MPE

FCC ID: TLZ-WH029T

RF Exposure Info

Download: PDF
FCCID_1651285

                 FCC Test Report                                                       Report No. : FR221716


3.10 Maximum Permissible Exposure
3.10.1 Limit of Maximum Permissible Exposure
                                Limits for Occupational / Controlled Exposure
                                                                                            Averaging Time
 Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                             |E|²,|H|² or S
         (MHz)             Strength (E) (V/m)    Strength (H) (A/m)      (mW/ cm²)
                                                                                               (minutes)
        0.3-3.0                   614                   1.63               (100)*                    6
        3.0-30                  1842 / f              4.89 / f            (900 / f)*                 6
        30-300                   61.4                  0.163                  1.0                    6
       300-1500                                                            F/300                     6
    1500-100,000                                                              5                      6
                            Limits for General Population / Uncontrolled Exposure
                                                                                            Averaging Time
 Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                             |E|²,|H|² or S
         (MHz)             Strength (E) (V/m)    Strength (H) (A/m)      (mW/ cm²)
                                                                                               (minutes)
       0.3-1.34                   614                   1.63               (100)*                    30
        1.34-30                  824/f                 2.19/f              (180/f)*                  30
        30-300                   27.5                  0.073                  0.2                    30
       300-1500                                                            F/1500                    30
    1500-100,000                                                              1.0                    30
 NOTE 1: f = frequency in MHz ; *Plane-wave equivalent power density
 NOTE 2: For the applicable limit, see FCC 1.1310

3.10.2 MPE Calculation Method
                                                                          2
              30  P  G
E (V/m) =                                  Power Density:   Pd (W/m²) = E
                  d                                                     377
E = Electric field (V/m)
P = RF output power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to

Pd = 30  P  G
      377  d 2




SPORTON INTERNATIONAL INC.                                                 Page No.           : 56 of 66
TEL : 886-2-2696-2468                                                      Report Version     : 01
FAX : 886-2-2696-2255                                                      FCC ID              TLZ-WH029T


                FCC Test Report                                                       Report No. : FR221716


3.10.3 Result of Maximum Permissible Exposure
 Exposure Environment:       General Population / Uncontrolled Exposure
                                               Test results

                                 Average          Average       Power           Separation        Limit of
 Maximum EIPR Power of                                                                             Power
                               EIRP Power     EIRP Power      Density (S)          Distance      Density (S)
       Test Frequency:
                                 (dBm)             (mW)       (mW/cm²)               (cm)        (mW/cm²)

     LRP       62.80 GHz          23.27           212.1930     0.042236               20             1.00
    HRP        60.48 GHz          31.49       1408.1769        0.280290               20             1.00
 Measurement uncertainty:      ±2.7    dB
 NOTE: For the applicable limit, see FCC 1.1310




SPORTON INTERNATIONAL INC.                                                Page No.            : 57 of 66
TEL : 886-2-2696-2468                                                     Report Version      : 01
FAX : 886-2-2696-2255                                                     FCC ID               TLZ-WH029T



Document Created: 2012-03-06 17:23:24
Document Modified: 2012-03-06 17:23:24

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC