Test Report

FCC ID: TKWBIOSTATIONRFOC

Test Report

Download: PDF
FCCID_767437

Test Report for FCC

           Report Number             ESTF150703-004

                 Company name        Suprema Inc.
                                     16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam,
  Applicant         Address          Gyeonggi, 463-863 Korea
                   Telephone         82-31-783-4505

                  Product name       FINGERPRINT SYSTEM

   Product         Model No.          BioStation(BSR-OC)       Manufacturer            Suprema Inc.

                    Serial No.               NONE            Country of origin             Korea

  Test date            17-Jan-07       ~     28-Feb-07         Date of issue             2-Mar-07

    Testing                                     ESTECH. Co., Ltd.
   location                 97-1 Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea

  Standard                           FCC Part 15 Subpart C , ANSI C 63.4 2003

 Measurement facility registration number         94696

  Tested by                   Engineer J.H.Kim                    (Signature)

Reviewed by            Manager Engineer J.M.Yang                  (Signature)

Abbreviation     OK, Pass = Passed, Fail = Failed, N/A = not applicable

  * Note
  - This test report is not permitted to copy partly without our permission
  - This test result is dependent on only equipment to be used
  - This test result based on a single evaluation of one sample of the above mentioned




               Report Number : ESTF150703-004 , Web : www. estech. co. kr       Page 1 of 14


Contents

 1. Laboratory Information …………………………………………………………………………                                  3

 2. Description of EUT ………………………………………………………………………………                                    4

 3. Test Standards …………………………………………………………………………………… 5

 4. Measurement condition ………………………………………………………………………… 6

 5. Measurement of radiated emission …………………………………………………………… 8

   5.1 Radiated emission limits, general requirements ………………………………………… 8

   5.2 Measurement equipment …………………………………………………………………… 8

   5.3 Environmental conditions …………………………………………………………………… 8

   5.4 Test data ……………………………………………………………………………………… 9

 6. Measurement of conducted emission ………………………………………………………… 10

   6.1 Measurement equipment …………………………………………………………………… 10

   6.2 Environmental conditions …………………………………………………………………… 10

   6.3 Test data ……………………………………………………………………………………… 11

 7. Photographs of test setup ……………………………………………………………………… 12

 8. Photographs of EUT ……………………………………………………………………………… 14




 Appendix 1. Spectral diagram




             Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 2 of 14


1. Laboratory Information
1.1 General
 This EUT (Equipment Under Test) has been shown to be capable of compliance with the applicable
 technical standards and is tested in accordance with the measurement procedures as indicated in
 this report.ESTECH Lab attests to accuracy of test data. All measurement reported herein were
 performed by ESTECH Co., Ltd.
 ESTECH Lab assume full responsibility for the completeness of these measurements and vouch for
 the qualifications of all persons taking them.

1.2 Test Lab.

 Corporation Name : ESTECH Co. Ltd

 Head Office : Rm 1015, World Venture Center II, 426-5, Gasan-dong, Geumcheon-gu, Seoul, Korea
            (Safety & Telecom. Test Lab)

 EMC Test Lab : 58-1 Osan-Ri, GaNam-Myon, YeoJoo-Gun, KyungKi-Do, Korea
              97-1 Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea


1.3 Official Qualification(s)

 MIC : Granted Accreditation from Ministry of Information & Communication for EMC, Safety
      and Telecommunication
 KOLAS : Accredited Lab By Korea Laboratory Accreditation Schema base on CENELEC
       requirements
 FCC : Filed Laboratory at Federal Communications Commission
 VCCI : Granted Accreditation from Voluntary Control Council for Interference from ITE




              Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 3 of 14


2. Description of EUT
2.1 Summary of Equipment Under Test
Product               :   FINGERPRINT SYSTEM
Model Number          :   BioStation(BSR-OC)
Serial Number         :   NONE
Manufacturer          :   Suprema Inc.
Country of origin     :   Korea
Operating Frequency   :   125KHz
Antenna Type          :   Loop Coil
Data rates            :   1kbps
Modulation Type       :   ASK
Channel Spacing       :   1
Rating                :   AC input100 ~250 VAC,0.8A, 50/60Hz , DC output 12V---2.5A
Receipt Date          :   15-Jan-07
X-tal lists           :   6MHz,12MHz,20MHz

2.2 General descriptions of EUT




             Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 4 of 14


3. Test Standards

Test Standard : FCC PART 15 (2006)
  This Standard sets out the regulations under which an intentional, unintentional, or incidental

  radiator may be operated without an individual license. It also contains the technical specifications,
  administrative requirements and other conditions relating to the marketing of Part 15 devices.

Test Method : ANSI C 63.4 (2003)
  This standard sets forth uniform methods of measurement of radio-frequency (RF) signals and
  noise emitted from both unintentional and intentional emitters of RF energy in the frequency range 9
  kHz to 40 GHz. Methods for the measurement of radiated and AC power-line conducted radio noise
  are covered and may be applied to any such equipment unless otherwise specified by individual
  equipment requirements. These methods cover measurement of certain decides that deliberately
  radiate energy, such as intentional emitters, but does not cover licensed transmitters. This standard
  is not intended for certification/approval of avionic equipment or for industrial, scientific, and
  medical (ISM) equipment These method apply to the measurement of individual units or systems
  comprised of multiple units


Summary of Test Results
                     Applied Satandard : 47 CFR Part 15, Subpart C
  Standard              Test Type                Result                  Remark                   Limit

   15.207     AC Power Conducted Emission        Pass             Meet the requirement

   15.205            Restricted bands            Pass             Meet the requirement

   15.209           Radiated Emission            Pass             Meet the requirement




               Report Number : ESTF150703-004 , Web : www. estech. co. kr         Page 5 of 14


4. Measurement Condition
4.1 EUT Operation.

     The EUT is Power ON and operate continuously in transmitting.


4.2 Configuration and Peripherals




            Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 6 of 14


4.3 EUT and Support equipment
                                                                                                            Remark
     Equipment Name                   Model Name                       S/N               Manufacturer
                                                                                                           (FCC ID)

    FINGERPRINT SYSTEM             BioStation(BSR-OC)                 NONE              Suprema Inc.         EUT

         Adapter                         PW127                        NONE            AULT Korea Corp.




4.4 Cable Connecting
                 Start Equipment                              End Equipment             Cable Standard
                                                                                                           Remark
          Name                      I/O port            Name              I/O port    Length    Shielded

    FINGERPRINT SYSTEM              Power               Adapter               -         2           No




              Report Number : ESTF150703-004 , Web : www. estech. co. kr             Page 7 of 14


5. Measurement of radiated disturbance
   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter Open
   test site. The table was rotated 360 degrees to determine the position of the highest radiation.Then
   antenna is a loop antenna is fixed at one meter above the ground to determine the maximum value
   of the field strength. Both parallel and perpendicular of the antenna are set to make the
   measurement. For each suspected emission, the EUT was arranged to its worst case and then the
   table was turned from 0 degrees to 360 degrees to find the maximum reading. The test-receiver
   system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
5.1 Radiated emission limits, general requirements
   Except as provided elsewhere in this Subpart, the emissions from an intentional radiator

   shall not exceed the field strength levels specified in the following table:
                   Frequency                           Field Strength(microvolt/meter)            Distance(meter)
                  0.009-0.490                                    2400/F(KHz)                            300
                  0.490-1.705                                   24000/F(KHz)                            30
                   1.705-30                                           30                                30
                      30-88                                         100**                                3
                     88-216                                         150**                                3
                    216-960                                         200**                                3
                   Above 960                                         500                                 3

   ** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
   Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz.
   However, operation within these frequency bands is permitted under other sections of this Part, e.g., Sections
   15.231 and 15.241

5.2 Measurement equipments
                                                                                                        Next
       Equipment Name                 Type             Manufacturer                Serial No.
                                                                                                  Calibration date
      Spectrum Analyzer             R3261C              ADVANTEST                  61720116         2007. 4. 19
        Loop Antenna               HFH2-Z2          ROHDE&SCHWARZ                 8931031024            2007.10.08
           Amplifier                 8447F                   HP                   2805A02972            2007. 6. 26
          Turn Table                  2087                  EMCO                     2129                   -
         Antenna Mast              2070-01                  EMCO                  9702-203                  -
     ANT Mast Controller              2090                  EMCO                     1535                   -
     Turn Table Controller            2090                  EMCO                     1535                   -
5.3 Environmental Condition
   Test Place                  : Open site(3m)
   Temperature (°C)            :8 ℃
   Humidity (%)                : 37 %

                Report Number : ESTF150703-004 , Web : www. estech. co. kr               Page 8 of 14


5.4 Test data

Test Date : 21-Feb-07                                       Measurement Distance :           3m
                                                Correction Factor                Result Value
Frequency    Reading     Position     Height
  (MHz)       (dB㎶)       (V/H)        (m)     Ant Factor     Cable     Limit   Result          Margin
                                                  (dB)        (dB)    (dB㎶/m) (dB㎶/m)            (dB)
                                    Emissions(Average Detector)
  0.123      59.30          H          1.0      19.35         0.6        105.8       79.25      -26.56
  0.370      25.50          H          1.0      19.28         0.6        96.2        45.38      -50.86




            H : Horizontal, V : Vertical
            *Below 30Mhz was applied Average Detector.
            *There is no found Restricted bands.
Remark      *Emission above 30MHz were reported in Report No.ESTF150701-011
            *The 300m limit was converted to 3m Limit using square factor(x) as it was found by
            measurements as follows;
            3 m Limit(dBuV/m) = 20log(2400/F(KHz))+40log(300/3)= 20log(2400/125)+40log(300/3)
            = 25.67+80




            Report Number : ESTF150703-004 , Web : www. estech. co. kr      Page 9 of 14


6. Measurement of conducted disturbance
   The continuous disturbance voltage of AC Mains in the frequency from 0.15 to 30 MHz was
   measured in accordance to FCC Part 15 (2006). The test setup was made according to ANSI C
   63.4 (2003) in a shielded. The EUT was placed on a non-conductive table at least 80 above the
   ground plan. A grounded vertical reference plane was positioned in a distance of 40cm from the
   EUT. The distance from the EUT to other metal surfaces was at least 0.8m. The EUT was only
   earthen by its power cord through the line impedance stabilizing network. The power cord has
   been bundled to a length of 1.0m.. The test receiver with Quasi Peak detector complies with CISPR
   16.


6.1 Measurement equipments

                                                                                       Next Calibration
    Equipment Name                Type           Manufacturer          Serial No.
                                                                                            date
             LISN             ESH3-Z5          Rohde & Schwarz        838979/010          2007. 2. 27
             LISN            NNLA8120A           Schwarzbeck            8120161           2007. 2. 27
     TEST Receiver              ESPI7          Rohde & Schwarz          100185            2007. 8. 24
         Pulse Limiter         ESH3Z2          Rohde & Schwarz           NONE             2007. 6. 15


6.2 Environmental Condition
   Test Place            : Shield Room
   Temperature (°C)      : 20 ℃
   Humidity (%)          : 40 %




                Report Number : ESTF150703-004 , Web : www. estech. co. kr    Page 10 of 14


6.3 Test data
Test Date :        17-Jan-07
                 Correction Factor                  Quasi-peak Value                   Average Value
 Frequency                            Line
   (MHz)          Lisn      Cable    (H/N)      Limit   Reading    Result      Limit     Reading       Result
                  (dB)      (dB)               (dB㎶)     (dB㎶)     (dB㎶)      (dB㎶)       (dB㎶)         (dB)
    0.15         0.10        0.0      N        66.00     49.35     49.45      56.00
    0.20         0.10        0.0      H        63.53     42.35     42.48      53.53       33.82        33.95

    0.27         0.10        0.1      N        61.15     50.30     50.48      51.15       32.92        33.10
    0.34         0.10        0.1      N        59.30     49.92     50.14      49.30       38.37        38.59
    0.40         0.10        0.2      H        57.79     55.01     55.26      47.79       32.79        33.04

    0.47         0.10        0.2      H        56.48     55.70     55.99      46.48       35.91        36.20

    0.94         0.10        0.2      N        56.00     48.42     48.72      46.00       41.27        41.57
    2.89         0.13        0.3      N        56.00     49.99     50.42      46.00       39.29        39.72
    2.93         0.13        0.3      H        56.00     49.83     50.26      46.00       40.10        40.53

    3.88         0.16        0.3      N        56.00     48.85     49.31      46.00       39.03        39.49

    3.90         0.16        0.3      H        56.00     51.90     52.36      46.00       38.07        38.53
    4.87         0.20        0.3      H        56.00     44.02     44.52      46.00       36.47        36.97

    5.80         0.22        0.3      N        60.00     49.51     50.07      50.00
    6.80         0.25        0.4      N        60.00     49.49     50.12      50.00       23.18        23.82

    7.81         0.26        0.5      N        60.00     49.47     50.19      50.00
    9.49         0.29        0.6      H        60.00     49.45     50.31      50.00

   11.31         0.33        0.7      H        60.00     49.43     50.41      50.00
   12.05         0.34        0.7      H        60.00     49.41     50.43      50.00



  Remark                                     H : Hot Line, N : Neutral Line




              Report Number : ESTF150703-004 , Web : www. estech. co. kr      Page 11 of 14


7. Photographs of test setup
7.1 Setup for Radiated Test (below 30MHz)
                                          [ Front ]




                                          [ Rear ]




          Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 12 of 14


7.2 Setup for Conducted Test : 0.15 ~ 30 MHz
                                         [ Front ]




                                         [ Rear ]




         Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 13 of 14


8. Photographs of EUT
                                        [ Front ]




                                        [ Rear ]




        Report Number : ESTF150703-004 , Web : www. estech. co. kr   Page 14 of 14


Appendix 1. Spectral diagram
             *HOT
                                          RBW    9 kHz
                                          MT     1 s
                         Att 10 dB AUTO   PREAMP OFF
dBµV    90                 1 MHz                         10 MHz
                              LIMIT CHECK     PASS

        80
                                                                           SGL
1 PK
CLRWR
        70
2 AV
CLRWR   EN55022Q
                                                                           TDF
        60

        EN55022A
        50                                                                 PRN




        40



        30



        20



        10


        0

        150 kHz                                                   30 MHz



Comment: BioStation(BSR-OC)  HOT
Date:      17.JAN.2007 18:31:13


             *NEUTRAL
                                          RBW    9 kHz
                                          MT     1 s
                         Att 10 dB AUTO   PREAMP OFF
dBµV    90                 1 MHz                         10 MHz
                              LIMIT CHECK     PASS

        80
                                                                           SGL
1 PK
CLRWR
        70
2 AV
CLRWR   EN55022Q
                                                                           TDF
        60

        EN55022A
        50                                                                 PRN




        40



        30



        20



        10


        0

        150 kHz                                                   30 MHz



Comment: BioStation(BSR-OC)  NEUTRAL
Date:      17.JAN.2007 18:36:38



Document Created: 2007-03-02 18:11:11
Document Modified: 2007-03-02 18:11:11