MPE test report_rev1

FCC ID: TE7WCS200

RF Exposure Info

Download: PDF
FCCID_3904042

                                                     ISSUED BY
                                                     Shenzhen BALUN Technology Co., Ltd.                                            Lm

                                                                                              FOR
                                                             10W Wireless Fast Charging Station

                                                                                         ISsSUED TO
                                                                           TP—Link Technologies Co., Ltd.

                                                    Building 24 (floors 1,3,4,5) and 28 (floors1—4) Central Science and
                                                    Technology Park, Shennan Rd, Nanshan, Shenzhen, China




                                                              s Cllaly o BL—SZ1830386—702
                                                                SUAmmISH         10W Wireless Fast Charging Station
                                                           [VfelelAMNETuTS® TL—WCS200
                                                           Brand Name: SS
                                                          ICS@seQleETe® 47 CFR Part 1.1307
                                                                                 47 CFR Part 1.1310
                                                                  [SeleifpH TEZWCS200


                                                      Test Conclusion: MaEES
                          (Chief Engineer)                     RCS@PEICH Apr. 15, 2018 ~Apr. 13, 2018
                Date]bv\‘_'&w&                            pEpCEATe Jun. 25, 2018

  NOTE: This test report can be duplicated completelyfor the legal use with the approval ofthe applicant;it shall not be reproduced except in
 Jull, without the written approval ofShenzhen BALUN Technology Co., Ltd. BALUN Laboratory. Any objections should be raised within thirty
  daysfromthe date ofissue. To validate the report, please visit BALUN website.


Block B, 1st FL,Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong, P. R. China 518055
TEL: +86—755—66850100, FAX: +86—755—61824271

www.baluntek.com


                                                                                                            Report No.: BL-SZ1830386-702


                                                               Revision History
               Version               Issue Date                       Revisions Content
               Rev. 01               May 29, 2018                     Initial Issue
               Rev. 02               Jun. 25, 2018                    Update the Operating Mode on page 5

                                                       TABLE OF CONTENTS
1   GENERAL INFORMATION ..................................................................................................................... 3

         1.1 Identification of the Testing Laboratory ...................................................................................... 3

         1.2 Identification of the Responsible Testing Location ..................................................................... 3

         1.3 Test Environment Condition ....................................................................................................... 3

         1.4 Announce ................................................................................................................................... 3

2   PRODUCT INFORMATION ..................................................................................................................... 4

         2.1 Applicant Information.................................................................................................................. 4

         2.2 Manufacturer Information ........................................................................................................... 4

         2.3 Factory Information .................................................................................................................... 4

         2.4 General Description for Equipment under Test (EUT) ............................................................... 4

         2.5 Ancillary Equipment.................................................................................................................... 4

         2.6 Technical Information ................................................................................................................. 5

3   STANDARD INFORMATION ................................................................................................................... 6

         3.1 Test Standard ............................................................................................................................. 6

         3.2 Radiofrequency Radiation Exposure Limit ................................................................................. 6

4   TEST SETUP........................................................................................................................................... 7

         4.1 Test Setup Photo........................................................................................................................ 7

         4.2 Measurement procedure ............................................................................................................ 7

         4.3 Mobile Condition......................................................................................................................... 7

         4.4 Test Equipment .......................................................................................................................... 7

         4.5 Test Configuration ...................................................................................................................... 8

5   TEST RESULT ........................................................................................................................................ 9

         5.1 E-field ......................................................................................................................................... 9

         5.2 H-field ......................................................................................................................................... 9

6   Test Conclusion ....................................................................................................................................... 9

         6.1 E-field ......................................................................................................................................... 9

         6.2 H-field ......................................................................................................................................... 9


                                                                           2/9


                                                                            Report No.: BL-SZ1830386-702


1 GENERAL INFORMATION
1.1 Identification of the Testing Laboratory
       Company Name              Shenzhen BALUN Technology Co., Ltd.
                                 Block B, 1st FL, Baisha Science and Technology Park, Shahe Xi
       Address                   Road, Nanshan District, Shenzhen, Guangdong Province, P. R.
                                 China.
       Phone Number              +86 755 6685 0100
       Fax Number                +86 755 6182 4271

1.2 Identification of the Responsible Testing Location
       Test Location             Shenzhen BALUN Technology Co., Ltd.
                                 Block B, 1st FL, Baisha Science and Technology Park, Shahe Xi
       Address                   Road, Nanshan District, Shenzhen, Guangdong Province, P. R.
                                 China.
                                 The laboratory has been listed by Industry Canada to perform
                                 electromagnetic emission measurements. The recognition numbers
                                 of test site are 11524A-1.
                                 The laboratory has been listed by US Federal Communications
       Accreditation
                                 Commission to perform electromagnetic emission measurements.
       Certificate
                                 The recognition numbers of test site are 832625.
                                 The laboratory is a testing organization accredited by China National
                                 Accreditation Service for Conformity Assessment (CNAS) according
                                 to ISO/IEC 17025. The accreditation certificate number is L6791.
                                 All measurement facilities used to collect the measurement data are
                                 located at Block B, FL 1, Baisha Science and Technology Park,
       Description
                                 Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province,
                                 P. R. China 518055

1.3 Test Environment Condition
       Ambient Temperature       21 to 23 ℃
       Ambient Relative
                                 40 to 50%
       Humidity
       Ambient Pressure          100 to 102 KPa

1.4 Announce
   (1) The test report reference to the report template version v1.2.
   (2) The test report is invalid if not marked with the signatures of the persons responsible for preparing and
       approving the test report.
   (3) The test report is invalid if there is any evidence and/or falsification.
   (4) The results documented in this report apply only to the tested sample, under the conditions and modes
       of operation as described herein.
   (5) This document may not be altered or revised in any way unless done so by BALUN and all revisions are
       duly noted in the revisions section.
   (6) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes
       without prior written approval from the laboratory.


                                                    3/9


                                                                           Report No.: BL-SZ1830386-702


2 PRODUCT INFORMATION
2.1 Applicant Information
         Applicant              TP-Link Technologies Co., Ltd.
                                Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and
         Address
                                Technology Park, Shennan Rd, Nanshan, Shenzhen, China


2.2 Manufacturer Information
        Manufacturer            TP-Link Technologies Co., Ltd.
                                Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and
        Address
                                Technology Park, Shennan Rd, Nanshan, Shenzhen, China


2.3 Factory Information
        Factory                 N/A
        Address                 N/A


2.4 General Description for Equipment under Test (EUT)
         EUT Type               10W Wireless Fast Charging Station
         Model Name Under
                                TL-WCS200
         Test
         Series Model Name      N/A
         Description of Model
                                N/A
         Name Differentiation
         Hardware Version       N/A
         Software Version       N/A
         Network and Wireless
                                N/A
         connectivity


2.5 Ancillary Equipment
Note: Not application.




                                                   4/9


                                                                               Report No.: BL-SZ1830386-702

2.6 Technical Information
The requirement for the following technical information of the EUT was tested in this report:

        Operating Mode             110.5kHz~205kHz
        Antenna Type               Coil Antenna
        About Product              The EUT only support the QI technology.
        Exposure Category          General Population/Uncontrolled exposure
        EUT Stage                  Mobile Device
                                   Type
        Product
                                       Production unit                     Identical prototype




                                                         5/9


                                                                                  Report No.: BL-SZ1830386-702


3 STANDARD INFORMATION
3.1 Test Standard
         No.              Identity          Document Title
          1         47 CFR Part 1           Practice and Procedure
                                            RF Exposure Considerations for Low Power Consumer
          2       KDB 680106 D01
                                            Wireless Power Transfer Applications


3.2 Radiofrequency Radiation Exposure Limit
              Frequency              Electric field          Magnetic field      Power        Averaging
                range                  strength                strength          density        time
                (MHz)                   (V/m)                   (A/m)          (mW / cm 2)    (minutes)
                                      (A) Limits for Occupational/Controlled Exposure
               0.3-3.0                   614                       1.63            *100           6
               3.0-30                   1842/f                   4.89/f           *900/f2         6
               30-300                    61.4                    0.163              1.0           6
              300-1,500                                                            f/300          6
          1,500-100,000                                                                 5         6
                                 (B) Limits for General Population/Uncontrolled Exposure
               0.3-1.34                  614                       1.63            *100           30
               1.34-30                   824/f                   2.19/f           *180/f2         30
               30-300                    27.5                    0.073              0.2           30
              300-1,500                                                           f/1500          30
          1,500-100,000                                                             1.0           30
         f = frequency in MHz * = Plane-wave equivalent power density


NOTE:
General Population/Uncontrolled Exposure: Locations where there is the exposure of individuals who have no
knowledge or control of their exposure. General population/uncontrolled exposure limits are applicable to situations
in which the general public may be exposed or in which persons who are exposed as a consequence of their
employment may not be made fully aware of the potential for exposure or cannot exercise control over their
exposure. Members of the general public would come under this category when exposure is not employment-
related; for example, in the case of a wireless transmitter that exposes persons in its vicinity.

Occupational/Controlled Exposure: Locations where there is exposure that may be incurred by persons who
are aware of the potential for exposure. In general, occupational/controlled exposure limits are applicable to
situations in which persons are exposed as consequence of their employment, who have been made fully aware
of the potential for exposure and can exercise control over their exposure. This exposure category is also
applicable when the exposure is of a transient nature due to incidental passage through a location where the
exposure levels may be higher than the general population/uncontrolled limits, but the exposed person is fully
aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by
some other appropriate means.




                                                             6/9


                                                                                   Report No.: BL-SZ1830386-702


4 TEST SETUP
4.1 Test Setup Photo
Maximum E-field and H-field measurements were made on each of five sides of the EUT that could come in
contact with a user. The five sides are defined as follows: Top (A), Left (B), Bottom (C), Right (D), and Front
(E). Refer to the test position diagram below.




4.2 Measurement procedure
1.   The RF exposure test was performed in anechoic chamber.
2.   The measurement probe was placed at test distance (10 cm) which is between the edge of the charger and
     the geometric center of probe.
3.   The highest emission level was recorded and compared with limit as soon as measurement of each points (A,
     B, C, D, E, F) were completed.
4.   The EUT was measured according the dictates of KDB 680106 D01v02.


4.3 Mobile Condition
                         Probe                       Condition                      Test Distance (cm)
                         E-field                      Mobile                               10
                         H-field                      Mobile                               10




4.4 Test Equipment
           Description             Manufacturer    Model              Serial No.           Cal. Date      Cal. Due
          E-field Probe               Narda        EP601             511WX51129           2016.05.13     2017.05.12
          H-field Probe             Schaffner      EMC-20              1324.11            2016.05.13     2017.05.12
       Anechoic Chamber            RAINFORD       9m*6m*6m               N/A              2016.03.28     2017.03.27




                                                        7/9


                                                                           Report No.: BL-SZ1830386-702

4.5 Test Configuration
To check all kinds of possible modes, the EUT was evaluated with appropriate client and under each charging
condition as the below table:

          Test Mode
             NO.                                         Description
                                         The EUT was powered on and there is no client device
              1           Idle Mode
                                         attached with the EUT.
                                         The EUT was charging the client device which has Less than
              2        Charging Mode
                                         1 % of battery.
                                         The EUT was charging the client device which has Less than
              3        Charging Mode     50 % of battery.
                                         The EUT was charging the client device which has 100 % of
              4        Charging Mode     battery.




                                                     8/9


                                                                                Report No.: BL-SZ1830386-702


5 TEST RESULT
5.1 E-field
                                                           EUT Edges
         Distance     Test           A              B             C       D             E       Limit
           (cm)       Mode         (V/m)          (V/m)         (V/m)   (V/m)         (V/m)     (V/m)
                         1         11.15          13.35         10.46   10.57         21.06
                         2         11.26          13.52         10.58   10.75         21.42
            10                                                                                  614.0
                         3         10.28          12.25         9.66    9.58          20.16
                         4         10.95          12.77         9.85    10.11         20.25


5.2 H-field
                                                           EUT Edges
         Distance     Test           A              B             C       D             E       Limit
           (cm)       Mode         (A/m)          (A/m)         (A/m)   (A/m)         (A/m)     (A/m)
                         1         0.20            0.18         0.15    0.15          0.24
                         2         0.19            0.18         0.15    0.14          0.25
            10                                                                                   1.63
                         3         0.19            0.16         0.12    0.14          0.24
                         4         0.18            0.17         0.12    0.13          0.23



6 Test Conclusion
6.1 E-field
                                       EUT Edge
                                                                Limit     30% Limit
        Distance     Worst-case              E                                                Verdict
                                                                (V/m)       (V/m)
          (cm)       Test Mode             (V/m)
            10               2             21.42                614.0       184.2             Pass


6.2 H-field
                                       EUT Edge
                                                                Limit     30% Limit
        Distance     Worst-case              E                                                Verdict
                                                                (A/m)       (A/m)
          (cm)       Test Mode             (A/m)
            10               2             0.25                 1.63           0.49           Pass


The E-field and H-field data shown in this report show that the EUT is compliant with the 30% of the MPE limits.


                                             --END OF REPORT--




                                                          9/9



Document Created: 2018-06-25 14:41:20
Document Modified: 2018-06-25 14:41:20

© 2024 FCC.report