13.410         13.347           62.95          59.1            17.8           21.65            40.51        Pass

13.410_13.553         13.553           73.94          59.1            17.8           32.64            50.47        Pass

13.553_13.567        13.5593           78.13          59.1            17.8           36.83            84.00        Pass

13.567_13.710         13.567           70.76          59.1            17.8           29.46            50.47        Pass

13.710_14.010         13.773           58.71          59.1            17.8           17.41            40.51        Pass

Note: Cable correction factors are not included in this measurement as the low loss of the high quality TWINAX cable at
low frequencies in practically non-existent.




                                                                                   p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                        Page 8 of 14


Frequency Stability
Engineer: Alex Macon
Test Date: 9/20/17

                                                                    Test Procedure

The EUT was placed in an environmental test chamber and a frequency counter was utilized to verify that the frequency
stability met the requirement for frequency stability across the temperature range from -20°C to +50°C. A variable DC
power supply was used to vary the voltage from 85% to 115% of the rated voltage.
Transmitter Frequency: 13.559291667 MHz
Lower Limit: 13.5579357 MHz
Upper Limit: 13.5606476 MHz
                                                          Test Setup

                                            DC Power                                                 Frequency
                                                                         EUT
                                             Supply                                                   Counter



                                                             Frequency Stability vs. Voltage
                            13.561
                            13.561                                                                                Upper Limit

                            13.560
          Frequency (MHz)




                            13.560                                                                                Measured
                            13.559                                                                                Frequency

                            13.559
                                                                                                                  Lower Limit
                            13.558
                            13.558
                                 10.00     10.50    11.00   11.50   12.00 12.50      13.00   13.50    14.00
                                                                    Voltage



                                                  Frequency Stability vs. Temperature
                            13.561
                            13.561                                                                               Upper Limit

                            13.560
          Frequency (MHz)




                            13.560                                                                               Measured
                            13.559                                                                               Frequency

                            13.559
                                                                                                                 Lower Limit
                            13.558
                            13.558
                                     -30    -20      -10     0     10      20     30          40        50
                                                            Temperature (Centigrade)

*Note: The hardware is limited by the LCD screens minimum temperature rating of 0˚C




                                                                                                     p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                                          Page 9 of 14


Radiated Emissions
Engineer: Alex Macon
Test Date: 9/20/17

                                                  Test Procedure

The EUT was tested in a semi-anechoic chamber at a distance of 3 meters from the receiving antenna. A spectrum
analyzer was used to verify that the UUT met the requirements for Radiated Emissions. The spectrum was examined from
9kHz to 1 GHz those emissions closest to their respective limits have been documented below.

                                                    Test Setup

                                                                              Spectrum
                               EUT                     Antenna
                                                                              Analyzer



                                               Radiated Emissions


 Emission          Measured                                        Antenna      Antenna       Turntable
                                     Limit          Margin
 Frequency           Value                                          Height      Polarity       Position    Detector
                                   (dBuV/m)          (dB)
   (MHz)           (dBuV/m)                                          (cm)        (dB)         (degrees)
   124.146          29.788            43.5          -13.712          400            V            241          PK

  136.9357          31.247            43.5          -12.253          175            V            261          PK

  593.8103          36.524             46            -9.476          325            V            292          PK

  757.9441          36.528             46            -9.472          100            V            122          PK

  996.3289          36.541            53.9          -17.359          400            V            127          PK

  999.8816          38.704            53.9          -15.196          250            V            263          PK




                                                                                p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                    Page 10 of 14


Powerline Conducted Emissions
Engineer: Alex Macon
Test Date: 9/20/17

                                                  Test Procedure
The EUT power cable connected to a LISN and the monitored output of the LISN was connected directly to a spectrum
analyzer. The conducted emissions from 150 kHz to 30 MHz were monitored and compared to the specification limits. The
average measurements were the worst case and are recorded in the tables below.

                                                         Test Setup

                       EUT
                                                             LISN                     Spectrum Analyzer
                    Power Cable


                                                      Line 1 Peak Plot




                                                      Line 2 Peak Plot




All other results were greater than 20 dB below the limit.

                                                                                p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                    Page 11 of 14


                                  Line 1 Neutral Avg Detector
             Measured   LISN Correction
                                          Cable Loss Attenuator   Final Data    Limit    Avg Margin
Frequency      Value        Factor
                                             (dB)         (dB)     (dBuV)      (dBuV)       (dB)
              (dBuV)         (dB)
439.4 KHz      16.51          0.1            0.03         10.1      26.74      47.731      -21.00
445.14 KHz    17.46          0.1            0.03        10.1        27.69      47.567      -19.88
457.45 KHz    12.97          0.1            0.03        10.1        23.20      47.216      -24.01
459.05 KHz    11.89          0.1            0.03        10.1        22.12      47.17       -25.05
490.33 KHz    13.09          0.1            0.03        10.1        23.32      46.276      -22.96
13.562 MHz    36.66           0             0.18        10.2        47.04       50         -2.96

                                   Line2 Phase Avg Detector
             Measured   LISN Correction
                                          Cable Loss Attenuator   Final Data    Limit    Avg Margin
Frequency      Value        Factor
                                             (dB)        (dB)       (dBuV)     (dBuV)       (dB)
              (dBuV)         (dB)
476.09 KHz     15.62          0.1            0.03        10.1       25.85      46.683      -20.83
478.24 KHz    15.34          0.1            0.03        10.1        25.57      46.622      -21.06
491.23 KHz    14.12          0.1            0.03        10.1        24.35      46.251      -21.90
494.93 KHz    13.62          0.1            0.03        10.1        23.85      46.145      -22.30
495.1 KHz     13.81          0.1            0.03        10.1        24.04      46.14       -22.10
13.56 MHz     37.93           0             0.18        10.2        48.31        50        -1.69

                                   Line 1 Neutral QP Detector
             Measured   LISN Correction
                                          Cable Loss Attenuator   Final Data     Limit    QP Margin
Frequency      Value        Factor
                                             (dB)          (dB)    (dBuV)       (dBuV)      (dB)
              (dBuV)         (dB)
439.4 KHz      32.84          0.1            0.03          10.1      43.07      57.731      -14.66
445.14 KHz    32.85          0.1            0.03        10.1         43.08      57.567      -14.49
457.45 KHz    30.46          0.1            0.03        10.1         40.69      57.216      -16.53
459.05 KHz     29.8          0.1            0.03        10.1         40.03       57.17      -17.14
490.33 KHz    29.21          0.1            0.03        10.1         39.44      56.276      -16.84
13.562 MHz    47.89           0             0.18        10.2         58.27        60        -1.73

                                  Line 2 Phase 2 QP Detector
             Measured   LISN Correction
                                          Cable Loss Attenuator   Final Data     Limit    QP Margin
Frequency      Value        Factor
                                             (dB)        (dB)      (dBuV)       (dBuV)      (dB)
              (dBuV)         (dB)
476.09 KHz     28.66          0.1            0.03        10.1        38.89      56.683      -17.79
478.24 KHz    28.80          0.1            0.03        10.1         39.03      56.622      -17.59
491.23 KHz    28.03          0.1            0.03        10.1         38.26      56.251      -17.99
494.93 KHz    27.78          0.1            0.03        10.1         38.01      56.145      -18.14
495.1 KHz     28.29          0.1            0.03        10.1         38.52       56.14      -17.62
13.56 MHz     47.86           0             0.18        10.2         58.24        60        -1.76




                                                                  p1770014_FCC_Part 15.225_Rev 3.0
                                                                                      Page 12 of 14


99% Occupied Bandwidth
Engineer: Alex Macon
Test Date: 9/12/17

                                                  Test Procedure

The EUT was tested on an anechoic chamber at a distance of 1 meter from the receiving loop antenna. A spectrum
analyzer was used to measure the 99% occupied bandwidth.

                                                    Test Setup


                                                                                Spectrum
                             EUT                       Antenna
                                                                                Analyzer


                                             99% Bandwidth Summary

                              Frequency
                                                 Recorded Measurement            Result
                                (MHz)
                                13.56                     847 Hz                  Pass




                                                                                p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                    Page 13 of 14


 Test Equipment Utilized


       Description          Manufacturer               Model #              CT Asset #      Last Cal Date     Cal Due Date

Temperature Chamber        Tenney            Tenney Jr                      i00027         Verified on: 9/20/17

EMI Receiver               HP                8546A                          i00033         3/28/17           3/28/18

Transient Limiter          Com-Power         LIT-153                        i00123         Verified on: 9/20/17

Humidity / Temp Meter      Newport           IBTHX-W-5                      i00282         6/9/17            6/9/18

Active Loop Antenna        EMCO              6507                           i00326         9/25/17           9/25/19

Spectrum Analyzer          Agilent           E4407B                         i00331         10/19/16          10/19/17

Data Logger                Fluke             Hydra Data Bucket              i00343         5/25/17           5/25/18

Bi-Log Antenna             Schaffner         CBL 6111D                      i00349         8/3/16            8/3/18

AC Power Source            Behlman           BL 6000                        i00362         Verified on: 9/20/17

EMI Analyzer               Agilent           E7405A                         i00379         2/22/17           2/22/18
3 Meter Semi-Anechoic                        3 Meter Semi-Anechoic
                           Panashield                                       i00428         8/15/16           8/15/19
Chamber                                      Chamber
LISN                       COM-Power         LI-125A                        i00447         9/11/17           9/11/19

LISN                       COM-Power         LI-125A                        i00449         9/11/17           9/11/19

 In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the described
 equipment. Prior to testing these components were tested to verify proper operation.




 END OF TEST REPORT




                                                                                     p1770014_FCC_Part 15.225_Rev 3.0
                                                                                                         Page 14 of 14



Document Created: 2018-01-19 16:24:06
Document Modified: 2018-01-19 16:24:06

© 2024 FCC.report