D4: SYSTEM VALIDATION DIPOLE


   y    M                                                            $49upe
Calibration Laboratory of                                        s“\\\\_//l/”/l;                                   Schweizerischer Kalibrierdienst
Schmid & Partner                                                 i‘afimfi                                            Service suisse d‘étalonnage
  Engineering AG                                                 zs                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                     z,{/fl\\y‘                                         Swiss Calibration Service
                                                                     thilabs®

Accredited by the Swiss Accreditation Service (SAS)                                             Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Client       BV—ADT (Auden)                                                                     Certificate No: D2450V2—716_Mar09

CALIBRATION CERTIFICATE
m



 Object                                D2450V2 — SN: 716


 Calibration procedure(s)              QA CAL—05.v7
                                       Calibration procedure for dipole validation kits




 Calibration date:                     March 17, 2009

 Condition of the calibrated item      In Tolerance

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                      Cal Date (Calibrated by, Certificate No.)             Scheduled Calibration
 Power meter EPM—442A                   GB37480704                08—Oct—08 (No. 217—00898)                             Oct—09
 Power sensor HP 8481A                  US37202783                08—Oct—08 (No. 217—00898)                             Oct—09
 Reference 20 dB Attenuator             SN: 5086 (20g)            01—Jul—08 (No. 217—00864)                             Jul—09
 Type—N mismatch combination            SN: 5047.2 / 06327        01—Jul—08 (No. 217—00887)                             Jul—09
 Reference Probe ES3DV2                 SN: 3025                  28—Apr—08 (No. ES3—3025_Apr08)                        Apr—09
 DAE4                                   SN: 601                   07—Mar—09 (No. DAE4—601_Mar09)                        Mar—10


 Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
 Power sensor HP 8481A                  MY41092317                18—Oct—02 (in house check Oct—07)                     In house check: Oct—09
 RF generator R&S SMT—06                100005                    4—Aug—99 (in house check Oct—07)                      In house check: Oct—09
 Network Analyzer HP 8753E              US37390585 $4206          18—Oct—01 (in house check Oct—08)                     In house check: Oct—09



                                        Name                                    Function                                Signature

                                                                                                                   ’,".F/J &
 Calibrated by:                         Jeton Kastrati                          Laboratory Technician



 Approved by:                           Katia Pokovic                           Technical Manager



                                                                                                                       Issued: March 18, 2009
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.



Certificate No: D2450V2—716_NMar09                                    Page 1 of 9


Calibration
      ‘     Laboratory of                                    i/7y
                                                            \\\\\\/_// >         S    Schweizerischer Kalibrierdienst
Schmid & Partner                                            m                    Cc   Service suisse d‘étalonnage
  Engineering AG                                            ;///%\;                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                 ’r/,// //\ \\\\\‘   S    Swiss Calibration Service
                                                                 itite


Accredited by the Swiss Accreditation Service (SAS)                               Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


Glossary:
TSL                          tissue simulating liquid
ConvF                        sensitivity in TSL / NORM x,y,z
N/A                          not applicable or not measured

Calibration is Performed According to the Following Standards:
    a) IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—
       Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
         Communications Devices: Measurement Techniques", December 2003
    b) IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) for hand—held
         devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)",
       February 2005
    c) Federal Communications Commission Office of Engineering & Technology (FCC OET),
       "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency
       Electromagnetic Fields; Additional Information for Evaluating Compliance of Mobile and
         Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions",
         Supplement C (Edition 01—01) to Bulletin 65

Additional Documentation:
    d) DASY4/5 System Handbook

Methods Applied and Interpretation of Parameters:
   e Measurement Conditions: Further details are available from the Validation Report at the end
     of the certificate. All figures stated in the certificate are valid at the frequency indicated.
    e    Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
         point exactly below the center marking of the flat phantom section, with the arms oriented
         paralle!l to the body axis.
    e    Feed Point Impedance and Return Loss: These parameters are measured with the dipole
         positioned under the liquid filled phantom. The impedance stated is transformed from the
         measurement at the SMA connector to the feed point. The Return Loss ensures low
         reflected power. No uncertainty required.
    e    Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
         No uncertainty required.
    e    SAR measured: SAR measured at the stated antenna input power.
    e    SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
         connector.
    «_   SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
         nominal SAR result.


Certificate No: D2450V2—716_Mar09                                Page 2 of 9


Measurement Conditions
    DASY system configuration, as far as not given on page 1.
       DASY Version                                               DASY5                                 V5.0
       Extrapolation                                     Advanced Extrapolation

       Phantom                                          Modular Flat Phantom V5.0
       Distance Dipole Center — TSL                                10 mm                             with Spacer

      Zoom Scan Resolution                                  dx, dy, dz =5 mm
       Frequency                                            2450 MHz # 1 MHz



Head TSL parameters
    The following parameters and calculations were applied.
                                                                  Temperature         Permittivity        Conductivity
       Nominal Head TSL parameters                                    22.0 °C            39.2              1.80 mho/m
       Measured Head TSL parameters                               (22.0 £ 0.2) °C     38.0 4 6 %        1.82 mhoim * 6 %

       Head TSL temperature during test                           (21.0 £0.2) °C



SAR result with Head TSL

      SAR averaged over 1 cm‘ (1 g) of Head TSL                     Condition
      SAR measured                                            250 mW input power                   13.5 mW /g
      SAR normalized                                           normalized to 1W                    54.0 mW / g
      SAR for nominal Head TSL parameters ‘                    normalized to 1W           53.3 mW ig £ 17.0 % (k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                   condition
      SAR measured                                            250 mW input power                   6.24 mW / g
      SAR normalized                                           normalized to 1W                    25.0 mW / g
      SAR for nominal Head TSL parameters ‘                    normalized to 1W           24.8 mW 1g £ 16.5 % (k=2)




* Correction to nominal TSL parameters according to d), chapter "SAR Sensitivities"

Certificate No: D2450V2—716_Mar09                          Page 3 of 9


Body TSL parameters
     The following parameters and calculations were applied.
                                                                   Temperature        Permittivity        Conductivity
       Nominal Body TSL parameters                                    22.0 °C            52.7              1.95 mho/m

       Measured Body TSL parameters                               (22.0 £0.2) °C      54.3 £ 6 %        1.99 mho/m * 6 %

       Body TSL temperature during test                           (21.1 £0.2) °C          wee                    ~——



SAR result with Body TSL

       SAR averaged over 1 em‘ (1 g) of Body TSL                    Condition
       SAR measured                                           250 mW input power                   13.3 mW /g

       SAR normalized                                           normalized to 1W                   53.2 mW /g
       SAR for nominal Body TSL parameters *                    normalized to 1W          52.9 mW ig # 17.0 % (k=2)


       SAR averaged over 10 cm* (10 g) of Body TSL                  condition
       SAR measured                                           250 mW input power                   6.24 mW / g
       SAR normalized                                           normalized to 1W                   25.0 mW 1g
       SAR for nominal Body TSL parameters *                    normalized to 1W          25.0 mW ig * 16.5 % (k=2)




* Correction to nominal TSL parameters according to d), chapter "SAR Sensitivities"

Certificate No: D2450V2—716_Mar09                          Page 4 of 9


Appendix

Antenna Parameters with Head TSL

      Impedance, transformed to feed point                                           54.9 Q +1.4jQ

      Return Loss                                                                       —26.2 dB


Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                           50.2 Q + 4.3 jQ

      Return Loss                                                                       —27 .4 dB




General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.144 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                    SPEAG

      Manufactured on                                                              September 10, 2002




Certificate No: D2450V2—716_Mard®                        Page 5 of 9


DASYS5 Validation Report for Head TSL
                                                                                Date/Time: 17.03.2009 15:42:29

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN716

Communication System: CW; Frequency: 2450 MHz; Duty Cyele: 1:1
Medium: HSL U1O BB
Medium parameters used: £= 2450 MHz; 0 = 1.83 mho/m; & = 38.1; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC)

DASYS5 Configuration:
        Probe: ES3DV2 — SN3025; ConvF(4.4, 4.4, 4.4); Calibrated: 28.04.2008

        Sensor—Surface: 3.4mm (Mechanical Surface Detection)

        Electronics: DAE4 $n601; Calibrated: 07.03.2009

        Phantom: Flat Phantom 5.0 (front); Type: QDOOOPS0AA: Serial: 1001

        Measurement SW: DASY5, V5.0 Build 120; SEMCAD X Version 13.4 Build 45


Pin = 250 mW; d = 10 mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 96.5 V/m; Power Drift = 0.040 dB
Peak SAR (extrapolated) =28.2 W/kg
SAR(1 g) = 13.5 mW/g; SAR(10 g) = 6.24 mW/g
Maximum value of SAR (measured) =16.1 mW/g




         —13.4



         ~17.9



         —22.4


                    0 dB = 16.ImW/g



Certificate No: D2450V2—716_Mar09                         Page 6 of 9


Impedance Measurement Plot for Head TSL


                                                          17 Mar 2009      11142132
[CHI) sii     1 U FS          1: 54.941 8   1.4121 e   91.732 pH         2 450,.000 000 MHz




Del

Cor




CH2



Del

Cor




fAv
16



            START 2 250.000 000 MHz                                STOP 2 650.000 000 MHz




Certificate No: D2450V2—716_Mar09                        Page 7 of 9


DASY5 Validation Report for Body TSL
                                                                                  Date/Time: 10.03.2009 14:20:02

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN:716
Communication System: CW; Frequency: 2450 MHz; Duty Cycle: 1:1
Medium: MSL U1O0 BB
Medium parameters used: £ = 2450 MHz; o = 2 mho/m; &, = 54.4; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC)

DASY5 Configuration:
        Probe: ES3DV2 — SN3025; ConvF(4.07, 4.07, 4.07); Calibrated: 28.04.2008

        Sensor—Surface: 3.4mm (Mechanical Surface Detection)

        Electronics: DAE4 Sn601; Calibrated: 07.03.2009

        Phantom: Flat Phantom 5.0 (back); Type: QDOOOPS0AA: Serial: 1002

        Measurement SW: DASYS, V5.0 Build 120; SEMCAD X Version 13.4 Build 45


Pin = 250 mW; d = 10 mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 93.7 V/m; Power Drift = —0.00384 dB
Peak SAR (extrapolated) = 26.8 W/kg
SAR(1 g) = 13.3 mW/g; SAR(10 g) = 6.24 mW/g
Maximum value of SAR (measured) = 16.5 mW/g




          —20




                     0 dB = 16.5mW/g


Certificate No: D2450V2—716_Mar09                         Page 8 of 9


Impedance Measurement Plot for Body TSL


                                                         10 Man 2009     @9:52:25
CHI) sii     1 U FS          4: 50,.232a   4.2798 0   277.99 pH         2 450.000 000 MHz


*

Del


Cor
                                              V




Av
169




CH2




Cor




Av
16 2




           START 2 250.000 000 MHz                                STOP 2 650,000 000 MHz




Certificate No: D2450V2—716_Mar09                       Page 9 of 9