Test Report 15B

FCC ID: TMEVR4100X003

Test Report

Download: PDF
FCCID_1130663

Date:                             April 16, 2009

Applicant:                        Blackboard, Inc.
                                  22601 North 19th Ave, Suite 200
                                  Phoenix, AZ 85027

Attention of:                     Tom Kuestersteffen
                                  623-476-1263
                                  email: tkuestersteffen@blackboard.com
                                  and/or Tim Mattson
                                  623-476-1400

Equipment:                        VR4000

FCC Rules:                        Part 15, Subpart B. Class B Limits.

Gentlemen:

Enclosed please find your copy of the Test Data Report for the referenced equipment.

Please keep the original on record for submission to the FCC, but only if and when they request it.

In the event the FCC ever requests this submission, please complete all the documentation requirements, (as per
the LIST OF EXHIBITS) before sending.

Should you have any questions, please do not hesitate to call.




                                                                  Sincerely yours,




                                                                  Hoosamuddin S. Bandukwala, Lab Director


Flom Test Lab
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                        p0910004, d0940010 Rev 1.0


                                       (Unintentional Radiator)

                                                   of

                                            Model: VR4000


                                                   to

                                Federal Communications Commission

                           Rule Part 15, Subpart B - Unintentional Radiators

                                            Class B Limits

                                     Date of Report: April 16, 2009

At the Request of:             Blackboard, Inc.
                               22601 North 19th Ave, Suite 200
                               Phoenix, AZ 85027

Attention of:                  Tom Kuestersteffen
                               623-476-1263
                               email: tkuestersteffen@blackboard.com
                               and/or Tim Mattson
                               623-476-1400




Reviewed By:                                                  Hoosamuddin S. Bandukwala, Lab Director




Flom Test Lab
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                  p0910004, d0940010 Rev 1.0


                                   Test Report Revision History
Revision          Date                           Revised By           Reason for revision
1.0               April 16, 2009                 J Erhard             Original Document




Flom Test Lab
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                          p0910004, d0940010 Rev 1.0


                            The applicant has been cautioned as to the following:

15.21            Information to User.

The users manual or instruction manual for an intentional radiator shall caution the user that changes or
modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.

15.27(a)         Special Accessories.

Equipment marketed to a consumer must be capable of complying with the necessary regulations in the
configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or
special connectors are required to enable an unintentional or intentional radiator to comply with the emission
limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories.
However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the
responsible party may employ other methods of ensuring that the special accessories are provided to the
consumer, without additional charge.

Information detailing any alternative method used to supply the special accessories for a grant of equipment
authorization or retained in the verification records, as appropriate. The party responsible for the equipment, as
detailed in § 2.909 of this chapter, shall ensure that these special accessories are provided with the equipment.
The instruction manual for such devices shall include appropriate instructions on the first page of text concerned
with the installation of the device that these special accessories must be used with the device. It is the
responsibility of the user to use the needed special accessories supplied with the equipment.




Flom Test Lab
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                            p0910004, d0940010 Rev 1.0


                             Testimonial And Statement Of Certification


This is to certify that:


        1.       That the application was prepared either by, or under the direct supervision of, the undersigned.

        2.       That the technical data supplied with the application was taken under my direction and
                 supervision.

        3.       That the data was obtained on representative units, randomly selected.

        4.       That, to the best of my knowledge and belief, the facts set forth in the application and
                 accompanying technical data are true and correct.




Certifying Engineer:                                                Hoosamuddin S. Bandukwala, Lab Director




Flom Test Lab
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                          p0910004, d0940010 Rev 1.0


                                           Table Of Contents
Rule                  Description                                                                Page

                      Test Report                                                                   1

.                     Standard Test Conditions and Engineering Practices                            2

                      Test Results Summary                                                          3

15.109                Radiated Emissions                                                            4

15.107                Powerline Conducted Emissions                                                 5

                      Test Setup Photos                                                             6

                      Test Equipment Utilized                                                       8




Flom Test Lab
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                   p0910004, d0940010 Rev 1.0


Required information per ISO 17025-2005, paragraph 5.10.2:
a)                                            Test Report

b) Laboratory:                 Flom Test Lab, Inc.
 (FCC: 31040/SIT)              3356 N. San Marcos Place, Suite 107
 (Canada: IC 2044A-1)          Chandler, AZ 85225

c) Report Number:              d0940010

d) Client:                     Blackboard, Inc.

e) Identification:             VR4000

  Description:                 Wireless Vending Machine Coin Unit

f) EUT Condition:              Not required unless specified in individual tests.

g) Report Date:                April 16, 2009

h, j, k):                      As indicated in individual tests.

i) Sampling method:            No sampling procedure used.

l) Uncertainty:                In accordance with FTL internal quality manual.

m) Supervised by:




                               Hoosamuddin S. Bandukwala, Lab Director

n) Results:                    The results presented in this report relate only to the item tested.

o) Reproduction:               This report must not be reproduced, except in full, without written permission
                               from this laboratory.




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                    Page 1 of 8
(866) 311-3268 phone, (480) 926-3598 fax                                        p0910004, d0940010 Rev 1.0


Sub-part
2.1033(b):                                 Test And Measurement Data

All tests and measurement data shown were performed in accordance with FCC Rules and Regulations, Volume
II; Part 2 and the following individual Parts: 15.107, 15.109; Unintentional Radiators


                            Standard Test Conditions and Engineering Practices

Except as noted herein, the following conditions and procedures were observed during the testing:

In accordance with ANSI C63.4-2004, and unless otherwise indicated in the specific measurement results, the
ambient temperature of the actual EUT was maintained within the range of 10° to 40°C (50° to 104 °F) unless the
particular equipment requirements specify testing over a different temperature range. Also, unless otherwise
indicated, the humidity levels were in the range of 10% to 90% relative humidity.

Prior to testing, the EUT was tuned up in accordance with the manufacturer's alignment procedures. All external
gain controls were maintained at the position of maximum and/or optimum gain throughout the testing.

Measurement results, unless otherwise noted, are worst-case measurements.


                                                     A2LA

“A2LA has accredited Flom Test Labs, Inc. Chandler, AZ for technical competence in the field of Electrical
testing. The accreditation covers the specific tests and types of tests listed on the agreed scope of
accreditation. This laboratory meets the requirements of ISO 17025:2005 ‘General Requirements for the
Competence of Testing and Calibration Laboratories’ and any additional program requirements in the
identified field of testing.”

Please refer to www.a2la.org for current scope of accreditation.

Certificate number: 2152.01




FCC OATS Reg. #933597

IC O.A.T.S. Number: 2044A-1




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                    Page 2 of 8
(866) 311-3268 phone, (480) 926-3598 fax                                        p0910004, d0940010 Rev 1.0


                                           Test Results Summary

   Specification               Test Name                  Pass, Fail, N/A          Comments
      15.109              Radiated Emissions                  Pass
      15.107         Powerline Conducted Emissions            Pass




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                Page 3 of 8
(866) 311-3268 phone, (480) 926-3598 fax                                    p0910004, d0940010 Rev 1.0


Name of Test:                      Radiated Emissions
Specification:                     15.109                                  Engineer: J Erhard
Test Equipment Utilized            i00049, i00088, i00089                  Test Date: 4/16/2009

                                                 Test Procedure

The UUT was tested in an Open Area Test Site (OATS) set 3m from the receiving antenna. A spectrum analyzer
was used to verify that the UUT met the requirements for Radiated Emissions. The UUT was tested by rotating it
360° with the antennas in both the vertical and horizontal orientation and raised from 1 to 4 meters to ensure the
TX signal levels were maximized. All emissions from 30 MHz to 1 GHz were examined.

                                                   Test Setup


                        UUT                    Antenna                  Spectrum
                                                                        Analyzer

Settings
RBW = 100 KHz
VBW = 100KHz
Detector – Quasi Peak
Sample Calculations
Corrected Value = Measured Value + Correction factor
Correction factor = ACF + Cable loss


                                   Radiated Emissions with Wi-Fi operational

        Emission Freq    Measured Value       Correction Factor    Corrected Value      Limit      Margin
           (MHz)           (dBuV/m)                 (dB)              (dBuV/m)        (dBuV/m)       dB
           50.465             9.5                    9.8                19.3            40.0       -20.7
          117.990            15.8                   13.2                29.0            43.0       -14.0
          221.699            22.2                   12.2                34.4            46.0       -11.6
          224.449             8.6                   12.5                21.1            46.0       -24.9
          346.424            20.9                   17.4                38.3            46.0        -7.7
          406.235            10.8                   19.2                30.0            46.0       -16.0

                              Radiated Emissions with cabled Ethernet operational

        Emission Freq    Measured Value       Correction Factor    Corrected Value      Limit      Margin
           (MHz)           (dBuV/m)                 (dB)              (dBuV/m)        (dBuV/m)       dB
           47.474            10.2                   11.3                21.5            40.0       -18.5
          116.324            15.6                   13.1                28.7            43.0       -14.3
          221.699            28.6                   12.2                40.9            46.0        -5.1
          223.279            22.0                   12.4                34.4            46.0       -11.7
          232.404            15.7                   13.1                28.8            46.0       -17.2
          352.624            25.0                   17.6                42.7            46.0        -3.3




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                     Page 4 of 8
(866) 311-3268 phone, (480) 926-3598 fax                                         p0910004, d0940010 Rev 1.0


Name of Test:                    Powerline Conducted Emissions
Specification:                   15.107                                   Engineer: J Erhard
Test Equipment Utilized          i00033, i00270                           Test Date: 4/16/2009

                                                Test Procedure

The UUT power cable connected to a LISN and the monitored output of the LISN was connected directly to a
spectrum analyzer. The conducted emissions from 150 kHz to 30 MHz were monitored and compared to the
specification limits.

                                                    Test Setup

                                                                     Spectrum
                                                                     Analyzer
                                    LISN

                                                                       UUT
                                                                    Power Cable

                                        Line 1 Quasi-Peak Test Results

            Emission      Monitored        LISN       Attenuation    Corrected      Limit     Margin
           Frequency        Level          Factor         (dB)         Level      (dBuV/m)     (dB)
                          (dBuV/m)          (dB)                     (dBuV/m)
          208.93 KHz        43.93            0.2             10        54.16        64.32     -10.16
          200.84 KHz        44.1             0.2             10        54.33        64.55     -10.22
          200.44 KHz        43.88            0.2             10        54.1         64.56     -10.46
          184.11 KHz        43.83            0.2             10        54.03        65.03     -10.99
          183.14 KHz        43.76            0.2             10        53.96        65.05     -11.09
          162.08 KHz        44.31            0.2             10        54.54        65.65     -11.11

                                        Line 2 Quasi-Peak Test Results

            Emission      Monitored        LISN       Attenuation    Corrected      Limit     Limit
           Frequency        Level          Factor         (dB)         Level      (dBuV/m)    (dB)
                          (dBuV/m)          (dB)                     (dBuV/m)
          162.32 KHz        44.02            0.2             10        54.25        65.65     -11.39
          162.02 KHz         44              0.2             10        54.23        65.66     -11.42
          158.94 KHz        44.21           0.21             10        54.46        65.74     -11.29
          156.58 KHz        44.21           0.23             10        54.48        65.81     -11.33
          154.08 KHz        43.95           0.26             10        54.24        65.88     -11.64
          151.81 KHz        44.03           0.28             10        54.35        65.95      -11.6

All other results were greater than 20 dB below the limit.




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                      Page 5 of 8
(866) 311-3268 phone, (480) 926-3598 fax                                          p0910004, d0940010 Rev 1.0


                                Radiated Emissions Test Setup Photos




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                           Page 6 of 8
(866) 311-3268 phone, (480) 926-3598 fax                               p0910004, d0940010 Rev 1.0


                             AC Conducted Emissions Test Setup Photos




Flom Test Lab
3356 North San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                            Page 7 of 8
(866) 311-3268 phone, (480) 926-3598 fax                                p0910004, d0940010 Rev 1.0


                                            Test Equipment Utilized

     Description         MFG         Model Number            FTL Asset Number       Last Cal Date    Cal Due Date
 Spectrum Analyzer        HP             8546A                    i00033              10/14//08       10/14//09
 Spectrum Analyzer        HP             8566B                    i00049               8/22/08          8/22/09
 Bi-conical Antenna     EMCO             3109B                    i00088              10/16/07         10/16/09
Log Periodic Antenna     Aprel            2001                    i00089              10/22/07         10/22/09
        LISN             FCC       FCC-LISN-50-32-2-01            i00270               9/17/08          9/17/10

  In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the
  described equipment. Prior to testing these components were tested to verify proper operation.




  END OF TEST REPORT




  Flom Test Lab
  3356 North San Marcos Place, Suite 107
  Chandler, Arizona 85225-7176                                                                   Page 8 of 8
  (866) 311-3268 phone, (480) 926-3598 fax                                       p0910004, d0940010 Rev 1.0



Document Created: 2009-05-13 10:49:32
Document Modified: 2009-05-13 10:49:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC