TE7WR1043NDV4- RF EXPOSURE

FCC ID: TE7WR1043NDV4

RF Exposure Info

Download: PDF
FCCID_2919287

                    Test Report No.: FS151030N028



                                    RF EXPOSURE REPORT
    Applicant                        TP-LINK TECHNOLOGIES CO., LTD.
                                     Building 24(floors1, 3, 4, 5) and 28(floors1-4) Central Science and Technology Park,
    Address
                                     Shennan Rd, Nanshan, Shenzhen, China

    Manufacturer or
                                     TP-LINK TECHNOLOGIES CO., LTD.
    Supplier

                                     Building 24(floors1, 3, 4, 5) and 28(floors1-4) Central Science and Technology Park,
    Address
                                     Shennan Rd, Nanshan, Shenzhen, China

    Product                          450Mbps Wireless N Gigabit Router

    Brand Name                       TP-LINK

    Model                            TL-WR1043ND

    Additional Model &
                                     N/A
    Model Difference

    Date of tests                    Dec.10, 2015 ~ Dec. 24, 2015

         FCC Part 2 (Section 2.1091)
         KDB 447498 D01
         IEEE C95.1

    CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                           Tested by Harry Li                                                              Approved by Chris Chen
                  Project Engineer/ EMC Department                                                  Assistant Manager / EMC Department




                                                                                                                 Date: Dec. 24, 2015
    This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
    only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
    report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
    unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
    provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
    however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
    shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
    mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification




                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                        Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                                     Email: customerservice.dg@cn.bureauveritas.com
                                                                           Page 1 of 6                                                              Report Version 1


                Test Report No.: FS151030N028

                                          Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FS151030N028


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED
    FS151030N028             Original release                                                         Dec. 24, 2015




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FS151030N028

   1. CERTIFICATION

                     PRODUCT:       450Mbps Wireless N Gigabit Router

                BRAND NAME:         TP-LINK

                   MODEL NO.:       TL-WR1043ND
      ADDITIONAL MODEL:             N/A
                 FCC ID:            TE7WR1043NDV4
               TEST SAMPLE:         ENGINEERING SAMPLE

                   APPLICANT:       TP-LINK TECHNOLOGIES CO., LTD.

               TESTED DATE:         Dec. 24, 2015

                 STANDARDS:         FCC Part 2 (Section 2.1091)
                                    KDB 447498 D01

                                    IEEE C95.1




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 6                                                    Report Version 1


                Test Report No.: FS151030N028

   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
                                                                          2
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm )                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm


   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 6                                                      Report Version 1


    B U R E A U
    V E R I TA S
                    Test Report No.: FS151030N028


   5. ANTENNA GAIN
         The antennas provided to the EUT, please refer to the following table:
              Transmitter       peak Gain |(Total Gain             Antenna
                   Circuit          (dBi)          (dBi)             Type
                   Chain 0           5.0                       Dipole Antenna

                   Chain 1           5.0           9.77        Dipole Antenna

                   Chain 2           5.0                       Dipole Antenna

           Note: Total Gain=5.0+10log(N=3)=5.0+(4.77)=9.770Bi



   6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER


     FREQUENCY               max power           ANIENNA              DISTANCE               Eh                      LIMIT
       BAND                     (mw)               GAIN                 (cm)                DENSITY                (mW/em?)
        (MHz)                                      (dBi)                                    (mW/ecm*)
    WLAN 2.4GHz               663.943                  5                    20                0.660                     1.0




    ——— END ———




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                            Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 6 of 6                                                    Report Version 1



Document Created: 2016-01-08 14:56:51
Document Modified: 2016-01-08 14:56:51

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC