RF Exposure Evaluation

FCC ID: TLZ-BT076

RF Exposure Info

Download: PDF
FCCID_1522399

                           RF Exposure Evaluation

Evaluate for portable condition.

output < 60/f(GHz) mW, SAR evaluation is generally not required

Operating Frequency                  Output Power                 Output Power
                                                                                 60/f(GHz)
       (GHz)                            (dBm)                        (mW)

         2.4                             1.49                        1.409          25



output < 60/f(GHz) mW

1.409mW< 25mW

Thus No SAR is required for Portable used condition


FCC TEST REPORT                                                                   Report No. : FR122348


1. Maximum Permissible Exposure
1.1. Applicable Standard
    Systems operating under the provisions of this section shall be operated in a manner that ensures that
    the public is not exposed to radio frequency energy levels in excess limit for maximum permissible
    exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been
    defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user
    and the device.
    (A) Limits for Occupational / Controlled Exposure
                                                                                              Averaging Time
      Frequency Range         Electric Field        Magnetic Field      Power Density (S)
                                                                                                |E|²,|H|² or S
            (MHz)           Strength (E) (V/m) Strength (H) (A/m)           (mW/ cm²)
                                                                                                  (minutes)
            0.3-3.0                 614                   1.63                  (100)*                 6
            3.0-30                1842 / f              4.89 / f              (900 / f)*               6
            30-300                  61.4                 0.163                    1.0                  6
          300-1500                                                              F/300                  6
        1500-100,000                                                               5                   6
    (B) Limits for General Population / Uncontrolled Exposure
                                                                                              Averaging Time
      Frequency Range         Electric Field        Magnetic Field      Power Density (S)
                                                                                                |E|²,|H|² or S
            (MHz)           Strength (E) (V/m) Strength (H) (A/m)           (mW/ cm²)
                                                                                                 (minutes)
           0.3-1.34                 614                  1.63                   (100)*                30
           1.34-30                 824/f                2.19/f                 (180/f)*               30
            30-300                  27.5                0.073                     0.2                 30
          300-1500                                                             F/1500                 30
        1500-100,000                                                              1.0                 30
    Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

                30  P  G                                                  E2
    E (V/m) =                                Power Density:   Pd (W/m²) =
                    d                                                       377
    E = Electric field (V/m)
    P = Peak RF output power (W)
    G = EUT Antenna numeric gain (numeric)
    d = Separation distance between radiator and human body (m)
    The formula can be changed to

    Pd =
           30  P  G
            377  d 2
    From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the
    gain of the used antenna, the RF power density can be obtained.

1.3. Calculated Result and Limit
    Antenna Type : Printed Antenna
    Max Conducted Power for Bluetooth: 1.49dBm
                                                                                                    Power
      Test        Min. User                                    Conducted Power      Conducted
                                Gain (dBi)    Numeric Gain                                         Density
      Mode      Distance (cm)                                      (dBm)            Power (mW)
                                                                                                  (mW/cm2)
      2.4G              20          2           1.584893             1.87             1.5382        0.0031




                                                                                     Page No.   : 2 of 2
                                                                                     FCC ID     : TLZ-BT076



Document Created: 2011-08-12 08:36:36
Document Modified: 2011-08-12 08:36:36