Test Report

FCC ID: TMEMF4100X004

Test Report

Download: PDF
FCCID_1208535

Date:                              September 28, 2009

Federal Communications Commission
Via: Electronic Filing


Attention:                         Authorization & Evaluation Division

Applicant:                         Blackboard, Inc.
Equipment:                         MF4100
FCC ID:                            TMEMF4100X004
FCC Rules:                         15.225

Gentlemen:

On behalf of the Applicant, enclosed please find Application Form 731, Engineering Test Report and all pertinent
documentation, the whole for approval of the referenced equipment as shown.

We trust the same is in order. Should you need any further information, kindly contact the writer who is authorized
to act as agent.




                                                                    Sincerely yours,




                                                                    John Erhard: Engineering Manager




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                  p0990007, d0990014 Rev 1.0


List Of Exhibits
                              (FCC Certification (Transmitters) - Revised 9/28/98)

Applicant:                           Blackboard, Inc.

FCC ID:                              TMEMF4100X004


By Applicant:


                   1. Letter Of Authorization

                   2. Identification Drawings
                                Id Label
                               Location Info
                                Attestation Statement(S)
                               Location of Compliance Statement

                   3. Documentation: 2.1033(B)
                          (3)     User Manual(S)
                          (4)     Operational Description
                          (5)     Block Diagram
                          (5)     Schematic Diagram
                          (7)     External Photographs
                                  Internal Photographs
                                  Parts List
                                  Active Devices


By Compliance Testing


                   A.      Testimonial & Statement of Certification

                   B.      Statement of Qualifications




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                  p0990007, d0990014 Rev 1.0


                                            Test Report
                                                   for

                                       FCC ID: TMEMF4100X004

                                            Model: MF4100

                                                   to

                                  Federal Communications Commission

                                           Rule Part(s)15.225

                                   Date Of Report: September 28, 2009


On the Behalf of the Applicant:    Blackboard, Inc.
                                   22601 North 19th Ave, Suite 200
                                   Phoenix, AZ 85027


Attention of:                      Tom Kuestersteffen
                                   623-476-1263
                                   email: tkuestersteffen@blackboard.com
                                   and/or Tim Mattson
                                   623-476-1400




Supervised By:                                                  John Erhard: Engineering Manager




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                             p0990007, d0990014 Rev 1.0


                                  Test Report Revision History
Revision          Date                          Revised By              Reason for revision
1.0               September 28, 2009            J. Erhard               Original Document




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                     p0990007, d0990014 Rev 1.0


                            The applicant has been cautioned as to the following:

15.21            Information to User.

The users manual or instruction manual for an intentional radiator shall caution the user that changes or
modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.

15.27(a)         Special Accessories.

Equipment marketed to a consumer must be capable of complying with the necessary regulations in the
configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or
special connectors are required to enable an unintentional or intentional radiator to comply with the emission
limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories.
However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the
responsible party may employ other methods of ensuring that the special accessories are provided to the
consumer, without additional charge.

Information detailing any alternative method used to supply the special accessories for a grant of equipment
authorization or retained in the verification records, as appropriate. The party responsible for the equipment, as
detailed in § 2.909 of this chapter, shall ensure that these special accessories are provided with the equipment.
The instruction manual for such devices shall include appropriate instructions on the first page of text concerned
with the installation of the device that these special accessories must be used with the device. It is the
responsibility of the user to use the needed special accessories supplied with the equipment.




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                   p0990007, d0990014 Rev 1.0


                             Testimonial And Statement Of Certification


This is to certify that:


        1.       That the application was prepared either by, or under the direct supervision of, the undersigned.

        2.       That the technical data supplied with the application was taken under my direction and
                 supervision.

        3.       That the data was obtained on representative units, randomly selected.

        4.       That, to the best of my knowledge and belief, the facts set forth in the application and
                 accompanying technical data are true and correct.




Certifying Engineer:                                                John Erhard: Engineering Manager



Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                  p0990007, d0990014 Rev 1.0


                                            Table Of Contents

Rule                  Description                                                              Page

                      Test Report                                                                 1
2.1033(c)             General Information Required                                                2
                      Standard Test Conditions and Engineering Practices                          4
                      Test Results Summary                                                        5
15.225(a)(b)(c)(d)    Field Strength                                                              6
15.225(e)             Frequency Stability                                                         7
15.209                Radiated Emissions                                                          8
15.207.                Powerline Conducted Emissions                                              9
RSS 210               99% Occupied Bandwidth                                                     13
.                     Test Equipment Utilized                                                    14




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                          p0990007, d0990014 Rev 1.0


Required information per ISO 17025-2005, paragraph 5.10.2:
a)                                            Test Report

b) Laboratory:                 Compliance Testing
 (FCC: 31040/SIT)              3356 N. San Marcos Place, Suite 107
 (Canada: IC 2044A-1)          Chandler, AZ 85225

c) Report Number:              d0990014

d) Client:                     Blackboard, Inc.

e) Identification:             MF4100

  Description:                 13.56 MHz Transmitter

f) EUT Condition:              Not required unless specified in individual tests.

g) Report Date:                September 28, 2009

h, j, k):                      As indicated in individual tests.

i) Sampling method:            No sampling procedure used.

l) Uncertainty:                In accordance with Compliance Testing internal quality manual.

m) Supervised by:




                                                                           John Erhard: Engineering Manager

n) Results:                    The results presented in this report relate only to the item tested.

o) Reproduction:               This report must not be reproduced, except in full, without written permission
                               from this laboratory.




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                   Page 1 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                        p0990007, d0990014 Rev 1.0


                          List Of General Information Required For Certification

               In Accordance with FCC Rules and Regulations, Volume II, Part 2 and to 15.225

Sub-Part 2.1033
(c)(1):

Name and Address of Applicant:             Blackboard, Inc.

(c)(2):   FCC ID:                          TMEMF4100X004

          Model Number:                    MF4100

(c)(3):   Instruction Manual(s):

                          Please See Attached Exhibits

(c)(4):   Type of Emission:                ASK

(c)(5):   FREQUENCY RANGE, MHz:            13.56


(c)(6):   Power Rating, W:                 70 femto W
                       Switchable                       Variable              X    N/A

(c)(7):   Maximum Power Rating, W:         5 micro W

15.203: Antenna Requirement:
                                       X       The antenna is permanently attached to the EUT
                                               The antenna uses a unique coupling
                                               The EUT must be professionally installed
                                               The antenna requirement does not apply




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                     Page 2 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                          p0990007, d0990014 Rev 1.0


Subpart 2.1033 (continued)

(c)(8):   Circuit Diagram/Circuit Description:
                  Including description of circuitry & devices provided for determining and stabilizing
                  frequency, for suppression of spurious radiation, for limiting modulation and limiting power.

                           Please See Attached Exhibits

(c)(9):   Label Information:

                           Please See Attached Exhibits

(c)(10): Photographs:

                           Please See Attached Exhibits

(c)(11): Digital Modulation Description:

                           ___ Attached Exhibits
                           _X_ N/A

(c)(12): Test And Measurement Data:

                           Follows




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                        Page 3 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                             p0990007, d0990014 Rev 1.0


Sub-part
2.1033(b):                                 Test And Measurement Data

All tests and measurement data shown were performed in accordance with FCC Rules and Regulations,
Volume II; Part 2 and the following individual Parts, 15.225.


                          Standard Test Conditions and Engineering Practices

Except as noted herein, the following conditions and procedures were observed during the testing:

In accordance with ANSI C63.4-2003 unless otherwise indicated in the specific measurement results, the
ambient temperature of the actual EUT was maintained within the range of 10 to 40C (50 to 104 F) unless
the particular equipment requirements specify testing over a different temperature range. Also, unless
otherwise indicated, the humidity levels were in the range of 10% to 90% relative humidity.


Measurement results, unless otherwise noted, are worst-case measurements.


A2LA

“A2LA has accredited Compliance Testing in Chandler, AZ for technical competence in the field of
Electrical testing. The accreditation covers the specific tests and types of tests listed on the agreed scope
of accreditation. This laboratory meets the requirements of ISO 17025:2005 ‘General Requirements for
the Competence of Testing and Calibration Laboratories’ and any additional program requirements in the
identified field of testing.”

Please refer to www.a2la.org for current scope of accreditation.

Certificate number: 2152.01




FCC OATS Reg. #933597

IC Reg. # 2044A-1




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                    Page 4 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                         p0990007, d0990014 Rev 1.0


                                      Test Results Summary

        Specification                     Test Name              Pass, Fail, N/A   Comments
          15.225(a)              Fundamental Field Strength          Pass
        15.225(b)(c)(d)         Out of Band Spurious Emissions       Pass
          15.225(e)                    Frequency Stability           Pass
            12.209                    Radiated Emissions             Pass
            12.207              Conducted Powerline Emissions        Pass
           RSS-210                99% Occupied Bandwidth             Pass




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                          Page 5 of 14
(866) 311-3268 phone, (480) 926-3598 fax                               p0990007, d0990014 Rev 1.0


 Name of Test:                    Field Strength
 Specification:                   15.225(a)(b)(c)(d)                        Engineer: J. Erhard
 Test Equipment Utilized          i00033, i00326                            Test Date: 9/24/2009

                                              Test Procedure

 The UUT was tested on an anechoic chamber at a distance of 1 meter from the receiving loop antenna. The
 EUT was rotated 360 degrees with the receiving antenna on the X, Y, and Z-axis. A spectrum analyzer was
 used to verify that the UUT met the requirements for Fundamental Field Strength. The antenna correction
 and distance correction factors were summed with the quasi-peak measurement to ensure accurate readings
 were obtained. The following table indicates the highest emission in each of the indicated bands.

                                                 Test Setup


                            UUT                        Antenna                   Spectrum
                                                                                 Analyzer



                                               Field Strength

  Frequency        Measured          Monitored         Distance   Antenna    Corrected        Limit    Result
     Band          Frequency           Level           CF (dB)    CF (dB)   Measurement     (dBuV/m)
    (MHz)            (MHz)           (dBuV/m)                                (dBuV/m)
13.110_13.410      13.348453           59.88            59.1       17.8        -17.02        40.51     Pass
13.410_13.553      13.54916            60.41            59.1       17.8        -16.49        50.47     Pass
13.553_13.567      13.56007            82.05            59.1       17.8         5.15         84.00     Pass
13.567_13.710      13.56871            63.79            59.1       17.8        -13.11        50.47     Pass
13.710_14.010       13.8602            32.36            59.1       17.8        -44.54        40.51     Pass

       Note. Cable correction factors are not included in this measurement as the low loss of the high
         quality TWINAX cable at low frequencies in practically non-existent.




 Compliance Testing
 3356 N. San Marcos Place, Suite 107
 Chandler, Arizona 85225-7176                                                                    Page 6 of 14
 (866) 311-3268 phone, (480) 926-3598 fax                                         p0990007, d0990014 Rev 1.0


Name of Test:                                      Frequency Stability
Specification:                                     15.225(e)                                  Engineer: J. Erhard
Test Equipment Utilized                            i00019, i00027, i00108, i00319             Test Date: 9/24/2009

                                                                     Test Procedure

The UUT was placed in an environmental test chamber and a frequency counter was utilized to verify that the
frequency stability met the requirement for frequency stability across the temperature range from –20°C to
+50°C. A variable power supply was used to vary the voltage from 85% to 115% of the rated voltage.

                                                                       Test Setup


                                              Power                            UUT                  Frequency
                                              Supply                                                 Counter



                                            Frequency Stability vs. Temperature

                             13.56150

                             13.56100
           Frequency (MHz)




                             13.56050                                                                 Upper Limit
                                                                                                      Measured Frequency
                             13.56000
                                                                                                      Low er Limit
                             13.55950

                             13.55900

                             13.55850
                                     -20     -10       0        10      20       30   40     50
                                                    Tem perature (Centigrade)




                                                           Frequency Stability vs. Voltage

                             13.56150

                             13.56100
       Frequency (MHz)




                             13.56050
                                                                                                       Upper Limit
                             13.56000                                                                  Measured Frequency
                                                                                                       Low er Limit
                             13.55950

                             13.55900

                             13.55850
                                    93.50              104.50                115.50        126.50
                                                                Voltage




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                                       Page 7 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                                            p0990007, d0990014 Rev 1.0


Name of Test:                   Radiated Emissions
Specification:                  15.209                                  Engineer: J. Erhard
Test Equipment Utilized         i00049, i00267                          Test Date: 9/24/2009

                                            Test Procedure

The UUT was tested on an Open Area Test Site (OATS) at a distance of 3 meters from the receiving
antenna. A spectrum analyzer was used to verify that the UUT met the requirements for Radiated Emissions.
The spectrum for each tuned frequency was examined beyond the 10th harmonic.

                                              Test Setup


                            UUT                      Antenna                     Spectrum
                                                                                 Analyzer


                                         Radiated Emissions

     Emission Freq    Measured Value     Correction Factor     Corrected Value       Limit     Margin
        (MHz)           (dBuV/m)               (dB)               (dBuV/m)         (dBuV/m)      dB
        41.660            12.8                 12.8                 25.6             40.0      -14.4
       142.956            15.3                 13.9                 29.2             43.0      -13.8
       170.910            28.1                 12.1                 40.2             43.0       -2.8
       221.030            18.7                 12.3                 31.0             46.0      -15.0
       285.988            24.8                 15.0                 39.8             46.0       -6.2
       337.977            23.8                 16.7                 40.5             46.0       -5.5




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                    Page 8 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                         p0990007, d0990014 Rev 1.0


 Name of Test:                        Powerline Conducted Emissions
 Specification:                       15.207                                       Engineer: J. Erhard
 Test Equipment Utilized              i00033, i00270                               Test Date: 9/24/2009

                                                   Test Procedure

 The UUT power cable connected to a LISN and the monitored output of the LISN was connected directly to a
 spectrum analyzer. The conducted emissions from 150 kHz to 30 MHz were monitored and compared to the
 specification limits. The average measurements were the worst-case and are recorded in the tables below.

                                                     Test Setup

                                                                          Spectrum
                                                                          Analyzer
                                        LISN

                                                                            UUT
                                                                         Power Cable


                                 Conducted Emissions Line 1 Neutral Peak Graph
                                                                                                    Points of Interest
                                            Compliance Testing                                      Corrected Peak Data
                                         Conducted Emissions - Class B                              CISPRB_QP
                                               Line 1 (Neutral)                                     CISPRB_AV
                      100.0

                       90.0

                       80.0
     Amplitude dBuV




                       70.0

                       60.0

                       50.0

                       40.0

                       30.0

                       20.0

                       10.0

                         0
                        100.0K             1.0M                           10.0M                                 100.0M

Operator: JE                                          Frequency MHz
Wall Wort.TIL                                                                     Job #: p0990007


                                 Conducted Emissions Line 2 Neutral Peak Graph
                                                                                                    Corrected Peak Data
                                             Compliance Testing                                     CISPRB_AV
                                         Conducted Emissions - Class B                              CISPRB_QP
                                                Line 2 (Phase)                                      Points of Interest
                      100.0

                       90.0

                       80.0
     Amplitude dBuV




                       70.0

                       60.0

                       50.0

                       40.0

                       30.0

                       20.0

                       10.0

                         0
                        100.0K             1.0M                           10.0M                                 100.0M

Operator: JE                                          Frequency MHz
Wall Wort.TIL                                                                     Job #: p0990007




 Compliance Testing
 3356 N. San Marcos Place, Suite 107
 Chandler, Arizona 85225-7176                                                                            Page 9 of 14
 (866) 311-3268 phone, (480) 926-3598 fax                                                 p0990007, d0990014 Rev 1.0


                                   Line 1 Neutral AVG Detector
Frequency        Uncorrected   LISN       Cable      Attenuator   Final L1      Limit       AVG
(MHz)            Data          Corr       Loss       (dB)                                   Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
13.559 MHz       35.99         0.00       0.692      10.000       46.682        50.000      -3.318
192.97 KHz       18.15         0.20       0.011      10.000       28.361        54.772      -26.411
187.53 KHz       16.77         0.20       0.004      10.000       26.971        54.928      -27.957
150.95 KHz       14.12         0.29       0.041      10.000       24.454        55.973      -31.518
150.65 KHz       14.34         0.29       0.041      10.000       24.671        55.982      -31.310
150.33 KHz       14.32         0.30       0.038      10.000       24.654        55.991      -31.336

                                    Line 2 Phase AVG Detector
Frequency        Uncorrected   LISN        Cable    Attenuator    Final L2      Limit       AVG
(MHz)            Data          Corr        Loss     (dB)                                    Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
13.56 MHz        34.63         0.00        0.691    10.000        45.321        50.000      -4.679
194.48 KHz       21.16         0.20        0.011    10.000        31.371        54.729      -23.358
193.01 KHz       21.53         0.20        0.011    10.000        31.741        54.771      -23.030
192.25 KHz       21.24         0.20        0.012    10.000        31.452        54.793      -23.341
190.51 KHz       21.13         0.20        0.008    10.000        31.341        54.843      -23.501
151.83 KHz       15.41         0.28        0.041    10.000        25.730        55.948      -30.218

                                    Line 1 Neutral QP Detector
Frequency        Uncorrected   LISN        Cable     Attenuator   Final L1      Limit       QP
(MHz)            Data          Corr        Loss      (dB)                                   Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
13.559 MHz       45.280        0.000       0.692     10.000       55.972        60.000      -4.028
192.97 KHz       35.150        0.200       0.011     10.000       45.361        64.772      -19.411
187.53 KHz       34.310        0.200       0.004     10.000       44.514        64.928      -20.414
150.95 KHz       31.940        0.291       0.041     10.000       42.271        65.973      -23.702
150.65 KHz       32.010        0.294       0.041     10.000       42.344        65.982      -23.637
150.33 KHz       32.000        0.297       0.038     10.000       42.334        65.991      -23.656

                                    Line 2 Phase QP Detector
Frequency        Uncorrected   LISN       Cable     Attenuator    Final L2      Limit       QP
(MHz)            Data          Corr       Loss      (dB)                                    Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
13.56 MHz        44.46         0.00       0.691     10.000        55.151        60.000      -4.849
194.48 KHz       35.26         0.20       0.011     10.000        45.471        64.729      -19.258
193.01 KHz       35.15         0.20       0.011     10.000        45.361        64.771      -19.410
192.25 KHz       35.71         0.20       0.012     10.000        45.922        64.793      -18.871
190.51 KHz       35.69         0.20       0.008     10.000        45.898        64.843      -18.945
151.83 KHz       32.04         0.28       0.041     10.000        42.363        65.948      -23.585




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                               Page 10 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                     p0990007, d0990014 Rev 1.0


                                       Conducted Emissions Power Over Ethernet Option

                                         Conducted Emissions Line 1 Neutral Peak Graph
                                                                                                              Points of Interest
                                                       Compliance Testing                                     Corrected Peak Data
                                                    Conducted Emissions - Class B                             CISPRB_QP
                                                          Line 1 (Neutral)                                    CISPRB_AV
                           100.0

                            90.0

                            80.0
          Amplitude dBuV




                            70.0

                            60.0

                            50.0

                            40.0

                            30.0

                            20.0

                            10.0

                              0
                             100.0K                   1.0M                          10.0M                                 100.0M

     Operator: LR                                                Frequency MHz
     Cond Emissions.TIL                                                                     Job #: p099007




                                         Conducted Emissions Line 2 Neutral Peak Graph
                                                                                                                Corrected Peak Data
                                                         Compliance Testing                                     CISPRB_AV
                                                    Conducted Emissions - Class B                               CISPRB_QP
                                                           Line 2 (Phase)                                       Points of Interest
                           100.0

                            90.0

                            80.0
          Amplitude dBuV




                            70.0

                            60.0

                            50.0

                            40.0

                            30.0

                            20.0

                            10.0

                               0
                              100.0K                  1.0M                           10.0M                                  100.0M

     Operator: LR                                                 Frequency MHz
     Cond Emissions.TIL                                                                      Job #: p099007




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                                    Page 11 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                                          p0990007, d0990014 Rev 1.0


                                   Line 1 Neutral AVG Detector

Frequency        Uncorrected   LISN        Cable     Attenuator   Final L1      Limit       AVG
(MHz)            Data          Corr        Loss      (dB)                                   Margin
                 (dBuV)        Fact (dB)   (dB)                                             (dB)
154.72 KHz       16.17         0.25        0.039     10.000       26.465        55.865      -29.400
153.04 KHz       16.13         0.27        0.041     10.000       26.444        55.913      -29.469
152.24 KHz       15.92         0.28        0.039     10.000       26.240        55.936      -29.696
151.12 KHz       16.02         0.29        0.041     10.000       26.353        55.968      -29.615
150.24 KHz       16.24         0.30        0.039     10.000       26.573        55.993      -29.420
150.08 KHz       16.55         0.30        0.043     10.000       26.893        55.998      -29.105

                                    Line 2 Phase AVG Detector
Frequency        Uncorrected   LISN        Cable    Attenuator    Final L2      Limit       AVG
(MHz)            Data          Corr        Loss     (dB)                                    Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
13.558 MHz       26.71         0.00        0.694    10.000        37.400        50.000      -12.600
2.8115 MHz       15.44         0.00        0.318    10.000        25.758        46.000      -20.242
2.7835 MHz       16.38         0.00        0.312    10.000        26.695        46.000      -19.305
2.7643 MHz       17.24         0.00        0.319    10.000        27.556        46.000      -18.444
155.12 KHz       22.58         0.25        0.042    10.000        32.874        55.854      -22.980
150.05 KHz       23.66         0.30        0.043    10.000        34.003        55.998      -21.996

                                    Line 1 Neutral QP Detector
Frequency        Uncorrected   LISN        Cable     Attenuator   Final L1      Limit       QP
(MHz)            Data          Corr        Loss      (dB)                                   Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
154.72 KHz       30.930        0.253       0.039     10.000       41.222        65.865      -24.643
153.04 KHz       30.420        0.270       0.041     10.000       40.731        65.913      -25.183
152.24 KHz       30.610        0.278       0.039     10.000       40.926        65.936      -25.010
151.12 KHz       30.760        0.289       0.041     10.000       41.090        65.968      -24.878
150.24 KHz       31.010        0.298       0.039     10.000       41.347        65.993      -24.647
150.08 KHz       31.420        0.299       0.043     10.000       41.763        65.998      -24.235

                                    Line 2 Phase QP Detector
Frequency        Uncorrected   LISN       Cable     Attenuator    Final L2      Limit       QP
(MHz)            Data          Corr       Loss      (dB)                                    Margin
                 (dBuV)        Fact (dB) (dB)                                               (dB)
13.558 MHz       34.49         0.00       0.694     10.000        45.184        60.000      -14.816
2.8115 MHz       25.01         0.00       0.318     10.000        35.328        56.000      -20.672
2.7835 MHz       25.10         0.00       0.312     10.000        35.412        56.000      -20.588
2.7643 MHz       25.23         0.00       0.319     10.000        35.549        56.000      -20.451
155.12 KHz       30.74         0.25       0.042     10.000        41.030        65.854      -24.823
150.05 KHz       30.81         0.30       0.043     10.000        41.153        65.998      -24.846




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                               Page 12 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                     p0990007, d0990014 Rev 1.0


Name of Test:                   99% Occupied Bandwidth
Specification:                  RSS 210 Industry Canada Only         Engineer: J. Erhard
Test Equipment Utilized         i00033, i00326                       Test Date: 9/24/2009

                                           Test Procedure

The UUT was tested on an anechoic chamber at a distance of 1 meter from the receiving loop antenna. A
spectrum analyzer was used to measure the 99% occupied bandwidth.

                                             Test Setup


                          UUT                   Antenna                   Spectrum
                                                                          Analyzer


                                     99% Bandwidth Summary

                          Frequency MHz     Recorded Measurement      Result
                              13.56                600 kHz            Pass




                                                                                            600




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                             Page 13 of 14
(866) 311-3268 phone, (480) 926-3598 fax                                   p0990007, d0990014 Rev 1.0


                                           Test Equipment Utilized

      Description         MFG         Model Number          FTL Asset Number      Last Cal Date    Cal Due Date
 Frequency Counter         HP              5334B                 i00019              1/26/09          1/26/11
Temperature Chamber      Tenney          Tenney Jr               i00027              12/8/08          12/8/09
  Spectrum Analyzer        HP             85462A                 i00033             10/14/08         10/14/09
  Spectrum Analyzer        HP              8566B                 i00049             12/04/08         12/04/09
        Variac          Powerstat         3PN126                 i00108                NCR              NCR
   Bi-Log Antenna       Schaffner       CBL6111C                 i00267              11/6/07         11/6/09
         LISN             FCC       FCC-LISN-50-32-2-01          i00270              9/17/08          9/17/10
         DMM              Fluke             87 III               i00319              12/5/08          12/5/09
 Active Loop Antenna     EMCO               6507                 i00326               4/1/09           4/1/11


    In addition to the above listed equipment standard RF connectors and cables were utilized in the testing
    of the described equipment. Prior to testing these components were tested to verify proper operation.




    END OF TEST REPORT




    Compliance Testing
    3356 N. San Marcos Place, Suite 107
    Chandler, Arizona 85225-7176                                                               Page 14 of 14
    (866) 311-3268 phone, (480) 926-3598 fax                                     p0990007, d0990014 Rev 1.0



Document Created: 2009-11-11 11:50:16
Document Modified: 2009-11-11 11:50:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC